ML18116A012
| ML18116A012 | |
| Person / Time | |
|---|---|
| Issue date: | 04/24/2018 |
| From: | Michael Turner Acquisition Management Division |
| To: | Nekulak K Brookhaven National Lab (BNL) |
| References | |
| NRC-HQ-25-14-D-0002 | |
| Download: ML18116A012 (15) | |
Text
04/24/2018
2 IAA NO PAGE OF 2
ORDER NO NRC-HQ-20-16-T-0013/M0006 responses; and (4)) extend the period of performance end date by six (6) months, from August 28, 2018 to February 28, 2019.
Accordingly the task order is modified as follows:
Attachment No. 1 entitled, Final Revised Statement of Work," is hereby deleted in its entirety and replaced with the Statement of Work attached to this Modification No. 6 entitled, "Statement of Work (SOW) - Revision 2."
Amount Obligated This Action: $55,000.00 Total Obligated Amount to Date: $428,167.00 (Changed)
Total Authorized Ceiling Amount: $481,081.00 (Changed)
Period of Performance: 08/29/2016 to 02/28/2019(Changed)
All other terms and conditions of the task order remain unchanged.
DUNS: 040535809 TAS: 31X0200.320 ALC: 31000001
1 NRC-HQ-20-16-T-0013 STATEMENT OF WORK (SOW) - REVISION 2 NRC Agreement Number NRC-HQ-25-14-D-0002 NRC Agreement Modification Number NRC Task Order Number (If Applicable)
NRC-HQ-20-16-T-0013 M0006 NRC Task Order Modification Number (If Applicable)
Project Title Technical Assistance in Support of Review of AREVA Topical Report ANP-10332P, "AURORA-B: An Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios" Job Code Number B&R Number Servicing Agency BNL NRC Requisitioning Office NRR Period of Performance 8/29/2016-02/28/2019 NRC Form 187, Contract Security and Classification Requirements
[ ] Applicable
[X} Not Applicable
[X] Involves Proprietary Information
[ ] Involves Sensitive Unclassified
[ ] Non Fee-Recoverable
[X] Fee-Recoverable (If checked, complete all applicable sections below)
Docket Number (If Fee-Recoverable/Applicable)
PROJ0728 Inspection Report Number (If Fee Recoverable/Applicable)
Technical Assignment Control Number (If Fee-Recoverable/Applicable)
MF3829 Technical Assignment Control Number Description (If Fee-Recoverable/Applicable)
AREVA NP INC. - ANP-10332P. REVISION 0, "AURORA-B: AN EVALUATION MODEL FOR WRS; APPLICATION TO LOSS OF COOLANT ACCIDENT
2 NRC-HQ-20-16-T-0013 DESCRIPTION/SPECIFICATIONS/WORK STATEMENT
1.0 BACKGROUND
AREVA topical report ANP-10332P presents a proprietary evaluation model for performing licensing-basis analysis for boiling-water reactors (BWRs) in response to a postulated loss-of coolant accident (LOCA) event. Topical report ANP-10332P describes a deterministic LOCA evaluation model that is intended to satisfy the required and acceptable emergency core cooling system (ECCS) evaluation model features specified in Appendix K to 10 CFR
- 50. If deemed acceptable, AREVA intends to use this method to perform LOCA analysis for BWRs to ensure satisfaction of the criteria of 10 CFR 50.46 (namely peak cladding temperature, maximum local oxidation, and core-wide oxidation).
