Proposed Tech Specs Re Containment Isolation Valves
ML18092A920
Person / Time
Site: Salem  PSEG icon.png
Issue date: 11/27/1985
From:
Public Service Enterprise Group
To:
Shared Package
ML18092A919 List:
References
NUDOCS 8512110248
Download: ML18092A920 (15)


Text

CONTAINMENT SYSTEMS CONTAINMENT ISOLATION VALVES LIMITING CONDITION FOR OPERATION 3.6.3.1 The containl'lent isolation valves specified in Table 3.6-1 shall be either OPERABLE with isolation times as shown in Table 3.6-1 or administratively maintained closed.

APPLICABILITY:

MODES 1, 2, 3 and 4 ACTION:

Hith one or rrore of the isolation valve(s) specified in Table 3.6-1 inoperable in the open position, either:

a.

Maintain at least one isolation valve.OPERABLE in each affected penetration that is open and restore the inoperable valve(s) to OPERABLE status within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />, or

b.

Isolate each affected penetration within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> by use of at least one deactivated automatic_ valve secured in the isolation position, or

c.

Isolate each affected penetration within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> by use of at least one closed manual valve, or a blank flange, or

d.

Be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTffi5WN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

SURVEILLANCE REQJIREMENTS 4.6.3~1.1 The isolation.valves specified in Table 3.6-1 shall be demonstrated OPERABLE prior to returning the valve to service after maintenance, repair, or replacement work is performed on the valve or its associated actuator, control or power circuit by perforl'lance of a cycling test and verification of isolation time.

