ML18051A838

From kanterella
Jump to navigation Jump to search
Radiological Environ Monitoring Rept,1983
ML18051A838
Person / Time
Site: Palisades 
Issue date: 12/31/1983
From: Johnson B
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
NUDOCS 8404060377
Download: ML18051A838 (30)


Text

Consumers Power Company Palisades Plant - Docket 50-255 1983 RADIOLOGICAL ENVIRONMENTAL MONITORING REPORT Covering the Period from 8404060377 831231 PDR ADOCK 05000255 R

PDR OC0384-0014AA-NL02 January 1 through December 31, 1983 March 30, 1984 27 Pages

A.

INTRODUCTION B.

The data obtained by an analysis of samples taken. during 1983 was statis-tically analyzed at the 95% confidence level by the method described in Consumers Power Company internal procedures RSD-E-03.

The data was statically evaluated against two criteria.

The first is the statistical level which indicates the analysis of samples taken from near sites are higher than those taken from remote control sites but the difference is not significant.

The second is the report level (two.times the statis-tical level) which is the minimum detectable difference that exceeds zero

  • at a 95% confidence level.

Doses to the public will be evaluated if the report level is exceeded.

DISCUSSION AND INTERPRETATION OF RESULTS

1.

Air Samples Statistical analysis of the airborne particulate sample data between perimeter and control sites did not exceed reporting level.

In many instances, control sites sample values were higher than the perimeter site values.

No I-131 activity was reported above minimum detectable levels.

A total of 624 samples were collected and analyzed; however 6 sample results were deleted from statistical evaluation due to low and/or estimated sample volumes.

The missing sample resu.lts do not indicate any significant reduction in the overall sample program.

Technical Specification sensitivities were met and no reportable leyels exceeded.

The results are consistent with actual effluent releases and site-specific meteorology.

. 2.

Lake Water Statistical analysis between the plant lake water intake and the South Haven treated drinking water samples showed that statistical levels for gross beta or tritium were not exceeded.

The plant lake water outlet samples contained tritium above the statistical limit; nowever, this is consistent with monthly reported tritium effluent releases.

Lake water outlet samples for the months of.March and September were analyzed for gross beta when initial sample results were above the administrative notification limit of 10 pci/L {both were 11 pci/L).

The sample reanalysis data placed gross beta levels at 7 pci/L and 6 pci/L respectively.

Technical Specification sampling and sensitivity requi.rements were met.

IC0383-0013A-RS01

3.

Drinking Water See lake water and well water discussion.

4.

Well Water Statistical sample data analysis between the site well supply and two off-site locations showed that the statistical level was not exceeded.

The State Park off-site control location has been histor-ically higher in gross beta concentrations than either the township park off-site well or on-site well locations.

Technical specifica-tion sampling and sensitivity requirements were met, except for the May Palisades well sample.

The sample was inadvertently mislabeled and sent in for analysis.

The laboratory, because of the sample's conflicting identification, disposed of it. The missing.sample does not significantly affect the program.

5.

Milk

6.

No problems were encountered in obtaining milk samples for 1983.

Statistical analysis of sample data between site and control locat~ons showed that reporting levels for Sr-90 and Cs-137 were not exceeded.

I-131 was less than detectable for all samples.

The results of the milk sampling program provides reasonable assurance that plant.

effluent* releases.d~d not result in exposure to the public in excess of 5% of 10 CFR 20 limits.

Technical Specification sampling and sensitivity requirements were met.

Sediment Statistical analyses of sediment data was done using control samples from the Ludington Pump Storage Facility (located approximately 200 miles North of South Haven) and site samples.

Gross beta results did not exceed a statistica-1 significance level.* In many cases the control sample beta values were higher than the site values.

Sr-90 was reported in 9 of the 13 sites, to include all 5 control sites.*

No reportable Sr-90 levels were reached.

This is consistent with published environmental data showing residual amounts of Sr-90 in Lake Michig~n from-weapons testing.

Levels of Sr-90 from 1983 and 1982 samples are within 10% of each other. _No detectable levels of Cs-137 were found at any sample location.

Technical Specification sampling and analysis requirements were met.

IC0383-0013A-RS01

7.

Organic - Fish and Crops The reportable limits for organic sample results are based on Technical Specification 4.11.2.

S_r-90 results ranged from <,005 pci/gm to.024 pci/gm with no detectable levels of Cs-137 found.

