Docket No. 71-9342 Versa-Pac Safety Analysis Report Rev 10, March 2018 2-i CONTENTS 2

STRUCTURAL EVALUATION.................................................................................................2-1 2.1 Description of Structural Design...............................................................................2-1 2.1.1 Discussion.......................................................................................................................................... 2-1 2.1.2 Design Criteria................................................................................................................................. 2-2 2.1.3 Weights and Centers of Gravity.............................................................................................. 2-3 2.1.4 Identification of Codes and Standards for Package Design...................................... 2-4 2.2 Materials..........................................................................................................................2-4 2.2.1 Mechanical Properties of Materials...................................................................................... 2-4 2.2.2 Chemical, Galvanic Reactions and Other Reactions..................................................... 2-4 2.2.3 Effects of Radiation on Materials........................................................................................... 2-5 2.3 Fabrication and Examination.....................................................................................2-7 2.3.1 Fabrication........................................................................................................................................ 2-7 2.3.2 Examination...................................................................................................................................... 2-7 2.4 General Requirements for All Packages..................................................................2-7 2.4.1 Minimum Package Size............................................................................................................... 2-7 2.4.2 Tamper-Indicating Feature...................................................................................................... 2-7 2.4.3 Positive Closure.............................................................................................................................. 2-8 2.5 Lifting and Tie-down Devices.....................................................................................2-8 2.5.1 Lifting Devices................................................................................................................................. 2-8 2.5.2 Tie-down Devices.......................................................................................................................... 2-8 2.6 Normal Conditions of Transport (NCT)...................................................................2-8 2.6.1 Evaluation by Test......................................................................................................................... 2-8 2.6.2 Evaluation by Analysis................................................................................................................ 2-8 2.6.3 Heat....................................................................................................................................................... 2-9 2.6.4 Cold....................................................................................................................................................... 2-9 2.6.5 Reduced External Pressure................................................................................................... 2-10 2.6.6 Increased External Pressure................................................................................................. 2-10 2.6.7 Vibration.......................................................................................................................................... 2-10 2.6.8 Water Spray................................................................................................................................... 2-10 2.6.9 Free Drop........................................................................................................................................ 2-11 2.6.10 Corner Drop................................................................................................................................... 2-11 2.6.11 Compression.................................................................................................................................. 2-11 2.6.12 Penetration..................................................................................................................................... 2-12 2.7 Hypothetical Accident Conditions (HAC)............................................................. 2-12 2.7.1 Free Drop........................................................................................................................................ 2-13 2.7.2 Crush................................................................................................................................................. 2-16 2.7.3 Puncture.......................................................................................................................................... 2-16 2.7.4 Thermal............................................................................................................................................ 2-21 2.7.5 Immersion - Fissile Material................................................................................................ 2-22 2.7.6 Immersion - All Packages....................................................................................................... 2-22 2.7.7 Deep Water Immersion Test................................................................................................. 2-22 2.7.8 Summary of Damage................................................................................................................. 2-22

Docket No. 71-9342 Versa-Pac Safety Analysis Report Rev 10, March 2018 2-ii 2.8 Accident Conditions for Air Transport of Plutonium....................................... 2-23 2.9 Accident Conditions for Fissile Material Packages for Air Transport......... 2-23 2.10 Special Form................................................................................................................ 2-23 2.11 Fuel Rods...................................................................................................................... 2-23 2.12 References.................................................................................................................... 2-24 2.13 List of Appendices...................................................................................................... 2-25 2.13.1 Appendix 2.13.1 MACTEC Report on Material Compatibility.............................. 2-28 2.13.2 Appendix 2.13.2 Performance Test Report for the Versa-Pac............................. 2-30 2.13.3 Appendix 2.13.3 Excerpts from Safety Analysis Report for the Century Champion Type B Package Immersion Test...................................................................................... 2-31 2.13.4 Appendix 2.13.4 Test Report for the VP-55 Versa-Pac Shipping Package (Shallow Angle Drops).................................................................................................................................. 2-36 2.13.5 Appendix 2.13.5 NCT Versa-Pac Test Report for Compression & Penetration 2-37 2.13.6 Appendix 2.13.6 Performance Test Report for the VP-55 5-Inch Pipe Container............................................................................................................................................................. 2-38 2.13.7 Appendix 2.13.7 55 Gallon Versa-Pac Drop Test Deformation Measurement Report 2-39 TABLES TABLE 2-2. VERSA-PAC SHIPPING PACKAGE GROSS WEIGHTS......................................................................................... 2-4 TABLE 2-3. MECHANICAL PROPERTIES OF MATERIALS..................................................................................................... 2-6 TABLE 2-1 EVALUATION RESULTS.................................................................................................................................... 2-26 FIGURES FIGURE 2.13.3-1 CHAMPION PACKAGE ON TEST STAND............................................................................................... 2-32 FIGURE 2.13.3-2 CHAMPION PACKAGE DURING IMMERSION TESTING PHASE............................................................ 2-32 FIGURE 2.13.3-3 CHAMPION PACKAGE DURING IMMERSION TEST.............................................................................. 2-33 FIGURE 2.13.3-4 CHAMPION SAFETY ANALYSIS REPORT PAGE 15.............................................................................. 2-34 FIGURE 2.13.3-5 CHAMPION SAFETY ANALYSIS REPORT PAGE 16.............................................................................. 2-35

lJ DAHER-TLI Versa-Pac Safety Analysis Report 2

STRUCTURAL EVALUATION 2.1 Description of Structural Design 2.1.1 Discussion Docket No. 71-9342 Rev 10, March 2018 The Versa-Pac is a packaging designed for the shipment of radioactive materials containing less than or equal to the U-235 limits in Table 1-1 and Table 1-1A, including uranium oxides (UyOx),

uranium metal (U-metal), uranyl nitrate crystals (UNX), and other uranium compounds (e.g.,

Uranyl Fluorides and Uranyl Carbonates). The 1 S/2S cylinder contents of the package are limited to the quantities specified in Table 1-B and 1-C. The material may be pre-packaged in plastic, metal or Teflon containers.

The 55-gallon version of the Versa-Pac, the VP-55, consists of a 15" inner diameter by 25-7/8" inner height (IH) containment area centered within an insulated 55-gallon drum. Drawings of the VP-55 are provided in Appendix 1.4.1. The Versa-Pac design utilizes standard shop dimensions, tolerances, and structural materials as outlined in the drawings in Appendix 1.4.1 and the General Note Sheet found in Appendix 1.4.2. An illustration of the packaging is provided in Figure 1-1.

The overall nominal dimensions of the VP-55 are 23-1/16" Outside Diameter (OD) x 34-3/4" in height to the top of the outer drum bolt ring. The containment area is protected with a gasketed inner containment lid that is closed with twelve 1/2" bolts.

A polyurethane insulation plug is encapsulated in 16-gauge carbon steel welded onto the drum lid (see Appendix 1.4.3). The gasketed drum lid is closed with four1/2" bolts and a standard drum ring. A gasket at the drum lid's stiffening ring provides an additional barrier against water in-leakage.

The 55-gallon drum is strengthened with four longitudinal stiffeners fabricated from 1-1 /4" carbon steel square tubing equally spaced around the circumference of the drum. A 16-gauge outer liner and a 16-gauge inner liner provide additional insulated radial stiffness to the drum. The volume between the inner liner and the 10-gauge containment body is filled with ceramic fiber insulation (see Appendix 1.4.4).

The VP-55 5-inch pipe configuration results in at least double the contents of the VP-55, dependent on uranium-235 enrichment. This configuration includes a 5-inch pipe container located in the payload cavity that provides criticality control of the fissile contents.

The 5-inch pipe container will be secured in the containment for routine transport with a 'birdcage' type constraining device that provides no structural support; it is considered dunnage. The 5-inch pipe container also offers no structural support to the packaging; it is considered part of the contents. No credit is taken for the pipe container maintaining a specific position in the payload cavity under either NCT or HAC for the purposes of criticality control.

The 5-inch pipe container is based on the DOT-specification 2R container, as outlined in 49 CFR 178 § 178.360 [1]. [

] a,c A Hypothetical Accident Conditions (HAC) drop test series was performed on the 5-inch pipe container to verify its ability to maintain structural integrity and preserve the confinement of the 2-1

Docket No. 71-9342 Versa-Pac Safety Analysis Report Rev 10, March 2018 2-2 fissile materials. Only the HAC drop test series was performed as the HAC series bounds Normal Conditions of Transport (NCT) drop tests and analyses. The HAC drop test series is documented in a separate report located in Appendix 2.13.6.

The VP-110 consists of a 21 Inside Diameter (ID) x 32-3/4 Inside Height (IH) containment area centered within an insulated 110-gallon drum. Drawings of the VP-110 are provided in Appendix 1.4.1. The Versa-Pac design utilizes standard shop dimensions, tolerances and structural materials as outlined in the drawings in Appendix 1.4.1 and the General Note Sheet in Appendix 1.4.2. An illustration of the packaging is provided in Figure 1-1.

