ATTACHMENT TO LICENSE AMENDMENT NO. 128 TO FACILITY COMBINED LICENSE NO. NPF-91 DOCKET NO.52-025 Replace the following pages of the Facility Combined License No. NPF-91 with the attached revised pages. The revised pages are identified by amendment number and contain marginal lines indicating the areas of change.
Facility Combined License No. NPF-91 REMOVE INSERT 7
7 Appendix C to Facility Combined License No. NPF-91 REMOVE INSERT C-412a C-412a C-414 C-414 C-416 C-416 C-419 C-419
(7) Reporting Requirements (a)
Within 30 days of a change to the initial test program described in UFSAR Section 14, Initial Test Program, made in accordance with 10 CFR 50.59 or in accordance with 10 CFR Part 52, Appendix D,Section VIII, Processes for Changes and Departures, SNC shall report the change to the Director of NRO, or the Directors designee, in accordance with 10 CFR 50.59(d).
(b)
SNC shall report any violation of a requirement in Section 2.D.(3),
Section 2.D.(4), Section 2.D.(5), and Section 2.D.(6) of this license within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. Initial notification shall be made to the NRC Operations Center in accordance with 10 CFR 50.72, with written follow up in accordance with 10 CFR 50.73.
(8) Incorporation The Technical Specifications, Environmental Protection Plan, and ITAAC in Appendices A, B, and C, respectively of this license, as revised including Amendment No. 128, are hereby incorporated into this license.
(9) Technical Specifications The technical specifications in Appendix A to this license become effective upon a Commission finding that the acceptance criteria in this license (ITAAC) are met in accordance with 10 CFR 52.103(g).
(10) Operational Program Implementation SNC shall implement the programs or portions of programs identified below, on or before the date SNC achieves the following milestones:
(a)
Environmental Qualification Program implemented before initial fuel load; (b)
Reactor Vessel Material Surveillance Program implemented before initial criticality; (c)
Preservice Testing Program implemented before initial fuel load; (d)
Containment Leakage Rate Testing Program implemented before initial fuel load; (e)
- 1.
The fire protection measures in accordance with Regulatory Guide (RG) 1.189 for designated storage building areas (including adjacent fire areas that could affect the storage area) implemented before initial receipt 7
Amendment No. 128
C-412a Amendment No. 128
- 1.
The column lines and floor elevations are identified and included on Figures 3.3-1 through 3.3-13.
- 2.
These wall (and floor) thicknesses have a construction tolerance of +/- 1 inch, except as noted and for exterior walls below grade where the tolerance is +12 inches, - 1 inch. These tolerances are not applicable to the nuclear island basemat.
- 3.
For walls that are part of structural modules, the concrete thickness also includes the steel face plates. Where faceplates with a nominal thickness of 0.5 inches are used in the construction of the wall modules, the wall thicknesses in this column apply. Where faceplates thicker than the nominal 0.5 inches are used in the construction of the structural wall modules, the wall thicknesses in the area of the thicker faceplates are greater than indicated in this column by the amount of faceplate thickness increase over the nominal 0.5 inches. Overlay plates are not considered part of the faceplates, and thus are not considered in the wall thicknesses identified in this column.
- 4.
For floors with steel surface plates, the concrete thickness also includes the plate thickness.
- 5.
Where a wall (or a floor) has openings, the concrete thickness does not apply at the opening.
- 6.
The elevation ranges for the shield building items are rounded to the nearest inch.
- 7.
The Wall or Section Description, Column Line information, and Floor Elevation or Elevation Ranges are provided as reference points to define the general location. The concrete thickness of an item intersecting other walls, roofs or floors at a designated location (e.g., column line) is not intended to be measured to the stated column line, but only to the point where the intersection occurs.
- 8.
Where applicable, the upper wall portions extend to their associated roofs, which may vary in elevation, e.g., sloped roofs.
- 9.
From one wall/floor section to another, the concrete thickness transitions from one thickness to another, consistent with the configurations in Figures 3.3-1 through 3.3-14.
- 10. This wall thickness has a tolerance of 1-5/8 inch.
- 11. This wall thickness has a tolerance of +4 inches, -1 inch above grade.