These analytical results are approximately 15% less than those results reported in 1982.

Technical Specification sampling and analysis requirements were met.

8; Gamma Dose -

TLD There were no missing TLD's during 1983.

Statistical analysis of TLD data was done by comparing all indicator locations to control locations.

No monthly, quarterly or annual analyses exceeded the statistical level.

The Palisades gamma dose sampling program consists of 21 TLD stations:

10 directly on-site; 8 off-site (1-7.5 mi); and 3 control locations.

In separate comparison of off-site TLD data and on-site TLD data to the control TLD locations, the on-site locations had an average of 9.8 mr/month to an average of 10.4 mr/month for control TLD's.

The off-site TLD's average 10.5 mr/month.

This is consistent with expected results based on reported effluent releases.

Statistical analysis of the annual TLD stations indicate a statistical level of 5.4 mR/yr would have been detected if present.

Technical specification analysis sensitivities were met.

C.

SUMMARY

Only one required Technical Specification analysis was missed in 1983.

That sample is discussed in B.4.

Six of the six hundred twenty four air samples collected in 1983 were deleted from the statistical analysis because of estimated flows due to meter malfunctions.

Three of the malfunctions occurred in the last two weeks of December due to the extremely cold weather.

All Tech Specification analysis requirements were met except for sample noted above.

Technical Specification requirements for calibration of air samplers meters was met.

The missing or deleted results did not constitute a significant reduction in the overall program and no special reports per T.S. 6.9.3.2 were made on 1983 requirements.

D.

1983 data analysis was done by Eberline Laboratories.

In 1984, the analysis will be performed by Teledyne Isotopes Laboratory, Northbrook, Illinois.

IC0383-0013A-RS01

E.

ATTACHMENTS Tables RSD-E-03A, B, C, Das required by Technical Specification 6.9.3.1.B.

Sample location maps Trend graphs of analytical results IC0383-0013A-RS01

Medium or Pnthway Sampled

.Unit of Meas1irement Air (pCi/m3 )

, Lake Water (pCi/l)

Drinking Water (pCi/l)

Well Water (pCi/l)

Analysis and Total Number of Analyses Performed Gross Beta 624 I-131 624 Gross* Alpha 24 Gross Beta 24 Tritium 24 Gross Beta 12 Tritium 12 Gross Beta 35 IC0383-0013A-RS01 TABLE RSD-E-OJA Environmental RadiologlcaJ Monitoring Program Summary Palisades Nuclear Plant, Docket DPR-20 Van Buren County, Michigan, January 1, 1983 to December 31, 1983 Lower Limit of Detection( a)

LLD 0.01 0.02 1.0.

1.0 100.0

. 1.0 All Indicator Locations Meari(b)

Range(b)

(464/468)

.03 (.01-.09) all LLD (0/12)

<1 (<1)

(12/12) 4.7 (1-11)

(12/12) 604.2 ( 100-2200)

Locatlon with Highest Annual Mean Name Distance & Direction KZ 35 mi SE N/A Discharge Discharge Discharge Mean(b)

Range(b)

.032

(.01-.07)

<1 (<1) 4.7 (1-11) 604.2

( 100-2200)

All Control Locations Hean(b)

Range(b)

(154/156)

.03 (.Ol-.07)

LLD (0/12) <1 (12/12) 3.6 ( 1-8)

(12/12) 168,3 ( 100-380)

Control lake and well water samples are drinking water supplies.

100.0.

1.0 (11/11) 2.2 ( 1-6)

State Park (1 mi N) 6.1 (3'-9)

(24/24)

  • 4.4 ( 1-9) page 1 of 4 Nonroutine Reported Measurements((:)

None None J

None None None None

Analysis and

' Medium or Total* Number of

Pathwal Sam~led Anallses Performed Unit of Measurement Ml.lk I-1.31 48' (pCi/l)

Sr-89 48 Sr-90 48 Cs-137 48 Other Gamma Gamma Exposure TLD (Monthly) 252 (mil/Month)

(mR/Quarter)

TLD (Quarterly) 84 TLD (Annually) 21 Crops Gross Beta 20 (pCi/g Wet)

Sr-89 20 IC0383*0013A-RS01 TARLE RSD-E-03A Environmental Radi.ological Monitoring Program Su~