The overall nominal dimensions of the VP-110 are 30-7/16 Outside Diameter (OD) x 42-3/4 in height to the top of the outer drum bolt ring. The containment area is protected with a gasketed inner containment lid that is closed with twelve 1/2 bolts. A polyurethane insulation plug is encapsulated in 16-gauge carbon steel welded onto the drum lid (see Appendix 1.4.3). The gasketed drum lid is closed with eight 1/2 bolts and a standard drum ring. A gasket at the drum lids stiffening ring provides an additional barrier against water in-leakage.

The 110-gallon drum is strengthened with eight longitudinal stiffeners fabricated from 1-1/4 carbon steel square tubing equally spaced around the circumference of the drum. A 16-gauge outer liner and a 16-gauge inner liner provide additional insulated radial stiffness to the drum. The volume between the inner liner and the 10-gauge containment body is filled with ceramic fiber insulation (see Appendix 1.4.4).

The Versa-Pac design does not include lifting or tie down devices. Handling is accomplished using a standard drum handling equipment and/or a forklift. Shielding and pressure relief devices are not required for the Versa-Pac payloads. Plastic plugs, located on the inner liner and the acetate plug located on the exterior of the package are designed to vent any combustion products generated by the insulation under Hypothetical Accident Conditions. The containment boundary is the containment area, the containment area blind flange and containment flat gasket seal. The containment area is attached to the structural components of the Versa-Pac using 12 equally spaced 1/2 bolts through a 1/4 connection ring, a 1/2 thick fiberglass thermal break connected to the structural frame. Bolts are torqued and the bolt/nut connection spot-welded to prevent potential loss of the connection.

Performance of the package to the required regulations and design criteria is demonstrated through the analytical evaluations and prototype testing discussed in the remainder of this section.

The package performs as required to the applicable regulations, assuring safe transport of the payload. Table 2-1 provides a summary of the evaluations performed and their results.

2.1.2 Design Criteria The Versa-Pac was designed to meet all of the performance requirements of 10CFR71 [2] for fissile materials. The Versa-Pac is manufactured under a quality assurance program that meets the requirements of 10CFR71, Subpart H [3]. All welding is performed by qualified personnel in accordance with AWS D1.1 [4]. All inspections are conducted by personnel qualified under ASNT-TC-1A [5], and/or for visual inspection, certified as an AWS certified welding inspector or assistant.

The containment boundary is defined as the containment area, its seal and blind flange. The structural design criteria for the packaging under the Normal condition are:

Docket No. 71-9342 Versa-Pac Safety Analysis Report Rev 10, March 2018 2-3 The packaging is maintained within the allowable temperature, pressure and stress ranges as stated in each Section and Table 2-1; VP The package outer diameter and the height are essentially maintained at their nominal as-built dimensions; VP-110 - The package outer diameter and the height are essentially maintained at their nominal as-built dimensions; Positive closure is maintained during transport; Moderators are evaluated inside the payload vessel (criticality control requirement);

Chemical and galvanic reactions do not impair the function of the packaging within its 10-year design lifetime; The package is stackable and meets the applicable regulations; and Performance and design of the packaging meets other minimum regulatory requirements for licensure.

The design criteria under Hypothetical Accident Conditions are:

The packaging is maintained within the allowable temperature, pressure and stress ranges as stated in each Section and Table 2-1; VP The average OD of the packaging is maintained greater than 21.1 and the minimum height of the packaging is maintained greater than 33.6 under all conditions (criticality control requirement);

VP-110 - The average OD of the packaging is maintained greater than 28.5 and the minimum height of the packaging is maintained greater than 41.8 under all conditions (criticality control requirement);

Table 2-1 provides a summary of the structural evaluation, design criteria, and results of the evaluation.

2.1.3 Weights and Centers of Gravity The weight of each model of the Versa-Pac is provided in Table 2-2. The allowable payload weight of the VP-55 is 350 lb and the maximum gross weight of the VP-55 is 750 lb per the drop-test report listed in Appendix 2.13.7. The center of gravity of an empty VP-55 is located approximately 20 from the absolute base of the package along a vertical axis in the geometric center of the package. The center of gravity of a loaded package will shift downward by approximately 1. The center of gravity of an empty VP-110 is located at approximately 18.

Docket No. 71-9342 Versa-Pac Safety Analysis Report Rev 10, March 2018 2-4 Table 2-2. Versa-Pac Shipping Package Gross Weights 55-Gallon Version - Model No. VP-55 Component Weight (kg)

Weight (lb)

Versa-Pac Shipping Package (Nominal) 177 390 Maximum Payload 158 350 Maximum Gross Weight of Loaded Package 340 750 110-Gallon Version - Model No. VP-110 Component Weight (kg)

Weight (lb)

Versa-Pac Shipping Package (Nominal) 321 705 Maximum Payload 119 260 Maximum Gross Weight of Loaded Package 439 965 2.1.4 Identification of Codes and Standards for Package Design The Versa-Pac is a Type A fissile package based on the maximum U-235 payloads outlined in Table 1-1 and Table 1-1A. The 1S/2S UF6 cylinder contents are limited per the requirements in Tables 1-B and 1-C.

The Versa-Pac was designed to meet the requirements of 10CFR71 [2] and IAEA Regulations for the Safe Transport of Radioactive Material, SSR-6 [6].

Fabrication and the assembly of the Versa-Pac are conducted in accordance with Daher-TLI Quality Assurance Program [7] and normal shop Standard Operating Procedures. Welding shall be performed by qualified personnel using approved procedures in accordance with AWS D1.1

[4].

Testing and inspection of the Versa-Pac Shipping Packages will be conducted in accordance with Standard Operating Procedures in compliance with the appropriate code, such as ASNT, ASME and AWS.

Maintenance and use of the Versa-Pac Shipping Package shall be conducted in accordance with Section 7.0, Operating Procedures and Section 8.0, Acceptance Tests and Maintenance Program and the Certificate of Compliance.

2.2 Materials 2.2.1 Mechanical Properties of Materials The mechanical material properties used to evaluate the Versa-Pac performance are provided in Table 2-3. The thermal material properties used to evaluate the Versa-Pac performance are provided in Section 3.2.1.

2.2.2 Chemical, Galvanic Reactions and Other Reactions Appendix 2.13.1 contains information concerning the compatibility of the materials used to fabricate the Versa-Pac. This information demonstrates that the combined materials of construction do not experience significant material loss due to galvanic reactions.

Docket No. 71-9342 Versa-Pac Safety Analysis Report Rev 10, March 2018 2-5 There are two combinations of Versa-Pac materials of construction that have the potential for galvanic reaction. The first combination is steel, primer, ceramic fiber insulation, and polyurethane foam insulation. The second combination is steel and the payload. Other packages have successfully used this combination of materials without galvanic reactions and have done accelerated corrosion tests to support the combined use.

All of the insulation materials used in the construction of the Versa-Pac container have low chloride content. The fiber insulation used has been tested for its corrosive action on steel with acceptable results (see Appendix 2.13.1). Therefore, the first combination of materials is acceptable for use.

The payload material is pre-packaged to limit contact with the containment area. Therefore, a galvanic reaction with the payload is not considered credible. However, pre-shipment and maintenance inspections would identify any corrosion due to contact with the payload well before the structural integrity of the containment area would be compromised.

Additionally, the contents and plastic pre-packaging materials do not produce significant amounts of hydrogen gas by radiolysis, as the available decay to support the reaction is essentially zero (less than 11.4 W). The Versa-Pac is not a sealed system as the RTV (Silicone Rubber Compound) coated fibrous sleeve allows gas venting without passage of solids.

For the 1S/2S cylinder contents, the potential of hydrofluoric (HF) acid contamination is minimal.

Prior to loading into the Versa-Pac, all 1S/2S cylinders are cleaned to be free of chemical contamination. Each 1S/2S cylinder is packed with proper shoring/cribbing to prevent shifting and are supported during the NCT and HAC free drop events. The weight of a single fully loaded 1S and 2S cylinder are restricted to a maximum gross weight of 2.75 lb and 9.1 lb, respectively (Ref. [14], Table 4). Since the mass of the 1S/2S cylinders are small and are supported within the package, the cylinders are expected to survive both NCT and HAC. Therefore, the inleakage of water into the container holding the UF material and thus generation of HF acid is not a credible event. However, in the event of cylinder surface HF contamination, the corrosion of the Versa-Pac packaging components would not result in the release of fissile material.

Therefore, interactions among contents, packaging materials of construction and packing material satisfy the requirements of 10 CFR 71.43(d) [2].

2.2.3 Effects of Radiation on Materials The radiation produced by the authorized payloads is very low. The packaging materials used (steel, rigid polyurethane insulation products, ceramic fiber insulation products, silicone rubber, fluorocarbon) do not undergo significant changes in properties or performance due to their exposure to the authorized payloads.

