ML18139A034

From kanterella
Jump to navigation Jump to search
Forwards Annual Environ Monitoring Repts,Inclucing Annual Exposure Rept & Rept of Radioactive Effluents,Per Tech Spec Section 6,& Nonradiological Environ Monitoring Rept,Per Tech Spec Section 4
ML18139A034
Person / Time
Site: Surry  
Issue date: 02/28/1980
From: Stallings C
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
NUDOCS 8003110011
Download: ML18139A034 (115)


Text

i J

~

~.*

j j

' }

~ l j

1 -

j

      • -* -*--~*-*-*-*. - --*--~*.,..**-* - ***-- **~., - --*-** **_.._......... ~---"- - ~..:-.......,_.
. / ;.* :~.

. V:iHG:rNIA E:i.ECTR.tC AND POWER, COMPANY..

Ri:cJD10ND, VxBGJ:N.IA 23261-February 28, 1980.

Mr. J~s. P *. *O'hilly.~'Direc::tot,.. _.*

Office of Inspeetion*andEnforcement

u. s. Nuclear Regulatory** ~asion Region II
  • ;
  • i\\:,.
  • 101 Marietta* Street.:.*Suite* 3100

Dear Mr. O'R~il.ly~' {),

!\\'(?>: ;

Serial. No.*.**

  • 159

. PO/RMT:scj *.

Docket,Nos. 50-280 S0-281 LicetU:Je-Noe. DPR-32

.>>PR-37

.*, '~

Enclosed* are the:. following annual: report*s for. Surry Po~r Station. Unit 1 and 2 *for: the* calendar year 19 79.

. Title of Report

. ' Applicable. Technical Specification

.. Annual Exposure:.J:'eP~rt' : ;

Report of Radia.,ctive _Effluents*':

!lonradfological:;,'lnviron_me11tal,, Monitoring**.

Report ec:

  • Mr~* Vict~r Stello.* Director Office oflnspectionand: Enforcement C

. 1*'. :.,.

.. T'.S. 6~6.'.l.b.

T.S~

  • 6.6*.3.b *.. *...

.. T.S *. 4.13'-

Very* truly* yours~ *

  • ~ -lJ// *. 01;cei~+
  • c *.. M. Stallings *

.* Vice Preaident-_Power Supply.

and Production -Operations, :

  • -Aoo'6..

s

)lvo A,.,p:

E'Hvl/.* SrfG. 11; Mn. AsNJr. s;t *

f. ?S. 'S2. Sb,

'tcO~(fOO I}

'Jill...*. is...

t I

'~--

~-~-*-

~*-**

  • ----~----*----

Docket# ~

l..ifl Control # f 003& 8 i)?.J t I Date~a i./.:kl_ __ rif Document:

~~GlJU.T!HtY oocm fU

e l_

INDIVIDUALS TOTAL DOSE(REM)

REACTOR OPERATIONS SURVEILLANCE 193 162.618 INSERVICE INSPECTION 20 30.737 ROUTINE MAINTENANCE 405 549.849 SPECIAL MAINTENANCE 2324 2560.998 DE1UELING 9

4.342 RAD WASTE PROCESSING, S'OLID 47 45.375 RAD WASTE PROCESSING, LIQUID 4

2.974 RAD WASTE PROCESSING, RESIN &* 1ER 1

2.580 3003 3359.473 TOTAL INDIVIDUALS INCLUDE 19 WHO HAVE BEEN COUNTED IN MORE THAN ONE JOB 1UNCTION,

\\I l H c; 1 NI A i:: L ; J: T !,.' 1-:

~,

i' 0 1-.' EH.

C n.

SUH HY i' n '.. *;: ii

~; ';',\\ *- :-, ;.:

1.lr.ENCE NO!-: :,,',,- '*2

i.
  • . _*,, i

.JAN u AR y 'i' 0 I) E C rm B L ls

(1 7 9

--**-*-----*--*-*. ----*------- ---*-. - - ----------------------------- -- *---*----------*** -- --------------*---*----~-*--------------*- *-*-**--*--*- - ---*-*--------***-----------------. --* -* -*-*--------- ---

I

'.,TATION EMPLOYEES i

liTIT,T.TY irnPLOYEES CONTRAC'i',1i, L _____ ***--------------* ------------* ____ i ____________ ------.

\\ N1-;-~~;~-;~-F---i o ta l nos e I N u m h (' r o F i T o t a l n n s ('

' N urn h e 1:

o I'

! T () I:.t jTnd:Lvidu;:ils I Rem iincliviclu:i:i.s J

.Jo r, ruNCTION

__________,_!.~) d :L V id lJ a ls.

RC rn --:------------1--------..... -*-,-. ________ ;_ ----

I l~EACTOR OPERATION & SURVEILLANCE I 193 162.618 0

I i


*~------*-----'-------

20 30.737 I

T N S r,; 1n: 1 C E 1 NS P I~ CT T ON 0

0 0

0 0

.........._.. ___________________________________, ________________ !----------'l*---------i---------------------: _______ _

_i __ _

0 0

ROTTT /'NE MAINTENANCE 142 265.086 I

I 30 27.840 233 256.923 SPECIAi. MATNTENANCE

SGRP, l'Tl'Tr.:r; MOTJT!"l(:,\\TTON, BASE P'LATE, C;'\\r-*:*irnNTCS, i'Tl'Hlr. SYSTEM ANA-Ly s T s,

s *rn AM Ci~ 0i ER AT() R T lf n E,

irni)Y_ CIIRl{lrnT, HEMOVAL & PLuc:r,JNG

i.

I i

I 18 26.882 I

I

___, _________ _J ____ __

5 3.677 i

47 44.487 2,259 i

--~-------*--+

4 0.665 0

---**-*---*--*-. - -----*--- --- **---**--*----------------------*-*-*** -.l.------*-*----*-*------*----------**------1-- --------*---*--*-*--*--- -----1----------

  • WAST!*: PROCESSING
  • 1,1.QUTT>

snr,Tn i

4 I

I *-*--

~-- ________ 3 ___ _

2.974 3.077 I

0 0

1

. _.. __________ o __________., ____________ o __ __

0

_44 2489.629 I ___ _

0 0

42.298 I

1n:STN THANSfEH i

1

e 2.580 i

O O

______ L_

0 *---------

  • -*-------------------------------------------**---*-----------1-----*.-----*---------

0 19 persons are included in more than one job function

_j

e

\\*

_.,/

)

)

  • -1 --............ -. -
'-:. *._J*_._-\\.

--~

~

)

-~

  • _.::,,~::.:.. i::J.e t:.::.. :*~1o~~ure l.-S9

-*2.c-0 *2.49

.75G -1+99 1:0- //19 i S :J--::: S 9

  • J :*.1oc.-~J_9sg

.LO C;C-~~299 9

~000-~3999

-4000=4999 5000=5999 600(}=6999 7000--7999 SOOG-C999 9000--9999 10000*-10999 ll000-~11999 12000~plus I

_**.s. -.

.) 2 :=.:: d -;- *:: >--:

i

_* ~:. !...

1.* ~ :_~-~ ~,_:,_:_?~

..:*.*.'i_:-./]*,_,y ::::,:__~

.__,*.:::s

,-:r.. _:_

.
  • .:**~_-:;

5755 2082 811 468 336

-

  • 19 9* -..

. 605

  • 314* *
  • 13 6 54 35

___ _1_8 __ _

5 1

0 o __

Tot-21 :*,ur:ber of Indi--.ri.Cu.ols :ce1-;c,rted 10,820 The above infon)ation

..*';10
n individual r.*:oni toTing is s,.i1':::i.t~c:d for,he i-c,~~,l -r>uc:-*ber of ~.-;.div:icuals
2.s _prc,,*ide.d,~ur*cng tl1e c.ale.ndar yr-.1ar.

for

FACILITY:

Surry Power Station II.

AIRIJOI\\NE RELEASES (CON'T)

8.

Isotopes Released (con I t)

(b)

Halol!ens 1-131 1-132 1-133 1-134 1-135

( C)

Gases Xe-133 Xe-133m Xe-135 Kr-85m Kr-85 Kr-87 Kr-88 Ar-41 III.

SOI.ID RADIOACTIVE WASTE DISPOSAL

1.

(a)

'fotal Ainount Solid Waste Packaged (Ii)

Estimated Total Activitv (c)

Date of Shipment and Disposition UNITS Curies f'f 3 Curies e

RBPOR'f OF RADIOAL"l'IVE EFFLUENTS DOCKET; 50-280 and 50-281

=*

JULY l.06E+4 2.0'.lE+l'

Barnwell, s.c.

7-2-79 7-7-79 7-8-79 7 79 7-13-79 7-16-79(2) 7-18-79(4) 7-19-79 7-20-79 7-23-79 7-27-79 7-28-79

'IC

'IC

1. 24E+4 4.08E+l *
Barnwell, s.c.

8-2-79 (3) 8-3-79 8-7-79,

8-10-79(2) 8-13-79 8-17-79(3) 8-20-79 8-21-79(1) ll-28-79(4)

SEPT.

'IC 6.50E+3 9.llE+o Barnwell,-

s.c.

9-2-79 9-12-79(2) 9-17-79 9-18-79 9-20-79 9-25-79(3)

PAGE 3 YEAR ; __

1_9_7_9 __ _

.... D...c**onmi 3.07E-6 4.0lE-6 7.53E-2 3.04E-2 6.64E-3 4.lJE-2 5.27E-3 l.OOE-2 l.l 7E-2

6. 73E+3 l.53E+l

-Samwell, s.c.

10-4-79 10-5-79 10-8-79 10-9-79 10-10-79(2) 10-12-79 10-19-79 10-23-79 10-26-79

  • o!icm,mr,:a

_NQVEMIJEJL **- ---

1.13E-4

--ir.51lr-4 2.17E-S LJJ~-:,

l.18E+l 3.43E+2 l.90E+o 1.56E-l

-r.T.!Et<J 2.SOE-2 l.bZE-2 2.73E-l

4. 71E-2
1. 49E-l 5.lOE-2 3.29E-2
3. 38E-2 i'l. 2ilE-3 5.34E+3 2.47E+3 l.17E+l 2.24E+O Harnwe!!,

llarnwell, s.c.

s. c.

.LL=T /~ {2JJ.T-5=7Y 11-2-79 12-11-79 11-6-79 12-14-79 11-13-79 12-19-7~

11-14-79 11-21-79

-- TOTAL~~"~ -:r-r,:Rnoir-~

~--~~"~

9.67E-4 8.211,

  • J. :,ui,.-)

3.32E-6 3.55E+2 3.02E+l

1. 90E+o
l. 62E-l 5.SlE+O

- t,.68E-l 4.78E-2 4.06E-3 3.14E-I 2.67E-2 IUllE-1 6.81E-2

~- J~E--2

--- ---,~

5.38E-2

- - -*li: 57E-3 4.40E-t4 9.95E+l

---* ---~------~

I I l'acillty:

Surry Power Station I.

  • LIQUID RELEASES
1.

Gross Radioactivity (By)

(a)

Total Release;

{b}

Avs, Concentration Released Cc)

Maximum Concentration Released

2.

Tritium (a)

Total Released (b)

Avr.. Concentration Released

3.

Dissolved Noble Gases (a)

Total Release (b)

Avi,.. Concentration Released

4.

Gross Aleha Radioactivity (a)

Total Released

. (b)

Avr.. Concentration Released

5.

Vol. of Liquid to Disch. Canal

6.

Vol. of Dilution Water

7.

Isotopes Released NPC \\JCi/ml 1-lJl 3 X 1Q-'I I-132 8 X 10-G 1-133 1 X 10-*

l-13lt 2 X 10->

l-135 4 X 10-*

Cs-134 9 X 10- 0 Cs-136 6 X 10-0 Cs-137 2 X 10-*

Kc-85 3 X 10-b Co-57 4 x 10-*

Co-58 9 X 10-o Co-60 3 X 10- >

Hn-54 1 X 10-~

Na-2li

) X 10-*

Cr-51 2 X 10-'

Fe-59 5 X 10- 5 llb-95 1 X 10-~

Ba-La-140 2 X 10-s Rb-88

~UIHTS --

Curies

\\JCi/ml

  • \\JCi/ml Curies

\\JCi/ml Curies

!JCi/ml Curies

\\JCi/ml Liters..

Liters Curies REPORT OF RAUIOAC'1'IVE EFFLUENTS DOCKET:

50-280 and 50-281 JANUARY FEBRUARY MARCIi 7.99E-2

1. 78E-l l.83E-l 3.16E-10
1. 16E-9 l.43E-9 2.79E-10 1 r;or,:-9 3.30E-9 4.%E+l 7 'i4R+l 4.59E+l l.96E-7 4.93E-7 3.59E-7 7.OlE-l 2.58E-l
1. 30E+O
2. 77E-9 l.69E-9 l.02E-8 5.67E-6 5.23E-6 2.24E-14 4.09E-14 8.03E+7
5. 77E+7 4.65E+7 2.53E+ll l.53E+ll l.28E+ll 2.63E-2 4.91E-3
1. 69E-2 l.12E-l 1.73E-2 l.14E-2 1.ME-1 1.93E-2
6. 72E-3 9.44E-2 l.65E-2 2.13E-3 1.64E-l
1. 86E-2 9.l14E-3
1. 33E-2
4. 38E-2 4.87E-2 5.42E-6 4.54E-2

!l.!ILE-:.!

l.07E-l l.lHE+O

1. 31E-4 2.64E-4
1. 71E-6 8.82R-2 l.47E-l
1. 38E-l
8. 61,E-2 l.15E-l
6. 6.9E-2
5. 62E-3 8.29E-]

4.42E-3 2.0lE-1 2*.69E-2 8.30E-3

1. 38E-2 4.84E-2 1.16E-2
1. 61E-l1 8.32E-4 1.28E-2 9.39E-4 l.15E-5 2.lOE-5 2.75E-6 APRIL 1.098-1 1.0lE-9 2.lOE-9 2.27E+l
2. lOE-7

/

7.18E-3 6.65E-11 3.l 7E-6

2. 93E-14
3. 70E+7 1.08E+ll
4. 74E-3 L 79E-2
>.L/11-l ti.til.E-ti
3. 20E-l 1.00E-1
5. 9 SE-3
1. 52E-5 l.14E-2
l. 42E-6 1.29E-3 PAGE l YEAR:

1979 MAY JUNE l..34E-1 9.16E-.2

1. ]bE}-9 9.69E-10 l.23E-9 8.88E-10
3. 31E+l 3:.48E+l 3.36E-7 3.68E-7
6. 52El-5 ii.CilE-B J.. /UIS *t, 8.3HE-6
1. 72El-14 H.H7E-14
3. 75E+7 J.b:>E+7 9.86E+l0

!l.ti:>.li+lU 9.95E-5

3. LUE>-.!
3. 2SE-2 tl.Ltl.l>-.::

/,JbE-2 K

1.59E-4

l. 4 IE-ti 4.55E-l 3.64E-l 3.07E-l 2.90E-1

"* t, /l!,-i.J

1. 23E-3 1,.J,:;,:.,:*q 4.51E-5

-:r.o41,.-cr-l.51E-3

~. 30E-3 2°';"1bE-4 3.14El-6 10-25-78

- -* =p,

'l'OTAL

-,, l!.rror 7.76E-l 6.60E-.!

I 2.62E+2 2.22E:+1 -.-

2.27E+O l.93E_;l 2.42E-5 2.0SE-6 2.96E+8 1.03E+7 8.35E+:fi:

2.92E+l0 5.29E-2 4, SQE-*3

    • - l~:lOE-2 l.41E-l
l. JUE-1

_1.1~-:.! '

l.lJE-1 9filE-2 L!llE-1 I.

E-- -

1.0,c.-l

-1.

E- --

'.>.ti:.!E-1>

z,.61'E=,-

4.41E-l J.75E-2 1.lHE+O

f. OOE-1
1. l4E-J
9. 72E-5 l.:>lE+U
1. 29E-1

,.o5E-l 1r.2IE-2 3.02E-2 2.57E-J 2.:l6E-I L, lJ.Lr. *L l.UE-l 9-. 6IE-3 T.uZJr-r--- }. 38E-5

1. tl4E-2
1. 56E-3

], H4E-5 3.26E-6

e l'ACILITY:

Surry Power Station I.

LIQUID REI.EASES (CON'T)

7.

Isotopes Released 1Jl-lPC Ci/ml Ce-141 9 X 10-*

Ce-144 1 X 10-"

Xc-133 J X 10-*

Xe-135 3 X 10-0 Ar'-41 3 X 10-*

Sr-89 3 X 10-*

Sr-90 3 X 10-C-14 8 X 10-*

8.

Percent of 10CFR20 II.

AIRBORNE REI.EASES

1.

Total Noble Gases

2.

Total llalor,ens J.

Total Particulate Gross Radio-activity ((3y)

4.

Total Tritium

5.

-Total Particulate Gross Alpha Radioactivity

6.

Maximum Noble Gas Release Rate

7.

Percent of Applicable Limit for Technical Specifj_cations

{11)

Noble Gases (bl Halogens (c)

Pa1*ticulates 8,

Isotopes Released:

(a)

Pai:ticulates Cs-134 Cr-51

  • Cs-137 Cs-138 Co-58 Co-60 Mn-54 Fe-59 R.~-88 "urIT-rs r.,,ries Percent Curies Curies Curies Curies Curies uCi/sec Percent Percent Percent Curies e

REPORT OF RMIOACTIVE EFFLUENTS DOCKET; 50-200 and 50-281 JANUARY f.'Rl>Df!AUV MARCIi 2.58E-6 4.41E-6 2.09E-3 9.61E-6

3. 93E-2 1.48E-l 1.05E-l 6.49E-l 2.34E-2 l.19E-2
4. 74E-4 1.09E-4 2.50E-5 9.09E-5
1. 36E---4 l.99E-6 2.00E-5 l.08E--:5 3.12E-4 l.Tl'iE-3 I. li9E-:3 l.96E-l 7.64E-2 4.02E-l 6.97E+l
1. 33E+2
1. 20E+3 3.85E-5 9.69E-6 3.40E-3
5. 71E-S 2.54E-4 l.OOE-4 I. 1.111-ttJ 2.00E+l 2.oi:111-t-.L 2.99E 7.05E-7
1. 20E-6 I.27E+2 2.78E+3 l! *.io11+3
6. 72E-2 9.74E-2 8 09F.-]
  • 4.05E-4 l.18E-4 3.62E 2
l. /UE-J 2.14E-3 l.29E J 5.67E-9 2.75E-9

. 4 68E.o 5.22E-6

4. 51E-5 4.0lE-6 4.0lE-6 l.25E 5 9.0SE-3 l.20E-J
3. lliE-4 1.64E-5 8.09E-5 4.13E-5 l.26E-4 4.17E-5 6.0lE-5 l.26E-7 4.55E-7 l.2JE-6

--- -==1:~.2.~:;L = 5,_311,-4

_ !LlBE=.5 APRIL 2.lSE-6 7.18E-3

3. l18E-S 9.07E-6 9.22E-4
2. 76E-2 l.59E+l
1. 91E-3
6. 20E-5 3.84E+O J.02E-6
1. 5IE+2 l.03E-2 2.21E-2 9.46E-4
l. 48E-8
4. JlE-6
3. 58E-5 4.15E-5
  • * * =

PAGE 2 10-25-78 YEAR: ___

1_9_7_9 __ ~

=~~

~ _ JUNE _ _ -

-::-rof AT:="'~~

MAY

1. 98E-5 2.68E-5 2.lOE-3 2.99E-l I

6.84E-l--*

6.06E-5 6.34E..:~*- -,

... 2. 71E-5 2.39E-5

3. 38F.-!,

6.24E-6

-,-.TJTF:=r;- ---------.

5. 52F.--:,

~~ ~ ]~lE-5 2.87E--5

-*,; ~69E 6. 34E-t, 7.19E-4 -*

2.27E-2 2.23E-2 S.SBE-3

-r.:m,;-:5- ---if:Sqir-:r-2.lOE-4 3.BJE-5

  • :>. _jUt,.-t-U

.L.4Hll-t-U

5. 30E-6
2. 79E-6

~~-

~

3.47E-6

1. 27EJ--4 9.90E-8 l.82E-3 2.24E-4
3. 37EJ--9 l.39E-6
2. 03EJ--5

-~~

6. 37E-5 -- -*--* ir.""91JE"=" b
7. BOE-5

io-----

-===<= ------=-... -

5.42E-3 t,. 60E-4 l.42El-"l

--).]7E ~:,- --

I. 21E+2 1,*.::;*!;R--=li*-

7.21E-4 G.LlE-5 6.5281*1. ---- -

'>

  • 54 E-*0 __
1. 60E-5 I.16E-6 1.42E:6-* -

S.03E-5 i-:-21E---::=r-*

'i. 2sE 1.(,"JE-6 C9BE-4--

5.42E-5 l.06E~-2

.. *1 2.47E**'*

---y?j')"jf.. T;- -T.To~

2*.--9-5g_5--

  • l.8Tu-u ____ --l. 54!,:-7 --

-~----------.~-----

c*- 2,HE--]_ a.c I_

FACILITY:

Surry Power Station RltPORT m' RADIOACTIVE EFFLUENTS DOCKET; 50-280 and 50-281 YEAR:

1979 e

PAGE 3 I tl -i'i-78 II.

