June 5, 2018 MEMORANDUM TO:
Jennifer Dixon-Herrity, Chief Licensing Branch 4 Division of Licensing, Siting, and Environmental Analysis Office of New Reactors FROM:
Jordan Hoellman, Project Manager /RA/
Licensing Branch 4 Division of Licensing, Siting, and Environmental Analysis Office of New Reactors
SUBJECT:
SUMMARY
OF A PUBLIC MEETING WITH SOUTHERN NUCLEAR OPERATING COMPANY ON MAY 10, 2018 The U.S. Nuclear Regulatory Commission (NRC) staff held a Category 1 public meeting with Southern Nuclear Operating Company (SNC) on May 10, 2018. The purpose of the meeting was to discuss issues associated with the safety review of licensing actions for SNCs Vogtle Electric Generating Plant (VEGP) Units 3 and 4.
The meeting notice can be found in the Agencywide Documents Access and Management System (ADAMS) under Accession No. ML18110A125. The meeting notice is also posted on the NRC public website. Enclosures 1 and 2 are the meeting agenda and attendance list for the meeting, respectively. The other documents referenced during the discussion can be found at the ADAMS Accession Nos. given below:
SNC Responses to Inspections, Tests, Analyses, and Acceptance Criteria (ITAAC) Closure Notification (ICN) - ML18128A368 and Uncompleted ITAAC Notification (UIN) Comment Status Sheet RAI for ALT-07, Application of VT-1 Visual Examination Methodology for Preservice Inspection
- ML18094B066 of the Reactor Vessel Nozzle Inner Radius Sections Request for Additional Information (RAI) Responses for License Amendment Request (LAR)18-003, Change to Battery Charger Output Amp Value in
- ML18115A309 Technical Specification SR 3.8.1.2 and the Surveillance Frequency for SR 3.8.7.6 (LAR-18-003S1)
CONTACT:
Jordan Hoellman, NRO/DLSE (301) 415-5481
J. Dixon-Herrity Summary of Meeting:
On May 10, 2018, staff from the NRC conducted a public meeting with representatives from SNC to discuss issues associated with the safety review of licensing actions for SNCs VEGP Units 3 and 4. Specifically, the meeting discussed (1) SNCs responses to the ICN and UIN comment status sheet, (2) SNCs planned RAI response for ALT-07, and (3) SNCs RAI response for LAR 18-003.
The first topic discussed was SNCs responses to the ICN and UIN comment status sheet. The staff discussed that they understood SNCs responses and noted that it would be acceptable for SNC to address the concerns in the ICN submittals for these ITAAC.
The second topic discussed was SNCs planned RAI response for ALT-07. SNC described that they are updating the cumulative fatigue usage factor (CUF) analysis to address the staffs RAI and that the analysis would take approximately 6 weeks to complete. SNC noted that the updated analysis would not have an impact on the supplemental information previously provided for this alternative request. The staff noted that they understood SNCs plan for the RAI response and requested a meeting prior to the final RAI response, where the proprietary details of the analysis could be discussed. SNC agreed to this request. The staff expressed a need for a full characterization of SNCs fatigue analyses, including the tools they used to perform the analyses, how the analyses were performed, the location of where the analyses were performed, how the analyses that have been performed differ, and the fatigue analyses results.
SNC stated that they understood the staffs comment.
The third topic discussed was SNCs RAI response regarding LAR 18-003. The staff noted that, after reviewing the RAI response, it is unclear whether SNC will perform a modified performance test (MPT) or not. SNC stated that their plan is to perform a MPT in lieu of performing a performance test at 48 months. The staff noted that SNCs Technical Specifications (TS) should align with their testing plan for the batteries. SNC noted that they would review the RAI response and discuss internally whether any changes to the TS are necessary.
At the end of each topic discussed, there was an opportunity for the public to provide comments and ask questions. There were no comments or questions from members of the public.
Docket Nos.: 052-025 052-026
Enclosure:
As stated cc w/encls: See next page
- via e-mail NRC-001 OFFICE PM: DLSE/LB4 LA: DLSE/LB4 BC: DLSE/LB4 PM: DLSE/LB4 NAME JHoellman (c)
RButler (c)
JDixon-Herrity (c)
JHoellman (s)
DATE 6/5/18 5/31/18 6/5/18 6/5/18
AGENDA FOR PUBLIC MEETING U.S. NUCLEAR REGULATORY COMMISSION (NRC)
Thursday, May 10, 2018 9:00 a.m. - 10:15 a.m.