SALEM - UN IT 1 3/4 6-12

~~~~~~-=::;:--~~~.,

8512110248 851127 II PDR ADOCK 05000272 p

PDR

Ul

~

t'i l::t:l

~

I c VALVE* NUMBER z

H 8

A. PHASE 11A II ISOLATION I-'

1. 1 PR 17*
2.

1 PR 18*

3.

1 NT 25*

4.

1 WR 80*

5.

1 CV 3

6.

1 CV 4

7.

1 CV 5

8. 1 CV 7
9.

1 CV 68##

10.

1 CV 69##

11.

1 CV 284 w

12.

1 CV 116

'h.,.

13.

1 cc 215 O'I

14. 1 cc 113 I
15.

1 WL 96*

I-'

16.

1 WL 97*

17.

1 WL 98*

18.

1 WL 99*

19.

1 WL 108*

20.

1 WL 12*

21.

1 WL 13*

22.

1 NT 32*

23.

1 SJ 123*

24.

1 SJ 60*

25.

1 SJ 53*

26.

1 SS 103*

27.

1 SS 27*

28.

1 SS 104*

29.

1 SS 33*

TABLE 3.6-1 CONTAINMENT 1SOLATION VALVES FUNCTION Pressurizer Relief Tk.-Gas Analyzer Conn.

Pressurizer Relief Tk.-Gas Analyzer Conn.

Pressurizer Relief Tk.-N2 Connection*

Pressurizer Relief Tk.-Primary Water Conn.

CVCS - Letdown Line CVCS - Letdown Line CVCS - Letdown Line CVCS - Letdown Line CVCS - Charging line CVCS - Charging Line eves - RCP Seals CVCS - RCP Seals Comp. Cooling to Excess Letdown Hx Comp. Cooling to Excess Letdown Hx RC Drain Tk.

Gas. Analyzer Conn.

RC Drain Tk. - Gas Analyzer Conn.

RC Drain Tk. - Vent Header Conn.

RC Drain Tk. - Vent Header Conn.

RC Drain. Tk. - N2 Connection RC Drain Tank Pumps RC Drain Tank Pumps Accumulator N2 Connection SI Test Line SI Test Line SI Test Line Accumulator Sampling Accumulator Sampling RC Sampling RC Sampling ISOLATION TIME (Seconds)

,<lOSec.

<10 Sec.

< 10 Sec~

< 10 Sec.

<1,1 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

. <10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

(IO Se,c.

< *10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

Ul

~

tc:l s:

I c z H

1-3 A.

B.

c.

VALVE NUMBER PHASE 11A II ISOLATION (Cont<l.)

30.

1 SS 107*

31.

1 SS 49*

32.

1 SS 110*

33.

1 SS 64*

34.

1 vc 7

35.

1 vc 8

36.

1 vc 11

37.

1 vc 12

38. 11 CA 330
39. 12 CA 330
40.

1 DR 29

41.

1 ~JL 16

42.

1 WL 17

43.

1 FP 147*

PHASE 11B II ISOLATION

1.

1 cc 118tt

2.

1 cc 117tt

3.

1 cc 187

4.

1 cc 136

5.

1 cc 190

6.

1 cc 131 MAIN STEAM ISOLATION

1. 11 MS 7#
2. 12 MS 7#
3. 13 MS 7#
4. 13 MS 7#
5. 13 MS 7#
6. 12 MS 18#
7. 13 MS 18#
8. 14 MS 18#

TABLt 3.6-1 (Contd.)

CONTAINMENT ISOLATION VALVES FUNCTION Pressurizer Liquid Sampling Pressurizer Liqui~ Sampling Pressurizer Steam Sampling Pressurizer Steam Sampling Containment Radiation Sampling Containment Radiation Sampling Containment Radiation Sampling Containment Radiation Sampling Instrument. Air Supply Instrument Air Supply Demineralized Water Sup~ly Containment Sump Discharge Containment Sump Discharge Fire Protection System Component Cooling to Component Cool i n*g to Component Cooling to Component Cooling to Component Cooling to.

Component Cooling to Main Steam Drain

RCP RCP RCP RCP RCP RCP ISOLATION TIME (Seconds)

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

.< 10 Sec.

A

< 10 Sec.

<10 Sec.

< 10 Sec.

< 10 Sec.

< 10 sec.

<10 Sec.

< 10 Sec.

<10 Sec.

< 10 Sec.

< 10 Sec.

(10 Sec.

< 10 Sec.

(10 Sec.

< 10 Sec.*

<10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

e I

c z H

1-3 w

O'I I

