Seismic Design Evaluation of Palisades Unit 1 Main Components
ML18046A854
Person / Time
Site: Palisades 
Issue date: 07/31/1981
From:
ABB COMBUSTION ENGINEERING NUCLEAR FUEL (FORMERLY
To:
Shared Package
ML18046A852 List:
References
NUDOCS 8108110536
Download: ML18046A854 (109)


Text

{{#Wiki_filter:* Seismic Design Evaluation Of The Palisades Nucelar Power Plant s1os110536 8Io863\\

  • PDR ADOCK 05000255 P

PDR

  • Unit 1 Main Components July I 1981 Combustion Engineering, Inc.

Windsor, Connecticut

Title 1.0 PURPOSE 2.0 SCOPE 3.0 METHOD OF ANALYSIS 4.0

SUMMARY

OF RESULTS 5.0 APPENDICES Table bf Content~ A. REACTOR VESSEL REANALYSIS B. STEAM GENERATOR REANALYSIS C. REACTOR COOLANT PUMP REANALYSIS

rt x. n**oe

  • r'tl
  • PURPOSE:

This report presents the results of an evaluation of the reactor coolant system main loop components for the effect of higher seismic accelerations than used in the original designs, in accordance with the findings of the Systematic Evaluation Program reported in NUREG/CR/1833.

2.0 SCOPE

This report provides results 6f analyses of the Palisades Nuclear Power Plant Unit 1 Reactor Vessel, Steam Generator, Reactor Coolant Pump and their integral supports. 3.0 METHOD OF ANALYSIS: The original component stress reports were utilized to determine the areas of maximum stress. These stresses were then recomputed using the new seismic accelerations. The new resultant stresses were than compared to allowable stresses to determine acceptability. For the reactor vessel, analyses were performed at the outlet nozzle, the inlet nozzle and the support lugs. The original stress report did not separately list the input loads for pipe* rupture and seismic; the two were surrmed. To be conservative the sum of the pipe rupture and seismic 1 oads were *increased by the largest ratio of new seismic acceJeration to original seismic acceleration (i.e. in the vertical direction.34g/ .* 312g). For the steam generator, analyses w'ere performed at the primary structure (support skirt) and upper support lugs. For the nozzles and support skirt, new seismic loads were generated by applying the new seismic accelerations (.64g horizontal and *.49g vertical) to a computer model of the reactor coolant system utilizing the

  • MEC-21 piping flexibility analysis program.

For the upper support lugs, the original seismic loads were increased *by the ratio of the new seismic accelerations to the old seismic accelerations {. 346g horizontal and.133g vertical). Resultant seismic stresses were combined with the pipe rupture stresses at the inlet and outlet nozzles. Seismic stresses were considered alone for the primary structure and the uppe.r support lugs. *All resultant stresses were then compared to the original. stress allowables

  • For the reactor coolant pump, the pump volute, inlet and outlet nozzles and support lugs were investigated. The original seismic stresses were increased by the ratio of the new seismie accelerations (l.27g horizontal and.34g vertical) to the original seismic

accelerations (.55g vertical and horizontal) the maximum stress intensities were then conservatively calculated by adding the new seismic stresses to the original pressure and thermal stresses. The combined stresses were compared to the ASME Code S:ection III Par. F-1323.1 allowables. 4.0

SUMMARY

OF RESULTS: At all locations the new stresses resulting L -*--~ from the new seismic accelerations were less than allowable stresses. The existing designs are therefore capable of withstanding the new seismic accelerations.

~ =iJ POV./ER ~L::J SYSTEMS

  • C01.IBUSTION ENGINEERING. INC

,L/ PPEIV DIX A-I Page Number A

  • SEIS/'11C RE41VAlYSIS o~ //-IE

~ONSUMB:R..5 PoW£R RAC:.Tt>!C VcS<.5E"'L SVt11'11-/12y Or l<ESUI.. T.:;;, .Il'llcl lv'ozzLe (P111<r I)

  • I!Vt.T /(OZZL.G' ( P~12-r.zi)

Oun.Er !Vozzt..E (PARr I) Ov1Z£T J./ozzL * ( PA!CT -2Z) VE5SE"l..SrJPPCJRT3 /JH/9LYr/C4L Rc-Po.Rr K'C:-F£REN'eC:.S A-2 ,L} - 2 A-.3. A-5 A-7 A-9 A-12. A-1.3

0"""~a POVJER .. f -- SYST 1-!\\*~s ~,,;:.a

c. Ii/I C...,"'t,4BUSTION ENGINEERING. INC.

Rct9crDR (cs.5EL !f_E/.HOD o;:-* IZN171.Y51.S A-2 Page Number ti

00111 C.E;.;C-/116

'/JN/-JlY//C/'11L /f£POZ-r' FOR I.,,

  • Co/IJSUH.RS. POhlcR R&9C'rc;,e V5SE"L '.' //-/£,LJRG"AS oP SIGN1P-IC'4l~~.SIR55 ~R' IOeV//,&/eD., /t/EW
9CC/l)£/r//"'\\C0'4DS ARc V.ScD 'TO Rc~()f'1PtJ/c "/#C
:-

SIGN/F/t1/JN.,-.::;rREssc-s /91'JD //-/C'.5e ;'fRc 7/-/c/'i/ co11PAJ2]) 7() ///E OlflGIN4t. t9t.t..O.JVABt..c 57RS.:Se5.

  • uN/:"~tertJN4/ct.Y -rr15 AJ/Vl'49t.YTJC"~t...Rft:>RT Z>0..5 NO/

0pic1FY n/E SEl..5/-1/C /NP(.)/ t.OADS ScPER/lTEtY ri<Ol'1 "71-/E n mt.. r9tc10E1Jr ~o/JO..S*. /o Bc- {'oN.Scte Y'4T/YC 7#c C/'~1"7/Rr- /9eC'JOF./i//' LOAD JS 1NC:REFJScD BY /#c- ~'1.eGc-sr*,;f"9//0 or- /VEN sc1s/v1c /lCCt.E12.,:;110N 70 02/G/.NRL 'SEISH1e r9~C6 Lce4T/()/..J, /h'/s //"9PPt=Ns ro sc- '?'#c VE1CT1<1AL D1R£Cr/OAI .S£1SHIC Rt4TID. or-o3~q/.312Cj- - J#c-..ec- "'9Kc 7#.Rc~ 'C.acA?=/oNS A/VAt.'r'Zc-o ! 71(_ /tVl/ NOZZl.£.1" -r/-IE c;u,72cr /V'o-ZZt..G A/\\JO 7/7'6.: SUPPoR/ ?/905,., SVHHt9rC.Y o~ Re-suL rs : FOR l)ll, t.OCA /IONS /h'S-NEW.:SJGNIF1~Al\\/T SltfSS5 "'9Rc L..:S..S "Tr/AN OK t=t;>Ol7L TD /r-/c/R

  • 4LLOrlABl5.
  • *.4cc1oeN/ =

(PIPC BRCl"I< SSE :sc1s1*11C)

  • --...~-... -~~

-... *----......-----*--------~--------*--- ~ POWER ur-SYSTEMS c ENGINEERING. INC 4-3 Page Number ..Z:NLE/ /t/ozzt.E (PrtR/ _r) FRo,....,1 */#c s1C/V/;&/CA/Vr fifc-s1.1c.r~.<FJ A-13) zyc:- GENER,-1/t. ~vs LOCAt. P£111,,..7,ey s/:12c-ss /N'Tl:Als11 y l/V' //?c. ye-sse t. raLt. /.s /Yos/ c:::7R/T/C"'9L Ar Lc;CAn~/\\/ * ~ (oors1oef) OF 1/1/L~r NOZZt. /10, _,, M//-1 ~c-F:e1cT1aA1 Fo1ecE..s /-l cr1/'/c;; ~01At.Lr Ou"J';' ,,&;e!Jrt s_l-/ec-r /1222 (P:J A-JS) ()dt.Y T//c lJCSIG/\\J P/~e ¢ svProter Lo~os w1Ll. 8~ //VcRc/7.SD //-/c DSl6/'J PRGSSUe~ Si"~e:ss~.s HI(./.. REM/111\\/ -rdc-* SAHC. @ Bu ~ (DE.SIGN PRe.5SVR9 =. 7,~~ )(.SJ I ~\\.~~ v; (or=.s1c;,tJ P1Pc I ) = ~0,7t-l.79 rtJ..3.S-r-t:~4_,;.312 5VPPOte/ LOAD.:J>

7-50 Jcs;c:l\\J PIP f

=(&S5"r2.-l.S-7/.22rZC,!J,312 .5()PPOR1" ~OAO.S)

7.~4 KS/

v;. (To/Al-) = 3z, so+ 7, -1'-r:: 3 f, 94. KS I

h~PO:[t!~R ~-osv~rcMS COMBUSTION ENGJNEERING. INC

  • J./.;t.c T No2zL' (P-4teT :r C'1NTo)

...34

o. 81,312 = (),88 KS I lt-4 Page Number

= 39, '?7 /CS I < /,.S-Sn-i :: ~o K5 I

, :tm..J2 POVJ.ER !:.-i..s* SYSTEMS

  • --.OUBUSTION ENGINEERIN(!. INC A-5 Page Number TNL£T JVozzL£' (FART;_.zr)

FRoH /HE S1G/'.J1F1C'.L1Nr Rc~UlT..S (sec. s:o90. c) (~A-lh) 771c /l#JX//Yt/"'f NE11'1B/?ANc T BEND/IVG STR:55 /N/cNS/IY JS //\\) /#' Ycs.SEL H/9LL /tD..V7C'~/V/ T'D /dt.T /YOZZt.£ #0 OF R~FREiVCE 22 (iCCA710/\\J BL) !=Ro/If SllcE/ A-230 (f:jA-18) ; 0111.:'.Y /'//(" /;1,.l/~h-4'///l"V".1 h".Y?07'/-/CT/C"A(. .-icC'/OEl'17)__ L040.5 hllt.l 8£ 1NC!t<C:-4SeD. rh"E DE.SJC/'J ?,eE.SSlJK:.:5TK'E.SScS )Y/L.t.. ,K>C'~-4//\\/ /Jlc :SAHE, @BL Yx (Dc.SICN PR e'.5.s) =

  • r 7, ~ KS I

/ ~-(* ~-~ ~ i../111~ PIPc LD'1o-V-: -;. 7r~-"'1'-0.~ -r~.:,;,.3iz = ;-9, 3 7 K.51 pX (/OT/flt) = 7.-t' r ~3 7 :: /~. 77 KS/ f{;.. ( DcSICN PRE~s) -:: T-..32. 5 A'S/ l'9 (!11fA PIPE LOAD::.) =-(-,1.~>'6.0-2.0 r -a).'/;~

7. f/,KS I y"& (lo7/IL) ::.32,.S r 7.4'/ ::- 39,9/ KS/
  • MH;C} =:: {f1Pc.8Rc"7K. +.ss£. :sE1sM1c)

1<Z.,,~ PO\\NER ~.~L.::5 SYSTEMS COMBUSTION ENGINEERING. INC Page Number v; (DESIGN R<css) :: -zs-KS/ ~34

J;.e- :::...3. /. 3 J 2 =-..3. 38 K~/

v;:; (f1;1X) ~ ~ ~v&.;.) (v;,-;sy-r.:r 2 -=- ~ 0.3</,KS/ /1~;< Co11e1tJC.JJ STR£S:S INravs1TY(fM -rPa)-=- ~z .. 89 Ks/ </.!Sy"= ¢5.50-51


~---.

~~POWER d~SYSTEMS CO!.IBUSTIQN ENGIN_EERING. INC OUTLEI NOZZLE' ( P"9,e/ I) fl-7 Page Number rROl'1 me.SJCi'/\\//Pl~r7~r K1£'5()LTS. (f',qGE A-19) //-IE Gc-NER.4C. P~V..5 LOC"7l sr,ec;ss /N/c/\\J.S1T'r' //1/ /'#C VE.:55~l r/4LL /..5NOSI CR1r1Cril /tr too;71c;/v BL (;/l/~1De) <JF O()Tt..e-r #ozzt.£ ~ .. c tl17'1f //-! F~!CTJ()N. Fo,ecr;s /9~77Ak:; /<'9Dlr9L lY //\\/. r.eo11 SH, 4-292 (ljA-21) ONLY /'h'~ LJ.514'/\\/ ?JP!). SUPPORT' LC>t7D:5 rVILL B'c INCREASED. /)-IE DESl6/\\/ PKES:5Ue' c51Rc35C::S WILL R£Mt1JN 7JfE" SrJ/'-fC: @BL VX (D51c;d ?..eess) -= : 7. ~'1 1::.S/ UX(Des1c;N PIPE¥. = (-/.38 +29Z-0.4'1-r43~ SU PPO!e I LOAD.s). = 5.fO KS/ ~ (lorA'-_) :: 7. ~t:, 7-5,90 ::: /3;5~ K~/ v; (0SIGN PRess) = r33,,/G:, KS/ .. 34 '312 VB (o5/t:N PIP ; ..34 SUPPOI:/ L011Ds) = (-o. 95' 7-4. 12 -/, (:,2, re. s1) '312 = -t:-r9 KS I v; (TOrA~) = 33./(:; r f:¢'9 = 37~5 K.5}

"* :!'~PO'NER -*~ SYSTEr!i'is COMBUSTION ENGINEERING. INC Ouru;;- )lozuE' (fl/Rr.IcoNrb) A::_B Page Number Yr (DESIGN PRES5.) = -z s KS I -r .34' -1 x g. "=- O. 41' 5 . 3/ z :: C>. -9'9 KS) st) (tnax) -= \\i)(+-'V& +-~(VX-:,ro..y r::J 2

=: 37,c,,c, KS/
  1. 4Xll'1/)M COl181NED srec-.s5 ),F\\)rc/IJSIT'Y =

~/..S-Sn-i ~tt?,/6' ~5/ - 40,t"S/

  • ' 51NCE /He-Ds1G!V P/PE ~do soPPoer ~OADS

/NCltJD (Rc.F ~ A-22) :.. 1.) SvPPor(./ RE"9C-t!t~r11s ove-ro L:Je-Ao r/£/t:;Nr or R. J( 2~ Svt°fiY.:1 ((. c/Jc110NS DU~ ro coN-r,eot. Roo :5Cf:'A/1.f. IJ£'11D r/£14/./I j='/,&>/4($ K'~-4t'T/tJl'l/S <PIV /I/OZ' Z~ 5, Cow 5P1<1.vC//vc; Racr;"/1/s oF P1P11Vq ON /Vozz t.£5 F1C1Cr/o/v'4L. EFFEc/" or-P1P1/\\lc;-.t;/l/O ~ v. 5uppo,e/- c;~orlT,4/ Kt/le T7c;/1(5', PJ,o;dc; jf~;-J{'T/CrvS ~r /t:;O% 4'>/tER. £)~51c;f\\I 5£1.S/1/C /'(OZZL.6 t9ND SO/JP(),Z/ /?Ct9C7/~VS, ':~ I/ ~/lN. _8G /9.5SUH£0 /#rl/ 7#.£".IC::, KSJ INC~~A2:~ S'Tt<ESS /.s )"I; l/llN /NE CotJSe RI.IA T1s111 ~c6C.Jt:.7/rtlG F~,,v/ /NC;cFAS!lvC. "9lt. ~F /"HC,4/3.JV~ ~t)AD.S /,V-sre.10 or.:ru~7 /HE OE:SIGlU s~*1SH1C,

~~ C:2 POV/ER

.i~.SYSTEMS COMBUSTION ENGINEERING. INC I..,

A-9 Page Nuinber 0UTL/ /'/ozzt.C:- (P!7RT..zr) Fteol'-'I /h1c ..:s1GtJ1FicA~Jr !?ESUL.T.:s ( se::c. s,120, c) (f?cJ A-24) 1#t: !'frlx1HVH COH/!,llVED !VEH.BRAN6 + BE/\\JDJ!V(j .SrRc-ss 1N-re.1Vs1TY 1.s 1,v Ir/<£ rc-.:s.sc-L :siHt:u,.,t:;r r.1-Jc-7?:JP oF /"#tr /l/OZZl.E ol'c;V1N~ (Lootr1CJN Al-).. zy~ rJL~WAt3t. NEM8/2ANG' + 8ENDIN<:; S /R£.Z- //Y/f'/s1 r/ /5 13ASe.D ON L/M1r DESJGN /H£f>R.r:' ~ - HOM 5Hcel A-300 (\\) A-2~) ~ ~ ONLY rl/ H#A ~Ml}X/i11./H flYPOTH71t1At. ,4~~1!::£v-r/ P;Pc LOADS YI II. L 13 lll~RE.-9St:D~ -r-HE DcS/G/\\/ PK'c~JRe SrtR.sscs rt1t..1.. /<H~1N /'r/c sqnc, @.AL r; (0E5tGN PR.ssuec) ~+;;: 7 Ks/ °VX (t1Hll PIPE t.OAD): f.S:5+J/]r~/-.36.~.41z = - ea..3 3 J::Sf ~ (7?JrA0 -= 7 28. 33 = -20. Ct;.3 K~J tie. (D£~1CN PR£SSU'i?E) = -;. 33, C. K~I ~ (11HA PIP LOAD) = (-.3,8+/t:,.S-rl.3,5-21.J) .S:23 K~J V@ (Tom L) = 3:3, z -r s: 23 -=.38.. 4..3 ~s 1

  • 11/iA:: (PIPE' Be£"11<+ :5:5 5£JS111c).

. 3*~ o~ ,312

-;-~*POV/ER

~~L..::5 SYSTEMS COMBUSTION ENGINEERING. INC /J-/0 . Page Nurriber OU/Lt=/ J/ozzL.E (PART I[ coNrb) V7 (CE5;c;.v PREs:s) = - Z. S-.KS I ( .34 -V;t.r; /VIA PJPE LDr7Dy = - 0, 7 :3JZ = 0. 7h KS/* vx +re I IVX.- 'V@'\\ z.

?_

2. +'\\f \\:. z / +-.::r ..38..,t'G Ks I r..eo11 SNc:e-775 A-30/ f. A-302.* (f3~ /1;..27. ¢ lt-28) t.oi..£fl~c. Srass FOR CbHB1NED Hc:HBRAAJ~ r' 8tJD1A)q /ic111~ ONLY /17c; /'11-/A LOADS Nill. 8' l/11C.c-15GD. Ji; (Dr=.51c;iJ PRcssoee) = _T:?. 7 ~SJ. / "\\ /.. ,,\\ ~ l7X \\/1H>i P1P1E ~At:J== r...-5.5 r--1( ~.312 = -/.5..3*"K5/ D°X (TOr/1L) = 7, 7-/.53 =. 6,/7 KS/. VB. (05SIGN. PRC.SSURE) = 7!-.,$3. 2 K:5 / ..34 19 (11/./~ PIPE c..o,qn)= (-3.8 +13.s).-:3/z::; /0.57 l1) = 45.5 t::.5/ e ~o°F . p~ ~ "8C.7 D. (/h1Ps)/'sr:> =.1.30 (:5E Cl)Kl/e 13,4-27) f Pn, t~)lit.LOWllB'e = 59./5 ~SJ >~"°Pe\\

=. 59.0b ~I

\\.:._ Veht.e()UJ TED

~POV/ER i.t~ SYSTEMS COMBUSTION ENGINEERING. INC A- /'2. Page Number VESSEl

  • SuPPORIS FR0!-1 lflE" :5JGNIF/CA/// RE"SUL./S

(~ A-29) I 1"1/'9XJHVH C!.0!113/f'/ED PR!HARY Sl'RS.S (BEND!Nq' + COHPRE'SS;oN) ~- + Q$ = Z4,5 KS/ ,./ .34 n/VS-rRes~::.31Z xz.(,5~51-= 2~.7KSI </.SSh? -::: f't> KS/ ff !1rtx111u11 CCJ1181N~D ?R11-1ARY S1R.:-.ss ~R A~1ocAJ/ Co11017/0A/, ~ +vs = 5a o KS/ .~~ I Al'cN sr.ec-ss =,312 x 5tJKSJ =.5~-11'9..<s/< z (Sr +Sv)

. 60,7 KS/

.llT /11'9X/t1UJ1 SHclJR STRSS DVRJNCj ACCIDENT CtJ!lorr;oNs ~:: /~8KS/

  1. ~rv ST,e£:ss =
  • 3~ x. 14.8K.51 = Jb.J3 K~_/ < ~(sy_-r..s,,\\

,312 '-',,}

30,C> ~SJ 1--------------------- *---...----~-*****

J he

~

PA6~ A-I~ 5.080 INLRT NCZZLE (PART I) I\\. Abstract

  • \\.

Th.l:;; a11alysls presents the structural evaluation 1.">f' the inlet noz~le.s for d~slgn coridi tlon~. Stresses* con::)ider~d are th1.)se r~3uJ t I 11g fr*l"*m in t.ernal preSl:!UI'e, pipe I'~Jct 1011s, support lu:.Hi.111~, a11d enrt11quake loadl11g. (s.... ~~ t*heet.:J A200 thru 1\\222 of /\\ppf~11cUx I\\ J'CII' dt*la.lled :rn::ily;~Js.) B. Gc~ometry ---J..,, _ Nozzl:__ _ Cut 3 Cut 2 Cut 1 C. Slg111f1cunt Results The reuctol' vessel ir1let nozzles are simultant!ously acting design loads. determ1r1ed in this analysis are less bles. J Vessel A.. A,, I I \\ \\ l I D \\ \\ ~ J--+:--:.1:.l a.~ 1lt ~ 10,,,...._-G-=~li \\ \\ I I '~/.... '"'""~--~- 8L. e,,, a de qua te to withstand the* All stress intensities than the required allowa- ~ -

,.i

5. 080 HILE'J, NOZZLE (PART I)
c. Sig11.if'icant Reaults (Cont'd)

'l'he most cri t.lcal ~eneral primary membra11e s t.ress 11°1te11s1 ty in au itrlet nozzle occurs ~t Cut "l". Th18 s L.ress l11te11;:;.l t:.r of' 13. 75 ksi (see 3h. A218) is less than the Sm allowable 01*

17. 4 ksi.