AIRBORNE RELEASES (CON 1T) 8 :--'=1=s=o:=to=,n=e=s=R~e*0*1e=e=;;=s=ed-;a=(Fc=o=n""'1 =>st ),========il=s~~=li-='illllb!!!.!!!.b==J~.n.l!e!!ftKL.=,l=~~~==-ll=A~Pt..!R~I:.,iT~. *=~ ~~-"_:_:. :lj.!filL=,:-:-~-=-~r:-t:'~f'.\\~~:

t----'(-'-b-'-)---::~"'=~~

0

=--!~~~e:;.:;n:.::s __________,1-------lf--::-c,.,,.-,,-::---f--,,-...,-,,--,---,,-------ll-l-. 9.,..l-E---3--l-~l-.1~4=E-~5--__ ::18. 54E-9

5. 2;~:].,:~~,:;~~~=

UNITS

.. T AMUARY _

EKBRIIARY MARCIi Curies 3.61E-5 9.49E-6 3.23E-3 1-132 1.211*:-r,

, I.IL(E-~

n-------;:I--~13::-:3c--~---------11-----1-~::-,-:;~.;;---lf-;:.:..;=-=c...:.:.--11-"'-'--"""-"-..::,_-+-*----,11--~.---**-- * *

  • 3.921,:-~----*1, 1.J:nr=1,*-
1. 51E-6 2.llH-8 l.19E-4 M-------:1,..-7173l-=-' -----------ii-----,11-~~c....;.--ll------+-,,------li--*----1-~*--- -. *-

-Ll4-£l'= ]- --~,, :-())g:.3-

~----'('"'c~)--:-~:-:"'~~~!::'.13-,::------------il----ill--c--~---l--,-------l-------11-l-:'-91-,+-l--i~~J --~= * :

: :::::~: )\\i ;~;~-~

4.16E-7 l.81H-7 3.86E-5

4. 74E-7 7.52E-6
5. 39E+l
1. 30E+2 l.15E+3 Xe-l33m 7.80E+O

!1... (dE-l Xe-135 6.0811+1

. *1:~-17~+6=_

Kr-8Sm

7. 36E-I I/. :-TGE=-2 Kr-85 2.581,:-2_

ll'.!.19E-3

1. 19E-3 7.80E+0 l.04E+l 2.70E+o
4. 77E+l
l. l 7E-l 5.80E-2 5.61E-l 2.58E-2 Kr-87 3.0liH ____ -y:-51m= l.87E-l 6.lOE-2 5.32E-2 Kr-88
4. 56~-- :lfITT~----

2.7bE-l l.lOE-1 7.02E-2 Ar-41 2.211,:+t)

. ~1-2.lUE-tt.1 l.U2E-l l.28E-2 III.

SOLID RADIOACTIVE WASTE DISPOSAL

1.

(a)

Total Amount Solid Waste Packal!.ed (b)

Estimated Total Activitv (c)

Date of Shipment and Disposition FT 3 Curies

1. 6SE+3
b. / 11,ttJ

\\Barnwell, s.c.

1-2-79 1-12-79 1-15-79 1-22-79

( ) with dates means that number of shipments for that date.

3. 70E+3 1.51E+4

'.>.J7E+o ll.lUE+l

Barnwell, Barnwell, s c.

s.c.

2-1-79 3-1-79 (2.)

2-9-79*

3-6-79 (2) 2-20-79 3-7-79 2-22.., 79 3-8-79 2-27-79 3-12-79 2-28-79 3-13-79 (2) 2-28-79 3-15-79 2-28-79 3-17-79 3-19-79 3-23-79 3-2 7-79 3-28-79 (4) 3-29-79 (2) 3-30-79

9. 46E+3 9.89E+3 l.28E+4 5.26E+4 4.57E+I 9.U4E+l l.59E+l 2.45E+2
Barnwell,

~arnwe1.1-,

narnwel.l.,

1-*

s.c.

s.c.

s. C.

4-2-]if 5=-:;=79-o-I=7!f -

4-6-79 (4) 5-9-79 6-7-79 (4) 4.;J8-79 5-11-79(3) 6-8-79 4:-9-79 5-15-79 6-13-79 4-11-79 5-16-79(2) 6-H-79 4-12-79 (2) 5-18-79 6-15-79(3) 4-14-79 5-19-79 6-16-79(2) 4-17-79 5-21-79 6-17-79 4-20-79 5-22-79 6-22-79 4-21-79 5-23-79(2) 6-24-79 4-22-79 5-24-79 6-25-79 4 79 5-25-79(2) 6-26-79-(2) 4-26-79 5-29-79 6-27-79 5-30-79 (2) 5-31-79

I I

I Facility:

Surry Power Station I.

Lil)UIIJ RELEASES

1.

Gross Radioactivity (fly)

(a2*

Total Releas<!

(b)

Avv.. Concentration Released (c)

Maxlmum Concentration Released

2.

Tritium (a)

Total Released M

Avg. Concentration Released

3.

Dissolved Noble Gases (a)

Total Release (b)

Avg. Concentration Released

4.

Gross Alpha Radioactivitv (a)

Total Released (b)

Avg. Concentration Released

5.

Vol. of Liquid to Disch. Canal

6.

Vol. of DJlution Water

7.

Isotoees Released MPC ~Ci/ml 1-131 3 X 10-7 1-132 8 X 10-6 1-133 1 X 10-*

l-13li 2 X 10-*

1-135 4 X 10-*

Cs-134 9 X 10-*

Cs-136 6 X 10- 0 Cs-137 2 X 10-*

Kr-85 3 X 10-*

CQ-57 4 X 10-*

Co-58 9 X 10-s Co-60 3 X 10-*

Hn-54 1 X 10-~

Na-24 3 X 10-s Cr-51 2 X 10-3 Fe-59 5 X lO-*

Nb-95 1 X lQ-4 Ba!..J,a-140 2 X 10-5 Rb-88

-.UNITS Curies

µCi/ml

\\!Ci/ml Curies J1Ci/01l Curies 11Ci/01l Curies JJCi/ml Liters Liters Curies e

REPORT OF llAl}I0ACTIVE EFFLUENTS DOCKET:

50-280 and 50-281 PAGE 1 YEAR: 1979

=

==-=~-=-==-==-~=-==-~-====..:"-~*-*--* *-***-*--.:-_..=:.......'L7s.----

.........- r=+-"'-"==::z:::::s:

SEP;;; -

=OCTOBER-

~NOW.M~filL -DECEMIIBlr~

TOTAL --* + ERROR JULY

__AUGUS'.L..__

9.54E-2 1, """* :,

2.46E-l 5.13E-l

1. 76E+O ---
2. 31,E-l 1.46E-9 5.97E-9 4.13E-9 3.62E-9 4.31E-9
  • --- ----=-+-

l.83E-9

1. 76E-9 l.55E-6 3.60E-7 3.04E-9 9.7SE-7 3.15E-9 l.07E+l 1.59E+l l.81E+l 1.24E+l 8.18E+O 3.0JE+l 9.56E+f-* -

-8. lJE*t-0

- 1.65E-7 2.37E-7

2. 77E-7
1. 82E-7
6. 39E-8 2.57iIH

.\\

T I

5.48E-4

l. t2E-2 l.07E-l J.7.Z'SE=r ____ r. mm-2 8.0oE-1:.!
1. J4E-lU tl.99E-l~

7.75E-6 5:o4E-6 4.UuE-=o-2~

.,_~-.,- 1.66E-6 l.19E-13 7.53E-14 5.ooc.-14 Z.U~l>-.l4

\\

3.7JE+7

3. 73E+T 3.68E+7 3.95E+7 4.47E+7

.J.:iuE'FT-- -'27:!I1ll8

  • s-:-IT9ll+~

6.52E+l0

6. 70E+l0 6.54E+10
6. 80E+l0. '

1.28E+ll l.19E+ll 5.13E+ll l.80E+l0 i

l.85E-4 l.07E-2

. l.09E-2 9.27E-4 I

l.OOE-4 l.Y:IE-3

.l.bJE-=3-- -r. 39E-I, 2.62E-3 2.62E_:-3*

2.23B-4 w

T 2.13E-2

7. 81E-2 Z.llbll-:l 2.54E-:.i 5.12E-2

].blE-2

2. 4 n,:::r-** 2~ff5E-2.

.1.u1m--:l

~.:i:iE-2 8.44E-2 5.l,OE-1

/i.59E-2 2.75E-4

1. 81E-4 8.68E-5 7.93E-5 T.1171Hi 3'.o5E-5
8. 70E-4 7.40E-5 8.64E-2
8. 76E-2 4.lfJE-2 2.84E-2 2.SlE-2 I.1i9E-2 2.87E-l
  • L44E-2 I.?i7E-1 l.35E-1 9.06E-2 T.ZlE-1 l.llE-1
8. 21E-2 6.87E-1 5.84E-2 3.09E-3 2.SOE-3 2.3/:E-4 TI2E-J 1.86E-3 *- 9.0lE-4 -- ~DJim=-r-- *8. 50E-4

-ii l.loE-3

1. 75E-3 T.gTE-3 2.47E-4 8.41.L-,. -

-r.TT~ l.27E-5

~.J./1,-)

9.73E-4 tl.:i:it=-2--** 7:-27E-3 1.88E-4 l.85E-5

2. 22E-/1
  • - TI9E-4 ___ 7.05E-5 3.96E-4 4.56E-6 3.88E,-5 16.49E-6
9. 77E-S z.:.illE-4

- -13.b31H 3.09E-5 I*

~..------

  • REPOlt'l' OF RA.J>IOAC'l'IVE EFFLUENTS, DOCKET: 50-280 and 50-281 l'AGE 2 JIAClLl'l'Y:

Surry Power Station YEA!! : __

1_9_7_9

e:E::::::e:C::::) Ci/ml r.~:lil.. ~Hr~Tt~~;=at=='iT.i~=~=..======,-==--;="""'==a,;=oc=T"'O~B"'E"'R===l'l=f>~.V~!'=,H=l!=Jl-li~_"~a ~i~;::;1=::Jfu]fL~. ~- '_*Jj[iM:~ ~
7.

JULY

_ __AUGIIST SEPT.

1.

3.14E-6 L,.2SE-7

1. 48E-6 Ce-141 9xl0-0 5.36E-5 7.54E-5---**1

l.14E-5 Ce-144 1 x 10-"

l.02E-5 1.07E-3

  • - - 7.4/E-6

-r:T!"E-1 _____ -,r:-s:iE-5

-*--:;X-e--:l;--;3;-;:3~---::3-x-"--:lc-:Oc::::,;-*--------f----i----..-----f---"--'-"-'=--'<---J--,------1-.,,...,3.6,....7"'E~-.;,.5---lh01-'-.3""'6;..;E;...--2~---.. 9.98E-2 1.lJE-1

  • ,;:-6-IE-,- Xe-135 3 x 10-*

4.82E-4 3.58E-3 _____

--~7-~.3~3=E--"""3--K-1~.-l-4-E---' **9-~

5.58E-b 2.92E-5

---A-r--~4-l ___ )_x_l_0_-.* --------41----~------*------"------"---;v--

- -~r--

4. 27E-5

;:S:-r--n8~9----=-J-x--clc-:Oo:_:-.

.* :---------f-----t----,,--,-=-=---l---:--=-=---+------i-----'--I--------

9.47E-5 l.61E-4 5.51E-4 2.26E-5 J.84E-5 3.21E-4 l.62E-t,

2. 76E-4 7.65E-5 Sr-90 3 x 10-

:C:-_-:-174----::-8-x--cl:-:Oc--_ *.,,---------11----ll----,,--,=......,.--11---=..c..;;.-=....:c.--1---.=..;="-'~-1------I------*-*------*------* *----

l.b9E-2 3.46E-2

1. 77E-2 1_8::..:.... __

.=.P.:::e=-rc:::e::.:n"-'t:....,:o:.:fc...::l.:::OC:::F:...:* R~2"-'0'-----------jlJPE.!ei.l*ra.!*"..seUUa" ~4-_;;::.:_:..:.;~:.....--1-::.:..::=.::....=:........_l-..:!:..:..:..:.!!:...:__j....:l::.*:..:5:.:1::E:.-..:2:...__ll...:l:..:...:6..:6::E-=2~~~~ '--* 0_7_E_-_2_~,------ -----

ft*I""l'--'.'---'A~l"-'R""B-"O"'R'"'NE:c.*...:Ro::E:::cL:::E~AS"-'E:;.:S:........ _______ --ll------l------a------1-------1l------1*----'---*H------11---~--~i------

C11des 2.17E-l l.21E+l

.). 51E+2

1.

Total Noble Gases 3.63E-~2 3.0%+1 c"~'es 7.Ol!E-6

-r.:I5ir-:r.-. ~-041'-4

2.

Total Halogens

..,.......,..,...,....-r---~l--.=o~lE~' -lJ--:-S'lE-5

-;;J~.--~T;'o'-=t:..;;a~l'--P;:a:cr=.:t~i~c:..:.u~l:...a.,-t-e-,G""r-o-s-s--:::R-ca-;d-;-io-------f-.!a<!I.LLJ~-1t--------1i-------ll------l......:..:..::.::.=....=. __ l....:..::....:....:-=..._:_ __ tt---=..:~-=--.:_--1--=.:::::..::__: ___ *-----*-

4.
5.
6.
7.
8.

ac tiv itv (llY)

Total Tritium Total Particulate Gross Alpha Radloactivitv Maximum Noble Gas Release Rate Percent of Applicable Limit for Technical Specificationoi (a)

Noble Gases (b) llalonens (c)

Particulates.

Isotopes Released:

(a)

Particulates Ca-134 C:r-51

l'e-59 l\\~::-88

..£!tries l.28E-4 C,*rtes 9.65E-l c,,rJei<

6.43E-6 11ciisec -,

Percent Percent Percent l.49E-J CurJeu l.23E-5

3. 79E-5

~

6.44E-5 7.53E-7 l.19E-4 6.34E-5 4.25E-6 l.27E:m--

4.45E+o 7.93E-l 4.00E-6 J. 73E-6 7.69E-7 l.OOE-1

3. 39E-4 3.45E-5
1. 25E-3 9.00E-4 5.91E-4 8.85E-6
1. 75E-6

--r:TliE---i.--

3.07E-5 1.9-IIE-5 J..:rnc.-'.>

7. 81,E-5
1. 38E-5 7.54E-b 2.72E..:~

5.75E-5 --r.Bo'E=s-3.32E-5 5.79E-7 4.89E-5

1. 32E-4 2.B2E-4

~.98ETU 7:li9ITTO 5.67E-6

2. 68E-6 2.33E-5 I.. 98E-b

--r.9TIE+I- -*=~--.. ------*-*---. *------

  • -l.OJE+4 9.06E-3 2.32E-1
l. JlE-3 9.54E-J ll.57E-4

-:l-:-1"3E-3 7.38E-6

. -~9E-5--. 4. 83E::5--

,,.1rn-6

-z:ll9E-5 t,. 56E-5

'1~1rn-:::.4*- -D~SE -**r.-cr6E:.~

I.JiE-4 3.2rn:.:z*- -2:-n~

3.82E-6 L.OJE-'.>

7.1 SE-::-5---- 6:08E-6.

4.18E-*5 ----

2.iJIE-li 4.47E-l, *-*-- -J~BOE *

-* 7.OliE-i'i

8. 37r,::*6 ___
7. llE-7 l.62E-l, -- -r:111,~ :r:m-=z---*

2.92E-5

~-;.:.a.:.. ___

e e

Section 4.13

4. 13.A. 1 4.13.A.2 4.13.B
4. 13. B. 2
4. 13. C.

SURRY POWER STATION NON-RADIOLOGICAL ENVIRONMENTAL MONITORING REPORT Title Non-Radioligical Environmental Monitoring Program Temperature and Salinity Monitoring Continuous Water Temperature Monitoring Fish Sampling Additional Seine and Trawl Sampling Ristroph (Low-Level) Screen Monitoring Program Pages 1

2 thru 27 28 thru 32 33 thru 46 47 thru 50 51 thru 103

e e

4~13 NON-RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM The non-radiological environmental monitoring program applies to the m6hitorfng of the temperature-salinity distribution and the biological variables in the 10-mile segment of the James River Estuary centered at Hog Island.

The program is conducted in order to (1) to further characterize the relationship between the thermal discharge and the physical-chemical characteristics of the water mass within the 10-mile tidal segment of the James River; (2) to further verify the continued efficiency of the Ristroph traveling fish screens; and (3) to monitor the fish populations in the James River utilizing the data collected from the screens.

e

( 1.)

4.13.A.J TEMPERATURE AND SALINITY MONITORING 4.13.A.1.1 METHODS This program is conducted at monthly intervals using boat cruises along the scheme illustrated in Figure 4.13.A-1.

Sampling starts along the lntakes-Skiffes Creek transect just before low slack water, proceeds upstream, and concludes with the Jamestown lsland-Crou-:hes Creek transect.

At each station temperature and salinity are measured at two-meter intervals from surface to bottom.

4.13.A.1-l RESULTS Temperature and salinity measurements are shown in Figure 4.13.A-2 through 4.13.A-25.

_____ ____.e.. ________

-=-e ________

e_

CJ) 0::

w 1-0 2

~ 4 z

c I-6 a..

w a

8-10 2.8,

2.91 I J.0 I 2. 9 2.71 I 3.0 I 2.9 2.9 2.81 I 3.0

  • I -:

2.6 JAMES RIVER JAMESTOWN ISLAND TO SKIFFES CREEK "Tl I 3

  • 5.

lO I 2. 9.

C,

I 3. 5 Cl)

I 3. 0 r 7. 2

  • I 3
  • 5

_J::-

I 3.8 w

2.9 I 3. 8 I 3.6

):>

I -.

1*

N I 3.0 FLOOD I 3, 3

~~

I 7.2 I 3. 5 3.7 I 4.0 3.5 I -

I 3.6 I 2. 8 I 7. l I 3.9 6.9

  • I 3. 7 r-

~

I 3.0 3.8 3.0 0

0*5.

1*5 2

TE~A PERATURE (°C)

AT MONITORING STATIONS NAUTICAL MILES January, 1979

f---
---------~~-~-~~----~----...;;...... __

__j ______________

_j

JA~AES RIVER JAMESTOWN ISLAND TO SKIFFES CREEK 0.2 0.7 0

5 I 0.5 "Tl I

0.2 c.a I 0,4 C

2

0. 7*
0. 1 I I O. 2 I 0.3 I

0.5 CD I

CJ)

I 0.3 0.5 0:::

\\JJ L!J I

f I 0.7 I 0.]

):,

~-

0.2 I

I 0.4

\\JJ w 4 0.1 I Flood

'S I 0.2 I 0.3 I

0.1

'2 I 0.5 I

0.7 I 0.7 z

0.3 Ebb I...

c 6 0.4 I 0.3 I 0.2 0.7 I 0.6 I O. 2 I

I 0.5 CL I 0.7 w

Cl I 0.8 r...

8 0.2

~

'-/

I -

I 0.2 0,9 0

0*5 1*5 2

SALINITY

( ppt) 10 0.2 AT MONITORING STATIONS NAUTICAL MILES January, 1979 I

~.

e. _________________

e RIVER JAMESTOWN ISLAND TO SKIFFES CREEK Io. s.

0 o.4 I 0.5 IQ I 0.5 C

I O.6 (I) 2 0.21 I 0.2 I O.3 r 1.0.

I 0.6

~

Cf) 10.2 10.6 0.5 w

~

I 0.6

):,,

w I -*

I O.6 I

~

I-w FLOOD I 0.6

~ 4-

0. 11 I 0. 1 I O. 5 I

1.5 I 0. 7 0.7

~~

10.2 EBB,.

10.6 z

I 0. 7 0.2.

r:

I 0.6 I-6*

0.21 I 0. 1 I O. 5 I

1. 5 I 0. 7 CL

. I 0. 5 w

a 0.2 8*

0. l

.1 o.6

~

I -

I 0.5

2. l V

0.5 0.4 0

0*5.

1*5

  • 2 TEiA PERATURE (°C) 10
o. 1 NAUTICAL MILES AT MONITORING STAT.ION.S February, 1979

JA~AES RIVER JAMESTOWN ISLAND TO SKIFFES CREEK

2. 7
  • 0 5

I 2.0 "Tl -*

I O. 1 lO C

I 2.8 2

0.01 I O.0 I 1.0 CD I 0.3 I 2.2 J:-

(f)

I O O 1 I 2 *]

0::

I.,.)

w I 0. 2 12.8 I 3.9 l>

I l-

. u, w 4 0.Oa I 0. 0 Flood I 3.6 5

I 0. 3 I 1. 2

""'2...

I 2.2 3.0 I O. 1 Ebb 1,3. 2 z

I 4.5

c 6 0.01
0. 1 I O.0 I 0. 3 I 4. 3 I 1.2 I 2.2 a..

I 4.6 w

0 8

o.o.

I 4. 6 o.o I 0.3

1. 7 u

5-3 0.3 0

0*5 I

1*5 2

S.4L!NITY

( ppt) 10 o.o AT MONITORING STATIONS NAUTICAL MILES February, 1979

-r -----------~*------------.

JAMES RIVER JAMESTOWN ISLAND TO SKI FFES CREEK 0

"Tl -*

18.9 lO C

I 8,8

(\\)

2 9.01 I 8,9 I 8.!)

r 8. o I 8. 6

.i:-.

Cl)

19. l.

I 8.6 8.9 w

er I *8. 5

)::,

w I-I 8. 8 I

Q"\\

~

, 8,9 w

'.2: 4 9.01 I 9.0 I 8.9

~r20 I 8.0 I 8. 3 8.7 19.0 EBB'"

I 8.6 z

I 8. 4

r:

9.0 I 9.O I 8. 8 I-6*

9,01 I 8.9 I 8.0 I 8. 5 8.6 CL I -

w a

a-I 8.8 9.* :'()1 9.0 8.0 I -

-.J.

8.8 9.0 0

0*5.

1*5 2

TE~A PERATURE (°C) 10 NAUTICAL MILES AT MONITORING STATIONS March, 1979

\\

JA~AES RIVER JAMESTOWN ISLAND TO SKIFFES CREEK o.o*

0 5

I 0.0 I 0.0 lO C

10.0 2

0.0 I I O.0 I O,0.

Cl) 10.0 I 0.0

~

U)

I O.0 I 0,0

~

0::

\\JJ w

I 0.0 IO.0 I O.d

):>

I 1--

-...J w 4 0.0 I I O.0 Flood 10.0 10.0 I 0.0 0.0

..:a-

~

10.0 I O.0 1 o*.o.

Ebb z

I 0.0

,..~

c 6 0.0*,

0.0 I 0.0 10.0 10.* 0 f-I 0.0 I 0, 0 a_

1.0.0 w

0 8

o.o o.o 10.0 0,0. I

°"'

10.o 0.0 0

0*5 1*5 2

SALINfTY

( ppt) 10 o.o AT MONITORING STATto*Ns NAUTICAL MILES March, 1979

,--------------------------------'----------------l

e..

~

JAf\\~ES RIVER JAMESTOWN ISLAND TO SKI FFES CREEi<

I 13.2 13.5 0

I 13. 2 lO I 13.5.

