05000311/LER-1980-022-03, /03L-0:on 800731,jacket Water Heater Developed Leak Which Caused Jacket Water Heater for 2A Diesel to Trip. Caused by Equipment Failure.Heater Replaced.Design Change Issued for Different Type Heater

From kanterella
(Redirected from ML18082B102)
Jump to navigation Jump to search
/03L-0:on 800731,jacket Water Heater Developed Leak Which Caused Jacket Water Heater for 2A Diesel to Trip. Caused by Equipment Failure.Heater Replaced.Design Change Issued for Different Type Heater
ML18082B102
Person / Time
Site: Salem 
Issue date: 08/28/1980
From: Newman R
Public Service Enterprise Group
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML18082B101 List:
References
LER-80-022-03L-01, LER-80-22-3L-1, NUDOCS 8009090558
Download: ML18082B102 (1)


LER-1980-022, /03L-0:on 800731,jacket Water Heater Developed Leak Which Caused Jacket Water Heater for 2A Diesel to Trip. Caused by Equipment Failure.Heater Replaced.Design Change Issued for Different Type Heater
Event date:
Report date:
3111980022R03 - NRC Website

text

,

_ ~" ~ONTROL BLOCK:

.._I _.....____._....___.

1 rn 'i N, J, s, G 1 s 12 10 o

7 8

9 i.:1ceNSEE COOE 14 15 0

!PLEASE PRINT OR TYP~L REQUIRED INFORMATIDNI o

o o

o o

o 01 ~

l I l I 11 1101 I I 0 LICENSE NUMBER 25 26 LICENSE TYPE

JO 57 CAT 58 CON'T [TITI
~~~~~ L1JG) I o I 5 I o I o I o I 3 I 1 I 1 101 o I 1 I 3 I 1 I 8 o KV I o I a I 2 I a I a Io 10
7.

B 60 61 DOCKET NUMBER 68 69 EVENT DATE 74 75 REPORT DATE 80 EVENT DESCRIPTION AND PROBABLE CONSEQUENCES@

[]JI] I Upon receipt of a diesel trouble alarm, it was found that the jacket water I

[IT[]

[ill]

[ill]

[))))

[TI2J

[))))

heater breaker had tripped and would riot reset.

Further investigation revealed that the heater was leaking.

Action Statement 3.8.l.lb was entered at 1400 hours0.0162 days <br />0.389 hours <br />0.00231 weeks <br />5.327e-4 months <br />.I (Docket 50-272, 76-12, 77-59, 77-77, 77-80; Docket 50-311, 80-02}

7 8 9 80 r:£:IIl 7

8 SYSTEM CODE IE I El@

9 10

(.;\\ LEA RO CVENT YE.AR

\\:..:..; REPORT I 8 I 0 I

!\\;Ull!.BER 2*1 22 ACTIOI\\:

FUTURE TAKEt.;

ACTION EFFECT ON PLANT

CAUSE

CAUSE CODE SUBCODE COMl?ONENT CODE l!J@ ~@ IE IN I GI I IN IE. I@

11 12 13 18 SEQUENTIAL OCCURRENCE REPORT NO.

CODE l=J 1012121 IOl31 COMP.

SUBCODE t.:J 19 REPORT TYPE L2J VALVE SUBCODE L:J@

20 1=J 23 24 26 27 28 29 30 31 SHUTDOWN METHOD r:;::;..

ATTACHMENT NPR0-4 PRIME COMP.

SUPPLIER REVISl 00N NO.

~

32 COMPONENT MANUFACTURER HOURS ~ SUBMITTED FORM ~UB.

lliJ@LLl@

ILJ@

LIJ@

I o Io I o I o I W@ L!J@

33 34 35 36 3 7 40 41 42

~ I c 13 1 2 12 I@

43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS

(([§] I The defective heater was replaced, tested satisfactorily and the Action Statement was terminated at 1335 hours0.0155 days <br />0.371 hours <br />0.00221 weeks <br />5.079675e-4 months <br /> on August 1, 1980.

A Design Change has been issued to install a different type heater and the parts have been ordered.

[IE]

8 9

FACILITY IJQ\\

STATUS

%POW~R OTHERSTATUS ~

, [2JI] W@ I 0 I 0 I 0 l@)L-1 --=NA.;.__........J 80 METHOD OF A

DISCOVERY DISCOVERY DE.SCRIPTION ~

L!.J(22)~1 ________ o~p=-e_r_a_t_o_r_o_b_s_e_r_v_a

___ t_i_o_n ___________ ~

  • 7 8

9 10 12 11 ACTIVITY CONTENT Q'\\

REI.EASED OF REI.EASE AMOUNT OF ACTIVITY~

[ill] W@ Ll.J@I NA 7

8 9

10 11 45 46 44 80 LOCATION OF RELEASE @

44 45 NA 80 PERSONNEL E'XPOSURES r::;:;..

NUMBER A

TYPE DESCRIPTION~

ITDJ *I ol ol olLJJ@~_N=A..:..-_..*-----------------------J 7

. 8 9

11

. 12 13 80 PERSONNEL INJURIES

(.;:;'\\

NUMBER DESCRIPTION~

[QTI I d ol cl@)~_N=A..:..--------------------------.-:..----J 7

8 9

11 12 80 LOSS OF OR DAMAGE TO FACILITY 143\\

TYPE

DESCRIPTION

\\:::.;J

  • EEJ W@

NA 7

8 9

~10~--===------------------------------------------1 PUBLICITY

(.;:\\

SO ISSUEDc:;\\ DESCRIPTION \\!V NRC USE ON Ly

lII9J W6 I I I I I I I I I I I I I ~.

a 91

~o-.-~~---------------------..:... ___________________ __J6B 69 80 ;;

E OF R. J. Newman NAM PREPA.RER -~.,,.....,,,,,...,,,,.....,,,-,:-~--::::::-~=--------

{j))(W09@9 (} s--t) 1 PHONE: _6_0_9_-_9_3_5_-_o_9_9_a ____ _

0 a.