Palisades Nuclear Plant:
27780 Blue Star Memorial Highway, Covert, Ml 49043 February 27, 1991 Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 DOCKET 50-255 - LICENSE DPR PALISADES PLANT -
1990 ANNUAL OPERATING REPORT - OCCUPATIONAL EXPOSURE GB Slade General Manager The annual report covering occupational exposure during 1990 as required by Palisades Technical Specification 6.9.1.b is attached.
~~-
Gerald B Slade General Manager CC Administrator, Region III, USNRC NRC Resident Inspector - Palisades Attachment 9103050332 901231 PDR ADOCK 05000255 R
- ~- -:... '-'........
A CM5 ENERGY COMPANY
/J{5lr 1
)
1 I
ATTACHMENT Consumers Power Company
- Palisades Plant Docket 50-255 1990 ANNUAL OPERATING REPORT OCCUPATIONAL EXPOSURE February 27, 1991 2 Pages
\\:
1990 Occupational Radiation Exposure The attached table summarizes personnel radiation exposure by job function, workgroup and employer for the year 1990.
The attached table and the method by which it was prepared meet the reporting requirements of Section 6.9.1.b of the Palisades Plant Technical Specifications.
The exposures, derived from Direct Reading Dosimeter (ORD), and Electronic Dosimeter (ED) data, were adjusted by a factor which corrects the ORD/ED exposure so that it is nearly equal to the thermoluminescent dosimeter exposure used in compiling the legal radiation exposure record for each individual. This correction factor is applied to each job function/workgroup/employer category on the attach~d table.
Special maintenance activities for the year 1990 include Steam Generator replacement; refueling equipment upgrade; extensive piping hanger repairs and valve work; ex-vessel dosimetry; Safety Injection and Refueling Water (SIRW) tank and fuel pool heat exchanger repair and Primary Coolant Pump (PCP) lube oil system modification.
PALlSADtS NUCLEAR PLANT REGlJt.ATORY GUIDE 1.16 APPENDIX A ANNUAL RF.PORT Number of Personnel (> 100 mrem) f otal Han-Rem
~---------~-------------------~----~--
Job Function Contract Contract Vork Group Station Utility
& Other Station Utility
& Other Routine Operations & Surv.
5 3
27 2.533 Kaintenance Personnel
- o. 735 8.784
~erations Personnel 45 0
1 15.148 0.057 2.820 ealth Physics Personnel 21 0
163 8.084 0.000 61.539 Supervisory Personnel 5
1 3
2.599 0.190 1.111 Engineerin~ Personnel 5
1 3
2.292 0.341 2.522 Routine Kain enance Kaintenance Personnel 70 0
159 52.285 0.854 81.591 Operations Personnel 0
0 4
0.423 0.000 1.307 Health Physics Personnel 5
0 27 1.516 0.000 9.760 Supervisory Personnel 2
0 2
0.968 0.009 3.373 Engineering Personnel 1
5 11
- o. 735
- 2. 738 7.972 Inservice Inspection 38 Kaintenance Personnel 0
0 0.256 0.000 21.987 Operations Personnel 0
0 1
o.ooo 0.000 0.341 Health Physics Personnel 0
0 3
0.091 0.000 0.678 Supervisory Personnel 0
0 1
0.020 0.003 0.182 Engineerin~ Personnel 0
5 19 0.117 5.192 7.254 Special Kain enance 8
Kaintenance Personnel 17 425 3.932 4.518 289.841 Operations Personnel 0
0 16 0.168 0.042 8.493 Health Physics Personnel 7
0 153
- 1. 732 0.000 45.861 Supervisory Personnel 1
0 9
0.384 0.037 2.844 Engineering Personnel 0
4 101 0.289 0.900 57.753 Vaste Processing Kaintenance Personnel 0
0 0
0.184 0.004 0.177 Operations Personnel 0
0 0
0.193 0.000 0.007 Health Physics Personnel 10 0
0 4.931 0.000 1.081 Supervisory Personnel 0
0 0
0.096 0.003 0.000 Engineering Personnel 0
0 0
0.010 0.000 0.145 Refueling Kaintenance Personnel 5
28 0
1.657
- 17. 788 0.147 Operations Personnel 5
0 0
1.870 0.000 0.093 Health Physics Personnel 0
0 4
0.043 0.000 1.584 Supervisory Personnel 0
0 0
0.301 0.040 0.018 Engineering Personnel 1
0 16 0.420 0.000 10.369 TOTAL Maintenance Personnel 88 48 649 60.847 23.899 402.527 Operations Personnel 50 0
22 17.802 0.099
- 13. 061 Health Physics Personnel 43 0
350 16.397 0.000 120.503 Supervisory Personnel 8
1 15 4.368 0.282 7.528 Engineering Personnel 7
15 150 3.863 9.171 86.015 GRAND TOTAL 196 64 1186 103.277 33.451 629.634