The most cri tlcal g;~nerctl plus local primary st:res3 intc113l t;-.* in th1~ no.zz.les occurs at Cut "3" (see Sh. A220). 'l,hls ~t.l'e*~:..~ lntens1 t:r uf 12. 7 ksi is less than the 1. 5 Sm allowable.._.,f 26.1 ksi. The most critical general plus local primary stress intensity in tne vessel wall occurs at location Bu (outside) of inlet nozzle No. 4 with the friction forces acting radially du r. This stress *intensity of 39.4 ksi (see Sh.* A22a) is less than th~ 1.5 Sm allowable of 40 ksi. D. Discussion of Analjsis This calculation demonstrates the.adequacy of the main coolant nozzles to serve a.s vessel supports in addition to perforining their primary.func:tion. The nozzles with support pads support the dead weight or the vessel and sustain the loads due l.(> pipe reactions and earthquake. The 3upport n_ozzh*s have flat pads.integral wl th the nozzles. The ~upport pads :ire assumed 1D be free to move radlallv on the M bear*Jng plates but guided to prevent rotation of the vessel

  • I I I I

l -.... :.. *. ~:;;,..;....:;... ;;;:.- .,,,;;w:-o;,.,,, ~,.,.,..,,;;,,:W-'"'""""",.... -~!----,!....,,.,. *... :, **.. '\\' ut-I... /et*,."1!* 6")";,<<~-* oui" GENERAL -AL PRIMARY STRESSES (KSI~ sra:s OAD * ::> 1 RESS EQUATIONS Au AL u BL Cu CL D11 DL 'DESIGN PRESSl2.q6BOI p or* 8. 73qqB p 7.42 + 7.42 + 7. 4-2 7.42 I+ 21.85 +21.85 +21.85 +21.85

NfFY/Rwi
  • t-i</Rmt

+0.10 +D.70 -f-0.70 +O. 70 ~0.70 t0.70 +0.70 ~0.70

  • DESIGN M.YFt.* 6F.>)ltZ fl. 7q -1. 7'( +I. 7q -1.1q +I. 7'f -/.7q +I. 1q -J.1q ax* PIPE i N1My/R!P* My/R!.Pt. ~

~ ~ ~ +0.24- +0.24- -0.24- -0.24 SLJPPORTMYMy/RmP*6MfRmPt2 --........._ ~ ~ ~ ff-J. 33 -1. 33 -1. 33 t I. 33 LOADS. N¢M?/R~,P

  • M2/~~/Jt.-o. 35 -0.35 +0.35 +0.35 ~

~I~ ~ MyM:/Rm/?

  • 6;~¥'R...,Pf!-4-. 04 +4.04 +4-.04- -4.04 ~

~~ ~ TOTAL ox + 5.52 +I0.02 tl4-.30 +2.64 f25.qJ +l'l.67 +-22.17 ~21.85 loESIGN PRESSh3.00l61 p or 2.q6ROI p +32.50 +32.50 32.50 +32.50 +7.42.f-7.42 + 7. 4-2 + 7. 4-2 1N'¥Fx/Rm

  • FY/Rmt

+0.55 +0.55 +0.55 +0.55 t0.55 +0.55 +0.55 +0.55* . DESIGN M¢i/Fl< * ~Fxlt'2 2.4-5 -2.4-5 +2.4-5 -2.4-5 +2.45 -2 4-5 +2.4-5 -2.4-5 oe PIPE$ .IN'b*My/R~p, MfR!P.t. ~ ~ '*~ I~ +0.13 +0.13 -0.13 -0.13 SUPR?RT MiijM>IRmfl' bM>jRtv1(1f! ~ ~ ~ ~ 2.26 -2.26 -2.26 +2.26 LOADS N1:Mzi/~~p. M~/R~/Jfl.. -1.22 -1.22 + 1.22 t 1.22 ~ ~ ~ ~ Mi/M-;/R.... P

  • 6MlfRrnfJt2 -2.61

+2.~I + 2.61 -2.61 ~ ~ ~ ~ TOTAL 00 t31.67 +31.'i'I t3q,33 +2'l.21 +12.BI 3_3q +8.03 It 7. 65 or D~lGN PRESS -P,O 0 -2.5 0 -2.!i 0 -2.5. 0 -2.5 DESIGN PIPE MxJ21rro2t +0.24 +0.24. +Q24 +0.24 +Q24 +0.24- +Q24- +0.24 JX9 l SUf.'PORT Fi-/1fro t -0.57 -0.57 +0.57 t0.57 ~ ~ ~ ~ LOJ\\DS Fy/1frot ~-*~ ~ ~ -1.06 -1.06 +I.Of> +1.06 TOTAL Txa -o. 33 -0.33 +QBI +0.81 -0.82 -Q82 +1.30 +I. 30 s...,rmn) =Ox~ 09 + W";: d~J1* + :rz. +31. 68 32.02 +3q.36 *+2q.JB +25.qh +/q, 71 t22.88 +2/."11 c;~r,. \\) = aw ~~tti:vr~~J2+7z +5.52 +q.qa t-14-.ZB +2.66 +12.76 +3.35 +zqz +-7.53 ~. hl1n 2 i~Ai'.1~1UM lCM2!NED ~TRESS INTENSITY t3/. 68 rt 34-.52 +3q, 3b rl-31.68 +25.q6 +22.21 f+22.88 1+24.4 7

5.090 INLET NOZZLE (PART II) A. Abstract T}1.e purpose of this analysis is to investigate the main cool-t.J:* *, lnlet nozzles under maximum hypothetical accident con-di tlons where a safe shut down of the plant is necessary. (See. p, A223 thru A230 of Appendix A for detailed analysis.) B. Geometry I C. Significant Results

  • The moximum membrane + bending stress intensity was found to be in the vt--ssel wall adjacent to inlet uozzle #6 of Refer-ence 22,, (Loc":a t.ion BL).

The nrnximum stress intensi 1..y (Pm + PB) = 42.l ksi was found to be less than 1.1 $y = h~,. 5 ksi for SA-302-B material at design tempera tur~ 01* 650°F. It is, ther~fore,, the conclusion of this report that the in-let nozzles will resi~t the impooed loads under MHA con-ditions

  • PAL?E J}-17 D. Discussion of Analysis Sir1ce two of 'the inlet nozzles function as supports for the reactor ves3el, it is or particular interest to insure that there will be no gross failure under MHA condl tions.

Both the nozzle and vessel wall around the nozzle opening are 1nv~st1gated for pr1mar,y load carrying capabil1 ty. The maxi-* mum combination of membrane +bending stress is limited to 110% of minimum yield strength at design temperature. It is of part.icular interest to riote that the 11ozzle cross-section experience*s comparatively *low membrane + bendit1g Dtress while local regions in the vessel wall *around the nozzle opening exp~rience~ -the highest sires:S<.->::>.

~,, ~I I I i .I I I i

\\.* i ~ 5.110 OUTLI*:T NOZZLE (PAR'r I) fl.. Abstract Thi:J analysis prese11ts the structural evaluatiLn1 of.' the 0ut...; let nozzles for desigt1 conditions. Stresses c1.mside.red are those resulting fI'om inte.r1Jal desig11 pressure and desig11 plpl~ load3 and support reactj.ons. (See Sheets A269 thru A292 of Ap-pendix A for de taJ led analysis. ) B. Geometry --~ Nozzle Cut 3 Cut 2 --- Cut_]. J Vessel I I I C. Significant Re3ults '11he reactor vessel outlet nozzles ari= adt:?quate to wi thsta11d the slmul taneously acting design loads. All str*ess interis1-tles determir1ed in this analyuis are less than the required allowables. I

.. i PAG A-5.110 OUTLET NOZZLE (PART I) C. Significant Results The most cr:1 tical general pr11)1ary membrane stress lntensi t~" in an outlet. r1ozzle occurs at Cut 111 11

  • This stress i11tens:t l.'.~

of 14.17 ksi (see Sh. A289) is less than the Sm allowable of 17.4 ksi. The most critical general plus locaJ. stre.ss 1ntens1 t.y ln t11e 11ozzles occurs at Cut "3" (see Sh. A291). This stress in-tensity of 13.7 ksi is less t.han*the 1.5 Sm allowable or 26.1 ksi. The most crjt1cal general plus local stress intersity in the vessel wall occurs at lo ca ti on BL (inside) of OUt~le t nozzle No. 2*with the friction forces acting radially in. This stress intensity of 39.8 ksi (see Sh. A292) is less than the 1.5 Sm allowable of 40 ksi. D. Discussic:'ln of Analysis Thls calculation*dernonst.rates the adequacy of the main cool-a11t nozzles to serve as vessel supports in addition to per-forming their prlmary function. The nozzles w:ith support . pad.u support the dead weight 01' the vessf:!l and sustaln t..he load~ due to plpe I'ea<:tior1s a11d earthquake. The support nozzles have flat pads integral with the nozzles ac shown on Sh. A270. The support pads are a1:1sumed to be free to move radially 011 the bearing platesJ but guided to prevent rotation of the vessel

  • 2.0

I .,;... ::_ **. "..!;........ : ~*.: *.* ":-:,;;; *~:.:::"!":.*... *-~---;.:;::.- :""-**.. --... -*.. *---* I 4 OU I LET N. 2. *_,u R. cu -.

o.

I '"' GENERAL + -AL PRIMARY STRESSES (KSI~. ~R:ssj ~ lAD [STRESS EQUATIONS Au AL.

  • -= BL Cu CL
  • Dv DL
  • DES!GNPRES53.0637'1Por'l.ooJBI P +7.66.f7.{,{, +7.{,6 +7.{,6 f22.50t22.50+22.50 1t22.5C l IN:IF>i./Rm
  • Fxf.~mt

-I. 38 -1.38 -1.38 -I. 38 -1.38 -L38 -1.38 -1.38-DESIGN IM.¥,::-,y

  • 6F>f'tZ

-2,q.2 +2.q2 -2.q2 +2.q2 -2.q2 +2.q2 -z.q2 +2.'12 o; PIPE i NyMy/R!P'

  • My/R°fnPt ~

~ ~ +o.53 f0.53 -Q53 -0.53 SUPPORTt 1YM~(RmP* 6MJ/R111Pt2 ~ ~ ~ ~ +2. J t -2. JI -2. I l' +2.11 LOADS Nx,!M1/Rn~P

  • Mr/R~/Jt +o.4q +o.4q ~o.4q -o.4-q ~

~ ~ ~ MyM1/R~P. {;tv(fRmPe +4. 36 -4.36 -4.36 4-. 36 ~ ~ ~ I~ TOTAL ox +8.21 +5.33 -1.,f.q +13.07 +20.84- +22.4-G +15.56 +25.f>2 DESIGN PRESsll3.2634-4-P or 3.0~37qp +33.)6 +33. 16 +33.16 +33.16 +7.66 +7.66 t7.66 +7.66 iN*.Vr-x/.Rm

  • F>VRm t

-o.q5 -0.'(5' -o.q5 -O.Cf5 -o.q5 -o.q5 -o.qs -o.q5 DESIGN M¢/F"

  • bf!"x/t.2.12 +4-.12 -4.12 +4.12 -4.12 t4.l2 -4.12 +4.12 oa PIPE $ Nt/My/R!.P* M)f'R:;Pt ~

~ I~ ~ +0.28 fQ 28 -0.28 -aze SUPPORT fVl'VMy/RmP' bM>/R~{l~ ~ ~ ~ ~ +3.81 -'g.8 I -3.81 +3.81 LOADS No/'Mzi/R.~P

  • M;/R!a P'f'- +I. 62 +I. {;2 -1.62 -1.{;2 ~

~ ~ ~ ~ 1*1/t4-;_LR.JJ

  • 6M.iRrnP t2 2.57" -2.57 -2.57 +2.57 ~

~ ~ ~

  • TOTAL 08 t32.28 +35.38 +23.q(J +37.28 +6.60 +7.30 -1.50 +14:36

.ar DE"SIGN PRESS -P,O 0. -2.5 0 -2.5 0 -2.5 *o -2.5 DE~IGN PIPE ~X/27rro 2 t +Q03 +Q03 f0.03 +0.03 +0.03 +0.03 +0.03 +0.03 Jxe ~ SUPPORT Fi-/1rro t -0.4-2 -0.4-2 +0.42 +0.42 ~ ~ ~ ~ I LOADS FY71frot I~ ~- ~ ~ -0.73 -0.73 +0.73 +0.73 TOTAL Txa -o.3q -o.3q +0.4-5 +0.4-5 -0.70 -0.70 +0.76 +0.. 1b llin(mav.):: ~~a-, +V,iU-t-"'.4.Jl+ :r2. +32.28 +35.38 +23.'IO ~3l2B 4-20.97 +22.4~ +15.'Jq ~25.67 i~. , i) _ crv -r CTA_\\jf-.,, -u,.f +Ji! +0~20 +5.32 - I. 50 + 13.06 '+6. 65 +7.27 -1.53 +14. 31. l-1:.!!>:1n - z

z.

if'*;A>~ii~11)M CCMPINED STRfSS INTENSITY +32.28 l37.8B +25.4-J +3q.1q +20.87 +24._lf q +17.12 +28.17 n o J: > Pl -i. 0.,.. z c i::: m Pl

u I

~* .I 1~~~~~~~-#1~~~[~~,~~~:;~~;;~<;'7~3~:~i\\j I

~

  • i DETAILED ANALYSIS

! t SYSTEM GEOMETRY f -* i ' 1 r*. i i ;. f I

f. ;

~" I i ! I t

f.

The fol1owiYiB s~etch is of the outlet nozzle: l . r-~--i-u-~-~ v I 11 2tooo I, **

24.000 34.28125 25".3125 L

I. ~* I 1* I . I j Rv= If I. 625" I I. . I r--J I. L--, I., L----~--~-.J 36.2812Su* SYSTEM. LOADING In th; s analysis; the. *outlet nozzle. ~;JI be.* i~vest*gated under design load co11ditions. Tne desig~ loads are: I. Design P,ressure.. = 2500 Pasi Desigri_ iewiperature =.650 F

2. Desi9n ~ipe loads avid suppp.rt loads : *...

Support reactioVl.5 due.. to aead : weig~t of R. v. Support reacTions due to control rod" scram. DeaCJ

  • weight pi pi;igL_ reactions. on
  • nozzles.. *
  • Cold springing reaiTions *of PiipiY.>q on nozzles Frictional effect of pipinq ar?d -RV.

COMBUSTiON ENGlNE:ERING, INC. ENGINl!:ERINQ CEPARTM£NT, CHATTANOOOA, TENN* CHARGP.: N0_2q ~-""6_-_,_A...__ __ NUMDltH e1 c*

  • w_a._..:.* *...,,
I
sHcrr 5

ry,._2._ G co~. a..n4-18-67 ..,.JQbl'.lsor~ SNGINEO C!:SCRIPTION ST R!)GIVRAL AtiALVSJS._Q.._F __ OUTLET NOZZLE CHECK DAT~4-- M-67 ovHus1!e1W PAG £ A - 2 3 if" CUGRIPTION_ DET.~ILED ANALYSIS SYSTEM LOADING Support growth reacfioris Pipirig reactions at 1003 power Design seiswiic l'"lozzle and support reacti'otls l SYSTEM

  • ALLOWABLES I -

I I The followiv.g allpwable. stresses are taken from f/,e ASME

  • Nuclear Code J Section J[; ref. 1 ; and are the

~asi~ for _tJ.ii s analysis. ~ .

  • l. The avera~e primary stress intens11j across a I.

solrd section wrust not exceed S,..,., at design I

  • temperature and design pressure.

l I

  • 2. Th~ Joe.al priwiar.Y.. stress alone or co~bined I... with 1 above

~ust noi exceed 1.5 Sm at desigVl tempe raf1Are arid desig~ pressure. i I I I!

  • *3. Thet' prim~ary* b~n. ding ?tress alone.dor combined wi n
  • I 2 above WJusT

~Qt excee

  • 1.5 ~*.at design
  • ey,,perat£Are a~d desigri pres sure.

. I I; ! I [ I I le I ~ 11WWYWWWJ&~.ma::;as2S£iMf~&'4'M-.lt-t~.!tt@tc.:Je::~~'-~r:~~:~-.~*&.%.z;c'r~~~4!c1ttit;h..... ~ DETAI'

  • Il'lTF ANAi.

The divfc 1, 1110Qt~ assi: re du} Slqn E'le~., I.. E\\em: I

  • ~I Elewle-EJewr Elem.

H-, JM, are r fot-t V}OZZ defe;- . analy

.5.120 OUTLET NOZZLE (PART II) A. Abstract The purpose of this analysis is to investigate the main cool-a11t outlet nozzles under maximum hypothetical accident con-dl tions wher~ a safe ahut down of the plnnt is necensary. (See sheets A293 thru A302 uf J\\ppelldlx A for detaJ lNt :i11<1ly:.~is.) B. Geometry I C. Significant Results '11he maximum combined membrane + bendi11g stress intensity was found to be 56. 3 ksi in the vessel shell at the top of the t10ZL':lf.? opening (location AL). Based on lim1 t desig11 theory, t;he ollo 1*mble membrane + bendirig stress intensity was found to be 60 ksl for the critical stress pondition. (See Sheets A 301 t.hru A302) * .I. l 1~, th1~refore, the conclusion of th ls report. that the out-let nozzles will resist the imposed lo.ads under MHA conditions w1 thout rai lure.

D. Dlscusslon of Analysis Ont: of the outlet nozzles (#*2 of Reference 22) functions as a support for the reactor vessel. It is, therefore, the princ.tple concern of this calcula tior1 to insure that no gross failure of the nozzle or vessel wall will ucc.ur under MHA conditions. While the nozzle cross-section was found to experience rel-a t1vely low membrane + bend1ng stres~;es, several locationu around the nozzle opening in the vessel sh1!ll were f'ound tu

  • ex1H:~rie11ce IW'~rnbrane + bending stress abuVE:.' 1.1 s.v*

By c'-':!- ducting an E*valuaUon of Collapse Streugt.h ul' the Sl1tdJ undc:r comb11!ec1 membra11e :md b1:::11ding loads, u::ij11g lillllt 1.it."- slgr1 theory_. the fact that !'aJ.lure w.ill 1 tot 1.'C<..:ur ui;de l'.MHi'\\ loads 13 suf"ficle11lly suhsta11tjated

  • 1

~*: I I u ........ ~-

    • -*~*-

-~ *'..,....... **~*.*** ,,,,,... tJ~,,~... *:N~4zi*....t~r.......,,.._-.. ~f;..o~~~L..L.~* 4-- Yes5t:L SHEL.._::.; :.. ***;* *.*. 61::-;,/i:Jc!AL-

  • -'4L #641~~.,,,'1/C -r A'~t:>..'1/6

.5;r.E~ I /JA/LJ :S 'N're,../..51nc-c:. I I SU' .LOAD ST1r.c:n eOt.JAnw I],, A,_ Bo B,_ eu CL [1 DL.. I 0£~1~11/ F'RtSl '5.~371 P ~ t}.(;t)1K1p t-J.7 I-7,7 .;. '/.J + 7.7 22.s- + 22.J-u.s 22.s-! I . "1Fx /f...

  • F.c/f.>M-f

-s.~ - S'.:;- -s.r -S.~ -s.s- - s.S' -S:r - s:r-1 I /11 J.I A ""*Ir-; * (pF-j f -//17 t-//. 7 -11. 7 +//.J -l/17 -t-11. 7 - 11. 1 I r 11. 7 ~ I I PIPC N11/N1t/I'~ i

  • M>'/R" f<t ~

~ ~ ~ IV( f- /.O -r/.0 -1.0 1-J.tJ I LOAD.S /.-i'x/;i11/[:.,,Jl

  • t,1-iy/p..,,g/z ~

~ ~ ~ r- $.'I - 3.'/. - !J.1 i l-gl/ tl*/;i1~11.-;, J *Mc//:.,' JI-1-J./ .,. J...J -J.,/ -./../ ~ ~ ~I~ I Mxfa11t/I~ If* ~/11;/,f"f~:{ tt.,,_ ;t. 3 -gt.:5 ;..gt..3 U.~ ~-~ ~I~. I Tor-1'- J?.< 1-10.C/ -IB. :S -41*1 +44./ +/IJ.2 1-t'.S:Z l

  • 4-. +3/t, i I

~u~AJ P~c:-:s.s. 15.!~S#pc.e B.~7Jp.;-g3,z -1a3.2.J..8j.2 + gs.2 r 7.7 !.J-7.J I + 7.7 + 7.71 N.J/F,./1.."M

  • Fr. /t:ll-f t-

- s.g -5.8 _q,g - 3.8 - 3.8 -3.g -3,g l-8.JI I. M1-/A '* Mtl/F;._ * &F_y_tt. -1~.s +-/(,.~- - It,. 'i'" +- 1&.r I - 1~.s +,,,-s-I I I -Jt.-:r111t.S IQG P*F~ Al;

.~1 y_l/1
,J. ;ti ¢.!/;J t

-~ ~ ~ ~*.s- +.s - -~I -

  • S"

---~.. -*--~ LoAD5 A1r/>/;i1,,;j!.,, .~ M Yhl-t /J/-2 ~ ~ ~ f 7.0 - 7.0 - 7. 0 /- J.O i I I Al~;/,., /,I ;}jJ. lil-0,~t t1 I-' 1-1.J.S 1-15.S" - /!J.S' -/B.S' ~ ~ ~ ~I 1'.-l!-k4~i1.;.,d ~ 6tJ'}i/J.~8 t 1 1-t/. 4- -~1.+ -ti. 4-21.4- ~ ~ ~1~1 TOrAt... 77J 47. K 1d!I.O 1-tt.O +53.8 -S":J +15.? I -2(). / +f't.1 I I or r~IJ.v Pcc.s.s. 0,, -P 0 -t.S 0 -2.S" 0 -l.O 0 I -2.> I I I /V/1/A ~211rl*t , Ot:, ,Ott,

  • {)(JJ

.o~ ,()(,

o' I.o~l.tJto I Xo P1Pc

'---F~/J!Tot - *'fl I -.n.11 ./-- *'11 ~ ~I~! --....1 C~tJ Fy/1rrat ~ ~ ~I~ - 2. It. I -i /(., .,. 2./(p 1-2.1~1 TOTAL-ne -.7 -.7 +,, _,_.9 ~--=-!~J -!./ l z.2 +2.Z !

1. a;j fMAl<) =

0 x_gt_~J~~ ;_"~)~-f~~-~ ~' 7.1 +-!!.O -21.') 1--~.8I-.t10.41 +2~.1 I +. 7 .f ;2.4-! ~: (N1AJ) =.rx pi-\\f{~~)~t :rz -- l'.3D.t - JJ.5 -41., 1+4~.f - 5.3 1-13.-s-I - f'(). ~ +J~.tJ. .;.J,11;1. /:o..i181.f.f'::°tJ ST/.~:, z;t1.rE/Y~1ry {t..t1/J11),147.'J. S"t:..S 41.'I S-~-~ IS". 7 ig.~. t/.O ! 34.'/ i ~**

  • ~...