Docket No. 71-9342 Versa-Pac Safety Analysis Report Rev 10, March 2018 2-6 Table 2-3. Mechanical Properties of Materials Property/Material Carbon Steel Plate and Sheet Note 1 Carbon Steel Bolts Note 1 Density (lb/ft3) 491 [12]

N/A Thermal Expansion Coefficient (in/in/F)

{9.22 x 10-6}

N/A Min Yield Strength (psi x 1,000)

{36}

{81}

Min Tensile Strength (psi x 1,000)

{58}

{105}

Elongation in 2 (%)

  • Elongation in 4D (%)

{21*}

{14}

Property Impact Absorbing Foam Insulation Density (lb/ft3) 5.0 - 11.0 (Per Table 1-7)

Nominal Thermal Expansion Coefficient (in/in/F) 3.4 x 10-5 [13]

Compressive Strength (psi) 85 - 300 (Per Table 1-7)

Notes on Table 2-3:

1. Information provided in {brackets} is an average or nominal for the material used and is provided for comparison purposes only, as it is not used in any evaluation presented for the packaging.

Docket No. 71-9342 Versa-Pac Safety Analysis Report Rev 10, March 2018 2-7 2.3 Fabrication and Examination 2.3.1 Fabrication The Versa-Pac is fabricated using Daher-TLI Standard Operating Procedures and Fabrication Control Records to document each step of the fabrication process (i.e., cutting of material, fitting, welding and other special processes). The Fabrication Control Records (FCR) become a part of the permanent Quality Assurance Record for the package. All welding is conducted in accordance with approved procedures, which are in compliance with the applicable code such as AWS D1.1

[4]. All insulation materials are procured in accordance with the requirements in Appendices 1.4.3, 1.4.4, and 1.4.5.

A typical fabrication sequence for the Versa-Pac Shipping Package begins with the cutting and forming of the individual components, which is carried out through the use of a Route Sheet system which provides the preparation group the details for all items. These items are inspected and once approved, released for production to begin the process of manufacturing the Versa-Pac.

The Fabrication Control Record (FCR) provides sequenced steps for the manufacturing of the Versa-Pac. These individual sequences give the quality assurance and production departments the instructions, standard operating procedures, welding procedures and inspection hold points for proper fabrication of the package.

Each sequence must be completed in order and the FCR step signed and dated by the individual responsible for that work, prior to moving to the next sequence. The FCR allows for QA or the customer to insert additional hold points at any location in the production process.

2.3.2 Examination All non-destructive examinations methods utilized in the fabrication of the Versa-Pac Shipping Package, are conducted in accordance with Daher-TLI Standard Operating Procedures, which are in accordance with appropriate codes, such as ASME [8] and AWS D1.1 [4] and/or D1.3 and applicable engineering specifications. Section 8 of this report specifies the requirements for fabrication acceptance and maintenance examinations of this package.

2.4 General Requirements for All Packages 2.4.1 Minimum Package Size The smallest overall dimension of the VP-55 is 22-1/2 inches in diameter and the smallest overall dimension of the VP-110 is 30-7/16 inches in diameter. The Versa-Pac thereby complies with the minimum package size requirement of 10 CFR 71.43(a) [2].

2.4.2 Tamper-Indicating Feature The Versa-Pac utilizes the outer drum ring closure bolt for installation of tamper indicating devices, typically individually numbered seals.

Docket No. 71-9342 Versa-Pac Safety Analysis Report Rev 8, May 2015 2-8 2.4.3 Positive Closure The primary containment is closed by use of a gasketed 1/2-thick blind flange with 12 carbon steel clad 1/2 bolts, flat washers and lock washers. The outer opening of the Versa-Pac is closed utilizing a reinforced insulated drum cover initially bolted through a gasketed surface with 4 carbon steel clad 1/2 bolts and flat washers on the VP-55 and 8 bolts on the VP-110. In addition, the standard 12-gauge drum closure ring with a 5/8 bolt. All closure bolts are torqued at 60 lb-ft.

2.5 Lifting and Tie-down Devices 2.5.1 Lifting Devices The Versa-Pac may be handled by normal industry standards for the safe movement of drums.

Such equipment might include specifically designed devices, forklifts, pallet jacks or other methods as determined by the user. However, the Versa-Pac does not utilize any specific device or attachment for lifting.

2.5.2 Tie-down Devices There are no specific provisions for tie-down of the Versa-Pac.

2.6 Normal Conditions of Transport (NCT)

The Versa-Pac meets the standards specified by 10CFR71 [2] when subjected to the conditions and tests required. The effectiveness of the package is maintained throughout all Normal Conditions of Transport.

2.6.1 Evaluation by Test Full-scale prototypes of both versions of the Versa-Pac Shipping Package were first tested in accordance with the (Structural) requirements specified by 10 CFR 71.71, Normal Conditions of Transport, and 10 CFR71.73, Hypothetical Accident Conditions, in July 2008. For package certification, additional NCT and HAC test series were conducted during the months of February and March of 2009 and the results are reported in Appendix 2.13.2. Additional testing including a shallow angle series of the VP-55 in September, 2009 and NCT penetration and stacking test in December of 2009.

The packages used for the test series were fabricated as specified by the packaging drawings provided in Appendix 1.4.1.

2.6.2 Evaluation by Analysis The drop test angles for the mechanical performance test series described in Appendix 2.13.2 were previously evaluated to determine the worst-case damage using finite element analyses in combination with a preliminary mechanical performance test series involving the Champion Type B package. The results of these analyses suggested that the crush tests would be most damaging to the package. The most damaging condition was observed in the subsequent testing of the Champion package. The calculations and test orientations for the Champion package are directly applicable to the Versa-Pac due to the similarity of the package design. The most damaging configuration was further demonstrated through a preliminary series of tests conducted on both Versa-Pac package design versions during July 2008. Crush tests were

Docket No. 71-9342 Versa-Pac Safety Analysis Report Rev 10, March 2018 2-9 conducted to impact the package side in the vicinity of the containment closure, main body below the containment closure and between vertical stiffeners, and the top of the package. A final series of tests with the VP-110 produced similar results. A complete description of the latter tests is provided in Appendix 2.13.2.

2.6.3 Heat 2.6.3.1 Summary of Pressures and Temperatures The peak payload temperature of the packaging is 176°F (80°C), under Normal Conditions of Transport (see Section 3.3.1.1). The material properties of the packaging remain essentially nominal at this temperature. This is well below the maximum allowable temperature of 600°F (defined in Section 3.1.3) for the contents. Since the Versa-Pac is not a sealed system, the maximum normal operating pressure is near atmospheric pressure.

2.6.3.2 Differential Thermal Expansion The Versa-Pac is basically constructed of steel and insulation components. Due to its relatively high thermal conductivity and the relative uniformity of the heat application, the steel components do not independently develop significant stresses due to differential thermal expansion.

The blanket insulation used is compressible, and therefore is not damaged by thermal expansion effects.

The linear thermal expansion coefficient of the rigid foam insulation is approximately four times that of the steel; therefore it is possible that the foam insulation expands more than the steel shell.

If the entire volume of the foam increases in temperature from 72°F to the peak steady state surface temperature of 144°F, the average maximum linear differential thermal expansion of the foam is about 1/16. However, due to the cyclic loading of the insulation, the actual volume of foam at 144°F is limited to less than 15% of the total foam volume and a more realistic estimate of the expansion is about 1/240. These very small expansion lengths are absorbed by the microstructure of the foam at the steel surface and by the allowable tolerances on the parts themselves. Therefore, no significant stresses are generated as a result of differential thermal expansion.

2.6.3.3 Thermal Stress Calculations Due to the decoupled design of the packaging, thermal stresses generated by the packaging are negligible.

2.6.3.4 Comparison with Allowable Stresses Not applicable.

2.6.4 Cold At an ambient temperature of -40°F with no insolation and zero decay heat generated by the contents, the package attains a uniform temperature of -40°F. At this temperature, the foam insulation compression strength and compressive modulus are increased. The increased foam (top and bottom of the package) strength and modulus result in a stiffer package response under drop conditions, and therefore more of the load is transferred to the containment boundary on

Docket No. 71-9342 Versa-Pac Safety Analysis Report Rev 8, May 2015 2-10 impact. Also, the carbon steel components may be brittle below -20°F. Performance testing of the package was completed at low temperature, demonstrating that the packaging performs as required under cold conditions.

No observable differences in damage were noted by comparison of prototype testing of the package at normal ambient temperatures (see Evaluation by Test, Section 2.6) to the performance testing conducted at low temperatures. Therefore, low temperature effects have little impact on the Versa-Pac performance.

2.6.5 Reduced External Pressure Although the internal pressure of a filled package is nominally atmospheric, the internal pressure of the containment may range from 0 to 2.0 psig (16.7 psia) for the normal condition. In the worst case, a reduced external pressure of 3.5 psia results in a net internal pressure of 13.2 psia or a net external pressure of 3.5 psia. These pressures are within the design internal and external pressure (25 psig) of the containment.

2.6.6 Increased External Pressure Although the internal pressure of a filled payload canister is nominally atmospheric, the internal pressure of the sealed canister may range from 0 to 2.0 psig (16.7 psia) for the normal condition.

