Forwards Measured Leakage Rates for Sys Outside Containment Likely to Contain Radioactive Matl,In Response to NUREG-0578,Item 2.1.6.a
ML18085A989
Person / Time
Site: Salem 
Issue date: 03/02/1981
From: Mittl R
Public Service Enterprise Group
To: Varga S
Office of Nuclear Reactor Regulation
References
RTR-NUREG-0578, RTR-NUREG-578 NUDOCS 8103050208
Download: ML18085A989 (3)


Text

'~*

PStiG

  • Public Service Electric and Gas Company 80 Park Plaza Newark, N.J. 07101 Phone 201/430-7000 March 2~ 1981 Director of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Attention:

Mr. s. A. Varga, Chief Operating Reactors Branch 1 Division of Licensing Gentlemen:

LEAKAGE REDUCTION PROGRAM NO. 1 UNIT SALEM NUCLEAR GENERATING STATION DOCKET NO. 50-272 t:!

---i

~~*:.:~ ~-.~ \\~~~

,.
;,_ c:' _ _.

.:*2:::.i.:4 t~~u-..(:U

~\\T'."1

.o
0 1'l1

,(d;>

PSE&G hereby submits~ in the enclosure to this letter, mea-sured leakage rates for those systems outside containment likely to contain radioactive material~ as described in our letter dated July 8, 1980~ addressing NUREG-0578, Item 2.1.6.a.

Should you have any questions in this.regard; do not hesi-tate to contact us.

Attach CC:

Mr. Leif Norrholm Senior Resident Inspector s 1 oao so :ios The Energy People FR17/l p

Rf;;;z R. L. Mittl General Manager -

Licensing and Environment 95-0942

ENCLOSURE MEASURED LEAKAGE OF SYSTEMS

1.

Containment Spray System - only the portion which would have direct contact with the RHR system from the isolation valve to the containment building.

Leakage:

No leakage observed.

2.

CVC System -

the operational portion of the system which includes the letdown hea~ exchanger lines, seal water heat exchangers centrifugal charging pumps, and lines to and from the volume control tank.

.Leakage:

Total of 120 drops/minute observed *

. 3.

  • The RHR System -

the entire system except the 14 inch pipe from the containment sumpi* to the suction of the RHR pumps. which was examined under a static head pressure.

Leakage:

Total of 4 drops/minute observed.

4.

Reactor Coolant Sampling - all sample lines which have direct contact with the primary systems.

Leakage:

Total of 65 drops/minute observed.

5.

The Safety Injection System - all portions of the system which have direct contact with the containment building.

Leakage:

Total of 73 drops/minute observed.

FR17/2

r 6.

Liquid Radwaste System -

the waste evaporator and the waste holdup tanks.

Leakage:

No leakage observed.

7.

Waste Gas System -

the entire system except for the lines to and from the nitrogen supply portion of the system.

Leakage:

a)

For compressors and piping system at 53.2 FR17/3 psia -

10,830 SCCM.

b)

For the four (4).Waste Gase{ Decay Tanks at approximately 110 psia -

1,404.53 SCCM.

c)

Total leakage -

12,234.53 S~CM.

!