ENCLOSURE 1 HADDAMNECK INDEPENDENT SPENT FUEL STORAGE INSTALLATION ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY-DECEMBER2017 CY-18-010
HADDAM NECK INDEPENDENT SPENT FUEL STORAGE INSTALLATION License Nos. DPR-61 and SFGL-21 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT January - December 2017
"" {\\
',"-l *c,--
,..,..>y:::: RSCS 6: __ \\,
\\
Radia~on Saf~ty & Control Services April 2018 Prepared by:
Radiation Safety & Control Services 91 Portsmouth Avenue Stratham, NH 03885m2468
EXECUTIVE
SUMMARY
Tables 1 and 2 summarize the quantity of radioactive gaseous and liquid effluents, respectively, for each quarter of 2017. There were no gaseous or liquid releases in 2017. Table 3 summarizes waste shipped off-site for disposal for each half year of 2017. There was no waste shipped for disposal in 2017.
Appendices A and B indicate the status of reportable items per the requirements of the Off-site Dose Calculation Manual (ODCM). There were no reportable items in 2017.
Appendix C presents any changes in the ODCM. The ODCM was not revised in 2017.
CY 2017 Annual RER Report Page 2 of 15
Table 1 HADDAM NECK ISFSI Effluent and Waste Disposal Annual Report 2017 Gaseous Effluents-Summation of All Releases NLiclides Released*
.. Units; :, */1st
. 12nd*
- i.3rd,....
'**;. 4th
- * :Err~r * *:
' *. :Quarter Quarter* *Quarter** 'Quarter*
.,~,Fission and Activation Gases..,
Total Release Ci N/A*
N/A*
N/A*
N/A*
N/A*
Average release rate uCi/s N/A*
N/A*
N/A*
N/A*
Percent of regulatory limit N/A*
N/A*
N/A*
N/A*
- B." lodliles
" "*-* *-~. *'.
Total Iodines released Ci N/A*
N/A*
N/A*
N/A*
N/A*
Average release rate uCi/s N/A*
N/A*
N/A*
N/A*
Percent of regulatory limit N/A*
N/A*
N/A*
N/A*
. :C. *particulates' ** ** ::
~. '
Particulates Released Ci N/A*
N/A*
N/A*
N/A*
N/A*
Average release rate uCi/s N/A*
N/A*
N/A*
N/A*
Percent of regulatory limit N/A*
N/A*
NIA*
N/A*
Gross alpha radioactivity Ci N/A*
N/A*
N/A*
N/A*
D. Tritium
.. *~. '....
~ ':;-
C Total release Ci N/A*
N/A*
N/A*
N/A*
N/A*
Average release rate
µCi/s N/A*
N/A*
N/A*
N/A*
Percent of regulatory limit N/A*
N/A*
N/A*
N/A*
N/A*= Not Applicable There are no gaseous effluents associated with the Haddam Neck Independent Spent Fuel Storage Installation (ISFSI)
CY 2017 Annual RER Report Page 3 of 15
Table 1A HADDAM NECK ISFSI Effluent and Waste Disposal Annual Report 2017 Gaseous Effluents - Ground Level Releases - Batch Mode Nuclides Released Unit 1st 2nd 3rd 4th Total Quarter Quarter Quarter Quarter
- 1. Fission Gases Krypton-85 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Krvpton-85m Ci NIA*
NIA*
NIA*
NIA*
NIA*
Krypton-87 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Krypton-88 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Xenon-133 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Xenon-135 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Xenon-135m Ci NIA*
NIA*
NIA*
NIA*
NIA*
Xenon-138 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Unidentified Ci NIA*
NIA*
NIA*
NIA*
NIA*
Total for period Ci NIA*
NIA*
NIA*
NIA*
NIA*
- 2. lo<Hnas lodine-131 Ci NIA*
NIA*
NIA*.
