ML18038B657

From kanterella
Jump to navigation Jump to search
Forwards LER 50-296/96-01 Re Reactor Scram Due to Faulty electro-hydraulic Control Frequency/Voltage Converter Card. TVA Plans to Send Faulty Card to Vendor for Further Investigation
Date released: 09/27/2018 Download: ML18038B657


LER 96-001-00:on 960229,reactor Scrammed After APRM High Flux Scram Signal Because of Partial Closure of Turbine Control Valves Due to Faulty EHC Frequency/Voltage Converter Card.Main Turbine Manually Tripped & Faulty Card Replaced
ML18038B658
Person / Time
Site: Browns Ferry 
Issue date: 03/26/1996
From: Jay Wallace
TENNESSEE VALLEY AUTHORITY
To:
References
Download: ML18038B658 (14)
Forwards LER 50-296/96-01 Re Reactor Scram Due to Faulty electro-hydraulic Control Frequency/Voltage Converter Card. TVA Plans to Send Faulty Card to Vendor for Further Investigation
ML18038B656
Person / Time
Site: Browns Ferry 
Issue date: 03/26/1996
From: Machon R
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
Download: ML18038B656 (6)