EXPLANATION:

Stratigraphic Unit 0 GEOLOGIC CONTACTS SOIL DESCRIPTIONS Stratigraphic Unit A Ctayey Sand (SC), Silty Sand (SM), Sand and Gravelly Sand (SP-GP), Sifts and Clays (ML and CL);

brown to red. coarse grained horizons dense poorly sorted; angular to subangular very fine to coarse quartz end lithic fragments; cobbles to 10" diameter, fines approximately 12-35%. Fine grained horizons:

low to medium plasticity, stiff to hard, thinly interbedded.

Horizons discontinuous horizontally and verti-cally Locally crossbedded SOLID located withm I inch LONG DASH; located withinld inches re Silty and Sandy Clay (CL), Clayey and Sandy Sgt (ML), Gravelly Sand (SP), Clayey Sand (SC): brown; cease grained horizons are dense, poorly sortedfroorly graded, angular to subangular, very fine to coarw quartz and lithic fragments, gravel to 2" diameter, fines 12%i to 35%. Fine grained horizons low to medium plasticity, stiff to hard. Horizons are discontinuous both horizontally and vertically, nterme-diate contacts gradational. Caliche nodules and root casts are abundant.

Silty Clay (CL), Clayey Silt (ML); brown, low to medium plasticity, dry to moist, stiff to very stiff.

Stratigraphic Unit E

SHORT DASH; located withir3-6 inches HACHURED; located as gradabnal across 6-12 inches Stratigraphic Unit B CONTACT CONCEALED BY ILL xx Btiii Silty Sand (SM), Gravelly Sand (SP), gray to brown, poorly sorted-poorly

graded, angular to sub-

'gular, very fine to coarse quartz and lithic sand, 12% to +25% fines and

<10% to 130% gnvel, dry, loose, non to slightly calcareous, locally cross-bedded.

Silty Clay-Clayey Silt (CL-ML), Sandy Silt (ML), brown,

<10% to 140% sand, low to medium flas-ticity, very stiff to hard, slightly to highly calcareous; lenses of silty sand, caliche nodules.

E Et if Silty Clay and Clayey Silt; (CL and ML), dark reddish

brown,

<10% send, medium to high plas-ticity, very stiff to hard, non to moderately calcareous, occasional caliche nodules, root casts, dark mineral staining.

Clayey Sand (SC), Clayey Sandy Silt (ML); brown to dark reddish brown, low plasticity moist stiff to very stiff, non to slightly calcareous; fine quartz and mica sand 15-50%; discontinuous stringers of silty clay.

C )4 55 SYMBOLS GEOLOGIC SURVEY CONTIBL POINT, Referenced to Anzona State Pine Coordinates GEOLOGIC MAP AREA defmd by control points Stratigraphic Unit C Silty and Sandy Clay (CL), Clayey Silt (ML), Clayey Sand (SC), brown to reddish brown, medium plasticity; very stiff, locally calcareous; 12-> 30 percent fine sand.

Caliche; white, dense, hard, discontinuous. Not exposed in Unit 2.

20 SCALE. I inch 20 feet 40 60 60 Arizona Nuclear Power Project Palo Verde Nuclear Denerating Station Dnita),2& 3 Contour Interval 2 feet AS GRADED GEOLOGIC MAP UNIT 1 CATEGORY 1 EXCAVATION

{Sheet 1 of 7)

Topography by photogrammetic methods from aerial photography; base map supplied by Bechtel Corporation and modified by Fugro, Inc.

Figure 2Z-I September 1,