consumers Power company General Offices: 212 West Michigan Avenue, Jackson, Ml 49201 * (617) 788-0650 July 2, 1981 Director, Nuclear Reactor Regulation Att Mr Dennis M Crutchfield, Chief.

Operating Reactors Branch No 5 US Nuclear Regulatory Connnission Washington, DC 20555 DOCKET 50-255 - LICENSE DPR PALISADES PLANT - SEP TOPIC III-10.B, PUMP FLYWHEEL INTEGRITY By letter dated July 11, 1980, the.NRG issued for connnent a draft evaluation of SEP Topic III-10.B for the Palisades Plant.

Consumers Power Company has reviewed the May 15, 1981 revision and finds it acceptable with one exception.

In Section V.A, the evaluation states that the flywheel bore stress in 8300 psi at a pump speed of 900 RPM.

According to Consumers Power Company letter (RC Youngdahl to PA Morris, USAEC) dated February 1, 1971 and Question 14.1 Amendment 15 of Palisades FSAR, this value should be 7300 psi.

Robert A Vincent Staff Licensing Engineer CC Director, Region III, USNRC NRC Resident Inspector - Palisades Plant I

~fiz7070141 81070~-

r* I p

' ADOCK 050002~5

. FJQR


.. -"'t-~~~