Peak Rod TABLE 3.23-1 LINEAR HEAT.RATE LIMITS No. of Fuel 208 15.28 kW/ft TABLE 3.23-2 Rods Assembly 216

15. 28 kW/ft RADIAL PEAKING FACTOR LIMITS, FL Peaking Factor No. of Fuel Rods in Assembly 208 216 216 216

{Reload M Reload N Reload 0 and earlier)

Assembly F.A 1.48 1.57 1.66 I. 76 Peak Rod FrT 1.92 1.92 1.92 2.04 TABLE 3.23-3 POWER DISTRIBUTION MEASUREMENT UNCERTAINTY FACTORS LHR/Peaking Factor Measurement Measurement Measurement Parameter Uncerta i nty181 Uncerta i nty'bl Uncerta i nty'cl LHR 0.0623 0.0664 0.0795 FA r 0.0401 0.0490 0.0695 FT r 0.0455 0.0526 0.0722

{a)

Measurement uncertainty for reload cores* using all fresh incore detectors.

{b)

Measurement uncertainty for reload cores using a mixture of fresh and once-burned incore detectors.

{c)

Measurement uncertainty when quadrant power tilt, as determined using i ncore measurements and an i ncore analysis computer program161,

exceeds 2.8% but is less than or equal to 5%.

3-107 Amendment No. ~~' 11~, 1~~' 144 9210300165 921023 11 PDR ADOCK 05000255 p