ML18193A071

From kanterella
Jump to navigation Jump to search
Figure 10.1-3, Heat Balance at Stretch (Vwo) Power
ML18193A071
Person / Time
Site: Palo Verde  
Issue date: 07/12/2018
From:
Arizona Nuclear Power Project
To:
Office of Nuclear Reactor Regulation
References
10.1-3
Download: ML18193A071 (1)


Text

FROM STEAM GENERATORS 18,172 155 W 983 P 1190.2 H

845,859 W 1190.2 H

590,995 W 1149.1 H

483.9 P

969.6 P 00lfl0 17,326,296 W

5829 W 14,264,424 W 1092.3 H

208.4 P

MOISTUR E SEPARATOR 10073 EFF Z

K r 00 ID Dl 0N STEAM REHEATER 26.2 T TD Z

N R DI Cl ID O Cl N

STEAM REHEATER 26.2 T TD 12,458,134 W 1276.5 H

200.1 P

267,007 W 1276.5 H

190.3 P MSV I

11,498 W 1,806,290 W 358.2 H

590,995 W 845,859 W 444.8 H 480.1 P

6 536.6 H 969 9 P PIV = 198.1 CIV FEE DWATER PUMP TURBINE FEEDWATER PUMP 18,171 KW PB = 943,7 EXTRACTION ARRANGEMENT IS SCHEMATIC ONLY 4.0 IN.Hg A 267,007 W 1031.3 H

7 TO STEAM GENERATORS Dl CDN r

Ifl Z

Cl CC Dl0 CD Dl0N 0

Cl ClN r

Dl 0

N N

r ID Dl CI i N

Ift ID HP TURBINE 0

Cl 0

0 r

0N Z

0fl Dl0 DtN ID Z

M N

Dl0 N

r cr Z0 Dl 0

o

  • Kt r

ID tD 0 A

Z Z

O ID Dl ID Ift Dl CO 0oo lfl LP TURBINE Z

CC Cl ClN r0 60 Z

N Dl LP TURBINE o

ClN Nf Z

Z 0IK ID Cl 0 tD N

Z ID ID N0N Z

Z Dl Ifl 0

m or o OI0 LP TURBINE N

ID ClN Z

A 0

ELEP = 1005.7 H

UEEP = 1011.7 H

TURBINE COOLING B WATER 00N 3

N ID 4

STEAM SEAL PACKING EXHAUSTER 1103,0 H

EXPANSION LINE CROSSES SATURATION LINE AT 48.25 P8IA GENERATOR OUTPUT 1,374,011 KW 75 PSIG H2 PRESS 0.90 PF 6776 KWFIXED LOSSES 16882 KWGEN LOSSES BELEP 0 1.5 IN HgA = 941.8 H 9,296,174 W 3.5 IN Hg A CONDENSER 00 CD0 ID CD Cl Dl 12,498,921 W

120.6 F

88.5 H LEGEND:

H ENTHALPY, BTU/LB W -

FLOW, LB/HR P

PRESSURE, PSIA T

TEMPERATURE, clF VALVEBEST POINT NET HEAT RATE TD

- TERMINALDIFFERENCE DC

- DRAIN COOLING MSV

- MAINSTOP VALVE CIV

- COMBINED INTERCEPT VALVE SJAE

- STEAM JET AIR EJECTOR 18,175,655 (1190.2 435.0) 9990 BTU/KWHR 1,374,01 I N

0 453.9 T 435,0 H 12 T 494.4 P TD I

5 412.6 T 389.84 H ST TD 310.9 P

HEATER 5 376.5 T 351.3 H 5T TD 199.4 P

347.2 T 320.5 H FEEDWATER PUMP 1200 P 4H = 3.60 345.4 T 316.9 H 328.7 T 299.5 H 5T 108.4 P TD 293.2 T 262.7 H

5T TD 65,2 P

224.2 T 192.5 H 5T TD 20.5 P

188HI T 156.1 H

9.98 P TD COOLING WATER 465.9 T 15T DC 1,801,423 W 420.6 T 15T DC 3,165,039 W 391.5 T 366.1 H

381.5 F 381.5 T 752,545 W 355.2 H

I-Z 333.7 T IOT DC 478,908 W 298.2 7 IOT Dc 1,330,715 W 229.2 T IOT DC 1,803,695 W DC 2,662,809 W 193.1 T 10T SJAE 427.6 T 405.4 H HEATER 7 HEATER 6 HEATER DRAIN TANK 5,676,735 W 335.2 H 303.2 T 273.0 H HEATER 4 234.2 T 202.7 H HEATER 3 198.1 T 166.2 H HEATER 2 HEATER 1 130.6 T 98.5 H Arizona Nuclear Power Project Palo Verde Nuclear Generating Station Units l, 2 R 3 HEAT BALANCE AT STRETCH (VWO)

POWER Figure 10.1-3 I 0407cl 1 4 26AP4-I I 3