C,

I 13. 4 Cl) 2*

13.41 113.4 I* 13.4

' 13. 1 I 13. 1

~

13.2 Cl) 113.4 I

1..,-)

0::

);>

w

13. 5 I 12.6 I 13.0 I

I 00 I-1 13. 4.

~4

13. 41 I 13.4 I 13. 4 FLOOD

.1 13. 1 I 13. 1 12.6 oG c:=:.

113.4 EBBi,,,

I 13. 1 z

I 1 J. 0

c
13. 31 13.4 113.4 I 13. 4 l I 13. 4 I 13. l I 13. 1
a.

I 13. 1 w

a I ]J.4 8

..l',

13. 41 13.4 I 13.4 13.1

'-.../

0 0*5.

1*5 2

TE~A PERATURE {°C) '

10 13.4 e I a.,.t I f AT MONITORING STATIONS.

NAUTICAL MILES Apr i 1, 1979

JAMES RIVER JAMESTOWN ISLAND TO SKIFFES CREEK

.o

.0 0

.o 5

I.o (C

I

  • ]

C -,

2

.0 I I.0 I.0 I.0 (I)

I.o

-'='"

(/)

1.0 I * ]

a::

w w

I.o I

  • 2 I. 1

)>

~-

. I

\\.0 w 4

.o t Flood I * ]

I.0 I.0

' c::::=

I.0 I ~0

.2 1.0 I. 0 z

Ebb I

  • 2.
c 6

.o I.0 I * ]

I-

.0 I I.O I.0 I.0 0...

w I

  • 1 0
  • a

.0 I

  • 2 0*

.0 I I.O

.0

~

0 0*5 1*5 2

SALINITY

(- p pt) 10

.o AT MONITORING STATIONS NAUTICAL MILES Apr i 1, 1979

  • ------------------------------L---------------1

. ---* -*-**-**-*****-***--* ---** *---*-**'*-----**** *********~-----------*---- *--* **-***. - **----**

I e

JAf\\AES RIVER JAMESTOWN ISLAND TO SKI FFES CREEK I 18.9

.o

19. 1 I 18,5 I 18, 3 lO.

C: -,

r 18.5

  • 18. 3 (I) 2
18. 51 I 18.4 I 18.3 I 18. 1

.i:-

(f)

I 18, 7 I 18, 1 w

0::

I 18;5

)>

w I 18, 3 I 18.2 I

I 18. 1 0

W4 17.9 FLOOD 18.2 2*

18.21 I 18. 1 I

I 18.2

~c?

I 17,9 I 18.0 18.3 EBB,,..

I 18.2 z

I 18.5

.18.0

c I 1 8. 1 I 17,9 I-6
18. 2' I 18. 1 I 18.0 I 17, 9 a..

I 18.0 w

a 8

18. 1 I 17.8 I -

I

18. 1 18.0

',./

0 0*5.

1*5 2

TE~~ PERATURE (oc) 10

18. 1 AT MONITORING STATIONS NAUTICAL MILES May, 1979

JAMES RIV-ER

. JAMESTOWN ISLAND TO SKIFFES CREEK

.3 0

5 I.2 I * ]

lO C

2 I* 2

  • ] I I * ]

I*

  • ]

I

  • 1 CD I.2

.i:,-

(.I)

I.2 I

  • 2 n::

w w

I

  • 1 I.5 I. 3

)>

I I-w 4

  • ] I
  • .2 I * ]

I

  • l Flood 5

""' c::::.:

I. l I

.5

.2 I.2 I

  • 3 z

Ebb I

  • 3
c 6

. l I

.2 I. l

. l I* 3

~

I

  • l I
  • l I.2 a_

I

  • 3 w

0 8

. l I. l I. 4 I

. l

--~

0 0*5 1*5 2

SALINITY

( ppt) 10

. l AT MONITORING STATIONS NAUTICAL MILES May, 1979

        • ------------------------------.:....--'---------___:_ ___ -1

e

--..---.---=*------------_::._ ____________

Jft~fv1ES RIVER JAMESTOWN ISLAND TO SKI FFES CREEK 22.".5 0

22.6

/*'

I 22.4 lO I 22.3 C

I 22.5 (1) 2 22.6 I I 22.6 I 22.6 r 22. l I 22.5 J::-

Cf)

I 22.6

  • I 22. 3 w

0::

122.4 I 22.4

)>

w I

I 22.5 N

~4 I 22.6

-22.6 1 I 22. 6 I 22.6

. FLOOD I 22. l 22.4

~~

I 22.5 I 22.6:

22.5 I 22.3 2

I -

i= 6

.22.6 I 22.6 I 22.6 I 22.6 I 22.6 I 22.0 I -

a.

I 22. 3 w

a 8-22.5 I -

22.6 I I 22.6

22.0 l>'

22.6 0

0*5.

1*5 2

t' TEMPERATURE (°C) 10 22.5 AT MONITORING STATIONS NAUTICAL MILES June, 1979

e JA fVlES RIVER JAMESTOWN ISLAND TO SKI FFES CREEK I

1.4 0

5 0.0 I 0.6 I 1. 4 "Tl -*

I 0.0 lO C:

I

]

  • 2 2

0.0 I I 0.0 I O. 3.

(1)

I 0.0 I 0. 6

.i::-

Cf)

  • 0.6 I 0.0 0::

w w

I O.0 I 0. 8 I 1. 5

)::,

I I-w I J. 3 w

4 0.0 I Flood 5

I 0.0 I 0.0

~~ I 0.3 I O.6 o.B I 0.0 Ebb 10.6 z

I -

r: 6 0.0 I 0.0 I 0.0 0.0 I 1. 3 I-I 0.0 I 0.3 I 0.6 a..

I 0.6 w

a 8

o.o I 2.0 0.0 I I 0.0 0.3

~

0.0 0

0*5 1*5 2

SALINITY

( ppt) 10 0.0 AT MONlTORING STATIONS NAUTICAL MILES June, 1979

e e

JAMES RIVER JAMESTOWN ISLAND TO SKIFFES CREEK I

3.6*

0 "Tl 10.8

  • 4.o c.o C: -,

r I 3.9 2

0.2 I 10.3 I 0. 6 I 1.6 CD 1 2.9

~

10.8 U)

I 3,6 w

~

w 10.8 I 3. 7

  • 4.8

)>

I w

I 4.0

~

4 0.2 I

,0.3 I 0.6 Flood

~

"'2.

I 1.8 I 3. 1 3.7

10. 8 Ebb I 4, 1 z
15. 1
c 6 0.3 I

o.8 IQ* 3

  • 4.2 IO. 7 I 1.9 13.2
n.

I l1. 5 w

Q 1.9 8

0.3 14.4

~

I IO. 7

,., v 0

0*5 I

1*5 2

SALINITY

( ppt) 10 AT MONITORING STATIONS NAUTIC~L MILES Ju 1 y, 1979

f

e.

I JAf\\~ES RIVER JAMESTOV/N ISLAND TO SK,LFFES 0

124.2 2

  • 24.21 124.2 I 24.]

I 24. 2 en 124. 1 24.2 0::

w I

~

~4

. 24.21

'124. 1 I 24. 1 FLOOD I 24. 1 124. 1

~~

z

c

. J 24.11

24. 1 124. 1 I 24. 1 I 24. 1 a.:

w

24. 1 a
24. 1 8

24.21 I -

0 0*5.

  • . I 1*5 2

10 NAUTICAL MILES e

CREEK I

24.0 "Tl I 24.0 lO C

I 24.]

(l)

I 24. 2

..i:-

I 24. 1

. w.

I 24. 1 I 24.0

)::,

I -

\\11 I 24. I I 24.2 24.1 I 24.]

  • 24.o I 24.]

I 24.2 I 24. l I 24. 1 0 !)

TE~A PERATURE (°C)

AT MONITORING STATIONS

  • July, 1979

r.

I 0

2

(/)

cc L!.J.

I-w "7

2:.q.

z

I:

I-6*

a.

w a

8 10 26.9 I 26.91 26.81

. 26.81 e

e e

RIVER JAMESTOWN ISLAND TO SKI FFES CREEi<

27.5

-n 127. l I 27. l lO C -,

r 26. 8' 127.0 CD I 26.9 I 26. 8 I 26.9

.i::-

I 26. 8 I 26.9 w

126.9

)>

I 27. l I 26. 7 I.....

Cl' 126.8 I 26.9 I 26. 8 FLOOD I 26.8 oC~

126.9 26.9 I 26. 8

.EBB,-

I 26. 7 26.6 26.7 126.9 I 26. 7

  • 26.9 126. 7 I 26.8 126*.8 I -

26.8 26.7 i 26. 8 126.9 I -

-.J

-.J 0

0*5.

1*5 2

TE~A PERATURE (°C) 26.6 AT MONITORING STATIONS NAUTICAL MILES August, 1979

e e

JArv:ES RIVER JAMESTOWN ISLAND TO SKI FFES CREEK 8

I s/1.7 4.4

  • o

(

,r I 2.0 1.5 I 4. 7 lO I]. 7 C,

I 4.5 (1) 2 l.0 I I l. 2 I 2. 0 I 2. 7 I 4.0

-l=".

CJ) 11.5 I 11. 2 w

cc 15.4

x:,

w I I

  • 7 I 4. 5 I

-...J w 4 l.2 I

I l.3 Flood I 4. 5

~

I 2.0 I 2. 7

~c?..

14. l 4.6 I J.6 Ebb I 4. 6 z
  • 6.6
i: 6
l. 3 I
l. 7 11.4
  • 4.7 I-I 2.0 I 2. 8
14. l a..

I 5. 0 w

Cl 8

1.4 1.4 14.9 I

1 *2.0 3.0

~

0 0*5 1*5 2

SALINITY

( ppt) 10

l. 4 AT MONITORING STATIONS NAUTICAL MILES August, 1979

=--* ---------=--------------,,

I 0

25.0

25. 1

/*'

I 25. 3 2

24.9 I I 24.8 en 125.0 a::

L!J I 25.3 W4

~

24.8 I I 24.8 125.0 z

I 25.0 I 24.8 I-6. 24.8 I

a.

w a

8-I -

24.7 10 24.7 24.7 JAMES RIVER JAMESTOWN

,ISLAND TO SKI FFES CREEK 125. 1 r 25. 3 I 25.2 125.0 FLOOD I 25.0 I 25.]

.c?

EBB"'

I 24.9 I 25.0 I 25.]

25. 1 I 24.9 25.0
  • 24.9 25.0 0

0*5.

1*5 2

125.4 I 25. 3 25.2 I 25. 2 I 25. l I 25. 3 I 25. 3 I 25.]

I 25. l I

6

25.

I 25.6 I 25.4 125.4 TE~A PERATURE (°C)

\\0 C,

(1)

-I=".....

vJ

)::,

I....

co

.A -

NAUTICAL MILES AT MONITORING STATIONS September, 1979

e e

JAMES RIVER JAMESTOWN ISLAND TO SKI FFES CREEK O.l-0 5

lO 10.0

  • C I 0.]

(1) 2 0.0 I

  • o.o i O.o I O.]

I O * ]

.i::-.

(J) 10.o I O.]

w a:::

IO.] *

)>

w 10.0 I O. ]

I I-

. \\.D w 4 0.0 I

,o.o I O.0 Flood I O.]

~

""'c?..

I 0. 1 I 0. 1

0. l 10.0 Ebb I O.]

z IQ.]

t: 6 0.0 I o.o 10.0 I O.0 I 0. l I-I O.]

I O.]

a..

I O. 1 w

0 8

o.o IO. 1 I -

I 0.0 0.1

0. 1 0.0
0. l SALINITY

( ppt) 0 0*5 1*5 2

10 o.o AT MON!TORING STATIONS NAUTICAL MILES September, 1979

e e

JAi\\~ ES RIVER JAMESTOWN ISLAND TO S Kl FFES CREEK 17~3 0

4 I 17,3 17.4 lO I 17,9 C: -,

118.4 Cll 2

18. I 1 I 18.2 I 18. 2 r 17. 6 I 17, 8

.l=-

(/)

I 17,9 118.2 18.0 w

~

)::,

w I 17. 4 I 17, 3 I

I -

N I-0 w

18. I 1 I 18. 2.

FLOOD 118.4

~4 I 18. 1

~~

I 17. 6 I 17. 7 17.4 I 18. 2 I 17,9

  • 2 17.8 I 17, 3

~-e

  • 18. 11
18. 1 118. 4 I 18. 1 I 18. 1 I 17,5 I 17, 7 Cl.

I -

w

18. 1

~'

a 118. 4 r"',

a I -

18. I I 18. I 17,5
  • v
18. I 0

0*5.

1*5 2

TE~A PERATURE (°C) 10 NAUTICAL MILES AT MONITORING STATIONS October, 1979

e JA~AES RIVER JAMESTOWN ISLAND TO SKI FFES CREEK

.0 0

-n -*

I

  • 0

<O C

I.Q CD 2

  • 0 I I
  • 0 I
  • Q I
  • 0 I
  • 0

.i:-.

(/)

I. Q

  • .o

~

\\,J a::

w I.0 I.o

)>

I

  • 0 I

N I-I, 0

~

w 4

.0 I I

  • 0 Flood

'S I

  • 0 I.0

~~

I.o

.0 I. 0 I, 0 Ebb z

I,0

i:: 6

.0 I

.o I

  • 0 I.0 I
  • 0 I
  • 0 I, 0 a_
1. 0 w

Cl 8

.o I

  • 0
  • 0 I I
  • 0

.o

';J'

~

0 0*5 1*5 2

SAL!NITY

( ppt) 10

.o AT *MONITORING STATIONS NAUTICAL MILES October, 1979

I :

JAMES RIVER I

JAMESTOWN ISLAND TO SKIFFES CREEK I

o.8.

0 I 0,8

'Tl -*

I O.0 lO I 0,4 C:'

2 I 0,0 I 0.0 CD 0.0 I I 0,Q I 0,2

.i::-

I 0, 4 (J)

I 0.0 w

0::

I 0.8 w

I o.s

):>

I O. 0 I

I-N I 0,4 N

w 4 0,0 I I 0,0 I 0.0 Flood s

"'c::? ~

I O.O I 0.2 0.5

~

IO.0 Ebb I 0.4 z

I 0, 8

c 6 0.0 I 0,4 i-0,0 I I O.0 I O.0 I O.0 I 0,2 a..

0.2 I 0, 4 w

o.o 0

8 0.0 I 0,4 0,0 I I O. O

~

0.0 o.o SALINITY

( ppt) o*

0*5 1*5

'2 10 NAUTICAL MILES AT MONITORING STATIONS November, 1979

  • . -L.. \\-

'¥S

.** <* *. -~{-***'*g,-. ~-.i--+--""% ** c:

.a.--... J:J.,-*>>-**.

-**.a..,.. -, *.,1.. ~~*,,-:

.*,.=

..... ~=~

e

______..;;;; ------------------------=-----------------------

e JAfv1 ES RIVER JAMESTOWN ISLAND TO SKI FFES CREEK I 13. 6 0

13.2 I ]3.6

  • .. lC I 1 J.2 C:

. ""I I 13. 9 (1) 2

13. 21 I 13. 2 I 13.11

' 13. 4 I 13.6

.I:""

U)

I 13. 1 I 13. 8 w

0::

13.2 I 13. 4

);::,

w 114. 3 I

N w

~4

13. 21 I 13.4 FLOOD I 13.9 I 13. 2

~c?

I 13.4 I 13

  • 5 14.3 I 13.0 EBB>

I 13. 8 z

I 13.5*

13.0 13~6

c I 13. 7 l-6
13. 21

,

  • 13. 2 I -l-3 )t I 13. 1 I 13. 5 Q.;,

I -

w 13.2 a

13.5 8-I 13. 7

. 13. 2i I 13. 4.

~

l3.2 13.4 0

0*5.

1*5 2

TE~~ PERATURE (°C) 10

.., AT MONITORING STATIONS NAUTICAL MILES November, 1979

I e

JAfV1ES RIVER JAMESTOWN ISLAND TO SKIFFES CREEi<

I 6.0*

0 15.9 c.o I 7. 1 C,

I 7,]

(1) 2 ~

6.9 I I 6.9 I 7, J r 6. 9

  • I 7,0

..i::-

17,4

~

{f)

I 7.0 w

0:::

15,9

):>

w I 7 ~ 1 I 7. 7 I

N r-

..i::-

1 7. 1 w

fl 6,9 I I 4.9 I 7. 1 FLOOD I 6.9 2 4 -

-41 c::::

I 7.0 7.7 I 7.0 EBB,..

17.4 2

15.9 7.0.

7.4 I

17. 1 l-6 6.9 I I 5.6 I 7. l I 6.9 I 7.0 a..

I -*

w a

I 7, l 8*

6,9 I 7.0 I 7. l I 6,9 7.0

()

0*5.

1*5 2

TE~APERATURE (°C) 10

'-'--1-.:

AT MONITORING STATIONS NAUTICAL MILES December, 1979

,-------------------~-----.,-------

JA~AES RIVER JAMESTOWN ISLAND TO SKIFFES CREEK

.o 0

5 1.0 I.o lO

.o C

I.0 2

,0 I I,0

.o CD I

I.o I, 0 (J)

I I,0

.o a::

\\.,J LIJ I.0 I, 0 I.o

J>

~-

I N

w 4 I.0.

u,

..* 0 I I 1.2 I.o Flood I

  • 0

.. 2 1,0

.o I, 0 I,0 z

Ebb I

  • 0.
c 6

,0 I

.0 I

I,0 i-

,9 I.o I

  • 0 I, 0 a..

I

  • 0 w

Cl 8

.o I.0

, 0 I I.0

.0

~

'V 0

0*5 1*5 2

SALINITY

( ppt) 10-

.o NAUTICAL AT MONITORING STATIONS MILES December, 1979

e Figure 4.13.A-1 TEMPERATURE AND SALINITY MONITORING STATIONS A,

,, 6 '

,~

~

A 8

~

7 I,.,,'

'-A 5

\\

¢{""

HOG

\\

, 9 ISLAUD I

\\

I

~10

\\ \\

\\ '

\\

\\

~-----""'6.---L-..6.-----~

4 3

2 I

O 2 Nautical Miles 1.,1,.,1'-'--'-'-L...i...L..1-.1...-----'-------'

JAMES RIVER 1000 O

1000 2000 3000 Yards

.e LEGEND: 6.

Monthly Salinity - Temperature Profile Station o

Near Surface Temperature Moni~oring Station Boat Cruise t

-N-I

e 4.13.A.2 4.13.A.2.1 CONTINUOUS WATER TEMPERATURE MONITORING METHODS Mfd-depth water temperature is measured in the intake canal at the high-level screens and in the discharge canal at the groin as illustrated in Figu~e 4.13.A-2.

Temperatures are recorded continuously on Taylor circular chart recorders located at each point.

Charts are changed weekly and temperatures digitized using a Hewlett-Packard 9864A digitizer.

4.13.A,2.2 RESULTS Monthly mean values of the daily high, mean, and low values at each location are shown in Table 4.13.A.2-1.

e e

e TABLE 4.13.A.2-l JAMES RIVEP. RIVER TEMPERATURE DATA VALUtS ARE MEANS OF DAILY HIGH, MEAH, AND LOW VALUES

~--------------------------------------- YEAR-79 MONTH-1 -----------------------------------------

TYPE INTAKES HIGH 6.4 MEAN S.6 LOW 4.9


YEAR-79 MONTH=2 TYPE INTAKES HIGH 3.0 MEAN 2.2 LOW l.4 DISCH 13.8 12.8 12.0 DISCH 10.l 9.0 8.l


YEAR-79 MONTH-3 ---------------* ----- _-------------------

TYPE HIGH MEAN LOW INTAKES 12.0 l0.6 9.3 DISCH lS.8 14.3 12.9


YEAR-79 MONTH=4 -----------------------------------------

TYPE HIGH.

MEAN LOW INTAKES 16.9 lS.S 14.4 DISCH 17.0 lS.6 14.S


-------------------- YEAR-79 MOHTH=S --- ---------------------------------.---

TYPE HIGH

!1EAN LOW


YEAR-79 TYPE HIGH MEAN LOW INTAKES 22.6 21.1 20.l MOHTH=6 INTAKES

-25.3 23.8 22.5 DISCH 22.7 21.2 20.l DISCH 2S.4 2~.q 22.6

e e

e TABLE 4.13.A.2-l CCONTIHUEDI JAMES RIVER RIVER TEMPERATURE D~TA VALUE$ ARE MEANS OF DAILY ~IGH, M~AN, AND LOW VALUES ANNUAL REPORT FOR 1979


-----. ---------------------------- YEAR-79 MQNTH-7 ---- *------------------------------------

TYPE HIGH MEAN LOW INTAKES 27.9 26.6 25.6 DISCH 28.0 26.8 26.0


YEAR-79 MONTH-8 -----------------------------------------

TYPE HIGH MEAN LOW


J-------- YEAR-79 TYPE HIGH MEAN LOW INTAKES 28.4 27.2 26.2 DISCH 28.8 27.7 26.8 MONTH-9 ---. -----------.-------------------------

INTAKES 24.8 23.9 23.1 DISCH 25.5 24.5 23.8


YEAR-79 MONTH-10 ----------------------------------------

TYPE HIGH MEAN LOW INTAKES 18.6

  • 17.6 16.6 DISCH 20.5 19.4 18.3

YEAR-79 MONTH-ll ----------------------------------------

TYPE HIGH MEAN LOW INTAKES 14.5 13.7 12.9 DISCH 22.4 21.5 20.7


YEAR-79 MONTH-12 ----------------------------------------

TYPE HIGH MEAN LOW INTAKES 8.1 7.4 6.5 DISCH 13.4 12.4 11.4

e 4.13.A.2~3 Discussion There are very few preoperational data for comparison with 1979 values.

However, comparisons of the data in Table 4.13.A.2.2-1 do not show any major differences in intake temperatures.

Due to reduced station operations, discharge temperatures in 1979.were generally lower than those of other postoperational years.

Data for other postoperational years may be found in earlier operating reports.

e 4.13.A.3 CONDENSER-COOLING SYSTEM CHLORINATION Chlorine was not used in condenser cleaning_ and therefore no monitoring was performed.

