FEB 2 2 1979
. Docket Nos. 50-280 and 50-291 DISTRIBUTION Docket File 50-280 and 50-281 NRG PDR Local PDR NRR Rdg ACRS(l6)
TERA J. Buchanan ORBl Rqg V. Stello Mr. W. L. Proffitt D E
- S.
V.
P
'd t P
. i sen hut enrnr 1ce res1 en ower.
R. Vollmer Virginia Electric and Power Company B. Grimes Post Office Box 26666 A. Schwencer Richmond, Virginia 23261 D. Ne,ghbors
Dear Mr. Proffitt:
P. Kreutzer We are currently reviewing the test report of environmental qualification testing performed on the Continental Instrument Cable in use at Surry Power Station. This report was su~mitted by your letter dated December 15, 1978.
We find that we need addi t iona 1 information in order for us to comp 1 ete
- \\,
our evaluation. It is requested that you provide the information.
identified in the enclosure within 30 days of receipt of this letter.
Enclosure:
Request for Additional Information cc: w/enclosure See next page Sincerely, A. Schwencer~ Chief Operating Reactors Branch #1 Division of Operating Reactors
\\
Ol"FIQB.. 1**RQ~l........ **************************.. Q.OH:
euRNAMI:.,
.. ~.Q~J};,~~;-~n'.'~.:. *.b......................... ASch mncer.............................................................................
DATE~
.. Qg/J;..:/.Z~.................................. 02e,~9....... ;..........................................................................
N&C FORM 318 (9*76) Mt.CM 0248 u.n. GOVKRNMENT PRINTING Qfl'pr1c11: 1111
- Zfll
- 711
1
---*,, __ _:. '- --**. ~**.. --*"---* ----*
e ENCLOSURE REQUEST FOR ADDITIONAL INFORMATION
- l. Provide the bases for concluding that thermal aging of cable samples at 100°c for 60 hours6.944444e-4 days <br />0.0167 hours <br />9.920635e-5 weeks <br />2.283e-5 months <br /> simulates an additional thirty three (33) years of in-plant use at a maximum ambient of $QOC~
These accelerated aging parameters were used in test sequence l on page 10 of the test report submitted with VEPCO letter dated December 15, 1978.
- 2. - Provide the test rep9rt from Ha veg Industries showing the data of the -
measurements of phys*ical and electrical properties of the cable samples. This report was committed to be forWarded as an Addendum to the test report (Refer to item 6, page 12 of the test report s~bmitted with VEPCO letter dated December 15, 1978).
- --- -----~--------------------