COL Docs - Icn and Uin Comment Status Sheet for Future Public Meeting
ML18081A219
Person / Time
Site: Vogtle  
Issue date: 03/22/2018
From:
NRC
To:
NRC/NRO/DNRL/LB4
References
Download: ML18081A219 (4)


Text

1 Vogtle PEmails From:

Hoellman, Jordan Sent:

Thursday, March 22, 2018 10:39 AM To:

Vogtle PEmails

Subject:

ICN and UIN Comment Status Sheet for Future Public Meeting Attachments:

UIN ICN comment status sheet for March 22.docx Please see the attached ICN and UIN Comment Status Sheet for discussion at a future public meeting with SNC regarding licensing actions at Vogtle Units 3 and 4.

Hearing Identifier:

Vogtle_COL_Docs_Public Email Number:

238 Mail Envelope Properties (SN6PR09MB2608E7ADF6FD8DC1DD75EDB5D5A90)

Subject:

ICN and UIN Comment Status Sheet for Future Public Meeting Sent Date:

3/22/2018 10:39:00 AM Received Date:

3/22/2018 10:39:04 AM From:

Hoellman, Jordan Created By:

Jordan.Hoellman2@nrc.gov Recipients:

"Vogtle PEmails" <Vogtle.PEmails@nrc.gov>

Tracking Status: None Post Office:

SN6PR09MB2608.namprd09.prod.outlook.com Files Size Date & Time MESSAGE 167 3/22/2018 10:39:04 AM UIN ICN comment status sheet for March 22.docx 27101 Options Priority:

Standard Return Notification:

No Reply Requested:

No Sensitivity:

Normal Expiration Date:

Recipients Received:

1 VOGTLE ICN/UIN ISSUES TRACKING SHEET Date ITEM #

ICN UIN TOPIC ITAAC INDEX ISSUE Licensee Comment 3/20 1

UIN Component hydrostatic test 459, 72, 91, 13, 220, 120, 431 and DRAFT 159 These UINs credit completion of the ITAAC for hydrostatic testing of the ASME Section III components listed in the various tables using the vendors hydrostatic test of the components. The staff previously rejected the ICNs submitted by SNC that credited completion of this ITAAC by using the ASME required vendor hydrostatic test of the components. These ITAAC are for the as-built system hydrostatic test required by the code prior to placing the system in service.

3/20 2

UIN RCS design and constructed 13 The staff wants to understand the purpose of the note below Table Attachment B. UFSAR Section 5.2.1.1 is applicable to all RCPB components and piping. Therefore, the note below Table Attachment B is confusing as it appears to be pertaining only to RCS-L069A/B. In addition, the structure of the note also appears to imply that the 1989 Addenda to the 1989 Edition of the ASME Section III Code can be used for socket welded connections, which is contradictory to UFSAR Section 5.2.1.1

2 3/20 3

UIN Functional capability DRAFT 159 The Tier 1 definition of inspection includes inspections of reports/documents. The ITAACs acceptance criteria requires that a report exists and conclude the piping maintains functional capability. The IDB is clear the inspection was of a report based on the as-built piping system following its inspection and reconciliation with design requirements.

Accordingly, this satisfies the requirements of the ITA and AC.

SNC noted the ITA for ITAAC 159 is different from the other ITAAC for piping functional capability.

ITAAC 159 specifies an inspection will be performed verifying functional capability while the other ITAAC for functional capability specify an inspection will be performed for the existence of a report verifying functional capability.

3/21 4

UIN Environme ntal Qualificati on 98 The completion description for part 6d.i (non class 1E section) does not reference the USFAR like the class 1E section does, and like the other UINs for harsh EQ. We have previously indicated the need to provide the reference to where in the UFSAR the qualification info is located.