4. 13.A.4 CHEMICAL RELEASES TO THE COOLING SYSTEM These data are reported monthly.

e 4.13. B 4.13.B.1 4.13.B.1.A FI SH SAMPLING MONTHLY BEACH DEINE AND OTTER TRAWL SAMPLING METHODS Sampling is conducted monthly at one otter trawl station located off the low level intakes and at two beach seining stations located immediately

,upstream (Intake N) and downstream (Intake S) of the low-level intakes (Figure 4.13.A.2-2).

The trawl sample is taken by towing a 3.1 m (diameter at mouth) trawl of 6.4 mm bar mesh in the cod for 10 minutes starting just off tile low-level intake structure with an ENE heading.

The beach seine samples are taken using a 15.2 m wide x 1.8 m deep of 6.4 mm bar mesh seine that is first stretched perpendicular to the shore, hauled 92 m and then brought ashore.

Samples are usually preserved immediately and then taken to the laboratory for identification and measuring.

Occasionally, when large or unusual fishes are caught, their catch is noted on the field sheet and they are immediately released.

4.13.B.1.B RESULTS Data for the monthly seine and trawl samples are shown in Tables 4.13.B.2.B-1 to 4.13.B.2.B-12.

A total column for the two seine stations is provided also.

The tables show the catch for each species, the total catch of all species, the number of species for each station, and the diversity estimates H-Prime, Evenness, and Richness.

  • e CHIPPOK£S 0

2 I

O 2

3 Figure 4.13.A.2-2*

BIOLOGICAL SAMPLE STATIONS FLOOD. *~

EBB Nautical Miles

,JAMES RIVER*

111.... u....

11~u..... 11.____,.__._ __

,1...-_-J1 K llomet ers 9

0 Trawl D Seine t

-N-I

e Table 4.13.B.2.B-1 SURRY PO~ER STATION CATCH BY SPECIES ANO DIVERSITY ESTIMATES BY HONTH FOR 1979 PLEASE SEE FIGURE 4.13.8.2-2 FOR STATION LOCATIONS

  • -------------------------------------------- YEAP.-79 HONTH-1 ------------- *-.-----------------------------~

SPECIES INTAKE_S INTAKE_N TRAWL TOTAL ALOSA AESTIVALIS 1.0000 1.0000 2.0000 DOROSONA CEPEOIANUH

1. 0000 1.0000 ICTALURUS CATUS 1.0000 ICTALURUS PUNCTATUS 4.0000 HENIDIA BERYLLINA 12.0000 2.0000 14.0000 HEHIDIA NE~IIDIA 1.0000 1.0000 HORONE AMERICANA 1.0000 16.0000 1.0000 HOP.mlE SAXATILIS 1.0000 TRINECTES HACULATUS 314.0000 SPECIES 5.0000 2.0000 5.0000 5.0000 TOTAL FISH 16.0000 3.0000 336.* 0000 19.0000 H_PP.IHE 1.3113 0.9183 0.4265 1.3372 EVENNESS 0.5647 0.9183 0.1837 0.5759 RICHNESS 1.0000 0.6309 0.4766 0.9416

e Table 4.13.B.2.B-2.

SURRY POWER STATiml CATCH BY SPECIES ANO DIVERSITY ESTIMATES BY NONTH FOR 1979 PLEASE SEE FIGURE 4.13.B.2-2 FOR STATION LOCATIONS

  • (3L)
  • -------------------------------------------- YEAR=79 NONTH-2 --------------------------------------------*

SPECIES DOROSOMA CEPEOIANUN ICTALURUS PmlCTATUS MENIOIA BERYLLINA MORONE AMERICANA NC~ONE SAXATILIS TRINECTES MACULATUS SPECIES TOTAL FISH H_PRINE EVENNESS RICHNESS INTAKE_S 1.0000

. l.0000 1.0000 0.0000 0.0000 1.0000 INTAKE_N TRAWL 2.0000 9.0000 5.0000 4.0000 12.0000 5.0000 32.0000 2.0888 0.8996 0.8000 TOTAL 1.0000 1.0000 1.0000 0.0000 0.0000 l.0000

e Table 4.13.B.2.B-3 SURRY POWER STATION CATCH BY SPECIES AND DIVERSITY ESTIMATES BY NONTH FOR 1979 PLEASE SEE FIGURE 4.13.B.2-2 FOR STATION LOCATIONS


YEAR=79 NONTH-4. ---------------- ----------------------------*

SPECIES INTAKE_S ItHAKE_N TRAWL TOTAL ALOSA AESTIVALIS 2.0000 1.0000 3.0000 ANCHOA NITCHILLI 25.0000 11.0000 36.000.0 ANGUILLA ROSTP.ATA 3.0000 FUNOULUS HETEP.OCLITUS 9.0000 1.0000 10.0000 ICTALURUS CATUS 1.0000 ICTALUP.US PUNCTATUS 1.0000 LEIOSTONUS XANTHURUS 2.0000 LEPOHIS HACP.OCHIRUS 1.0000 1.0000 NENIDIA BERYLLINA 27.0000 74.0000 101.0000 HENIDIA tlENIDIA 25.0000 10.0000 35.0000 NICROPOGON utlDULATUS

1. 0000 NORONE ANEP.ICAtlA 2.0000 11.0000 3.0000 13.0000 NOTP.OPIS HUDSONIUS 10.0000
  • s *. 0000 15.0000 TP.INECTES HACULATUS 112.0000 SPECIES 7.0000 8.0000 7.0000 8.0000 TOTAL FISH 100.0000 114.0000 123.0000 214.0000 H_PP.IHE 2.3806
l. 7413 0.6504 2.2143 EVENNESS 0.8480 0.5804 0.2317 0.7381 RICHNESS 0.9031 1.0245 0.8642 0.9042

e Table 4.13.B.z~s-4 SUP.RY POWER STATION CATCH BY SPECIES ANO DIVERSITY ESTIMATES BY NONTH FOR 1979 PLEASE SEE FIGURE 4.13.8.2-2 FOR STATION LOCATIONS


YEAR=79 NONTH-5 ----------------------------------------------

SPECIES INTAKE_S INTAKE_H TRAWL T0"1:AL ANGUILLA ROSTRATA 2.0000 BREVOORTIA TYRANNUS 160.0000 160.0000 FUNDULUS HETEP.OCLITUS 5.0000 9.0000 14.0000 ICTALUP.US CATUS 3.0000 ICTALUP.US PU~lCTATUS 1.0000 LEIOSTONUS XANTHUP.US 998.0000 8.0000 18.0000 1006.0000 NEHBRAS NAP.TnlICA 1.0000 1.0000 NEMIOIA BERYLLitlA 3.0000 3.0000 HICROPOGCN UNDULATUS 1.0000 NORCNE AHEP. ICMIA 3.0000 6.0000 3.0000 PARALICHTHYS DENTATUS

l. 0000 l.0000 TRnlECTES NACULATUS 221.0000 e

SPECIES 5.0000 4.0000 7.0000 7.0000 TOTAL FISH 1167.0000 21.0000 252.0000 1188.0000 H_PRUIE 0.6506 1.6645 0.7612

0. 7290 EVEMNESS 0.2802 0.8322 0.2711 0.2597 RICHNESS 0.3926 0.6830 0.7521 0.5874

e Table 4. 13.B.2.B-5 SURRY POWER STATiml CATCH BY SPECIES ANO DIVERSITY EST!HATES BY HONTH FOR 1979 PLEASE SEE FIGURE 4.13.B.2-2 FOR STATION LOCATIONS

  • -------------------------------------------- YEAR=79 HONTH-6 ----------------------------------------------

SPECIES INTAKE_S INTAKE_N TRAWL TOTAL AtlCHOA HITCHILLI 17.0000 3.0000 20.0000 ANGUILLA ROSTRATA 1.0000 BREVOORTIA TYRANNUS

l. 0000 5.0000 6.0000 DOROSONA CEPEDIANUH
l. 0000 l.0000 FUNO'JLUS HETEROCLITUS 1.0000 1.0000 HYBOGtlATHUS tlUCHALIS 2.0000 2.0000 ICTALUfWS CATUS 1.0000 4.0000
l. 0000 ICTALURUS NEBULOSUS 4.0000 4.0000 ICTALURUS PUNCTATUS 5.0000 2.0000 5.0000 LEIOSTONUS XANTHURUS 111.0000 149.0000 13.0000 260.0000 HENIDIA BERYLLINA 2.0000 1.0000 3.0000 HICROPOGON UNDULATUS 2.0000 3.0000 67.0000 5.0000 HOP.ONE AHERICANA 3.0000 3.0000 2.0000 6.0000 HORotlE SAXATILIS 5.0000 5.0000 10.0000 t:OTROPIS HUDSmlIUS 2.0000 2.0000 TRINECTES HACULATUS 54.0000 SPECIES 13.0000 8.0000 7.0000 14.0000 TOTAL FISH 156.0000 170.0000 143.0000 326.0000 H_PRIHE l.7236 0.8615 l.7242 1.3657 EVENNESS 0.4658 0.2872 0.6142 0.3537 RICHNESS l.6471 0.9447 0.8380 l.5571

e Table 4. 13.B.2.B-6 SURRY POWER STATION CATCH BY SPECIES AND DIVERSITY ESTIMATES BY HONTH FOR 1979 PLEASE SEE FIGURE 4.13.B.2-2 FOR STATION LOCATIONS


*----------. --------------------------- YEAR=79 HONTH-3 ---------------------------------------------*

SPECIES INTAKE_S INTAKE_N TRAWL' TOTAL ANGUILLA ROSTRATA

l. 0000 CYPRnlUS CARPIO 1.0000 l.0000 HYBOGNATHUS NUCHALIS
l. 0000 1.0000 ICTALURUS CATUS 2.0000 ICTALURUS NEBULOSUS
l. 0000 1.0000 ICTALURUS PUNCTATUS 9.0000 HENIDIA BERYLLINA 7.0000 7.0000 14.0000 HORONE ANERICANA
l. 0000 1.0000 NUGIL CEPHALUS 1.0000 1.0000 NOTROPIS HUDSONIUS 2.0000 9.0000 11.0000 TRINECTES HACULATUS 72.0000 SPECIES 4.0000 5.0000 4.0000 7.0000 TOTAL FISH 11.0000 19.0000 84.0000 30.0000 H_PRINE l.4911
l. 7121 0.7404 1.8617 EVENNESS
o. 74.'>6 0.7374 0.3702 0.6631 RICHNESS 0.8672
  • o.9416 0.4693 1.22'.!8

Table 4. 13.B.2.B-7 SURRY POWER STATION CATCH BY SPECIES ANO DIVERSITY EST!HATES BY HONTH FOR 1979 PLEASE SEE FIGURE 4.13.B.2-2 FOR STATION LOCATIONS


YEAR=79 HONTH-7 --------------------~------------------------

SPECIES INTAKE_S INTAKE_N TRAWL TOTAL CYNOSCION REGALIS 2.0000 CYPRINUS CARPIO

  • 2. 0000 DOROSOHA CEPEOIANUH 1.0000 1.0000 ICTALURUS CATUS 1.0000 ICTALURUS NEBULOSUS 3.0000 3.0000 ICTALURUS PUNCTATUS 7.0000
1. 0000 2.0000 8.0000 LEIOSTOHUS XAtlTHUP.US 128.0000 112.0000 7.0000 240.0000 NICROPOGON UNDULATUS 16.0000 1.0000 4.0000 17.0000 NORotlE AMERICANA 2.0000
1. 0000 2.0000 NORONE SAXATILIS
1. 0000
1. 0000 tlOTP.OPIS HUDSONIUS
l. 0000 l.0000 TRINECTES NACULATUS 31.0000 SPECIES 5.0000 6.0000 8.0000 8.0000 TOTAL FISH 155.0000 118.0000 50.0000 273.0000 H_PRIHE 0.9251 0.4045 l.8992 0.7745 EVENNESS 0.3984 0.1565 0.6331 0.2582 RICHNESS 0.5497 0.7265 1.2403 0.8650

Table 4.13.B.2.B-8 SURRY POWER STATION CATCH BY SPECIES AND DIVERSITY ESTIMATES BY MONTH FOR 1979 PLEASE SEE FIGURE 4.13.B.2-2 FOR STATIC~! LOCATIONS

  • -------------------------------------------- YEAR=79 MONTH-a----------------------------------------------

SPECIES INTAKE_S INTAKE_N TRAWL TOTAL ANCHOA NITCHILLI 50.0000 2.0000

l. 0000 52.0000 ICTALUP.US CATUS 4.0000 ICTALURUS NEBULOSUS 3.0000 3.0000 ICTALURUS PUNCTATUS 3._0000 3.0000 LEIOSTONUS XAMTHURUS 35.0000 4.0000 29.0000 39.0000 HENIDIA HEHIDIA 2.0000 3.0000 5.0000 NICP.OPOGCN UNDULATUS 18.0000 21.0000 18.0000 HCP.ONE AMERICANA 1.0000 1.0000 1.0000 HORONE SAXATILIS l.0000 1.0000 HUGIL CEPHALUS 2.0000 2.0000 NOTROPIS HUDSONIUS 1.0000 l.0000 TP.INECTES NACULATUS 32.0000 SPECIES 9.0000 4.0000 6.0000 10.0000 TOTAL FISH 114.0000 ll.0000 88.0000 125.0000 H_PR!HE 2.0234 l.9363 1.9012 2.1599 EVE~l~IESS 0.6383 0.9681 0.7355 0.6502 RICHNESS 1.1708 0.8672 0.7741 1.2920

Table 4.13.B.2.B-9 SURRY POWER STATim~

-CATCH BY SPECIES ANO DIVERSITY ESTIHATES BY HONTH FOR 1979 PLEASE SEE FIGURE 4.13.B.2-2 FOR STATION LOCATIONS


YEAR=79 HONTH-9 ----------------------------~ --------------~

SPECIES INTAKE_S INTAKE_N TRAWL TOTAL AtlCHOA MITCHILLI 12.0000 12.0000 ANGUILLA ROSTRATA l.0000 CYPRINUS CARPIO 1.0000 1.0000 ICTALURUS CATUS 4.0000 ICTALURUS NEBULOSUS 2.0000 2.0000 ICTALURUS PUNCTATUS

l. 0000 LEIOSTOHUS XANTHURUS
21. 0000 17.0000 10.0000 38.0000 HICROPOGON UNOULATUS 6.0000 l.0000 19.0000 7.0000 HORONE AHERICANA 6.0000 3*. 0000 l.0000 9.0000 NORONE SAXATILIS 3.0000 l.0000 4.0000 TRINECTES MACULATUS
l. 0000 80.0000 1.0000 SPECIES 6.0000 6.0000 7.0000 8.0000 TOTAL FISH 39.0000 35.0000 116.0000 74.0000 H_PRIME 1.9517 l.7790 1.4469 2.1470 EVENNESS 0.7550 0.6882 0.5154
o. 7157 RICHNESS 0.9460 0.9743 0.8749 l.1273

Table 4.13.B.2.B-10 SURRY POWER STATIOH CATCH BY SF!ECIES ANO DIVERSITY ESTINATES BY HONTH FOR 1979 PLEASE SEE FIGURE 4.13.B.2-2 FOP. STATION LOCATIONS


------------------- YEAR-79 HONTH-10 --------------------------------------------,

SPECIES INTAKE_S INTAKE_N TRAWL TOTAL ANCHOA HITCHILLI 8.0000 47.0000 55.0000 BREVOORTIA TYP.ANNUS 2.0000 2.0000 DOP.OSOMA CEPEDIANUM 3.0000 5.0000 8.0000 DOROSONA PETENENSE l.0000

l. 0000 FU~lDULUS HETEP.OCLITUS l.0000 1.0000 HYBOGNATHUS NUCHALIS 5.0000 5.0000 LEIOSTOHUS XANTHURUS 4.0000 4.0000 l.0000 8.0000 HENBRAS HARTINICA 3.0000 l.0000 4.0000 HENIDIA BERYLLIMA 2.0000 5.0000 7.0000 HENIOIA NENIDIA 3.0000 3.0000 HICP.OPOGON UNDULATUS 2.0000 2.0000 HORONE AMERICANA 3.0000 6.0000 9.0000 HORmlE SAXATILIS 1.0000 1.0000 NOTROPIS HUDSONIUS.

2.0000 6.0000 8.0000 TP.INECTES HACULATUS 76.0000 SPECIES 8.0000 13.0000 2.0000 14.0000 TOTAL FISH 27.0000 87.0000 77.0000 114. 0000 H_PRIHE 2.8192 2.5157 0.1000 2.7406 EVENNESS 0.9397 0.6798 0.1000

o. 7198 RICHNESS l.4722 l.8625 0.1596 1.9026
e.

Table 4. 13.B.2.B-11 SURRY POWER STATION CATCH BY SPECIES AND DIVERSITY ESTIMATES BY HONTH FOR 1979 PLEASE SEE FIGURE 4.13.B.2-2 FOR STATION LOCATIONS


*--------- YEAR=79 HONTH-11 ---*------------------- *------*-------------:

SPECIES INTAKE_S INTAKE_N TRAWL TOTAL ALOSA PSEUDOHARENGUS 1.0000 ANCHOA HITCHILLI 6.0000 15.0000

l. 0000 21.oooci ANGUILLA ROSTP.ATA 1.0000 BREVOORTIA TYRANNUS 1.0000 1.0000 HYBOGNATHUS tlUCHALIS 2.0000 2.0000 ICTALURUS CATUS 17.0000 ICTALURUS PUNCTATUS i.0000 1.0000 3.0000 2.0000 LEIOSTOHUS XAMTHURUS 4.0000 20.0000 31.0000 24.0000 HEtlIDIA BERYLLUIA 3.0000 6.0000 9.0000 HICROPOGON UNDULATUS 3.0000 3.0000 32.0000 6.0000 HORONE AHERICANA 16.0000 3.0000 16.0000 NOTP.OPIS HUDSONIUS 5.0000 2.0000 7.0000 TRINECTES MACULATUS 30.0000 SPECIES 6.0000 9.0000 9.0000 9.0000 TOTAL FISH 22.0000 66.0000 119.0000 88.0000 H_PRINE 2.4308 2.5094 2.3588 2.6643 EVENNESS 0.9404 0.7916 0.7441 0.8405 RICHNESS l.1212 l.3235 l.1603 1.2385

Table 4.13.B.2.B-12 SURRY PO~EF! STATION CATCH BY SPECIES ANO DIVERSITY ESTIHATES BY HONTH FOR 1979 PLEASE SEE FIGURE 4.13.B.2-2 FOR STATION LOCATIONS


-------- ----- YEAP.=79 MOHTH-12 ---------------------------------------------

SPECIES ntTAKE_S INTAKE_N TRAWL TOTAL ANCHOA MITCHILLI 9.0000 9.0000 CYPF!UIUS CARPIO 1.0000 1.0000 OOF!OSOHA CEPEOIANUM l.0000 2.0000 3.0000 HYBOGNATHUS NUCHALIS 3.0000 3.0000 ICTALUF!US CATUS 4.0000 ICTALURUS PUNCTATUS l.0000 LEIOSTOHUS XANTHURUS 21.000.0 MENIDIA BERYLLINA 2.0000 2.0000 MICROPOGON UNOULATUS 30.0000 MOP.CME AMERICANA

l. 0000 1.0000 5.0000 2.0000 MO~ONE SAXATILIS 1.0000 NOTF!OPIS HUDSCNIUS 5.0000 4.0000 9.0000 TF!INECTES MACULATUS 273.0000 SPECIES 6.0000 4.0000 7.0000 7.0QOO TOTAL FISH

,19.0000 10.0000 335.0000 29.0000 H_PRIME 2.0301 1.8464 1.0197 2.4246 EVENNESS

  • 0.7853 0.9232 0.3632 0.8637 RICH~lESS 1.1770 0.9031
o. 7153 l.2351

4.13,B,2 4.13.B.2.A ADDITIONAL SEINE AND TRAWL SAMPLING REQUIREMENTS (Y1)

T.S.4.13.B requires additional samples at the stations (described in 4.13.B,2.A under the following circumstances:

(1)

If survival of fishes impinged on the Ristroph Traveling Screens falls below 75% on a given screen-sample day, seine and travel samples must be taken daily until survival rises above 75%;

(2)

If these screens malfunction or break down, weekly seine and trawl samples must be taken until normal operation resumes.

No daily low-level screen samples had less than 75% survival so no daily samples were taken.

During the week of February 18 the low-level screens broke down, a deviation report was filed, and seine and trawl samples were taken.

The screens returned to operation during the following week so the sample was used for the regular monthly sample as well.

No other situations required additional sampling.

4.13.s.3

  • DISCUSSION The data collected in the seine and trawl samples may probably best be analyzed by inspection of preoperational, earlier postoperational, and current samples from these stations.

Table 4.13.B.3-lA and B show the relative abundance of each species for each gear type during the preop.erational period, the postoperational period prior to 1979, and during 1979.

In order to reduce some of the variability caused by the different sample sizes, monthly means were computed for each period.

These means were then summed for the period and percentages calculated.

As might be expected, both the seine and trawl data show considerable variation among the minor species.

Although some species show an apparent decline (e.g., Alosa aestival is in the seine), and others increase (Leiostomus xanthurus e

in the seine), sti 11 others rise and then fal 1 in numbers ca_ught (Brevoortia tyrannus in the seine).

At the most, these variations can be con.;idered to reflect normal estuarine variability coupled with the effects of the recent severe winters of 1977, 1978, and 1979 and not due to power station operations.