Palis~des Nuclear Plant, Docket DPR-20 Van Buren County, Michigan, January 1, 1983 to December. 31, 1983 Lower Limi.t All of Indicator Location with Highest Detection( a)

Locations Annual Mean LLD Mean(b)

Name Mean(b)

Range(b)

Distance & Direction Range(b)

.5 (0/36)

All LLD NA 5.0 (0/36)

All LLD NA 1.0 (36/36)

GM (5 mi SE) 5.7 4.7 ( 1-12)

(2-12) 1.0 (36/36)

GM (5 mi-SE) 4.9 4.9 ( 3-9)

( 3-9)

KK (5 mi N) 4.9

( 3-7) l.O (0/36)

NA NA l.O (216/216)

ST-04 (3.5 mi ESE) 10.9 10.4 (4.7-14.5)

(9-13.6)

(72/72)

ST-06 (4.75 mi NE) 19.5 16.9 (13.5-22.6)

(18.1-22.6)

(18/18)

ST-05 (3 mi E) 57.1 46.6 (42.1-57.1) 1.0 (20/20)

RB (4.75 mi NE) 32 9.8 (1.3-28)

Cabbage N/A 0.025 (0/20)

NA MLD All Control Locations Mean(b)

Range(b) 0/12 LLD 0/12 LLD (12/12) 4.6 (1-11)

(12/12) 4.8 ( 4-5)

(0/12) LLD (36/36) 10.4 (6.6-14.4)

  • (12/12) 17.l (15-19.9)

(3/3)

'*9. 9 (45.0-54.8)

None None

  • ~

Page 2 of 4 Nonroutine Reported Measurements None None None None None None None None None None j

Page 3 of *4 TABLE RSD-E-03A Environmental Radiological Monitoring Program Summar:z:

Palisades Nuclear Plant, Docket DPR-20 Van Buren County, Michigim, January l, 1983 to December 31, 1983

/

Analysis and Lower Limit All All Nonroutine Medium or Total Number of of Indicator Location with Highest Control Reported Pathway Sampled Analyses Performed Detection( a}

I.ocations Annual Mean Locations Measurements

' Unit of Measurement LLD Mean.(b)

Name Mean(b)

Mean(b)

Range(b)

Distance & Direction Range(b)

Range(b)

Crops Sr-90 20 0.005 (16/20)

RB (4.75 mi NE)

.028 None None

.012 (.005-.032)

Cabbage (NA)

Cs-137 20 0.08 (0/20)

NA None None MDL I-131 20 o.oa.

(0/20)

NA None None MDL Other Gamma*

20 0.1 (0/20)

NA None None MDL Sedi.ment Gross Beta 13 1.0 (8/8)

North Boundary and 13.3 (5/5)

None

.t (pCi/g Dry) 7.7 (4.6-13.3)

Ludington S Pier (NA) 9.7 (6.8-13.3)

Sr-89 13

. 0.025 (0/8)

NA (0/5)

None All LLD LLD

  • ~

Sr-90 13 0.005 (4 /8)

North Boundary

.124 (5/5)

None 0.45 (.005-.124)

(NA)

.057 (.036-.087)

Cs-137 I *13 0.08 (O/f})

NA (0/5).

  • None All LLD LLD Other Gamma 13 0.1 (0/8)

NA (0/5)

None All LLD LLD IC0383-0013A-RS01

Analysis and Medium or Total Number of Pathway Sam~led Analyses Performed Unit of Measurement Aquntf.c

. Grqss Beta 10 (pCi/g Wet)

Sr-89 1.0 Sr-90 10 Gamma 1.0.

Cs-137 10 TABLE RSD-E-03A Environmental Radiolog.ical Monitoring Program Summary Paliiades Nuclear Plant, Docket DPR-20 Van Buren County, Michigan, January 1, 1983 to December 31, 1983 Lower Limit All of Ind lea tor Location with Highest Detection(a)

Locations Annual Mean LLD Mean(b)

Name Mean(b)

Range(b)

Distance & Direction Range(b) 1.0 (10/10)

Vicinity of discharge 9.1 9.1 (3.4-16.7)

(3.4-16. 7) 0.025 (0/10)

NA All LLD 0.005 (5/10)

Vicinity of discharge

.015

.015 (.005-.043)

(.005-.043) 0.1 (0/10)

NA All LLD 0.08 (0/10)

NA All LLD

a.

