ATTACHMENT Consumers Power Company Palisades Plant - Docket 50-255 RADIOACTIVE EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT JULY THROUGH DECEMBER 1983 9403080206 831231 PDR ADOCK 05000255 R

PDR OC0284-0015B-NL02 February 1984 9 Pages

PALISADES NUCLEAR PLANT SEHIANNUAL EFFLUENT REPORT JULY - DECEMBER 1983 This* report provides information relating to radioactive effluent releases and solid radioactive waste disposal operations of the Palisades Plant during the period of July through December 1983 in the format contained in Plant Technical Specification 6.9.3.1.A.

1.

Supplemental Information

a.

Batch Releases Information relating to batch releases of liquid and gaseous effluents is provided in Table 1.

b.

Abnormal Releases - none.

2.

Gaseous Effluents Table 2a presents a* summary of all gaseous radi.oactive effluents released during the period.

Release totals for each radionuclide determined to be present in gaseous effluents are contained in Table 2b.

The unidentified portion was 4.00E-6% of the total release.

3.

Liquid Effluents Table 3a presents a summary of all liquid radioactive effluents released.

during the period.

Release totals for each radionuclide determined to be present in liquid effluents are.contained in Table 3b.

The unidentified portion was 6.05E-4r. of the total release.

Laundry releases for 1983 were 41.6% of Technical Specification limits.

4.

Solid Waste Quantities of solid waste shipped off site and the disposition of these shipments are presented in Table 4.

5.

Radiological Impact on Man Potential doses to individuals and populations were calculated using GASPAR and LADTAP computer codes.

The annual values for curies released were input for each nuclide.

a.

Doses to individuals in unrestricted areas received from water related exposure pathways are 4.74E-2 mrem maximum total body dose (adult) and 7.51E-2 mrem maximum orgnn dose (teenage liver dose).

b.

The maximum offsite air doses are l.50E-l mrads for beta and 5.0SE-2 mrads for gamma;

c.

The most restrictive organ dose is the thyroid dose.

The average thyroid dose to individuals within a distance of 50 miles of the site from radioactive iodine and radioactive material in particulate form from major pathways of exposure is l.23E-3 mrem.

d.

Total body doses to the population and average doses to individuals in the population from receiving water related pathways to a distance of

.50 miles from the site are l.58E-l manrem and l.50E-4 mrem respectively.

e. Total body doses to the population and average doses to individuals in the population from gaseous effluents to a distance of 50 miles from the site are 7.37E-2 manrem and 7.02E-5 mrem respectively~

A.

GASEOUS Number of Releases Total Release Time Maximum Release Time Average Release Time

~

Minimum Release Time B.

LIQUID Number of Releases Total Release Time Maximum Release Time Average Release Time Minimum Release Time MI0284-0026A-RSOJ TABLE l PALISADES PLANT BATCH RELEASES JULY 1983 through DECEMBER 1983 Units Third Quarter 9

Minutes 2.39E3 Minutes 6.30E2 Minutes 2.65E2 Minutes l.50E2 49 Minutes 8.86E3 Minutes 9.76E2 Minutes

l. 81E2 Minutes 37 Fourth Quarter l

5.66E2 5.66E?.

5.66E2 5.66E2 50 f

6.87E3 5.50E2 l.37E2 40

A.

B.

c.

D.

t..

TABLE 2a PALISADES PLANT EFFLUENT AND WASTE DISPOSAL SEMIANNUAL.REPORT GASEOUS EFFLUENTS -

SUNMATION OF ALL RELEASES JULY 1983 through DECEMBER 1983.

THIRD FISSION & ACTIVATION GASES UNITS QUARTER I. Total release Ci 8.14E2

2.

Average release rate for period

µCi/sec l.02E2

3.

Percent.of Technical Specification Limit 6.82E-2 IODINES

1.

Total Iodine-131 Ci l.80E-2

2.

Average release rate for period (I-131)

µCi/sec 2.26E-3

3.