The methodology described in ANP-10332P is based on a multi-physics code system known as AURORA-B. For the LOCA evaluation model, the AURORA-B code system relies upon two main components, S-RELAP5 (thermal-hydraulic system code) and RODEX4 (transient fuel thermal-mechanical behavior code). Up to the present time, AURORA-B and/or its constituent component codes have been or are in the process of being reviewed by the NRC staff on a number of other applications, including:
- EMF-2103PA, Realistic Large Break Loss-of-Coolant Accident Methodology for Pressurized Water Reactors
- EMF-2310PA, SRP Chapter 15 Non-LOCA Methodology for Pressurized Water Reactors
- BAW-10247PA, Realistic Thermal-Mechanical Fuel Rod Methodology for Boiling Water Reactors
- ANP-10300P, AURORA-B: An Evaluation Model for Boiling Water Reactors; Application to Transient and Accident Scenarios (currently under review)
- ANP-10333P, AURORA-B: An Evaluation Model for Boiling Water Reactors; Application to Control Rod Drop Accident (currently under review)
The NRC staff intends to maintain overall responsibility for the review of the topical report, whereas BNL shall be requested to provide focused technical assistance concerning the validation of the AURORA-B code system against test data that is applicable to the BWR LOCA event, including both separate effects and integral comparisons. This information is contained largely in Chapter 7 of the topical report, which comprises the bulk of the topical report.
5 NRC-HQ-20-16-T-0013 In light of the above discussion, BNL's review should focus on the following:
- The adequacy of the validation of specific models and correlations of highest importance to the BWR LOCA event,
- The adequacy of the validation of specific models and correlations that have been added or modified relative to implementations previously reviewed by the NRC staff (e.g., to support application to the BWR LOCA event, to support coupling of the constituent component codes together, or otherwise},
- Novel impacts from applying existing models and correlations to the BWR LOCA event, which may, for example, result in the use of existing models and correlations outside of ranges considered in the validation process for previous applications,
- The degree of adherence of specific models and correlations to the required and acceptable features of ECCS evaluation models set forth in 10 CFR 50, Appendix K,
- Consideration of whether the validation database used by AREVA is applicable and sufficient to support application of the AURORA-B code system to the analysis of the BWR LOCA event, and
- Review of additional code models and correlations, if justified in light of present knowledge and recent developments.
Upon completion of our acceptance review for ANP-10332P, the NRC staff will provide additional guidance regarding the specific models and correlations to which BNL should pay special attention during the review.
2.0 OBJECTIVE The objective of this task order is to obtain technical assistance in support of the NRC staff's determination concerning whether the subject topical report (ANP-10332P) is technically accurate and meets applicable regulatory requirements. The NRC technical staff will participate in this review and retain overall project leadership. Technical assistance from BNL is being requested in the specific area of ensuring adequate validation of the models and correlations in the AURORA-B code system for performing licensing-basis BWR LOCA analysis in accordance with the requirements of Appendix K to 10 CFR 50. The information to be reviewed by BNL is contained largely in Chapter 7 of ANP-10332P.
The objective of this modification is to increase the level of effort. BNL was required to draft a large number of requests for additional information (RAIs) to support the review. As a result, more effort was required than initially anticipated to prepare the RAIs, and increased contractor effort will be required to review the responses from the vendor. Furthermore, because the vendor desires to receive a draft safety
6 NRC-HQ-20-16-T-0013 evaluation by the vendor has proposed to have regular teleconference discussions with the NRC staff and BNL that were not originally anticipated. Preparing for and participating in these teleconference discussions will require additional effort from BNL.
3.0 SCOPE OF WORK/TASKS The NRC will furnish a copy of topical report ANP-10332P and other supporting documentation in our possession. Beyond this, BNL shall provide all resources necessary to accomplish the tasks and deliverables described in this statement of work (SOW). BNL shall provide technical review resources for evaluating the validation of the models and correlations used in the AURORA-B code system, as described primarily in Chapter 7 of AREVA's topical report ANP-10332P.
The services include supporting a kick-off meeting, reviewing relevant portions of ANP-10332P, traveling to NRC Headquarters or vendor's office to perform one or more regulatory audits (if necessary), participating in periodic telephone conference calls with the vendor, identifying issues and draft requests for additional information (RAls), evaluating vendor's RAI responses, providing a technical evaluation report, and supporting the NRC staff during the associated Advisory Committee on Reactor Safeguards (ACRS) meeting (if applicable).