Nominal Lower Limit of Detection (LLD).as defined in HASL-300 (Rev 8/73), pages D-08-01., 02, and 03.

None None None None None

b.

Mean and range bas.ed upon detectable measurements only.

Fraction of detectable measurements at specified locations is indicated in parentheses.

c.

Nonroutine reported measurements are defined in the Palisades Technical Specifications, Section 6.9.3.2.

IC0383-001.3A-RS01 All Control Locations Mean(b)

Range(b)

  • ~

Page 4 of 4 Nonroutine Reported Measurements None None None None None

~

~:.

.. ~... "... ' *... ;

Medium Description Air Continuous at Approx 1 CFM Lake 1 Gallon Water Composite Drinking 1 Gallon Water-Lake Composite Well 1 Gallon Water Grab Milk 1 Gallon Grab Gamma Continuous Dose Crops Grab Sediment Grab Aquatic Grab

  • 6 results deleted because IC0383*0013A-RS01 TABLE RSD-E-OJC PALISADF.S NUCLEAR PLANT JANUARY 1, 1983 TO DECEMBER 31, 1983 SAMPLING AND ANALYSIS

SUMMARY

Number of Samples Location Collected All; as identified on 624*

Table RSD-E-03B Intake, Discharge 24 South Haven 12 Site, TP,. SP 35

  • SDF, GM, KK, GH 48 All; as identified on

.252 Table RSD-E-03B 84 21 JS, PR, RB, HS, TH 20 Discharge, N & S Site 13 Boundary, 5 miles North Ludington (control)

Intake, Discharge 10 of me~er or sampler malfunctions.

Type of Analysis Gross Beta, I-131 Gross Beta, Gross Alpha, Tritium Gross Beta, Tritium Gross Beta I-131, Sr-89 and Sr-90, Cs-137 Isotopic TLD Dose Gross Beta, Isotopic, Sr-89 and Sr-90, Cs-137, Gross Beta, Isotopi~

Sr-89 and Sr-90, Cs-137 Gross Beta, Sr-89, Sr-90,.

Gamma Frequency of Analysis Weekly/12 Monthly/2 Monthly/I

  • Monthly/3 Monthly/4 Monthly/21 Quarterly/21 Annually/21 Whe~

Availabie-When Available When Available.

    • t, j

Medium Air TABLE RSD-E-03D llIGll, LOW AND AVERAGE CONCENTRATIONS FOR lllGllEST AVERAGE SAMPLING LOCATION PALISADES NUCLEAR PLANT JANUARY 1, 1983 to December 31, 1983 Type of Analysis(l)

Location High Gross Beta KZ Kalamazoo 35 mi SE

.01 pCi/m 3 Page 1 of 3 :

Low Average(5)

.07 pCi/m 3

.032 pCi/m3 I-131 All LLD

<.02 pCi/m3 Lake Water Gross Beta Discharge Gross Alpha Discharge Tritium Discharge Drinking Water Gross Beta See Table RSD-E-03A Tritium(4)

  • See Table RSD-E-03A Well Water Gross Beta State Park (1 mi N) 11 pCi/l 1 pCi/1

<1 pCi/1

<1 pCi/1 2200 pCi/l 100 pCi/1 9 pCi/l 3 pCi/1 4.7 pCi/l

<1 pCi/1 604.2 pCi/l 6.1 pCi/1 (l)Minimum detectable level (MpL) = air, gross beta 0.01 pCi/m 3, I-:131 0,02 pCi/m3 ; water, gross beta 1.0 pCi/1, gross alpha 1.0 pCi/l, H-3 100 pCi/l; milk, I-131 0.5 pCi/l, Sr-89 5.0 pCi/l, gamma isotopic 1.0 pCi/l; crops and sediment, gross beta 1,0 pCi/g, Sr-89 0,025 pCi/g, Sr-90 0.005 pCi/g, gamma isotopic 0.05 pCi/g; some samples may have higher MDLs due to sample size, shipRing delays or statistical phenomenon.

(2)Samples. collected monthly in season.

(3)Two"samples per location.

(4)Tritium analysis performed on South Haven treated only.

(S)Only samples greater than LLD included in average.

(6)Includes transit dose which averages approximately 6.4 mRlround trip.