In the worst case, an increased external pressure of 20 psia results in a net external pressure of 20 psia or a net external pressure of 3.3 psia. These pressures are within the design internal and external pressure (25 psig) of the containment.

2.6.7 Vibration Vibration incident to transport does not produce settling, compaction or a loss of structural cohesion for any of the materials used in the packaging. Vibrational compaction of the payload does not impact the performance of the packaging, since the criticality evaluation (see Section 6) applies a variable payload density up to the theoretical limit to evaluate the optimum condition.

Vibration testing conducted on the outer drum during the performance design qualification test as set forth in 49CFR178.608 [9] were successfully performed with past experience indicating no failure to the drum ring closure. In addition, the Versa-Pac includes an additional bolted closure through the top lid attached to the internal structure. This bolted closure utilizes 1/2 bolts and locking washers that are torqued to a prescribed rating of 60 lb-ft. to prevent the loss of the bolts during transportation. Thus, normal vibration incident to transport does not impact the performance of the Versa-Pac.

2.6.8 Water Spray A one-hour water spray simulating rainfall at a rate of 2 in/hr. has no effect on the Versa-Pac, as the outer vessel is designed to withstand exterior pressure loads much higher than those applied by the water spray.

The Versa-Pac utilizes multiple seals to prevent the loss or dispersal of its contents. Because it is clear that the water spray test has no effect on the package or contents, it was not conducted during the performance test sequence.

Docket No. 71-9342 Versa-Pac Safety Analysis Report Rev 10, March 2018 2-11 2.6.9 Free Drop Per regulatory requirement, the package must maintain its integrity and effectiveness when subjected to a free drop from a height of 4 feet (1.2 meters) onto a flat, essentially unyielding horizontal surface. Although the damage from a 4-foot free drop results in some local deformation of the transport unit, the deformation is well within the allowable specified for criticality safety, and structural stability. Three different drop orientations were conducted and the results of all five normal condition performance tests of the Versa-Pac are provided in Appendix 2.13.2.

Additional drop testing was performed with a VP-55 to increase the payload capacity to 350 lb.

This drop test series included the NCT free drop, which is documented in Appendix 2.13.7 2.6.10 Corner Drop This test is not applicable to the Versa-Pac packaging, as its weight exceeds the specified maximum of 220 lb.

2.6.11 Compression The primary load bearing members of the Versa-Pac are the steel 55 or 110-gallon drum shell, the vertical stiffeners, and the inner liner. These components, when assembled as a unit, can be analyzed as an axial member in compression. Assuming the metal thickness is 0.036 and 0.05 for the drum and inner liner, respectively, and using 1-1/4 x 1-1/4 x 0.12 for conservatism (the actual thicknesses are 0.06, 0.0598, and 0.135 respectively), the load-bearing cross-sectional area is approximated as:

(22.5.)(0.036 in.) + (19.25.)(0.05 in.) + 4(1.25.41.01.4 ) = 7.738.4 Five times the weight of the package is:

(5)(965 ) = 4,825 The compressive stress on the steel members is:

4,825 7.738.4 = 623

The margin of safety against compressive failure is:

.. = A36,000 623 B

C 1 = 56.7 For empty Packaging Five times the weight of the packaging is:

(5)(390 ) = 1,950

Docket No. 71-9342 Versa-Pac Safety Analysis Report Rev 8, May 2015 2-12 The compressive stress on the steel members is:

1,950 7.738.4 = 252

The margin of safety against compressive failure is:

.. = A36,000 252 B

C 1 = 141.85 The structural members of the Versa-Pac are comprised of a variety of thicknesses of steel components, although when combined through the process of manufacturing act in conjunction with one another to produce an exceptionally strong unit. To further demonstrate that the Versa-Pac meets the requirements set forth in 10 CFR 71.71(c)(9) [2], the Versa-Pac was subjected to a load greater than 5 times the weight of the package for a period of 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> without any damage.

The VP-55 was tested and the results are provided in Appendix 2.13.5: NCT Versa-Pac Test Report for Compression and Penetration.

Conclusion Based upon the calculations providing a large margin of safety against compressive failure and the physical testing performed using the previously tested VP-55 described above and reported in Appendix 2.13.5 NCT Versa-Pac Test Report for Compression and Penetration, the Versa-Pac meets and exceeds the requirements specified in 10CFR71.

2.6.12 Penetration Impact from a 13-pound rod as described in 10CFR71 does not penetrate the steel shell of the Versa-Pac.

The Versa-Pac was subject to the penetration test described in 10CFR71.71(10) [2]. The test was performed using a 1.25-inch diameter steel bar weighing 13.2 pounds and dropped from a height of 40 inches (1 Meter) onto several different areas of the test package considered to be the weakest parts of the package without measurable damage at the impact point. These results are supplied in Appendix 2.13.5 NCT Versa-Pac Test Report for Compression and Penetration.

2.7 Hypothetical Accident Conditions (HAC)

The Versa-Pac meets the standards specified by 10CFR71 when subjected to the conditions and tests required. Analytical techniques were used to determine the test orientations producing the maximum damage. Representative prototypes were constructed and tested on two separate occasions using both package designs (VP-55 and VP-110) to demonstrate that the package performs as required to transport the payload. A detailed report of the tests performed is provided in Appendix 2.13.2.

The compliance testing demonstrated:

The Versa-Pac provides sufficient thermal protection to prevent the internal temperature of the payload container from exceeding the maximum design temperature of the containment boundary (500°F) during and following HAC;

Docket No. 71-9342 Versa-Pac Safety Analysis Report Rev 10, March 2018 2-13 The average OD of the package, and the required package height is maintained under HAC (specified in Section 6) is maintained under all conditions; and Containment of the payload is maintained.

Therefore, the Versa-Pac provides adequate protection to the payload during HAC as defined by 10CFR71.73 [2].

2.7.1 Free Drop The full-scale representatives of the VP-110 containing a simulated payload were subjected to a variety of sequenced drops, punctures, shallow angle drops and crush test, specified by 10CFR71.73 [2] and outlined in the test plan and report in Appendix 2.13.3. The same prototype was used for each test sequence in succession, with no repairs between the tests. The test prototypes were fabricated to the drawings and specifications provided in Appendix 2.13.2.

All drop tests were performed on the same 70-ton pad which is 10 x 10 x 10 deep reinforced with a grid of 3/4 re-bar spaced on 12 center and capped with an 8 x 10 x 1 thick steel plate which is embedded to the surface of the concrete and secured to it with fourteen 1-1/2 diameter x 16 long bolts. A quick-release mechanism was used to release the prototypes from the drop height without imparting rotational or translational motion to the prototype. For the puncture drop, a puncture ram was welded to the test pad. The ram is a 6 diameter by 18 long right circular cylinder, fabricated from mild steel and welded to the pad reinforcement plate. The solid steel plate used for the dynamic crush test weighs 500 kg and is 1m by 1m in cross section. The tests were video taped and photographed, and post-drop damage measurements were recorded after each drop.

In order to determine the worst-case initial temperature conditions for the drop tests, the performance characteristics of the primary Versa-Pac fabrication materials were evaluated. The primary structural and sealing materials include carbon steel, polyurethane foam, and silicone rubber. Because carbon steel may exhibit brittle failure mechanisms at temperatures below 0°F and the other materials are essentially unaffected over the design temperature range, the initial condition temperature selected is -20°F. For consistency with the minimum design operating temperature specified by international regulations, the impact testing initial ambient condition selected is -40°F.

The payload utilized for the drop test series consisted of a 30-gallon drum that was filled with approximately 226 lb of different size gravel with an additional 1 to 1-1/2 lbs. of loose play sand, which was placed on the top of the 30-gallon drum, combining for a test payload of 260 lbs. The blind flange was secured by tightening the bolts to an initial torque of 40 lb-ft. The decay heat generated by the contents is negligible; therefore, heat generated by the contents was not simulated. The Versa-Pac was then subjected to an ambient air temperature of approximately -40°F for 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />. Upon removal from the conditioning chamber, the exterior skin of the shipping package recorded a temperature of -28°F at time of transport to the test pad.

Additional drop testing to increase the VP-55 payload capacity to 350 lb includes the HAC Free Drop. For the HAC Free Drop, center of gravity over corner was selected as the most damaging orientation for the VP-55. The test was performed on the same package article that was dropped through the NCT Free Drop, but on the opposite side of the drum lid. The drum ring experienced

Docket No. 71-9342 Versa-Pac Safety Analysis Report Rev 10, March 2018 2-14 local tearing due to the HAC Free Drop, but there was no loss of material from the containment.

The HAC Free Drop is fully documented in Appendix 2.13.7.