I-'

Ul VALVE NUMBER D. FEEDWATER ISOLATION

1. 11 BF 19#
2. 12 BF 19#
3. 13 BF 19#
4. 14 BF 19#
5. 11 BF 40#
6. 12 BF 40#
7. 13 BF 40#
8. 14 BF 40#

E. STEAM GENERATOR BLOWDOWN

1. 11 GB 4#
2. 12 GB 4#
3. 13 GB 4#
4. 14 GB 4#
5. 11 SS 94#
6. 12 SS 94#
7. 13 SS 94#
8. 14 SS 94#

F.

CONTAINMENT PURGE Main Main Main Main Main Main Main Main ISOLATION TABLE 3.6-1 '(Contd.)

CONTAINMENT ISOLATION VALVES FUNCTI'ON Feed\\-Jater I s0 lat ion Feedwater I so 1 at ion Feedwater I so 1 at ion Feedwater Isolation Feeclwater *1 sol at ion Feedwater Isolation Feedwater I sol at ion Feedwater Isolation

  • steam Generator Blowaown Steam Generator Blowdown Stearn Generator Blowclown Stearn Generator Blowdown SG Blowdown Sampling SG Blowdown Sampling SG Blowdown Sampling SG Blowdown Samplyng AND PRESSURE-VACUUM RELIEF
1.

1 vc 1 Purge Supply

2.

1 vc 2 Purge Supply

3.

1 vc 3 Purge Exhaust 4.*

1 vc 4 Purge Exhaust

5.

1 vc 5*

Pressure-Vacuum Relief

6.

1 vc 6*

Pressure-Vacuum Relief ISOLATION TIME (Seconcts)

< 8 Sec.

-< 8 Sec.

-< 8 Sec.

< 8 Sec.

-< 8 Sec.

-< 8 Sec.

< 8 Sec.

-< 8 Sec-.

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 2 Sec.

-< 2 Sec.

< 2 Sec.

< 2 Sec.

< 2 Sec.

< 2 Sec.

(/)

TABLE 3.6-1 (Contd.)

t::'

t'i CONTAINMENT ISOLATION VALVES t:Ij

3::

c:: z VALVE NUMBER FUNCTION I SOLA TI ON TI ME (Seconds)

H 8

G. MANUAL I-'

1. 1 SS 900#

Pressurizer Dead-Weight Calibrator Not Applicable

2.

1 SS 901#

Pressurizer Dead-Weight Calibrator Not Applicable

3. 11 CV 98#

eves - RCP seals Not Applicable -

4. 12 CV 98#

CVCS - RCP Seals Not Applicable

5. 13 CV 98#

eves - RCP Seals Not Applicable

6. 14 CV 98#

eves - RCP Seals Not Applicable

7.

1 SJ 71#

CVCS Flushing Connection Not Applicable

8.

1 SA 118 Compressed Air Supply

  • Not Applicable
9.

1 WL 190 Refueling Canal Supply Not Applicable

10.

1 SF 36 Refueling Canal Supply Not Applicable w

11.

1 WL 191 Refueling Canal Discharge Not Applicable

12.

1 SF 22 Refueling Canal Discharge Not Applicable ii':>

13.

1 vc 9*

Containment Radiation Sampling Not Applicable O"I

14.

1 vc 10*

Containment Radiation Sampling Not Applicable I

I-'

15.

1 vc 13*

Containment Radiation Sampling Not Applicable O"I

16.

1 vc 14*

Containment Radiation Sampling Not Applicable

17.

Fuel Transfer Tube Not Applicable

18.

1 cs 900 Containment Instrumentation Fi 11 Conn.

Not Applicable

19.

1 cs 901 Containment Instrumentation Fil 1 Conn.

Not Applicable

20.

1 cs 902 Containment Instrumentation Fill Conn.

Not Applicable e

21.

1 cs 903 Containment Instrumentation Fil 1 Conn.

Not Applicable

22.

1 SA 262 Containment Pressure Test Conn.

Not Applicable

23.

1 SA 2n4 Co n t a i n me n t Pres s u re Te st Co n n *,

Not Applicable

24.

1 SA 265 Containment Pressure Test Conn.

Not Applicable

25.

1 SA 267 Containment Pressure Test Conn.

Not Applicable

26.

1 SA 268 Containment Pressure Test Conn.

Not Appl i cah 1 e

27.

1 SA 270 Containment Pressure Test Conn.

Not Applicable

28.

1 CA 1714 Containment Air Lock Instrument Conn.

Not Applicable

29.

1 CA 1715 Containment Air* Lock Instrument Conn.