Percent of Technical Specification Limit (I-131)

1. 58E-1 PARTICULATES
1. Particulates with half-life >8 days Ci 1.SOE-4
2.

Average release rate for period

µCi/sec 1.88E-5

3.

Percent of Technical Specification Limit

1. 34E-4
4.

Gross alpha radioactivity Ci l.68E-6 TRITIUM

1.

Total release Ci

1. 78
2.

Average release rate for period

µCi/sec 2.24E-l

3.

Percent of Technical Specification Limit 2.24E-4 PERCENT OF GASEOUS EFFLUENTS OF APPENDIX I VALUES

1. 12 MI0294-0026TI-RS01 FOURTH EST TOTAL QUARTER ERROR %

l.32E-2 4.01 I. 66E-3

1. llE-6 8.15E-4 5.20 I l.03E-4 7.20E-3 l.OSE-3 29.2 I

l.32E-4 1.07E-4

l. 19E-6 2.38 2.99E-l 2.99E-4 5.89E-2
1.

FISSION GASES Krypton-85 Krypton-85m Krypton-87 Krypton-88 Xenon-13lm Xenon-133 Xenon-133m Xenon-135 Xenon-135m Argon-41 Total for period

. 1.

IODINES Iodine-131 Iodine-132 Iodine-133 Iodine-135 Total for period MI0284-0026C-RS01 TABLE 2b PALISADES PLANT EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT GASEOUS EFFLUENTS -

GROUND LEVEL RELEASES JULY 1983 through DECEMBER 1983 Units Third Quarter Ci 2.15 Ci l.06E-2 Ci l.29E-3 Ci 1.57E-2 Ci 1.33 Ci 8.10E2 Ci

-4. 31E-2 Ci 9.24E-2 Ci 8.34E-2 Ci 3.86E-3 Ci 8.14E2 Ci 1.80E-2 Ci l.55E-3 Ci 4.54E-3 Ci

1. 99E-3 Ci
2. 61E-2 Fourth Quarter l.32E-2
1. 32E-2 8.15E.:.4 8.lSE-4
  • 3.
  • PARTICULATES Chromium-51 Manganese-54 Cobalt-58 Cobalt-60 Zinc-65 Silver-llOm Cesium-134 Cesium-137 Barium-140 Mercury-203 Selenium-75 TABLE 2b (continued)

PALISADES PLANT EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT GASEOUS EFFLUENTS -

GROUND LEVEL RELEASES

  • JULY 1983 through DECEMBER 1983.

Units Third Quarter Ci Ci

. Ci

. 3.08E-5 Ci 2.73E-5 Ci Ci Ci

1. 72E-6 Ci 1.56E-5 Ci Ci Ci 4.57E-5 Net unidentified beta Ci 2.87E-5 Total l.50E-4
  • Particulates with half live >8 days.

MI0284-0026D-RS02 Fourth. Quarter 3.53E-5

1. 79E-5 9.39E-6.

9~84E-4 3.76E-6 l.05E-3

A.

B.

c.
  • n.

E.

F.

G.

TABLE 3a PALISADES PLANT EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT LIQUID EFFLUENTS - SUMMATION OF ALL RELEASES JULY 1983 through DECEMBER 1983*

THIRD FISSION & ACTIVATION PRODUCTS UNITS QUARTER

1.

Total release* (not including tritium, gases, alpha)

Ci 2.57E-2

2.

Average diluted concentration during period

µCi/ml

9. 38E-10
3.

Percent of applicable limit Liquid Waste System 1% of MPC 1.21 TRITIUM

1.

Total Release Ci 4.79El

2.

Average diluted concentration during period

µCi/ml

1. 75E-6
3.

Percent*of applicable limit Liquid Waste System 1% of*MPC 5.83 DISSOLVED & ENTRAINED GASES

1.

Total release Ci 6.75E-3

2.

Average diluted concentration during period

µCi/nil 2.46E-10

3.

