Forwards IE Info Notice 80-34, Boron Dilution of Reactor Coolant During Steam Generator Decontamination. No Specific Action or Response Requested
ML18139A762
Person / Time
Site: Surry, North Anna  
Issue date: 09/26/1980
From: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Ferguson J
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
References
NUDOCS 8010270497
Download: ML18139A762 (3)


Text

e e

UNITED STATES NUCLEAR REGULATORY COMMISSION REGION II In Reply Refer To:

RII:JPO 50-338 50-3 0-280 50-281 101 MARIETTA ST., N.W., SUITE 3100 ATLANTA, GEORGIA 30303 SEP 2 6 1980 Virginia Electric and Power Company ATTN: J. H. :Ferguson Executive Vice President-Power P. 0. Box 26666 Richmond, VA 23261 Gentlemen:

This Information Notice is provided as an early notification of a possibly significant matter. It is expected that recipients will review the information for possible applicability to their facilities. No specific action or response is requested at this time. If further NRC evaluations so indicate, an IE Circular or Bulletin will be issued to recommend or request specific licensee actions. If you have questions regarding this matter, please contact the Director of the appropriate NRC Regional Office.

Enclosures:

Sincerely, James P. O'Rei Director

1.

IE Information Notice No. 80-34

2.

Recently Issued IE Information Notices cc w/encl:

W.R. Cartwright, Station Manager P. G~ Perry, Senior Resident Engineer J. L. Wilson, Manager

  • ~

./

e e

UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.

20555 September 26, 1980 IE Information Notice No. 80-34:

BORON DILUTION OF REACTOR COOLANT DURING STEAM GENERATOR DECONTAMINATION Description of Circumstances:

Recently two instances of boron dilution of the reactor coolant system have occurred.

Both cases were a result of high pressure washing of the.steam generator tube sheets for decontamination to reduce the radiation levels-during eddy current testing and related steam generator work.

On May 29, 1980, Trojan Nuclear Plant miscalculated the excess boric acid required to offset the demineralized water used in washing the tube sheets.

This resulted in the boron concentration of the primary coolant being reduced to less than the minimum required by the Technical Specifications.

The dilu-tion was, however, expected since the wash water was allowed to enter the reactor vessel through the nozzles.

On July 5, 1980, San Onofre Unit 1 inadvertently diluted the reactor coolant boron concentration when the high pressure demineralized flushing water leaked by a dislodged nozzle seal.

The inflatable seals had been installed to prevent the non-borated water from entering the reactor.

The resulting boron concentra-tion was greater than required for shutdown margin, but the positive reactivity added was in excess of that allowed by the Technical Specifications.

This Information Notice is provided to identify potential problem areas involved with decontaminating specific areas of steam generators. It is expected that recipents will review the potential hazards involved and consider increased monitoring of 1) inflatable seal performance, 2) vessel level, and 3) boron concentration.

Increasing the boron concentration of the primary system prior to performing any decontamination activities or using borated water for washing should also be considered.

It is expected that recipients will review this information for possible applicability to their facilities.

No specific action or response is requested at this time.

If you have any questions regarding this matter, please contact the Director of the appropriate Regional Office.

. -------~----*-----,,,_-

--*;*-*., -. --*- *--~--.... *-~-.,.-----'.""'--,...,,...,-,...,...-,-7-~*~,... ~----- <. r

,.. "T.. *

~

Information Notice No. 80-34 80-33 80-32 80-31 80-30 80-29 Supplement to 80-06 80-28 80-27 80-26

e.

RECENTLY ISSUED IE INFORMATION NOTICES Date of Subject Issue Boron Dilution of Reactor 9/26/80 Coolant During Steam Generator Decontamination Determination of Teletherapy 9/15/80 Timer Accuracy Clarification of certain 8/12/80 requirements for Exclu-sive-use shipments of radioactive materials Maloperation of Gould-8/27/80 Brown Boveri Type 480 volt type K-600S and K-DON 600S circuit breakers Potential for unaccept-able interaction between the control rod drive scram function and non-essential control air at certain GE BWR

  • facilities Broken studs on Terry turbine steam inlet flange Notification of significant events at operating power reactor facilities Prompt reporting of required information to NRC Degradation of reactor coolant pump studs Evaluation of contractor QA programs 8/19/80 8/7/80 7/29/80 6/13/80 6/11/80 6/10/80
  • Operating Licenses or Construction Permits

~

~ -~*. ~--

- -~

IN 80-34 September 26, 1980 Issued to All pressurized water reactor facilities holding power reactor OLs All teletherapy (G3) licensees All NRC and agreement state licensees All light water reactor facilities holding OLs or CPs All boiling water reactor facilities holding power reactor OLs or CPs.

All light water reactor facilities holding power reactor OLs or CPs*

All holders of reactor and near-term 01 applicants All applicants for and holders of nuclear power reactor CPs All pressurized water reactor facilities holding power reactor OLs or CPs All Part 50 licensees