ML18059A978

From kanterella
Jump to navigation Jump to search
Confirms That Licensee Completed All Actions Requested by Bulletin 88-011, Pressurizer Surge Line Thermal Stratification, Ensuring That Plant Pressurizer Surge Line in Compliance W/Applicable Code Requirements
ML18059A978
Person / Time
Site: Palisades 
Issue date: 04/30/1994
From: Rogers D
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
IEB-88-011, IEB-88-11, NUDOCS 9405110298
Download: ML18059A978 (2)


Text

,.

I/* *.

consumers Power POWERING MICHIGAN'S PROGRESS Palisades Nuclear Plant:. 27780 Blue S~ar Memorial Highway, Covert, Ml 49043 April 30,

  • 1994 Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 David W. Rogers Plant Safety and Licensing Director DOCKET 50-255 - LICENSE DPR PALISADES PLANT - BULLETIN 88-11: PRESSURIZER SURGE LINE THERMAL STRATIFICATION - ADDITIONAL INFORMATION Consumers Power Company's November 22, 1993 letter described the actions we had compl~ted in response to requested action items I.a, l.b, I.c and I.d in NRC Bulletin No. 88-11, Pressurizer Surge Line Thermal Stratification. Our response to Action Item l.d was incomplete at that time because we were waiting for the completion of three Palisades plant specific design analyses being performed as Combustion Engineering Owner's Group tasks. Those CEOG tasks have been comp 1 eted and our response to action item I. d fo 11 ows:

NRC Request 1.d.

Based on the applicable plant specific or referenced data, licensees are requested to update their stress and fatigue analyses to ensure compliance with applicable Code requirements, incorporating any observations from 1.a above.

The analysis should be completed no later than two years after receipt of this bulletin. If a licensee is unable to show compli_ance with the applicable design codes and other FSAR and regulatory commitments, the licensee is requested to submit a justification for continued operation and a description if the proposed corrective actions for effecting long term resolution.

Compliance Status The update of the Palisades pressurizer surge line stress and fatigue analyses is part of three CEOG tasks. They are:

I.

CEOG Task 695 - Engineering specification for Primary Coola~t Pipe and Fittings for Consumers Power Company, Revision 2

- tngineering Specification for a Pressurizer Assembly*

Secification No.70 P - 001, Revision 3

2.

CEOG Task 696 - Consumers Power Surge Line Analysis for Thermal

~ ~ ~Q Loadings, Including Effects of Thermal Stratification 11 \\j 'v '- ***

9405110298 940430 PDR ADOCK 05000255 Q

PDR A CMS' ENERGY COMPANY I D

3.

CEOG Task 697 - Addendum to the Piping Analytical Report for C~nsumers Power Company Palisades Nuclear Plant

- Addendum to the Pressurizer Analytical Report. for Consumers Power Company Palisades Nuclear Plant Those CEOG Tasks are now complete.

The Palisades stress and fatigue analyses have been updated as follows:

I. The. design specifications for the pressurizer assembly and the primary coolant pipe and fittings have been re~ised as part of CEOG Task 695.

2.

The surge line piping has been analyzed as part of CEOG Task 696.

The piping responses to thermal.stratification loads have been incorporated into the piping design basis calculation.

3.

The pressurizer surge nozzle and surge line reactor coolant system nozzle have been analyzed as part of CEOG. 697..

This update ensures that the Palisades pressurizer surge line is in compliance with all applicable code ~equirements.. Our response to Action Item l.d of Bulletin 88-11 is now complete. This letter confirms that the Palisades Plant has completed all the actions requested by Bulletin* 88-11.

The NRC's September 13,1993 letter recommended that Palisades perform volumetric examination of critical elbow components in the pressurizer surge line as part of future ASME inservice inspections.

Our evaluation of the need to include this examination in the Paliiades inse~vic~ inspections is not complete.

When we complet~ that evaluation, we will inform the NRC Palisades Project Manager of the actions we plan to implement.*

.. ~

\\;:S. c;:, 4 -

\\'\\ David W. Rogers

~

Plant Safety and Licensing Director CC Administrator, Region III, USNRC NRC Resident Inspector - Palisades