- 12. The concrete thickness is the total floor thickness, including the metal decking, where applicable.
- 13. The concrete in the kitchen and restroom areas is 2 inches thinner.
- 14. The 6-foot concrete thickness includes the thickness of the containment vessel bottom head in a local area at the center of containment.
C-414 Amendment No. 128 Table 3.3-1 (cont.)
Definition of Wall Thicknesses for Nuclear Island Buildings, Turbine Building, and Annex Building(1)
Wall or Section Description Column Lines(7)
Floor Elevation or Elevation Range(7)(8)
Concrete Thickness(2)(3)(4)(5)(9)
Applicable Radiation Shielding Wall (Yes/No)
Conical Roof Not Applicable From 271'-6" to 293'-9" 3'-0" (including 1/2 inch thick min.
steel plate liner on bottom face, outside of PCS tank exterior wall)
Yes PCS Tank External Cylindrical Wall Not Applicable From 293'-9" to 328'-9" 2'-0" Yes PCS Tank Internal Cylindrical Wall Not Applicable From 309'-4" to 329'-0" 1'-6" Yes PCS Tank Roof Not Applicable 328'-9" (Lowest) 329'-0" (Highest) 1'-3" No Nuclear Island Basemat Below shield building From 60'-6" to containment vessel or 82'-6" 6'-0" (14) to 22'-0" (varies)
No Auxiliary Building Walls/Floors Radiologically Controlled Column Line 1 wall From I to N From 66'-6" to 100'-0" 3'-0" No Column Line 1 wall From I to 5'-7" west of K-2 From 100'-0" to 109'-3" 2'-3" Yes Column Line 1 wall From 5'-7" west of K-2 to N From 100'-0" to 109'-3" 3'-0" Yes Column Line 1 wall From I to 5'-6" east of L-2 From 109'-3" to 180'-0" 2'-3" Yes Column Line 1 wall From 5'-6" east of L-2 to N From 109'-3" to 125'-0" 3'-0" Yes Column Line 1 wall From 5'-6" east of L-2 to N From 125'-0" to 180'-0" 2'-3" Yes Column Line 2 wall From I to K-2 From 66'-6" to 135'-3" 2'-6" Yes Column Line 2 wall From K-2 to L-2 From 66'-6" to 135'-3" 5'-0" Yes Column Line 2 wall From L-2 to N From 82'-6" to 135'-3" 2'-6" Yes Column Line 2 wall From I to J-1 From 135'-3" to 153'-0" 2'-0" Yes Column Line 3 wall From J-1 to J-2 From 66'-6" to 82'-6" 2'-6" Yes Column Line 3 wall From J-1 to J-2 From 100'-0" to 135'-3" 2'-6" Yes Column Line 3 wall From J-2 to K-2 From 66'-6" to 135'-3" 2'-6" Yes Column Line 3 wall From K-2 to L-2 From 66'-6" to 92'-8 1/2" 2'-6" Yes Column Line 4 wall From I to J-1 From 66'-6" to 135'-3" 2'-6" Yes Column Line 4 wall From J-1 to J-2 From 66'-6" to 92'-6" 2'-6" Yes Column Line 4 wall From J-1 to J-2 From 107'-2" to 135'-3" 2'-6" Yes Column Line 4 wall From J-2 to K-2 From 66'-6" to 135'-3" 2'-6" Yes Column Line 4 wall From I to intersection with shield building wall From 135'-3" to 180'-0" 2'-0" Yes
C-416 Amendment No. 128 Table 3.3-1 (cont.)