IC038J-0013A-R$01

Medium Milk Gamma Dose(6)-

Crops(2)

IC0383-0013A-RS01 TABLE RSD-E-03D HIGH, LOW AND AVERAGE CONCENTRATlONS FOR HIGHEST AVERAGE SAMPLING LOCATION PALISADES NUCLEAR PLANT Type of Analysis(l)

I-131 Sr-89 Sr-90 Cs-137 Other Gamma TLD (Monthly)

TLD (Quarterly)

TLD (Annual)

Gross Beta Sr-89 Sr-90 Other Gamma JANUARY 1, 1983 to December 31, 1983 Location All LLD All LLD GM (5 mi SE)

GM (5 mi SE)

KK (5 mi N)

All LLD ST-04 (3.5 mi ESE)

ST-06 (4.75 mi NE)

ST-05 (3 mi E)

RB (4.75 mi NE)

All LLD RB- (4,75-mi N~)

All LLD All LLD High 12 pCi/l 9 pCi/1 7 pCi/l 13.6 mr 22.6 mr 32 pCi/g

.028 pCi/g Low 2 pCi/l 3 pCi/l 3 pCi/1 9 mr 18.1 mr 6 pCi/g

.006 pCi/g P11ge 2 of 3 Average 5.7 pCi/l 4.9 pCi/1 4.9 pCi/l 10.9 mr 19.5 mr 57.1 15.3 pCi/g

.015 pCi~g j

Medium Sed:l.ment(3)

Aquatic IC0383*0013A-RS01 TABLE RSD-E-03D llIGll, I.OW AND AVERAGE CONCENTRATIONS FOR llIGHEST AVERAGE SAMPLING LOCATION PALISADES NUCLEAR PLANT Type of Analysis(!)

Gross Beta Sr-89 Sr-90 Cs-137 Other.Gamma Gross Beta Sr-90 Gamma JANUARY l, 1983 to December 31, 1983 Location North Boundary and Ludington S Pier North Boundary

~ m:I. north All LLD All LLD Discharge All LLD Discharge All LLD High 13.3 pCi/g

.124 pCi/g 16.7 pCi/g

.043 pCi/g Low 4.6 pCi/g

<.005 3.4 pCi/g

.005 pCi/gm Page 3 of 3 Average 9.5 \\>Ci/g

.058 9.1 pCi/g

.015 pCi/g

  • ~

TABLE RSD-E-03B SAMPLING LOCATIONS PALISADES NUCLEAR PLANT Ill I

Q)

<ti

<1l Q) c........

c

l

,... u

,... "O Station Code Location

............ 0

<.µ <H 1

ST Palisades Nuclear Plant x

x 2

TH Tower Hill Farms x

x RR3, Coloma, Michigan 5 miles S 3

HS Herbert Soderberg x

x RRl, Covert, Michigan 5 miles S

  • 4 JS Jerry Sarno x

x RRl, Cov~rt, Michigan 3~ miles SE 5

PR Paul Rude x

x RRl, Covert, Michigan 3~ miles ESE 6

RB Richard Bus x

x RR3, South Haven, MI 4-1/4 miles NE 7

SD Sherman Dairy x

x South Haven, Michigan 6 miles NNE

    • 7.a SN35 Emergency Siren 35 4-3/ 4. miles NNE 8

SP State Park x

x 1 mile N

  • TLD P-22 is a control in lead cave at station 4.
  • Station 7.a was added to the program in January 1984.

page 1 of 3 Sample Q)

Q)

<t!

<1l c::

Q)

Ill E

Q)

~

Q..

..c

~

a "O

~

Q) co Q)

Q)

...J

,..J

~

u Cl)

E-1

~-

x x

x x

x x

x x

x x

x x

x x

x x

x

page 2 of 3 TABLE RSD-E-03B SAMPLING LOCATIONS PALISADES NUCLEAR PLANT Sample M

M I

Q)

Q)

I

(

.jj M.o co co c:

co l

Q)

~

~

Q)

~

c:

ID E

Q)

~

Q.

.c

... "C

~

0 "Cl t::::i ID Station Code Location

.......... 0 ell Q).....

Q)

,..J

<.. <lo-I

,..J

~

u Cf.)

