ML18094B424

From kanterella
Jump to navigation Jump to search
Technical Evaluation Rept on Second 10-Yr Interval Inservice Insp Program Plan:Salem Generating Station,Unit 1
ML18094B424
Person / Time
Site: Salem 
Issue date: 11/30/1989
From: Beth Brown, Mudlin J
EG&G IDAHO, INC.
To:
NRC
Shared Package
ML18094B422 List:
References
CON-FIN-D-6022 EGG-MS-8435, NUDOCS 9004260042
Download: ML18094B424 (1)


Text

Idaho National Engineering Laboratory Managed bv the us.

Department of Energy Work performed under DOE Contract No. DE-AC07-761D015'10 EGG-MS-8435 November 1989 ENCLOSURE 2 TECHNICAL EVALUATION REPORT TECHNICAL EVALUATION REPORT ON THE SECOND 10-YEAR INTERVAL INSERVICE INSPECTION PROGRAM PLAN:

PUBLIC SERVICE ELECTRIC ANO GAS COMPANY 9 SALEM GENERATING STATION, UNIT 1, DOCKET NUMBER 50-272 B. W. Brown J, 0. Mudlin Prepared for the U.S. NUCLEAR REGULATORY COMMISSION