I I (P,'\\+ f'.B)AL~'1-41'~ {~~~f/~7__/_ _____ S0.2 61J.{) fl'/.' 7S".0 7f.S-74./ ! 1~-.\\ I 75": 0 i

COMBUSTION ENGINEERING, INC. ENGINtERINQ DEPARTMENT. CHATTANOOGA. TENN. c:HARGlr NO f'fM -A P.:SCRIPTION tJoncr tlozZLc..... Al llA duA<.y:,11> ~ ~ ~ ~ ~ ~ r ~ ~ oJ ~ t ~

  • S)

~ ~ ~ t ~ ~

  • ... _... *o&J.:... * * =~~~-~....

.*. *...:.:~... ~~.. -

i i I I I I I I Cur ,_ t/£~~~ S/l.£LI.. tlE/V'cJYJl. I -f- /t:JC/ll. ;l/et"/Bf~HE.S;r,e~5 (.5T.(nS..iW'TEH.r1114 157(~ LDA.D ~~e~~ f!.QcJATIC)N A" A.i.. B" B.. cl) C'- D" De. ' f't~1t1J i1.t~. ~.~np tP~ q.tW11p t-7.7 ./-- 1.1 f-7.7 I- ?./ ri-22. S" L'l'.~ I +-211.S,.1-q.~- ! Mll/J Nt/Fx//.',.,,

  • Fx/P..., 1-

-5.~ - ~-.s- - s:s- - s.s - s.s - s.s- - S:S" - S:S" i P/Pt:- 16./;41/i::}i. ~~1Jlt-~ C?S ~~ -I-/,{) I- /.0 "" /.0 "" i.o I I LO/JO.$ //,, /P1~/ R,.,2,J*1'1Jtj.fJ,.ii--- r4./ .J. 4..1 +4.1 1-4./ >< >< ><' I "/?JTAt.. a;: ,i-t.~ +&;~ - 1.1 -1*'1 ~/8,tJ -r 1S;.o 1-/J,I) 1-/6..!' I De.*.14.u rc,J~.1 1..!. ?~51/.fJ o~ i'. tJ~?l I'.,t.a:J.t 5~.z ;.ag.2 +eit,t-1.1 l-7,7 -I f.7 /- f.? . I .MllA -1/pj/~ /{'~

  • ii/!?"' t

-:J.3 ._ !J.a - 9.1 -S.8 -fi.8 - !J. f -3.8 -3.H

Jg P1Pi; Ah/Mt/l.'f..J* Mt/{!,2-jjl: >< >< >< >< 1L.5"°

~.s- -.s- --~I LOADj tl~/tilz/1.~/J

  • Mz/!.?J/it T-f!J. s-

./-1~.s- -/!J,S- -15.S- >< ><* 7lJOJl. Io 41.9* *r.l.!/J rtS:? 1-1s.1 *-r.J.4- -r4.4-I +~4. I ~:1.4.. I (">,_-...,'"'" l-\\c.-lS. -2.~ -2.~ -2.s-1 I -2.s-i " -P" o 0 0 0 0 1

  • 1"11111 *

/VlJ( I ;a irti t ,Pt .o~.. ~ .~ ,f)t, ,{)/,,. !,/), !

  • I)~

Xs P1P,:;* FL/ITrof -*11 -.71

  • "11

.n 1><F><!>' I 1Tt'6 t-TOTAL. JlJCQ -.7 -*1 +-.'} I- * 'J -J'.l -2./ I t. l. I t. c! ! 1-;; (#1'111.) ~ tr;-t roJ!t.,_ t<!;,~~)2 1-__T._'- 11~/I ->-I!. 'J +IS/} ~IS:'}.,,_/S.~ I.J-1~S.J. //..' +-lt.4-I W (AA1AJJ"' ("IA tTV)/t -)(n~T~J'"t-j'. ..,..,.~ .,. (.. 3. -1.1 - /. ' +4./ ./- "*' I '+1.~ +,.01 CoA1-e.11Jco *14_f!:1B'!_AAle S"~E~ f//Tf~s1Tt ~~ J!.'J. 5,.(, /.? /t.4." /4.e ! 20.t I 15.4- ! /8.1 ' PM/ ~I> ,'fl"* .KJ .04- .4/ . ~I I -~ ! I So-=- /.I~ ° I ,42 ! I .~ * /. I (.. r;.+) (Pio\\ t-Pe)/~ 0 (~ ~ ) /.// /. 55 /.'!!:4-J.t~ /,t,7 I /.64- /.t.1 }:~/, 5~ *.IS: S'esi GMAI~ (P..,+ P&) At.LD.V.4~US s-0.2 6().0 &1.~ 7~.D 'f.l-,s-74./ '}~.S" 1s: 0 I

0 -,_ g

  • "'. dt?ft(,.~-.a..-c>ee*

C¥1li~~~~=:i39't!SC""',;l;,*r*t.*fi¥--l!&"&e;:;:WX?.:4_~'3tr*;ar:~~~~~~~~~~-.....~:;;.:..:*~..,;._":',*:~~,:-*.~:~ ~.,. _':"' _... -0 Vf*::JSEL SUPPORTG Tl1.l::; uri;ilysl:J present.~ ih1.! :..;iructu!'al a111..i fat.lt!,uE..* t'\\':1lua-tlcJ11 or 1.he l'CH.lct.nr v~~.sel supp~)rt:.;. St1*t..~::3::3t.'::i C~)l1.3i\\lt"l'r-'d \\. '\\. LJ re thu:::c:! re.Jul tj rig 1' I'Om 1KH'J11a1 '-'Pt? ra:i t t 11 1 ~ i~': 1 d:s, *.. ~.

  • n i.; l '* *l r~H\\

scr*um,_ c:i.:1rih.1ual<e aw.1 pjpe rupture. (Sv1..' ::3lk*t*ts l\\3;H3 tlu*t1 A3G2 <:£ Appe1dlx: A. B. GeumL* lry i I --------. t:

        • - -~-----~~~--

A A C. Slgnif lc:rn t Re::;ul*t.s Stresse::; in the reactor vessel supports meet the appropriate allowables as stated in ASME Boiler and PressuI'e Vessel Code, Sectlor1 IIl and special criteria of references 16 and 18. The maximum combined prtmary stresses (bending + compression) for dE:sigr1 conditions Oi}CUI'S on Sectlori A-A of iule t. support

  1. 2.

'11hlu stress of 24. 5 ksi is less than the Section III allowable of 1-1/2 Sm = 40 ksi (see sheet A351). The bearine stress beneath the supports was found to be 955 pni during normal opera t1un. 'rhis stress ls conslllered to be :3atisfact.ory when compared to the spC'clal allowi1l>h=! beul'-

trc?S3 01' q50 p~.t l>i' reference 16.

Pft:::Gf A-ZCJ' ~.*

f~ I l \\ .ff ii H r

1 1*
  • j I*

. ~ ~ 1:

i
1 i'. ii

. 1, h .1: ~ it f* ~ !" 1-;q4 C: A- -.30

n C. !3lgn lfi ca11t.. Result::;

(CL'llt 'd) From the standpoint. of.rutlgue, th~* ~uppl'I'ts w.ill wi th:::t.a~!...i n mlnlmum of 25000 cycles oi' hentup a11d cotild\\'"" (~100 rt~ quj red); 6000 cycles of dt::::>lr;11 selsmlc* (l_QQQ_~~qJJi..l'~~d) <_1*1li aao* occurrences of accldent (1 required)° (se~ dht!et. A356). The maximum combined primary stresses.for acc:l.dent c~...,ndJ t, tun* also occurs 011 Sectlott A-A of inlet ::;upport. #2. This st.rt:>SG of 50 ksi is below the nllc)wable of 60. 7 k~l of referetwe 16 (nee sheet A353)

  • The* m;ucimum shear stres:J occurs Oil Sectio11 A-/\\ of inlet sup-por*t #2 during accldent condi t:J ons.

Ss = 14. 8 ksi which is .wc,-11 below the allqwable stress of 30 ksi (see sheet A353). D. DJ3c~ssion of Analysis The Consumers 1 re~rctor vessel has three supports. These oupports are inter:ral with three of the main coolant nozzles, ( 01Je outlet nozzlE* ond 2 inlet nozzles located 120° opart). As referred" to ln this report, support #1 is be11eath an out-let r1ozzle and supports #2 and #3 are beneath inlet nozzles. / For the case of frictional loads ac.ting between the supports and the matching foundation, a frictjon factor of 0.5 is used with normal operating support reactions. Due to the fact th:i f* the supports are keyed, frictional forces ar~ uot con-s.! di:-red to result from seismic, control rod scram and pipe rupture loads. 5.150 VESSEL SHELL AND BOTTOM HEAD (PART I) A. Abstract* 'I 1his ::malysis presents the structural eval ua t1oi1 of the ves-s~l nnd bottom he~d for the design pressure condi t1on. ( SF:t;.:>hf?e t.s A363 thru A374 or Appendix A for detailed analy-sh;.) t I ! i. I I j I \\ I _.._.,_,__...N_-0~:------~------------_,.--_,...._.. __ .,._~_..--_..._.,!l!!""".,__.,.._,..,...._,~µ.-..<._G_..., ___ .,_.,.-$-iA--l.4~*-.-.. A.----

r;:a,.J"2 POVJER ~l...::J SYSTEMS COMBUSTION ENGINEERING. INC. B-1 Page Number .APPENDIX B Sc!SNIC Rc/1/1//Jl YSJS OF 7?-le-Co/1/sllHERS ?oN£R 0-reAJvl GENG",e,1-roR PRJH/l/2/ sr,eucruR!F SUPPOR. T LUCS. B-C. B-2 E-3 B-8 B-10 B-13 8-/5

~~pQuJicR

  • H
11. ~ *

~~ SYSTEMS

  • ~ON EN<l'NEER,NQ 'NC B.. Page Number
5 I c.*,,q 11\\//

G/VC.f2',1TOR 1'1£Th'OD OF,4/o/"9LYS/S :

RoN 71!c-CoH//o/l/EN/

Srfi'ES:S ~):t;.M?r" c~-1Jzo ~£ /lRc-~:s Or-S/c:>/f1;:./c~N/ S!REss /}RE /o~,AJnF1W, * /1{=N SG/S/"J/C. *~Mos r?R~ *(/.se:o 70 Kcco1vp0rt;- /#c S/G/l//FIC/.JNT".srRe-ssc-s ;C/NO /Ht:.sc- /7R~ 7Jle-/\\J ~oMPl1RD /0 lh'c (),R/C/d/4~ /9L.UJNt18t.c.STRSScS.

  • M6' /?/U' /=b~,e Zo~-4//0/IJS /9/VAt.7.?E'D: 777.c ~J~/112r ltVt..'ET N~22t~ /HE P/?/~r?;ey OOTLe-T do2fl.-e) ~~

?R//'14RY. SIRVcrtJ!f (/:e, SUPPO/C/ S~!IC7:) /9/YO /?/~ t.JP?c/.f 5(.)PPO!Zr LV4S, roR 7/7G9 //VGe//7/VO OVT~T /YOZZLE.S AND T/1£.P,K'//'-'/IJ/:.Y S/,et)cTVRc).C0/'1PLt:T£t.,r Al"£w S1SHI(! L.0'401/\\J<SS #/9rt= BEEN 0£v'cLOP£"D.. /#Ese-L0"10//1J<:::s h/cJ?i£ CeN/<~rcD BY 4r7Pt.Y//llc;" 71/£' /V'h/

Sel.S/'11C '4tClRl1 /IONS /o /9 CoNPt.ET~

/</:J<17t'I? C'OOVJiVT c5Y..5Tt:H ~t>HPVICR NtJDcl UT/t./ZIN<::; /h'~ N~C:-ZI ?/P/IVq FLeX/8/i.I/~ /-JrY/9t.>Sl.S P,i:?Oc;,e,tl;'f. -rt;~ Mc VPPER SvPP~r L CJqs 7H"c 0<<14'/N.4C-s~/s,.o/1c t.~~os ~//C 8c-c/'/ //\\IC'REA~ED,8y 77lc R-4770 OF 77;6 //£r1 SE1S/'11C Aecct.eRl711t:J/\\/s 'TIJ THE 0RKi/N4l. ;C/<!~Ct££/JllONS. Fo/? 7'#'c //Y~E/ A'N.o CJv/L.e/ 40ZZL.e:5 77;'~ SE/S*HIC!. SrREssc:s /j.eE Co111B1Neo Mrr1 V/c-APc,/?()PTtJRE SrRc.ss~s. h>R '71-!e ?.R1l'f~/2 l"'

  • 5-rRvc TCJRC 1"'9No /'#e-VPPcR SoPP01c-r Loos 7#E Se.1sH1~ SrRES.s£"s,/}/?£ C10/1Js10GReD ~LaNe

. Su11111Ae Y OF KEsui rs : Fote At.L i.oc,,,c; T/O/IJS 7H.c ffe"N S1GN1F/<7A/\\// Sr.eEssc:s A~?e Sll"wAJ 70 Sc-L.:SS 7#"'9N 771£ OR1G/N"9L /lt.~Wr1BLCS.

r;~POVJER k.J~L:::J SYSTEMS COMBUSTION ENGINEERING. INC PK'_1M1-lil.1 tJ()nEr t;fpzz1.£ r.eo/f./ SUH.Vff/f(i OF" Sl6A)1nc/J;J/ RE5UlTS _. @S/JFE &10 B-3 Page Number IR0111 &r1rr. *s-rzc-ss ~£ro12r: P.e1/1ARr #EHBE-;t.vE' DuE 70 Jvbm,,c;L (1?.EI=", a 8-/5) C>PERl?T!N<; + 2 (0516"/\\J S~Sl-tts) -f-P1Pc RUP/tJ/?C'== '1~9.S ~ =~~57/ /N'- ;KIP.5 /'1'2: -:::ts;976 //\\/- J<; P.:S CONv'.K1/1tJ~ /'/?a1'-I x-Y-E Gt.OB/JI ~OOW/"1./Arc= ;sy.:src11 ro Tr/~ .srREs.s R£A::;Rr /-2. C~.Rl///Y'"9Tc* srsre:H- (p,qc;E c-::s1j !='-::: (F;.,i.~) ~~,2~507'- 7 ~~5a l{ = (p; +- ~)~2~50 -5 ~ .,5° i{ :: - ( ~ - t:;.) ~~ ~Sr> /-1 1= (~ -f'1x)ffin~5o* ~ I ::. (~ y. ~),.a0,2.-('_5"~ ~ 41.;.,.f"_?" D /1,- =- 0 ~l1z)~1n 2 ..(',;;'ti 7'-~.4+1-)_,,;" ('J B-19) I I I

~~'"!1~ POWER ~~SYSTEMS COMBUSTION ENGINEERING. INC B-4 Page Number PR11-i*,')2r CurLET /VcGzZLr -F-=- +/-./63 l</PS ~I::::+/- 20/~ /H-~/rZS 'JI/ = /Oc /C/J=>S ~' ::: ~S76,1...V-...e/Ps Vz -=- ::t. /7 ~/~ /Yr-= 9927 /,Y-.e/~ FE-01--1 SvKe-ss S;:o,<?7: (P1tc;;£ c-sz3 I c-sz--1) .* (fjs 8-2/ f B-22) ~= Z -- %=* 3/8.7 h-2 2~88.58~ 3 .,,e:--/ ,I;" < / .:,,,.J / ....... ~ N' i =.75,<:s/ 17;' ~ = /.8,<:;; ""7 J( - j~z.;y;~ A - A -:.,32KS/ ~ z~ :: /-fl -<s/ J~/ /(Y'\\Z j~'\\z 1 v,:;,,,..::; /;~/,.I ,-~/ + (., ~/ "' 2,.s-.KS/ ~ _ ii J 117L"_ / /.l- /Ze : ~- 2 KS/ . * ~.ev~-9~ 0Pc:-.,er17?,,vc; c (oc.s1~,v SE1s111Cj 7'- f?.P.c /b?Tth{ (Pl1G£C-S2!,) ti;":=: /./7 ~ 2(2.-:) r 23,7 = ,29.87 ~S/ ('CJ 8-23) .'r ::::- . 04 -I c{2. i.) &,8 2 = //,, Z(t:,..<"S/

~~** POVJER

  • t -

SY"T-P.45 i.;..,;;J .;:, I £:.Iv I C'-OMBUSTION ENGINEERING. INC B-~ Page Number Aoo111.1c; /?e'EssvR 5Tr2cs.ses.' ( P11ct: c -531) (Pt:t 13-Zf) V:X = Zf.87 7'"5,8S= 35:72KS/ 'J V& = e.o 151 v;. = -/, 2.S- ~.S/ ?--- ::-././ ?/. )'-"0::.11 r ,,.~cg

~"'.'~§POV/ER .. *l-SYSTCE&-"S

* "fill

&::.I.ii COMBUSTION ENGINEERING. INC

  1. 1,-1-1?.r 00'LEZ- /Vbzzt.C NOZ.Z.t.6'" - rk/lo..)UNCl/O/\\/

B-~ Page Number FROM SiKS.S ~r=Poter: ~Cf1~, .. rr LoAD '= (!urlrttJRY,,,~.:5JC!V1F1CA!V7' ?~N-1,.e,Y. Lo0t.

  • Ht:HC?-1Nt: CJoe:- ro R"..SOL r.s ~. 2 7)

DESIGttJ Pl?E"sso e~ :SftF' S/JWZ:OrJN (?1 8-11:// .:SIEJ:SHIC 19/'/D P1P~,R{)P7()£,: \\) A~111AtStF = /_/ 7 =..,.S:S-A.S/ r= /~3 K/PS (PAcG" c-52.b) <13 8-24) ~ = 11, '-1-L. ~ = (201~ /lll-1~1.Ps) f(/59/~0c ..t'/-~ = .3b.381~-K1r-:; rlz = ~I +~ 12 = (~761"1... /.1"1":) 1' (/f.r.itv' )(/7.<;'~ :"3/-/6/l"l*KIP_s I /J"°?/~ 2 rr--~z.. = ~30Z /n--pP_s FR~.., d.1.,m4p,o.-'9#&r-;1.s (P~<:E C-52~ ( IJ B-zs) v;* = F>( /. /¢'?tj ~ /t"/~- OS7CJ'1 -:::.-7.35 VB :: p:~ 2.. ~:Z/ -I-/'fx... /2.,,,,,-9 = ;{Z/7

  • ~R#r?t 0PePAlliVG + z {pEs1~1"/ sc1.s111c) -r P1P~ K/.Jp;-()1ec (PAC~ C-5zr) <FJ 8-2~)

~ -= /, 2/ r /.-t'7:r.S:.53' = 8.. 2 I ~ = ;;,a4r-z.~.Y..'f"'+7'9o== /2./7

~POWER Jml-5 SYSTEMS. C0"48USTION ENGlNEERING. INC (P~GG c-s-r1) (fj B-28}. B-7 Page Number v; =..3.8 7-8.21 = /2, 0/ D& ': 27.97'-/Z/7= ~CJ.o7 Yr = ~./;ZS-. 71/c :5Tl!'Ess //Vrc1V..S1ry.Ts 7#e-/\\I :

[1*~POV/ER l~L.S SYSTEMS COMBUSTION ENGINEERING. INC ,8-8* Page Number Fi<ort

SUH11,!JR'1" OF 51~/i//,C-l{'AN/ Re-SU(. r.s :

(Rt:P-. ~ 2~ @ SA.re cAlt>. ( FJ 6 -29) rJe/rt'9t r /1e/o18RA;Vc LJVe /o A0-e>11'4L 0PERAT/Alt::; -f-2 (ueS/GN SE1sH1C'~ -I-AP RvPruRe-

== cs;.s KS/ < /./S'1 / ': ¢5.5 ~/ J . ~ :- ~ ~~ K/.PS Fj :: +/- /t;, 7 K/P.5 f; ~ +/- 5"6 KIPS ~::-I-...;?. 8S'1-></c;..S /N-~IPS ~

+/-...;(090 >'/OS /N-K/Rs

-3 /12 :. t:. 5..3.l"fl' JI( /0 //V._ACh~S ~tJNY/Z71N9 rRoH r#E" x-Y-r cooeo1/\\/.1Te S'/'ST~~ 70 Th"E /- Z CO O~O//IJ/.J7G.S Y~rt!:-/'-1 01=" T#E.

  • STRESS KC:FO!CI:

(Pn65 C- -?'7Z'f-47z~ ~-= -r=; ~ .ss° -r ~ ~35° (fj~ 8-32 ~13-33)./ v; ::: -Fx ~SSC - *F: CJqQ.35 0 J Vz =~ I rt ::: -1'1: I ~ = -~~.35°-~ ~35() Hr = - ~ eoa 3.s-,,_ ~* 4?..3s 0

r;::a~ POWER kL~SYSTEMS COMBUSTION ENGINEERING. INC

-= +/- 357 K/1$

V;::: i-387 K/.PS ~ :: +/- 58 K/P..5

2.

Hr = :t: 5:5~7><1d /N'-K/..-'O' /72 a~ /fi/.c Sr..ec~ s Kb /?:;/e/ : F 7 +/- 707(~ ~1P.S ~ =.~ 737,..r k/,&s" Vi "=

& -?""°./,</PS J1' =
t /,OJ</0_,, //J/-K/?S

~I: +/-6.55~/0 3 /d-K/,OS .l1'r -= ~;; 6 z x/o3 //V -/c/PS 8-9 Page Number (R£F. :5 c- ~73) (~ 8-33) S/rJc:~ 7#.t MN L'o~os A~~ EYE.?YNf-lc~~ L.:-ss 7#""9..-v ?#E-0LD LOADS

,_. \\ ~POVJER ~~i_c:J SYSTEMS COME;USTION ENGINEERING. INC B-/O Page Number .P/f'l~/lR_L 5/Rlk'.'.7/?IRC° E~{/-47/0"1 Pel'? S7J2CSS,ecrorer ( R15E c-171!!) (Fj 8-35) (P~t.- C-/76) Ai-Jv Se/SFY1e 4/~os ffCJH /'YEc ~rr-?L)".5/..S (~ B-37) VFORC~ -/../O,-f/ct?f\\/7/tL : ~ 565 ></OG/~s ~e rf2n('4t... = '2. 2Bc.1</06 /6.s ho~~evT-4£t:)C1/ ~R/~.

