05000311/LER-1980-024-03, /03L-0:on 800801,while Withdrawing Rods in Preparation for Entering Mode 2,position Indicator Read 20 Steps Lower than Bank Demand Position.Caused by Equipment Failure.Individual Rod Position Indicator Replaced

From kanterella
(Redirected from ML18082B096)
Jump to navigation Jump to search
/03L-0:on 800801,while Withdrawing Rods in Preparation for Entering Mode 2,position Indicator Read 20 Steps Lower than Bank Demand Position.Caused by Equipment Failure.Individual Rod Position Indicator Replaced
ML18082B096
Person / Time
Site: Salem 
Issue date: 08/28/1980
From: Newman R
Public Service Enterprise Group
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML18082B037 List:
References
LER-80-024-03L-01, LER-80-24-3L-1, NUDOCS 8009090455
Download: ML18082B096 (1)


LER-1980-024, /03L-0:on 800801,while Withdrawing Rods in Preparation for Entering Mode 2,position Indicator Read 20 Steps Lower than Bank Demand Position.Caused by Equipment Failure.Individual Rod Position Indicator Replaced
Event date:
Report date:
3111980024R03 - NRC Website

text

- LICENSEE EVENT HEPOHT CONTROL BLOCK: !-1_,___.__.__..... l=-_._--!l8 1

6 (PLEASE PRINT OR TY-L REQUIRED INFORMATIONI rn 1 N, J 1 s, G, s 1 2 10 1 o, o 1 -1 o, o 1 o 1 o, o, - 1 o 1 o 101 4 1 1 1 1 1 i 1 i 10 1 1 1 0 7

8 9

LICENSEE CODE 14 15 LICENSE NUMBER 25 26

  • LICENSE TYPE

~O 57 CAT 5B CON'T

!:IE]

7 8

((ill

[))I]

[ill]

C2::ITJ [ill]

[TIIJ

(]TI]

~~~~~ L!J©I ol s I ol o I o I 3 I i I i 101 o I 8 Io 11 18 I 0 IG)lo I s 12 I s Is I a IG) 60 61 DOCKET NUMBER 68 69 EVENT DATE 74 75
  • REPORT DATE 80 EVENT DESCRIPTION ANO PROBABLE CONSEQUENCES@

I While withdrawing rods in preparation for entering Mode 2, 1SC2 individual rod position indicator read 20 steps lower than the bank demand position.

Action Statement 3.1.3.2.2 was entered at 1300 hours0.015 days <br />0.361 hours <br />0.00215 weeks <br />4.9465e-4 months <br />.

(Docket 50-272, 77-87, 79-05) 7 8 9

~

7 8

SYSTEM CODE I RI Bl@

9 10

/;:;\\

LE c:i "lO c*VE!IOT YE-' R l.:..Y REPORT l 8 I 0 I

Ur.!.BER 2*1 22

CAUSE

CAUSE CODE SUB CODE COMPONENT CODE

~@) ~@ rl NI sl Tl RI u1~

11 12 13 1B SEQUENTIAL OCCURRENCE REPORT NO.

CODE I

I Io 12 I 4 I I......-1 I o I 3 I 23 24 26 2 7 28 29 CQ*l.P:

SUBCODE LU 19 REPORT TYPE L!j JO VALVE SUBCODE

~@

20 l.=l 31 RE.VISION NO.

~

32 80 ACTION FUTURE EFFECT SHUTDOWN r::::;...

ATTACHMENT NPR0-4 TAKEr.;

ACTION ON PLANT METHOD HOURS ~ SUBMITTED FORM ~UB.

PRIME COMP.

SUPPLIER COMPONENT MANUFACTUREF'

~@~@ ~@ ~ I 01 01 01 01

~@ ~@)

33 34 35 36 37 40 41 42 l::.J@

I BI 0 I 4 1 5 1@

CAUSE DESCRIPTION AND CORRECTIVE ACTIONS @

43 44

47.

I The individual rod position indicator meter movement was replaced with a snare.

The indicator was retested and returned to service.

The Action Statement was o::m ITIIJ [IE) 7 8

g FACILITY terminated at 2335 hours0.027 days <br />0.649 hours <br />0.00386 weeks <br />8.884675e-4 months <br />.

STATUS

%POWER OTHER STATUS GTIJ LU I 0 I 0 I 0 l@li---___

N_A_~

B 9

10 12 1'3 44 ACTIVITY CONTENT Q\\

RELEASED OF RELEASE A~OUNT OF ACTIVITY ~

OE w @ Ll.J@)I..... -'N"'"-A"---_____

7 8

g 10 11 44 PERSONNEL E'XPQSURES 0,

NUMBER A

TYPE

DESCRIPTION

METHOD OF r:;::;.,

DISCOVERY DISCOVERY DESCRIPTION ~

~~~'---Op~e_r_a_t_o_r~O_b_s_e_r_v a_t_i_o_n __ ~--~------------'

45 46 80 LOCATION OF RELEASE @

NA 45 80 CI:I2J I ol ol ok8LJI@

NA 7

8 9

11 12 1.3 __ __........_ _____ ~-~--~-~-~--~~~---~-~~~~~~-~---~--~--BO PERSONNEL INJURIES f,;";\\

NUMBER DESCRIPTION6 Ei:EJ cl ol oJ@)

NA 7

8 9

11

~12~-:.:::.:..-~~~~~~--~-~~~~~~--~--~---------~----~~--~~---8~0 LOSS OF OR DAMAGE TO FACILITY 143\\

TYPE

DESCRIPTION

\\::;J Em W@

  • NA 1

s 9

~10::--------------------------~----------------------------------------------------~~~/-~ao PUBLICITY

(.;-\\

ISSUED~ DESCRIPTION~

NRC USE ONL y IIliJ W6 N

I I I I I I I I I I I I I ~

1 a 91

"'"o _ __......._ ______________________________________________ -Jss ss BO Ci NAMEOFPREPARER~ ______

R_._._J_. __ N_e_wm

__ a_n ________________ _

PHONE:-6_0_9_-_9_3_5_-_0_9_9_8 ____ _

0 Q...,