Not Applicable

TABLE 3.6-1 (Contd.)

[fl

~

CONTAINMENT ISOLATION VALVES t"i l:rj

~

VALVE NUMBER FUNCTION ISOLATION TIME (Seconds) d z G. MANUAL H

1-3 f-'

30. 11 SS 181*

Post LOCA Sampling Not Applicable

31. 11 SS 182*

Post LOCA Sampling Not Applicable

32. 11 SS 188*

Post LOCA Sampling Not Applicable

33. 11 SS 189*

Fbst LOCA Sampling Not Applicable

34. 13 SS 181*

Post LOCA Sampling Not Applicable

35. 13 SS 182*

Post LOCA Sampling Not Appl i cable

36. 13 SS 184*

Post LOCA Sampling Not Applicable

37. 13 SS 185*

Post LOCA Sampling Not Appl i cab l e

38. 11 vc 17*

Post LOCA Sampling Not Applicable

39. 11 vc 18*

Post LOCA Sampling No t Appl i cab l e

40. 11 vc 19*

Post LOCA Sampling Not Applicable w

41. 11 SF 20*

Post LOCA Sampling Not Applicable

42. 12 vc 17*

Post LOCA Safllpling Not Applicable CJ'\\

43. 12 vc 18*

Post LOCA Sampling Not Appl i cahl e I

44. 12 vc 19*
  • Post LOCA Sampling Not Applicable f-'

.....J

45. 12 vc 20*

Post LOCA Sampling Not Appl i cab l e

46. 11 cs 2t Containment Spray Not Applicable
47. 12 cs 2t Containme~t Spray Not Applicable H.

CHECK I --

1.

1 CV 74 CVCS-Charging Line Not Applicable

2.

1 CV 296 CVCS-RCP Seals Not Applicable 3 *. 1 cc 119 Component Cooling to RCP Not Applicable

4.

1 cc 186 Component Cooling to RCP Not Applicable

5.

1 cc 208 Component Cooling to RCP Not Applicable

6. 11 cs 48 Containment Spray Not Applicable
7. 12 cs 48 Containment Spray No t App l i ca bl e
8.

1 DR 30 Demineralized Water System Not Applicable

9.

1 FP 148 Fire Protection System Not Applicable

10.

1 NT 26 Pressurizer Relief Tk.--Nitrogen Conn.

Not Applicable

11.

1 NT 34 Accumulator Nitrogen Supply Not Applicable

12.

1 SA 119 Compressed Air Supply Not Applicable

TABLE 3.6-1 (Contd.)

CONTAINMENT ISOLATION VALVES VALVE NUMBER FUNCTION ISOLATION TIME (Seconds)

H. CHECK (Contd.)

13.

1 WR 81

14. 11 CA 360
15. 12 CA 360 Pressurizer Relief Tk.-Primary Water Conn.

Instrument Air Supply Instrument Air

  • May be opened on an intermittent basis under administrative control.
  1. Not subject to Type C leakage tests.
    1. Either valve 1 CV 68 or 1 CV 69 must be OPERABLE.

tNormally closed rmtor operated containment isolation valve. Valve opens on Phase B isolation ttEither Valve 1CC117 or 1CC118 must be OPERABLE.

Not Applicable Not Applicable Not Applicable l

REVISED PAGES -

UNIT NO. 2

CONTAINMENT*SYSTEMS CONTAINMENT ISOLATION VALV-ES.

LIMITING CONDITION FOR OPERATION 3.6.3 The containment isolation valves specified in Table 3.6-1 shall be either OPERABLE with isolation times as shown in Table 3.6-1 or administratively maintained closed.

APPLICABILITY:

MODES 1, 2, 3 and 4 ACTION:

With one or more of the isolation valve(s) specified in Table 3.6-1 inoperable in the open position, either:

a.

Maintain at least one isolation valve OPERABLE in each affected penetration that is open and restore the inoperable valve(s) to OPERABLE status within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />, or

b.

