  • =**:*.. NU SCALE

-~.

-~- POWER' May 23, 2018 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk One White Flint North 11555 Rockville Pike Rockville, MD 20852-2738 LO-0518-60081 Docket No.52-048

SUBJECT:

NuScale Power, LLC Submittal of Changes to of the Design Certification Application, Part 3, Applicant's Environmental Report-Standard Design Certification

REFERENCE:

Letter from NuScale Power, LLC to U.S. Nuclear Regulatory Commission, "NuScale Power, LLC Submittal of the NuScale Standard Plant Design Certification Application, Revision 1", dated March 15, 2018 (ML18086A090)

During review of the NuScale Power, LLC (NuScale) Part 3, Applicant's Environmental Report-Standard Design Certification of the referenced Design Certification Application (DCA) and associated engineering documents, NuScale identified an item that required correction. This correction has been evaluated to have no significant impact. The enclosure to this letter provides a mark-up of the page that corrects Part 3 of the DCA, in redline/strikeout format. NuScale will include this change as a part of a future revision to the NuScale DCA.

This letter makes no regulatory commitments or revisions to any existing regulatory commitments.

Please contact Steve Mirsky at 240-833-3001 or at smirsky@nuscalepower.com if you have any questions.

Sincerely,

~~

/4ka;;w. Rad Director, Regulatory Affairs NuScale Power, LLC Distribution: Samuel Lee, NRC, OWFN-8G9A Gregory Cranston, NRC, OWFN-8G9A Rani Franovich, NRC, OWFN-8G9A Mallecia Sutton, NRC, OWFN-8G9A

Enclosure:

"Changes to of the Design Certification Application, Part 3, Applicant's Environmental Report - Standard Design Certification" NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvallis, Oregon 97330 Office 541.360-0500 Fax 541.207.3928 www.nuscalepower.com

LO-0518-60081 NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvallis, Oregon 97330 Office 541.360-0500 Fax 541.207.3928 www.nuscalepower.com

Enclosure:

Changes to of the Design Certification Application, Part 3, Applicants Environmental Report - Standard Design Certification

Applicants Environmental Report -

Standard Design Certification Off-site Consequence Calculation Part 3 B-10 Draft Revision 2 CP-0615, CP2-1081 Table B-5: Best Estimate Core Inventory NuScale Best Estimate Core Inventory (Bq)

Kr-85 2.52E+15 I-135 3.13E+17 Ce-144 2.18E+17 Kr-85m 4.54E+16 Te-127 1.40E+16 Np-239 2.95E+18 Kr-87 9.04E+16 Te-127m 2.22E+15 Pu-238 4.99E+14 Kr-88 1.19E+17 Te-129 4.07E+16 Pu-239 9.76E+13 Xe-133 3.31E+17 Te-129m 7.01E+15 Pu-240 1.08E+14 Xe-135 1.41E+17 Te-131m 2.89E+16 Pu-241 2.75E+16 Xe-135m 6.93E+16 Te-132 2.27E+17 Zr-95 2.79E+17 Cs-134 2.40E+16 Te-131 1.37E+17 Zr-97 2.76E+17 Cs-136 7.77E+15 Rh-105 1.47E+17 Am-241 4.52E+13 Cs-137 2.52E+16 Ru-103 2.35E+17 Cm-242 8.29E+15 Rb-86 2.07E+14 Ru-105 1.53E+17 Cm-244 3.14E+14 Rb-88 1.21E+17 Ru-106 8.05E+16 La-140 2.92E+17 Ba-139 2.95E+17 Rh-103m 2.33E+17 La-141 2.69E+17 Ba-140 2.85E+17 Rh-106 8.60E+16 La-142 2.60E+17 Sr-89 1.66E+17 Nb-95 2.80E+17 Nd-147 2.86E+151.07E+1 7

Sr-90 1.94E+16 Co-58 5.07E+12 Pr-143 1.07E+172.49E+1 7

Sr-91 2.08E+17 Co-60 2.33E+13 Y-90 1.98E+16 Sr-92 2.22E+17 Mo-99 3.00E+17 Y-91 2.12E+17 Ba-137m 2.39E+16 Tc-99m 2.64E+17 Y-92 2.24E+17 I-131 1.58E+17 Nb-97 2.77E+17 Y-93 2.50E+17 I-132 2.31E+17 Nb-97m 2.62E+17 Y-91m 1.22E+17 I-133 3.30E+17 Ce-141 2.70E+17 Pr-144 2.19E+17 I-134 3.72E+17 Ce-143 2.55E+17 Pr-144m 2.58E+15