  1. x/.s

= 2. 8S5>l/IJ6 Pr-/6s ~ 1101-te-rYr-48a)'r YcR;; ':;;.O '4-x/~ ¥ Pc,<; sr,c>.rss,fr?o-<r {(rtc:: ~ <:'..'-..?.?.) ( FJ B-34) S/.5,.-:,11c s1RE.."S5/!fs (co/YB/,ve.#R/e I *..e~ -/ s 2r- -f's~ z 7 = J ( S75-r.3.~) 2 -r ¢(/,~z)z. 1 -=

, 17 <SI?? ~ 26,7 ~I

It:.

  • i; r~§* PO'MER

~ SYSTEMS COMBUSTION ENGINEERING. INC B-// Page Number PR1;.-/111?' Sr:eucru,.<c (CottJrb) STRC- ;..:,.f VFi tWiT/1)1\\) ( P"!CE c-I 7<'/) <3 8 -.{/) S£'1StVIC +- C--9~.1 (so= _,;'5.s) ~ =.s:75-r- ?.5~ -::: /s..s / ( CALCULt9rcD_ S7K'.=.s-:) 5; I :: f5c,z - -7' s/ 1.,, / (:::.s:sJ- ~(/....-i/ ~ -:9"5. "71' > ~ @ ~~~ ~

3. 0 7'-27.5Z :::..3/./~

~) ;1/ : ~ 5; CdJ (9o -P-t)-= -ff ~s:~iJu(90 7:,31 1 = ~/, ~ ~/~~ '/ 0 J > D 'b~ (M:>rc-I //'/C't.UL:iG.5 p!Pc£ RVr'T.V/C'E ?- S6/SH1c LO,;t!/D~' 5E1::;;111c + c ;t:;sE 2 r; CO/'l.:5J0R/NC SE1S1'11C 0Nc_y: Pm':.S:75 s6 /--?'2 S 0 -=f &'5.5) 2 - -t'(/.-1"2)" 7

45:"~.> ~ @D

r~ §POWER ~:.';I SYSTEMS COMBUSTION ENGINEERING. INC. B-12 Page Number ?/O'/Y"9Rr SrRucrvRE' (CoNT i;>) 0ct= C-179) { 'J B--12) S~/5/-1/C r C.45~ 28 ~ = 5.75" S..s = /.42 ~/.3.76 = /5:/8 ~ -::~ (~.S:s)z - 4?5."/8)z.' -;-- 33. 9 > ~ @ ~ = 3.6 7'-/5.~8 = /1.tJB ~)al/or/= #(33.9)~(c7o :::.[)-= #.G >fl, @)

f(~POV 11ER 6:.:'i'!3L5 SYSTEr11s COMBUSTION ENGINEERING. INC B-/3 Page Number 5VP?ORT L vc;s S.G, SNV813E!< ~c:s£ L':-Aas /Yf.,ec H/< MR/Zodrr'?c.. 4,,..,,,0 X-.e:r/cr;~~ ~t:'Ea-,e,-IT/t:WS OF.3-le::JA/YD * /33) .ee:sPeCPv't:.t.r t/s/l'lej /r£,e/c0t1/7~t 4h,.-o ~RP~~ ""9cf"'Et"R"'1T,O.V5 O,t::""

  • 91 Ade:>
  • 41) J?c.sPc<'TIVEt/._, r:Et.D..S &c- ~ct~/l//dc; Lo.""Jo:;':

.S.6.,<E7 M>1'</?. Hrzct: =- r 31 z x /O" J6:;i Pc~ J::'E7;' Me- /9tY~t.ys1s Mt.t.. 61'.lsioc,e

r,
:/c-.sE Se-1sH1c L090$ 4LON'

~~POvVER

,..~SYSTEMS COMSUST!ON ENGINEERING. INC B-/4 Page Number 5UPPORT !.. t.J6 S

( Rc-F. ;::1 4.s:) S1G/V/F1~~Nr l?csvL r-s. * ( f?7 'd-43) 5H~-~1(.T£/-)R. OU r 4 r ALL PIN.:ro1,,v TS (REF ~ C-773) V(~B-~ I"=? ~ = ~~-=- /$ /<.S/ <. 6SN) =./";A<.:S/..J KEY L uc;J OLJ/S/Oc 6cJRFACC-OF SHE'LL (flEF. ~77!(772)

  • ('3 B--if7f1J-5d)

.. t1c. '=: ;:; e = (..3'/z. t:1Psj(91rv) = 2808 N -KIPS ~ ~ 9~5' lie.., _C . R"t: C TN¢.

= Z:. 3 8 Ft..u10 Fkess =- UNCH;JN5D : 2 3. 5Cf 70r""9L ~ sr~e-s~ = S/. 87

~ + ~ =-.3/. 87 KS I < /, 5 Sh...,,CJ,/,/:S/.


..:.c..

C t l 1¥C4i_ .. J Ji AA A .. ;.oo. fCR>>x;:s 4!'Ai M4 t..ea

a sc;s

26 I. P/-J-6 G-IS-21 ;< 5.3.2 Prir.1.:iry OutlC't Nozzle Ahf.ltrn.'.t TI1c pt*ir:*,.1ry* outlet nozzle was an.'.11/~!cd [or pci:*r.~~J.!."c* and th~~mnl effects by cilc Seal-Shell 2 c~mpu:c~ pro:;raq. Pipi:! loads were analyzccl by cla:;si.l!al beam theory and nijlaarc.J analysis. It W<!S fouw~ that the s true tu re mcc ts a 11 rcquircr.:ents for the spccifi*d loading couclitions * . Safe End Primary me~brane due to normal operating + desi~n seisrJic = 15. 39 !{SI < Sm = 26. 7 -1{$! Primary membrane dt1e to normal operatin~ -:. design seismic *'*pipe rupture = 39.6 KSI

  • * < Sy = 41.4 KSI Primary wembrane due to norm.al operatin~ + 2 (design seismic) +pipe rupture = 44.9 KSI

< 1.1 Sy c 45.5 l<SI

  • Prinary + Secondary stress intensity range =

59.0 KSI < 3 Sm Q 80.1 KSI Nozzle-Hec!ld Junction Prir.1ary membrane= :?4.1 KSI <Sm"" 26.7 KSI Pri-mary local membrane = 33.3 l{SI < 1.5 Sm = 40.0 KSI Primary + Secondary stress intensity ran~e = 68.35KSI < 3 Sm *.80.l l<SI Fatig;.ic - ac;:Jequa::e by comparison with inle:: nozzl~. Ace idcnt - Primary lo ca 1 rnl!mbranc."' dl:e to ucs i:":n pressure, sa fc shui:-do~>>n seizmic, & p i.i")C i*up curl! - allow.:ihlc: is l.l Sv. ! ~ .. -..-. -.,....,....,~7""'(,,._~~...... ~...-:Jl~....... ~-.-i:..._...,,!"C~ >CJpaq:A.P'<I",.,....... i\\'C)f... ~'""?"~~..,.._'ii.4fW.'P.~*~W,..._~~~C'"'~*..,..~..___. . z;c; ________________

' J I J l I

  • 1 ~

'(, 11 lJi..sc:ussi..on ll1e nozzle was ana ly~ed for pressure e ff cc i:s with the Scal*Slacll 2 computer program (R.:-f. lt).

  • li1~

condition use<l was design pressure (250;) PSI) wich isothcrQal t~mperaturcs. TI1e thermal stresses were ignored in this analysis sir.cc they have no eff cct on. the primary s ti*l!~;~es. Si.nee it: coulu be se<.*n from the primary inl(!t no:!zlc.: Lhet t the* primary + secondary stresses arc \\*h.> 11 b'"' lO\\~ the~ allowable wi.th tlwrmal stresses included, it: will be.* ass1.1mcc.I that the s~me holds tru~ for the primary 01ttlet: no:~?.le. l'ipc load stresses for both outlet 11ozzlcs were cal..:-ula.tcd at the noz~:lc-head junction by a !H.j laarc.1 analysis. At the sure end, the stresses ior N.:>zzle 'n were calculated usine classical beam theory and Nozzle

    • , ' by the plastic hinge method *

. Primary membrane stresses were obtained by combining mfdsurface design condition stresses and maximum pipe load stresses. The stresses obtained were fc1und to be l~ss than Section III allowables. Local membrane stress~s were obtained by combining . mcxi.mum midsurface design conditio11 stresses and maximum p~.pc load stre~;ses at the nozzle-head junction. The s :rC!ss~s obtained were found to be less than Section III allowal>les

  • Pri.mary and s.econdary stresses were calculated at the safe end and at the nozzle-head junction. n,e strc>sses obtain~d were well below the 3 Sm range, so the conserva-ti~c method of combining peak stresses with maximum pipe load stresses was used.

Ft'om the primary inlet nozzle analysis it u.as seen that fatigue will not be a problem in the primary outlet nozzle. 'nlat fatigue analysis took into account the largest stress from either the inlet or outlet nozzles and thus.applies to both. i

  • j

~ J I ~. i i l \\ ' i l ~ f I I I,

_l 1..

-cimum n III
ie sses
.serva-pipe
utlet

.les i i 29 P/-JGG"' 8-17 n1c decay of nozzle stresses in the head was found by. ploL:tini; strc.:ss (from Scal-~"hcll) vs. dlsL.:mc1: for f>!"L'G:>urc, and by using BijlanrJ <l.:i::a fol.* the pi.pi..' loads. The :;cc t *Lon III al lowc'.lb les are used e.;<t:upt for:

1)

No::mnl operating + design Sf..'isrnic + pipe ru*.a.urc loads - allm;able is yield s_ixi:.*s~.

2)

Nor111c'.ll operating + 2 (Design seis1;1ic!) + p*I.pc* rup~ur~ loads - allowable is 1.1 yicl~ str~ss. (

1 1 , I ~* I COMBUSTION ENGINEERING, INC. ~GINE!tRINQ DEPARTMICNT. CHATTANOO<IA. r'.NN

  • CHARO!I NO 2~(pfo. B T'"'E. 'f>,p-z. L,,,..t:>s G,vft"'-

CE 1-ow Aw t::> 0 f'1 ?JioJ~E. Art..~ tp..o.-,. 5P~c..'"'C..b't*oN No 7 0 P - OO"t. * \\ ~'4:. ?,?te K\\Jv\\u<'.t'l Lo~'b ~ AR~.\\ 0 '3\\t AT'P\\. \\,.0 ~ r; PII R. AT~ \\i..'( * 'I ~ 01.1T\\.t. T /,,. r.l ,.. *,..,*I --- l;J '~* / ~.....

  • -+---

-+- ____... ____ _ 0uT~£T CON~. t\\o~"",.. ~ Oi' TIOM t)'-\\IC!t"°' so.o -175. 0

! \\0,0 p,p~

(*) ft) Rv" ~.e. -\\~l!>o.~-- ~-!..I7o. o -.3 ~ C.Oo, O l"') t*~~o.o ~*.... .~~ OwT'i..t~

  • ,_._... ~

. ~/ -t~oo.o

-~::,,.~;i;llD--------------------------- *-**.. **-* - I PrN5E B.-19

  • r....

COMBUSTION ENGINEERING, INC. NUMllltl' C - s;- Ir'/. ~ I ~ Of' . fg_. \\ CHARQ&l NO "2. '? l., G,. ~ DAT9'--i2:::;;.....;/;....._/ <<.l_../.___<o~'-llY A ~ w 1 *** ICNQINEE.RING DEPARTMENT, CHATTANOOCJA, TltNN 9HIEil:T ~. l'TIOH C

  • 7.?.

p~,~P.."1' OvT\\N.,.. "Ne

  • _r£... aucK CAT*&....o----* *Y--

lt-1. P\\t'E Lo"'~S 0"4 \\~,i... °FP-e.\\J\\O\\J$ ~A~ 5 A'P',~. x*~ A"tJ,. x- '(- ~ c~1'.0\\'N)l."T~ S°'\\'STF-M A..... o A"f:,'1;_ Co""v~l".."\\E\\:::> To T~~ \\-2. Co1!3"-~°'"°-rl£ c:,....,..,..~h o~ R~tr a.o ~"( 1\\.. t, Fo~'-0~\\W~ E~u~-r*o-5:. t -.a ( F~ ~ F'.,:) ~, ~ "t 4--:, -+ "f-c s,~ ~~ \\), = l F x + FE) 5, ""' t. ~ 5 F '( s \\ ~ ~.s

  • vz.. =. - ('F1... fx) s '°"\\ +.s

}'-1, * =: (""" '!:. - ~JC J '5 ' "'-\\ + 5 Mt.. = ( )-'\\;< *+ M~:) $ I Mt. ts "'1 y s IN + 5 M-r ~ ( M ~. t "" ? J s I \\J?. + 5 + M1. S> I l--l ""r 5 F iJ-----+-".......... '--~ ~ - ?as. ..\\0?..'=* ~ \\2. 5\\. (. -\\~i:,\\.C. -~---- -*.. *--*** *--- G,75. G,~5. - °Js+. Ga - '!>.!..;<\\a"" "'3, G, ~ )'.. I o+ 3.~8 )(IO~ -5.2. :>c ro+ S.'a. )(10~ !i.?,. ~\\I.It 3.(.S,KIO..... )*'!~lo+

-f \\..UM~U::> I IUI~ l:..l'fvll"'H::.;;;.K114..:: ll't"'"'* --* ENGINl!:ltRINO CEPARThUt.-.CT, CHATI"AN :¢ A. TltNN, CHAftO 11 HO Dll:!ZCRIF'TION C.7, i. r)',\\r,?\\r, ~ C>vJ\\,.1:-,.. ~o-a a.1... t: C..7. 2. ~ p,_!_t; ____ b.9~_'b") ( o,.. ~<<:.... i:.) ("'oLi"I.~ 13:) * * \\'1E P1P~ Lt>t\\tl~ Aciu"'G l>~. T,~ l'i. 6->TS*P5. SuRF1't..~ OF TtiE ~e:.P..t) W,~'- "lo1.1 ~, Co'"'-<""',.('.".). . f9'°" u~~ I"' r'""'E. fh:Aer.~.:t:> L ! /~~~~*~- L: '1. ? - 8 ~. O * \\ S, 00) ~\\ M~* Y'\\T (!"'* ~' p,.') (!w *'f'..1P"";J (Tw.* '\\<.*<-'~ ~

  • -S. \\4' '7 X,,+ S. \\~1 ~lo-\\- *.....

5,,41t7 I(,,~ 3.C."T'SAre'r "!I. ~'15 lC1*,. ;~ .;. t' k.: -~~--~~--~~------------------------~---~--------...;_ _____ ~__,! (

.,..---------*r.sin..,a;a~ :

  • ocru:w=-.. =rmzne::ITJX~

"'.'",:~~-rl:it:!A-_,_,.,._...._Mrt'%'te.tta.gp~--~*i~~~~~-I'. P/-14c-B -21 ~'k.1 COMBUSTJCN ENGINEERING. INC. ENGINEERING C£19ARTMltNT, CHATTANOOGA, Tll:liN CHA.ROI: NO '2. C)~ C,.. '°3 PT'ION C * "'?. Z 'PP IM"" NUM81:R C - f;' e !L V GHll!:rT 'Z. 0 O" 'f Q - /" . DA n 5 J 1 "r / £:> '"i 1\\ r:- LJ CH ECK DAT DY--- C.7. ?. "') p,~~.Ll)~~ CST 1-C. ;- $ ~.;- ~-.

1.

i *R-r.. ts.e,, -~ Pio ~ l ~

  • 2 r;

~~F"CC l;: ~o --~*------ Noi!'1!!1..rr_ P.n. :- /? (~r -i Ro) .: * 7~1- F A ' "'" ( v. D? - R/) ~ ~ I ~ * ~ I....... 'A' ~ *? =- ZM *(Ro 1 - R:r ~) ~ ~t:.<9z, sa I""" ~ j.* f'. H ~ r"" = ~ rt -=* /1z !". li= ~ h ... }-1x? M ~ ~~"'"i(ri{)t. v ~ Jr,J'0 + rv~).,_ i---------....... ---*--.. -. J I Cl) """' )) ?"""' Pe, '~ __ _,__ ------4*---*--* ---- .~~* "3. '? 1~o l\\M A\\. j O~!!!f A,_,_ i "D~s tt:. ~ ------ .~ ~ Ll.:....5~- -~~~z..

3.'

\\,7 .DS "?.?..S . I I ~.OJ+ I I

    • -* **.,_ I 3..,?,_ __ 1.

j~t--l ~ ---* -* __ s _ _J. ___ _ .. -**-*+"Z.~.:. ~** ~* > ~.!..~}.___ ~.t G. _l_~-~., I I..§!..8.~-1 . 1,;\\.1 ~ . 4,.*, )~l i ... '-~ l ~ts~ !*::.~; ' r~ " ~~n*~; . ?.. ~- 1 tl _: ~ ':}~*.

  • J~f..
,.. i
l Al :.

~1 :':.' 4~:,;:*i . i]il~ 1 *~ ",,.::i ~ ~;-* ~.,~., i: '*: *l"' t ' f * . -~~~; *.:.~ "'.f'f:t: ~'!~~~~- .... " "'i' 1~3

  • ~***
  • ~*"~t*;*

~:,_: ....... ~-~. ditF'~!' %.. ~~ i.

~~'\\*1
  • '.

. ** r\\I..* "" '1~(~ ,; ~J: -~*J]:.* ..... *~* !i;-. . ~.. ". --~)l'f).. .

  • 6,,

.,.., t~"' ..... 'i~'

      • r.;°?...