Task 1: Kick-off Meeting The serving agency shall participate in a telephone conference call orientation/kick-off meeting with the NRC staff to discuss the scope of the work, expectations and contract management.
BNL shall provide a technical letter report. (See Section 8.2 for Technical Letter Report requirements).
Task 2: Supporting Regulatory Audit of Topical Report The staff from BNL shall prepare for and travel to NRC headquarters or the vendor site for a regulatory audit of topical report that focuses on outstanding questions generated by the NRC staff and servicing agency review effort to date (if deemed necessary by NRG GOR).
Subtask 2a: One week prior to the audit, BNL shall submit a list of outstanding questions generated from the review of the topical report to date to support discussion with AREVA during the audit.
Subtask 2b: Within two weeks of completion of the audit, BNL shall prepare and submit a trip report via email. (See Section 8.2 for Trip Report requirements)
Task 3: Evaluation of Topical Report Based upon its review of the validation of the models and correlations of the AURORA-8 code system, as discussed in Chapter 7 of AREVA's topical report ANP-10332P, the serving agency shall provide a draft Technical Evaluation Report (TER) with open items which presents the technical evaluation of the applicant's topical report against the NRC's
7 NRC-HQ-20-16-T-0013 regulations and guidance. Portions of the topical report which have been found acceptable should be fully documented.
Draft RAls based upon the remaining open items must be provided to the NRC COR. The draft RAls should clearly and concisely identify the information being requested, briefly note the regulatory basis for the request, and have a direct connection with an open item. These RAls are to be emailed to the NRC COR along with the draft TER with open items. (See Section 8.2 for Technical Evaluation Report requirements).
Task 4: Supporting Regulatory Audit of RAI Responses The staff from BNL shall prepare for and travel to NRC headquarters or the vendor site for a regulatory audit of AREVA RAI responses (which may be in draft form) that focuses on the adequacy of the approach AREVA is using to resolve the outstanding RAI questions (if deemed necessary by NRG GOR).
Within two weeks of completion of the audit, BNL shall prepare and submit a trip report via email. (See Section 8.2 for trip report requirements)
Task 5: Review and Evaluation of RAI Responses BNL shall review and evaluate the RAI responses formally submitted by the vendor to determine whether or not the responses address the concerns identified in the original RAI.
BNL shall prepare and submit an updated version of the draft TER provided under Task 3, which includes documentation of the RAI response evaluation. For RAI responses that are unacceptable, formulate follow-up RAl(s).
BNL shall review the vendor's response(s) to the follow-up RAl(s) and submit a revised TER documenting the evaluation. (See Section 8.2 for TER requirements)
Task 6: Prepare Presentation for ACRS Meeting(s)
BNL shall support NRC staff by providing draft slide presentation summarizing key issues of their evaluation pertaining to ANP-10332P to be used as part of the NRC staff presentation to the ACRS (if deemed necessary by NRG COR). If requested by NRC COR, BNL must attend the ACRS meeting.
