Drawing 8770-B-327, Rev. 59. Extension, Control Wiring Diagram Index. Sheet 5
ML18127B289
Person / Time
Site: Saint Lucie 
(DPR-067)
Issue date: 05/11/2001
From:
Ebasco Services
To:
Florida Power & Light Co, Office of Nuclear Reactor Regulation
References
8770-B0327, Rev 59
Download: ML18127B289 (1)


Text

SHEET NO REV NO SHEET NO REV NO SHEET NO REV NO 591 592

< 593 594 595 596 597 598 599 601 602 603 604 605 606 607 609 610 611 612 613 614 1

.I 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 631 632 633 634 635 636 641 STATlON AIR COMPRESSOR INSTRUMENT 8c STATION AIR INSTRUMENTATION INSTRUMENT AIR COMPRESSOR 1A 8c DRYER 1A INSTRUMENT AIR COMPRESSOR 1B & DRYER 1B CONTAINMENT INSTRUMENT AIR COMPRESSOR 1A CONTAINMENT INSTRUMENT AIR COMPRESSOR 1B HYDROGEN RECOMBINER 1A HYDROGEN RECOMBINER 1B CONTAINMENT INSTRUMENT AIR DRYER 1A 8c 1B INSTRUMENT AIR COMPRESSOR EMERG COOUNG SYS AUX FW HDR A 8c B FLOW 8c PRESSURE AUX FW HDR C FLOW 8c PRESSURE 8c FWP 1A & 1B FLOW SG 1A 8c 1B ATM STM DUMP 8c FWP DISCH HDR PRESS CONDENSATE PUMP 1C CONDENSATE PUMP 1A CONDENSATE PUMP 1B FW 8c COND PH CONDUCTIVITY & FW DISSOLYED Q RECORDERS AUX FWP 1A DISCHARGE TO ST GEN 1A MY-09-9 AUX FWP 1B DISCHARGE TO ST GEN 1B MV-0910 AUX FWP 1A DISCHARGE TO ST GEN 1B MY-09-13 AUX FWP 1B DISCHARGE TO ST GEN 1A MV-09-14 AUX FWP 1C DISCHARGE TO ST GEN 1A MY-09-11 AUX FWP 1C DISCHARGE TO ST GEN 1B MV-0912 FWP 1A/1B DISCHARGE TO STEAM GEN 1A HCV-09-7 FEEDWATER PUMP 1A i

FEEDWATER PUMP 1A DISCHARGE VALVE MV-09-1 FEEDWATER PUMP 1A REQRC YALVES FEEDWATER PUMP 1A AUX OIL PUMP FEEDWATER REGULATING SYSTEM 1A FEEDWATER PUMP 1B FEEDWATER PUMP 1B DISCHARGE VALVE MV-09-2 FEEDWATER PUMP 1B RECIRC VALYES FEEDWATER PUMP 1B AUX OIL PUMP FEEDWATER REGULATING SYSTEM 1B HEATER DRAIN PUMP 1A HEATER DRAIN PUMP 1B FW REGULATING SYSTEM 1A & 1B FLOW 8c INDICATION FWP 1A & 1B BEARING TEMP & SGFW SEAL LEAK OFF TK LVL AUX FEEDWATER PUMP 1A AUX FEEDWATER PUMP 1B AUX FEEDWATER PUMP 1C TURBINE AUX FEEDWATER PUMP 1C STEAM YALVE MY-083 FW PUMP 1A/1B DISCHARGE TO STEAM GEN 1B HCV-09-8 FEEOWATER REG BLOCK VALVE MV-095 FW REG 100K BYPASS VALVE MV-09-3 FEEDWATER REG BLOCK VALVE MV-096 FW REG 100K BYPASS YALVE MV-09-4 AUX FWP 1C TURB GOV & CONTROL PANEL SGB RATE CONTROL 8c CONDENSATE CONDUCTIVITY TEMP STRAINERS DIFF PRESS ALARMS HTR DRAIN 8c STA MISC ANNUNQATOR "F SH 1 RTGB-102 642 643 645 647 648 649 651 652 653 654 659 660