PURPOSE:
To discuss issues associated with the safety review of licensing actions for Southern Nuclear Operating Companys (SNC) Vogtle Electric Generating Plant (VEGP) Units 3 and 4.
OPEN Time Topic Led By 9:00 a.m.
Opening Remarks NRC 9:05 a.m.
Discussion of SNC Responses to Inspections, Tests, Analyses, and Acceptance Criteria (ITAAC)
Completion Notification (ICN) and Uncompleted ITAAC Notification (UIN)
Comment Status Sheet NRC/SNC 9:10 a.m.
Opportunity for Public Comment PUBLIC/NRC 9:10 a.m.
Discussion of planned Request for Additional Information (RAI) Response regarding ALT-07 NRC/SNC 9:30 a.m.
Opportunity for Public Comment PUBLIC/NRC 9:30 a.m.
Discussion of Response RAI to for License Amendment Request (LAR)18-003 NRC/SNC 10:15 a.m.
Opportunity for Public Comment PUBLIC/NRC 10:15 a.m.
Adjourn
PUBLIC MEETING U.S. NUCLEAR REGULATORY COMMISSION Thursday, May 10, 2018 9:00 a.m. - 10:15 a.m.
List of Attendees Name Organization Representing the Nuclear Regulatory Commission Jordan Hoellman NRO/DLSE/LB4 Jennifer Dixon-Herrity NRO/DLSE/LB4 Peter Hearn NRO/DLSE/LB4 Frank Akstulewicz
- NRO/DEI Matt Mitchell NRO/DEI/MCB Leslie Terry NRO/DEI/MCB John Honcharik
- NRO/DEI/MCB Jim Gaslevic NRO/DCIP/HOIB Lauren Kent NRO/DCIP/HOIB Surinder Arora NRO/DCIP/HOIB Sheila Ray NRR/DE/EENB Nadim Khan NRR/DE/EENB Tania Martinez Navedo NRR/DE/EENB Representing Industry Amanda Pugh
- Southern Nuclear Operating Company (SNC)
Tom Hicks
- SNC Amy Aughtman
- SNC Wes Sparkman
- SNC Neil Haggerty
- SNC Ryan Henderson
- SNC Duane Brock
- SNC Corey Thomas
- SNC Kevin Durwachter
- SNC Calvin Marrow
- SNC Tom Petrak
- SNC Mike Yox
- SNC Kara Stacy
- SNC Shayan Sinha
- Westinghouse Electric Company (Westinghouse)
Zach Harper
- Westinghouse Representing Public Steve Franzone
Bill Jacobs
- GA Public Service Commission
- = participated via teleconference
Vogtle Units 3 & 4 Mailing List (Revised 03/13/2018) cc:
Office of the Attorney General Resident Inspector 40 Capitol Square, SW Vogtle Plant Units 3 & 4 Atlanta, GA 30334 8805 River Road Waynesboro, GA 30830 Resident Manager Oglethorpe Power Corporation Mr. Barty Simonton Alvin W. Vogtle Nuclear Plant Team Leader 7821 River Road Environmental Radiation Program Waynesboro, GA 30830 Air Protection Branch Environmental Protection Division Southern Nuclear Operating Company 4244 International Parkway, Suite 120 Document Control Coordinator Atlanta, GA 30354-3906 42 Inverness Center Parkway, Bin 237 Birmingham, AL 35242 George B. Taylor, Jr.