Table 4.13.B~J~lA COMPOSITION OF SAMPLES DURING PRE-OPERATION (PRE PCT), POST-OPERATION PRIOR TO 1979 CPOST_PCTJ, A~~ THE CURRENT-YEAR C_79_PCT)

VALUES ARE EXPRESSED AS PERCENTAGES SEE TEXT FOR FURTHER EXPLANATION


GEAR=MONTHLY SEINE----------------------------------------

SPECIES PRE_PCT ALOSA AESTIVALIS 8.8 ALOSA MEDIOCRIS

< 0.5 ALOSA PSEUDOHARENGUS

< 0.5 ALOSA SAPIDISSIHA

< 0.5 AtlCHOA MITCHILLI 11.6 ANGUILLA ROSTRATA

< 0.5 BREVOORTIA TYRANNUS 12.9 CARANX HIPPOS

< 0.5 CYNOSCION REGALIS

< 0.5 CYPRINUS CARPIO

< 0.5 DOROSOHA CEPEDIANUM

< 0.5 DOROSOHA PETENalSE ELOPS SAURUS ETHEOSTOHA OLMSTED!*

FUNDULUS DIAPHANUS

< 0.5 FUtlDULUS HETEROCLITUS

.0.6 e

FUNOULUS LUCIAE FUNDULUS HAJALIS

< o.s GAr.BUSIA AFFINIS GOB!OSOMA BOSCI

< o.s HYBOGNATHUS NUCHALIS ICTALURUS CATUS ICTALURUS NEBULOSUS

< o.s ICTALURUS PUNCTATUS

< 0.5 LEIOSTOHUS XANTHURUS 6.6 LEPOMIS GIBBOSUS

< o.s LEPOHIS MACROCHIRUS HEMBRAS HARTINICA MENIDIA BERYLLINA 9.1 MENIDIA HEtlIOIA 38.8 MICROPOGOH UNOULATUS

< 0.5 MOP.ONE AMERICANA 2.8 MORONE SAXATILIS

< 0.5 MUGIL CEPHALUS MUGIL CUREHA NOTEHIGO}lUS CRYSOLEUCAS

< 0.5 NOTROPIS ANALOSTANUS NOTROPIS CORNUTUS NOTROPIS HUOSONIUS 5.9 PARALICHTHYS DENTATUS

< 0.5 PERCA FLAVESCENS POHATOHUS* SALTATRIX STRONGYLURA MARINA

< 0.5 SYHPHURUS PLAGIUSA TRINECTES HACULATUS

< 0.5 UMBRA PYGHAEA

< 0.5 POST_PCT 3.1

< 0.5

< 0.5

. 10.0

< 0.5 42.4

< 0.5 0.6

< 0.5

< o.s

< 0.5 2.3 2.0

< 0.5

< o.s

< o.s

< o.s

< 0.5

< 0.5 0.7 7.9

< o.s 0.5 14.8 6.7 1.4

< 0.5

< 0.5

< 0.5

< 0.5 0.7

< 0.5

< 0.5 3.3

< 0.5

< 0.5

< o.s

< 0.5

< o.s

< 0.5

_79_PCT

< 0.5 8.3 6.8

< 0.5 0.6

< 0.5 1.0 o.s

< 0.5 0.5 0.7 65.l

< 0.5

< 0.5 6.2 1.8 2.2 2.5 0.7

< o.s 2.2

< 0.5

< o.s

e

  • .Tab1e*4.13.B.3-1B COMPOSITION OF SAMPLES DURING PRE-OPERATION (PRE PCTl, POST-OPERATION PRIOR TO. 1979 (POST_PCTl, AND THE CURRENT-YEAR C_79_PCTl VALUES ARE EXPRESSED AS PERCENTAGES SEE TEXT FOR FURTHER EXPLANATION

GEAR-TRAWL--------------------------------------------

SPECIES PRE_PCT POST_PCT

_79.... PCT ALOSA AESTIVALIS 0.8

< 0.5 ALOSA MEOIOCRIS 0.6 ALOSA PSEUOOHARENGUS 2.9

< 0.5

< 0.5 ALOSA SAPIDISSIHA 1.7

< 0.5 ANCHOA MITCHILLI 3.5 7.0

< 0.5 ANGUILLA ROSTRATA 1.4 1.6 0.5 BREVOORTIA TYRANNUS 0.7 cnlOSCIOH REGALIS 2.2 l.l

< 0.5 CYPRINUS CARPIO

< 0.5 0.5

< 0.5 DOROSOMA CEPEOIAHUH

< 0.5 l.2

< 0.5 OOROSOHA PETENENSE 0.7 ENNEACANTHUS GLORIOSUS

< 0.5 EUCINOSTOHUS ARGENTEUS

< 0.5 GOBIOSOHA BOSCI

< 0.5 GOBIOSOHA GINSBURG!

< 0.5 ICTALURUS CATUS 2.7 5.0 2.3 ICTALURUS NEBULOSUS

< 0.5 ICTALURUS FUtlCTATUS 8.1 11.9 1.9 LEIOSTOMUS XANTHURUS 6.5 14.4 7.5 HICROPOGOH UNOULATUS 6.6 10.0 10.0 MORONE AMERICANA 5.1 3.9 2.5 HORONE SAXATILIS

< 0.5

< 0.5

< 0.5 NOTROPIS HUDSONIUS 1.0 0.9 PARALICHTHYS DEMTATUS

< 0.5 TRINECTES HACULATUS 56.2 39.3 74.S 1

e e

4.13.C 4.13.C.1 RISTROPH (LOW-LEVEL) SCREEN MONITORING PROGRAM METHODS This program consists of two duplicate S-minute samples taken on either Tuesday, Wednesday, or Thursday of each week.

Fishes are collected in the sampling pool adjacent to the wash-water flume of the low-level screens.

They are then identified, classed as to model size, weighed and determined to be living or dead.

Weekly estimates of living and dead fiihes impinged are then calculated.

Additional sampling rs ;equi red if the survival rate falls below 75% (see also 4.13.B) and must continue until survival again exceeds 75%.

TS.4.13.E also requires the determination of the species responsible for the low survival and an analysis of the biological significance of the incident.

'-- J The Technical Specifications also require that additional weekly seine and trawl samples be taken in the event of screen failure, weather permitting (described in 4.13.B.1.A).

4.13.C.2 RESULTS.

Weekly impingement estimates are presented as Tables 4.13.C-1 through 4.13.c-52.

No additional screen samples were required due to low survival.

As stated in 4.13.C.1, additional seine and trawl samples were required due to screen malfunction only for the week of February 18.

The results of this sample are shown in Table 4.13.B.2.B-2.

SURRY POWER STATION

~A LEVEL WEEKLY REPORT Table 4.13.C-l Ave. No. Circ. Pumps:

Temperature Min-Max:

Salinity Min-Max:

Week Of Dec. 31, 1978 Through Jan. 6~ 1979 Survival Percentage:

  • 7 pumps with 6 screens VIMS (mm) rnnF COMMON NAME SCIENTIFIC NAME MODAL SIZE 040 Channel catfish lctalurus punctatus 039 White catfish I eta l urus catus 116 Brown bullhead lctalurus nebulosus 108 Golden shiner Notemigonus crysoleucas 110 Spottai l shiner Notropis hudsonius 060 American eel Anguilla rest rat a 051 Gizzard shad Dorosoma cepedianum 140-199 275 Threadfin shad Dorosoma petenense 026 Alewife Alosa pseudoha ren gus 027 Blueback herrina Alosa aestival is 60-79 037 Atlantic menhaden Brevoortia tyrannus
  • 3 Bay anchovy Anchoa mi tch i 11 i t,. J 40-59 9

Tidewater silverside Menidia beryl 1 i na 60-79 ISO Atlantic silverside Menidia menidia 80-99 135 Pumokinseed Lepomis gibbosus 40-59 032 White perch Marone americana 60-79 033 Spot Leiostomus xanthurus 005 Atlantic croaker Mtcropogon undulatus 151 Hog choker Tri nectes maculatus te R - 9/75 TOTAL 7,'e 4.3 - 4.3 4.3 - 4.3 92 O/o operating ALIVE DEAD 2,016 0

34,272 2,016 0

1,008 3,024 0

25.200

'O 1,008 0

18,144 4,032 83,664 7,056

SURRY POWER STATION Table 4.13.C-2 I LEVEL WEEKLY REPORT Week Of Jan. 7 Through Jan. 13, 1979 VIMS rnni:

COMMON NAME SCIENTIFIC NAME 040 Channel catfish lctalurus ounctatus 039 White catfish lctalurus cat us 116 Brown bul ]head I eta l urus nebulosus 8

Ave. No. Circ. Pumps:

Temperature Min - Max: ___

4_._1 -

4

  • 7 Salinity Min-Max:

1.6 - 1. 7 Survival Percentage:

94 MODAL SIZE (mm)

ALI VE DEAD 200-299 1,008 0

80-99 5,040 0

40-59 2,016 0

108 Golden shiner Notemigonus crysoleucas 110 Spot ta i l shiner Notropi s hudsonius 060 American eel Anqu i 11 a ros t rat a 200-299 2,016 0

051 Gizzard shad Dorosoma ceoedianum 140-199 19,152 1,008 275 Threadfin shad Dorosoma petenense 026 Alewife Alosa pseudoha rengus 80-99 6,048 3,024 027 Blueback herrinq Alosa aest i va 1 is 60-79 254,016 20,160 O"i7 Atlantic menhaden Brevoortia tyrannus 100-119, 120-139.

2,016 0

Bay anchovy 1, _Anchoa mi tchi 11 i Tidewater silverside Menidia beryl 1 i na 80-99 1,008 0

150 Atlantic si lverside Menidia menidia 80-99 28,224 0

135 Pumpkinseed Lepomis qibbosus 032 White perch Marone americana 60-79 44,352 1.008 033 Spot Lei os tomus xanthurus 005 Atlantic croaker Micropogon undulatus 151 Hog choker Trinectes maculatus 80-99 1,008 0

R - 9/75 TOTAL 365,904 25,200

Ave. No. Circ. Pumps:

6 T

t M.

M 4.2 - 4.5 em per a ure

,n-ax: ----

Salinity Min-Max:

l.l - 1.1 SURRY POWER STATION

. e,J LEVEL WEEKLY REPORT Table 4. 13.C-3 Week Of Jan. 14 Through Jan. 20, 1979 Survival Percentage:

96 VIMS CO!)F COMMON NAME SCIENTIFIC NAME MODAL SIZE (mm)

ALIVE DEAD 040 Channel catfish lctalurus punctatus 039 White catfish 1.ctalurus catus 100-119 2,016 0

116 Brown bullhead lctalurus nebulosus 60-79 1,008 0

108 Golden shiner Notemigonus crysoleucas 110 Spot tai 1 shiner Notropis hudsonius 060 American eel Anoui 1 la ros t rat a 200-299 1,008 0

051 Gizzard shad Dorosoma ceoedianum 140-199 31,248 2,016 275 Threadfin shad Dorosoma petenense 026 Alewife Alosa pseudoha rengus 60-79 4.032 0

027 Blueback herrino Alosa aestival is 60-79 900,144 33,264 017 Atlantic menhaden Brevoortia tyrannus Bey1 anchovy Anchoa mitchilli 80-99 1,008 0

9 Tidewater silverside Menidia beryl Ii na 60-79 5,040 0

ISO Atlantic silverside Menidia menidia 80-99 6,048 2,016 135 Pumpkinseed Lepomis oibbosus 032 White perch Mo rone ame r i can a 60-79 126,000 5,040 033 Spot Leiostomus xanthurus 005 Atlantic croaker Micropogon undulatus 40-59 3,024 2,016 151 Hog choker Trinectes maculatus R - 9/75 TOTAL 1~080,576' 44,352

.... SURRY POWER STATION

-..,w LEVEL WEEKLY REPORT Table 4.13.C-4 Week Of Jan. 21 Through Jan. 27, 1979 VIMS rnnF COMMON NAME SCIENTIFIC NAME 040 Channel catfish lctalurus punctatus 039 White catfish lctalurus catus 116 Brown bu 11 head lctalurus nebulosus 108 Golden shiner Notemigonus crysoleucas 110 Spot ta i I shiner Not rep i.s hudsonius 060 American eel Anguilla rest rat a 051 Gizzard shad Dorosoma ceoedianum 275 Threadfin shad Dorosoma oetenense 026 Alewife Alosa pseudoharengus 027 Blueback herrino Alosa aest i va 1 is 037 At 1 antic menhaden B revoo rt i a ty ran nus

~:

Bay anchovy Anchoa mitchilli Tidewater silverside Menidia beryl] i na 150 Atlantic silverside Menidia menidia 135 Pumokinseed Leoomis gibbosus 032 White perch Merone americana 033 Spot Leiostomus xanthurus 005 Atlantic croaker Micropogon undulatus*

151 Hog choker Trinectes maculatus R - 9/75 Ave. No. Circ. Pumps:

7 Temperature Min-Max:

4.7 - 4.7 ---

Salinity Min - Max:

-~.4 - 1_._s __

Survival Percentage:

9_8_ o;0 MODAL SIZE (mm)

ALIVE DEAD 80-99 1,008 0

500+

2,016 0

1 L..n-lQQ 56,448 0

60-79 1,008 0

60-79 217,728 6,048 120-139 1.008 0

60-79 5,040 0

80-99 4,032 0

60-79 55,440 0

60-79 1,008 0

TOTAL 344,736 6,048 I

~SURRY POWER STATION

.a,W LEVEL WEEKLY REPORT Table 4, 13,C-5 Ave. No. Circ. Pumps:

Temperature Min - Max:

Salinity Min-Max:

Week Of Jan. 28 Through Febo 3, 1979 Survival Percentage:

VIMS

('.()I)!=

COMMON NAME SC I ENTI FI C NAME MODAL SIZE (mm) 040 Channel catfish I eta l u rus punctatus 039 Whi"te catfish lctalurus catus 100-119 116 Brown bullhead lctalurus nebulosus 60-79 108 Golden shiner Notemigonus crysoleucas 110 Spottai 1 shiner Notropis hudsonius 060 American eel Anquilla ros t rat a 051 Gizzard shad Dorosoma cepedianum 140-199 275 Threadfin shad Dorosoma petenense 026 Alewife Alosa pseudoha rengus 027 BI ueback herrinq Alosa aestival is 60-79 017 Atlantic menhaden Brevoortia tyrannus 120-139

~:

Bay anchovy Anchoa mitchilli Tidewater silverside Menidia beryl 1 i na 60-79 150 Atlantic si lverside Menidia menidia 100-119 135 Pumpkinseed Lepomis qibbosus 032 White perch Marone americana 60-79 033 Spot Leiostomus xanthurus 120-139 005 Atlantic croaker Micropogon undulatus 40:...59 151 Hog choker Trinectes maculatus 142 Yellow perch Perea flavescens 200-299 030 American shad Alosa sapidissima 120-139*

003 Summer flounder Paralichthys dentatus 140-199 R - 9/75 TOTAL 8

(~'-)

4o9 - 4.9 0.2 0.2 96 O/o ALIVE DEAD 15,120 0

1,008 0

64.512 1.008 497,952 10,080 1.008 0

4,032_,

0 I

0 1,.008.,

I

.. ~

186,480

?1

, t;Q 3,024 0

2,016 0

1,008 0

1,008 0

1,008 0

779,184 32,256

URRY POWER STATION LEVEL WEEKLY REPORT Table 4.13.C-6 Ave. No. Circ. Pumps:

Temperature Min-Max:

Salinity Min-Max:

Week Of Feb. 4 Th rough

.Feb. 10, 19 79 Survival Percentage:

VIMS (mm) rnoE COMMON NAME SCIENTIFIC NAME MODAL SIZE 040 Channel catfish lctalurus punctatus 039 White catfish I eta I urus catus 60-79, 80-99 116 Brown bu 11 head lctalurus nebulosus 108 Golden.shiner Notemigonus crysoleucas 110 Spottai I shiner Notropis hudsonius 060 American eel Anguilla ros t rat a 051 Gizzard shad Dorosoma ceoedianum 140-199 275 Threadfin shad Dorosoma petenense 026 Alewife

. Alosa pseudoharengus 027 Blueback herrinq Alosa aest i va 1 is 60-79 037 Atlantic menhaden Brevoortia tyrannus Bay anchovy Anchoa mitchilli Tidewater silverside Menidia beryl I ina 60-79 150 Atlantic silverside Menidia menidia 135 Pumokinseed Lepomis qjbbosus 032 White perch Marone americana 60-79 033 Spot Leiostomus xa.nthurus 005 Atlantic croaker Micropogon undulatus 151 Hog choker Trinectes maculatus R - 9/75 TOTAL 4

C~)

1.2 - 1.2 2.4 - 2.4 90 0/o AL I VE DEAD 5,040 0

4,032 0

8,064 3,024 1,008 0

.46.368 4.032 64,512 7,056

SURRY POWER STATION Table 4.13.c-7 Circ.

5

(~

Ave. No.

Pumps:

' LEVEL WEEKLY REPORT Temperature Min-Max:

0.0... o.o Salinity Min-Max:

3.2 3.3 Week Of Feb~ 11 Th rough Feb. i 7, 19 79 Survival Percentage:

79 O/o

  • 5 pumps with 3 screens operating VIMS (mm) rnoF COMMON NAME SCIENTIF[C NAME MODAL SIZE ALIVE DEAD 040 Channel catfish lctalurus punctatus 039 White catfish lctalurus catus 116 Brown bullhead lctalurus nebulosus 108 Golden shiner Notemigonus crysoleucas 110 Spot ta i 1 shiner Notropis hudsonius 060 American eel Anguilla ros t rat a 051 Gizzard shad Dorosoma cepedianum 275 Threadfin shad Dorosoma petenense 026 A 1 ewi fe Alosa pseudoharengus 027 B 1 ueback herring Alosa aestival is 60-79 6,048 1,008 037 Atlantic menhaden Brevoortia tyrannus C

Bay anchovy Anchoa mi tch i 11 i 20-39 0

1,008 Tidewater silverside Menidia beryl l i na 40-59,60-79 2,016 0

150 Atlantic silverside Menidia menidia 135 Pumokinseed Lepomis gibbosus 032 White perch Marone americana 60-79 2,016 1.008 033 Spot Leiostomus xanthurus 005 Atlantic croaker Micropogon undulatus 151 Hog choker Trinectes maculatus 052 Carp Cyprinus carpio 140-199 1.008 0

I I

R - 9/75 TOTAL 11,088 3,024

Table 4. 13.C-8 Week of February 18 through February 24, 1979 No samples are available due to screen malfunction.

The data collected in seine and trawl samples that are required in such circumstances are presented in Table 4.13.B.2.B-2.

During this week weather conditions were bad enough that it did not appear possible to conduct the required seine and trawl sampling.

Due to this possibility, a deviation report (Number 79-14) was filed on 2/21/79.

However, weather conditions did permit sampling on 2/23/79.

URRY POWER STATION LEVEL WEEKLY REPORT Table 4.13.C-9 Ave. No. Circ. Pumps:

Temperature Min-Max:

Salinity Min - Max:

4.*

  • 5.7 - 5.9 0.o - _o __._o __

Week Of Feb. 25 Through March 3, 1979 Survival Percentage:

100

  • 4 pumps with 3 screens operating VIMS (mm) r.nni:

COMMON NAME SCIENTIFIC NAME MODAL SIZE ALI VE DEAD 040 Channel catfish lctalurus punctatus 0-39 Whi.te catfish I eta 1 urus catus 116 Brown bu 11 head lctalurus nebulosus 108 Golden shiner Notemigonus crysoleucas 110 Spottai 1 shiner Notropis hudsonius 060 American eel Anquilla ros t rat a 051 Gizzard shad Dorosoma cepedianum 140-199 2,016 0

275 Threadfin shad Dorosoma petenense 026 Alewife Alosa pseudoha rengus 027 B 1 ueback herrinq Alosa aestival is 037 Atlantic menhaden Brevoortia tyrannus rl Bay anchovy Anchoa mitchilli Tidewater silverside flenidia beryl Ii na 150 Atlantic sllverside Menidia menidia 135 Pumpkinseed Lepomis gibbosus 032 White perch Marone americana 60-79 3,024 0

033 Spot Leiostomus. xanthurus 005 Atlantic croaker Micropogon undulatus 151 Hog choker Trinectes maculatus R - 9/75 TOTAL 5,040 0

Ave. No. Circ. Pumps:

Temperature Min-Max:

4

  • SURRY POWER STATION I! LEVEL WEEKLY REPORT Table 4. ]3.C-10 9.7 - 9.8 Salinity Min - Max:

0.0 - 0.1 Week Of March 4 Through March 10, 1979 Survival Percentage:

9..t..9-0/o

  • 4 numns with 3 screens oneratin£ VIMS rnni::

COMMON NAME SCIENTIFIC NAME MODAL SIZE (mm)

ALIVE DEAD 040 Channel catfish lctalurus punctatus 039 White c-atf i sh lctalurus catus 80-99 22,176 0

116 Brown bu 11 head lctalurus nebulosus 40-59 67, 536 0

108 Golden shiner Notemigonus crysoleucas 110 Spottail shiner -

Notropis hudsonius 060 American eel Anquilla ros t rat a 200-299 1,008 0

051 Gizzard shad Dorosoma cepedianum 140-199 1.008 0

275 Threadfin shad Dorosoma petenense 026 Alewife Alosa pseudoha rengus 027 B 1 ueback herrino Alosa aestival is 60-79 1,008 0

037 Atlantic menhaden Brevoortia tvrannus

~

Bay anchovy Anchoa mitchilli Tidewater silverside Menidia beryllina ISO Atlantic si 1.verside*

Menidia menidia 135 Pumokinseed Lepomis oibbosus 032 White perch Mo rone ame r i can a 140-199 22,176 1.008 033 Spot Leiostomus xanthi.Jrus 005 Atlantic croaker Micropogon undulatus 151 Hog choker Trinectes maculatus 031 Striped bass Marone saxatilis 140-199 1.008 0

142*

Yellow perch Perea flavescens 140-199 1,008 0

R - 9/75 TOTAL 116,928 1,008

SURRY POWER STATION

~W LEVEL WEEKLY REPORT Week Of 11arch 11 VIMS rnn~

COMMON NAME 040 Channel* catfish 039 White catfish 116 Brown bullhead Table 4. 13.C-ll Through March 17, 1979 SCIENTIFIC NAME lctalurus ounctatus lctalurus catus lctalurus nebulosus Ave. No. Circ. Pumps:

4

  • Temperature Min-Max: __ 1_0_._8_- 11.6 Salinity Min-Max:

0.0 -

OoO Survival Percentage:

96 %

  • 4 pumps with 3 screens operating MODAL SIZE (mm)
  • ALIVE DEAD 80-99 55,440 0

60-79. 100-119 2,016 0

108 Golden shiner Notemigonus crysoleucas 110 Spottail shiner Notrop is hudsonius 060 American eel Anquilla rest rat a 140-199, 400-499 2,016 0

