ll:S IGN FEATURES OCSIGN PRESSURE AND TEMPERATURE 5.2.2 The reactor containment building is designed and shall be maintained for a maximum internal pressure of 47 psig and an air temperature of 271°F.

5.3 REACTOR CORE FUEL ASSEMBLIES 5.3.1 The reactor core shall contain 193 fuel assemblies with each fuel assembly containing 264 fuel rods clad with Zircaloy-4.

Each fuel rod shall have a nominal active fuel length of 143.7 inches.

The initial core loading shall have a maximum enrichment of 3.35 weight percent U-235.

Reload fuel shall be similar in physical design to the initial core loading and shall have a maximum enrichment of 4.05 weight percent U-235.

CONTROL ROD ASSEMBLIES 5.3.2 The reactor core shall contain 53 full length and no part length control rod assemblies.

The full length control rod assemblies shall *contain a nominal 142 inches of absorber material. The nominal values of absorber material shall be 80 percent silver, 15 percent indium and 5 percent cadium.

All control rods shall be clad with stainless steel tubing.

5.4 REACTOR COOLANT SYSTEM DESIGN PRESSURE AND TEMPERATURE 5.4.1 The reactor coolant system is designed and shall be maintained:

8610100230 861003 PDR ADOCK 05000272 P

PDR SA LEM -

UN IT 1 5-4 Amendment No.

r

.... 'I-..-,

~ I

, r

!:ES IGN FEATURES l:ESIGN PRESSURE AND TEMPERATURE 5.2.2 The reactor containment building is designed and shall be maintained for a maximum internal pressure of 47 psig and an air temperature of 271°F.

5.3 REACTOR CORE FUEL ASSEMBLIES 5.3.1 The reactor core shall contain 193 fuel assemblies with each fuel assembly containing 264 fuel rods clad with Zircaloy-4.

Each fuel rod shall have a nominal active fuel length of 143.7 inches.

The initial core loading t

shall have a maximum enrichment of 3.35 weight percent U-235.

Reload fuel shall be similar in physical design to the initial core loading and shall have a maximum enrichment of 4.05 weight percent U-235.

CONTROL ROD ASSEMBLIES 5.3.2 The reactor core shall contain 53 full length and no part length control rod assemblies. The full length control rod assemblies shall contain a nominal 142 inches of absorber material. The nominal values of absorber material shall be 80 perent silver, 15 percent indium and 5 percent cadium.

All control rods shall be clad with stainless steel tubing.

5.4 REACTOR COOLANT SYSTEM DESIGN PRESSURE AND TEMPERATURE 5.4.1 The reactor coolant system is designed and shall be maintained:

VOLUME

a.

In accordance with the code requirements specified in Section 4.1 of the FSAR, with allowance for normal degradation pursuant to the applicable Surveillance Requirements,

b.

For a pressure of 2485 psig, and

c. For a temperature of 650°F, except for the pressurizer which is 680°F.

5.4.2 The total water and steam volume.of the reactor coolant system is 12,811 + 100 cubic feet at a nominal Tavg of 581.0°F

  • SA LEM - UN IT 2 5"-4 Amendment No.

J