PS~G e-Public Service Electric and Gas Company 80 Park Place Newark. N.J. 07.101 Phone 201/430-7000 Mr. Boyce H. Grier Director of USNRC August 12, 1980 Off ice of Inspection and Enforcement Region 1 631 Park Avenue King of Prussia, Pennsylvania 19406

Dear Mr. Grier :

LICENSE NO. DPR-75 DOCKET NO. 50-311 REPORTABLE OCCURRENCE_ 20-16/03L Pursuant to the requirements of Salem Generating Station Unit No. 2 Technical Specifications, Section 6.9.1, we are submitting Licensee Event Report for Reportable Occurrence 80-16/03L.

This report is required within thirty (30) days of the occurrence.

Sincerely yours,

- f. e -f *n~..

F.P.~~

General Manager -

Electric Production CC:

Director, Office of Inspection and Enforcement (30 copies)

Director, Office of Management Information and Program Control (3 copies) oc no 1

lone o

~o

Report Number:

Report Date:

Occurrence Date:

Facility:

80-16"3L 8/12/80 7 /16/80 Salem Generating Station,. Unit 2 Public Service Electric & Gas Company Hancock's B.i::-idge, New Jersey 08 038 IDENTIFICATION OF OCCURRENCE:

Safety Valve Improperly Set CONDITIONS PRIOR TO OCCURRENCE:

Mode 4 Prior to Initial Criticality DESCRIPTION OF OCCURRENCE:

In reviewing the calibration records for the safety valves, 2PR3, 4 and 5, it was determined the valves were not set by the vendor at ambient conditions of the valve at nominal operating temperature ana pressure as required by Action Statement 3.4.3.

A discussion with the vendor ensued and it was determined the accuracy of the valves settings would be within the allowable tolerance when comparing test conditions to operating conditions.

Based on the above discussions, a mode change to Mode 3 was allowed.

As part of a routine.inspection, the Resident NRC Inspector determined the valve setting was questionable and requested the valves be retested as soon as possible.

Upon retest by Public Service Electric and Gas, it was found 2PR4 and 5 were out of specification.

DESIGNATION OF APPARENT CAUSE OF OCCURRENCE:

Procedural Inadequacy ANALYSIS OF OCCURRENCE:

The initial review of the Technical Specification requirement did not identify the difference between Unit 1 and Unit 2 requirements.

Unit 1 does not require the testing and setting of the safety valves at ambient conditions of the valve at nominal operating temperature and pressure.

CORRECTIVE ACTION

The valves were tested and reset properly while installed in the system and the procedure has been changed to ensure the test ambient conditions are proper to comply with Technical Specifications.

'LER 80-16/03L 2 -

FAILURE DA':):'A:

Not Applicable Prepared By M. J. Murphy SORC Meeting No.

61-80