NIA*
NIA*
lodine-133 Ci NIA*
NIA*
NIA*
NIA*
NIA*
lodine-135 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Total for period Ci NIA*
NIA*
NIA*
NIA*
NIA*
- 3. Particulates Strontium-89 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Strontium-90 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Cesium-134 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Cesium-137 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Cobalt-60 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Barium-Lanthanum-140 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Others-Plutonium-238 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Curium-243,244 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Uranium-234 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Uranium-238 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Thorium-232 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Radium-226 Ci NIA*
NIA*
NIA*
NIA*
NIA*
NIA*= Not Applicable There are no gaseous effluents associated with the Haddam Neck Independent Spent Fuel Storage Installation (ISFSI)
CY 2017 Annual RER Report Page 4 of 15
Table 18 HADDAM NECK ISFSI Effluent and Waste Disposal Annual Report 2017 Gaseous Effluents - Ground Level Releases - Continuous Mode Nuclldes Released Unit 1st 2nd 3rd 4th Total Quarter Quarter Quarter Quarter
- 1. *Fission Gases Krypton-85 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Krvpton-85m Ci NIA*
NIA*
NIA*
NIA*
NIA*
Krypton-87 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Krvpton-88 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Xenon-133 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Xenon-135 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Xenon-135m Ci NIA*
NIA*
NIA*
NIA*
NIA*
Xenon-138 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Un identified Ci NIA*
NIA*
NIA*
NIA*
NIA*
Total for period Ci NIA*
NIA*
NIA*
NIA*
NIA*
- 2. Iodines lodine-131 Ci NIA*
NIA*
NIA*
NIA*
NIA*
lodine-133 Ci NIA*
NIA*
NIA*
NIA*
NIA*
lodine-135 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Total for period Ci NIA*
NIA*
NIA*
NIA*
NIA*
- 3. Particulates Strontium-89 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Strontium-90 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Cesium-134 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Cesium-137 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Cobalt-60 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Barium-Lanthanum-140 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Others-Plutonium-238 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Curium-243,244 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Uranium-234 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Uranium-238 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Thorium-232 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Radium-226 Ci NIA*
NIA*
NIA*
'NIA*
NIA*
NIA*= Not Applicable There are no gaseous effluents associated with the Haddam Neck Independent Spent Fuel Storage Installation (ISFSI)
CY 2017 Annual RER Report Page 5 of 15
Table 1C HADDAM NECK ISFSI Effluent and Waste Disposal Annual Report 2017 Gaseous Effluents - Elevated Releases - Batch Mode Nuclides Released Unit 1st 2nd 3rd 4th Total Quarter Quarter Quarter Quarter
- 1. Fission Gases Krvpton-85 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Krypton-85m Ci NIA*
NIA*
N/A*
NIA*
NIA*
Krvpton-87 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Krypton-88 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Xenon-133 Ci NIA*
NIA*
N/A*
NIA*
NIA*
Xenon-135 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Xenon-135m Ci NIA*
NIA*
NIA*
NIA*
NIA*
Xenon-138 Ci NIA*
NIA*
NIA*
NIA*
NIA*
- Unidentified Ci NIA*
N/A*
N/A*
NIA*
NIA*
Total for period Ci NIA*
NIA*
NIA*
NIA*
NIA*
- 2. lodinas lodine-131 Ci NIA*
NIA*
NIA*
NIA*
NIA*
lodine-133 Ci NIA*
NIA*
N/A*
NIA*
NIA*
lodine-135 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Total for period Ci NIA*
NIA*
NIA*
NIA*
NIA*
- 3. Particulates Strontium-89 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Strontium-90 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Cesium-134 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Cesium-137 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Cobalt-60 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Barium-Lanthanum-140 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Others-Plutonium-238 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Curium-243,244 Ci NIA*
NIA*
NIA*
N/A*
NIA*
Uranium-234 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Uranium-238 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Thorium-232 Ci N/A*
NIA*
NIA*
NIA*
NIA*
Radium-226 Ci NIA*
NIA*
NIA*
NIA*
NIA*
NIA*= Not Applicable There are no gaseous effluents associated with the Haddam Neck Independent Spent Fuel Storage Installation (ISFSI)
CY 2017 Annual RER Report Page 6 of 15
Table 1D HADDAM NECK ISFSI Effluent and Waste Disposal Annual Report 2017 Gaseous Effluents - Elevated Releases - Continuous Mode Nuclides Released Unit 1st 2nd 3rd 4th Total Quarter Quarter Quarter Quarter
- 1. Fission Gases Krvpton-85 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Krypton-85m Ci NIA*
NIA*
NIA*
NIA*
NIA*
Krvpton-87 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Krypton-88 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Xenon-133 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Xenon-135 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Xenon-135m Ci NIA*
NIA*
NIA*
NIA*
NIA*
Xenon-138 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Unidentified Ci NIA*
NIA*
NIA*
NIA*
NIA*
Total for period Ci NIA*
NIA*
NIA*
NIA*
NIA*
- 2. Iodines lodine-131 Ci NIA*
NIA*
NIA*
NIA*
NIA*
lodine-133 Ci NIA*
NIA*
NIA*
NIA*
NIA*
lodine-135 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Total for period Ci NIA*
NIA*
NIA*
NIA*
NIA*
- 3. Particulates Strontium-89 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Strontium-90 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Cesium-134 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Cesium-137 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Cobalt-60 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Barium-Lanthanum-140 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Others-Plutonium-238 Ci NIA*.