E-i 9

TP Covert Township Park x x x

x l~ miles SSW 10 GR Grand Rapids, Michigan x x x

55 miles NNE 11 KZ Kalamazoo, Michigan x x x

35 miles SSE 12 DG Dowagiac, Michigan x x x

30 miles SSE 13-21 Pl3-P21 Perimeter of Palisades x

  • 23 SN25 Emergency Siren 25 x

3 miles ENE

  • 24 SN21 Emergency Siren 21 x

3-1/3 miles E 25 SH South Haven, Michigan x

x 5-1/2 miles NNE 26 GM Glenn Miller x

Rt 1, Box 20 Covert, MI 4.3 miles SE 27 KK Kenneth Kemp x

Rt 4, Box 32 South Haven, MI 8 miles NE

  • Stations 23 and 24 were added to the program in

~-

  • --, oo,.

~

TABLE RSD-E-03B SA}lPLING LOCATIONS PALISADES NUCLEAR PLANT Ol I

4J I-<.µ t1' t1' 4J i:i.........

c:

I o,.j I-< u I-< "C Station Code Location o,.j o,.j o,.j 0

<.µ <~

28 GH Glen Hessey Rt 2, Box 94 Bangor, MI 6 miles E 29

  • SD Control Sample 30 STN

~ mile N of discharge 31 STS

~ mile s. of discharge LP.

Ludington* *Pump Storage 116 miles N

  • Control sample is obtained 6 months of the year from Hudsonv"ille Creamery, Burnip, Michigan (35 miles NE), and the other 6 months from the Constantine Dairy, Constantine, Michigan (48 miles SE).

p::i.ge 3 of 3 Sample 1-4 I-<

4J QJ

.µ al al i::

~

~

4J

0) e 4J

~

0.

o,.j

.c:

~

~

0 "C

Q

0).

ti!

QJ

~ "'

4J

,..J

~

,..J

~

u Cl)

E-<

tz..

x x

x x

x x

I

  • -r 10 Ml 9 Ml 8 Ml 7 Ml Ill

,~.

,; u;

!!z,:;

'ti.,

-~-**t

~

s; I L_

f~-J--

~'!

~*

= L.ACDTA

~

~ !R

)

L._..

- p.

0 0

0 Q

I.

  • ........... r:I;)

.*1

\\

1~ -

/

I / / /, /

r/

I j,.....,.....

I//

\\

\\

~

I 8

/!

I I I

\\

\\

"l I

/

I

!!_.::! I I

\\

I

\\

\\"'

I

/

L

\\,

~'\\

//

/

////

/'~~:.* \\\\

', o

\\

I

/,.....

\\\\

\\

I 14 NNW NNE /

/

/rn::::;

1

~ \\

\\:

I

/

NW

\\

I

........... I NE

\\ : I 7~1--

,,;:it"'

\\

/~11111:::

./

I 1-....... /

... ~

WNW "t*~*.:;....

7"""",.,

ENE

'/

r~.,.. I 'I ;:.. -:-.-,*'--: '*-*

..;~~-

/.. __;

.\\..,

~-

~-~,,* -......... :.. {

_4' IJ/

*~*,,........,.-....- __.

~

-r::::-., ~ ---

E

_...:.\\~" - -.. --

w

  • ,i

/

r~"~' *t.'"'1.--,,

.,"... ?\\"'~

""";o. auovtw or INTA*r t.

..~,J.

1 1

~***~,.*~~:\\~~:.:;;~~,'"."....:::~1::;~~,~-'~":,::::::\\\\i*~~ ~-.~~::~::

' ',\\

AND OUTU 1 lAIU*[N fS

/

r _;

~t ::

IU t-19101 IMf 4 ll ~**,

WSW

\\\\::::.if}:;:. /-:;,::~**

ESE I

~

.... " \\. ""'"*......

~-........

- t ff':

I ii.*::;,"*

I

~:

~-.,._.....

I 1 1 I,'

\\ '\\

SE

__ ::~:**~~*::::*:::** :::*~**~;/:::::::

\\

Ir-- -

\\

\\

  • 7/

I I

SSW.,. 1

. \\

\\

,~:

  • -,,;:~~...
  • J.~....

i I s

\\

SSE

\\

~i;I

\\

\\\\

A17

/

\\

/

\\

/

(I~

I

/1

/

i I I I I

/,. --

..J- ~

I I

I

/

Jf.

  • ~

I

1.