The corner orientation for free drop was selected based on the information presented in Section 2.7.3.2 that states Test Article 10550, which was subjected to the corner and oblique drops, had its containment lid sufficiently damaged that it could not be resealed for further testing. Articles 10551 and 10552, which were not subjected to corner drops, could be closed again. Based on this information, the corner drop was chosen as the bounding drop orientation. In addition, an objective of the test was to subject the package to the conditions that would most likely result in the lid of the test article detaching from the package. Having the NCT and HAC free drop on opposite corners of the lid, crush on the side of the package, and the pin puncture in the center of the lid were chosen to promote the detachment of the lid from the package.

2.7.1.1 End Drop After cooling, test package serial number 10552 was positioned with the top end of the package positioned over the test pad at an angle of 0 degrees so as to impact the container directly onto the top surface of the package. This drop series is intended to test the top closure of the package and the internal containment closure components.

Test Record Number - TS-001-1 Test Number 1A - NCT 4 Top End Drop The initial drop was made from a height of 4 onto the target pad, and the external damage was recorded and documented with both video and still photography. As result of the impact no visible damage was accumulated. All welds, closures and bolts remained intact. The package was not opened after the Normal Condition Drop, but was prepared for the 30 HAC Drop.

Test Number 1B - HAC 30 Top End Drop Following the Normal Conditions Drop, the package was positioned for the HAC 30 drop onto the same surface and orientation of 0 degrees. Post-drop inspection documented that the overall height of the package was reduced by 1/4 inch and that the diameter was increased by 1/6 inch.

An area measuring a total of 2 and 3/8 inches long at the bolt closure was crumpled in slightly. All welds, closures and bolts remained intact. The package was not opened, but was set aside for use in the puncture test listed in Test Record TS-001-1 Number 1C.

2.7.1.2 Side Drop After cooling, test package number 10551 was positioned in a level horizontal position over the test pad. This drop series was designed to test the impact on the bolt closure of the package on its side, along with inner containment closure when exposed to the impact.

Test Record Number - TS-001-2 Test Number 2A - NCT Horizontal Side Drop The initial drop was made from a height of 4 onto the target pad, and the external damage was recorded and documented with both video and still photography. The result of the impact to the exterior surface of the package was that the closure bolt was pushed into the package sidewall approximately 5/8 inch. No reduction in height or diameter occurred. All welds, closures and bolts remained intact.

Docket No. 71-9342 Versa-Pac Safety Analysis Report Rev 8, May 2015 2-15 Test Record Number - 2B - HAC 30 Horizontal Side Drop The same test package was positioned for the HAC 30 drop onto the same horizontal surface as the Normal Conditions Drop in an effort to shown accumulated damage in the side drop orientation. Resultant damage from this drop accounted for a buckling around the closure bolt area and on the lid and a decrease in the diameter of 1 inch in the bolt impact direction. There was no loss of bolts or closure and all welds remained intact. The package was then subjected to the crush plate drop described below and recorded in TS-001-2 Record Number 3C.

2.7.1.3 Corner Drop Upon cooling, test package number 10550 was in a position with the center of gravity impact to be through the package bolt closure over the test pad. This drop series was designed to test the impact on the bolted closure of the package through its center of gravity, along with inner containment closure when exposed to the impact.

Test Record Number TS-001-3 Test Number 3A - NCT Center of Gravity Drop The normal condition, center of gravity drop from a height of 4 through the bolted closure at an angle of 57 degrees was recorded and documented using both video and still photography. The impact resulted in a deformation on the drum side at the closure bolt with measurements of 1-1/16 inch deep by 2 inches long. All welds, bolts and closures remained intact.

Test Record 3B - HAC Center of Gravity Drop The package was repositioned in the same attitude of 57 degrees so as to impact the identical area tested in 3A above over the test pad at a height of 30 form the lowest point of the package.

The impact resulted in a depression 11/16 inches deep into the lid and additional side deformation totaling 2-1/2 deep by 20 inches long. All welds, bolts and closure remained intact. The package was then readied for the HAC oblique (Shallow) angle drop described below.

2.7.1.4 Oblique Drop Using test package number 10550 an oblique drop of 17 degrees was positioned of the test pad so as to initially impact the top closure with the resulting acceleration impact to attack the bottom of the package. This drop was also intended to test the inner containment area closure system.

Test Record Number 3C - HAC Shallow Angle Drop (Slap Test)

The package was positioned over the test pad at 17 degrees from the horizontal position with the lowest point of the package 30 from the target surface. The damage to the package exterior surface produced a tear at the exterior drum side to bottom rim connection point measuring 3/16 inch at its widest point by 7 inches in length. Although this slit in the outer drum occurred, no internal breach of the inner liner occurred, remaining completely sealed from the exterior atmosphere. Additional deformation at the bolted closure affected an area measuring 2-15/16 inches deep with a 1-inch crumple in the lid. The diameter of the package across the top surface only, of the outer drum lid, was reduced in the direction of the impact upon the bolt, by approximately 3 inches, which coincides with the deformation described above. The package was then readied for a puncture test to be described below and listed in Test Record TS-001-3 Number 3D.

Docket No. 71-9342 Versa-Pac Safety Analysis Report Rev 10, March 2018 2-16 2.7.1.5 Summary of Results The initial drops of this test series provided information showing that the package design was capable of withstanding multiple impacts with only minor damage to the exterior surfaces of the package this point. Complete measurements along with full photographic and written documentation are included in Appendix 2.13.3. Drop test series complete summary of results are noted in 2.7.3.1 below.

2.7.2 Crush Based upon past history and an attempt to attack the top closure mechanism of the package system, the test package previously used in horizontal drop of Test Record TS-001-2 was positioned on the test pad in a horizontal attitude. The crush plate was placed to impact the package directly on both the closure and top flange areas and also over the bottom edge of the package. The purpose of this test was to test both the internal and exterior closures and surfaces of the test package.

Test Record Number 2C - HAC 30 Crush Plate Side Drop The crush plate was suspended at an angle of 0 degrees directly over the test package and lifted to a height of 361 inches from the lowest point of the test plate to the top of the test package surface. Upon impact the overall diameter of the package in the direction of the impact was reduced by 2-1/2 inches from its original shape at its maximum point. A gap of 1/4 inch by 1-1/4 inch long was documented at the drum lid to drum rim interface. Due to the design of the closure lid a metal-metal interface was visible with no direct opening to the internal structure or seals.

Additional drop testing to increase the VP-55 payload capacity to 350 lb includes the HAC Dynamic Crush. For the HAC Dynamic Crush, the VP-55 laid on its side with the plate dropped on its other side was the chosen orientation. The test was performed on the same package article that was dropped through the NCT and HAC Free Drop tests. The drum experienced flattening on the side of drum resting against the ground and the side that was struck by the crush plate.

There was no leakage of material to the package outer surface. The HAC Dynamic Crush test is fully documented in Appendix 2.13.7.

2.7.3 Puncture Prototypes of both the VP-55 and VP-110 were subjected to the puncture test in a variety of orientations including side, center bottom, center top and center of gravity through the bolt closure. The most damage to the exterior surface of the package was through the center of gravity onto the closure and by attacking the side between the vertical stiffeners. Based upon this data both areas were punctured during this test series. The packages were lifted to a height of 41 inches above the top of the puncture ram, which was welded to the top surface of the drop test pad.

Test Record Number 1C - HAC 1 Meter Puncture Drop - Horizontal The suspended package was positioned level and horizontal (1 degree) so that the impact location was between two of the vertical stiffeners and in the middle of package. The test was recorded and documented using video and still photography. The deformation upon measurement was a maximum of 3/8 inch deep. The package sustained no tears as a result of the puncture drop.

Docket No. 71-9342 Versa-Pac Safety Analysis Report Rev 10, March 2018 2-17 Test Record Number 3D - HAC 1 Meter Puncture Drop - CG Over Bolt Closure The package was positioned with the center of gravity through the bolted closure at an angle of 56 degrees from a height of 41 inches from the lowest point of the package to the top of the puncture ram. The drop test was recorded and documented using both video and still photography. The impact resulted in additional damage on the drum side at the closure bolt with a small separation of 1/4 inch by 3 inches long at the drum lid and drum rim interface. The opening was sealed by metal-metal contact between the flange and the drum lid insulation sheet metal cover and the top gasket material, which remained intact.

Additional drop testing to increase the VP-55 payload capacity to 350 lb includes the HAC Puncture test. For the HAC Puncture test, the VP-55 was dropped upside down such that the center of the lid would strike the pin. The test was performed on the same package article that was dropped through the NCT and HAC Free Drop test and the HAC Dynamic Crush test. The drum lid experienced a large local deformation, but the package was not breached. Also, the position of the outer drum ring was not affected such that the package height was not reduced.

There was no leakage of material to the package outer surface. The HAC Puncture test is documented fully in Appendix 2.13.7.

2.7.3.1 Summary of Damage Upon completion of the drop test series all test packages were inspected for damage, the torque of the bolts recorded and internal condition and damage noted.

Test Record Number TS-001 Top End Drops - Package Serial Number 10552 The series of test conducted included a 4-foot top end drop, a 30-foot top end drop and a horizontal side puncture drop. Outer closure bolts recorded a torque of 30 lb-ft. The outer lid was removed exposing a bulge in the inner containment flange. The bulge in the inner flange allowed sand, which was placed on the top of the payload 30-gallon drum to be forced under the containment gasket. It is believed that the piston action within the inner drum payload provided a secondary impact force upon the primary containment flange thus causing the flange to bulge.