NIA*
NIA*
NIA*
NIA*
Curium-243,244 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Uranium-234 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Uranium-238 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Thorium-232 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Radium-226 Ci NIA*
NIA*
NIA*
NIA*
NIA*
NIA*= Not Applicable There are no gaseous effluents associated with the Haddam Neck Independent Spent Fuel Storage Installation (ISFSI)
CY 2017 Annual RER Report Page 7 of 15
Table 2 HADDAM NECK ISFSI Effluent and Waste Disposal Annual Report 2017 Liquid Effluents - Summation of All Releases
. *... Nuclides :Released-Uri1t*
1*t, ::-:-- 2nd':.
- "3rd*: *,
4th
- -Error
- Quarter ':Quarter ' :Quarter.. :Quarter* -. **:*'
A. Fission and Activation Products Total Release (not including Ci tritium, Qases, alpha)
Average diluted concentration during period Percent of applicable limit B. Tritium Total Release Average diluted concentration during period
µCi/ml Ci
µCi/ml Percent of applicable limit C. Dissolved and Entrained Gases Total Release Ci Average diluted concentration
µCi/ml durinQ period Percent of applicable limit D. Gross Alpha Radioactivity Total release Ci Average diluted concentration
µCi/ml NIA*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
NIA*
N/A*
N/A*
NIA*
NIA*
NIA*
NIA*
N/A*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
N/A*
~
NIA*
NIA*.
N/A*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
N/A*
NIA*
NIA*
NIA*
NIA*
NIA***
NIA*
N/A*
N/A*
N/A*
NIA*
NIA*
NIA*
durinQ period 1--~~~~~~~~~~--+-~~--+-~~~-+-~~~-+-~~~1--~~----l*.
E. Volume of Waste Released Liters (prior to dilution)
F. Volume of Dilution Water Used During Period NIA*= Not Applicable Liters NIA*
N/A*
NIA*
NIA*
N/A*
NIA*
NIA*
NIA*
There are no liquid effluents associated with the Haddam Neck Independent Spent Fuel Storage Installation (ISFSI)
CY 2017 Annual RER Report Page 8 of 15
Table 2A HADDAM NECK ISFSI Effluent and Waste Disposal Annual Report 2017 Liquid Effluents - Batch Mode Strontium-89 Strontium-90 Cesium-134 Cesium-137 lodine-131 Cobalt-58 Cobalt-60 lron-59 Zinc-65 Manaanese-54 Chromium-51 Zircon ium-Niobium-95 Molybden um-99 Technetium-99m Barium-Lathanium-140 Cerium-141 Others-Iron-55 Antimony-125 Unidentified Total for period (above)
Dissolved and Entrained Gasses Tritium Gross Aloha Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci NIA*= Not Applicable 1st,
- duartef' NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
- .2nd.
3rd.
,4th :
Totals.
Quaiter c* Quarter ' ' Quarter: ' -
~. '
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
, NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
There are no liquid effluents associated with the Haddam Neck Independent Spent Fuel Storage Installation (ISFSI)
CY 2017 Annual RER Report Page 9 of 15
Table2B HADDAM NECK ISFSI Effluent and Waste Disposal Annual Report 2017 Liquid Effluents - Continuous Mode
- NuclidesJ~.a_"leas_a_d
- Unit_. *
- 1st_:
-,2nd * -
. Quarter ;.. Quarter ;*-
-_____ ird _ *.
