LER 81-009/03L-0:on 810105,PT-27A Revealed Loss of Heat Tracing for Panel 11 Circuit 4C.Caused by Short in Heat Tape.Defective Heat Tracing Replaced.Design Change Initiated
ML18139B053
Person / Time
Site: Surry 
Issue date: 01/30/1981
From:
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML18139B053 (2)
LER 81-004/03L-0:on 810107,reactor Trip Breaker a Failed to Open.Caused by Sporadic Failure of Under Voltage Device Due to Missing Bushing.Under Voltage Device Replaced
ML18139B052
Person / Time
Site: Surry 
Issue date: 01/30/1981
From: Joshua Wilson
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML18139B052 (2)
LER 81-003/03L-0:on 810106,liquid Radwaste Monitors RM-GW-101,102,RM-VG-103,104,RM-SW-107 & RM-LW-108 Failed Low.Caused by Failed Fuse.Fuse Replaced
ML18139B051
Person / Time
Site: Surry 
Issue date: 01/30/1981
From: Joshua Wilson
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML18139B051 (2)
LER 81-002/03L-0:on 810105,PT-27A Revealed Loss of Heat Tracing for Panel 10 Circuits 1A & 1B & Panel 11 Circuit 4A. Caused by Open Heating Elements.Defective Heat Tracing Tape Replaced
ML18139B050
Person / Time
Site: Surry 
Issue date: 01/30/1981
From: Joshua Wilson
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML18139B050 (2)
LER 81-001/03L-0:on 810102,one Boric Acid Flow Path to Core Inoperable.Caused by Personnel Inadvertently Closing Valve 2-CH-226.Flow Path Restored & Personnel Reinstructed
ML18139B049
Person / Time
Site: Surry 
Issue date: 01/30/1981
From: Joshua Wilson
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML18139B049 (2)
Forwards LERs 81-001/03L-0,81-002/03L-0,81-003/03L-0, 81-004/03L-0 & 81-009/03L-0
ML18139B047
Person / Time
Site: Surry 
Issue date: 01/30/1981
From: Joshua Wilson
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML18139B047 (1)