051 Gizzard shad Dorosoma ceoedianum 140-199 7,056 1,008 275 Threadfin shad Dorosoma petenense 026 Alewife Alosa pseudoha rengus 027 Blueback herrinq Alosa aestival is 60-79 11,088 2,016 037 Atlantic menhaden Brevoortia* tyrannus Bay anchovy Anchoa mi tch i 11 i Tidewater silverside Menidia bery 11 i na 1.;o Atlantic silverside Menidia menidia 135 Pumpkinseed Lepomis qibbosus 032 White perch Merone americana 60-79 11.03,824 3,024 033 Spot Leiostomus xanthurus 005 Atlantic croaker Micropogon undulatus I

151 Hog choker Trinectes maculatus 80-99 5,040 2,016 100 Sea laI'lprey Petromyzon marinus 500 +

1,008 0

R - 9/75 TOTAL 187,488 8,064

~~URRY POWER STATION LEVEL WEEKLY REPORT Table 4. 13.c-12 Week Of March 18 Through Harch 24, 1979 VIMS rnriF COMMON NAME SCIENTIFIC NAME 040 Channel catfish lctalurus punctatus 039 White catfish lctalurus catus 116 Brown bullhead lctalurus nebulosus 108 Golden shiner Notemigonus crysoleucas 110 Spottai 1 shiner Notropis hudsonius 060 American eel Anguilla rest rat a 051 Gizzard shad Dorosoma ceoedianum 275 Threadfin shad Dorosoma petenense 026 Alewife Alosa pseudoharengus 027 Blueback herri nq Alosa aest i va 1 is 037 Atlantic menhaden Brevoortia tyrannus 3

Bay anchovy Anchoa mitchill i 149 Tidewater silverside Menidia beryl l ina 150 Atlantic silverside Menidia menidia 135 Pumokinseed Leoomis gibbosus 032 White perch Morone americana 033 Spot Leiostomus xanthurus 005 Atlantic croaker Micropogon undulatus 151 Hog choker Trinectes maculatus R - 9/75 Ave. No. Circ. Pumps:

4 Temperature Min-Max: __

l_l_._3 ___

l_l_._5_

Salinity Min - Max:

Survival Percentage:

MODAL SIZE (mm) 100-110 80-99 400-499 140-199 80-99 60-79 80-99 60-79 60-79, 140-199 60-79 TOTAL 0.2 - 0.2 94 AL I VE DEAD F, nli.R 0

6.048 0

1.008 0

1.008 0

1,008 0

6.048 2 016 1,008 2,016 1.008 0

37,296 0

1.008 0

61,488 4,032

URRY POWER STATION LEVEL WEEKLY REPORT Week Of MARCH 25 VIMS rnni:

COMMON NAME 040 Channel catfish 039 White catfish 116 Brown bu! !head Table 4. 13.c-13 Through MARCH 31, 1979 SCIENTIFIC NAME lctalurus punctatus lctalurus catus lctalurus nebulosus Ave. No. Circ. Pumps:

Temperature Min - Max:

Salinity Min - Max:

Survival Percentage:

4 *

11. 7 -
11. 8 0.1 - 0.1 9_2_ 0;0
  • 4 pumps with 3 screens operating MODAL SIZE (mm)

ALIVE DEAD 80-99 1,008 0

108 Golden shiner Notemigonus crysoleucas 110 Spottail shiner Notropis hudsonius 80-99 2,016 0

060 American eel Angu i 11 a ros t rat a 051 Gizzard shad Dorosoma ceoedianum 200-299 1,008 0

275 Threadfin shad Dorosoma petenense

  • 026 Alewife Alosa pseudoharengus 027 Blueback herrinq Alosa aestival is 60-79 2,016

, nnR 0~7 Atlantic menhaden Brevoortia tyrannus 200-299

J,.,008 0

~

Bay anchovy Anchoa mitchilli 80-99 4,032 2.016 Tidewater silverside Menidia beryl 1 i na 60-79

, om~

0

-l.50 Atlantic silverside Menidia menidia 135 Pumpkinseed Lepomis gibbosus 40-59, 60-79 2,016 0

032 White perch Marone americana 60-79 68,544 t... ()1?

033 Spot Leiostomus xanthurus 005 Atlantic croaker Micropogon undulatus 151 Hogchoker Trinectes maculatus 60-79 2,016 0

122 Mummichog Fundulus heteroclitus 80-99 1,008 0

089 Tessellated darter Etheostoma olmstedi 80-99 1,008 0

R - 9/75 TOTAL 86,688 7,056

URRY POWER STATION LEVEL WEEKLY REPORT Table 4. 13.C-14 Week Of APRIL 1 Th rough APRIL 7, 19 79 VIMS rnoF COMMON NAME SCIENTIFIC NAME 040 Channel catfish lctalurus punctatus 039 White catfish lctalurus catus 116 Brown bu 11 head lctalurus nebulosus 108 Golden shiner Notemigonus crysoleucas 110 Spottai l shiner Notropis hudsonius 060 American eel Anguilla ros t rata 051 Gizzard shad Dorosoma cepedianum 275 Threadfin shad Doroso~a petenense 026 Alewife Alosa pseudoha rengus 027 B 1 ueback herrinq Alosa aestival is 037 Atlantic menhaden Brevoortia tyrannus C

Bay anchovy Anchoa mitchill i Tidewater silverside Menidia beryl l i na 150 Atlantic silverside Menidia menidia 135 Pumokinseed Lepomis gibbosus 032 White perch Marone americana 033 Spot Leiostomus xanthurus 005 Atlantic croaker Micropogon undulatus 151 Hog choker Trinectes maculatus 142 Yellow perch Perea flavescens R - 9/75 Ave. No. Circ. Pumps:

4 Temperature Min-Max: _.;..__14_.l - 14

  • 2 Salinity Min-Max:

O.O - 0.1 Survival Percentage:

100 %

MODAL SIZE (mm)

ALI VE DEAD 100-119 4,032 0

80-99 3,024 0

200-299 1.008 n

140-199 1,008 0

80-99 1 nnR 0

60-79 6,048 0

80-99 1,008 0

60-79 25,200 0

80-99 11,088 0

120-139 1.1, 008 0

TOTAL 54,432 0

.a.suRRY POWER STATION

~W LEVEL WEEKLY REPORT Table 4. ]3.C-15 Week Of APRIL 8 Th rough APRIL 14, 19 79 VIMS rnni:-

COMMON NAME SCIENTIFIC NAME 040 Channel catfish lctalurus punctatus 039 White catfish lctalurus catus 116 Brown bu] !head lctalurus nebulosus 108 Golden shiner Notemigonus crysoleucas 110 Spottail shiner Notropis hudsonius 060 American eel Anquilla ros t rat a 051 Gizzard shad Dorosoma cepedianum 275 Threadfin shad Dorosoma petenense 026 Alewife Alosa pseudoha rengus 027 B 1 ueback herrinq Alosa aestival is 037 Atlantic menhaden Brevoortia tyrannus 3

Bay anchovy Anchoa mitchill i 149 Tidewater silverside Menidia beryl 1 ina 1.:;o Atlantic silverside Menidia menidia 135 Pumpkinseed Lepomis qibbosus 032 White perch Merone americana 033 Spot Leiostomus xanthurus 005 Atlantic croaker Micropogon undulatus 151 Hog choker Trinectes maculatus 089 Tessellated

(

darter' Etheostoma olmstedi R - 9/75 Ave. No. Circ. Pumps:

Temperature Min-Max:

Salinity Min - Max:

Survival Percentage:

MODAL SIZE (mm) 100-119 60-79 80-99 140-1gg 100-119 120-139, 140-199 80-99 60-79 80-99 80-99 TOTAL 4

14.3 - 14.3 1.2 - 1.2 97 ALIVE DEAD 22,176 0

3,024 0

1,008 0

10,080 0

1,008 0

2,016 0

3,024 1.008 58,464 2.016 4.032 n

1,008 0

105,840 3,024

-URRY POWER STAT I ON LEVEL WEEKLY REPORT Table 4.13.C-16 Week Of APRIL 15 Through APRIL 21, 1979 VIMS rnnE COMMON NAME SCIENTIFIC NAME 040 Channel catfish lctalurus punctatus 039 White catfish lctalurus cat us 116 Brown bu! !head lctalurus nebulosus 108 Gal den shiner Notemigonus crysoleucas 110 Spottai l shiner Notropis hudsonius 060 American eel Anguilla rest rat a 051 Gizzard shad Dorosoma cepedianum 275 Threadfin shad Dorosoma petenense 026 Alewife Alosa pseudoha rengus 027 Blueback herrinq Alosa aestival is 037 Atlantic menhaden Brevoortia tyrannus

~

Bay anchovy Anchoa mi tch i 11 i Tidewater silverside Menidia beryl Ii na 150 Atlantic silverside Menidia menidia 1'35 Pumokinseed Lepomis gibbosus 032 White perch Mo rone ame r i can a 033 Spot Leiostomus xanthurus 005 Atlantic croaker Micropogon undulatus 151 Hog choker Trinectes maculatus 136 Bluegill I

Lepomis macrochirus R - 9/75 Cl?)

Ave. No. Circ. Pumps:

3 Temperature Min-Max: 14.5 - 15. 3 Salinity Min - Max:

0.4 - 0.4 Survival Percentage:

__ 9_5 __ 0/0 MODAL SIZE (mm)

ALIVE DEAD 80-99 2,016 0

60-79 1,008 0

140-199, 400-499 2,016 0

100-119 1,008 0

40-59, 60-79 4,032 0

60-79 23,184 2.016 100-119 2,016 0

TOTAL 35,280 2,0J,.6

SURRY POWER STATION Table 4. 13.C-17 Ave. No. Circ. Pumps:

2 W LEVEL WEEKLY REPORT Temperature Min-Max:

17.6 - 18.0 Salinity Min - Max:

o

  • 9 - __ 1 __
  • ___ o"---_

Week Of APRIL 22, 1979 Through APRIL 28, 1979 Survival Percentage:

89 O/o VIMS rn n i:

COMMON NAME SCIENTIFIC NAME MODAL SIZE (mm)

ALIVE DEAD 040 Channel catfish I eta l urus punctatus 039 White catfish lctalurus catus 80-99, 120-139 2,016 0

116 Brown bul ]head I eta l urus nebulosus 108 Golden shiner Notemigonus crysoleucas 110 Spottai l shiner Notropis hudsonius 80-99 2,016 0

060 American eel Anguilla ros t rat a 051 Gizzard shad Do rosoma cepedianum 140-199 1,008 0

275 Threadfin shad Dorosoma petenense 026 Alewife Alosa pseudoha ren gus 80-99 1,008 0

027 B 1 ueback he rri nq Alosa aestival is 037 Atlantic menhaden Brevoortia tyrannus 140-199 1,008 0

-~

Bay anchovy Anchoa mi tch i 11 i 60-79

  • 80-99 4,032 0

Tidewater silverside Menidia beryl l i na I SO Atlantic silverside Menidia menidia 135 Purnokinseed Lepomis gibbosus 80-99 1,008 0

032 White perch Mo rone arne r i can a 60-79 45,360 7,056 033 Spot Leiostomus xanthurus 100-119 1,008 0

005 Atlantic croaker Micropogon undulatus 60-79 0

1.008 151 Hog choker Trinectes maculatus 60-79 5,040 n

R - 9/75 TOTAL 63,504 8,064

SURRY POWER STATION*

~

LEVEL WEEKLY REPORT Table 4. ]3.C-18 Ave. No. Circ. Pumps:

Temperature Min-Max:

Salinity Min-Max:

Week Of. APRIL 29 Through MAY 5, 1979 Survival Percentage:

VIMS rnn~

COMMON NAME SCIENTIFIC NAME MODAL SIZE (mm) 040 Channel catfish lctalurus punctatus 039 White catfish lctalurus catus 80-99 116 Brown bu 11 head lctalurus nebulosus 108 Golden shiner Notemi genus crysoleucas 110 Spottail shiner Notropis hudsonius 80-99 060 American eel Anguilla rest rat a 200-299 051 Gizzard shad Dorosoma ceoedianum 140-199 275 Threadfin shad Dorosoma petenense 026 Alewife Alosa pseudoharengus

\\

027 Blueback herrinq Alosa aestival is 037 Atlantic menhaden Brevoortia tyrannus Ii Bay anchovy Anchoa mi tch i 11 i 60-"79 Tidewater silverside Menidia beryl 1 i na ISO Atlantic silverside Menidia menidia 135 Pumokinseed Lepomis qibbosus 120-139 032 White perch Merone americana 80-99 033 Spot Leiostomus xanthurus 005 Atlantic croaker Micropogon undulatus 151 Hog choker Trinectes maculatus R - 9/75 TOTAL 2

(.,~)

18.3 18.5 0.6 - 0.6 100 O/o AL I VE DEAD 1,008 0

1,008 0

1.008 0

2,016 0

1,008 0

1,008 0

3.024 0

10,080 0

3*

(_-,6)

~~URRY POWER STATION Table 4.13.c-19 Ave. No. Circ. Pumps:

Temperature Min-Max:

21.4 - 21.4 LEVEL WEEKLY REPORT Salinity Min - Max:

1.0 -

1.1 Week Of May 6 Through May 12, 1979 Survival Percentage=

90 O/o VIMS CODF COMMON NAME SCIENTIFIC NAME MODAL SIZE (mm)

ALIVE DEAD 040 Channel catfish lctalurus punctatus 039 White catfish lctalurus catus 116 Brown bu 11 head lctalurus nebulosus 108 Golden shiner Notemigonus crysoleucas 110 Spottail shiner Notropis hudsonius 060 American eel Angu rl 1 a rest rat a 400-499 1.008 0

051 Gizzard shad Dorosoma cepedianum 275 Threadfin shad Dorosoma petenense 026 Alewife Alosa pseudoha rengus 027 B 1 ueback he rri no Alosa aestival is 037 Atlantic menhaden Brevoortia tyrannus 120-139 1.008 0

C Bay anchovy Anchoa mitchill i Tidewater silverside Menidia beryl Ii na 1 o;o Atlantic silverside Menidia menidia 135 Pumpkinseed Lepomis gibbosus 80-99,100-119 2.016 0

032 White perch Merone americana 60-79.80-99 1.oc,6 0

033 Spot Leiostomus xanthurus 40-59 6.048 0

005 Atlantic croaker Micropogon undulatus 151 Hogchoker Trin~ctes maculatus 60-79 1.008 0

148 Rough silverside Membras martinica 80-99 0

?.n1h R - 9/75 TOTAL 18,144 2,016

~SURRY POWER STATION

~W LEVEL WEEKLY REPORT Table 4.13.C-20 Ave. No. Circ. Pumps:

Temperature Min-Max:

Salinity Min - Max:

Week Of May 13 Through May 19, 1979 Survival Percentage:

VIMS cooi:

COMMON NAME SCIENTIFIC NAME MODAL SIZE (mm) 040 Channel catfish I eta 1 urus punctatus 039 White catfish lctalurus catus 116 Brown bullhead lctalurus nebulosus 100-119 108 Golden shiner Notemigonus crysoleucas 110 Spottai I shiner Notropis hudsonius 060 American eel Anquilla ros t rat a 051 Gizzard shad Dorosoma cepedianum 275 Threadfin shad Dorosoma petenense 026 Alewife Alosa pseudoha rengus 027 B 1 ueback herrinq Alosa aestival is 037 Atlantic menhaden Brevoortia tyrannus 3

Bay anchovy Anchoa mi tch i 11 i 80-99 149 Tidewater silverside Menidia beryl l i na ISO Atlantic silverside Menidia menidia 135 Pumpkinseed Lepomis qibbosus 100-119 032 White perch Mo rone ame r i can a 80-99 033 Spot Leiostomus xanthurus 40-59 005 Atlantic croaker Micropogon undulatus 151 Hogchoker Trinectes maculatus R - 9/75 TOTAL 3

18.3 - 18.5 1.0 -

1.0

_l_O_O __ 0;0 ALI VE DEAD 3,024 1,008 3,021.i 9,072 3,024 19,152 0

0 0

0 0

0

~SURRY POWER STATION W LEVEL WEEKLY REPORT Table 4. 13.C-21 Ave. No. Circ. Pumps:

Temperature Min-Max:

3 22.0 - 22.3 Salinity Min - Max:

0.9 1.0 Week Of May 20 Through May 26, 1979 Survival Percentage:

91 VIMS CODF COMMON NAME SC I ENT IF IC NAME MODAL SIZE (mm)

ALI VE DEAD 040 Channel catfish lctalurus punctatus 1.L.0-199 1.008 0

039 White catfish lctalurus catus 100-119,120-139 2,016 0

116 Brown bul !head lctalurus nebulosus 80-99 1.008 0

108 Golden shiner Notemigonus crysoleucas 110 Spottail shiner Notropis hudsonius 060 American eel Anguilla ros t rat a 051 Gizzard shad Dorosoma cepedianum 400-499 1,008 0

275 Threadfin shad Dorosoma petenense 026 Alewife Alosa pseudoharengus 027 B 1 ueback herring Alosa aestival is 037 Atlantic menhaden Brevoortia tvrannus 40-59 9,072 1.008 Bay anchovy Anchoa mitchilli 40-59 1,008 1.008 Tidewater silverside Menidia beryl] ina I SO Atlantic silverside Menidia menidia 135 Pumpkinseed Lepomis gibbosus 032 White perch Marone americana 60-79.80-99 12.096 1.008 033 Spot Leiostomus xanthurus 40-59 62,L.96 6,048 005 Atlantic croaker Micropogon undulatus 151 Hog choker Trinectes maculatus 40-59 2.016 0

031 Striped bass Merone saxatilis 140-199 1,008 0

R - 9/75 TOTAL 92,736 9,072

I SURRY POWER STATION Table 4. 13.C-22 W LEVEL WEEKLY REPORT Week Of May 27 Through June 2, 1979 VIMS rnnF COMMON NAME SCIENTIFIC NAME 040 Channel catfish lctalurus punctatus 039 White catfish lctalurus catus 116 Brown bu 11 head lctalurus nebulosus 108 Golden shiner Notemigonus crysoleucas 110 Spot ta i 1 shiner Notropis hud'son i us 060 American eel Anguilla ros t rat a 051 Gizzard shad Dorosoma cepedianum 275 Threadfin shad Dorosoma petenense 026 Alewife Alosa pseudoha rengus 027 Blueback herrino Alosa aestival is 037 Atlantic menhaden Brevoortia tyrannus

~

Bay anchovy Anchoa mitchilli Tidewater silverside Menidia beryl Ii na ISO Atlantic silverside Menidia menidia 135 Pumpkinseed Lepomis gibbosus 032 White perch Merone americana 033 Spot Leiostomus xanthurus 005 Atlantic *croaker Micropogon undulatus 151 Hog choker Trinectes maculatus R - 9/75 Ave. No. Circ. Pumps=

Temperature Min-Max:

Salinity Min - Max:

Survival Percentage=.

MODAL SIZE (mm) 100-119,120-139 40-59 60-79 iio-59 80-99 TOTAL 3

22.3 - 22.3 o.4 - o.4 85 AL I VE DEAD 2,016 0

1.008 1.008 1,008 0

26,208 5,040 3,024 0

33,264 6,048

~URRY POWER STATION Table 4. 13.C_ 23

~

LEVEL WEEKLY REPORT Ave. No. Circ. Pumps:

Temperature Min-Max:

Salinity Min - Max:

Week Of June 3 Through June 9, 1979 Survival Percentage:

VIMS rnni::

COMMON NAME SCIENTIFIC NAME MODAL SIZE (mm) 040 Channel catfish lctalurus ounctatus 039 White catfish lctalurus catus 100-119,140-199 116 Brown bullhead lctalurus nebulosus, 108 Golden shiner Notemigonus crysoleucas 110 Spottail shiner Notropis hudsonius 060 American eel Anquilla ros t rat a 051 Gizzard shad Dorosoma ceoedianum 275 Threadfin shad Dorosoma oetenense 026 Alewife Alosa pseudoharengus 027 B 1 ueback herrinq Alosa aestival is 037 Atlantic menhaden B revoo rt i a ty ran nus 40-59,60-79 I

60-79

~;

Bay anchovy Anchoa mi tch i 11 i Tidewater si lverside Menidia beryl Ii na 150 Atlantic si lve.rside Menidia menidia 135 Pumokinseed Leoomis qibbosus 032 White perch Morone americana 033 Spot Leiostomus xanthurus 40-59 005 Atlantic croaker Micropogon undulatus 80-99 151 Hog choker Trinectes maculatus 40-59 134 Warmouth Lepomis gulosus 140-199 This report may include the effects of a reported Irish kill in the lower James River which was first observed on June 14, 1979.

R - 9/75 TOTAL

(?~)

24.5 - 24.6 0.3 -

0.3 85*

ALIVE DEAD 2,016 0

2,016 5,040 0

1,008 64,512 7,056 2,016 0

2,016 0

1,008 0

73,584 13,104

URRY POWER STATION LEVEL WEEKLY REPORT Table 4.13.c-24 Ave. No. Circ. Pumps:

Temperature Min-Max:

Salinity Min - Max:

Week

  • Of June 10 Through June 16, 1979 Survival Percentage:

VIMS r"n F.

