05000311/LER-1980-008-03, /03L-0:on 800710,during Routine Containment Entries,Entry Into Action Statement 3.6.1.3 Resulted from Excessive Leak Rate.Caused by Gaskets Being Moved from Seating Surface Due to Improper Operation.Gaskets Reseated

From kanterella
(Redirected from ML18082A877)
Jump to navigation Jump to search
/03L-0:on 800710,during Routine Containment Entries,Entry Into Action Statement 3.6.1.3 Resulted from Excessive Leak Rate.Caused by Gaskets Being Moved from Seating Surface Due to Improper Operation.Gaskets Reseated
ML18082A877
Person / Time
Site: Salem 
Issue date: 08/08/1980
From: Murphy M
Public Service Enterprise Group
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML18082A875 List:
References
LER-80-008-03L-01, LER-80-8-3L-1, NUDOCS 8008140314
Download: ML18082A877 (1)


LER-1980-008, /03L-0:on 800710,during Routine Containment Entries,Entry Into Action Statement 3.6.1.3 Resulted from Excessive Leak Rate.Caused by Gaskets Being Moved from Seating Surface Due to Improper Operation.Gaskets Reseated
Event date:
Report date:
3111980008R03 - NRC Website

text

(7-77)

(>..

LICENSEE EVENT REPORT

, CONTROL BLOCK: I f. I Ii" (PLEASE PRINT OR TYPE. REQUIRED INFORMATION)

~1~.&....-'-~.&....-'-----.!6\\..!./

~IN IJ Is JG Is 12 101 ol ol -I ol ol.ol ol ol -1 ol olG)l 41 ll ll ll ll@I I 10 7

B 9

LICENSEE CODE 14 15 LICENSE NUMBER 25 26 LICENSE TYPE JO 57 CAT 58 CON'T lTIIJ 7

B

~~~~~ LJJ©I ol sl ol of of 3f 1l 1GI 011111010101G)101 Blol BIB I olG) 60 61 DOCKET NUMBER 68 69 EVENT DATE 74 75 REPORT DATE BO EVENT DESCRIPTION AND PROBABLE CONSEQUENCES@

(())] I During routine containment entries, the gaskets for the containment

((nJ I air locks were moved out of their seating surface resulting in an CITIJ [ffi]

(())]

[]JI}

[ill]

excessive leak rate and a required entry into action statement 3.6.1.3 on July 10, 11, 12, 14 and 16.

(Docket 50-272, 77-SB, 77-70, 77-73, 78-2B, 7B-56, 78-75) 7 B 9 rr:m 7

B SYSTEM CODE I SIAI@

. 9 10

{';:;\\

LER'RO LVENT YEAR

\\!:) REPORT I 8 I 0 I NUMBER 2,..

22

CAUSE

CAUSE COMP.

VALVE CODE SUBCODE COMPONENT CODE SUBCODE SUBCODE

~@ l£..J@) IPIEIN IEITIRI@ ~ l!J@

11 12 13.

18 19 20 SEQUENTIAL OCCURRENCE REPORT REPORT NO.

CODE TYPE I I 10101u

~ 10131

~ 1=J 23 24 26 27 28 29 30 31 ACTION FUTURE TAKEN ACTION EFFECT SHUTDOWN

~

ATTACHMENT NPRD-4 PRIME C:OMP.

REVISION NO.

LQJ 32 COMPONENT MANUFACTURER 80 ON PLANT METHOD HOURS ~ SUBMITTED FORM SUB.

SUPPLIER llLJ@L!LJ@) W l!..J 101010101 L!..J@ W ~@

33 34 35 36 37 40 41 42 43 I c I 3111 o I@

CAUSE DESCRIPTION AND CORRECTIVE ACTIONS @

44 47 OI[J I The excessive leak rate was caused by the gasket being moved from its seating surface due to improper operation.

In each case, the gasket was reseated, tested satisfactorily and the action statement terminatedi o::ID I Personnel training will be conducted to ensure proper operation.

[ill]

7 B

9 FACILITY tjQ\\

STATUS

% POWER OTHER STATUS ~

[ITIJ W@ lo I o lo l@I N/A I

7 B 9 10 12

"'"n ___

_.44 ACTIVITY CONTENT

(:;;;\\

RELEASED OF RELEASE AMOUNT OF ACTIVITY ETIJ W@ LIJ@.... I...-N=A"-*-------i 7

B 9

10 11 PERSONNEL EXPOSURES t:;;::..,

METHOD OF

~

DISCOVERY DISCOVERY DESCRIPTION '231 L!JQD~l_R~o_u_t_i_n_e~S_u_r_v_e~i_l_l_a_n_c_e ____________ __,

45 46 LOCATION OF RELEASE @

NA 45 80 80 80 NUMBER

. ~TYPE

DESCRIPTION

DTIJ I a ol ol(0L.zJ~.....o=.A,___ ____________________ ___,

7 B 9 11 12 13 PERSONNEL INJURIES

/,;";'\\

NUMBER DESCRIPTION6 80 rrm I q ol ol@

A 7

B 9

11

~12~"""""'0:.:....~--------------------------------------8~0 LOSS OF OR DAMAGE TO FACILITY l,i3' TYPE

DESCRIPTION

~

  • EEJ W@

NA 7

B 9

~10:------....--------------------------~---------------~8~0 PUBLICITY Q.

NRC USE ONLY ISSUED(,;';\\ DESCRIPTION~

.IIEJ l.Ji.J~~---'1------------------------------------------------------------'

I I I I I I I I I I I I I~

7 B

9 10 68 69 80 ;

0 II PHONE :_6_0_9_-_9_3_S_-_0_9_9_B ____ _

8 Q 0 8 1 4 0 Jill O'F PREPARER M.J.

Murphy