_-.. *,,:4th - *
~Quarter : **Quarter-
- _Tqtals Strontium-89 Strontium-90 Cesium-134 Cesium-137 lodine-131 Cobalt-58 Cobalt-60 lron-59 Zinc-65 Manganese-54 Chromium-51 Zirconium-Niobium-95 Molybdenum-99 Technetium-99m Barium-Lathanium-140 Cerium-141 Others-lron-55 Antimony-125 Unidentified Total for period (above)
Dissolved and Entrained Gasses Tritium Gross Alpha NIA*= Not Applicable Ci N/A* -
NIA*
NIA*
NIA*
Ci NIA*
NIA*
N/A*
NIA*
Ci NIA*
NIA*
NIA*
NIA*
Ci NIA*
NIA*
NIA*
NIA*
Ci NIA*
NIA*
NIA*
NIA*
Ci NIA*
NIA*
NIA*
NIA*
Ci NIA*
NIA*
NIA*
NIA*
Ci NIA*
NIA*
NIA*
NIA*
Ci NIA*
NIA*
NIA*
NIA*
Ci NIA*
NIA*
NIA*
NIA*
Ci NIA*
NIA*
NIA*
NIA*
Ci NIA*
NIA*
NIA*
NIA*
Ci NIA*
NIA*
NIA*
NIA*
Ci NIA*
NIA*
N/A*
NIA*
Ci NIA*
NIA*
NIA*
NIA*
Ci NIA*
NIA*
NIA*
NIA*
Ci NIA*
NIA*
NIA*
NIA*
Ci NIA*
NIA*
NIA*
NIA*
Ci NIA*
NIA*
N/A*
NIA*
Ci NIA*
NIA*
N/A*
N/A*
Ci NIA*
NIA*
NIA*
NIA*
Ci NIA*
NIA*
N/A*
NIA*
Ci NIA*
NIA*
NIA*
NIA*
There are no liquid effluents associated with the Haddam Neck Independent Spent Fuel Storage Installation (ISFSI)
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
N/A*
N/A*
NIA*
NIA*
NIA*
CY 2017 Annual RER Report Page 10 of 15
Table 3 HADDAM NECK ISFSI Effluent and Waste Disposal Annual Report First Half 2017 Low Level Waste Shipments
~-
- 1_'
Volume,*:.
~esl~,.FIiter-. and *1:vaporatc)r ~ojtQms Waste Class Solidifying Aaent ft3 m3 A
0 0
B 0
0 C
0 0
All 0
0 Major radionuclides for above data:
DI)' Active W*s~,
- volume.
Waste Class Solidifying Aaent ft3 m3 A
0 0
B 0
0 C
0 0
All 0
0 Major radionuclide& for above data:
' lrradia*d*.components.. *
'Volume Waste Class Solidifying Aaent ft3 m3 A
0 0
B 0
0 C
0 0
All 0
0 Maior radionuclldes for above data:
- Other'waste
...volume*.**
Waste Class Solidifying Agent ft3 m3 A
0 0
B 0
0 C
0 0
All 0
0 Maior radionuclides for above data:
CY 2017 Annual RER Report
- -.curies Ship~~.
Curies 0
0 0
0 Cllries -~hip1>9d Curies 0
0 0
0
'.C.~riet1 Shlp~d Curies 0
.o 0
0
...Quries_ S~lpi>e,d **
Curies 0
0 0
0 Page 11 of 15
Table3A HADDAM NECK ISFSI Effluent and Waste Disposal Annual Report Second Half 2017 Low Level Waste Shipments Reslris~
- FllterJ. and 'l::v~porator.Bottoms
- Volume*..
Waste Class Solidlfvlna Aaent ft3 m3 A
0 0
B 0
0 C
0 0
All 0
0 Major radlonuclldes for above data:
~ry-Actlve wa*te *.
- Volume Waste Class Solidlfvlna Aaent ft3 m3 A
0 0
B 0
0 C
0 0
All 0
0 Major radionuclides for above data:
Irradiated-Components
.Vollil'i'.18 Waste Class Solidlfvina Aaent ft3 m3 A
0 0
B 0
0 C
0 0
All 0
0
. Malor radlonuclldes for above data:
other*waste.
,~. '.
'.Volum*e
'*"'/
Waste Class Solidlfvlna Aaent ft3 m3 A
0 0
B 0
0 C
0 0
All 0
0 Major radionuclldes for above data:
CY 2017 Annual RER Report
. Cur,les.Shlp~d..
Curies 0
0 0
0
- Curi-. $hipl)8.d
- Curies 0
0 0
0 Curles Shlp1>9d Curies 0
0 0
0
- t:llries :*S~1-.,pe~.
Curies 0
0 0
0 Page 12 of 15
Appendix A Radiation Dose Assessment There were no gaseous or liquid effluent releases in 2017. 'Therefore, an assessment of radiation doses to the most likely exposed member(s) of the public to show compliance with 40CFR 190 or 10CFR72.104 from effluents was not required.
CY 2017 Annual RER Report Page 13 of 15
AppendixB Abnormal Releases There were no abnormal releases of radioactive materials from the site in 2017.
CY 2017 Annual RER Report Page 14 of 15
AppendixC Off-site Dose Calculation Manual Changes There were no changes to the Off-site Dose Calculation Manual in 2017.