COMMON NAME SCIENTIFIC NAME MODAL SIZE (mm) 040 Channel catfish lctalurus punctatus 200-299 039 White catfish lctalurus cat us 80-99 116 Brown bul ]head lctalurus nebulosus 108 Golden shiner Notemigonus crysoleucas 120-139 110 Spottai l shiner Notropis hudsonius 80-99 060 American eel Anguilla ros t rat a 051 Gizzard shad Dorosoma cepedianum 275 Threadfin shad Dorosoma petenense 026 Alewife Alosa pseudoha ren gus 027 B 1 ueback herring Alosa aes ti va 1 is 0'37 Atlantic menhaden Brevoortia tyrannus 40-59 rl Bay anchovy Anchoa mitchilli Tidewater silverside Menidia beryl 1 i na I SO Atlantic silverside Menidia menidia 135 Pumpkinseed Lepomis gibbosus 032 White perch Merone americana 80-99,100-ll9 033 Spot Leiostomus xanthurus 40-59 005 Atlantic croaker Micropogon undulatus 151 Hog choker Trinectes maculatus This report may include the effects of a reported fish kill in the lower James River which was first observed on June 14, 1979.

e R - 9/75 TOTAL 3*

22.0 - 22.1 o.o -

o.o 84*

ALIVE DEAD 0

1.008 1,008 0

1,008 0

1,008 0

23,184 21.168 2,016 0

104,832 3,024 133,056 25,200

URRY POWER STATION Table 4. 13.C-25 Ave. No. Circ. Pumps:

LEVEL WEEKLY REPORT Temperature Min-Max:

Salinity Min - Max:

Week Of June 17 Through June 23, 1979 Surviv.al Percentage:

VIMS rnni=

COMMON NAME SCIENTIFIC NAME MODAL SIZE (mm) 040 Channel catfish lctalurus ounctatus 200-299 039 White catfish lctalurus catus 116 Brown bullhead I eta l urus nebu.losus 80-99 108 Golden shiner Notemigonus crysoleucas 110 Spottai l shiner Notropis hudsonius 060 American eel Anguilla ros t rat a 200-299,300-399 051 Gizzard shad Dorosoma ceoedianum 275 Threadfin shad Dorosoma petenense 026 Alewife Alosa pseudoharengus 027 Blueback he rri no Alosa aest i va 1 is 037 Atlantic menhaden Brevoortia tvrannus 40-59 1'9 Bay anchovy Anchoa mi tch i 11 i Tidewater silverside Menidia beryl l ina ISO Atlantic silverside Menidia menidia 135 Pumpkinseed Leoomis oibbosus 032 White perch Mo rone ame r i can a 100-119 033 Spot Leiostomus xanthurus 40-59 005 Atlantic croaker Micropogon undulatus 151 Hog choker Trinectes maculatus 40-59

~

R - 9/75 TOTAL of.)

3 21.3 - 21. 7 o.8 -

0.9 96 ALI VE DEAD 1,008 0

1,008 0

2,016 0

3,024 1,008*

6.0L.8 0

54,432 2.016 1.008 0

68,544 3,024

~SURRY POWER STATION

  • w LEVEL WEEKLY REPORT Table 4.13.C-26 Week Of June 2Li.

Through June 30, 1979 VIMS r.nni:

COMMON NAME SCIENTIFIC NAME 040 Channel catfish lctalurus punctatus 039 White catfish lctalurus catus 116 Brown bul ]head lctalurus nebulosus 108 Golden shiner Notemigonus crysoleucas 110 Spot tai 1 shiner Notropis hudsonius 060 American.eel Anquilla ros t rat a 051 Gizzard shad Dorosoma cepedianum 275 Threadfin shad Dorosoma petenense 026 Alewife Alosa pseudoha rengus 027 Blueback herring Alosa aestival is 037 Atlantic menhaden Brevoortia tyrannus Bay anchovy Anchoa mitchilli Tidewater silverside Menidia beryl Ii na

]SO Atlantic silverside Menidia menidia 135 Pumpkinseed Lepomis qibbosus 032 White perch Marone ameri cana 033 Spot Leiostomus xanthurus 005 Atlantic croaker Micropogon undulatus 151 Hog choker Trinectes maculatus R - 9/75 Ave. No. Circ. Pumps:

Temperature Min-Max:

Salinity Min - Max:

Survival Percentage:

MODAL SIZE (mm) 200-299 80-99 40-59 I

~

TOTAL 2

24.7 - 25.1 1.3 -

1.4 91 ALIVE DEAD 1,008 0

4,032 0

25y200 1.008 30,240 1,008

Ave. No. Circ. Pumps:

Temperature Min-Max:

SURRY POWER STATION Table 4. 13.C-27 e.l LEVEL WEEKLY REPORT Salinity Min - Max:

  • Week Of July l Through July 1, 1979 Survival Percentage:

VIMS rnoF COMMON NAME SCIENTIFIC NAME MODAL SIZE (mm) 040 Channel catfish lctalurus punctatus 039 White catfish lctalurus catus 116 Brown bullhead lctalurus nebulosus 120-139 108 Golden shiner Notemigonus crysoleucas 110 Spottail shiner Notropis hudsonius 060 American eel Anguilla rest rata 051 Gizzard shad Dorosoma ceoedianum 275 Threadfin shad Dorosoma petenense 026 Alewife Alosa pseudoha ren gus 027 B 1 ueback herrinq Alosa aestival is 037 Atlantic menhaden Brevoortia tyrannus 40-59 C

Bay anchovy Anchoa mitchilli Tidewater silverside Menidia beryl 1 i na ISO Atlantic silverside Menidia me*n id i a 135 Pumokinseed Lepomis gibbosus 032 White perch Merone americana 033 Spot Leiostomus xanthurus 60-79 005 Atlantic croaker Micropogon undulatus 60-79 I

151 Hog choker Trinectes maculatus R - 9/75 TOTAL 2

22.9 - 23.1 3.6 -

3.7

__ 9_0 __ 0;0 ALIVE DEAD 1,008 0

10,080 1.008 6,048 1.008 1,008 0

18,144 2,016

SURRY POWER STATION I* LEVEL WEEKLY REPORT Week Of July 8 VIMS rnnF COMMON NAME 040 Channel catfish 039 White catfish 116 Brown bullhead Table 4.13.C-28 Ave. No. Circ. Pumps:

Temperature Min-Max:

Salinity Min - Max:

Through July 14., 1979 Survival Percentaoe:

SCIENTIFIC NAME MODAL SIZE (mm) lctalurus punctatus I eta 1 urus catus lctalurus nebulas us 108 Golden shiner Notemigonus crysoleucas 110 Spottai 1 shiner Notropis hudsonius 060 American eel Anguilla rest rat a 051 Gizzard shad Dorosoma cepedianum 275 Threadfin shad Dorosoma petenense 026 Alewife Alosa pseudoharengus 027 Blueback herring Alosa aestival is 037 Atlantic menhaden Brevoortia tvrannus rl Bay anchovy Anchoa mitchilli 60-79 Tidewater silverside Menidia beryl Ii na I SO Atlantic silverside Menidia menidia 135 Pumpkinseed Lepomis qibbosus 032 White perch Merone americana 033 Spot Leiostomus xanthurus 60-79 005 Atlantic croaker Micropogon undulatus 151 Hog choker Tri nectes maculatus 19 R - 9/75 TOTAL 2

26.1 -

5.3 ----

100 01


,o ALIVE DEAD 1.,008 1.,008 2.,016 0

0 0

URRY POWER STATION LEVEL WEEKLY REPORT Week Of July 15 VIMS COMMON NAME rnoi:

040 Channel.catfish 039 White catfish 116 Brown bullhead Table 4. 13.c-29 Ave. No. Circ. Pumps:

Temperature Min-Max:

Salinity Min-. Max:

Through July 21,1979 Survival Percentage:

SCIENTIFIC NAME MODAL SIZE (mm) lctalurus punctatus I eta 1 urus* cat us lctalurus nebulosus 108 Golden shiner Notemigonus crysoleucas 110 Spottail shiner Notrop is hudsonius 060 American eel Anguilla ros t rat a 051 Gizzard shad Dorosoma ceoedianum 275 Threadfin shad Dorosoma petenense 026 Alewife Alosa pseudoharengus 027 B 1 ueback he rri nq Alosa aestivalis 037 At 1 antic menhaden Brevoortia tyrannus

-I Bay anchovy Anchoa mi tch i 11 i Tidewater silverside Menidia beryl 1 i na 150 Atlantic silverside Menidia menidia 135 Pumok i nseed

  • Lepomis qibbosus 032 White perch Marone americana 033 Spot Leiostomus xanthurus 100-119 005 Atlantic croaker Micropogon undulatus 60-79 151 Hog choker Trinectes maculatus 80-99

~

R - 9/75 TOTAL 2

29.5 - 30.1 5.6 -

5.7 100 0/

/0 ALIVE DEAD 1,008 5,040 1,008 7,056 0

O*

0 0

SURRY POWER STATION Ii' LEVEL WEEKLY REPORT Table 4. 13.c-30 Ave. No. Circ. Pumps:

Temperature Min-Max:

Salinity Min - Max:

Week Of July 22 Through Jul7 28, 1979

  • Survival Percenta~e:

VIMS COMMON NAME SCIENTIFIC NAME MODAL SIZE (mm) rnnF 040 Channel catfish lctalurus punctatus 039 White catfish lctalurus catus 116 Brown bullhead lctalurus nebulosus 120-139,140-199 108 Golden shiner Notemigonus crysoleucas 110 Spot tail shiner Notropis hudsonius 060 American eel Anquilla rostrata 140-199 051 Gizzard shad Dorosoma cepedianum 275 Threadfin shad Dorosoma petenense 026 Alewife Alosa pseudoharengus 027 Bl t.ieback herring Alosa aestival is 037 Atlantic menhaden Brevoortia tyrannus 60-79 103 Bay anchovy Anchoa mi tch i 11 i

[JI Tidewater silverside Menidia beryl l i na I SO Atlantic silverside Menidia menidia 135 Pumpkinseed Lepomis qibbosus 032 White perch Marone americana 40-59,80-99 033 Spot Leiostomus xanthurus 80-99 005 Atlantic croaker Micropogon undulatus 80-99 151

  • Hog choker Trinectes maculatus

[a R - 9/75 TOTAL 2

lrJ) 27.1 - 27.4 4.1 -

4.1 84 ALIVE DEAD 2.016 0

1,008 0

1,008 1,008" 2,016 0

3,024 1,008 1,008

. 0.

10.,080 0

SURRY POWER STATION LEVEL WEEKLY REPORT Week Of July 29 VIMS Table 4.13.C-31

~hrough Aug 4, 1979 r.nni::

COMMON NAME SCIENTIFIC NAME 040 Channel catfish lctalurus punctatus 039 White catfish lctalurus catus 116 Brown bullhead lctalurus nebulosus Ave. No. Circ. Pumps=

Temperature Min-Max:

Salinity Min - Max:

Survival Percentatle:

MODAL SIZE (mm) 100-119 120-139 108 Golden shiner Notemigonus crysoleucas 110 Spottail shiner Notropis hudsonius 060 American eel Anquilla res trata 051 Gizzard shad Dorosoma ceoedianum

'275 Threadfin shad Dorosoma petenense 026 Alewife Alosa pseudoharengus 027 Blueback herrinci Alosa aestivalis 037 Atlantic menhaden Brevoortia tyrannus 40-59 Bay anchovy Anchoa mitchilli 60-79 Tidewater silverside Menidia beryl Ii na l SO Atlantic silverside Menidia menidia 135 Pumpkinseed Lepomi s q i"bbosus 032 White perch Marone americana 033 Spot Leiostomus xanthurus 60-79 005 Atlantic croaker Hicropogon undulatus 80-99 151 Hog choker Trinectes maculatus 007 Weakfish Cynoscion regalis 40-59 11 R - 9/75 TOTAL (h) 2 28.3 - 28.4 4.5 -. 4.6 9_3 __ o/o ALIVE DEAD 1,008 4,032 1,008 0

0 0

3,024 1,008 1,008 0

1.008 O*

1.008 0

12,096

. 1,008

SURRY POWER STATION

~* LEVEL WEEKLY REPORT Week Of August 5 VIMS r.nni; COMMON NAME 040 Channel catfish 039 White catfish 116 Brown bu! lhead Table 4. 13.c-32 Ave. No. Circ. Pumps:

Temperature Min-Max:

Salinity Min - Max:

Through August 11, 1979 Survival Percentage:

SCI ENTI Fl C NAME MODAL SIZE (mm) lctalurus punctatus lctalurus catus 140-199 lctalurus nebulosus 100-119,120-139 108 Golden shiner Notemigonus crysoleucas 110 Spottai I shiner Notropis hudsonius 060 American eel Angui 11 a rostrata 051 Gizzard shad Dorosoma cepedianum 275 Threadfin shad Dorosoma petenense 026 Alewife Alosa pseudoharengus 027 Blueback he rri no Alosa aestivalis 037 Atlantic menhaden Brevoortia tyrannus 103 Bay anchovy Anchoa mi tch i 11 i Tidewater silverside Menidia beryl 1 i na I SO Atlantic silverside Menidia menidia 135 Pumokinseed Lepomis gibbosus 032 White perch Morone americana 80-99,120-139 033 Spot Leiostomus xanthurus 80-99 005 Atlantic croaker Micropogon undulatus 80-99 151 Hogchoker Trinectes maculatus R - 9/75 TOTAL 28.7 - 28.8 6.4 -

6.h

_1_0_0 __ 0/0 ALIVE DEAD 1,008 2,016 2.016 1,008 J.024 9,072 0

0 0

0 O*

0

SURRY POWER STATION

~I LEVEL WEEKLY REPORT Week Of August 12 VIMS r11ni; COMMON NAME 040 Channel catfish 039 White catfish I 16 Brown bu 1 I head Table '4. 13.c-33 Ave. No. Circ. Pumps:

Temperature Min-Max:

Salinity Min - Max:

Through August 18, 1979 Survival Percenta9e:

SCIENTIFIC NAME MODAL SIZE (mm) lctalurus punctatus lctalurus catus lctalurus nebulosus 108 Golden shiner Notemigonus crysoleucas I 10 Spottai 1 shiner Notropis hudsonius 060 American eel Anguilla ros t rat a 051 Gizzard shad Dorosoma cepedianum 275 Threadfin shad Dorosoma petenense 026 Alewife Alosa pseudoharengus 027 BI ueback herring Alosa aest i va Ii s 037 Atlantic menhaden Brevoortia tyrannus 80-99 103 Bay anchovy Anchoa mitchilli Tidewater silverside Menidia beryl 1 i na ISO Atlantic silverside Menidia menidia 135 Pumpkinseed Lepomis gibbosus 032 White perch Merone americana 033 Spot Leiostomus xanthurus 100-119 005 Atlantic croaker Micropogon undulatus 151 Hog choker Trinectes maculatus R - 9/75 TOTAL 2

24.2 - 24.2 5.8 -

5.9

_l_O_O __ 0/0 ALIVE DEAD 2~016 5,040 7,056 0

0 0

~URRY POWER STATION

... LEVEL WEEKLY REPORT Table 4.l3.c-34 Ave. No. Circ. Pumps:

Temperature Min - Max:

Salinity Min - Max:

Week Of August 19 Through August 25, 1979 Survival Percenta~e=

VIMS rnnF" COMMON NAME SCIENTIFIC NAME MODAL SIZE (mm) 040 Channel catfish lctalurus punctatus 039 White catfish lctalurus catus 116 Brown bu 11 head lctalurus nebulosus 108 Golden shiner Notemigonus crysoleucas 110 Spottail shiner Notropis hudsonius 060 American eel Anquilla ros trata 051 Gizzard shad Dorosoma cepedianum 275 Threadfin shad Dorosoma petenense 026 Alewife Alosa pseudoharengus 027 B 1 ueback herrinq Alosa aestival is 037 Atlantic menhaden Brevoortia tyrannus 103 Bay anchovy Anchoa mi tch i 11 i Tidewater silverside Menidia beryl Ii na ISO Atlantic silverside Menidia menidia 135 Pumpkinseed Lepomis qibbosus 032 White perch Marone americana 033 Spot Leiostomus Xc!nthurus 60-79 005 Atlantic croaker Micropogon undulatus 151 Hog choker Trinectes maculatus

[ti R - 9/75 TOTAL 2

24.2 - 24.2 6.4 - 6.5 100 ALIVE DEAD 8,064 8,064 0

0

SURRY POWER STATION

,, LEVEL WEEKLY REPORT Week Of August 26 VlMS rnni:-

COMMON NAME 040 Channel catfish 039 White catfish 116 Brown bu 11 head Table 4. ]3.C-35 Ave. No. Circ. Pumps:

Temperature Min-Max:

Salinity Min - Max:

Through September 1, 1979 Survival Percenta~e:

SCIENTIFIC NAME MODAL SIZE (mm) lctalurus punctatus lctalurus catus lctalurus nebulosus 108 Golden shiner Notemigonus crysoleucas 110 Spottai 1 shiner Not rop is hudsonius 060 American eel Anouilla rostrata 051 Gizzard shad Dorosoma ceoedianum 275 Threadfin shad Dorosoma petenense 026 Alewife Alosa pseudoharengus 027 BI ueback herrinq Alosa aest i va Ii s 017 Atlantic menhaden Brevoortia tyrannus Ii

  • Bay anchovy Anchoa mitchilli Tidewater silverside Menidia beryl Ii na 1 '10 Atlantic silverside Menidia menidia 135 Pumokinseed Leoomis qibbosus 032 White perch Merone americana 033 Spot Leiostomus x~nthurus 60-79 005 Atlantic croaker Micropogon undulatus 120-139 151 Hog choker Trinectes maculatus

,e R - 9/75 TOTAL 2

27.2 - 27.3 6.1 -

6.1

_l_O_O __ 0/0 ALIVE DEAD 1,008 1,008 2,016 0

O*

0

SURRY POWER STATION Ave. No. Circ. Pumps:

/ LEVEL WEEKLY REPORT Table 4. 13.c-36 Temperature Min-Max:

Salinity Min - Max:

Week Of Sept. 2 Through Sept. 8, 1979 Survival Percentage=

VIMS COMMON NAME rnni=

SCIENTIFIC NAME MODAL SIZE (mm) 040 Channel catfish lctalurus punctatus 039 White catfish lctalurus catus 120-139 116 Brown bullhead lctalurus nebulosus 100-119 108 Golden shiner Notemigonus crysoleucas 110 Spottail shiner Notropis hudsonius 060 American eel Anguilla ros t rat a 051 Gizzard shad Dorosoma cepedianum 275 Threadfin shad Dorosoma petenense 026 Alewife Alosa pseudoharengus 027 B 1 ueback herring Alosa aestivalis 037 Atlantic menhaden Brevoortia tyrannus 80-99 11 Bay anchovy Anchoa mitchilli Tidewater silverside Menidia beryl l i na l SO Atlantic silverside Menidia menidia 135 Pumpkinseed Lepomis gibbosus 032 White perch Merone americana 140-199 033 Spot Leiostomus xanthurus 60-79 005 Atlantic croaker Micropogon undulatus 80-99 151 Hog choker Trinectes maculatus 40-59 122 Munnnichog Fundulus heteroclitus 60-79 031 Striped bass Merone saxatilis 60-79 R - 9/75 TOTAL 2

26.7 - 26.8 6.1 -

6.2

_...,.,9=0 __ 0/o ALIVE DEAD 1.008 0

1,008 0

,
  • 040 1.008 3.024 0

12,096 2,016 1,008 0

1,008 0

1.008 0

2.016 0

27,216 3,024

SURRY POWER STATION 9' LEVEL WEEKLY REPORT Week Of Sept. 9 VIMS rnni=

COMMON NAME 040 Channel catfish 039 White catfish 116 Brown bul I head Table 4.13.C-37 Ave. No. Circ. Pumps:

Temperature Min-Max:

Salinity Min - Max:

Through Sept. 15, 1979 Survival Percentage:

SCIENTIFIC NAME MODAL SIZE (mm) lctalurus punctatus lctalurus catus 140-199 lctalurus nebulosus 140-199 108 Golden shiner Notemigonus crysoleucas 110 Spottai I shiner Not rop is hudsonius 060 American eel Anquilla rost rat a 051 Gizzard shad Dorosoma cepedianum 275 Threadfin shad Dorosoma petenense 026 Alewife Alos~ pseudohare~gus 027 B 1 ueback herrinq Alosa aestivalis 037 Atlantic menhaden B revoo rt i a ty rann us 80-99 103 Bay anchovy Anchoa mitchilli ra Tidewater silverside Menidia beryl I ina I SO Atlantic silverside Menidia menidia 135 Pumpkinseed Lepomis qibbosus 032 White perch Morone americana 033 Spot Leiostomus xanthurus 80-99 005 Atlantic croaker Micropogon undulatus 100-119 151 Hogchoker Trinectes maculatus 122 Mummichog Fundulus heteroclitus 60-79

[II R - 9/75 TOTAL C ~ r}

2 23.6 - 23.9 o.5 - o.5

_.,._9""'1 __ o/o ALIVE DEAD 2.016 0

1.008 0

13.104 2.016 21.216 3.024 7.056 0

1,008 0

51.,408

  • 5,040

SURRY POWER STATION e* LEVEL WEEKLY REPORT Week Of Sept. 16 VIMS rnn~

COMMON NAME 040 Channel catfish 039 White catfish 116 Brown bu 11 head Table 4. 13.c-38 Ave. No. Circ. Pumps:

Temperature Min-Max:

Salinity Min - Max:

Th rough Sept. 22, 1979 Survival Percentac;ie=

SCIENTIFIC NAME MODAL SIZE (mm) lctalurus punctatus lctalurus catus lctalurus nebulosus 108 Golden shiner Notemigonus crysoleucas 110 Spottai 1 shiner Not rop is hudsonius 060 American eel Anguilla ros trata 051 Gizzard shad Dorosoma ceoedianum 275 Threadfin shad Dorosoma petenense 026 Alewife Alosa pseudoharengus 027 B 1 ueback herrinq Alosa aestival is 017 Atlantic menhaden Brevoortia tyrannus 80-99 103 Bay anchovy Anchoa mitchilli 60-79 Tidewater silverside Menidia beryl I ina 150 Atlantic silverside Menidia meni di a 135 Pumpkinseed Lepomis gibbosus 032 White perch Marone americana 80-99,lh0-199 033 Spot Leiostomus xanthurus 100-119 005 Atlantic croaker Micropogon undulatus 151 Hog choker Trinectes maculatus 80-99 031 Striped bass Marone saxatilis 40-59 R - 9/75 TOTAL 2

23.1 - 23.1 1.0 -

1.0 89 ALIVE DEAD 6.048 2.016 1.008 0

13.104 0

2.016 1,008 1,008 0

1,008 0

24,192

  • 3,024

.URRY POWER STATION LEVEL WEEKLY REPORT Week Of Sept.- 23 VIMS c:nni=

COMMON NAME 040 Channel catfish 039 White catfish 116 Brown bullhead Table 4.13.c-39 Ave. No. Circ. Pumps:

Temperature Min-Max:

Salinity Min - Max:

Through Sept. 29, 1979 Survival Percenta;e:

SCIENTIFIC NAME MODAL SIZE (mm) lctalurus punctatus 200-299 lctalurus catus 140-199 lctalurus nebulosus 140-199 108 Golden shiner Notemigonus crysoleucas 110 Spottai I shiner Not rop is hudsonius 060 American eel Anquilla rost rata 300-399 051 Gizzard shad Dorosoma cepedianum 200-299 275 Threadfin shad Dorosoma petenense 026 Alewife Alosa pseudoharengus 027 BI ueback he rri nq Alosa aestivalis 037 Atlantic menhaden Brevoortia tyrannus 60-79 Bay anchovy Anchoa mi tch i 11 i Tidewater silverside Menidia beryllina I SO Atlantic silverside Menidia menidia 135 Pumpkinseed Lepomis qibbosus 032 White perch Mo rone ame r i can a 100-119 033 Spot Leiostomus x"'nthurus 80-99 005 Atlantic croaker Micropogon undulatus 100-119 151 Hog choker Trinectes maculatus 60-79 122 Mummichog Fundulus heteroclitus 40-59,60-79 R - 9/75 TOTAL 2

19.2 - 19.2 0 *.3 -

0.3

_... 9.. 8 __ 0/o ALIVE DEAD 1.008 0

1,008 0

J.,024 0

1J008 0

1,008 0

51.408 4.032 4,032 0

180,/..i.32 1.008 1,008

o.