Percent of applicable limit Liquid Waste System 1% of MPC 1.07E-2 GROSS ALPHA RADIOACTIVITY (total release)

Ci

<2.74E-2 VOLUl'iE OF WASTE RELEASED (prior to dilution) liters 2.04E6 VOLUME OF DILUTION WATER USED DURING PERIOD liters

2. 74E10 PERCENT "OF APPENDIX I ANNUAL LIMIT 6.74E-1 MI02S4-000~E-RS01 FOURTH EST TOTAL QUARTER ERROR %

4.BOE-2 7.24 2.81E-9 1.17 4.86El 4-.1 I

2.84E-6 9.47 10.4. I

<1. 71E-2 1.52E6 1.71E10

1. 02

NUCLIDES RELEASED Cesium-137 Cobalt-58 Manganese-54 Cobalt-60 Cesium-134 Barium-140 Lanthanum-140 Chromium-51 Cesium-136 Niobium-95 Iodine-131 Silver-llOm Zirconium-95 TABLE 3b PALISADES PLANT EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT LIQUID EFFLUENTS JULY 1983 through DECEMBER 1983 Units Third Quarter Ci 6.59E-3 Ci 7.92E-3 Ci

1. OlE-3 Ci 7.15E-3 Ci l.94E-3 Ci 1.58E-4 Ci 9.36E-5 Ci
2. llE-5 Ci l.89E-8 Ci 3.04E-4 Ci 2.98E-5 Ci 2.26E-6 Net unidentified beta Ci 4.19E-4 Subtotal for Period (above)

Ci 2.57E-2 Xenon-133 Ci 6.75E-3 Tritium Ci 4.79El Grand Totals 4.79El MI0284-0026F-RS01 Fourth Quarter 7.75E-3 2.87E-2

2. 14E-3 3.99E-3 5.28E-3 7.06E-6 1.65E-4 4.80E-2 4.86El 4.86El

TABLE 4

.PALISADES PLANT EFFLUENT AND WASTE DISPOSAL SEMIANNUAL.REPORT SOLID WASTE AND IRRADIATED FUEL SHIPMENTS JULY 1983 through DECEMBER 1983 A.

SOLID WASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL (not irradiated fuel)

UNITS

1.

Spent resins, filter sludges, evaporator m3 9.25El bottoms, etc.

Ci 2.39E2

2.

Dry compressible waste, contaminated m3 2.89E2 equipment, etc.

Ci 6.39 3

Irradiated components, control rods, etc.

m3 3.30E-l (In-cores)

Ci 2.53E4

4.

Other (describe) ms Ci B.

SOLID WASTE SHIPMENT DISPOSITION Date of Shipments Mode of Transportation Destination 8/25/83, 9/1/83, 9/9/83, Truck Richlanrl, WA 9/16/83, 10/3/83, 10/7/83, 10/12/83, 10/18/83, 10/21/83, 10/27/83, 11/4/83, 11/22/83, 12/1/83, 12/7/83,-12/13/83 7/18/83, 9/24/83, 11/3/83 Truck Barnwell, SC 11/10/83, 12/9/83 C.

IRRADIATED FUEL SHIPMENTS (DISPOSITION)

Date of Shipments Mode of Transportation Destination NONE

  • MI0284-0026G-RS01

General Offices: 1945 West Parnall Road, Jackson, Ml 49201 * (517) 788-0550 February 29, 1984 James G Keppler, Administrator Region III US Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, IL 60137 DOCKET 50-255 - LICENSE DPR PALISADES PLANT -

SEMIANNUAL RADIOACTIVE EFFLUENT RELEASE AND WASTE DISPOSAL REPORT - JULY THROUGH DECEMBER 1983 Attached is the Semiannual Radioactive Effluent Release and Waste Disposal Report for the Palisades Plant covering the period from July through December 1983.

This is submitted in accordance with 10 CFR 50.63a(2) and Technical Specification Section 6.9.3.

Brian D Johnson Staff Licensing Engineer CC Direct.or, Office of Nuclear Reactor Regulation Director, Office of Inspection and Enforcement NRC Resident Inspector - Palisades Attachment OC0284-0015AA-NL02 5 ino.i1

/~l