Isolate each affected penetration within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> by use of at least one deactivated automatic valve secured in the isolation position, or

c.

Isolate each affected penetration within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> by use of at least one closed manual valve, or a blank flange, or

d.

Be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDO~ within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

SURVEILLANCE REQJIREMENTS

.4.6.3.1 The isolation val'ves specified in "'Fable 3.6-1 shall be demonstrated OPERABLE prior to returning the valve to service after maintenance, repair, or replacement work is performed on the valve or its associ a't;ed actuator, control or power circuit by performance of a cycling test and verificatio*n of isolation time.

SALEM - UN IT 2 3/4 6-14

CJ)

~

1:-1 tx:l

s:

VALVE NUMBER c::

A. PHASE 11A 11 ISOLATION z

H f-:3

1. 2 PR 17*

N

2.

2 PR 18*

3.

2 NT 25*

4.

2 WR 80*

5.

2 CV 3

6.

2 CV 4

7.

2 CV 5

8. 2 CV 7
9.

2 CV 68##

10.

2 CV 69##

11.

2 CV 284

12.

2 CV 116 w

13.

2 cc 215

14.

2 cc 113

°'

15.

2 WL 96*

I

16.

2* WL 97*

I-'

17.

2 WL 98*

°'

18.

2 WL 99*

19.

2 WL 108*

20.

2 WL 12*

21.

2 WL 13*

22.

2 NT 32*

23.

2 SJ 123*

24.

2 SJ 60*

25.

2 SJ 53*

26.

2 SS 103*

27.

2 SS 27*

28.

2 SS 104*

29.

2 SS 33*

TABLE 3~6-1 CONTAINMENT ISOLATION VALVES FUNCTION Pressurizer Relief Tk.-Gas Analyzer Conn.

Pressurizer Relief Tk.-Gas Analyzer Conn.

Pressurizer Relief Tk.-N2 Connection Pressurizer Relief Tk. -Primary Water Conn.

CVCS - Let<lown Line CVCS - Let<lown Line CVCS - Letdown Line CVCS - Letdown Line CVCS - Charging Line CVCS - Charging Line CVCS - RCP Seals eves - RC P Seals Comp. Cooling to Excess Letdown Hx Comp. Coo 1 i ng to Excess Letdown Hx RC Drain Tk. - Gas Analyzer Conn.

RC Drain Tk. - Gas Analyzer Conn.

RC Drain Tk. - Vent HeaCler Conn.

RC Drain Tk. - Vent Header Conn.

RC Drain Tk. - N2 Connection RC Drain Tank Pumps RC Drain Tank Pumps Accumulator N2 Connection*

SI Test Line SI Test Line SI Test Line Accumulator Sampling Accumulator Sampling RC Sampling RC.Sampling ISOLATION TIME (Seconds)

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 10 sec.

<10 Sec.

< 10 Sec.

<.io Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

<10 Sec.

< 10 Sec.

<10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

<10 Sec.

. i

VALVE NUMBER A. PHASE "A" ISOLATION

30.

2 SS 107*

31.

2 SS 49*

32.

2 SS 110*

33.

2 SS 64*

34.

2 vc 7

35.

2 vc 8

36.

2 vc 11

37.

2 vc 12

38. 21 CA 330
39. 22 CA 330
40.

2 DR 29

41.

2 WL 16

42.

2 WL 17

43.

2 FP 147*

B. PHASE "B II ISOLATION

1.

2 cc 118tt

2.

2 cc 117tt

3.

2 cc 187

4.

2 cc 136

5.

2 cc 190

6.

2 cc 131

c. MAIN STEAM ISOLATION
1. 21 MS 7#
2. 22 MS 7#
3. 23 MS 7#
4. 23 MS 7#
5. 23 MS 7#
6. 22 MS 18#
7. 23 MS 18#
8. 24 MS 18#

(Contd.)

TABLE 3.6-1 (Contd.)

