05000311/LER-1980-017-03, /03L-0:on 800718,during Routine Operation, Auxiliary Feedwater Storage Tank Level Found Below Min Operating Level of 200,000 Gallons.Caused by Inlet Valve Being Throttled Too Far.Level Restored

From kanterella
(Redirected from ML18082A906)
Jump to navigation Jump to search
/03L-0:on 800718,during Routine Operation, Auxiliary Feedwater Storage Tank Level Found Below Min Operating Level of 200,000 Gallons.Caused by Inlet Valve Being Throttled Too Far.Level Restored
ML18082A906
Person / Time
Site: Salem 
Issue date: 08/12/1980
From: Murphy M
Public Service Enterprise Group
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML18082A905 List:
References
LER-80-017-03L, LER-80-17-3L, NUDOCS 8008180459
Download: ML18082A906 (1)


LER-1980-017, /03L-0:on 800718,during Routine Operation, Auxiliary Feedwater Storage Tank Level Found Below Min Operating Level of 200,000 Gallons.Caused by Inlet Valve Being Throttled Too Far.Level Restored
Event date:
Report date:
3111980017R03 - NRC Website

text

{7-77)

LICENSEE EVENT REPORT CC!:INTRO~ BLOCK:._I _...___.._...__....l_._...__.10 (PLEASE PRIN_T OR TYP. REQUIRED INFORM.ATIONI 1

6 1 o 1, r 1 N. 1 J 1 s 1 G 1 s 12 101 o 1 o 1 -1 o 1 o 1 o 1 o 1 o 1 -1 o 1 o 101 4 1 l I l I l I 1101 1 -, 0 7

8 9

LICENSEE CODE 14 15 LICENSE NUMBER 25 26 LICENSE TYPE JO 57 CAT 58 CON'T Io I, I

g~~~~ LJJG)I al s I o I o I o I 3 I i I i IG)I o I 1 11 I 0 I 0 I o l©I o I a I i I 2 I a I 7
8.

60 61 DOCKET NUMBER 68 69 EVENT OATE 74 75 REPORT DATE EVENT DESCRIPTION ANO PROBABLE CONSEQUENCES@

ol© 80 I o I 2 I._l_D_ur_in__,g::..-r_o_u_t_i_* n_e_o....:p=-e_r_a_t_i_* o_n_.:.., _i_t_w_a_s_d_e_t_e_rm_i_n_e_d~t_h_e_A_u_x_i_l_i_a_ry-=-_F_e_e_d_w_a_t_e_r_s_t_or_a..::.g_e _____

......J

[§Jil I Tank level fell below the minimum operating level of 200, 000 gallons at 0708. hours lQJlJ I and Action Statement 3.7.1.3 was entered (Docket 50-272, #78-40).

(]:((]..._ ______________________________________________________________________ --1

[))))

ITIIJ

[)))) '-----------------------------------------------------------------------------'

7 8 9 [ill]

7 s.

SVSTM CODE I WIF I@

9 10 I:'::\\

LE R/RO LVENT YEAR

~

REPORT I 8 I 0 I NUMBER 21 22

CAUSE

CAUSE COMP.

CODE SUBCODE COMPONENT CODE SUBCODE

~@ ~@) jA.jc I Cl VI Ml v1@ ILJ@

11 12 13 18 19 SEQUENTIAL OCCUR REN CE REPORT REPORT NO.

CODE TYPE VALVE SUBCOOE w@

20 I

I Io 11 11 I 1.......-1 I 01 3 I

~ l=1 23 24 26 27 2B 29 30 31 REVISION NO.

l::J 32 80 ACTION FUTURE TAKEN

- ACTION EFFECT SHUTDOWN

/,;::;..

ATTACHMENT NPRD-4 PRIME COMP.

ON P.LANT METHOD HOURS ~ SU6MITTEO

~ORM :.US.

SUf'f'LIER W@W@ L!J@ W t 0101010 I L!J@

L!J@ ~

COMPONENT MANUFACTURER 33 34 35 36 37 40 41 42 43 IX I 91 91 91@)

CAUSE DESCRIPTION AND CORRECTIVE ACTIONS @

44 47 LiliJ I The inlet valve was throttled too far while making up water to the Steam Generators O']J] I from the tank, thereby causing the level to decrease too far.

The level was restored OTil and the Action Statement was terminated at 0731 hours0.00846 days <br />0.203 hours <br />0.00121 weeks <br />2.781455e-4 months <br />.

tLW 1

a 9 FACILITY*

STATUS

% POWER

,,..... 1 s-1. ~@ I o I o I o l@)I I

7 8.. 9*

10 12 1'3--------44~

ACTIVl-TY CONTENT Q\\

REL.CASED OF RELEASE AMOUNT OF ACTIVITY ~

DID. w @ Ll.1@~1 _.;NA__.._ _______ ___

7

  • 8. 9 10*

11 OTHER STATUS @

NA 80 METHOD OF t:;::;\\

DISCOVERY DISCOVERY DESCRIPTION ~

L!.JGJ)~l ___

0p;:;_e_r_a_t_o_r_o_b_s_e_r_v_a_:t_i_o_n ________ --1 45 46 80 LOCATION OF RELEASE @

45 NA 80 PERSONNEL EXPOSURES

~

NUMBER A

TYPE DESCRIPTION~

IJTIJ I ol ol olU@

NA 1

a 9

11 12 1~3--------------------------------------a-'o PERSONNEL INJURIES I,;":;\\

NUMBER DESCRIPTION6 0171 I cl ol ol@

NA 1

a 9

11

~12~~=-------------------------------------~eo LOSS OF OR DAMAGE TO FACILITY f4:i\\

TYPE

DESCRIPTION

l\\:;I EEJ W@~~NA

.....;......i 7

8*

9 10

@()

PUBLIClTY C\\

. ISSUED~ DESCRIPT. ION~

NRC: USE ONL y ITJ:0J W6~-~------------------_;_i I I II I II I II II I !

7 8 080'8 1 so°'l5C/.

68 69 so ~.

NAM~ OF PREPARER _____

M_._J_. __

Mur_.-P_h_y_______

PHONE:-_6_0_9_-_9_3_5_-_0_9_9_8_____

~