Ii

    • .~ *1.v~:

1

.:1:1 1
  • \\'i*.:;

1

.1:11.*.-.*.r-11:1.

ir.11*.. 11; u II 1,., n ~~ *

.,u~~"'.;;: *

  • 21 I

\\

\\

I

/'

I A19\\

10..,

//'

.....,///

SITE ENVIRONMENT TLD STATION~

IUldf I* tlllf#I t*1U IU H*, **** 1CM1t*I

  • + I A20

//

/'I j

~}.i,.,,..,,

. ;* /,11

...... l*11t DI!!** t*lUlll*I

  • i. f

."hP 100* "° ($1.,,Z,4_

\\Hiit I IOUMtl*Y IUIVIT CONSUMERS POWER CO.

11111t,.***n,.1***.,t*O'""'***"'*PIUllllOMJ0t 1.1.c.. 1.nN. M1cma&111

PCI 0.12.5

0. 1 00 0.075 0.050 0.02.5 o.ooo

~ ~... *...

~ '

1983.PALJ.S:4DES AIR P~4RTICULA.TE DOff'A(:.JAC-C0.1\\7TROL VS SHERMAN DAIRY, R.BUS, P.RUDE WEEKLY GROSS BETA PC!/ Cf.I.BIG METER JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC

+

WEEK LEGEND:

LOCATION

~ *

~ DOWAO-C 39 SSE a

a s R.BUS 4.75 NE

....._.__... P.RUDE 3 E 4

4

& S DAIRY 7.5 NNE 03/28/B j

~*

  • ~ '...... '

~'.

PC I

0. 1 2 ~

11.100 0.075 0.050 0.02.5 1983 PALJS:4DE1-S 1 AIR P~4RTI 1CULATE KAL.AAlAZOO~CONTROL VS TOWNSHIP PARK, STATE PARK WEEKLY GROSS BETA PCI/CUBIC METER f

\\

JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC

+

WEEK LEGEND:

LOCATION

  • *
  • KAZOO-C 35 E

~

ST PARK 1 N B

B B

TWP PARK 1 I 5 s

,(~***~*.\\

03/28/B

  • ~

j

p(; I 0' 1 25

0. 1 00 0.075 0.050 0.02.5

\\,.

  • . *.: "... *~ *.

198~3.PALJS:4DE.S AIR P~4RTICULA.TE

(:RAND RAPIDS-CONTROL vs TOWER HILL. HTSEDERBERG ** l.SARNO WEEKLY GROSS BETA PCI/CUBIC METER JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC

+

WEEK LEGEND:

LOCATION

  • *.
  • G.R.-C 55 NNE t

H.SODERBERG 5 SE 4

4 4

TOWER HILL 5 SSE e e e J.SARNO J,5 ESE 03/28/8

j.t 1---.. --

MR 20 15 JAM MAR APR LEGEHD:

LOCATION P12 C01VTROL V15' P05 P06 pen MILLI REM MAY JUN JUL AUO DATE

-<J.--.ji*--+-

p 0 5-

3.

E

~ a a P07 7.5 NNE 03/16/8 s E: p O C T HOV DEC

-v-;,-;,-

P 0 6 4, 7 5

  • f*J E

-d--A-11:- P12C 30 SSE

\\

MP:.

"- \\.J 1 fi JAN FEB LEGEND:

LOCATION J.-*-*,

MAR.

1 ci o ~1 }J A r I r.:-;-1 /I D r;1 (.::i lfl'l ['t CJ U

~.. )

_,_.Lf Lj 1._}.li.

L'J 1._)

...1t P11 C01VTROL VB P08 POE1 APR MAY

-<11--+-+-

P 0 8 1

N MILLI REM J LHJ DATE JUL A U G SEP

---~ PCdJ 1.5 S

(,...,,

\\

,,..---.~

\\

03/115/5

  • C 0 CT HOV e

e a*p11c :35 E

. \\

MR i:;

I

  • t

~...

  • 1Cl0 (). 1-)A/ L~.. J,;,..Li TJE-~.~i 71'L*l*J-CJ '-..)'.__)

~

f.__,, ~ lL*

    • ~

MAR APR LEr)END:

LOCATION P10 C01VTROL VB POZ F'0:3 MILLIREN MAY JUN JUL A. U G DATE

+

+ P02 5

SSE B

B B P10C 55 NNE

3 E p

\\; ; '.....

03/.15/8.*

OCT NOV DEC P03 5

SE*

i

\\

1 SJ8.:3. F)i-ll.1I.

.S:'~4D.l~.. S'* 11111~,JC *...S~41l.fFJ L.. E.. S!