Containment flange bolts were torqued prior to removal and recorded at 20 lb-ft. Gaskets and the internal condition of the package were found to be in good condition with no damage.

Test Record Number TS-001 Horizontal Side & Crush Plate Drops - Package Serial Number 10551 The test article series of drops included a 4-foot horizontal side drop, a 30-foot horizontal side drop and a 30-foot crush plate side drop. Although, the outer drum ring was dislodged during previous testing the package remained closed and in place due to the additional top closure bolt design of the Versa-Pac Shipping Package. The outer closure bolts of the top cover were torqued and recorded a reading of 25 lb-ft. Upon removal of the outer lid inspection revealed a slight interior wall deformation in the upper plug well of the package. There was no loss of contents.

The containment flange was in good condition and the bolts recorded a torque of 25 lb-ft. Gaskets were in good condition. The inner payload drum lid exhibited some buckling from the piston action of the internal payload within the drum. This payload comprised of gravel and sand acted as an additional piston action within the body of the drum. Upon removal of the inner containment payload visual inspection was conducted with no damage shown within the inner containment cavity.

Docket No. 71-9342 Versa-Pac Safety Analysis Report Rev 8, May 2015 2-18 Test Record Number TS-001 Center of Gravity, Shallow Angle & Puncture -

Package Serial Number 10550 This series consisted of a 4-foot center of gravity drop, a 30-foot center of gravity drop, a 30-foot shallow angle drop and a center of gravity puncture drop. Upon completion of these drops the test package outer closure bolts were torqued with readings found to be less than 20 lb-ft. upon removal of the outer lid inspection revealed a deformation of the inner wall at the impact area. A bulge in the inner containment flange was also noted along with some sand from the inner containment area. This again was due to the piston action coming from the internal payload during the impact and corresponding secondary impact from the payload. The gaskets were found to be in good condition. Upon removal of the inner containment payload a visual inspection was conducted with no damage found to the internal cavity.

2.7.3.2 Conclusions Based upon the information obtained from the series of drops conducted it was determined that the two of the drop series results were unsatisfactory and that additional testing would be conducted. It was determined that three primary causes were responsible for the bugling of the internal containment flange and the resultant loss of sand from the top of the inner payload. The first being that the flange in itself was under sized at 3/16 inch thick and secondly, that the thickness of the silicone coated fiberglass gasket used in sealing the containment allowed a flexing at the interface of gasket and flange. The third potential cause was the removal of the gasket pad located between the inner flange and the payload.

In order to correct this condition the flange was increased to a thickness of 1/2 inch. This would accommodate a greater torque to be applied to the sealing of the inner containment area and provide a much higher strength to support the internal piston action within the payload area. Also the gasket pad would be reinstalled between the payload and the inner flange surface.

After evaluating the three test articles, two were chosen for reuse in an additional round of testing.

The packages chosen were in good condition and were able to be resealed after their original series of testing. These package serial numbers were 10551 and 10552.

2.7.3.3 Package Preparation Both previously dropped packages were carefully inspected and measurements of height and diameter recorded on new testing records. The payloads were identical to the original test series, with 1.5 pounds of sand placed on top of and around the payload as before. The test articles were fitted with new 1/2-inch thick inner containment flanges with 3/8-inch thick neoprene sponge rubber pads affixed to the inside of the inner flange lid prior to installation. The torque of the inner containment bolts was also increased for a better seal on the 1.8-inch thick silicone rubber coated fiberglass gasket to 60 lb-ft. The outer container lid was put into place and bolts torqued to 60 lb-ft.

The test articles were then placed in the cooling chamber for 18 hours2.083333e-4 days <br />0.005 hours <br />2.97619e-5 weeks <br />6.849e-6 months <br /> prior to the new drop tests.

2.7.3.4 Second Round End Drops After cooling, test package serial number 10551 was positioned with the top end of the package positioned over the test pad at an angle of 0 degrees so as to impact the container directly onto the top surface of the package. This second round drop test series was intended to test the top closure of the package and the internal containment closure components and to validate that the

Docket No. 71-9342 Versa-Pac Safety Analysis Report Rev 8, May 2015 2-19 changes made to the inner containment flange would prove to correct the loss of materials previous found during the original drop testing.

Second Round Test Record Number - TS-001-4 Second Round Test Number 1A - NCT 4 Top End Drop This drop was made from a height of 4 onto the target pad, and the external damage was recorded and documented with both video and still photography. As result of the impact no visible damage was accumulated. All welds, closures and bolts remained intact. The package was not opened after the Normal Condition Drop, but was prepared for the 30 HAC Drop.

Second Round Test Number 1B - HAC 30 Top End Drop Following the Normal Conditions Drop, the package was positioned for the HAC 30 drop onto the same surface and orientation of 0 degrees. Post-drop inspection documented that the overall height of the package was reduced by 7/16 inch and that the drop test did not affect the diameter.

All welds, closures and bolts remained intact.

Prior to opening the test article the bolt torque of the outer closure was measured and found to be between 20 to 80 lb-ft. with all bolts intact. After opening the package photographs were taken and the interior well surfaces inspected with no damage found. The new thicker blind flange remained flat, sealed and no loss of payload contents were found outside the inner containment area. The bolts of the interior containment were torqued and found to be at a torque of 30 to 50 lb-ft. The gasket and payload were in good condition.

2.7.3.5 Second Round Corner Drop After cooling, test package number 10552 was in a position with the center of gravity impact to be through the package bolt closure over the test pad. This second round drop series was designed to test the impact on the bolted closure of the package through its center of gravity, along with inner containment closure when exposed to the impact and to verify that the changes made to the test article were sufficient to correct the loss of contents in this previously tested series of drops.

Second Round Test Record Number TS-001-5 Second Round Test Number 3A - NCT Center of Gravity Drop The normal condition drop center of gravity drop from a height of 4 through the bolted closure at an angle of 57 degrees was recorded and documented using both video and still photography.

The impact resulted in a deformation on the closure bolt area with measurements of 1-3/16 inch deep by 2-1/4 inches long. All welds, bolts and closures remained intact.

Second Round Test Record 3B - HAC Center of Gravity Drop The package was repositioned in the same attitude of 57 degrees so as to impact the identical area tested in 3A above over the test pad at a height of 30 form the lowest point of the package.

The impact resulted deformation totaling 2-9/16 deep by 20-1/2 inches long. All welds, bolts and closures remained intact. The package was then readied for the HAC oblique (Shallow) angle drop described below.

Docket No. 71-9342 Versa-Pac Safety Analysis Report Rev 8, May 2015 2-20 2.7.3.6 Second Round Oblique Drop Using test package number 10552, a second oblique drop of 17 degrees was positioned of the test pad so as to impact the top closure with the resulting acceleration impact to attack the bottom of the package. This second round drop was also intended to test the inner containment area closure system and to provide evidence that the changes made to the test article corrected the loss of content problem previously found in the original testing.

Second Round Test Record Number 3C - HAC Shallow Angle Drop (Slap Test)

The package was positioned over the test pad at 17 degrees from the horizontal position with the lowest point of the package 30 from the target surface. The damage to the package exterior surface produced deformation on the initial top closure measuring 2-15/16 inches deep with a 1-inch crumple in the lid. Secondary impact produced damage measuring 5 inches in length on the bottom rim of the test article. Diameter of the package was reduced in the direction of the impact area through the bolt by approximately 1 inch.

Before opening the outer closure the torque was measured and found to be less than 20 lb-ft.

Photographs were taken and inspection of the inner well area found only minor deformation within the sidewalls of the well area, no other damage was found. The inner flange was flat and sealed with no loss of contents form the internal containment area.

2.7.3.7 Secondary Test Series Conclusion With the changes made to the inner blind flange closure, increasing the thickness of the flange, increasing the torque of the bolts and reinstalling the containment flange pad the Versa-Pac Shipping Package successfully completed the drop test evaluation series.

2.7.3.8 55 Gallon Shallow Angle (Slap-Down) Drop Test Series - Test Record Number TS-002-1 This series of testing was conducted to provide additional information and verification that the VP-55 would demonstrate the capability to successfully meet the requirements set forth with similar results provided by previously conducted testing of the VP-110 when subjected to the effects of both NCT and HAC Shallow Angle Drops. The package contained 254.5 pounds of payload consisting of gravel, steel bars (to amplify the secondary piston impact effect) and 1.5 pounds of loose sand for a total weight of 644.5 pounds. All bolts were torqued to 60 lb-ft at closure of the blind flange and top closure lid.

2.7.3.9 Oblique Drop Using the VP-55 test package number 10553, an oblique drop of 17 degrees was positioned on the test pad so as to initially impact the top closure with the resulting acceleration impact to attack the bottom of the package. This drop was also intended to test the inner containment area closure system. The drop angle of 17 degrees was chosen based upon previous drop history of like packages and drop information found and recorded in NUREG/CR-6818 [10]. The puncture drop was chosen after the initial drops to attack the most vulnerable area of the package base upon the damage from the shallow angle NCT and HAC drops to the package.