Definition of Wall Thicknesses for Nuclear Island Buildings, Turbine Building, and Annex Building(1)
Wall or Section Description Column Lines(7)
Floor Elevation or Elevation Range(7)(8)
Concrete Thickness(2)(3)(4)(5)(9)
Applicable Radiation Shielding Wall (Yes/No)
Column Line N wall From 1 to 4 (or to shield building)
From 135'-3" to 180'-0" 2'-0" Yes Labyrinth Wall between Col. Line 3 and 4 and J-1 to 5'-2" from J-2 Not Applicable From 82'-6" to 92'-6" 2'-6" Yes N-S Shield Wall (low wall) 5'-7" west of column line K-2 extending 16'-0" from column line 1 north From 100'-0" to 110'-0" 2'-6" Yes N-S Shield Wall 2'-9" east of column line L-2 extending 12'-9" from column line 1 north From 100'-0" to 109'-3" 3'-0" Yes N-S Shield Wall 2'-9" east of column line L-2 extending 12'-9" from column line 1 north From 109'-3" to 125'-0" 2'-9" Yes E-W Shield Wall 10'-0" north of column line 1 extending 13'-3" from column line N east From 100'-0" to 125'-0" 2'-9" Yes Auxiliary Area Basemat From 1-7.3 and I-N, excluding shield building From 60'-6" to 66'-6" 6'-0" No loor From 1 to 2 and I to N 82'-6" 2'-0" Yes Floor From 2 to 4 and J-1 to J-2 82'-6" 2'-0" Yes Floor From 4 north to the shield building ending 17'-4" south of column line 5 and J-1 to J-2 82'-6" 0'-9" Yes Pipe Chase Floor From 2 north to the shield building ending 17'-4" south of column line 5 and J-1 to J-2 92'-6" 2'-0" Yes Floor From 2 to 3 and J-2 to K-2 90'-3" 3'-0" Yes Floor From 3 to 4 and J-2 to K-2 92'-6" 2'-0" Yes Floor From 4 to 7.3 and I to J-1 82'-6" 2'-0" Yes Floor From 1 to 2 and I to N 100'-0" 3'-0" Yes Floor From 2 to 4 and K-2 to L-2 92'-8 1/2" 3'-2 1/2" Yes Floor From I to J-2 and 4 to shield building and vertical wall 17'-0" south of column line 5 107'-2" 2'-0" Yes Floor From I to shield building wall and from intersecting vertical wall before column line 5 to column line 5 105'-0" 0'-9" Yes Floor From column line 1 to 10'-0" north of column line 1 and from 2'-9" east of column line L-2 to N 125'-0" 3'-0" Yes
C-419 Amendment No. 128 Table 3.3-1 (cont.)
Definition of Wall Thicknesses for Nuclear Island Buildings, Turbine Building, and Annex Building(1)
Wall or Section Description Column Lines(7)
Floor Elevation or Elevation Range(7)(8)
Concrete Thickness(2)(3)(4)(5)(9)
Applicable Radiation Shielding Wall (Yes/No)
Corridor Wall between G and H From 9 to 13 From 117'-6" to 135'-3" 1'-6" Yes Column Line 9 wall From E to H From 117'-6" to 158'-0" 2'-0" Yes Floor From 2 to 4 and E to H 135'-3" 0'-8" Yes Floor From 4 to 4.1 and E to H 135'-3" 1'-0" (12)
Yes Floor From 9 to 13 and E to I.1 117'-6" 0'-8" (12)(13)
Yes Floor From 9 to 13 and E to I.1 135'-3" 0'-8" (12)
Yes Containment Filtration Rms A and B (North Wall)
Between column line E to H From 135'-3" to 158'-0" 1'-0" Yes Containment Filtration Rms A and B (East wall)
Between column line E to F From 135'-3" to 158'-0" 1'-0" Yes Containment Filtration Rm A (Floor)
Between column line E to H 135'-3" 1'-0" (12)
Yes Containment Filtration Rm B (Floor)
Between column line E to H 150'-3" 0'-8" (12)
Yes Turbine Building Wall adjacent to Column Line I.2 From Col. Line 11.05 to 11.2 From 100'-0" to 169'-0" 3'-0" No Wall along Column Line 11.2 From near I.2 to near Col. Line R From 100'-0" to 169'-0" 2'-0" No Wall adjacent to Column Line R From Col. Line 11.2 to Col. Line 11.05 From 100'-0" to 169'-0" 3'-0" No Wall along Column Line 11.02 From near Col. Line R to near Col.
Line Q From 100'-0" to 169'-0" 2'-0" No Wall along Column Line 11.05 From Col. Line K.4 to near Col. Line I.2 From 100'-0" to 169'-0" 2'-0" No