.rit.~.. -~; *l

    • *1* ~-
  • .~~:

~~~

.~r

~<;;' . '*f'l.l . \\*ii** .. *.~~~~/

~.
  • '.~*

N~- ~

~f~

.. ~~; ~., .~'": ~~

~f~

~*I,*'

  • _j,
    • j~

.Ii ** -l* l.

  • ~

~~-. .. ll1,:* 'l -,~:F* \\

    • 8{

i . ~ '**~*... \\. {

    • ~f:.;'*
  • 1~1;1 ~*

... :--.r .. ~1*~i'...,. ' ;*

    • Jnt:*1::

'.~if{ ' .. 'i~t

  • ~\\'.k

~~- "~ 1*~ .. \\.;,i

COMBUSTION ENG!NEERrt.zd. INC. ENGIN~ERING CZ:?ARTM!t~T, C:iATTM8"1A. Tiucff. CHAROC NO 2 :)~(g- 'e 5 85 z -

J p;:;c;~ B-23 . r-~~~ x COMBUSTJON ENGINEERING, INC. NUM11urR ICNGrNl!:l:RINQ DEPARTMENT. CHATrANOOQA. TICNH. elHll:ltT '2. '2.. opr "l6 CHA"oc No 2 ~ C.C - G OATl!I' 5.J 1 -t.f b-, BY A e i,,,J PTIOH C."7.2.., ?rt.,,..."~Y OvTLGr Np?'.,,~foHIECKC.t.T BY--- C.7.2..+ 0'<' *- ?-= \\. \\ 7 .at ~.7 5 z..c:; 1 \\ *. t7 + ~.ss + e'3.I = 27.1-5 .* 01 ; 2.S? + '* S"2.. ~,.* 7'3 tf; - I.\\ 7 ?- :- .o4 l ¥. -t 5, I '1 -\\- 'I" 5. 7.i;..\\-

  • ~* c.=*==

";g:c

esswc I 1 *. 2
r.

j ' j I.* ,* I j f 1 J !.f '*I i-*;

  • § "J

~-~ ~, ~ l:: j} -~.. ~*-,,..

.t 11 j"

. t.1 ~t ' I - t -n ~ ~ 1~- ~ l 'ti ~ ~

t. *i

~ ~

~

~t

  • r u tr
  • t :,

~: l* ~i.,, 'r ~t.,..... 'L

  • .~
(

.f .... J COIYl8USTION ENGINEER N<p. INC. 7'-EHGINEICAINO CltPAaTMl!tNT, CHATT, :K:j.>cA. "TitNH. CHAltOS HO z °> (.; I //I...* = D --.::... /' / ~,.,,. NUM.,ltA C>flrli'T Z, ~ OP 4* i; &)ATV ~/11/,,':2 l!IY ACtJ*-* DEBCRIM'JOH C *Z Z p" M "'?'..'<'

  • OuT'-1!.I ~OZ.flU:"

CHECK DAT*

  • -*Y-.

i):!;:;.c. .,I I (;, "; ('.. 7. 2. ~ ? \\ p I'!. L C> ~ "O ST ~ t:. s ~ ~ ~ ~o ~~l--~- \\-\\ E.A_~ __ J~~~-~ To T\\4e. s,MPL1F"'(' Tt-4E.. A""""'-YSI~ T"4E. LoAt>' U~e.o :r~ \\3,:rA.~f'-'O Ak,..\\..'1~'~ s'"'~""... ~e. T'"'ti.. M~x\\'""..,""" f P ~"'"\\ 'E. '"'i '-' '(; n.. ~ Oit, 2 I-~* v = J[Vj-t -+ ( VL)i.. M ~ J (M,').,_ Jc ( M~r ~ * ..i J.-*

  • ~

-~ M l:':::-:-:::---r---::-~,.--------r--~---~~~----+-~-~*


1,f~.

f.
c. ow.o, I F "

Vr. 1 M I _I M I. I M T (\\(, "~) ~: ~~*~(.f~K,.,;j(':r"1-~*'""\\ !('1tqp5. Na......,~ I I '-'l"EllkTI o'-l I I 0 5. 1+a. z'.+ I ;<os+. J ~,~e.+. I sl!l~7. 1 1.~+.c. 1 *~... ?'t.. t)r:_ S I~ lla <<;t,Sl"'I u:. ---*-~ ~:. 2.. \\ I 31 s. I 4-G. s.1 I..!§. I 0 ~ J ',s 57' cO '" ') 14. _j-2._r..S._U!_.I t'.'~,. p,,~(1) R11,,U!\\'E. 72 5. I.?i. ~.. j~* _ l 0 ~ 5., l.l.S 1(1*. '*' '"~' I It '5 ~ ?,~(z) llu"'TU !'. '- f'1PC ( °!J) R"Piul'(' ,,,,~ (.... ) R\\ltTI) -I!. l z 5'. I _!_ts z.

2. x '!+

L. __ __l 1~~ ?-. I c;:.~!!.4 G.75.I G.7s. I '5i.l. h.1x10~ 1.1Sx1*~l?~*~~J.~ ~-1.. xn't '3.? x11f f 3.?.._,. ~ J f,.'\\~ X**'* I-*- I J j_~"' .... ~ G *r,. I f' 1:, ?.,,(,) f'.PTUP..~

  • -*-~

. s.l ~,.11is.2. x,.+ I J s. ~*o,.I i* ?, Pr(') ""\\'"TUR. I'***,,.4 I "J:7 ;c1a1-J 3,"'7 x11+ _ _.1..e.. ~!Al* 4 t

1.

t " * ' l t i., I J r* i ---~==;;;;;;; /-i~.* .-;(~:, /, ~TM'S. ~ ~ ~, ~ '* ~ t ~ v.

C. 7. Z * <\\. ?,p E l°oA.b 5T P.lii: <;~;- '5 No~" L.;:, \\-1£A0 °J'u"-'4. Tt e "°" Cowv,,.**~ A...... ~~~ ~o~"*'- o.a,,a..,. \\OCo 0Pea.-,......,c;~,.. H,C.. t1tU\\ I.I~?.'

  • 'l.

.~s r- '[)~ ~.Ooo *'?> z \\,00 M M*" .og 7aG. \\. o-, .,a c..:= ~~o.Z.So 7, 3.1"\\- ~. 8'3 ToT~ ~ t'\\U\\ ?... '* "3~ ~r M*h+~li~ 4,,7 s.1"} (- f1~H l.1..5"' .~B .sg k~'D 3.ooo l 'l.. '* oo M l"\\£.t'\\. \\t~" ** 5 (. \\. t\\' ~ ~~~..

  • '?>l. ~*7 -4.o s
3. '"

rfoT~t. r; t-*.'1'1 I.~+ ?.?..'> IT..... Ka."+~'°". ,,i I '*' ~ /, 2:!>17} .~'\\ \\. "?>> ' 'T"t- .os-io4 .so \\ l

  • Tur"'-

.e1- \\. 7Z.. V) ~,.. ~ ( \\) RvPf\\11t11.. ~'"}

2. *8
t. 71-5'. 0 \\
2. 57 r;. 7(,

\\.? 'l.. 4?. l '1 2.'\\") Ga.~~ 't.'\\ \\ n.07 I 2.C) I ~.,. .,;:*~7.'~J~:::l;;~. * : ~*r1-J}~~1!5t:H:~~~~~.-](~=:~***7*-,--,. ?... Q (t) '?1P;z_( -,) f,pq.(~\\c..) ?,.-11 c ~n 1\\u~T\\ij\\a ~i.Pl'URll RuPTVM.. F.urr~~~ '* 43 .77 '3.7(. 2.. 0 'l. l."7t 1.<.~

5. ~:)

"\\-. ~ ~ 5.0\\ .,._,~ t!l.4'"Z-l'!>>.0'1._ ___ J.17

z. '3"
5. 5 -:a

~. 5 ~ \\\\.':)'f ?.o? ?\\,."\\ 6 l7.S7 '3.~L

t. 7&iJ

'l.7G l.. 0 Z- 'Z *.4\\., z.~~ 7, '?O G.. '\\-7 G..At~ c...o z.. zo.V~ I r,.i+.

5. QI

~. l \\ ?. ')o &..'\\-7 fl.. \\ s If.. 0 !> Z.Q,4t ~ ~~ z.~o i... 7 ' ?.. I le.' ~ *<?.r. 'Z.o\\ ~-- j_ -~, D 7 l 'l, -,0 "'1..17 I I ~

  • e1*c1.'d +

--1.a "'2~*f1r o~*L '~ '" ~ c; *s + (? *"'4SI =1$ ""'~I S 3 CL) e "2?'1"7 - ?v*s'2.... \\£'11L. ~-V"\\"2. t" t;.Q'2l Q "'L \\" ca s *..1c, ?,J.. z l &.., : *--f!:J; -'- L':+ -.2P \\- -VS'\\.::*~ ~ \\ '2.' :.!!...9. I. +.,"" \\ ~"'~~~o '"t""'-J.o.~ (-:>). ~ '1'? 4* l"Z. °) - ~~ '=:,I 'S 4* .£?'~ "-'. '!# I. Cc'2't?.. "'v'B'\\

a~

I o' *s - ~s *~ + ,t';_., t* I "2 'l -: ~- ? I *~ I ?8 = c; b. ' +- \\ '2'4? ('=

  • s + L,..lv I '2. \\

N o 1.L ~~ n J:. Cl."'V ~ \\-\\ * -.a-ra ¥a~ 5::1~'~"' >-c; ~"'o"l 3d.*a ~-..,.....~~..,.....,,,,_..,...~-"'~~~~~~,~~~d~~~No1J.d1~r-0H :ll~HYH:> N:!J. 'YDOONVJ.1VH:> '.l."'l:ll~.l.HYol30 0Nlli:J3Nl!>N2 'ONI.f>NH::I33N!bN3 NOl.LSna~o:>

-~---__:_~~==~=-----=-::-::-::-:~**---- pAGc=- B-2*7 COMBUSTION ENGINEERING, INC. ENGINEERING CEPARTMENT, CHATTANOOGA, TENN. CHARGC NO '2~ l,~ - 5 NUMBI[" L - ~~I .. / llHIEIET Z. g OP' +B I\\.. -- CATI' S / / Y / ' 9J av /~ (".....i HC:RIPTION. C * "7 * :-Z... ?i' '""' """ '< Ou=t L-ttT N o,z;z\\..£, CHECK DAT ______ gy __

c. 7. 2. s ST II... c;: !J '?,

EVA""" \\J "-\\ '0~\\ c, 7. 2.. 5 - I 'P'1.,,..,~ "- 't 'M E£,.... t3 ~ I'\\ '" E. rx = 2.7. 4.~ -;;- = '?,7} T 11 lt"N ':* ~-:- 5. SS+ ~7,1 "33'.'3 . ~ \\3. 0 /r" ';. -1. "Z. 5 /-:- '* 7 "'} s =--Jc~-~),~ ~-(7)?" - ~ .. t, \\<st. <Sy =- 4 1.4 1<.s 't ~ °:3!>

  • O")

I":. \\Z. 'Q T t4,,. "" ~ p;.:: s. e:, s* + '3 o, (7 '3 =- ~ s,.s t (6. -::- I "!>. o r;,.,:. - I. 1 'S" ~~ 1'2.G.o ......... 1. '*~~- 1* ~* I. f ~-

  • ~ ~ *.

~~- I .r: l

  • .:I

~~?. I* --~t. '*1{ .:.11* ' ~.

--~t'D<"?==* m;:' ~ P/9GE B-28 NUMBIZ r - 5' </ / \\/ I COMBUSTION ENGINEERING, INC. ENOINEEPUNQ CE~ARTMENT. CHATI'ANOOOA. TltNH. IJHIEl:T "!lg O~ 4g

  • \\

.'.11 ~

  • ~

.~ CHA1'0E NO '2 ~~ (, - ~ . **OH C. Z '2.. ?13.1 "'en., tl.t~orr N o"Z 7t..E !I . DAT" :; ) I &f I I. ' llV A,....; CH~CK DAT BY~~~ \\ ~ \\:'

  • c. 7. z. s cs T~ "= s s E v~\\..v A. i-10 M

-~.?. ~. ~- '- Lo c..,....'- Ka:knf1."'~"'C::. }'\\ 0 Cl. to'\\ ~ '- Op i! 11. ~.,. I "" (. t 'D C' s I Go"-\\ ~ ;' I $,.. l.C 4- ? I p IE. R 1.1-PT u TI..... "':. ~... 10 ~ ~ \\"Z.. D~ \\ 0 11-F..,, ~ U 1Z. 'l., -t f>, P~ Lo A.~ tf; = ~.. ~-+- S, I 3 PAC..~; 2Gt 5Tf\\.li"S.~CS ~ '!:"* z. 7."'"""" \\'2.o; = \\ \\. °'.) ~'?. ~ ~ C' Y" *= - l. 'l ~ A~Cl: .q_

  • sTl'. ;:- ~ ~ r~

't a.k~,j v I!. T "12 N. s, '.;. - t;. :: "3'?. ~ ~ -l-I.'Z S - 4' 1. 1 s l< sr < S 'i ~ 1-1.'\\- ~~ c. ~'Fol\\. Nu.,..,,,..~ l)prtfA'll""'- -+ z(P~~l~'N. 'S1<<;,l"\\1C..J + ?d~t. R..., ~"t 1.H\\.ft. t~., ii ~;~ &:= T' ~~ ~: ~...,, (*:*' ~-: 9. 4 (:. ~-: l~."'3-Z. .3 P~ttic ~fl f">p, ~~~"' (1. t. 1 "? l 'Pst: LoA'D *cs T" ~ g s r; s ARE*. r..,.11 /';:: ~. s f '* 4,. ~ i3.Z.' 18 ~ z. 7.~ "i '+. ~ '2. =4~z. 'Z. ~: -l.'Z.5 5T~r~~ J."""T~l-.~ITV r,. r..,.. ~ : S: t;... -~ ~ 1" "!>. "t7. \\<. ~ 1:.. <. l.l Sy-= 41\\- 5. '=> \\"'- '"~'I .. } I

.
t,
    • ,I

".'f..., ~*

~

I i_.l.'

  • i*i *,

, I~:*

    • f
.~~.
.
.;1*
  • c !11

.J*;.: t .1.. [ -~ H~?**

  • . !~
  • i'~-*

.. ' !>ii]

  • ~**Sr~.

'\\.,.

  • .-**.f'

. **!f'~... !::i ~.. ~~

    • ~*

,,~ ~:'* ~** ~~* .::d.. ' :~i1l** ~~~~?'- ,. t..... ""'* ~.:~?~\\l ~

1 ~
  • 11 f.u~*

)*i}'* . ;J't;f;J, .,. ~* _1 ~. *:- t

  • ~~.~f
    ~'
  • ~~.

.* !_ut~* "~i'..

~tr 1;,... ~c

~-.-**

    • }JI
  • C*L_

~l!!~ltt . ~... ~**

  • .;1:1~'
  • 1~.;;~7:.
  • ~..:jt.

'~.n~ "M." )'§' ~*=*

  • i..

,.. *.~ >* ~~i; -t.9-1"*"'.**.

  • ~'l

~i*.i* '-...l'fi .~~*"1:~

  • ~ -

,;\\..

  • 1.

lf*** -.~~*

*~~..

..,_,,~ . *P.\\.

~..

~.~'~ ~*,..,,.~v.:r.:::;a:;a. .... a:e:owa:;u

  • . c.. s:_.. ;

c

  • .¥.¥

... --**--*~--~ s........ ;::~,..-.-* .**, 3.1£ii*!.L.~*l?.?+**.,.*.* +~C..F S*>.ti?.*. 19£....*.. s:ss_::;..'!'?"'."...;~- *

.,._.,_.~!6:.....a.*~~.~~...... ~~~..,*-,~.-~~~~w.~~~~~~ ... a_,.*J;J';z~'i\\~~~.-M~+:t.t,,..1 **~.J-*.. Pr!G 8-29 --1 I 24 \\...,5.3.l Prim.:iry Inlet No?.zlc .Ab~;tr~t nH:! pr imnry inlet 110Z7. lc WC\\S llna lyzcd for pi*cssur~ and thcr111a 1 e ffccts by the Sea 1-She 11 2 cor.ipu ter pro~1:mn. Pipe loads \\J<<:>re analyzed by cl.:issical bca.r.1 theory and Bij lc1ard an.:i lys is. It was found that the s true tu re mce ts a 11 rcquir0mcnts for the specified loadinB conditions. Sie!1ificant ncsults Safe End Primary membrane due to normal operating + design seismic= 16.l KSI <Sm= 26.7 KSI Primary membrane due to normal operating + design seismi~ +pipe rupture = 20.7 KS!< Sy = 41.4 KSI Primary membrane clue to normal operating + 2 (design seismic) + pipe rupture = 25.3 KSI < 1.1 Sy = 45.5 KSI Primary + Secondary stress intensity range = 52*. 2 KSI < 3 Sm - 80.1 KSI "Nozzle-Head Junction Primary me~brane ~ 24.9 KS! < Sm~ 26.7 KSI Primary local membrane = 35.0 KSI ~ 1.5 Sm -= 40 KSI Primary + Secondary stress intensity range a . 6 8

  • 9
  • KS I ( 3 Sm ~ 80 KS I Fatigue -

(PL + Pb + ~ + F) ~ a.283,1.0 allowable Accident - Primary local membrane due to design pressure, safe shut-down seismic and pipe rupture - allowable is 1.1 Sy. Smax

  • 44.4 KSI <: 1.1 Sy ~ 45. 5 KSI
  • ssur~
er

~.:i 1 mnc.I the - 2 . I

n U.i.sctt!
is ion

'.L"hc otJ*.. ~?.1~ wa:; analyzed for the.rmal and pressure cffc<.:C:!:i ..,.1~:.:h the Seal-Shell 2 Cot:1putcr Pt*o.:;r.:im (l{~[. l~). 111e followinz ~onclitions_wcre used:

1.

I::n*J of h~ai:-up from 7u°F to 532°.r*, P = 21.JJ P::iI

2.

I.::nd of coo 1-down from 532°F co 70°F, P = J PSI Dt?si~u condition - isotherrital, P = 2500 PSI ~ip~ lo~d str~sses were calculat~d at the safe-end by cJ.assical bear.1 theory and at the nozzle-head junction by a Bijlnard analysis. Pri111ary m~rnbran~ stresses were obtained by combining mi<lsllr face design condition stresses and maximu111 pipe load stre:*sscs. The stresses obtained were found to ue l~ss than Section III allowables. The local membrane stresses were obtained by cor.1bining .maximum midsurface design condition stresses and maxlnn~ pipe load stress~s at the ~ozzlc-head junccion. The stresses obtained -were found to be less than Section III allowables. l1rii'.lary and secondary stresses ~ere calculated at the safc-e:nd and at the nozzle-head junction. The.stress-es obtained -were well below the 3 Sm range, so the conservative method of combining peak pressure stress-es with maximum pipe load stresses was used

  • The fatigue ar1alysis was m~de to justify the primary outlet nozzles as well as the inlet nozzles.

n1ere-

forc, th~ maxi.mum peak s ti*ess conditions from either
  • were u.:;cd.

n1ermal skin stresses were calculated for th~ reactor trip, 10'7. step, loss of flow, and dead weight conditions and added to the *above mentioned peak stresses. The usage factor obtained is small cind assures that both the Primary I11iet an<l Outlet: nozzles satisfy the fatigue requirements. l'he decay of nozzle stresses in the head was found by plottinf~ stre::;s (from Seal-Shell) vs. distance for prNH>u1*c.:, and by li$ing Bij l.:iard <lata for Lht? pip"' loac.Js.

~-* The ::.iuctL:m III allowa'bl<.?s are 1.1seci e~:cepc for:* l)

Nor~al operating ~ dcsi~n seismic +

pipe rupture toads - all1)\\*'ablci i.s :,*1.clu

2) scrcss.

Hor1aal opurat:int; *:* 2 (Dc~:;i:*.n set$i.1ic) +

  • pip.: rupture loads - allo\\,*nhlc i:> l.l ~*::clJ Sl.J*~:.>S
  • J._

C.7.. \\. ~ \\\\o\\$ ?\\?E. LoA.~"!. G *V~'W. ~~l.O\\ooO.I F 0 'R T"' 'L t°t'l-' M t-..t'-.. "( I""'\\,, &. ~ ~o ~*~ ~ t:.. A "t=. r~ o 'I"'\\ SPr.:c.,~,cbi.\\ 10"""'>. ~o 70 ?-ooz.. \\ \\-\\ ~ )>,,.~ ~u?\\Ul'..e: L u~.'b ~ AR..e \\"o -e~ A';)Pt:.\\l!.C Se~~"'~ i-'T=... 'f, SHll::ET \\7 DAnr },/~t/(g, / -~*~ \\ { +... *~p--(. I \\ i I CONO. F" F1 (l(.'p~-- J.~\\P~ No"Mli\\t.. o~~P.P\\T.!,~~ -~1~~ -2~l.O + 1 ~ OE~ \\G N .0 JC Io ~* 3 - o:a x 'o t~M\\ ---- l'ac=ie {') Cc) Rl.JPT\\JI\\~ -3,4' ~ 10 ~ "-'8 ~ \\o"' I / . '--*I. r.. Mx M\\' \\<-\\?C:. r.. - I-<.* p~ (TM.KI I'~ -1. + s.~

  • Jo.o

+-----+---**--

_ __ -.. __, *-.. L __. -* *-*. -*- - -**-*-.....
.~.

't ' ! 1.0 X \\G,. ~; ~::.

-~,~---- ..,---------------PAGE:--8---33-*. - J~* C,-L(73 j :. COMBUSTION ENGINEERING, INC. NUM1n:,...__ ________ 1... ENGINEERING CE:ARTMENT. CHATrAHOOQA, TltNN. 8HIEIET \\ ~ o.. __ 4......_G_--t

  • ~ CHARGK -

2%(.-8 DATS "3/3,/._"? BY 1'c ~JOH c. 7. I J>~'M'"'!!.O! i.... ~. l \\::lo H*~E CH*CK a:..T..._ _____ ay ___ I\\ . "~ ,C.7.\\.~

1 !. \\H~

?,ve_.... l:- o""'t>S. ~ i ' f,pe.*Lo,..,bS 0"4 \\kt:_ rt'..a\\110\\JS pl'\\G.f!- AP.,f T~ X* "(-j!_ CooR t>\\ ~AT£. ~ '(~"tE M ANO AP.~ CoN vF 1'1=\\ F !:> T~Ht \\-G. COO\\\\t)l~.Po..~li S'<~\\EM OF= Re.~ t§ T'""t::.. Fn\\-\\..ow,,..,~ Ea..vil'"T'O~'S: F-=- - F)( c.o ~ ~s -+ f1 s, ~ ~ 15 v,-:. -f)( ~'~ ~i:i - ry cos "?IS v,_: t'~ M,': - M.c M?. : - M.}( ~\\ N '35

  • l"'\\'f cos ~'5

°HT = - MJC. co~ ~~ TM"( ~\\M ~s - L"t-O '""" ?oo. o -* -* ** *- * --.... J. -.. * ***-*

.~~~.~~.1.. ____ 70.6G.

---+---*-**-*-**.. -**-----

fl r

i,::.

~:. I I* ~i~~ !I ,;.:)'. ICNGINZE:RING Cll:?ARTh4S:NT, CHATrANOOQA, TttNN0 CHARGri: NO*-------- ,5 /.?' /.'5,lfl4 IC. 8HEfitT_~_Z __ h ___ o~ DATZ //*//*:;' M.~ Ah-,,#~F-4< 5~t' R.;.::-.8A-.~.t


*~----------.,1--------------4---------------4------------~

,,&1,,R~r - /../c>.C-/-:",.J 7,,,L

t
"t:t.e~,:-

y~~Ot'At. t?/o"'4 ~Al;" **,,()~ Ot.I 'r p_.....{' "Z ~ "* ';-,.: L ,,t) / t.J M ",., /,!' ~* 7 ,_,41 ${ii cJ I //.!ER,.;*~,,,J~,4 t' I J , J 1/0 t:. /J,.; /, ~JtlO' //J$ .,s-. ~ " I 6 ' I 6.s t:) * $.O,uc' /Js O.S' ""' lbs .J,O Al )6i 2.Z #'ID ( /'.J IZ*".I/() 'r,;.l/J.:. c S. lo-/ AleJ Fr- /bl* 1;..c od'~;-:.1.h "*""~'Pr-tbs )'#.!" ,,4 ~"' l,/ I.: .4C,.,0.S IA.//J.4-41" ~~N.S/~c;/)t=".;J S,-l'A,e A' r~ i.)". /;le !HttMr;t.Jr ,48i::i:./r n./F V/.r~ n~"""'- s1.=- 8.i:JSFO ~4' -r;./r ,57,,R:;t:_ ~.t,1>'.~:-* Ci:IF~ AJC'T ~~r~-'l., ,,/A.Jy ."21T.J/$/;1'1N~.:.~ r" /l?D,.,/!!",...17-1. ~ti~&.JT ,..~~~- //~-.er/.:,,.;~ /P.~81 /NN,1&# l.S V&~y C~AJ.se--"'V/4'?"///&:, T 1~ -*--*-----*-----* I

  • '.r *
  • u

~ f ; IWCW td WI i&Q wacwca

so*. a '.* -

~..__fl!. ---*------------~----,_.,.,,. ____ .. _Plld;.,,,.,._,..,.. __,,..,,.,..""os'""o -* --* .. -~-....-*

  • rw*--*--._...,_
  • .,.-_~?Mt xB"""'#,_e,*ne*u..,,.

so ---**~. '*._I ~, ry I Pl9cf t:;. : (; ;: .:J t~:~ *coMBUSTION ENGINEERING, rNc. -* k-<. ~*r ~L-lm~INEERING DEPARTMENT. CHATTANOOGA. TltNN. OfP

2. I/

v~ }(~. i,if~ CHARQI: N0.~6-t

  • '~

BY /7k '.If Jl'TION ~. 3 &1m.J41('{" .5 Z/RGIC.~VRE° C:HIECK DAT llY .:!,* r.. j.. .t(.; ~ / )

{t.3./o v~.ee
_.ss...:-..s * ~s...v~4~

.1.'e,3...t'.6 t:-&.£m 3 C.ur8

h.
  • ~

! 1-i* i

  • .
    ~* 5~F.SJ
fl~' -

Ev/l?~(;IAn",J..,,_5/.F/.Shue, / f',/'G £v~.R1z. -~- :. 'I(::, . ~{~ ... ~* 4** $'//~All .5 /.Kc-.55. (..(s) *. /Z'F..5-=- sr~e.ss.e-;

  • 1 **

~~~ c$.:;.~,.J ~*,q~~ y* ~aNJ '//l,V/

>v4~

>. *.. 7'NIC.~N~.S5 8 t-J/ . 'Vtt:2~ / l).lt"'-'"10 ~.~.. /?Al~-~. - *e-

  • .:~
  • 1
i;*
~

~.5 -;;-,,e ~-.!U ,;~*

  • ~'"'

\\.~. 0 /,,,,.: ~- = v,,... ~~ ~A _,_: ~ ~,., ~c:>A.J.J.. ARtr: ~: ~a- -,-/ ~: '71¥4::" J'/t: ~,R ;- r#~ ~IRCvM~~,e.