2100 East Exchange Pl Anne F. Appleby Atlanta, GA 30084-5336 Olgethorpe Power Corporation 2100 East Exchange Place Brian H. Whitley Tucker, GA 30084 Regulatory Affairs Director Southern Nuclear Operating Company County Commissioner 42 Inverness Center Parkway, BIN B237 Office of the County Commissioner Birmingham, AL 35242 Burke County Commission Waynesboro, GA 30830 Mr. Michael Yox Site Regulatory Affairs Director Mr. Wayne Guilfoyle Vogtle Units 3 & 4 Commissioner District 8 7825 River Road, Bin 63031 Augusta-Richmond County Commission Waynesboro, GA 30830 4940 Windsor Spring Rd Hephzibah, GA 30815 Gwendolyn Jackson Burke County Library 130 Highway 24 South Waynesboro, GA 30830 Mr. Reece McAlister Executive Secretary Georgia Public Service Commission Atlanta, GA 30334 Page 1 of 3
Vogtle Units 3 & 4 Mailing List Email acchambe@southernco.com (Amy Chamberlian) agaughtm@southernco.com (Amy Aughtman)
ALPUGH@southernco.com (Amanda Pugh) awc@nei.org (Anne W. Cottingham) becky@georgiawand.org (Becky Rafter) bhwhitley@southernco.com (Brian Whitley)
Bill.Jacobs@gdsassociates.com (Bill Jacobs) bjadams@southernco.com (Brad Adams) bwwaites@southernco.com (Brandon Waites) castelca@westinghouse.com (Curtis Castell) comerj@westinghouse.com (James Comer) crpierce@southernco.com (C.R. Pierce) dahjones@southernco.com (David Jones) david.hinds@ge.com (David Hinds) david.lewis@pillsburylaw.com (David Lewis) dgbost@southernco.com (Danny Bost) dlfulton@southernco.com (Dale Fulton) drculver@southernco.com (Randy Culver) durhamdc@westinghouse.com (David Durham) ed.burns@earthlink.net (Ed Burns) edavis@pegasusgroup.us (Ed David) erg-xl@cox.net (Eddie R. Grant) fdhundle@southernco.com (Forrest Hundley) fhwillis@southernco.com (Fred Willis)
G2NDRMDC@southernco.com (SNC Document Control) graysw@westinghouse.com (Scott W. Gray) jadwilli@southernco.com (J.D. Williams) james1.beard@ge.com (James Beard) jannina.blanco@pillsburylaw.com (Jannina Blanco) jantol1dj@westinghouse.com (David Jantosik) jenmorri@southernco.com (Jennifer Buettner)
JHaswell@southernco.com (Jeremiah Haswell) jim@ncwarn.org (Jim Warren)
John.Bozga@nrc.gov (John Bozga)
Joseph_Hegner@dom.com (Joseph Hegner) jpredd@southernco.com (Jason R. Redd) jranalli@meagpower.org (Jerry Ranalli) karen.patterson@ttnus.com (Karen Patterson) karlg@att.net (Karl Gross) kmstacy@southernco.com (Kara Stacy)
KSutton@morganlewis.com (Kathryn M. Sutton)
Page 2 of 3
Vogtle Units 3 & 4 Mailing List kwaugh@impact-net.org (Kenneth O. Waugh) lchandler@morganlewis.com (Lawrence J. Chandler)
Marc.Pickering@hq.doe.gov (Marc Pickering) markus.popa@hq.doe.gov (Markus Popa) mdmeier@southernco.com (Mike Meier) media@nei.org (Scott Peterson)
Melissa.Smith@Hq.Doe.Gov (Melissa Smith)
Michael.Kuca@hq.doe.gov (Michael Kuca) mike.price@opc.com (M.W. Price)
MKWASHIN@southernco.com (MKWashington) mlgraves@southernco.com (Michelle Graves)
MSF@nei.org (Marvin Fertel) myox@southernco.com (Mike Yox) nirsnet@nirs.org (Michael Mariotte)
Nuclaw@mindspring.com (Robert Temple) patriciaL.campbell@ge.com (Patricia L. Campbell)
Paul@beyondnuclear.org (Paul Gunter) pbessette@morganlewis.com (Paul Bessette) r.joshi15@comcast.net (Ravi Joshi)
RJB@NEI.org (Russell Bell)
Ronald.Jones@scana.com (Ronald Jones) rwink@ameren.com (Roger Wink) sabinski@suddenlink.net (Steve A. Bennett) sara@cleanenergy.org (Sara Barczak) sblanton@balch.com (Stanford Blanton)
Shiva.Granmayeh@hq.doe.gov (Shiva Granmayeh) sjackson@meagpower.org (Steven Jackson) skauffman@mpr.com (Storm Kauffman) sroetger@psc.state.ga.us (Steve Roetger) stephan.moen@ge.com (Stephan Moen) stephen.burdick@morganlewis.com (Stephen Burdick) tom.miller@hq.doe.gov (Tom Miller)
TomClements329@cs.com (Tom Clements)
Vanessa.quinn@dhs.gov (Vanessa Quinn) vcsummer2n3@gmail.com (Brian McIntyre) wasparkm@southernco.com (Wesley A. Sparkman) wayne.marquino@gmail.com (Wayne Marquino) weave1dw@westinghouse.com (Doug Weaver) x2gabeck@southernco.com (Gary Becker) x2kmseib@southernco.com (Kristin Seibert)
Page 3 of 3