RESOLUTION OF COMMENTS BY THE OFFICE OF NUCLEAR REACTOR REGULATION ON DRAFT SAFETY EVALUATION FOR TOPICAL REPORT ANP-10337P, REVISION 0, PWR FUEL ASSEMBLY STRUCTURAL RESPONSE TO EXTERNALLY APPLIED DYNAMIC EXCITATIONS FRAMATOME, INC.
PROJECT NO. 99902041 This attachment provides the U.S. Nuclear Regulatory Commission (NRC) staffs review and disposition of the comments made by Framatome Inc. (formerly AREVA Inc.) on the draft safety evaluation for Topical Report ANP-10337P, Revision 0, PWR Fuel Assembly Structural Response to Externally Applied Dynamic Excitations.
Page Line Proposed Change/Comment NRC Response 5 5 Delete the words [''''''''''''''''' ''''] The NRC staff agrees with suggested editorial changes. The Final SE modified accordingly.
6 11, 12 Delete highlighted proprietary The NRC staff agrees with brackets, information is not suggested editorial changes. The proprietary Final SE modified accordingly.
6 38 Delete the words ['''''''''''''''' '''] The NRC staff agrees with suggested editorial changes. The Final SE modified accordingly.
7 23, 25 Delete highlighted proprietary The NRC staff agrees with brackets, information is not suggested editorial changes. The proprietary Final SE modified accordingly.
8 45 BAW-10133P should be BAW- The NRC staff agrees with 10133P-A suggested editorial changes. The Final SE modified accordingly.
10 1 ['''''''''''''''''''''''''' ] should be [''''''''' The NRC staff agrees with suggested editorial changes. The
'''''''''''''''''''''']
Final SE modified accordingly.
10 29 Section 2 should be Section 3 The NRC staff agrees with suggested editorial changes. The Final SE modified accordingly.
10 37-39 Highlighted information is The NRC staff agrees with proprietary, add proprietary brackets suggested editorial changes. The Final SE modified accordingly.
Attachment
Page Line Proposed Change/Comment NRC Response 10 42 Highlighted information is The NRC staff agrees with proprietary, add proprietary brackets suggested editorial changes. The Final SE modified accordingly.
11 14, 15 Highlighted information is The NRC staff agrees with proprietary, add proprietary brackets suggested editorial changes. The Final SE modified accordingly.
11 32, 33 Delete highlighted proprietary The NRC staff agrees with brackets, information is not suggested editorial changes. The proprietary Final SE modified accordingly.
12 2, 3 Highlighted information is The NRC staff agrees with proprietary, add proprietary brackets suggested editorial changes. The Final SE modified accordingly.
16 33 What additional limitations are being The particular paragraph in question referred to here? was modified in the final SE to provide clarification.
17 14, The NRC staff agrees with Replace BAW-1033P with BAW-27, & suggested editorial changes. The 10133P-A 33 Final SE modified accordingly.
19 27-32 Highlighted information is The NRC staff agrees with proprietary, add proprietary brackets suggested editorial changes. The Final SE modified accordingly.
21 24 Highlighted information is The NRC staff agrees with proprietary, add proprietary brackets suggested editorial changes. The Final SE modified accordingly.
21 49, 50 Highlighted information is The NRC staff agrees with proprietary, add proprietary brackets suggested editorial changes. The Final SE modified accordingly.
22 2-5 Highlighted information is The NRC staff agrees with proprietary, add proprietary brackets suggested editorial changes. The Final SE modified accordingly.