Text

  • AVERAGE DAILY UNIT POWER LEVEL DOCKET NO gQ-255 UNIT Psilil!S!Qes DATE Qf!lQJl97 COMPLETED BY ~A~Qbisitsi MONTH May TELEPHONE!f!16l764-2572 AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe Net) (MWe Net)
1. 771 17. 771
2. 772 18. lf!f!
3. 711 19. lfi9
4. 772 20. 77J
5. 768 21. 772
6. 111 22. 772
7. 771 23. 171 8 .. 768 24. 766
9. 771 25. 767
10. 712 26. 771
11. 769. 27. 171
12. 712 28. 7f!8
13. 713 29. 7§§
14. 77Q 30. 1§6
15. 772 31. 1§8
16. 771 INSTRUCTIONS:

On this format, list the average daily unit power level in MWe-NET for each day in the reporting month. Compute to the nearest whole megawatt.

9706090229 970603 - .~*1 ADOCK 05000255i .

.PDR R -. ----- - * -- PDR; - --! -- - - - - --- -

---~

, - ... ¥*.

./

SUMMARY

OF OPERATING EXPERIENCE FOR MAY 1997 The Unit operated at 100 percent power the entire month .

REPORT MONTH MAY 1997 DOCKET NO 50-255 UNIT Palisades DATE 06103191.

COMPLETED BY KAKobiata TELEPHONE 616-764-2572 UNIT SHUTDOWNS AND POWER REDUCTIONS No. Date Type 1 Duration (Hours)

Reason 2 Method of Shutting Down Reactor Licensee Event Report #

System Code 4 Component Code 5 Cause & Corrective Action to Prevent Recurrence NONE

1. 2. 3. 4. 5.

F: Forced Reason Method: Exhibit G - Instructions Exhibit I - Same Source S: Scheduled A-Equipment Failure (Explain) 1-Manual for Preparation of Data B-Maintenance or Test 2-Manual Scram Entry Sheets for Licensee C-Refueling 3-Automatic Scram Event Report (LER) File 0-Regulatory Restriction E-Operator Training & License Examination F-Administrative G-Operational Error (Explain) 4-0ther (Explain) (NUREG-0161)

H-Other (Explain)

  • OPERATING DATA REPORT DOCKET NO 50-255 DATE 6-2-97 COMPLETED BY KAKobiata TELEPHONE (616)764-2572 OPERATING STATUS:

NOTES:

l. UNIT NAME Palisades
2. REPORTING PERIOD: 970501-970531
3. LICENSED THERMAL POWER (MWt) 2530
4. NAMEPLATE RATING (GROSS MWe) 811. 7
5. DESIGN ELECTRICAL RATING (NET MWe) 805
6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWe) **110
7. MAXIMUM DEPENDABLE CAPACITY (NET MWe) **730
8. IF CHANGES OCCUR IN CAPCITY RATINGS (ITEM NUMBERS 3 THROUGH 7AND 7) SINCE LAST REPORT, GIVE REAS::lNS:
9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWe):
10. REASONS FOR RESTRICTIONS, IF ANY:

This Month Yr-to-Date Cumulative ll. HOURS IN REPORTING PERIOD 744.0 3623.0 223094.0

12. NUMBER OF HOURS REACTOR WAS CRITICAL 744.0 3097.2 131194 .4
13. REACTOR RESERVE SHUTDOWN HOURS
14. HOURS GENERATOR ON-LINE 744.0 2957.2 126182.7
15. UNIT RESERVE SHUTDOWN HOURS
16. GRO~S-THERMAL ENERGY GENERATED (MWH) 1874999.8 7185951.3 278789949.8
17. GROSS ELECTRICAL ENERGY GENERATED (MWH) 602085 2305768 88372503
18. NET ELECTRICAL ENERGY GENERATED (MWH) 572972 2191040 83458800
19. UNIT SERVICE FACTOR 100.0t 81. 6\ 56.6\
20. UNIT AVAILABILITY FACTOR 100.0t 81. 6\ 56.6\
21. UNIT CAPACITY FACTOR (USING MDC NET) 105.5\ 82.8\ 54.8\*
22. UNIT CAPACITY FACTOR (USING DER NET) 95.7\ 75.lt 46.5\
23. UNIT FORCED OUTAGJ:: RATE O.Ot 18.4\ 27.5\

24 .. SHUTDOWNS SCHEDULED OVER THE NEXT 6 MONTHS (TYPE, DATE AND DURATION OF EACH):

25. IF SHUTDOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF STARTUP:
26. UNITS IN TEST STATUS (PRIOR TO COMMERCIAL OPERATION):

Forecast Achieved INITIAL CRITICALITY INITIAL ELECTRICITY COMMERCIAL OPERATION Based on condenser backpressure

  • Weighted Average (635 MWe used as MDC Net prior to October 1985)