CONTAINMENT ISOLATION VALVES FUNCTION Pressurizer Liquid Sampling Pressurizer Liquid Sampling Pressurizer Steam Sampli°ng Pressurizer Steam Sampling Containment Radiation Sampling Containment Radiation Sampling Containment Radiation Sampling Containment Radiation Sampling Instrument Air Supply Instrument Air Supply Demineralized Water Supply Containment Sump Discharge Containment Sump Discharge Fire Protection System Component Cooiing Component Cooling Compbnent Cooling Component Cooling Component Cooling Component Cooling Main Steam Drain Main Steam Drain Main Steam Drain Main Steam Drain Main Steam Bypass Main Stea~ Bypass Main Steam Bypass Main Steam Bypass to RCP to RCP to RCP to RCP to. RCP to RCP ISOLATION TIME (Seconds)

< 10 See.

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

<10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 10.Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

<10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

., ]

e

~

H t-3 N

O'I I

I-'

-...)

VALVE NUMBER D. FEEDWATER ISOLATION

1. 21 BF 19#
2. 22 BF 19#
3. 23 BF 19#
4. 24 BF 19#
5. 21 BF 40#

6 *. 22 BF 40#

7. 23 BF 40#
8. 24 BF 40#

Main Main Main Main Main Main Main Main TARLE 3.6-1 {Contd.)

CONTAINMENT ISOLATION VALVES FUNCTION Feedwater I so 1 at ion Feedwater Isolation Feedw.ater I sol at ion Feenwater Isolation Feedwater I sol at ion Feedwater I sol at ion Feedwater Isolation Feedwater Isolation E. STEAM GENERATOR BLOWDOWN ISOLATION

1. 21 GB 4#
2. 22 GB 4#

3.23GB4#

4. 24 GB 4#
5. 21 SS 94#
6. 22 SS 94#
7. 23 SS 94#
8. 24 SS 94#

F.

CONTAINMENT PURGE AND PRESSURE-VACUUM RELIEF

1.

2 vc 1

2.

2 vc 2

3.

2 vc 3

4.

2 vc 4

5.

2 vc 5*

6.

2 vc 6*

Steam Generator Blowdown Steam Generator Blowdown Steam Generator Blowdown Steam Generator Blowdown SG Blowdown Sampling SG Blowdown Sampling SG Blowdown Sampling SG Blowdown Sampling Purge Supply Purge Supply Purge Exhaust*

Purge Exhaust Pressure-Vacuum Relief Pressure-Vacuum Relief ISOLATION TIME (Seconds)

< 5 Sec.

-< 5 Sec.

< 5 Sec.

-< 5 Sec.

< 5 Sec. :

< 5 Sec.

<* 5 Sec.

-< 5 Sec.

< lf) Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

< 10 Sec.

< Hl Sec.

< 10 Sec.

< 10 Sec.

< 2 Sec.

< 2 Sec.

< 2 Sec.

< 2 Sec.

-< 2 Sec.

< 2 Sec.

e

(/)

~

t;i tr::! :s:

d.z G.

H 8

w I

t--'

OJ VALVE NUMBER MANUAL

1.

2 SS 900#

2.

2 SS 901#

3. 21 CV 98#
4. 22 CV 98#
5. 23 CV 98#
6. 24 CV 98#
7.

2 SJ 71#

8.

2 SA 118

9.

2 WL 190

10.

2 SF 36

11.

2 WL 191

12.

2 SF 22

13.

2 vc 9*

14.

2 vc 10*

15.

2 vc 13*

16.

2 vc 14*

17.
18.

2 cs 900

19.

2 cs 901

20.

2 cs 902

21.

2 cs 903

22.

2 SA 262

23.

2 SA 264

24.

2 SA 265

25.

2 SA 267

26.

2 SA 208

27.

2 SA 270

28.

2 CA 1714

29.

2 CA 1715 TABL[ 3.6-1 (Contd.)

.CONTAINMENT ISOLATION VALVES FUNCTION Pressurizer Dead-Weight Calibrator Pressurizer Dearl-Weight Calibrator eves - RCP Seals CVCS - RCP Seals eves - RCP Seals eves - RCP Seals CVCS Flushing Connection Cornpresserl Air Supply Refueling Canal Supply Refueling Canal Supply Refueling Canal Discharge Refueling Canal* Discharge Containment Radiation Sampling Containment ~adiation Sampling Containment Rarliation Sampling Containment Radiation Sampling Fuel Transfer Tube Containment Instrumentation Fill Conn.

Containment Instrumentation Fill Conn.

Containment Instrumentation Fill Conn.

Containment Instrumentation Fill Conn.

