June 26, 1984 Docket No.:

50-255 LS05-84-06-047 Mr. David J. VandeWalle Nuclear Licensing Administrator Consumers Power Company 1945 W. Parnall Road Jackson, Michigan 49201

Dear Mr. VandeWalle:

SUBJECT:

REQUEST FOR RELIEF FROM HYDROSTATIC TEST PRESSURE REQUIREMENTS Re:

Palisades Plant By letter dated May 14, 1984, you requested relief from the hydrostatic test pressure requirements of the 1977 Edition through Summer 1978 Addenda of Section XI of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code after modification and repair of the auxiliary feedwater and main feedwater lines at the Palisades Plant.

We have completed our review of your request and have determined that the hydrostatic pressure test requirements are impractical to perform. Accordingly, your request for relief is approved.

The NRC staff has determined that the granting of this relief is authorized by law and will not endanger life or property or the common defense and security and is otherwise in the public interest considering the burden that would result if they were imposed on your facility.

The NRC staff's Safety Evaluation is enclosed.

Enclosure:

Safety Evaluation cc: w/enclosure See next page DISTRIBUTION Docket File Local PDR NSIC LA OELD JG race SEPB DL: ORB #~

CJamerson (o l:;._Cu/84 NRC PDR ORB #5 Reading DCrutchfield WPaulson EJordan ACRS (10)

GJohnson Sincerely, Original signed by Richard L. Emch, Jr., for/

Dennis M. Crutchfield, Chief Operating Reactors Branch #5 Division of Licensing DLH~N #5 WPatll,so'n: dk

~ !Jf /84 DL: ORB Me k DCrutchfield

!/-. 6 12(/84 8406290199 840626

~DR ~DOCK 05000255 PDR

Mr. David J. VandeWalle cc M. I. Miller, Esquire Isham, Lincoln & Beale Suite 4200 One First National Plaza Chicago, Illinois 60670 Mr. Paul A. Perry, Secretary Consumers Power Company 212 West Michigan Avenue Jackson, Michigan 49201 Judd L. Bacon, Esquire Consumers Power Company 212 West Michigan Avenue Jackson, Michigan 49201 James G. Keppler, Regional Administrator Nuclear Regulatory Commission, Region III 799 Roosevelt Road Glen Ellyn, Illinois 60137 Township Supervisor Covert Township Route 1, Box 10 Van Buren.County, Michigan 49043 Office of the Governor Room 1 - Capitol Building Lansing, Michigan 48913 Palisades Plant ATTN:

Mr. Robert Montross Plant Manager Covert, Michigan 49043 U.S. Environmental Protection Agency Federal Activities Branch Region V Office ATTN:

Regional Radiation Representative 230 South Dearborn Street Chicago, Illinois 60604 Resident Inspector c/o U.S. NRC Palisades Plant Route 2, P. 0. Box 155 Covert, Michigan 49043 June 26, 1984 Lee E. Jager, P.E., Chief Environmental and Occupational Health Services Administration Michigan Department of Public Health 3500 N. Logan Street Post Office Box 30035 Lansing, Michigan 48909

  • '.~*~