4.0 LIST OF DELIVERABLES The following is a list of deliverables and the corresponding due dates that are to be delivered by BNL to the COR during performance of the requirements:
8 NRC-HQ-20-16-T-0013 Task Number Deliverable and Acceptance Criteria Deliverable Format Due Date 1
Technical Letter Report Acceptance Criteria: Summary of kickoff meeting as detailed in SOW Section 8.2 Microsoft Word NLT 14 days from completion of kickoff meeting 2a Technical Letter Report (If Applicable)
Acceptance Criteria: Report contains all required information as detailed in SOW Section 8.2 Microsoft Word NLT 7 days prior to audit 2b Trip Report (If Applicable)
Acceptance Criteria: Report contains all required information as detailed in SOW Section 8.2 Microsoft Word NLT 14 days from completion of audit 3
Technical Evaluation Report Acceptance Criteria: Report includes required information as detailed in SOW Section 8.2 Microsoft Word Draft Report - 6 months from date of award Final report - 2 weeks from receipt of comments from the NRC Technical Monitor 4
Trip Report (If Applicable)
Acceptance Criteria: Report contains all required information as detailed in SOW Section 8.2 Microsoft Word NLT 14 days from completion of audit 5
Technical Evaluation Report Acceptance Criteria: Report includes required information as detailed in SOW Section 8.2 Microsoft Word Draft Report - 1 month from date receipt of AREVAs RAI responses Final report - 2 weeks from receipt of comments from the NRC Technical Monitor 6
ACRS Slide Presentation (If Applicable)
PowerPoint Draft Slides: Two weeks prior to the ACRS meeting Final Slides: Two days after receipt of NRC comments All Per SOW Section 8.1, Monthly Letter Status Reports (MLSRs)
Acceptance Criteria: Report contains all required information Microsoft Word or Adobe PDF NLT than 20th of the following month 5.0 LABOR CATEGORIES AND KEY PERSONNEL 5.1 Labor Categories, Requirements and Key Personnel. Personnel working under this agreement/order shall meet the minimum requirements for experience and education, as follows:
10 NRC-HQ-20-16-T-0013 Labor Category Position Minimum Requirements Key Personnel*
(yes or no)
Senior Key Staff Expertise in the area of thermal-hydraulic system code and fuel thermal-mechanical analysis for the BWR LOCA event. Knowledge of the body of test data available for benchmarking thermal-hydraulic code models and correlations for this event. Past experience either performing or reviewing code validation efforts for the BWR LOCA event.
Yes 5.2 Changes to Senior Key Staff. BNL shall notify the COR and the NRC technical monitor sufficiently early regarding any senior staff.changes during the review. BNL shall consult with the COR and the technical monitor about the expertise and experience of the new senior key staff. The NRC reserves the right to terminate or modify the agreement if the agency is not fully satisfied with the new senior staff assigned to the review.
6.0 MEETINGS AND TRAVEL Telephone conference call/kickoff meeting with servicing agency, the NRC Technical Monitor, and the COR.
The following travel assumptions should be considered in planning the work effort. It is likely that a smaller group than the entire review team will be necessary to accomplish some activities. The actual travel will be determined by the COR after discussion with the laboratory PM (and PTL). At the discretion of the COR, meetings may be conducted via telephone or video conference. It is anticipated that the following travel will be required:
- Two 2-persons, 4-day trip to vendor's location or NRC Headquarters (Task 2)
- Two 2-persons, 4-day trip to vendor's location or NRC Headquarters (Task 4)
- Two 2-persons, 3-day trip to NRC headquarters for ACRS meeting (Task 6)
Servicing agency personnel will be authorized travel expenses consistent with the Federal Travel Regulation (FTR) and the limitation of funds specified for the travel within this agreement/order. All travel requires prior written approval from the COR.
Foreign travel for BNL personnel requires a 60-day lead time for NRC approval. For prior approval of foreign travel, BNL shall submit to the COR an NRC Form 445, "Request for Approval of Official Foreign Travel." NRC Form 445 is available in the MD 11.7 Documents library and on the NRC Web site at: http://www.nrc.gov/reading-rm/doccollections/forms/. All foreign travel requires prior written approval from the NRC Executive Director for Operations (EDO).
7.0 REPORTING REQUIREMENTS BNL is responsible for structuring the deliverables to current agency standards. The current agency standard is Microsoft Office Suite 2010. The current agency Portable Document Format (PDF) standard is Adobe 9 Professional. Deliverables shall be submitted free of spelling and grammatical errors and shall conform to requirements stated in this section.
11 NRC-HQ-20-16-T-0013 7.1 Monthly Letter Status Report (MLSR)
BNL shall provide a Monthly Letter Status Report which consists of a technical progress report and financial status report. This report will be used by the NRC to assess the adequacy of the resources utilized by BNL to accomplish the work contained in this SOW and to provide status of BNL progress in achieving tasks and producing deliverables. The report shall include agreement/order summary information, work completed during the specified period, milestone schedule information, problem identification and resolution, travel plans, and staff hour summary.
