June 20, 1989
- Docket No. 50-255 Serial No. PAL-89-019 Mr. Kenneth W. Berry Director, Nuclear Licensing Consumers Power Company 1945 West Parnall Road Jackson, Michigan 49201
Dear Mr. Berry:
SUBJECT:
REACTOR COOLANT PUMP TRIP {TAC NO. 49700)
The staff has approved, in Generic Letter 86-06, the Combustion Engineering Owners Group (CEOG) methodology for the Reactor Coolant Pump Trip issue as defined in TMI Action Plan Item II.K.3.5. This approval was conditioned upon each licensee addressing plant-specific information.
Our review of the Palisades plant-specific information has progressed sufficiently for us to conclude that using the CEOG methodology has significantly improved reactor safety, and there are no remaining major safety-significant concerns for plant-specific information related to this issue.
Accordingly, we have completed our review of your Reactor Coolant Pump Trip set point development and find it acceptable.
Please be advised that the implementation of actions related to this issue may be subject to on-site verification.
cc: See next page DISTRIBUTION DOCKET FILE NRC & LOCAL PDRs PD31 GRAY FILE MVIRGILIO ADEAGAZIO OGC EJORDAN BGRIMES DJAFFE ACRS(lO)
Sincerely,
,i~ signed by Albert W. De Agazio, Project Manager Project Directorate III-1 Division of Reactor Projects - III, IV, V
& Special Projects Office of Nuclear Reactor Regulation LA/PD3l:DRSP PM/PD31:rlRSPr PSHUTTLEWO~~
ADEAGAZI~
6/;'~/89 6te!\\.. 1s9 I
~~::----=~~~---
~~yo~20348 890620
\\
(A)D/PD31,RSP LYANDELL 6/~q /89
~:DI-\\
ADOCK O!;:i(H)~~~;;~~S
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 Docket No. 50-255 Serial No. PAL-89-019 Mr. Kenneth W. Berry Director, Nuclear Licensing Consumers Power Company 1945 West Parnall Road Jackson, Michigan 49201
Dear Mr. Berry:
June 20, 1989
SUBJECT:
REACTOR COOLANT PUMP TRIP (TAC NO. 49700)
The staff has approved, in Generic Letter 86-06, the Combustion Engineering Owners Group (CEOG) methodology for the Reactor Coolant Pump Trip issue as defined in TMI Action Plan Item II.K.3.5. This approval was conditioned upon each licensee addressing plant-specific infonnation.
Our review of the Palisades plant-specific infonnation has progressed sufficiently for us to conclude that using the CEOG methodology has significantly improved reactor safety, and there are no remaining major safety-significant concerns for plant-specific infonnation related to this issue.
Accordingly, we have completed our review of your Reactor Coolant Pump Trip set point development and find it acceptable.
Please be advised that the implementation of actions related to this issue may be subject to on-site verification.
cc: See next page b~~foJQQ~
Albert W. De Agazio, Project Project Directorate III-1 Division of Reactor Projects -
V
& Special Projects Office of Nuclear Reactor Regulation
Mr. Kenneth W. Berry Consumers Power Company cc:
M. I. Mi 11 er, Es qui re Sidley & Austin 54th Floor One First National Plaza Chicago, Illinois 60603 Mr. Thomas A. McNish, Secretary Consumers Power Company 212 West Michigan Avenue Jackson, Michigan 49201 Judd L. Bacon, Esquire Consumers Pow~r Company 212 West Michigan Avenue Jackson, Michigan 49201 Regional Administrator, Region III U.S. Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, Illinois 60137 Jerry Sarno Township Supervisor Covert Township 36197 M-140 Highway Covert, Michigan 49043 Office of the Governor Room 1 - Capitol Building Lansing, Michigan 48913 Mr. Gerald Br Slade Pl ant Genera 1 Manager
- Palisades Plant 27780 Blue Star Memorial Hwy.
Covert, Michigan 49043 Resident Inspector c/o U.S. Nuclear Regulatory Commission Palisades Plant 27782 Blue Star Memorial Hwy.
Covert, Michigan 49043 Palisades Plant Nuclear Facilities and Environmental Monitoring Section Office Division of Radiological Health P.O. Box 30035 Lansing, Michigan 48909