1,008 0

2,016 0

246,960

  • 5,040

Tab l e 4. l 3. C-40 Ave. No. Circ. Pumps:

Temperature Min-Max:

SURRY POWER STATION

' LEVEL WEEKLY REPORT Salinity Min - Max:

Week Of_Sept. 30, 1979 Through Oct. 6, 1979 Survival Percenta~e:

VIMS rnni:::

COMMON NAME SCIENTIFIC NAME MODAL SIZE (mm) 040 Channel catfish lctalurus punctatus 300-399 039 White catfish lctalurus.catus 100-119,140-199 116 Brown bullhead lctalurus nebulosus 140-199 108 Golden shiner Notemigonus crysoleucas 110 Spottail shiner Notropis hudsonius 060 American eel Anguilla rost rata 051 Gizzard shad Dorosoma cepedianum 275 Threadfin shad Dorosoma petenense 026 Alewife Alosa pseudoharengus 027 B 1 ueback herrinq Alosa aestival is 017 Atlantic menhaden Brevoortia tyrannus Bay anchovy Anchoa mi tch i*t 1 i Tidewater silverside Menidia beryllina 150 Atlantic silverside Menidia menidia 135 Pumpkinseed Lepomis qibbosus 032 White perch Marone americana 140-199 033 Spot Leiostomus xanthurus 80-99 005 Atlantic croaker Micropogon undulatus 100-119 151 Hog choker Trinectes maculatus 100-119 122 Mummichog Fundulus heteroclitus 60-79 te R - 9/75 TOTAL 2

22.0 - 22.1 o.o -

o.o 100 ALIVE DEAD 1,008 2.016 3,024 1.t008 8,06h 3,024 5.040 1,008 24,192 0

0 0

0 0

0 0

0 0

SURRY POWER STATION 9' LEVEL WEEKLY REPORT Table 4.13.C-41 Ave. No. Circ. Pumps:

Temperature Min-Max:

Salinity Min - Max:

Week Of Oct. 7, 1979 Through Oct. 13, 1979 Survival Percentage:

VIMS rnni=

COMMON NAME SCIENTIFIC NAME MODAL SIZE (mm) 040 Channel catfish lctalurus punctatus 039 White catfish.

lctalurus catus 120-139 116 Brown bullhead lctalurus nebulosus 140-199 108 Go 1 den sh i ne r Notemigonus crysoleucas 110 Spottai I shiner Notropis hudsonius 80-99 060 American eel Anguilla rostrata 200-299 051 Gizzard shad Dorosoma cepedianum 60-79.200-299 275 Threadfin shad Dorosoma petenense 026 Alewife Alosa pseudoharengus 80-99 027 Blueback he rri no Alosa aestivalis 60-79 037 Atlantic menhaden B revoo rt i a ty ran nus 60-79 103 Bay anchovy Anchoa mitchilli

a Tidewater silverside Menidia beryl Ii na 150 At I ai, t i c s i 1 ve rs i de Menidia meni di a 135 Pumokinseed Lepomis gibbosus 032 White perch Marone americana 60-79
  • 033 Spot Leiostomus Xc!nthurus 80-99 005 Atlantic croaker Micropogon undulatus 100-119 151 Hog choker Trinectes maculatus

[JI R - 9/75 TOTAL 2*

16.2 - 16.3 o.o -

0.1 98 ALIVE DEAD 3,024 3,024 8,064 1,008 2.016 1,008 1,008 7.056 0

0 0

0 0

0 0

0 187,488 5.040 65,520 0

6.048 O*

\\

285,264

  • 5,040

SURRY POWER STATION I LEVEL WEEKLY REPORT Table 4. 13.C-42 Ave. No. Circ.. Pumps:

Temperature Min-Max:

Salinity Min - Max:

Week Of Oct. 14 Through Oct. 201 1979 Survival Percentaoe:

VIMS r.nnF COMMON NAME SCIENTIFIC NAME MODAL SIZE (mm) 040 Channel catfish lctalurus punctatus 039 White catfish lctalurus catus 116 Brown bullhead lctalurus nebulosus 108 Golden shiner Notemigonus crysoleucas 110 Spottai 1 shiner Notropi s hudsonius 80-99 060 American eel Anguilla rost rat a 140-199 051 Gizzard shad Dorosoma cepedianum 80-99 275 Threadfin shad Dorosoma petenense 026 Alewife Alosa pseudoharengus 027 B 1 ueback herrinq Alosa aestivalis 037 Atlantic menhaden Brevoortia tvrannus 60-79 103 Bay anchovy Anchoa mitchilli

[II Tidewater silverside Menidia beryl I ina 1,;o Atlantic silverside Menidia menidia 135 Pumokinseed Lepomis gibbosus 032 White perch Merone americana 033 Spot Leiostomus xanthurus 60-79 005 Atlantic croaker Micropogon undulatus 151 Hog choker Trinectes maculatus R - 9/75 TOTAL l

14.2 - 14.2 o.o - o.o 100 o,

10 ALIVE DEAD 2.016 1.008 1,008 1,008 2.016 7,056 0

0 0

0 0

0

SURRY POWER STATION e* LEVEL WEEKLY REPORT Table 4. 13.C-43 Ave. No. Circ. Pumps:

Temperature ~in-Max:

Salinity Min - Max:

Week Of October 21,1979 Through. October 27, 1979 Survival Percentaoe=

VIM::i r:nni; COMMON NAME SCIENTIFIC NAME MODAL SIZE (mm) 040 Channel catfish lctaluru~ punctatus 039 White catfish lctalurus catus 140 - 199 116 Brown bu 11 head lctalurus nebulosus 100 - 119 108 Golden shiner Notemigonus crysoleucas 110 Spottai l shiner Notropis hudsonius 060 American eel Anguilla rostrata 200 - 299 051 Gizzard shad Dorosoma ceoedianum 275 Threadfin shad Dorosoma petenense 026 Alewife Alosa pseudoharengus 027 Blueback herrinq Alosa aestival is 017 Atlantic menhaden Brevoortia tyrannus 100 - 119 ii Bay anchovy Anchoa mitchilli Tidewater silverside Menidia beryllina 150 Atlantic silverside Menidia menidia 135 Pumpkinseed Lepomis gibbosus 032 White perch

.Marone americana 60 - 79 033 Spot Leiostomus xanthurus 80 - 99 005 Atlantic croaker Micropogon undulatus 100 - 119 151 Hog choker Trinectes maculatus 122 Mwnmichog Fundulus heteroclitus 40 - 59 011 Striped bass Merone saxatilis 60 - 79 R - 9/75 TOTAL 2

17,3 -

0.5 -

('f~)

17,3 0.5

_.....,.9._8 __ O/o.

ALIVE DEAD 4,032 0

2,016 0

1,008 0

2,016 1,008 lli.112 0

15,120 0

3,024 0

1,008 0

1,008 0

43,344 i,008

SURRY POWER STATION e* LEVEL WEEKLY REPORT Table 4.13.C-44 Ave. No. Circ. Pumps=

Temperature Min-Max:

Salinity Min - Max:

Week Of October 28., 1979 Through November 3., 1979 Survival Percentaoe=

VIM::i rnni; COMMON NAME SCIENTIFIC NAME MODAL SIZE (mm) 040 Channel catfish lctalurus punctatus 039 White catfish lctalurus catus 120 - 139 116 Brown bu I lhead lctalurus nebulosus 120 - 139 108 Golden shiner Notemigonus crysoleucas 110 Spottai 1 shiner Notropis hudsonius 060 American eel Anguilla ros t rat a 200 - 299 051 Gizzard shad Dorosoma ceoedianum 80 - 99

  • 140 - 19' 275 Threadfin shad Dorosoma petenense 026 Alewife Alosa pseudoharengus 027 B 1 ueback herrinq Alosa aestivalis 017 Atlantic menhaden Brevoortia tyrannus 80-99 103 Bay anchovy Anchoa mitchilli Tidewater silverside Menidia beryl Ii na 150 Atlantic silverside Menidia menidia 135 Pumokinseed Lepomis gibbosus 120 - 139 032 White perch Marone americana 60 - 79 I 80 - 99 033 Spot Leiostomus x~nthurus 80 - 99
  • 100 - 19<

005 Atlantic croaker Micropogon undulatus 151 Hog choker Trinectes maculatus

]I R - 9/75 TOTAL 3

15.9. - 16.5 1.4 -

1.6 100 ALIVE DEAD 4,032 0

1,008 0

1,008 0

2.016 0

2.016 0

1.008 0

6.,048 0

2.016 0

19,152 0

  • SURRY POWER STATION I' LEVEL WEEKLY REPORT.

Table 4.13.C-45 Week Of November 4, 1979 Through November 10~ 1979 VIMS rnni::

COMMON NAME SCIENTIFIC NAME

-040 Channel catfish lctalurus punctatus 039 White catfish lctalurus catus 116 Brown bul I head lctalurus nebulosus Ave. No. Circ. Pumps:

Temperature Min-Max:

Salinity Min - Max:

Survival Percentage:

MODAL SIZE (mm) 140 - 199 108 Golden shiner Notemigonus crysoleucas 110 Spottai l shiner Notropis hudsonius 060 American eel Anguilla rostrata 200 - 299 051 Gizzard shad Dorosoma cepedianum 275 Threadfin shad Dorosoma petenense 026 Alewife Alosa pseudoharengus 027 Blueback herrinq Alosa aestivalis 037 Atlantic menhaden Brevoortia tyrannus 103 Bay anchovy Anchoa mitchilli 60 - 79 Tidewater silverside Menidia beryl l ina 150 Atlantic.silverside Menidia menidia 135 Pumokinseed Lepomis gibbosus 120 - 139 032 White perch Merone americana 60 - 79 033 Spot Leiostomus xanthurus 100 - 119 005 Atlantic croaker Micropogon undulatus 151 Hog choker Trinectes maculatus 80 - 99 R - 9/75 TOTAL 4

14.7 - lh.7 1.1 -

1.1 100 ALIVE DEAD 1.008 0

1.008 0

1.008 0

1.008 0

3,018.

0 2,016 0

2,016 0

11,066 0

SURRY POWER STATION e* LEVEL WEEKLY REPORT Table 4.13.C-46 Week Of November 11, 1~79 Through November 17, 1979 VIMS rnni::

COMMON NAME SCIENTIFIC NAME 040 Channel catfish lctalurus punctatus 039 White catfish lctalurus catus 116 Brown bul I head lctalurus nebulosus Ave. No. Circ. Pumps:

Temperature Min-Max:

Salinity Min - Max:

Survival Percenta~e:

MODAL SIZE (mm) 140 - 199 108 Golden shiner Notemigonus crysoleucas 110 Spottai I shiner Notropis hudsonius 060 American eel Anguilla ros trata 051 Gizzard shad Dorosoma ceoedianum 80 - 99. 100 - 119 275 Threadfin shad Dorosoma petenense 026 Alewife Alosa pseudoharengus 027 BI ueback herrinq Alosa aestival is 037 Atlantic menhaden Brevoortia tyrannus ri Bay anchovy Anchoa mi tch i 11 i 60 - 79 Tidewater silverside Menidia beryl 1 ina 150 Atlantic silverside Menidia menidia 135 Pumokinseed Lepomis gibbosus 032 White perch Merone americana 100 - 119 033 Spot Leiostomus xanthurus 005 Atlantic croaker Micropogon undulatus 151 Hog choker Trinectes maculatus 100 - 119 R - 9/75 TOTAL L.

12.1 -

12.2

o. 7 0.9 100 ALIVE DEAD 1.008 0

2.016 0

1,008 0

1,008 0

3,02L.

0 8,064 0

llll~URRY POWER STATION LEVEL WEEKLY REPORT Table 4. ]3.C-47

  • *Week Of Nov. 18 Through Nov. 24, 1979 VIMS rnoi:

COMMON NAME SCIENTIFIC NAME 040 Channel catfish lctalurus punctatus 039 White catfish lctalurus catus 116 Brown bu 11 head lctalurus nebulosus 108 Golden shiner Notemigonus crysoleucas 110 Spot ta i 1 shiner Not rop is hudsonius 060 American eel Anquilla ros t rat a 051 Gizzard shad Dorosoma ceoedianum 275 Threadfin shad Dorosoma petenense 026 Alewife Alosa pseudoha rengus 027 B 1 ueback herrinq Alosa aestival is 017 Atlantic menhaden Brevoortia tyrannus I;

Bay anchovy Anchoa mitchilli Tidewater silverside Menidia beryl 1 i na 150 Atlantic silverside Menidia menidia 135 Pumokinseed Leoomis qibbosus 032 White perch Merone americana 033 Spot Leiostomus xanthurus 005 Atlantic croaker Micropogon undulatus 151 Hog choker Trinectes maculatus 136 Bluegill Lepomis macrochirus 031 Striped bass Morone saxatilis R - 9/75 Ave. No. Circ. Pumps:

Temperature Min-Max:

Salinity Min - Max:

Survival Percentage:

MODAL SIZE (mm) 100-119 300-399 100-119 80-99,100-119 120-139 80-99

/

TOTAL 4

12.8 - 12.9

_ o.6 -

o.6

_l_OO __ o;0

('it)

ALIVE DEAD 1,008 0

1,008 0

1,008 0

4,032 0

1,008 0

1,008 0

9,072 0

-~-~~------~--------,-------------------------

~SURRY POWER STATION W LEVEL WEEKLY REPORT Table 4.13.C-48 Week Of Nov. 25 Through Dec. 1, 1979 VIMS rnnF COMMON NAME SCIENTIFIC NAME 040 Channel catfish lctalurus punctatus 039 White catfish lctalurus catus 116 Brown bullhead lctalurus nebulosus 108 Golden shiner Notemigonus crysoleucas 110 Spot ta i 1 shiner Notropis hudsonius 060 American eel Anguilla ros t rat a 051 Gizzard shad Dorosoma cepedianum 275 Threadfin shad Dorosoma petenense 026 Alewife Alosa pseudoharengus 027 B 1 ueback herring Alosa aestival is 037 Atlantic menhaden Brevoortia tyrannus

~:

Bay anchovy Anchoa mitchilli Tidewater silverside Menidia beryl !'i na ISO Atlantic si1verside Menidia menidia 135 Pumokinseed Lepomis gibbosus 032 White perch Mo rone ame r i can a 033 Spot Leiostomus xanthurus 005 Atlantic croaker Micropogon undulatus 151 Hog choker Trinectes maculatus R - 9/75 Ave. No. Circ. Pumps:

Temperature Min-Max:

Salinity Min - Max:

Survival Percentage:

MODAL SIZE (mm) 40-59 100-119 60-79,80-99 40-59 TOTAL 3

12.6 - 12.8 0.3 -

0.3

_l_OO __ 0;0 AL I VE DEAD 1,008 l_ 0 4,032 0

2,016 0

1,008 0

8,064 0

URRY POWER STATION LEVEL WEEKLY REPORT Table 4.13.C-49 Week Of Dec. 2 Through Dec. 8, 1979 VIMS CODF COMMON NAME SCIENTIFIC NAME 040 Channel catfish I ctal urus punctatus 039 White catfish lctalurus catus 116 Brown bul !head lctalurus nebulosus 108 Golden shiner Notemigonus crysoleucas 110 Spottai 1 shiner Notropis hudsonius 060 Arne ri can eel Anguilla ros t rat a 051 Gizzard shad Dorosoma cepedianum 275 Threadfin shad Dorosoma petenense 026 Alewi-fe Alosa pseudoha rengus 027 Blueback herrino Alosa aest i va 1 is 037 Atlantic menhaden Brevoortia tyrannus

-I Bay anchovy Anchoa mi tch i 11 i Tidewater silverside Menidia beryl l i na l SO Atlantic silverside Menidia menidia 135 Pumokinseed Lepomis gibbosus 032 White perch Morone americana 033 Spot Leiostomus xanthurus 005 Atlantic croaker Micropogon undulatus 151 Hog choker Trinectes maculatus R - 9/75 Ave. No. Circ. Pumps:

4 Temperature Min-Max:

7.0 - 1.2 Salinity Min - Max:

o.h - o.h Survival Percentage=

96 MODAL SIZE (mm)

ALIVE DEAD 120-139 13.lOh 0

60-79 3.024 1.008 l,. J 60-79 1,008 0

60-79 26,208 0

80-99 3~021.i 0

40-.59 0

1.008 TOTAL 46,)68 2,016

SURRY POWER STATION e, LEVEL WEEKLY REPORT Week Of Dec. 9 VIMS r.nDF COMMON NAME 040 Channel catfish 039 White catfish 116 Brown bu 11 head Table L1. l3.C-50 Ave. No. Circ. Pumps:

Temperature Min - Max:

  • Salinity Min - Max:

Through Dec. 1.5; 1979

  • Survival Percentage:

SCIENTIFIC NAME MODAL SIZE (mm) lctalurus punctatus I eta 1 urus cat us lctalurus nebulosus 108 Golden shiner Notemigonus crysoleucas 110 Spot ta i 1 shiner Notropis hudsonius 060 American eel Anguilla rest rat a 051 Gizzard shad Dorosoma cepedianum 100-119 275 Threadfin shad Dorosoma petenense 026 Alewife Alosa pseudoha ren gus 027 B 1 ueback herrinq Alosa aest i va 1 is 60-79,100-119 037 Atlantic menhaden Brevoortia tyrannus 100-119 Bay anchovy Anchoa mitchilli Tidewater silverside Menidia beryl 1 i na 150 Atlantic silverside Menidia menidia 135 Pumokinseed Lepomis gibbosus 100-119 032 White perch Merone americana 80-99.140-199 033 Spot Leiostomus xanthurus 005 Atlantic croaker Micropogon undulatus 151 Hog choker Trinectes maculatus R - 9/75 TOTAL

~.......... -... -..... -**- --

4 9.1 - 10.3 o.u - o.4

-=l..;;.0..;;.0 __ 0/ 0 ALI VE DEAD 9.072 2,016 1,008 1§008 2.016 15,120 0

0 0

0 0

0

URRY POWER STATION LEVEL WEEKLY REPORT Week Of Deco 16 VIMS r.nni::

COMMON NAME 040 Channel catfish 039 White catfish 116 Brown bu 11.head Table 4.13.c-51 Ave. No. Circ. Pumps:

Temperature Min-Max:

Salinity Min - Max:

Through Dec. 22, 1979 Survival, Percentage:

SCIENTIFIC NAME MODAL SIZE (mm) lctalurus punctatus 1uo-199 lctalurus catus I eta l urus nebulosus 108 Golden shiner Notemigonus crysoleucas 110 Spottai I shiner Notropis hudsonius 060 American eel Anquilla ros t rat a 051 Gizzard shad Dorosoma ceoedianum 275 Threadfin shad Dorosoma petenense 026 Alewife Alosa pseudoha rengus 027 B 1 ueback herrinq Alosa aestival is 037 Atlantic menhaden Brevoortia tyrannus C

Bay anchovy

  • -. J Anchoa mitchilli Tidewater silverside Menidia beryl l ina 150 Atlantic silverside Menidia menidia 135 Pumpkinseed Lepomis qibbosus 032 White perch Merone americana 80-99 033 Spot Leiostomus xanthurus 005 Atlantic croaker Micropogon undulatus 151 Hog choker Trinectes maculatus 100-119 231 Striped.mullet Mugil cephalus 200-299

/

R - 9/75 TOTAL 3

5.2 - 5.3 4.l - 4.l

_l_O_O __ 0/0 ALIVE DEAD 1~008 0

12.096 0

2.016 0

l.008 0

16,128 0

URRY POWER STATION LEVEL WEEKLY REPORT Week Of Dec. 23 VIMS COMMON NAME C:ODF 040 Channel catfish 039 White catfish 116 Brown bu 11 head Table 4. 13.C-52 Ave. No. Circ. Pumps:

Temperature Min-Max:

Salinity Min - Max:

Through Dec. 29, 1979 Survival Percentage:

SCIENTIFIC NAME MODAL SIZE (mm) lctalurus punctatus I eta l urus catus I eta 1 urus nebulas us 108 Golden shiner Notemigonus crysoleucas 110 Spottai 1 shiner Notropis hudsonius 060 American eel Anquilla rest rat a 051 Gizzard shad Dorosoma cepedianum 275 Threadfin shad Dorosoma petenense 026 Alewife Alosa pseudoha rengus 027 Blueback herrinq Alosa aest i va 1 is 60-79 017 Atlantic menhaden Brevoortia tyrannus 80-99 tt Bay anchovy Anchoa mitchill i Tidewater silverside Menidia beryl l i na 150 Atlantic silverside Menidia menidia 135 Pumpkinseed Lepomis qibbosus 100-119 032 White perch Mo rone ame r i can a 60-79 033 Spot Leiostomus xanthurus 005 Atlantic croaker Micropogon undulatus 151 Hog choker Tri nectes maculatus 80-99 R - 9/75 TOTAL (co!i) 3 6.3 - 6.6 4.3 - 4.4 94 ALI VE DEAD 5,040 0

1,008 0

1.008 0

22.176 2,016 2,016 0

31,248 2,016