From:
Kotzalas, Margie To:
Johnson, Robert; Diaz Maldonado, Marilyn Cc:
Naquin, Tyrone; Brockington, Tamyra; Tripp, Christopher; Ramirez, Annie; Kotzalas, Margie
Subject:
Thursday, May 24, 2018 6:07:16 PM See responses in red below
From: Johnson, Robert Sent: Thursday, May 17, 2018 12:02 PM To: Kotzalas, Margie <Margie.Kotzalas@nrc.gov>
Cc: Naquin, Tyrone <Tyrone.Naquin@nrc.gov>; Brockington, Tamyra
<Tamyra.Brockington@nrc.gov>
Subject:
- Margie,
Please review the work request provided below, for the GNF-A amendment to Chapter 5, and let us know if you can support the review and proposed dates. This is the WR we discussed earlier this week in the standup meeting and most of the review is criticality; however, there may be elements of ISA.
- Thanks,
Robert
From: Naquin, Tyrone Sent: Thursday, May 17, 2018 11:43 AM To: Johnson, Robert <Robert.Johnson@nrc.gov>
Cc: Brockington, Tamyra <Tamyra.Brockington@nrc.gov>
Subject:
Please forward to Margie for input. Request that I get feedback by COB tomorrow. Thanks
The Fuel Manufacturing Branch of the Division of Fuel Cycle Safety, Safeguards and Environmental Review requests technical assistance for the following project:
PROJECT: Global Nuclear Fuels - Americas (GNF-A)
DOCKET NO: 70-1113
LICENSE NO: SNM-1097
ADAMS NO: ML18131A063 (Pkg)
REQUESTED ACTION: Review the License Amendment Request (LAR) for Chapter 5 revisions. Other chapter revisions will be reviewed by the Project Manager (PM). The purpose of the review is to determine, with reasonable assurance, whether the licensees requested changes will provide adequate protection against criticality hazards related to the storage, handling, and processing of licensed materials, as required by Title 10 Energy, of the Code of Federal Regulations (10 CFR) Part 70, Domestic Licensing of Special Nuclear Material.
- Determine if there are major deficiencies that make the submittal unacceptable for detailed review and prepare a recommendation to accept or deny (if required).
Provide an estimate of the hours required to complete the review, including the hours to complete the acceptance review. This estimate should be provided to the PM along with the acceptance review, which will be transmitted to the licensee.
- Prepare requests for additional information, if needed. Evaluate any additional information submitted.
- Participate in meetings, conference calls, and site visits, if necessary.
- Provide input for a Safety Evaluation Report (SER). The review should be consistent with the guidance of Standard Review Plan for Fuel Cycle Facilities License Applications, NUREG-1520.
Acceptance review requested by: May 31, 2018
RAI requested by: June 30, 2018
SER input requested by: July 31, 2018 (if no RAIs)
August 30, 2018 (if RAIs)
NMSS/DFCSE/PORSB Branch Chief please and fill in the following:
Technical Reviewer (identify lead): _____Chris Tripp (Ch 5) 80 hours9.259259e-4 days <br />0.0222 hours <br />1.322751e-4 weeks <br />3.044e-5 months <br /> estimate, Annie Ramirez (Ch
- 11) 5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> estimate_________________
Acceptance review target date: ____Completed May 24_____________________
RAI input target date: _______July 15__________________
SER input target date: _______October 15_____________________
Contacts: PM: Ty Naquin (301) 415-7352 LA: Tamyra Brockington (301) 415-8714
T. D. Naquin, CHP NMSS/DFCSE/FMB (301) 415-7352