Test Record Number 1-55-A - NCT Shallow Angle Drop (Slap Test)

Docket No. 71-9342 Versa-Pac Safety Analysis Report Rev 10, March 2018 2-21 The package was positioned over the test pad at 17 degrees from the horizontal position with the lowest point of the package 4 from the target surface. The damage to the package exterior surface produced only minimal damage to the impact side of the test package, with an area 7-1/4 long at the widest points on the top closure end and a impact are 5-3/4 in width at the bottom edge. Minor indentation along the outer drum rolling hoops was also noted. Both flattened areas were approximately 1/4 in depth. There was no tearing or opening of the package. The package was then readied for a puncture test to be described below and listed in Test Record TS-001-3 Number 3D.

Test Record Number 1-55-B - HAC Shallow Angle Drop (Slap Test)

The test package was then positioned over the test pad at 17 degrees from the horizontal position with the lowest point of the package 30 from the target surface. Damage to the package consisted of a small ripple in the middle of the outer drum lid with minor flattening of the outer drum rolling hoops. Additional damage to the top closure, initial impact area was noted increasing the length of the area to 11-1/2 long by 3/8 deep and the bottom closure, secondary impact increasing to 10 long by 1/4 deep. The bolt closure ring of the outer drum was pushed into the sidewall of the outer drum producing a small tear in the drum sidewall material at the top rolling hoop, but due to the design of the package there was no breach or tearing of the Versa-Pacs inner liner, which is adjacent to the outer drum. The drum closure ring lug was also broken with the impact, but the top closure remained intact and secure due to the top closure bolts of the package.

Test Record Number 1-55-C - HAC 1 Meter Puncture Drop - CG Over Bolt Closure The package was positioned with the center of gravity through the bolted closure at an angle of 56.5 degrees from a height of 41 inches from the lowest point of the package to the top of the puncture ram. The drop test was recorded and documented. The impact resulted in additional damage to the outer drum closure ring and lid interface with an impact deformation measuring 8-3/8 in diameter. There was no tearing or opening of the package as a result of the puncture drop.

2.7.3.10 VP-55 Test Series Conclusion Based upon the results of the test series, the VP-55 has demonstrated that it is capable of meeting the requirements set forth in 10CFR71 [2] and Century Industries Test Plan TP-002 Revision 0

[11] by retention of the outer closure, no openings, tears or failure that would lead to the loss of material, no open pathway to the insulation materials and no loss of the inner containment payload. The overall diameter of the package through the impact area was reduced by 1/2, but remained the same in the opposite direction.

2.7.4 Thermal A thermal test was not performed on the test prototype in its damaged condition following the drop test sequence. However, the package was analytically evaluated as indicated in Section 3. Based on testing of a similar package (Champion) as presented in Section 3.6.3, the analytically calculated values appear to be conservative.

2.7.4.1 Summary of Pressures and Temperatures The Versa-Pac was evaluated for HAC described in Section 3.4. The maximum temperature recorded at the payload cavity during the fire event was 429°F at the top of payload cavity, just

Docket No. 71-9342 Versa-Pac Safety Analysis Report Rev 10, March 2018 2-22 below the polyurethane plug, as shown in Figure 3-16. This temperature is well below the maximum HAC allowable temperature of 600°F. Since the Versa-Pac is not a sealed system, the maximum normal operating pressure is near atmospheric pressure. In addition, the Versa-Pac features pressure plugs that will relieve any pressure build-up between the Versa-Pac inner and outer walls due to HAC.

2.7.4.2 Differential Thermal Expansion As discussed in Section 2.6.1.2, the materials used to fabricate the Versa-Pac and the arrangement of the packaging limit the effects of differential thermal expansion. No significant stresses are generated as a result of differential thermal expansion.

2.7.4.3 Stress Calculations Due to the decoupled design of the packaging, thermal stresses generated by the packaging are negligible.

2.7.5 Immersion - Fissile Material Moderator inleakage to the most reactive credible extent is assumed for the Versa-Pac and evaluated in Section 6.0. Thus, the fissile material immersion test is not required.

2.7.6 Immersion - All Packages Regulations require that an undamaged package be capable of sustaining a hydraulic pressure of 50 feet of water. As indicated in Appendix 2.13.3, a similar damaged prototype was placed in an immersion chamber at 23 psig for 15 minutes. As expected, due to the reinforcements within the drum, no further damage was noted.

2.7.7 Deep Water Immersion Test This section is not applicable to the Versa-Pac Shipping Package.

2.7.8 Summary of Damage The series of drop tests (3 initial series and 2 second round series a total of 5 in all) completed were performed for the worst-case packaging orientations, worst-case initial packaging temperature, and with a maximum payload onboard. The test article was moderately deformed at the impact sites. Due to impact from testing, only minor changes in the diameter were found with measured diameter changing primarily at the impact points only. The worst case of oval conditions at impact points were major and minor diameters of 31-5/8 and 28-1/2, respectively, following the center of gravity and shallow angle drops in Test Series TS-001-3. The majority of test article diameters remained constant throughout the test series. The maximum overall height of a deformed package was 42-1/4 and the minimum height was 41-5/8. All bolts remained intact during all test series with the exception of the loss drum ring in test number 2C Crush Plate Drop.

Although the closure ring was lost, there was no opening of the test article due to the design of the Versa-Pac and its top bolts. The impact of the puncture test conducted produced only minor damage with indentations of 1/4 and 3/8. One exterior drum surface tear occurred at the bottom of the drum rim upon impact, during the secondary impact of the initial shallow angle drop 3C, but due to the inner liner design of the Versa-Pac, with a sealed steel liner directly adjacent to the drum skin, no breach of the container occurred. A small gap from the impact in test number 2C at

Docket No. 71-9342 Versa-Pac Safety Analysis Report Rev 10, March 2018 2-23 the lid to drum rim interface was sealed with a metal to metal contact of the lid steel insulation cover and the top side wall and gasket.

The second series of tests conducted confirmed that the increase in thickness of the blind flange, the increase in bolt torque, and the addition of the neoprene sponge rubber pad attached to the inside of the flange corrected the loss of payload contents that occurred in the original test series.

With the changes, no tears, no broken welds, no openings, and no broken bolts were found. The inner flange remained flat and sealed as required.

The VP-55 drop test series produced expected damage to the impact areas with no loss of containment and no damage that would lead to loss of materials. It supported the evidence based upon physical testing that the VP-110 bounds the smaller VP-55 of the Versa-Pac Shipping Package system.

There was no damage or shift to the inner containment area during any of the five separate test series.

The results of the test series demonstrate that the packaging is maintained within the allowable temperature, pressure and stress ranges. The average OD of the packaging is maintained greater than 21.5 and the minimum height of the packaging is maintained greater than 34 under all conditions as required for criticality control. There is no breach of the containment area and thus no loss or dispersal of radioactive contents. Thus, the packaging is acceptable for use.

2.8 Accident Conditions for Air Transport of Plutonium This Section is not applicable to the Versa-Pac.

2.9 Accident Conditions for Fissile Material Packages for Air Transport This section is not applicable to the Versa-Pac. The criticality analysis for Versa-Pac packages transported by air assumes ejection of all contents from the packaging into a bounding configuration (See Section 6.7). Thus, no structural testing/analyses are necessary for Versa-Pac shipments via air transport.

2.10 Special Form Special form material as defined in 10CFR71 is not applicable to the Versa-Pac.

2.11 Fuel Rods This section is not applicable to the Versa-Pac.

Docket No. 71-9342 Versa-Pac Safety Analysis Report Rev 10, March 2018 2-24 2.12 References

[1] United States Department of Transportation (USDOT), "Code of Federal Regulations, Title 49: Transportation," 2004.

[2] Nuclear Regulatory Commission (NRC), Title 10, Part 71-Packaging and Transportation of Radioactive Material.

[3] Nuclear Regulatory Commission (NRC), "Title 10, Part 71-Packaging and Transportation of Radioactive Material, Subpart H - Quality Assurance".

[4] American Welding Society (AWS), "D1.1/D1.1M:2010, Structural Welding Code - Steel".

[5] The American Society for Nondestructive Testing, Inc., "Recommended Practice No. SNT-TC-1A Personnel Qualification and Certification in Nondestructive Testing," 2006.

[6] International Atomic Energy Agency (IAEA), Regulations for the Safe Transport of Radioactive Material, SSR-6, 2012 Edition.

[7] Daher-TLI, "QUALITY ASSURANCE PROGRAM DESCRIPTION," Rev. 1, 2016.

[8] The American Society of Mechanical Engineers (ASME), "Boiler and Pressure Vessel Code, BPVC-IX -- Section IX, Welding and Brazing Qualifications," 2015.