F* C.1 4 (;<

2. 0 1 5 1 0

,JAN*

FEB MAR LEGEND:

LOCATIOM SHERMAN--CO.lVTROL rrs HEB;5*EY JfILLER KEMP CS-137 PCI,/L APR MAY JUH JUL A. UG SEP DATE OCT r;

+ "'

HESSEY

+-+-+ K E t,1 P NOV e

a a MILLER

& & & SHERMAN-CONTROL

~.. \\

fl 7 /1 fi' /5.

w..J/

'Jj

,i DEC

r--

1 I -

I I

I PCI

2. 0 1 5 1 (j 5

198~3 i r;'

1,,,

l -) *1 L T r-*1

  • 1 L' -, -*1

---1

.1

.. l-i

{.1,* __ )...:.."""i

,I _L_,i / __ }

r.1rr;1 r L 1* ' L.J L.i T'V~4 TE It.

'1'1 A ~1

.... PL r;r C1 f.. _,.. li

....l k

.-b* f~)

TOWJ\\ISHIP PARK & STATE' PARK-CONTROL VB SITE GRO.SS BETA.. PCI,/L

'-r-~~-~~~--~~~~~~~~~~-*~~~~~~~--r-JAN FEB M

.A. R APR M.A. y JUN JUL

.A. U G SEP OCT MO\\/

DATE LEGEMD:

LOCATION

---..(*** PAL SI TE

-Et--£1--f!-

T W P P A P. ~~ - C 0 H T DEC

,*.-,~,*"'.:""~

(. ;,,

r-.. ------------------

PC I.

I 1 o' J'=.

4 2

0 J A M 198~3 F)_,.4L.JfS~4_DE;.s/ 1,L4J(E H'~4. TE.11:

~S:411I1~)L.E.. s 1

FEB 80U7'H 1-lAVEN. TREATED e,., RAW-CONTROL Vi5 I1V1:4KE BET..4. PC.T/L M.A.R *. APR MAY JUN JUL A.UG SEP DATE

. r OCT NOV LEGEND:

LOCATION

"'ill ljl IMTA~~E El

& & S.H.RAW C e

9 e S.H.TREATED C

, ~~..........

1';'*"'"';:-i 03/16/B

-i-D EC j

1-I ! -

. I,

I.,..

I I

F' (: I 1983 F~4[,J,S~41JE.5/ ]~,_ilf(E Pv:4TEH *.,s:4J.fl-)LiE..S 1

,JAM FEB MAP.

SOUTH HA TlEN TREA.TE.D--CO.NTROL VB INTftKE

'Tl:?.IT'lUM PCI_/L MAY

,JU II JUL AUG SEP DATE 0 CT 1"10 V 1',*****.. \\

03/16,/B

LEGEND:

LOCATION

+

+

+

INTAKE

~

8

& S.H.TREATED C

I*

PCI 1 f.

JAM FEB i' ~~\\

1 t)8:3. _f?ilL.I.. ~~:-:;1£) F 1

.. St. J]f JLJ(... ~vll1f P L.. E.. s:

8HJ:.""'R.MA1V-C01VTROL ViSt HESSEY MIL*LER KEJ_VP SR-9D FCI./L' MAR,.

.A.PR M.A. y JUN JUL SEP DATE OCT HOV LEGEND:

LOC.A.T I ON

+

i1>-

HESSEY

-1t-

~

~( EM P a all-t~llLLER

& SHERMAN-CONTROL

":.\\

03/16/84 j

DEC

General Offices: 1945 West Parnall Road, Jackson, Ml 49201 * (517) 788-0550 March 30, 1984 James G Keppler, Administrator Region III US Nuclear Regulatory Connnission 799 Roosevelt Road Glen Ellyn, IL 60137 DOCKET 50-255 - LICENSE DPR PALISADES PLANT - 1983 RADIOLOGICAL ENVIRONMENTAL MONITORING.REPORT Attached is the 1983 Environmental Monitoring Report for the Palisades Plant.

This covers the period January 1 through December 31, 1983 and is submitted in accordance with Technical Specification 6.9.3.1.B.

Brian D Johnson Staff Licensing Engineer CC Director, Office of Nuclear Reactor Regulation Director, Office of Inspection and Enforcement NRC Resident Inspector - Palisades Attachment OC0384-0014AA-NL02 If:.* ~5

  • \\ 1 APR 3 1984