7.2 Technical Reporting Requirements
- 1. At the completion of Task 1, submit technical letter report that contains a summary of the meeting, discussions held, and decisions reached.
- a. One week prior to the audit described in Task 2, submit technical letter report that contains outstanding questions based upon review of topical report to date. The questions included in technical letter report will be used to support audit discussions with AREVA.
- b. At the completion of Task 2, submit trip report that contains a summary of the audit, including discussions held, outcomes and proposed additional information items that should be requested from vendor to support the review. Include copy of the slides or other visuals used (not necessary if the staff indicates they already have them).
- 2. At the completion of Task 3, submit technical evaluation report, draft and final as appropriate, that contains input summarizing the review and providing preliminary conclusions. The technical evaluation report should also identify additional information needed to complete the review in the form of draft RAls. The technical evaluation report and draft RAls should follow the guidance, format, and content shown in attachments 1 and 2
- 3. At the completion of Task 4, submit trip report that contains a summary of the audit, including discussions held, outcomes and proposed additional information items that should be requested from vendor to support the review. Include copy of the slides or other visuals used (not necessary if the staff indicates they already have them).
- 4. At the completion of Task 5, submit technical evaluation report, draft and final as appropriate, that contains revised input, open items, and proposed conditions and limitations. The report should follow the guidance, format, and content shown in Attachment 2.
NOTE: All reports are be submitted electronically using MS WORD or compatible software program to the Technical Monitor with a copy provided the COR. The transmittal letter and cover page shall contain task order number, title, and NRC cost activity code (CAC).
12 NRC-HQ-20-16-T-0013 8.0 CONTRACTING OFFICER'S REPRESENTATIVE Contracting Officer's Representative Name: Leslie Perkins Agency: U.S. Nuclear Regulatory Commission Office: NRR/DPR/PLPB Mail Stop: OWFN 12D20 Washington, DC 20555 leslie.perkins@nrc.gov Phone: (301) 415-2375 Alt. Contracting Officer's Representative Name: Brian Harris Agency: U.S. Nuclear Regulatory Commission Office: NRR/DPR/PGCB Mail Stop: OWFN 12D20 Washington, DC 20555 brian.harris2@nrc.gov Phone: (301) 415-2277 Technical Monitor Name: John Lehning Agency: U.S. Nuclear Regulatory Commission Office: NRR/DSS/SNPB Mail Stop: OWFN 10 A 01 Washington, DC 20555 john.lehning@nrc.gov Phone: (301) 415-1015 9.0 PERIOD OF PERFORMANCE The period of performance of this task order is August 29, 2016 through February 28, 2019.
10.0 APPLICABLE PUBLICATIONS (CURRENT EDITIONS)
- NUREG-0800, Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants: LWR
- Title 10 Code of Federal Regulations
- Regulatory Guide 1.203, Transient and Accident Analysis Methods
13 NRC-HQ-20-16-T-0013 11.0 DATA RIGHTS The NRC shall have unlimited rights to and ownership of all deliverables provided under this agreement/order, including reports, recommendations, briefings, work plans and all other deliverables. All documents and materials, to include the source codes of any software, produced under this agreement/order are the property of the NRC with all rights and privileges of ownership/copyright belonging exclusively to the NRC. These documents and materials may not be used or sold by BNL without prior written authorization from the CO. All materials supplied to the NRC shall be the sole property of the NRC and may not be used for any other purpose. This right does not abrogate any other Government rights.
12.0 NRC-FURNISHED PROPERTY/MATERI ALS A copy of AREVA Topical Report ANP-10332P, "AURORA-8: An Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios," will be made available to BNL. Copies of relevant supporting documentation will be provided, including access to previously approved licensing topical reports that are necessary to perform the review.
NOTE: These documents contain proprietary information and must be safeguarded against unauthorized disclosure. After completion of work, the documents should either be destroyed or returned to NRC. If they are destroyed, please confirm this in an E-mail to the Contracting Officer's Representative(s) with a copy to the Project Officer and include the date and manner in which the documents were destroyed.
