ML18193A662
| ML18193A662 | |
| Person / Time | |
|---|---|
| Site: | Palo Verde (NPF-041, NPF-051, NPF-074) |
| Issue date: | 07/12/2018 |
| From: | Arizona Public Service Co |
| To: | Office of Nuclear Reactor Regulation |
| References | |
| Download: ML18193A662 (1) | |
Text
NATURAL GAMMA LOG
INCREASING RADIATION~
BAS I C SO I L PROPERTI ES LITHOLOGIC DATA PALEO-CARBONATE MAGNETIC DESCRIPTIONS UNITS L CONTENT POLARITY COUNTS PER SECOND 80 100 120 140 160 180 200 Pl go 90 100 10 60 120 ELEY-9/8' 04 POSITIVE e NEGATIVE WEAEURED WATER LEVEL 90 77 63 SE 93 97 79 94 97
~
u 4
~
4
~
4
~
4
~
20 40 60 eo 100 120
SA/VDYSILT AND 5ILTYSAIVDI fhIL SM),b own,SO/t to Shit, d yiocccvs ono/ g o e/ fo sys SILTYSAAIO,(SM), b o n sub.
angular, med m dc se/
acafts ed ca/she nodulea
SA/VDY SIL T fM/J brown very Shff to bord dry occas anol tl m sons d cloy lenses SAAIL>> CLAVAND SANDV SILT/
j(CL MLAbrown, ve y util/.
o stl o camonal coi che nodules SIL 7 Y CIA Y, (CL-CHA6 o, ve y sfif/, mo st, Mn specks; cal ckv nod /ss SILTV'AIVD,(SM),6 o n
5/LTI CLAY,(CL-CHJ,brow st ff,ma sf/ streaks or cn/
ne I occns ones/ sandy s it hor ons f3 10 51 46 SB TS BD 55 (B/0 sw 100 105 99 14 e
LST 93 74 99
~ ~
r
SA AIDY 67L T VVITH CL A Y,(SM).
b own, veny stiff, mors>, caliche streaks and nodules 165 u
~
g ISO 19 EE 99 97 SILTYCLAY,(CL-CH),r d-bna vs y st f/ mo st; Mn np eke i caliche nodules, loco/i ed ncreasee in sa d conte I R zoe 8
Tos 240
~
~
260
~
~
260 93 100 00 33 9(s
++4+
+~+ 3~
SILTY SAAID A/VD5/LTY CRAYEL, j(ShfdM/.bvo y d nse mo st, pass ply cemented fo te a/
PORPHI RITIC CA'AAIITE O'AIE/55, 0
jwh fe,ho d, ho/ac ys/o/kne, ph e
tic,hyp domo ph c granu/ar
. directional err lure evpcessed by biohtesl andes fc d ks TD-SSO 360 Seo 400 420 440 seo 300 320 340 SAMPLE LOCATION~
DEPTH (FEET)~
SYM BOL EXPLANATION ENGINEERING PARAMETERS PI plasticity /ndes minus 200 percent passing EOO sieve W/0 pe/can/ moisture Sd d y dens ly SAMPLE TYPE AITu o szz listz/
ASTAI O SSS AsTA/ 0 sss llsti/
ASIA// O ZZ/S-Ti Dave Sample Pitcher Tube Sample AIA Cars,No Indicates
% Recovery Elands d Pane/ anon Test, N olus Asm nisse-st CARBONATE CONTENT No React on 4
Si ghtly /tenet ve Nods otely Reactive
++ Highly Reactive fbassd on sample reochon la a ION h'CI solution/
UNITS Lin'Is column rsfs 7 la generol siroligniphic divisions iden>>fied nilkm the basin ssd msnls PALEOMAGNETIC POLARITY inc/ no/ion ot remnant magne/ic vector in gsnsiol agreemenl wilh ((g I or opposition to I'
I Ihe present magnenc lis/d 8Mognelic vector indelerminofeW depth Poleomognehc
/7 izs Rsviiso/~ /0 listV eleve/ on D E 6 0 R I PT I0 N 5 Lnkslogic descnphons wste comp lsd from gsolog sls field logs, lobaratoty /es/ do/a, ond down-hole geophyscs yield logs were prepared n accordance silk ASTSf D2488-6'9 Clossiiscahons bus/id on laboratory test data oisin accordance with ASTM 024/8T.69. Roc'A'escr plions follow procedures ounined in Ihe OUARTERLY OF THE COLORADO SCHOOL OF MINES, Volume SO, No /
Osscnpnons lor iotarf borings ore based upon cullmgs
- samples, geophys cal logs and drigsrs'comments LOG OF BORING PV-SI