[9] United States Department of Transportation (USDOT), "Title 49, Code of Federal Regulations Part 178, Specifications for Packagings, Subpart MTesting of Non-bulk Packagings and Packages".

[10] Nuclear Regulatory Commission Office of Nuclear Material Safety and Safeguards, "Drop Test Results for the Combustion Engineering Model No. ABB-2901 Fuel Pellet Shipping Package".

[11] Century Industries, "Versa-Pac Shipping Container Test Specification TS-002, Revision 0".

[12] R. B. Ross, Metallic Materials Specification Handbook, 4th Edition, London: Chapman and Hall, 1992.

[13] General Plastics, "Design Guide LAST-A-FOAM FR-3700 Crash & Fire Protection of Radioactive Material Shipping Containers".

[14] American National Standards Institute (ANSI), For Nuclear Materials Uranium Hexafluoride - Packagings for Transport, ANSI N14.1-2012, 2012.

Docket No. 71-9342 Versa-Pac Safety Analysis Report Rev 10, March 2018 2-25 2.13 List of Appendices 2.13.1 MACTEC Report on Material Compatibility 2.13.2 Performance Test Report for the Versa-Pac 2.13.3 Excerpted from Safety Analysis Report for the Century Champion Type B Package Immersion Test 2.13.4 Performance Test Report for the 55 Gallon Versa-Pac (Shallow Angle Drops) 2.13.5 NCT Versa-Pac Test Report for Compression and Penetration 2.13.6 Performance Test Report for the VP-55 5-Inch Pipe Container 2.13.7 55 Gallon Versa-Pac Drop Test Deformation Measurement Report

Docket No. 71-9342 Versa-Pac Safety Analysis Report Rev 8, May 2015 2-26 Table 2-1 Evaluation Results Evaluation Evaluation Result Evaluation Criteria Minimum Factor of Safety (FS)1 or Design Margin (DM)2 Minimum package size Versa-Pac is 24 x 35 10CFR71.43(a)

N/A Package is acceptable Tamperproof feature One per package, Closure Ring Bolt 10CFR71.43(b)

N/A Package is acceptable Positive Closure 110 Gallon Versa-Pac uses 20 bolts to secure the packaging & the 55 Gallon Versa-Pac uses 16 10CFR71.43(c)

N/A Package is acceptable Chemical &

Galvanic reactions The materials do not react chemically and galvanic reactions are acceptable over the packaging life 10CFR71.43(d)

N/A Package is acceptable Lifting N/A 10CFR71.45(a)

N/A Package is acceptable Tie down N/A 10CFR71.45(b)(1)

N/A Package is acceptable Differential thermal expansion Foam maximum expansion ~0.004 Stress developed ~ 0 psi in both foam and steel components Yield strength FS ¥ Thermal Stress N/A Package uses a de-coupled design that minimizes thermal stresses Steel yield strength Foam compressive strength FS ¥ Cold Packaging temperature

= -40°F Minimum allowable, -40°F FS = 1.0 Reduced External Pressure Effective pressure differential = 16.7 psia internal or 3.3 psia external Containment rated to 15 psig FS = 1.7

Docket No. 71-9342 Versa-Pac Safety Analysis Report Rev 10, March 2018 2-27 Table 2-1 Evaluation Results Evaluation Evaluation Result Evaluation Criteria Minimum Factor of Safety (FS)1 or Design Margin (DM)2 Increased External Pressure Effective pressure differential = 20 psia external or 3.3 psia external Containment rated to 15 psig FS = 1.4 Transport Vibration No loss of containment, no loss of packaging effectiveness 10CFR71.71(5)

N/A Package is acceptable Water Spray No effect on packaging effectiveness 10CFR71.71(6)

N/A Package is acceptable Normal Condition Free Drop No effect on packaging effectiveness 10CFR71.71(7)

N/A Package is acceptable Compression 623 psi 10CFR71.71(9) steel yield strength FS = 25.7 Penetration No effect on packaging effectiveness 10CFR71.71(9)

N/A Package is acceptable Hypothetical Accident Condition Free Drop and Puncture Drop No effect on packaging effectiveness 10CFR71.73(1) and (3)

N/A Package is acceptable Hypothetical Accident Condition Fire Maximum payload vessel temperature 429°F 10CFR71.73(4)

Maximum allowable payload/seal temperature = 500°F DM = 71 °F FS = 1.16 Fissile Immersion No in-leakage 10CFR71.73(5)

N/A Immersion No in-leakage 10CFR71.73(6)

N/A Notes on Table 2-1:

1. The Factor of Safety is defined as the ratio of the allowable to the actual, rounded down the nearest tenth.
2. The Design Margin is defined as the allowable minus the actual.

Docket No. 71-9342 Versa-Pac Safety Analysis Report Rev 8, May 2015 2-28 2.13.1 Appendix 2.13.1 MACTEC Report on Material Compatibility

Docket No. 71-9342 Versa-Pac Safety Analysis Report Rev 8, May 2015 2-29

Docket No. 71-9342 Versa-Pac Safety Analysis Report Rev 8, May 2015 2-30 2.13.2 Appendix 2.13.2 Performance Test Report for the Versa-Pac 133 pages: Issued under separate cover letter

Docket No. 71-9342 Versa-Pac Safety Analysis Report Rev 8, May 2015 2-31 2.13.3 Appendix 2.13.3 Excerpts from Safety Analysis Report for the Century Champion Type B Package Immersion Test Introduction The Century Industries Versa-Pac Shipping Package is an evolutionary package design based on the design and testing of the Century Industries Champion Type B package. Due to the similarity in both package designs, tests involving the Century Industries Champion, although not directly applicable, can be used to support the safety basis of the Versa-Pac design as supplemented by further analysis and tests. Tests involving the Champion package that are applicable to the design of the Versa-Pac include drop tests, thermal and immersion tests. The design similarities are further presented with attachment of the test results for the Champion package.

Design Comparison Both packages share the same basic structural components in that they have an inner and outer liner of sheet metal that is surrounded by vertical and horizontal stiffeners. Both package designs use the same ceramic fiber blanket insulation between the inner and outer liners and also surrounding the radial portion of the containment boundary. Both designs have approximately the same polyurethane foam in their respective bottom and top portions of the container. Both designs are based on an inner structure that slides into an outer drum. Therefore, both package designs should have a similar thermal response including thermal stresses. However, the temperature profiles may be different as further discussed.

The package designs differ in the type of insulation that surrounds the inner containment area.

The Champion surrounds the containment area with polyurethane foam that is poured in place while the Versa-Pac utilizes ceramic fiber blanket insulation within the same area.

The Champion utilizes a leak testable inner vessel as the primary containment with a secondary blind cap flange on top of the main sealing flange while the Versa-Pac uses only a 1/2 blind flange with a high temperature fibrous sleeve at the containment boundary.

Immersion Test Figure 2.13.3-1 shows the Century Champion Package rigging post-thermal test. Figure 2.13.3-2 displays the package being loaded into the pressure chamber. Figure 2.13.3-3 displays the package during the immersion testing.

Summary of Results Pages 15 and 16 of the Champion Safety Analysis Report are provided as Figures 2.13.3-3 and 2.13.3-4. The test results indicate that immersion testing of a damaged prototype package to a pressure of 23.0 +/- 1.0 psig during a 15-minute produce no additional damage.

Docket No. 71-9342 Versa-Pac Safety Analysis Report Rev 8, May 2015 2-32 Figure 2.13.3-1 Champion Package on Test Stand Figure 2.13.3-2 Champion Package During Immersion Testing Phase

Docket No. 71-9342 Versa-Pac Safety Analysis Report Rev 8, May 2015 2-33 Figure 2.13.3-3 Champion Package During Immersion Test

Docket No. 71-9342 Versa-Pac Safety Analysis Report Rev 8, May 2015 2-34 Figure 2.13.3-4 Champion Safety Analysis Report Page 15

Docket No. 71-9342 Versa-Pac Safety Analysis Report Rev 8, May 2015 2-35 Figure 2.13.3-5 Champion Safety Analysis Report Page 16

Docket No. 71-9342 Versa-Pac Safety Analysis Report Rev 8, May 2015 2-36 2.13.4 Appendix 2.13.4 Test Report for the VP-55 Versa-Pac Shipping Package (Shallow Angle Drops) 61 pages: Issued under separate cover letter

Docket No. 71-9342 Versa-Pac Safety Analysis Report Rev 8, May 2015 2-37 2.13.5 Appendix 2.13.5 NCT Versa-Pac Test Report for Compression &

Penetration 16 pages: Issued under separate cover letter

Docket No. 71-9342 Versa-Pac Safety Analysis Report Rev 10, March 2018 2-38 2.13.6 Appendix 2.13.6 Performance Test Report for the VP-55 5-Inch Pipe Container 44 pages: Submitted as separate document

Docket No. 71-9342 Versa-Pac Safety Analysis Report Rev 10, March 2018 2-39 2.13.7 Appendix 2.13.7 55 Gallon Versa-Pac Drop Test Deformation Measurement Report 23 pages: Submitted as separate document