DESIGN FEATURES DESIGN PRESSURE AND TEMPERATURE 5.2.2 The reactor containment building is designed and shall be maintained for a maximum internal pressure of 47 psig and an air temperature of 271°F.
5.3 REACTOR CORE FUEL ASSEMBLIES 5.3.1 The reactor core shall contain 193 fuel assemblies with each fuel assembly normally containing 264 fuel rods clad with Ziracloy-4 except that limited substitution of fuel rods by filler rods consisting of Ziracloy-4 or stainless steel or by vacancies may be made if justified by a cycle specific reload analysis.
Each fuel rod shall have a nominal active fuel length of 143.7 inches.
The initial core loading shall have a maximum enrichment of 3.35 weight percent U-235.
Reload fuel shall be similar in physical design to the core loading and shall have a maximum enrichment of 4.05 weight percent U-235.
CONTROL ROD ASSEMBLIES 5.3.2 The reactor core shall contain 53 full length and no part length control rod assemblies.
The full length control rod assemblies shall contain a nominal 142 inches of absorber material.
The nominal values of absorber material shall be 80 percent silver, 15 percent indium and 5 percent cadmium.
All control rods shall be clad with stainless steel tubing.
- 5. 4 REACTOR COO LANT SYSTEM DESIGN FEATURE AND TEMPERATURE 5.4.1 The reactor coolant system is designed and shall be maintained:
SA LEM -
UN IT 1 5-4 Amendment No.
-~..., ~"
DESIGN FEATURES DESIGN PRESSURE AND TEMPERATURE 5.2.2 The reactor containment building is designed and shall be maintained for a maximum internal pressure of 47 psig and an air temperature of 271°F.
5.3 REACTOR CORE FUEL ASSEMBLIES 5.3.1 The reactor core shall contain 193 fuel assemblies with each fuel assembly normally containing 264 fuel rods clad with Ziracloy-4 except that limited substitution of fuel rods by filler rods consisting of Ziracloy-4 or stainless steel or by vacancies may be made if justified by a cycle specific reload analysis.
Each fuel rod shall have a nominal active fuel length of 143.7 inches.
The initial core loading shall have a maximum enrichment of 3.55 weight percent U-235.
Reload fuel shall be similar in physical design to the core loading and shall have a maximum enrichment of 4.05 weight percent U-235.
CONTROL ROD ASSEMBLIES 5.3.2 The reactor core shall contain 53 full length and no part length control rod assemblies.
The full length control rod assemblies shall contain a nominal 142 inches of absorber material.
The nominal values of absorber material shall be 80 percent silver, 15 percent indium and 5 percent cadmium.
All control rods shall be clad with stainless steel tubing.
5.4 REACTOR COOLANT SYSTEM DESIGN FEATURE AND TEMPERATURE 5.4.1 The reactor coolant system is designed and shall be maintained:
VOLUME
- a.
In accordance with the code requirement specified in Section 4.1 of the FSAR, with allowance for normal degradation pursuant to the applicable Surveillance Req~irements,
- b.
For a pressure of 2485 psig, and
- c.
For a temperature of 650°F, except for the pressurizer which is 680°F.
5.4.2 The total water and steam volume of the reactor coolant system is 12,811 + 100 cubic feet at a nominal Tavg of 581.0°F.
SA LEM -