. 661 662 663 665 666 667 668 669 670 671 672 673 674 675 676 687 REV DATE BY 693 694 695 699 701 702 703 704 705 706 707 709 710 711 712 713 714 715 716 717 718 719 720 721 724 726 727 728 731 732 734 735 CHLORINATION SYSTEM-3 CHLORINATION SYSTEM-4 AUX FWP 1C 8c TURB iNLET PRESS 8c STM GEN FLOW 8c PRESSURE REHEATER CONTROL RHTR 1A MAIN STEAM BLOCK VALYE MV-084 RHTR 1A MAIN STEAM WARM-UP VALVE MY-08-5 RHTR 1D MAIN STEAM BLOCK YALYE MV08-6 RHTR 10 MAIN STEAM WARM-UP VALVE MV-087 RHTR 1B MAIN STEAM BLOCK VALVE MV-088 RHTR 1B MAIN STEAM WARM-UP VALVE MY08-9 RHTR 1C MAIN STEAM BLOCK VALVE MV0810 RHTR 1C MAIN STEAM WARM-UP VALYE MV-08-11 TURBINE TRIP STM GEN HlHl LEVEL TURBINE AUTO-STOP-TRIP & TURBINE ALARMS EMERGENCY TURBINE TRIP 8c TURBINE ALARMS TURBINE RUNBACK THROTTLE 8c GOVERNOR VALVE INDICATING LIGHTS THROTTLE 8c GOVERNOR VALVES LEFT THROTTLE 8c GOVERNOR VALVES RIGHT INTERCEPT & REHEAT STOP YALVE TEST GOVERNOR CONTROL CABINET INTERCEPT 8c REHEAT STOP VALVE INDICATING LIGHTS DEH CONTROL CABINET INTERCONNECTING CABLES DEH GOVERNOR FLUID PUMP 1A-MP1 OEH GOVERNOR FLUID PUMP 1B-MP2 H2 DETECTION INSIDE EXQTER HOUSING BEARING OIL PUMP BOP SEAL OIL BACK-UP PUMP SOB EMERGENCY OIL PUMP EOP TURNING GEAR-TG TURNING GEAR AUTOMATIC CONTROL TG BEARING OIL UFT PUMP BL TURBINE LUBE OIL TRANSFER PUMP TURB LUBE OIL COND, TURB LUBE OIL FILTER PUMP 8c LUBE OIL FILTER BLOWER OIL VAPOR EXTRACTOR (OIL RESERVOIR) OER EBASCO SERVICES INCORPORATED NEW YORK FLORIDA POWER 8c LIGHT COMPANY ST LUCIE PLANTEXTENSIONUNIT 1

CONTROL WIRING DIAGRAM APPROVED R C HAEKLER 8770- B-327 V.O.

M.M.

INDEX SHEET 5 FILE: USC00018 HTR DRAIN & STA MISC ANNUNCIATOR "F" SH 2 RTGB-102 RTGB-102 120V VITAL AC 8c 45Y DC DISTRIBUTION RTGB 125V DC 8c 120Y AC DISTRIBUTION RTGB-105 120V AC 8c 125V DC DISTRIBUTION RTGB-106 45Y DC 8c 120V AC MEAS CHANNELS DISTRIBUTION RTGB-106 120V AC 8c 125V DC DISTRIBUTION SH 1

RTGB-106 120V AC 8c 125V DC DISTRIBUTION SH 2 HSCP 1A, 1B, 1AB 120V AC DISTRIBUTION CONDENSATE FW ANNUNQATOR "G" SH 1

RTGB102 CONDENSATE FW ANNUNQATOR "G" SH 2 RTGB-102 SG 1A TO AFWP1C TURBINE MV-08-13 SG 1B TO AFWP-1C TURBINE MY-08-14 LOW POWER FW AUTO CONTR SYSTEM 1A 8c 1B LP HEATERS 3A & 3B DRAIN CONTROL HEATERS 4A, 4B, 5A, 8c 5B DRAIN CONTROL THERMOCOUPLE INPUTS TO INDICATOR Tl-09-5 SH 1

THERMOCOUPLE INPUTS TO INDICATOR Tl-09-5 SH 2 THERMOCOUPLE INPUTS TO INDICATOR Tl-09-5 SH 3 LP HEATERS 1A 8c 1B DRAIN CONTROL LP HEATERS 2A 8c 2B DRAIN CONTROL HEATER LEVEL ALARMS MOISTURE SEPARATOR & DRAIN COLLECTOR, DRAIN TO HOTWELL VA'S HEATER DRAINS 8c AUX STM SYSTEM MISC INST & CONTROL DRAIN COLL 8c MOISTURE SEPARATOR REHTR LEVEL ALARMS VOID CHLORINATION SYSTEM 1 CHLORINATION SYSTEM -2 CHEMICAL FEED PUMPS-1 CHEMICAL FEED PUMPS-2 ELEC 8c CLRNTN ROOMS EXH FANS HVE 26 8c 27 VOID RESERVED 58 S/16/93 ~

57 S/16/93 "

RSC DG JPP RJF CAA YJC APPROVED DIV: I8cC DR:

BT RM DATE; 05 26 72 REY DATE BY APPROVED