  • --*,~

/./~ r1:- ,Ve Y//.~"- D,,AJ.~ (/JC C. e,/ ~.S ,4,.J() -;--"#~- ~~*

~i

~,..,... . *~. t* l f .s ;-e.~.s s' nv7?:AJ$/;_--y I.S ~ t: $ c.J,;! ;-; /IJ /:. t.:'-A$nc l,ev,:f!' ; / ~ ~ ,,.:-'1 '-t. CJ&.J/AJ d!- WI"- '-. 4 /,,;- . ~.: ~ "~ ~ Fr;AJ I ~ .>..S r

I l'¥'t *

-,; r -

  • --~* ---'-- -* F~,.J

?... I i.. I ..S -. ?' ~ ~ S" ---:--- *- -*t:q,.J. 3 ~ /HE /J8oue ..! Y.S /FJll't ~r: rJ.I ~JS" G J .l *

rr Ir. Q ()!'1-77 () "-'..5

/..j

  • A"4' 7

..s~ :-" ~,;,,:-/ e-a ~ 7'/~,.J '.{[ l.

}..

111e- .:-"""""'""'4!- f'£~~cR~.2&

  1. AY 4e

~J4'9.D

  • 70

_<ccr /,,e . A '1L ~_s,,r'/C ~~c.LJ -.Sc~-;-/tJ;J dAJ A.C. t:'d"VG~ ""'e'.,0 . WP/~# ."'1//~ L RE"5/.ST {';./£" /,t:;,4/)~ : ,4.$.S cJ,.,_.* Ja 7-°# ~ /, c-Q IJ /If 7/o r.J~

1.

l'/N () ..3 A,eE .sAr/~/c/.) /IAJD

  • ,;0,1. I/Jr eQ,..J 3
-"~.

/.NE ,,J!fL.t t:JW~,St e V~L v,C ~,C" .s -~' Ce:-,111'"1.. /-r .s,, ) ~µ 'liil

  • * [.

~;*

1. :. ~"

.~1*j i r1~: i'.;. :

  • .. f '*.

l !l'.:

~1*
.

.,. r I~~, ~J\\Df jw~I !kU~ 'tli*fJ i I r IW, ~~ ~- t' ~J ;[. i~~ ft .. *l : ~r

~f.~

  • r.i*.~

. ~-~ ~

  • 1~~
i. tli* !.
    • .it:'-!

J

  • ~*
1!}

f ! ;( '1 ~' i

1.
  • I I

~:' I l -tf.r !~ ' ~ ~ I ~ t

  • . 't. i ii/:

~.. .)

r ;

. *1.

1. I f
  • I'
  • 1 ~-(

~~.:. .,n-. .J. 1 1, '!\\. ~-. ~. :1*, ~,t . ~( .,.1.. ' i*~* lfi*. 1-.... ~ P/-JCE B--3.7 NuMe2:rt C - I 7 2.,;, :.<. COMBUSTION ENGIN J'-JG, INC. -f.... ENGINEERING DEPARTMENT, C ~OOQA, TICNH

  • BHEIET I 6b 0,,J 11

( ( I ~ .. ~ ~~t CHARGS NO 896~ DATE "f- /'/-~9' DY*hb '. }*. C) ;f' DE5CRIPTION. C.3 'f,e,,,.-,14,,y .5-c.eyc..rue;,: CHECK DATE _llV-< -~Ir f1 ~*U l: l r


~l...

(S#4'u. 2 w ~)./c tt'..S./o $ /"2 8.5/.:.S

    • . C.3./a,6*
  • Ft-~tvt 8

,;;.,,:- 8 6~.~ss EY'Al.J""tJAz!o,J_ - 5;/.S/H/~ .r'./?./'-!"- ~ ~';-c.JA?~* , rs.:..

s

/csJZ = Si::, SD = /so~ 1-' ~ 5~ l:e,;JI\\) 3.a- . /#~,J .So A~ ?N' e .~_j.S v.11'1 ~.!) v/IPJ. (,.I/.:" tJ.J /A.)~ o.tt:f' /#/:' Y/e"'- 0 .s :rR1T.5S. ~Kc:'CC.. /C:t .s ;,:e 1/: "1 ,&-'1t.t.y ~tl4S7/c.. ~12CJ.U -. S#c 7io,J /)NllJCIJ.AJ!.. IS /) 1:vet- 0 jl).;,:D. ~"' ,N!V 5e"C:. 77,,,v a p,,,, ~. >" c:le;~-*

  • --t:~*,.~

PP.. ~ - *. ~ w.So ~~(9a ~) e-a>AJ / b So /Ht: .S /.Kl?.:l'S/?9..S

<,;
s c.. u ** /1AJG-Fit<"""
r-r~,-

. p /.?'"A f) . )14.) /'. '4 /IJ D ~ 1-e:1t11'- J.~Aos LA/IL'- ~.E E'VAJ.. v4/9~1) tA.SIAJt'. F fP,..J 't. I 1 2.1 / 3 ~17':1

  • .*.St> r:.5,.,: :J..6.';;'

~.s,:. 7:4/F ~~41N4;-r,*o,.J. ~,c- //'/ e /) b...,4 0 l...J,T).s e i.s M It:. .I ;A1,Jo. p I,~ F ~ V;',':-',;,1/fC ~ $"//21,?",!,S~.S VV/~4'.. Br-c:"Y,~ l.),d./,,Z:-J) I E" 4' i/A Ii a,.J ~ I."'-, ) 6 / :z..... ' 3 ~ *. wi r-,,i.,1 /. I ( ?'/, "/) :. * 'o/.$-:_r k.s:. * .:,,,/.$ />4/ t:-. $.tJ: /./ ~ ii he--s .~'.I {*

f ~&.

11 ~"

i ).!'.
~

\\~ - !'j .,\\

.t
  • '."l

.f.f ~;~

.... 1*.

~*I ~-

~
~.*

'.*J ft H f.~** ~t ~-- !f '"'"'" n l~' ~.; ~'l .a f} f,t, ~*r ~Lff: ~rr

  • l{:

~,'?;*,. :~:; ..f!..t i;. ~* . *1

  • ~1 t*.t=:

Jl~-.

  • jt:*.~t l ~-

'.t >

  • ,t. p 11>

'r'{

  • ,.l

--===

i~..:~

  • ~

~* r. ~* *' ~ .... 1,*

  • , \\:

(~µn.e) 8 tt:-ur 8

  • t§~-

~~~~~Ar:t--,p, I" I . ~ .... _..?,-* 4,e,,,:,,19,K 4'hl..l 4~1?' .t.Ot.J.4',e . r#AAJ tB./$"~~. ~~;,tl,V~~ ve.1;- r-.. (/'"1" F 2. J ) ~c,..)$/~C-A~~ Aler -f"~~l ~,/II~~ I ---/ fT' ~--*--I /,/:-~*IO C /M. V~ WFI$,,,... T1' /~"'/a* /fl *Id*

w~ "'."1 I J -:L \\ I /(V

  • *. ;or.::t
  • 4 *g?: ~ -s ~ ;,s*£"1 =

"t ( *J Ir 1- -c (z6 96-lt.S'"t J( =. i s-s"' ", s (' ,~. =* '£~ : fl'/ =.s, £* ~ i fl/,a 6 "/.$.: fl(.~ - w : !!/ 711"~ r"Oc I ~Ott $f'YIPWt77 J ~"'1

  • rc1~ ~*1 =I\\

sd*;t ~ p1.r ~ * : H r-;~;~~ ?/ftVS°/.#'f" 51/"f'.J ~/llJ' & Ill ?1,w11 E '=H 1'dl't17

YP';~ Ji?::/

/ "hi .?~1'?.J. :;\\'?.:U}"' ,/t?VIM/~'7' E7NOl.1.dlll:>S3C !1-n~ z 'ON JJDHYH:> I YJ..LVH:> *.u.z:atU.YVd3C DNIH33Nl~N3 "ONI Dt~l~33Nl~N3 NOl.LSnB~'10:> . ---*-*---------- *~-----

t' -
  • ~~ 7

. *1 I

~

~ t... ;. t." i *:j j l'

/

... t*.r . *f I -~

  • *J

~ I*:

  • t*

1 ** '. r**

  • .1 j I

n fr; r I' 11 u.:

v ': 0 A. i ~~ t' ~~ -~. ~ l! ~*

  • ~
  • f. ir*

-~. l:*. . f t f i f: }i.~ .~- t ~* ~~* ~ . l.

  • ' f.

~- !: l ~~* i JI ..r. J I 't't. ~-=- ;;- 22 =.mn "";;.(s:a11'7J ~ '.>. ~-" + 1'3. ~G. = 2.,/.. J2.

  • ~~..

f!J. BI fb =- e -* ~ = 1..r. '18 f',.., : 0 ~ _.r ..:>.s :

I.~ = 13. ?6-

' a:* .-i. ~~

  • j

! I l ~ } I I i I J. .1 I I . i 'I '*t

  • I...

G.3.10 _ _fL_~.s~e:.. (.51-1e~~ ) C,J.10.{, _/'-/.:->::::!._ 3 ?'rr S ~.5m1c.. -r C.-4s-': 1 p,,,: 3.S.3 'I- ~.S-6 :- ( s" :. '{~-..Ii) k... //, 0;? ,P0 ::-

. 9 z "' ~ '),..>-..1
-

~~¥r-~~--t~'-l...!:=----~~- 5 s :-.f)6

z,t1' P,,...: [?ft S3 r-1 _______

.;.__,fc.. ~!<.:.::_____ c:::>.'=::. fl :I Y. 7 :di-----------------f--_.:::::.....~ ~ ; * ?~.i. :2 I. ! 2 =.22,08

I 10. ~6 !..---

70 ~::

28. 99,: :Z!i~ N,

~{~ ;; ) :

  • 9~'1P~

P,; )qJ.{i'-' = f (;a. 9G){.sp'l')o) : J 12 *..'2. / ~j ---*

~***-.. -

  • ' Wdtol - - - - - -

f',., =- 3. s 3 _,,..---......----------'0----f(...-- '°'1 :- s.:> = ~- 9.2 r /.S-. '18 = 2..S-.. "lo - ?b -I 13.1)(0 : /&/. $'1- ~-:03....:

44 -; KSI 1 *.3 KSI .. mize flow e t ~*' 119l* I

-e The

':eS eam

  • =imes ector.

a

ial I

I I -:-imary ; . ne). I ~ 45 PAG£ B-4'3 5.5.3 Support Lugs 4 Abstr~ - 'llle upper support lugs were analyzed for the specified loading by using classical machine design P.q\\!ations and a Bijlaard analysis (Ref.20). 'l'hc str<?sses satisfy the requirements of Se~tion III*. ~Ui;nlficaut Results (all material is SA-302-B or equi.v.) The larcest stresses in the lugs are T =- 10 KS I <

  • 6 Sm
  • 16
  • 02 KS I (shl*ar tear out at: all *pin joints)

~ = 25 KSI < 1.5 Sm* 40.l KSI Bettring stress on double shock lug All other stresses in the lugs are les~ than 607. of their

  • al lowables Pm+ Pb = 39.5 < 1.5 Sm* 40.l Key Lug, outside surface of shell

~.

~...

. *;it-.*- . ~ I CJ---2] !e-1 ~eJ FIG

  • 17

ti. A. Stone, Che ~1.nnooco . lluelear Co;;i,pooen":. Dept. 8UIUlCT COUSUM.ER-' S FO>.fER STEAM Gfl:::RA'I'Ot1S . COUTrlACT 2%5 .* v. JC. t:l1~l.r.I h tt. J\\,me 2, J.~6

  • cc: P. P. Bill, Ca onc:ioga (EV

..._- J. D. Cravtord p ~ - P..S_ E-34

... ~

4*..r ~ ~ ¥sr:J!f~~ww7!~ *. .At a uetine he1f'1~~~noor;a, ?t!!y 18, 1966 to d1seuss the steam senerators CEUD ~ -*

  • ae;rced to turn1sh support loads. These loads are rorvarded here.in.

The enclosed

  • akctchs sbov _the: c;encral location or the various sup~rt PJ1ota.
    • .Vertical support 1s provided by Z. "Lubrite" bearing FJd.s over vbic:h the stee:i generate:-

. v.ill slide vhen th~ r.31n coolant pipe l".eats. up. A. key 1a FOvidcd under t~ base to

  • . 1'orce the cencrator to slide 1.n a st:-aight l.1i:e: A stop 1s :provided at the er..re?:e*

.

  • end ot t.ra'\\"cl during heat up t.o prevent p.ny turther i:otion it' a I!:31n coolant :pi;co.
-Upturcs. ]?old c!o\\ra finee:s *&re also j?rpVided to limit t~ up°*"'al"d :OWI:.ent Ot' the

~em generator d~ to this acc:ide~t.

  • ~. -~..

Svay1%18 or the ~n;rator due to se1sl:ic loading, eccident*cood1tions or v1brat1cn is

. --~*..... :

l.ilidted by a system or *keys and shock absorbers on t'h.e up~r cylilldrical part o~ tl:e eenerator.

  • Up~r keys ~event si.-ayfog in tbe d1rect.icn ~~ndi cul.ar (. : * ) to the JLC. l:ot leg vhile ".st.eek absorbers" lll:it. tl:.e 51."a)Pllg in tl:~ direction parallel (X) to t.be bot. leg.

~th or these devices allov the &ene:-ator to J:OVe

  • slc-.rly in tbe

.41rect1on ot tbenr.al g:rovth Vith virt.uall;r z:o rest.raint.

  • -Sketch l sbovs tu OVel".all. -~rt sc~r.e* vhile s~tcb!s i ~

3 sbov in zcare C!etall

  • -tl:= err~er.ent at tb: uz:er qlinder s:r:d su~

skirt~ re~ctivelJ'.

  • ... A ~

ot tl:e su~ load*b:g b gben 'belc"J. ~as* m-e ~ w ge~ral.~ ~

.* *( ':". *: * ~t. CCC'Jr St t1-..e SB::e ti::l!.

T"""O Sets ot VSl\\:.?S ere givai i.e. ~ lia1.s::1c loedil:.i -* ** *. * =4 'tlllder the ac:.c:1cent condition ot a :::ain ccol.D.nt p!i:a bre~. ... **~ < *.... -~ ~....:*.:.:.* -J..XO?.lr.f ro~ &: 1*~*~1TS 'Fi\\C:.r SOPft'."fIS -.-_... ***-~* <: -.~*

    • -~:-~.:~}. ** *. *~.
  • **:~-... :-...---Se!~e H.e. P1~ ~sk

... :* *.~. *: *. -: :' * **a.o. Sutroort ~-drt

  • **5 *
  • ~: *.. **. ** Force - Eor1 zcnt.al, lbs x lO

.." *.:: 0.3 ',. ,

  • 3.0
  • .. -: :./.. *.:;. l"orce - Vert1c11l, lb= x lr:I'
."*.. * *--~....'.'.=.>_.::_*:._*-... '.;.~~ *.*... _;_:::_:.':**.. :.. :-.*
  • 3-0

.. * <:.:_,*;: *.. '.*."... Jf.ommt - about l:.or1:.0;ltal *axis, . ~..... . ft lbs x lei' .... -** ***:5 o*-..... *

  • 12 0

'. : :_:_fr:}:.. :. :::~:;-~ts ~~:~~--~~~'.;_:*)~.;~;~ig~}~;'..:~o;~:~~!f ~:~~:~~~,~~-0._:._.

  • .. *,:*.: :..7,;,~~-.* -ror~. - : d1!"cct.1cn, lbs x lO..... *.. * /

~~ *:~>!?*::O.l2 -._.:L ***. *. :*.: **0.3

  • ,........,- /
-*-~'

~-- ~r kc7 ~.;. * . :*.-*:* *"<.: ~; *_: *::--:,./<* :;.~: :*. ~~~:\\ }::~~1 lt:f:~-~~~:~>*.'*...

  • 8.0. Shoe.* /.bsor... c_

.

  • 6.. ::
  • _ :,.... ;:,..,......,.. _

_,: :. ~~ :*.

Force - X dir~cticn,
  • 1bs x 10 * :*

~-. *, : * ** :*..

-*.:~~-.. ~::**;.: *.: *.
    • ~-.~*: *.* ~**

i7... -~ :*.. :. i:cr shock &bsorber _. * :*." :*.. :*:'/'.i:.: 0.1 * <<_:-;*,_;.; *. 0.2

  • :.; :_: Vert.l~nl 1*oentfo!1 ot: *u~ kc:r and *shock r.b~;rl:.~~- att~c'!"..-::~n~-~ ~~ ~s ~lo:.e to t.bc Int.er-

~ct.Ic.n Of t.l'~.CO rcot. d!:::t. c:rHr.~cr Dn:1 th~ CO:l!c::>l t.r::.:1t!c:t C3 t-oz:i"ble. Fo:- CE:::l'.;: . -*1:~1~t1on_* _ihl~ -~.'. ~:n ~**=.d,to,_b~ ~ -~~~r~.--7;~:,t~: {~:'.*r~~-~:.!:"**. -~ ::* ~~~**:*....... *. -_;~/:~~:~i:..::f~*:.,:._:::i~~=~--~~~:~:~;:::::_::~~~-~::f;~~~~-:-*:~*~-.-~_:*4:~~i~~f:~~~::::~-:~:*:......

  • ~-

._,,.: **~*~-w*s..- ..-*7----

~-------------.-.----..... --.-..-...--_,~~M£ ,._~~~~~C~~JA~ PA<4E B- ~S-COMBUSTION ENGINI::E:RING, INC. ENGINE:CRfNG CE::tARTIAIZNT. CHATTANOOGA. T~N. CHA.ROS NO 2 9~ '5 - /:S DE'SCRU2TIO t:',,,1t:) -~ V,.,,Oc.i,tl-:- r-- tC'./t:;, I a.s ~ "'-<.S /t:' ;...,J I I r i ,C &.S/::J.,.J P4 r.-:i NUMait:* (.. 7e:.? / GHll:ft f' OP' / f ~ DA,.g. l.t - /- ~ re; av.*. -;...,.-,e c:Hr,rc;c DATm:: ';,~I~; av e11. iv~v I I : P-.r1-3'f/./.P'-S~*.r..r, l',J'....r~- /J/

  • r.,,y.e A.Ri!E e

0 h=* -2 )(/a '" /6..t I

  • =. 2 ()()

,1::.1"'.s. r=:.: = -tr.. ~/()" 16.s r.. (!$ Ct:J ,.t~ /11.~ MAr.e--~14t. . ~ .SA-. S-3'3 - ~-RB - CL I ",S,.,.:.

l.b.)',t:,s,'

§ r-< /t:"'t:1°~. ~-------.;...------------------------* - . ~- .

  • r

! I I i . I ! I ! I I. I I I I I I ~ I

  • I i

I I I I,, I I I L I l '.J I I

  • 6/.l~ll"lfl rvCJ
  1. U-~~F

..?~~ ("Y/ fVMO/Y.$'

"'" ( 7"' ;#,,. '?(}',. ",9' I" ti' I ft I')
I (VO" /,#':; '17

~S" .=l?';;t'~ f" .,:;' ~-

  • ( ~/ ~ _,-..;;-}

~;Y~..;I' Jl'#'?f?Pf<I'~ _.;1-;Jfll'~ .:5'tvt; fl' ~ f"-'S".A?t'?'l'Y6" C'TW'7'.L'IF'

,,-.;~

.??t?C?'-#d/' ~ .i'?'?tS"'i"<.J.~ r-~1'1 ~" ' (~I ~ r"'~ ~J.I.:>'$" ~.rs) >-J- : JP~r* _.,.*o I. . "(6<7,, fZ' ,jl'~6J'~

  • f~ r./ #~;;>'I(?~.:?;)'.

7°.S°.$' ;>'~ S" )I I I ! 'f/!'tJ'_#/11".r .;;-tY~ ,,,<..:"*' FUtl'>" 7.,/l'YI ,,.,,*.-,,'l""M f'Y/&I. -ff".1!'1?f"lt/$' ..il/'U) l'/'1,,, Z ..t f?O {/ tJ!' (7'11'0~ _,4/7,'#/Vl (V/,::I

  • "9rvt6'~.?P ri/'I"~

~ t7~-"1'""'?

  • ;s-:Y~-f iJ1';7$(7

"'c:; '7.i'~(V6"h'7fVt'? ..?9 ~-_.,/"...(I.? 7?/M

-_-::-s-,:-.=7,YJF
'..;;.'r'J"..J<?

'?.,/Y. "( g. ~.:i' _.:J'$") l'Y/d' l/'.11'7P'ff$" .,, h. .;"t:? . :¥ J"'~.I,.,, (i' / t:? ..:? ? "I"'>' rv~ ,_..,,r.W/.Y'(Ji'N fYG t.7-~f"IY p S-/ ~~(7 7 t"l'.>/f7tlff~p/ ...:7'~ (Y/ (7r""{!/ " $'?1'7 7 .;,..,,,,.~ (¥.-' v~ (?_<?ff? _.;-.rty

  • Sd'v$..i"tV L-**-* ---*-*-------*---
    • --*:-.1 I

C)f'-Et -*;.J..:.... ,_ ~ 7.::. / / siva ll:>JI H:> .-';;._;*-,' ::aJ.VC _(£3'1>;"' _:.~. 'H;~. ~/:7 NOl.l.dlH:>s:!!a . l. i ? *.:;; e.,;,,< - ON 2!0HYH:> "NN:IJ. *voi:.p>-("U. VH;.~; ~J.~... d30 DNU:l:i3Nl!>N3 .3'::Jf:/d ~ i ._..... u *.::-!,., 'l..r-r"'!'.!lo.nc-.... r-r '"",,...,..,..,.,,..."" '-/..

-,r-- ,.**I .:I COMBUSTION ENGINEE?11NG. *INC. ltNGINElt!'UNQ C&JllAl'tTMltNT. CHAlTA.NOOa.A. ntNN. CHA~Oll: *H0.2!!:;_~ _... fi;;;._ __

  • c.H'I *.z. __ 11.r o s~

f,t.1,-~;I! 7'"1~ &'~,.- -J'?#i-A I'_ ~*o

r
::;; = -;;;- :: 10 kJ.' <. 6 $,...: l,.o: /t'.s:

/".: t J'.& = /Od,..,!"$. ,fl a Z Ji 1 z

  • z..r
  • z r 10
  • n;:..v:t~"-..J - /19.t'r ~

fi= ;.-*r* ~ 1z#s- ~"',* < s,...- z.~.7 ~s..

  • I I'=~-~ :/*o

,9= !1!-(A*J):: z(3*'f):8

c. - 7 r7,p5 NUN DER------------------"'-...._..~

GHI?~ 8 o.. /1. x. I *... -

.\\_.l../Mt::::U~ noN ENGINEERtNG, INC. . ~ ~GINEERING CEPARTMENT, CHATrANOOQA, TJ:Hf.f. I' CHARGIE NO z 9,< 6 -4 CESCRIPTION C./t':' 5've~.R:- .Lutf,.,f ,l?c v8.a- ~,,..,,, ~-<' tG cJ ~ C,/o,'*/- / 5-r~=-.5.s

..J

..t.11.,. /',.p~;r /? 1' ~ \\l

  • i.

~ 5~r-A,,e r.;,,,ee>ur 7.:- /",o k.s~* < /~,,, z. k'4.: BeA~.1N1-r.: 1e. a ~.i,: < 90.0.r '": '77rl\\J.S/a..J. I"':: /~.~-~$: < ~~.7 k J.: 8~A?A'1AJ&- .Zt!IO r: ~.: - /fS ';.fl s

- z..r.",l'J: < /,.r.!., = -fltj*S'k1."

~ ~=- 1'1 z. *I ~. NUMl!lfl:ff BH ltln'. ,{$ C-~?S O'l'__L.2_ DATIE t-r*tt:?" rt.. -;~ CHECK DATZ l/f!l /'-i DV etf./'x£"1' I ] jC~:J @_] ~E~ P~~t=B-4'8 ~.. nJ~~ l 'l* !. I. ~. - ~

. r.
  • 1'.

I...

-1
  • .. **~

~ I f:

.F

~ I "1 I

  • '\\\\

I ~ ' '<=1 I ~ I << ,\\ *-- .~*.-...:...... ~~ m z:..a: *

  • =-=-= =*

-au w: usucz:C:..____ __ ~----.... ----*~--~


* ****----*-*------------------.. ---------**iMttslllO*----*--*

lllilrtl:lii"~g~-.~~*:- >( I [ / ./~ OHIEln b 01"--=*-* -* -- DAT'Z Q-/-~ < a'Y'.-"'"7... :;,-- COM8USTJON ENGINEERING, INC. ENGIN~ERING C!:?AltTM!OfT. CHATT'ANOOC~. T:cNN. C:HAROZ NO ::? 9l'* ~ -'1 RIPTIONC./t"' s~_,,.P:J.t:.~ /.t.1.~.S C:HiECX DAT" I/,.~ ;, 7 DY. r f(,,... £ r. ~ P/fcG" B..;. --1'~ --*-----***----1 .,I .K :".s-.,. J~: 2i:J,, ~ = 9.* ,4~Jrt)/ :- /~O f :-f o~ 4') = $$3. z i Ve :" 6,ac k.1/#S /ff"' = ~ e :-~.Ye:-o ,,.,,.~~s I l l

  • 1 r I I I i..

I I. 'f

    • I**

J. r J I l l

  • ~..

-~ COMBUSTION ENGINJ:ERING, INC. &:NG:lNEERINQ OEJl"ARTM&:NT, C:)'ATTANOO<lA. T~N. NUMD£R c- "'7~. A'9GE SHEET Z o~ 19.. BI-5(:., 0CHAROK NO ;Z,9,~.;.,!S DAT&LZ-/-6~ avbr? we&e.RIPTION0/~ $"ut'&LT Z ptt=.S CH!:CK DATF" , /t' (~? sy_t.tr.. 'V£ r

  • t

~ { .-V-,e&.ss ,..J $'-:f!~oG ( ~~/ ~t.J&-). I I ~AJ:J11/,l. I I ! ~,,.*e_ /f/J,,,,,.,,.,,. I

  • /-11.-.J#w,,,,... "...,,

Pz- "'":..S-'f't:JO .t-1-~ ~:r- ~l.S,,OAJ Atfo_,11Jr N,-:- - f..,,.~,,.J11,#/1!> ..!.1t1rA..Z ~111'1 ~'S'9 ~

~tt:'O kl1'3

.~.... 1' :' /. ~ ~,j.. ~.-/.:..o,~?"""'.:;,.:-..rr~.s:.i ;;i,,e.r.;..~,;v... 4*,,.:<<~ £"'..,,,,,., . Arr,,,~.u,.,,,.111,-

Q

~;""~ J, /~ ~ ~ - ~* **~ ...,, I" f'..& ( J11:.ZIO ~.J'A.#..:> ) "---~----~~--~--------~~--~----------* ' ~ ~ t ~- Z.1.S1i7~ ~~;US /11.t,,;t .RAP/US -r11.-~<i'lltn~ u"""'~~J ~ '"'~'~ ""~ l:>llf!J~*NJ~ON q= //~ ? ,e1//7..Y¥/ ~_-sz~-:r'. -1 t: i1-Y-8/_, .I~ ~,. d = ;..S- ~ I _.sr.trSJ A. ~ ~" __ j.~. r~"-~j C-.-J'.*,, . r~ *iii~,;-,( ., *?*I j* i I I :... ~g 6.. I' I .:~ Flf..1.*.. It

'\\ *,.,.,

~- ~ -:;;"is-*.w. f -- ""':/ ~ - j1A /ii %,$Zit:,t:J$7,,zg At' *r.v~:: J3 ,7.3;~,7,s-:_.,;u! .u.*,., / '-!"' ~1~74'.~.:*"7'*,/d$ -;tz-'

  • l,,.t *

/'

  • tf./?,. 1.r.n_;--. '~:;.; '._s;/~

IJ.1 IW}j .>*.,I,/* I .,/I ....... ~.. I I

  • -****if-J:!!~tf.JS

'1/ * -f'% i 'Hr,,;~ ~ J,r>tlS~ I J:, Z .* ;:_Ne.~~ *.11: !:-~ ~J :.¥of: I ,, *{Al( ~p F°"

  • TlllA
s-:o Mr.

~ n7° "rN~: ,1.JJ"'ll~ ~ ,.;:..1J?t,.zJ.rJ 1.-z.t.;.>"91 *.;i Q 7.t:? li.!?.o3 1.J~~?I ?.~'. i.. ,GI 1.:1:1,,,.c I' . ~ .t I c:

  • ,.,...f _,.....

'I....

,,. c
"'1,..

_11!... ~: ~.$.:i =,N;' ~.3-f' ';;~ 111J z..n ~ *.or8.~.:.

  • .:,Y,l

~~-~ *- I ~u.-~. ~JF$$ ~ ~ ,u~I~ -~---...!..---;*--:;;;*12: i -- ~ J'r~~ ~ I* I 1 s !t;""' ' r: .,: ""'r'.!*fiJ"'t"/(~*r.)~#ofT&J fZ~.S3 .l.!1'-"... s.. L.11,e~~,4, ~... 9.~ Iµ; Lbl 0-~1. =""- s** /tr-*l'itt -1r'.~* ;*. ~.... .*. *;::-.}..., ... *.. ~L'.U.i ::~.:.. o I**.

t. ;,'.

I, o I r rill\\J '*1' ~-----* t> ~- .P"_ --.:.-~,* -'-~&i. ........ t.* C.-C... :x.c.. .>~. D~

  • c
  • ~~~~~1S COMBUSTICN ENGINEERING, INC C-1 Page Number AppNt)IX c*.

SEl5/11C. REANALYSIS 6F /ti£°' C<;NSV11ERS Powel? KE;qc-ror<

  • CDOL/f\\JT PUHP sus::rEcr PAG ".A/o.

/1£Th'OD OF tC).>VAl/'SIS 5!Jt1!1t/R'(, OF, RESUI... rs . LIST OF R£F£RCNC".S Delt41t.E.D. C.'1LC.UVJ770VS: c-2 c.-s c-4 PUH P C~:SC'

  • C-5 All1P '5UPPoe~

, c-7 /J/lr-Jt.rr10qL Jftror?..-r ArrAcJ-/f-'IENTS. c-e * .¥4.:P:*.. : z J<<;s x;wwscs.

~ c:d POWER

  • ~1-.::5 SYSTEMS CCMEluSflON ENCmE.ERING. INC c-c Page.Number