14 NRC-HQ-20-16-T-0013 Guidance for Preparing Requests for Additional Information (RAls)
Additional information necessary to resolve open or unresolved items identified during the review of the information associated with the Topical Report needs to be requested in a manner that is unambiguous, has an adequate basis, and is necessary for the safety review. The technical letter report described in Technical Reporting Requirements should provide a list of RAls using the following guidance:
- 1. An RAI should include the appropriate basis for requesting the information. The basis should explain why the information is needed, including how it will be used to help make a reasonable assurance finding.
- 2. Judgmental language should be avoided.
- a. Questions should not make adequacy determinations.
- b. Words like "unacceptable," "deficient," and "deviation" should be avoided. Likewise, avoid using phrases like "the staff will require" since it is premature to require anything when asking questions.
- 3. Questions should be focused, not open-ended.
- a. The RAI should be in the form of a question or an imperative to provide what is needed to complete the review. When the reviewer needs specific information or the underlying issue may not be apparent, the RAI should clearly identify the information requested and/or the underlying issue.
After the RAls have been forwarded to the technical monitor, teleconferences and/or public meetings may be held before issuing the RAls:
- a. These discussions prevent misunderstandings of the intent of the questions.
- b. If a draft RAI is clarified or resolved before issuance, the NRC staff will prepare a documented record of the resolution (i.e., minutes of a public meeting or a teleconference summary).
After the RAls have been issued, the applicant may request a telephone conference and/or a public meeting:
15 NRC-HQ-20-16-T-0013 Enclosure 1
- a. The teleconferences and/or meetings provide additional clarification of the intent of the RAls and will help the applicant prepare satisfactory responses.
- b. To ensure that the response appropriately addresses the RAI, the applicant may submit a draft response (which the NRC Project Manager dockets in the Agency-Wide Documents Access and Management System (ADAMS)) and may request a follow-up teleconference and/or meeting.
After receiving the applicant's response to the RAI, the technical monitor may hold a teleconference and/or a public meeting. The purpose of discussing a response with the applicant is to better understand the response and/or clarify areas of disagreement. If the resolution of a response relies on information not submitted to the NRC, the applicant should submit the information on the docket. Only docketed information will be taken into consideration when determining the staff's conclusion.
NRC-HQ-20-16-T-0013 Enclosure 2 Content. Outline, and Format for Technical Evaluation Report 1.0 Introduction Summary of Work Performed: Describe the requested action. Outline the methodology used (by the Pl) for evaluating the topical report.
2.0 Regulatory Evaluation and Criteria Describe the regulations and regulatory guidance that the validation process for the models and correlations in the AURORA-B code system is intended to satisfy.
Primarily, this would include relevant steps in the evaluation model development and assessment process, as described in Regulatory Guide 1.203, upon which the topical report structure is modeled. Discussion of applicable sections from the Standard Review Plan (e.g., 15.0.2, 15.6.5) that are relevant to evaluation model validation is also appropriate.
3.0 Technical Evaluation The structure of the technical evaluation section should, insofar as reasonable, mirror the structure of the topical report, which is based on the evaluation model development and assessment process documented in Regulatory Guide 1.203.
3.1 Document your evaluation of the methodology, modeling, and supporting empirical and experimental database used for validation. Include language clearly linking how your assessment of the subject matter is supported (or not supported) by the supporting empirical and experimental database used for validation of the code.
3.2 Document any independent calculations performed in support of assessing the methodology. Provide a direct comparison of your independent results to those presented in the topical report.
3.3 Include a summary of significant RAls and corresponding responses in the appropriate sections of the TER. Extended quotations or historical accounts are not necessary; rather, a concise description of the issue, its significance, and its resolution is the objective.
3.4. Document the basis for acceptability of the methodology. Technical and regulatory conclusions must be justified by adequate evidence and logical reasoning.
4.0 Conclusion Clearly define any limitation or conditions related to the future application of the methodology.