UNITED STATES NUCLEAR REGULATORY COMMISSION REGION II 101 MARIETTA STREET, N.W.
ATLANTA, GEORGIA 30303 APR 11 1979 In Reply Refer To:
~~0-338
~
Virginia Electric and Power Company Attn:
Mr. W. L. Proffitt Senior Vice President Power Operations P. 0. Box 26666 Richmond, Virginia 23261 Gentlemen:
Based on our current understanding of the Three Hile Island accident sequence, and discussion with the designer of your pressurized water reactor, we have reason to believe that pressurizer level indication in your facility may not provide reliable information regarding level in the reactor coolant system under certain transient or accident condition.
You should immediately instruct your operating personnel accordingly.
In addition you should consider this possibility in responding to the enclosed bulletin.
Should you have any questions regarding this Bulletin or the actions required by you, please contact this office.
Enclosure IE Bulletin No. 79-06 with Enclosurf's cc w/encl:
Mr. W. L. Stevart, Manager P.O. Box 31S Surry, Virginia 23883 Sincerely,