Forwards IE Insp Rept 50-255/79-07 on 790430-0504 & 09-11.No Noncompliance Noted
ML18043A822
Person / Time
Site: Palisades Entergy icon.png
Issue date: 05/18/1979
From: Heishman R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Dewitt R
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
Shared Package
ML18043A823 List:
References
NUDOCS 7907180394
Download: ML18043A822 (2)


See also: IR 05000255/1979007

Text

~.

I I


- - -

UNITED STATES

NUCLEAR REGULATORY COMMISSION

REGION Ill

Docket No. 50-25~~~"7

Consumers Power Company

ATTN:

Mr. R. B. DeWitt

Manager of Nuclear

Plant Operations

212 West Michigan Avenue

Jackson, MI

49201

Gentlemen:

799 ROOSEVELT ROAD

GLEN ELLYN, ILLINOIS 60137

MAY 18 1979

CENTRAL F!LES

This refers to the inspection conducted by Messrs. B. L. Jorgensen

and G. C. Wright of this office on April 30-May 4 and May 9-11,

1979, of activities at the Palisades Nuclear Generating Plant autho-

rized by NRC Provisional Operating License No. DPR-20 and to the

discussion of our findings with Mr. Keiser and others of your staff

at the conclusion of the inspection .

The enclosed copy of our inspection report identifies areas examined

during the inspection.

Within these areas, the inspection consisted

of a selective examination of procedures and representative records,

observations, and interviews with personnel.

No items of noncompliance with NRC requirements were identified

during the course of this inspection.

In accordance with Section 2.790 of the NRC's "Rules of Practice,"

Part 2, Title 10, Code of Federal Regulations, a copy of this letter

and the enclosed inspection report will be placed in the NRC's

Public Document Room, except as follows.

If this report contains

information that you or your contractors believe to be proprietary,

you must apply in writing to this office, within twenty days of your

receipt of this letter, to withhold such information from public

disclosure.

The application must include a full statement of the

reasons for which the information is considered proprietary, and

should be prepared so that proprietary information identified in the

application is contained in an enclosure to the application.

790'7180 '39t; 4/

J

........ ,::: ""

!"

...... ,1 ..... jp

  • .~ .. t._ ~ ""*. *" ..

a

Consumers Power Company

- 2 -

MAY 1 8 1979

We will gladly discuss any questions you have concerning this

inspection.

Enclosure:

IE Inspection

Report No. 50-255/79-07

cc w/encl:

Mr. J. G. Lewis, Plant

Superintendent

Central Files

Reproduction Unit NRC 20b

PDR

Local PDR

NSIC

TIC

Ronald Callen, Michigan Public

Service Commission

Myron M. Cherry, Chicago

RIII

RIII

,wi

tu!.

/'--Jorgensen/bk ~Warnick

5/17/79

Sincerely,

R. F. Heishman, Chief

Reactor Operations and