~~~-h...- c.oo\\Cl"""+ P"-'>'t"'?

r.. f.-1.A..fhoJ of. AV\\~~~~~:

The. ~.a..j~~:c ~+,..-4.~~ ~ ~ Q..~~~"""".iuf +o b~ clhr.. Q.c:H~ ~t:o~~ *~ i-h4 o~:s~"cJ~. ~Q.;~W\\iC:. ~4~~*Q.~ w:+h QY\\d th~ O't""~ %\\"'\\"\\A.J. a..c.c::.~4. Y'Q...tj OY\\ ~

  • 1'h.ii.

W'\\D..X..

  • ~+r-Q.~~

~~Yi.. ~t+a4..~.fo'r t+\\4. r-.a.;v:~~ ~Q.~-:>Mic:... c.a..~~ o..rA. ih4..Yi* Cori~~-r\\la.i-:v.c.la.s c.a.Jel.(..lc...+~ b~ a.dehY\\CS t-h4. Y?A.~ ~4.:~M~ ~ * ~+'r.Q.~~ +o tha.. . 'rA-~p4-c.tivQ.. Q'f"': i~ Yl~\\ ~+Y'"4S';)t.~ ** ~* C:.O'Mb' ~Ad. ~i-r-ASt;,4.~ a..v-4. ~wipQ.r~ * +o +hQ.. ff:,).;( e. c.od~ s~:on :m P~r.* F* l~2.~ *I : ~l~w~,~~ ~.

~~POVJER t~~SYSTEMS COMBUSTION ElllGINEEfllNQ INC ll. ~

u. "'(W'\\ "'r"(\\~ '(-~ of' A. p U."'l'Y\\ p Co..~Q. :

Max.~~., ti::.~I 2.1*9' +~*~i ~.

  • PtJ."M p 95 '"'f Fort

'Z.b *b 1 o.* ~I ~'1*~ RA.~v.lt~ ~~~~ G:i.f-~ot'"~ p........ C Pm+ Pe) ~~: Pwi < rW'I+ PB) c p,.., +fS>) C-3 Page Number La c.a..t;o n Cod Q.. Al to w.a.h 1 Q. -s+r-'j ~ ~==,;,I t>hc:.ha.~..ct.. lJ03r II u.vs-=-.2.@ ~ ~fiJ.1'11f 2.1*b7 c:a..~~ w.A.lel 4-l*~ ~+@ ~-pu.Mp. .4-l*S ca.~~ w.a.Jc:t

f *;!f2 POV/ER . ~1..5 SYSTEMS CO'-'BUSTION ENGINEERING. INC Cl*

G2..

C-4 Page Number l.i:..1r~... r Do c:.ka..t tJo. CS"o*'Z. u.-=:,' U&.Lc:.IAAv-. R~~\\o.to..-~ C..OM'\\'W'\\* c,~10Y'\\ L~o~-~1-ol -e 2.4, '04.Yl~i~ t-t. C:.~iJ.Tc.hf:Q..\\c\\ +o C.~n'S~Yl"A-Y" pow4..r-C.OW'r~"W\\~ Oo.v'1el p. Hoff'W'Y\\Q."l"\\,, ~oJ-AJ j~..-.. \\~,, i<r2:11

  • C.E \\.ci..tt.a..r p- ~ E. * ~~~, vJ. Jc:.. wil h<1..\\ YY'\\ to B*~roy, - Ja..c.k."":>oY\\

pu.'r't'\\ ~. Z'>'\\c:, G. c. D: ~a.v i"ho..

  • dcd-~ ~ uJ ~ =?,, I '1 E>l
  • c~. Bj ~+r.A..':1~ R.4.po~t Volt.t-mQ.. No. 'J!A, p.... ~? CA.~~,, ~.ICTIX4Z J:)F!~':

~r:Vr"IQ.Y"~ ~ot~~t p\\,o\\,,V'l'\\p, e,'.)'ro-n jQ..Ck°:~O'fl jQb No. 661.. N-c:>ib+ J . ~~ "ll:}b9. C 4-. o j ~+~~ R.Q.p~rt Volu"M4. No. :Ir A, pi.(...... p Ca."',,Q.., ~~it ~S x 42. P~~ t>t"~W'\\O..... ~ Coa1q-nr pt.4~p I B~r¢'n..)~~~)'\\ job No~ ~J-N-o,64, RAv:'b~c'r'\\ ~o. I,, Nov. 1969

  • c ~. B..) *s+r.1..~~ fZA-polr"t v~ 1~"1'Y\\CZ._ No. JI: c.,pu."W"l'lr Ca.-?ci.' 451A..ppo rt Lu.~ No. ~

I ~'5><=;,$it.42 Pr.";:i~ pr-:~a..-..!$ C.Oolo.Y\\i-plk"""P. C~. l!>j ~tr~';::f, ~po\\"'"t Voli.t'W\\r:.. No. It D, p~'W\\p Ca.~Q. ~Uofport L~No.4-, ~CS"-~Sx 4-2. Pr<';)~ r.,..:~o...... ~ Coot~.,..+ p1.1..W'\\p. Ci. ej ~r'A..C;.~ 12-~port VoliJwe.4.. No. '.l! e.,, P~~p CA.~ ~Uo.ffo't"t ~ tJ o

  • I (4*"f\\or.. ~, * ~1:5 ~ ":>:S x.42 D~c;, p r:wi.Cl.."r~ ~ol~~t pu'r"'\\p.

c~. A-5ME. Bo; lq_..... Q."t\\ol pr...c.~~U.Y'"' v.o..~~a.\\ Cod~ ~.Q.~Ho'I'\\ !I! I l°ioo C. 9. Bj ~+~~~~ A~~~is of pi.lW\\f CA~~ ':>tl.pport L.1.4~ ') for "ZJ5X??>< ~2 DFS~ Pt-:-mo..r~ Coola."""t pL.lW\\f, "e:itSro"'I'\\ J~'°';)on orJ~r No. E>ol - N-o(~4.

~RPOWER t~L.S SYSTEMS COl.IBUSTI0:-.1 ENGINEERING. INC c-.s: Page Number I V. "'D ~To...'.! a..J Ca.. k..i.J o... t i o Y\\ A. Pl.L"rn p U:l?~ : e,~ eowir~.... ~"f'\\~ 'S~~~Q.4;).fo_.. thQ.. CA.~e.. of 0*'2::, ~°":;,>M;C:. cu:.<:Al..t.~+:o"" of R..i4'. C'!> q""o{ -th~ CA.~ia. of O*SS~ 4:>A.:~""':c. o...ceia..14..~;o"" oF R4. C4.. ~44 Aito.c.nY'i"\\a."V\\t r.. ~~~Q.~. fo.,. +hA. c..a..~a. o.f Q.. ~~~~:c. o..c..c..aJ~r-~:oY\\ o.f' I*?. '1~ ( R.Af I C ) c.V.J>.4'""a.. G:Jc.u.!Q...~ b~ thQ. f otloul~~ 4VWl..+;o'n ~ who..ra. l*Zi~ -

  • %~

= "::>,'%.~ + <: ~*w~ - ~*2i) 'l$Si.- *-z. i = ~.z.~ + ~.ot, C ~*~S~ - <=::>.z~ ") = pr;Vl"\\Q.V"~ ~+*~~~ JIJ.4. tc> prc.~~u.Y'Q. Cl"nol 'm.cu:ha.-,,:C4.l \\oP..Cf.~ w:+.h Q... l*'2.I~ ';).Q.;~Mic. o..c.c. Q..} -4. '(" o..t i 0 Y'I *

pr:VV\\~V-~ ~tr~":>~ du4. to pr~~u~ o.~J "rr\\4c...he&">': CA.! I c~~ f o \\"" thQ.
  • '2.~ ~.C:~'S rn', c:.

O.c.c.<<U~ra..t*1on ~e... f>n't'V\\Q.'r~ ""*r--t.~" di..t~ +a P~"=>';iure. ~""ol. Yr'\\~ho.ni.::a..l fco.dc., fo~ +ha. *'$~~ 4:>Q..&SMic o..cc.Q..(~'ra..tio't\\ CA.~Q... To...b I~ I ll~+ -:a p r~*'t'\\'1~..-:) ~tr-4-~~Q.~ f o -r- -the.. ~i X. r.o..~ioY\\~ o-{:' thQ. P"-Y'r'\\'P CA.Sc., FroM +h~~ lo.bl~. On4. ~ s~Q. tho.t ~+r4..?~c.~ TOY' thta.. '$i.( r~C?Y\\<<:> <l.'r~ a.c:.c.ci.p+o.blQ.. b~ tha.. A~HE. c.ocl.Q.

  • CSQ.c+it>~ 'ItI: ( R.a.f. CB) ~to...... Jo.rcl, w h.a..r~

K~I +ha... c::.,oJQ. o.llouJa..h\\~ ~tN,~~ 1n+a..~~~tu.. ~1\\?M =.2*4-S,.,..: ~9*~4- ...J @ 650°F

r----~------'"------------- 1 r;~POWER i:l~ SYSTEMS COMBUSTION E.NCINE:ER1NG. INC R.Q.~~ on ~~c:.+ion ~~¢~\\~ D\\ff 1.1~'1.'9 .Vo..-t\\e. Scu:i'ion Nor,~A FIQ.~Q./voli.li*~. . floltin~

  • Flo.~.a./valut4
  • ~oh:

.. h

  • Oc~c:.ho..~e.

tJob'ble.. -sr'r.2-~~ ~+~or~ PL. PL.. PL. PL. p~ PL . p'" Pa..+ f>b C-4' Page Number ~+r4.C,").i:nt'!.Y1~i +~'*I<.~ I Allou.>o..bl~ St~~~. ~C:.\\ "':>o*i.~ ..i:,o.~?~ '=>1°z.1is Ot"i~ naJ ~"2..~* ~ I 215.q I . z.~.~ 1 Z.C5.CJI

Z~
  • at5 I Is ~"":. isi *1 E: ~

aJI. I 19* 01 \\~*O, lei. 01 'Z~.oC5 59*1~. 2.o *~O Z.'2.*2.2. -:.is.,b zo.oS 5'1*1~ S*'OJ I~. o I ~,*OZ 2.. e:> *oz:;,. 'Sl:f*i~. . 22*'$~ 2.1. ~~- 2..\\*~S ZE:, *OZ::, 5'9*ib 21 *12: z.c.~+ . ~CS.~b * '.Z e:>

  • Q t;).

~9*,~ ,~.Cf~.. l ~.~2. Zi *9 \\ l~*iO QJ?-,,,: ~1*~ 10*2.~ z6.f:>o 4~*~1 z.~. Q c:;,.. ~4l*1b I i I ---,.....*---****~'f'*~~....... l~~llf.'lt*~!?'C. ~* {P:.. :W

~~POWER Lls'L::J SYSTEMS COMBUSTION ENGINEERING. INC C-J Page Number e:,. pu.Yo'\\p ~u..pport~:

  • th4..

c~i~,..~ _-:,4.:~"":~ ~C'.c.~4ra..+:onc::, u<<:i~ < R..4f.i;,. C z,*cs, Cb Q"""c:l *c, ) +o ~C-4'.lo...t4. +h..o.... S~E. I oo..d."=>.for th4.. ru."rY\\p ~u.ppor-t~ c..c).A.r.Q.. OcZ.~ hori6°'"t~ll~ ~Y1d _O*I~~~ V=-'t't-i CA..tl ~ * "i.'nA. ~J :+;o""Q...\\ pv...~ p -;,~poY-t \\ oo...d~ d1.14. +a

  • o..c..c..cl.c..~a..f;oY\\C-, of,..,., ~ her i6a-..,+o..1 C\\'V\\cl c *~4-~

VQ.. V°f i c.a...I o.. c; r ~~ h-i W\\.A."" cl~ b ~ ~f. C l. v..}Q..Y"Q...

  • c:.c.J c.&Jaf-~
  • b~ th4.. fo\\\\oc.U~"r'\\~

~J~+:o'f\\~ ~ _4 fe!-1

R.' ( '. ~,,, -

I%.~ ) = z:;_, ~~ R.. I

  • ~~-

. '*i-.,,,~~):: .t0/Z.2 - /2..2 (

    • ~~~

l*5bR.2. wh~r4.. ~. Ot"'l"\\d R., ~r.o.. fc.LYYlf -::.u.p po..-;- loo.&5 dcJ.Q. *+o \\r~~+:"A!~ 'z~ ho"'.': 0 o.;...~l ~c:.ca.J.Q.~:o\\-. c;\\Yoicl ~ l ~~ ~ '/A.r-t: c:.o..\\

  • o.c.CA.lA.t-cdi on, ~

Atro.dn*"f'l'l..""n+ JI. fo'r or:4."'l'\\To..iio\\i a..,..d Aft~n'n'lc.V\\t Ji!< E:ndosur~ Z~ T~l~.\\ cf.;.o.f. CZ) foY- ~~~:_i-LJ.d4.':), 4 it 1 QY\\c{ 0~*2 ~:r..ci. ~ J:;.; o~a.J P"._°t\\? ~i;.ppol"'t lao..&t~

  • di.t..o.. to th.:.. cl1'f{.:.r.4..;1c.(2. o~ TuQ.. <::>~'1Smic.

o..c:c 0J4 ~t; Oi'\\S of r~ '$ rQ. ct,* ~r ~ c l * 't.I ~ -.* z ~ ') h o't";a-o~ta,j O.'"f\\d Ca ~4-~ -

  • I~~ i) V~Y't-: Ca.-1 *
  • B~ ~c.J:>~+:+u.+:'""'~ vo...I U.4...~ c+

A+t-C\\.. ch YY\\Q.'V'\\t :r:r. ~+o +n~. o..bo\\/(?. ...:..~ l.la..i-:oY\\~ _ i*h a.. o....dd,'+io'f"lo.-1 \\ o o,..e.l~.for ~C\\., FZ-c:. O.Y\\ct f?..b a..'("Q. ob*f*o.4-n"A *Cl.~ ~hoi.vn '\\'Y'\\ lo..'ble.. JI.

Luc., u. I L;.. u <;:> it. z Luc:,*~ ~ LUC:, u 4 ..of!_ .6~0. .oRb A Re .4 Ro. 4~b 4~e.0 R.a.. Afl..b .6 F?.c: A~ AR.ob A~ "5 *~c:iR1 -J: ~4

!:~~*

i.?4 + ~21 +/- t:;)4 +/-54 1--- -- I *S6 Rz.

l:<t*4

,+/-q.4 +/-Ci*4 +/-1*& S*~S~1 +/ :t 54 +/-z.b.& +/-.':>4 'T26*& :t '54-Note. : All \\co.A~ *li~+-.-ul o..bove. o..r~ o.a;~ll.W\\: ""~ o..ct: V\\~ ~ +h4. c:..G-..1fA.\\'" of ":1LA.fpo~t. poW.t O 1 'Sa.A. A~Ho..e..1~Q.."Y\\t ][. ~ IO... z c 3 ('\\ i" I

I I : I I. I 1 *. I l { j I _J. Jl.. + J f' ll... ~

+ -.