Containment Pressure Test Conn.

Containment Pressure Test Conn.

Containment Pressure Test Conn *.

Containment Pressure Test Conn.

Containment Pressure Test Conn.

Containment Pressure Test Conn.

Containment Air Lock Instrument Conn.

Containrnent Air Lock Instrument Conn.

ISOLATION TIME (Seconds)

Not Applicable Not Applicahle Not Applicable Not Applicable Not Applicable Not Applicable Not Applicable Not Applicable Not Applicable*

Not Applicahle Not Applicable Not Applicable Not Applicable Not Applicable NO't Applicable Not Applicable Not Applicable Not Applicahle Not Applicable Not Applicable Not Appl i cable Not Applical>le Not Appl i cahl e Not Applicable Not Applicable Not Applicable Not Applicable Not Applicable Not Applicable

'11 TABLE 3.6-1 {Contd.)

(/)

CONTAINMENT ISOLATION VALVES

i:.-ti 1:7:1 :s:

VALVE NUMBER FUNCTION ISOLATION TIME (Seco.nds) c::: z G.

H MANUAL t-3 N

30. 21 SS 181*

Post LOCA Sampling Not ~pplicable

31. 21 SS 182*

Post LOCA Sampling Not Applicable

32. 21 SS 188*

Post LOCA Sampling Not Applicable e

33. 21 SS 189*

Post LOCA Sampling Not Applicable

34. 23 SS 181*

Post LOCA Sampling Not Applicable

35. 23 SS 182*

Post LOCA Sampling Not Applicable

36. 23 SS 184*

Post LOCA Sampling Not Applicable

37. 23 SS 185*

Post LOCA Sampling Not Applicable

38. 21 vc 17*

Post LOCA Sampling Not Applicable

39. 21 vc 18*

Post LOCA Sampling Not Applicable

40. 21 vc 19*

Post LOCA Sampling Not Applicable

41. 21 SF 20*

Post LOCA Sampling Not Applicable

42. 22 vc 1°7*

Post LOCA Sampling Not Applicable*

w

43. 22 vc 18*
  • Post LOCA Sampling Not Applicable
44. 22 vc 19*

Post LOCA Sampling Not Applicable

0)
45. 22 vc 20*

Post LOCA Sampling Not Applicable I

46. 21 cs 2t Containment Spray Not Applicable I-'

w

47. 22 cs 2t Containment Spray Not Applicable H.

CHECK

1. 2 CV 74 CVCS-Charging Line Not Applicable
2.

2 CV 296 CVCS-RCP Seals Not Applicable

3.

2 cc 119 Component Cooling to RCP Not Applicable

4.

2 cc 186 Component Cooling to RCP Not Applicable

5.

2 cc 208

  • component Coo 1 i ng to RCP Not Applicahle
6. 21 cs 48 Containment Spray Not Applicable
7. 22 cs 48 Contain111ent Spray Not Applicable
8.

2 DR 30 Demineralized Water System Not Applicahl~

9.

2 F P 148 Fire P'rotection System Not Applicable

10.

2 NT 26 Pressurizer Relief Tk. -Nitrogen Conn.

Not Applicable

11.

2 NT 34 Accumulator Nitrogen Supply Not Applicable

12.

2 SA 119 Compressed Air Supply Not Applicable

VALVE NUMBER TABLE 3.6-1 (Contd.)

CONTAINMENT ISOLATION VALVES FUNCTION ISOLATION TIME (Seconds) c:

~

H. CHECK (Contd.}

8 N

°'

I N

0

13.

2 WR 81

14. 21 CA 360
15. 22 CA 360 Pressurizer Relief Tk.-Primary Water Conn.

Instrument Air Supply Instrurrent Air

  • May be opened on an intermfttent basis under administrative control.
  1. Not subject to Type C leakage tests.

Not Applicable Not Applicable Not Applicable

    1. Either valve 1 CV 68 or 1 CV 69 must be OPERABLE.

tNormally closed rTDtor operated containment isolatio*n valve.

Valve opens on Phase B isolation ttEither Valve 1CC117 or 1CC118 must be OPERABLE.

'