July 16, 2018 MEMORANDUM TO:
Samuel S. Lee, Chief Licensing Branch 1 Division of Licensing, Siting and Environmental Analysis Office of New Reactors FROM:
Prosanta Chowdhury, Project Manager
/RA/
Licensing Branch 1 Division of Licensing, Siting and Environmental Analysis Office of New Reactors
SUBJECT:
SUMMARY
OF THE JUNE 26, 2018, U.S. NUCLEAR REGULATORY COMMISSION CATEGORY 1 PUBLIC TELECONFERENCE WITH NUSCALE POWER, LLC TO DISCUSS STAFF FEEDBACK ON FINAL SAFETY ANALYSIS REPORT TIER 1 AND TIER 2 CHANGES PERTAINING TO METEOROLOGY On June 26, 2018, the U.S. Nuclear Regulatory Commission (NRC) staff held a Category 1 teleconference public meeting with NuScale Power, LLC (NuScale) to discuss staff feedback on NuScale changes to Tier 1 and Tier 2 of the NuScale Final Safety Analysis Report (Agencywide Documents Access and Management System (ADAMS) Accession No. ML18149A404) and NuScales Replacement Response to Request for Additional Information (RAI) No. 9182 (ADAMS Accession No. ML18149A342). The above cited information is related to NuScale Design Certification Application, Chapter 2.3, "Meteorology." One member of the public participated in the meeting.
The public meeting notice can be found in ADAMS under Accession No. ML18176A187. The meeting notice was also posted on the NRC public website. Enclosed is the meeting agenda (Enclosure 1), list of attendees (Enclosures 2), and meeting summary (Enclosure 3).
Docket No.52-048
Enclosures:
- 1. Meeting Agenda
- 2. List of Attendees
- 3. Meeting Summary cc w/encl.: DC NuScale Power, LLC Listserv CONTACT: Prosanta Chowdhury, NRO/DLSE 301-415-1647
MMoore*
PChowdhury DATE 7/10/2018 7/10/2018 7/16/18
U.S. NUCLEAR REGULATORY COMMISSION CATEGORY 1 PUBLIC TELECONFERENCE WITH NUSCALE POWER, LLC TO DISCUSS STAFF FEEDBACK ON FINAL SAFETY ANALYSIS REPORT TIER 1 AND TIER 2 CHANGES PERTAINING TO METEOROLOGY MEETING AGENDA June 26, 2018 The purpose of this public teleconference meeting was for the U.S. Nuclear Regulatory Commission staff to discuss feedback on NuScale Power LLCs changes to Tier 1 and Tier 2 of the Final Safety Analysis Report (FSAR), and NuScales Replacement Response to Request for Additional Information No. 9182 - both pertaining to NuScale Design Certification Application, Chapter 2.3, "Meteorology."
Times Topics 1:00 - 1:10 p.m.
Introductions and Identification of topics 1:10 - 1:45 p.m.
FSAR Tier 1 and Tier 2 Changes Discussions 1:45 - 2:00 p.m.
Questions from the public 2:00 p.m.
Adjourn
U.S. NUCLEAR REGULATORY COMMISSION CATEGORY 1 PUBLIC TELECONFERENCE WITH NUSCALE POWER, LLC TO DISCUSS STAFF FEEDBACK ON FINAL SAFETY ANALYSIS REPORT TIER 1 AND TIER 2 CHANGES PERTAINING TO METEOROLOGY LIST OF ATTENDEES June 26, 2018 Name Organization Brad Harvey U.S. Nuclear Regulatory Commission (NRC)
Michael Mazaika NRC Jason White NRC Prosanta Chowdhury NRC Russell Goff NuScale Power, LLC (NuScale)
Marty Bryan NuScale Nolan Bartlow NuScale Andre LEplattenier NuScale Scott Harris NuScale Mark Shaver NuScale Sarah Fields Public
U.S. NUCLEAR REGULATORY COMMISSION
SUMMARY
OF THE CATEGORY 1 PUBLIC TELECONFERENCE WITH NUSCALE POWER, LLC TO DISCUSS STAFF FEEDBACK ON FINAL SAFETY ANALYSIS REPORT TIER 1 AND TIER 2 CHANGES PERTAINING TO METEOROLOGY On June 26, 2018, the U.S. Nuclear Regulatory Commission (NRC) staff held a Category 1 public teleconference meeting with NuScale Power, LLC (NuScale) to discuss the NRC staffs feedback on, NuScale Power, LLC Submittal of Changes to Tier 1 and Tier 2 of the NuScale Final Safety Analysis Report, submitted on May 25, 2018 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML18149A404) and NuScale Power, LLC -
Replacement Response to NRC Request for Additional Information No. 276 (eRAI No. 9182) on the NuScale Design Certification Application, submitted on May 29, 2018 (ADAMS Accession No. ML18149A342). The above cited information is related to NuScale Design Certification Application (DCA), Chapter 2.3, "Meteorology." Attendees for this meeting are listed in. Ms. Sarah Fields, a member of the public joined the meeting and had no comments.
During the meeting, the NRC staff provided feedback to the NuScale staff on Meteorology related changes incorporated in Tier 1 and Tier 2 of the NuScale Final Safety Analysis Report (FSAR), submitted on May 25, 2018, including those changes that are based on the response to Request for Additional Information (RAI) No. 9186 (ADAMS Accession No. ML18044A695).
The NRC staff conducted the feedback discussion utilizing a document shared with NuScale titled, Feedback on NuScale Response to RAI 9186 and Changes to FSAR Tier 1 and Tier 2 (ADAMS Accession No. ML18177A047) focusing on clarification and correction of terminology related to postulated design temperature site parameter values.
In addition, the NRC staff discussed an apparent discrepancy in NuScales replacement response to RAI 9182. In particular, parts 1.c and 3.a of the replacement response refer to information contained in FSAR Table 11.3-12, Assumptions for Routine Airborne Effluent Release Point Characteristics for Offsite Receptors. However, the revised FSAR Section 11.3.3, Radioactive Effluent Releases, and Table 11.3-12, which were attached to the same replacement response, indicate that FSAR Table 11.3-12 is no longer being used.
The NuScale staff stated that they understood the feedback comments and the discrepancy regarding citing of FSAR Table 11.3-12, and would internally discuss the feedback comments and inform the NRC staff of a path forward. The NRC staff emphasized that one of the purposes of a feedback public meeting is to avoid another round of time consuming RAIs, and expeditiously resolve the identified comments and finalize the safety evaluation report (SER) with open items, a Phase 2 review deliverable, within the project milestone. NuScale expressed that they would most likely submit changes they believe are necessary following the NRC staffs feedback via a unilateral letter.