ML18092A607

From kanterella
Jump to navigation Jump to search
Forwards Insp Rept 50-311/85-08 on 850321-22 & 25-29 & Notice of Violation
ML18092A607
Person / Time
Site: Salem 
Issue date: 04/25/1985
From: Collins S
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Corbin McNeil
Public Service Enterprise Group
Shared Package
ML18092A608 List:
References
NUDOCS 8505070202
Download: ML18092A607 (2)


See also: IR 05000311/1985008

Text

,,. '

  • ~

Docket No. 50-311

Public Service Electric and Gas Company

ATTN:

Mr. Corbin A. McNeill, Jr.

Vice President - Nuclear

P. 0. Box 236

Hancocks Bridge, New Jersey 08038

Gentlemen:

Subject:

Inspection No. 50-311/85-08

APR 2 5 1985

This refers to the special readiness assessment team inspection conducted by

Mr. Thomas Kenny and others of this office. The inspection, conducted March 21

and 22, and March 25-29, 1985 at the Salem Generating Station, Hancocks Bridge,

New Jersey, reviewed activities authorized by

NRC License No. DPR-75.

The

results of this inspection were discussed with Mr. J. M. Zupko, Jr., and other

members of your staff on March 29, 1985.

Areas examined during this inspection are described in the NRC Region I Inspec-

tion Report which is enclosed with this letter.

Within these areas, the in-

spection consisted of selective examinations of procedures and representative

records, interviews with personnel, examinations of work completed on modifica-

tions, and observations by the inspectors.

Based on the results of this inspection, it appears that one of your activities

was not in full compliance with NRC requirements, as set forth in the Notice of

Violation, enclosed herewith as Appendix A.

The violation has been categorized

by severity level in accordance with the revised NRC Enforcement Policy ( 10

CFR 2, Appendix C) published in the Federal Register Notice (49 FR 8583) dated

March 8, 1984.

You are required to respond to this letter and in preparing

your response, you should follow the instructions in Appendix A.

In addition to the violation, several other concerns were identified by the

inspectors. These concerns are described within the report and they appear to

be isolated instances. However, your attention to these concerns was adequate-

ly addressed by your staff while the inspection team was at the site.

The responses directed by this letter and the accompanying Notice are not sub-

ject to the clearance procedures of the Office of Management and Budget as

required by the Paperwork Reduction Act of 1980, PL-96-511:

8505070202 850425

PDR

ADOCK 05000311

G

PDR

OFFICIAL RECORD COPY

IR50-311/85-08 - 0001.0.0

04/04/85

APR 25 1985

Public Service Electric & Gas Co.

2

Your cooperation with us in this matter is appreciated.

Sincerely,

Samuel J. Collins, Chief

Projects Branch No. 2

Division of Reactor Projects

Enclosures:

1.

Appendix A, Notice of Violation

2.

NRC Region I Report 50-311/85-08

cc w/encls:

J/'R. L. Mittl, General Manager - Nuclear Assurance and Regulation

.......--J. M. Zupko, Jr., General Manager - Salem Operations

.z...----e. J. Johnson, General Manager Nuclear Quality Assurance

~E. A. Liden, Manager - Nuclear Licensing and Regulation

......---p. M. Krishna, Manager - Nuclear Review Board

.,,,,,,.-M. J. Wetterhahn, Esquire

~R. Fryling, Jr., Esquire

Public Document Room (PDR)

Local Public Document Room (LPDR)

NRC Resident Inspector

.VState of New Jersey

.,.,,,,,--J, H. Rodriquez, Public Advocate of the State of New Jersey

bee w/encls:

,ef'Region I Docket Room (with concurrences)

~Senior Operations Officer (w/o encl)

,._.-J,* Linville, Section Chief, DRP

I/' Di rector, DRS

v

Di rector, .DRSS

,,,_.--- H. R. Denton, D/NRR

Y- J. Taylor, D/OIE

,.;---H. Thompson, Jr., D/DL, NRR

......-S. Varga, ORB 1, NRR

......-J. Partlow, D/DP, IE

Jk, Jordan, D/DEPER, IE

W~I:DRP

. *:.,,__ Kenny /mj d

"xi RI:DRP

~¥Norrholm

@I:DRP

Co 11 ins

4/ /!J/85

I

    • -*

4{,1' /85

OFFICIAL RECORD COPY

IR50-311/85-08 - 0002.0.0

04/18/85