0 )> l II 0 j p - l ?j- ~- ~ -~ I> r ~

  • .J'

' -J! -*' 0 . f". . Cl .:0 I>. ~ 0 .o <lJ !:J (f- '..:-J ~ Ji -- t> ~ g J' ~ ~ Q z c 3 ' Sf.. ,.,~ I

I .. ~ : "!)c;.., ,AO~. W..\\"O.\\-\\A. l1 """ o H. : 'Z " "L - --O~v.J.oJ-WJ.,, -\\-"'-~\\.~oH *-: 'P ~~ cc::a b *; \\.A..o:+~-': 'f

) -vii+ w

~T"r'r o H v.o:~~ - -i-r I ~~ L-V\\ -- \\AC :+-nr--! r ""'O ~"1+ """"' e,,.,ripcr1 uo:+.,,,c; -

  • ~

,, ~ ' ~ 1 = l'!'T(')1 't:I -a-.A~ li \\)'t _ \\ ~ C\\Ci~r"°"SCZt..:Z* + ':>~v)+.,(t)~v ~lbtc:a* )) ~9L.oo ~ = "1 L, ~ L p~~ Sf -z.<..o~~~S~v-t">;iJ,.,.)+ 4 (11~Ci.~~~v;>] l: ~<;,. -:::>~ "7 '? l ~ o c

  • 4 q~ v ~.S,7.9 oo * + 'V~ v b'1-<<;.~o * ::

'c

  • -=-

i-c:.:. - CiJ ~ ~rx -:;"CjV -i- 0~~ ~~ *px~V + C1eJ~ ~~"'t9Ci::>1 + --o~v~L~-?oo, : )'l"""C"'>"' ~ . \\)~ ~ -::i. oS.Cc.~07;) qd""" -. 4 oS~ ~s ~""' = ~

~-4~ rfl7(">'1 "tr<;~ dw..,.. d - ~n,.

. ""44- +~ C,°'?1C.~T.)..fC:.. / t,:>*j-°OQ ~t? JI 4-V..~\\M~i-'o' "?,)"?r~ . 01-::J

>NI "0Nltl33Nl~3 NOusne...o:.

SIN3l.SAS g_;:ri** Ci3M0d~*

. *-*.6':..1.&.~_:....... ~~ .........-.1-.9......... ~"!.~.....,f!o*..............w,....-..:~::.1........ ~t.lll'C*a .... - * -~ - -:-*- --- ---~---- - - ----- -*-****-** --. ---*-*- - .... __ -:,.:-;.:._:... ~ ;_; ------...... ~*-...;.,;,::.:;.=:.=--=~ WJ."O. ~"4.~~0\\M "** C?}. : "l 'f'. : 1 p

,"(J-v

""'"~- ~-n1,.,roH "'o:.pi:r<;.

  • ,,~ ~-i.l = ~:

-O'"<J~...\\O~ c;-rif"'f'cH \\.\\.O~~-<;. "'ez.~ ~CCL : I~ -:. ~ L~ : J'T't'M \\I ~.J."'Cl-1 r" ~["?.t q'"'d"'~S~l.S* ~~?) +,,c..~~~rb1~*>] ~b.p10 * =* ~M. "t (4 to<::r~"Z'Sq~'1+~,,)+ -i_C 0~'zs~~?,1 "vi: C:.~ -1.* ~ I. ':>'(§v -z~c;a-po * *+ q"9 CZ "t. -z.ro, ;. -o(f O? ~"Z.900, : ~~

  • ~
  • s~ C70? 'F')t,, ':>"2! v* ~-0 s~ ~°' Ip)\\ -0.CJ? + :;.~. = Cd+ ':l<:;

'fl"O"~ 'o' ~"vi o~C.Z C70J t\\a v + 0 s~ ~s 5-av = ~c;

-C-.J.-0 f't"?'"~ 'trC)~ dwt..,., d - ), ("\\,.;li4-

~~ C;it~~ ll-:J

lNI '!)Nll:l33Nl!)N3 N0USt'l91'10~

S~\\131.SAS ~* 83M0d~*

~POV./ER ~-~LS SYSTEMS CQMBUSTION ENGINEERING. INC C4> C-12 Page Number .f roM E!a.t. C '9 * ~t.-tb:: ~i:. -t- .Af!a..xd1~tb 11 + Af!.c:.~dt. c::.o~1~ CI ~'i.. ~- .""C;I. _1* _I

1"

. ~. = Co\\z.

. ~+ \\.,., c, -c-..J. ,,.1+f. c;, + c;, ~ t /\\ \\ ""ti"I er' -L

  • (. u..o !+--o.J."'(5\\ "t>=>:n:> F
+-"~/\\ 'b~~ I I

-p\\A.'O v..o :~~~:>~"O r+\\(.~. ..1.04 ~~I) L* f'\\Nt:I CJ* I *:Z. ~1~ j-0 "e~o~~ o.+ '!tr -e1cro.J.. -

  • ,.o

<;1'c;c;-...J.+<;. ~v.:pf"' <),q <),t"e-fi!+'"'OI\\..\\""21$.\\..1.0-:,, r-:r~~~qo -vq ~\\.M. '.. '..-1.0!-{.~~jj"'Q ~!¥<r/\\ ""114J.,.1,07 ~~~. }'\\l."O uo:~"'tl~::1:>~,~~o?,l.\\o'f ""'++..t. 0:J. 5't~*1) cs, \\A. 0!f!f1Ao-:J ~\\,4 !F0 I ';S~ ~!fl"t"J. -c..A""i)pw.ti ~~,...\\i"lo;. _"":s"'-t+ ~o.7 c;"b~c;."?)..i.+~ f"O"-f.r" ~1.A..!1.1..J.Tf\\Q.~ -uu..i.. -VI*~ c:ao*-z Lb* 99*~ -VL* bL*~ 27., 'Z,., qo*C:C I~* 1c;;*s- ~L.*Ci: ~* t~*~ o~.-z G>-b*~

  • cz1*z S~*

~*~ 'Z.Q*I ~~7..;.~~s.j =~~+'-'-;J ~ ~s~+~f='-"d Sc, ~~+c:; ~ -v~ Ci: ~ '2~.. I \\t

  • qN<i,r',

I c:; -:-4 I s ~Tl, d \\Mr'ld.J. o,;- C', 'd S~i>J+c;, :as~ \\-01..tO J+! ff\\7' : lt!. "aJcr'..L . DI '0\\9""0..L u:.. Urt"O'i<;, C,--o ~i:,- ~~ .J.o;:t c=:."S~a.J-tt; '3S~ rev.a !4 ~'Pf"'

  • x-ow "14+

""'.~et ~01 *..V: ~ 4~oJ.\\Ji~ I 1' ~.,.,.,.J.oj-SUO!ft:'""'g? ~C,-z,-~~. <:;,~o ~~o ;- ~\\...\\+ o+'-";4 J! -zrfr'..L j-o ~(Trirof\\ ~v..*+'l"lf !+~c:;ri<;

)NI "!)Nltl33Nl!)N3 Nousnerwo--

S~"'J3 J.S AS ~:, H3t/\\Od §_!-~

i l .1 ~ ~*, J .'J f I . To..b\\.ct. IV : Iha. ~oVQ.Yni'Y\\~ f~lhld ~+t'4-cr.,~c,, fo.. puvne, I~~ U"t'\\JA..,- _+hA. )"..Q.\\J;~ ':>~E loo.J:"~ ~~ Lu."!:> f'la. Pm, p~:wia..r~ l'Y\\A'mb~'"11.~+r-Cl't;>, fc:.~' c Pt., if

e. "). pn,...,""~!<.*tM""'bY'C'"l\\4. pl1.1~ ba.~di~ ~h1t~':>.~I R.a..faW12.nc.~-:i Ori~l ov\\o...I. Tobia..m To'h....'

G>dll AlloWclLIQ o.-:~ion~I 'To.bl~ :m. Ta+o..l CoJ.o. Alw.c))\\,!~ "' I 21-ro-f h

  • C2l

~o.f,.B, 2e.crz Z*I~ 2:.'3*o~ ~'5*<> ':2.>.4~ -~~*45 41*~ ' ' ~ z.. Zb*61 C2>. RQ.f, B:, .2Z*'1Z ~*1'3' 21~61 *... ?13.o S*2:>1 4o*~l 'f I*'?. (I "I C2> 'Ra.f. f:>S '>>P ~ 21* 'tS

  • z,42 2.4*~1 Z.1* b"l

~~.~ ~.1'1 ' ~6. Z.'\\ 41*~ $4- .( J > CZ) ZI* Z.=!> z.oe, z:~.~ I 2.1*61 ~'5*2. 4.14 ~'l*~1-41.5. l?.Q.f, Bb Not.Q. ~- froW\\ R.Q.f, 6 f'o Y. ~A- ~rsl <::>n>JA c..r f:>~ mo4-.a.r: a-\\: I li:.~I o .. <11 c:.o.d.A. tA.l\\owo..b\\D.. ~t'rQ.~<;. w: t*'5~W\\ : "t..1*_61 4"5CO F ca> Cod.a. oJlow~IA. ~t~4..~~: l*ISC' l*~~\\V\\): 41,1:5t:.~* @ ~~° F. ~ ~ () 3 \\ i"......... .. I\\) ~ n r.-"'(] I~ z ~ (/)"'O. £! -<O ~ U) -~ -i:E zmm ~ !::XJ fl (/) I/' I . I

~--------*

~PO\\VER

-~SYSTEMS

  • ASUST*ON ENGINEERING. INC c~13 Page Number
v. Ati-o..c...h YYI c. YI ts.

(I l p~..Q. ~ of R.Q.£ 4, ~+r~~ ":>U"M'WlO..~ -fer pi.1."rr'p C:a..';)e. fo'r ~~E. ~QJ.Q.r-o.:f';aY\\~ of.?.~ hc_..,.~6 0"11\\W Q""cl

  • l~~~ v~-rt:CA.J:

__ :G~o: _ -- c:.* EL~=-~-!~~~~~~y cmC~~~y- -~L:~:~>L:J Suction 1

  • l2S 25~912 PL 28,050

~ Nozzle 2

  • 129 21,i69
  • PL+ Pb+. Q Se,050

! 3 128 22,836 PL+ P0+ Q . SE.,050 I I

  • -**-*i Diffuser*

1 695 19,072 PL

  • 2s,oso..
2.

691 1:6,296. PL+ Pb+ Q 52.,050 i 3.. 691 19,595.

  • .. -PL+ Pl)+ Q SS,050 Vane

" I 1------,--------- --.--*-----------:- ~--* -.. ---*--* -... Suction 1 171/172 *

  • 20,503_

PL

  • 28,050 Nozzle. 2 171/172-30 1 583 FL+ Fb+ Q 58,050
  • Flanze/.
  • 3 171/172
  • 2~,855 PL+ I>b+ Q 5S 1 050 Volute I

1 --------.-------*-*----**-- Bolting

1 361/362..

5,808 . PL

  • 28,050 Flange/

2

  • 157/158 19,eGS PL+ Pb+ Q 58,050 I Volute Shel~ 3

. Sli/512 23,419. PL+. P0+ Q SS,050 1 l I r---- --1--------:-*---~- -*~ ----- -------*----*------ - -. -----1 !*Crotch , 1 83/8l:/ 22,532

  • PL 28,050 "J

85/SS I i Disch<!.r~e 1

  • Nozzle I

I

  • 2

.66/67 30,7:39 ?!.+Pb+ Q.. 58,050 .

  • 3 6S/69.
  • 33,557

. PL+ !'0+ Q 58,050 i t -*-**--~ - -- -. -*. -... I l 83/84/ 21, i20 i'L 28 1050 2 3 1 2 85/86 , I 83/e4/ 24,697 PL+ ?b+ Q 53,050

  • 85/86 83/f:.4/

85/Su 639/6!t0 639/640 25,.474 . 13,955 16,233 58,050 18,700 28,~SO * ,,_..,,-=---..-**--*--.....___._, ______,,......... .,_.~""',... .. ~. .p 2i4ip ...... ~ .... ~~.,...,..,.,........,__- -*-----~- - ----....-... -.._,w-.

-~PO\\VER ,§~SYSTEMS ~c1.1aUSTION ENCilNEE:!'l1N9. INC C-14

  • Page Number C2) p~4. Xi of R_Q.f. t5, ~+r:i-:i~ ~U)YW't'\\a..Y"!S f OT" PU. 'rV\\r CA.~Q.. f~'r s~e. a..c.c.~~Y"a..ti OY\\ of *CSSJ 'bo-th ho*r\\~o.,...fa..\\ er-nc\\ V4.ff :CA..\\):

---~------* -*------ -*sT*r.:r:ss ALl.Qt;.!.Ci.:: I REC!C~: Suction Nozzle Diffuser Vane 1 2 3 l 2 J 128 129 12$ 695 691. 691 - 25,912 21,769 22,836 19~072 16,296 19,598 CA.TECO~'! !>L + Pb + Q. PL+ Pb+~ 28,050 SS,050 58,050 28,050 SS,050 PL + Pb + Q - 53, 050 Sucti"oo. Nozzl~ Flange/ Volute l 2 3 121/122 319/32C 319/320 46,82S 42,263 itL +.Pb + q rL +Pb+ Q 28,050 58,05C 56,050 t------~-------------*--------------------------------------- Boltinz Flange/ Volute 1 2 3 361/362 511/512 5ll/512 16,007 36,591 58,050 i "3"5,314 53,050 .1--------------,----------*----------*----- Cror.c:h l 2 , 65/70 68/69 21,852 28,050 54,647 58,030 t-----*--*-3 _____

  • _6_s1_6_9 _____

1is_._s_o __ 4 ____ P_L_~ _i-_b_+_o_. __ s_s_, ~~~ _ 1 1 83/8~/S5/S5 26,340 PL 28,030 I t>isc:h~rg'!: 2 83/84/85/Z~ 31~84S PL+ ?b + Q 58,050 1 3 S3/S4/SS/3o 3~,9S~ PL+ rb + g SS,050 .1 651/ 65:? 18, 516 P~r 18, 7 00 i _________,2 _____ 6:_9/Gso __

26. 19..:___. _ __!j. _ _:: :§.. __ 3~_.os~-1 Noz:.le

~~,.,,.....?.. q,....,..,.__~--*--.---*-**-----*- --~ -..-----*---,..-* ______

      • ~--:- *.,-~*,*---":*:"'-~T" *:w---*.. ;-~-----~~*--*-**,..---.~-...-*::r*....,.. *~*

---..-.-""!-.....--..~-....-.--.. __,...., -*-'l"-T'f'*.-.....,_._,_-._...-'°'"'....,._

L~i.5 svsi-"E~1s COMBUSTION ENGINEERING. INC .~. =-*~

  • .-. - ~*._:*.*

... ~... ~*.\\ ** :1 ** C-15 Page Number I l~#*

.f-'=f-.=
::::~~

-,6. ---a.... I

  • \\\\-J
  • ~...._..,,.
    • .---~~-----------~---~----*------------.... --------------------------~-..... ----
z *~!:i' *.

~*

r.

I ~... ~..

-:.. :...,... ~-..

~: r~~::~~. --~.... *... ,.. ::_:_:."z*..... ~~-:}: ': ;f-:,/~1~1~ 7'_.*: . ~-.: -~ *::;: ;/ .. :~ *:. * ... ~* *.... =**

            • -**-**-A *-:**-:::.*

~- r ~~ ' ~*:, ::.*:.~~..:: ~... :. _...... _~:::: ":C*. 5 \\\\--._._ y*:. ~ ...-.*~ ~".**-t.

>N1 *o~ml33Nl'JN3 N011snon~-

S lfJ;J J..S AS ~

~~J2 PO\\VER ~l-5 SYSTEMS COMBUSTION ENGINEERING INC C-17 Page Number

c. Att~°r'l'\\4."l'\\t !JI: cY\\c..lO~~re.. 2.-lc..b\\..,, of R.Q.f. C2*

E",j"cto~Ht~ 2 - TA-eLe

  • , (Fo_.-1'""?'-.::i- \\A, ~A ~ $\\ ~, ~s )

Re..L* ~'~"tl Ot>:ra.t,;, Dc:s ~~'"\\ - -'. I

e.

~f<t?. st\\.rt-Ao....., Ev~o""*kce ~~~ t-:.i I'\\. 't,~_, U. af Ll.lt5 I* (x106 i~.) \\ 2 3 4 5 ~ 1 B ?t-Ra_. .u +/-0.0l 10.01 -..J . 'ti I-Ro i 0.07 -o.,4 +o - ro,o*} +/-0.06- -\\- '1 -o.lO A -.07 _o.ooo a ~ . R~ +/-0.0\\" +/-.o,ot tc"t ~ \\..,_

o.ot

~o.o l .3 ~ R~ 010~ '2 ~.04 .. ~ ~c.07 :!o.09} i=to,o !,. +/-0,00b . i-0.01 Q G Re ~ +/-o,o\\ ~o.ol ll. ~ .. rl1 ,,:(- p-4. ~o( +/-o.or .J ~ ~ R~ !:to,o~G +/-0,05* +/-.o,OD.2 to,04

?

i..o, \\{; A 0 f, <f R, +/-.O,o(

  • I-.o'

.ll ~--r Ra. ~o,Ol ~o.or .. 'r ..l '= ,\\ R~ +0,04 -o.' t ~o.oo}. ~-;0104- . ~O,Obj. 10.05

z

. o.~j.:. 11 . F. Re. +/-0.0\\~ +/-o,O\\ cl.

/ - / 0 Enclocurc ~ PA G,*£ (2-11!3 I LOAD T,*J3L~S DEXRIPl'N~ ?ial'ES TA:'5L~ l - Lists t~e loads acti:ce; o~ the p::::; lues as*s~o-.r.i in sketc.bes 1 nn:l 2. 'IC.ese *leads e:-e c.~e to Il:>r--al o~retiro.::;, ccs!g.c ea.rt'!:::.qti.ar.e end sa.fe s?:titdo-.'n ear+...!:;_\\Ulk'!? c:o::.il tio::.s res:pectivel.;r. n:e referez:ce co.::>r:!!.cates arc tb.e a, b 1 c - exes. t:or-...tl

  • Cpt!r;iti:-...?; Co::d1 t1ons Col. 1 - Lists ~e ro~:es on the lt:.gs d~e to the dead ve1£bt of the ~--p plus that ~

of the ~l?C *-cight esti::!lted to 't:e e.c:i.."".o at this point. Col. 2 - Lists the loads due to thcr.:al Qxpa!lSion or the pipes. The UllllCr. ve.lues ~f"er to p-.:=pll lA e::d. 2.A, the lo.. *er val~es refer to p......~ lB *e.d. . a. lbsig:::i. F.art~c~::1:e Co=ditions. . Col. 3 *- T"z:e rec.ctioz::s* occur dt:.e to a desit:n ee:thqn:-~e e.eti~ alor.o the*---~; c:da. 'The ~ecel~ration used w.s obt~d 1'rc::J. the I'?~ vc.lu~ o.r ~e s~ctn::: c:ur-1c due to 0.1 s grcr.u:.:i c.:celer~t1on vit!l ~-or critic~ -..... -**--. f!.. ~!:o-(Si.i.,:-;.:.:'t.* o:-~ c;;.*-eliled.steel str.ictu.:re ":.°1.th i'ricticr.,] co~ct1c:u.)

  • Co1* ~. - Tue re~ctio~ 1.\\!r.! c?l~d by Ill:'~ O.C67G ~

ecccl.er.:i.ticn. 1n ~e "b" nxi~ cllrCct1c::i. Ccl. 5 - ~~e ~~ctiC:l!J *":!re obta.iI:..~ c.-:"" es Col. 3 e::ccep~ t.~ eo.rt?:qn.. t*::- 1"0~ cpplicd.* cl.c=z the Den c.:d.s di~tio:i. -~ ~ Col. 6 - S::::::? r!!J Col. 3 ac:cpt O.23 -~ eccel.C::utio:i lo~re U::ed. The c~ rotio l.-a:J 5~. . !!ol* 8 * ~. ! cs Col~ 6 except ~ ea.rth<ir,"'>C! rc:::e:: vas e~ci alCl:3 tb "c*.c:is.

l. **

I e 1~ r- -""----+....:-+~Q~ / I I Lue:, it I P/-16 c-19

( .\\.. PA~E C.-20 I . *~* r' ~* "°*. -~- _: ___ -* ~..... --** . i f-------.--_.:..;: ______________ ~-----------.. -

I I. - s *'h '=1 t /2-V 39b'd

I,.

dO':> ~:'~VoNnC:I ~ a+ /

  • ~

' ) l .. ~

-ry' r I -t-Rc \\ ___ J \\ .\\ \\"" \\ \\ \\ r-~1 L' :: P/-1GE C..-22

ATIACHMENT 3 Reactor Internals Seismic Review As noted in the Reference, an update of' the original seismic analysis of the Reactor Vessel Internals has been perfonned using the same methodology utilized in the original analysis. This methodology-consisted of load development by the. equivalent - static method using a lumped mass and beam model. The input acceleration used is the acceleration of the reactor supports based on a peak horizontal ground acceleration of.2 g per the NUREG input noted in the Refer-ence. Vertical and horizontal accelerations were applied simultaneously. The design criteria used were those specified in Table 4-3 of the NUREG input noted in the Reference for the load combination of dead loads plus SSE load. All stresses were found to be less than the specified allowable values. The following su11111ary lists the stress margins calculated for the components of the reactor internals in the analysis reported in the Reference.

  • . The margin is defined as:

(l _ Calculated Stress ) X lOO% . Allowable Stress The listed stress margins.are the minimum margins occuring in the reactor internals. Components not listed have a margin equal to or greater than those reported for their component assembly

  • COMPONENT LOCATION MARGIN %

CSB (Core Support Barrel ) Upper Cylinder 95 CSB Guide Pin 72 CSB Snubber 67 LSS (Lower Support Structure) Beams 83 LSS Core Support Plate 92 Peripheral Bolts LSS Column Bolts 81 LSS*. Columns 86 UGS(Upper Guide Structure) Flange 74 UGS Control Rod Shroud 96 UGS Lug Bolts* 88. UGS Grid Beam 91}}