ACCELERATED DI&IBUTION DEMONSTRKON SYSTEM REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

\\

ACCESSION NBR:8805260293 DOC.DATE: 88/05/23 NOTARIZED: NO DOCKET I FACIL:50-259 Browns Ferry Nuclear Power Station, Unit 1, Tennessee 05000259 50-260 Browns Ferry Nuclear Power Station, Unit 2, Tennessee 05000260 50-296 Browns Ferry Nuclear Power Station, Unit 3, Tennessee 05000296 AUTH.NAME AUTHOR AFFXLIATION GRIDLEY,R.

Tennessee Valley Authority RECIP.NAME RECIPIENT AFFXLIATION Document Control Branch (Document Control Desk)

SUBJECT:

Forwards addi info re inoperable radioactive effluent instruments

& updates corrective action program.

DISTRIBUTION CODE:

IE48D COPIES RECEIVED:LTR (

ENCL 2 SIZE:

TITLE: 50.36a(a)(2)

Semiannual Effluent Release Reports NOTES:G.Zech 3

B.D.Liaw, G.Zech 3

B.D.Liaw, G.Zech 3

B.D.Liaw, cy.

1 cy.

ea to: Ebneter,Axelrad,S.Richardson K.Barr, OI.

cy.

1 cy.

ea to: Ebneter,Axelrad,S.Richardson, K.Barr, OI.

cy.

1 cy.

ea to: Ebneter,Axelrad,S.Richardson, K.Barr, OI.

05000259 S 05000260/

05000296'ECIPIENT ID CODE/NAME JAMERSON,C MORAN,D INTERNAL: ACRS AEOD/DSP/TPAB NRR/DEST/PSB 8D

+RMA ILRB12 G F 01 2/DRSS/EPRPB EXTERNAL: BNL TICHLER,J03 NRC PDR NOTES'OPXES LTTR ENCL 1

0 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

9 9

RECIPXENT ID CODE/NAME PD GEARS,G AEOD/DOA ARM TECH ADV NRR/DREP/RPB 10 NUDOCS-ABSTRACT RGN2 FILE 02 LPDR COPIES LTTR ENCL 5

5 1

1 1

1 1

1 4

4 1

1 1

1 1

1 D'

D D

TOTAL NUMBER OF COPIES REQUIRED:

LTTR 34 ENCL 33

t t

TENNESSEE VALLEYAUTHORITY CHATTANOOGA. TENNESSEE 37401 5N 157B Lookout Place U.S. Nuclear Regulatory Commission ATTN:

Document Control Desk washington, D.C.

205SS Gentlemen:

In the Matter of Tennessee Valley Authority Docket Nos. 50-259 50-260 50-296 BROWNS FERRY NUCLEAR PLANT (BFN) INOPERABLE RADIOACTIVE EFFLUENT INSTRUMENTS In TVA's letter dated August 28, 1987 to NRC concerning the "BFN Semiannual Radioactive Effluent Release Report January to June 1987," TVA provided information on corrective actions to restore to operable status certain radioactive effluent instruments.

In TVA's letter dated March 1, 1988, to NRC concerning the "BFN Semiannual Radioactive Effluent Release Report July to December 1987," TVA provided updated information on radioactive effluent instrument operabilities.

TVA did not complete the corrective action as

'rovided in the August 28, 1987 letter because of delays in resolving various

design, maintenance, and procedural problems.

Enclosure 1 provides detailed information on which instruments were inoperable and our updated corrective action program.

Enclosure 2 provides a list of commitments contained in this letter.

In a preliminary conversation between Al Ignatonis (NRC Region II) and Joe Savage (TVA-BFN), NRC was informed that TVA would be providing a letter updating the corrective actions to restore the instruments to operable status.

Please refer questions regarding this submittal to P. P. Carier, Manager of Regulatory Licensing at (205) 729-2689.

Very truly yours, TENNESSEE V

LEY AUTHORITY R.

ridley, rector, Nuclear Licensing and Regulatory Affairs Enclosures cc:

See page 2

8805260293 880523 PDR ADOCK 05000259 p.

DCD An Equal Opportunity Employer

J

I hi J

'I J

k

U.S. Nuclear Regulatory Commission cc (Enclosures):

Hr. K. P. Barr, Acting Assistant Director for Inspection Programs TVA Projects Division U.S. Nuclear Regulatory Commission Region II 101 Harietta Street, NM, Suite 2900 Atlanta, Georgia 30323 Hr. G.

G. Zech, Assistant Director for Projects TVA Projects Division U.S. Nuclear Regulatory Commission One Mhite Flint, North 11555 Rockville Pike Rockville, Haryland 20852 Browns Ferry Resident Inspector Browns Ferry Nuclear Plant Route 12, P.O.

Box 637

Athens, Alabama 35611

t t

A It I

t

~

W I I

')~A g

It W, IJ I

W I

I' WA,I It II A'I

ENCLOSURE 1

The following is a list of inoperable radioactive effluent instruments as originally provided in an August 28, 1987 letter from R. Gridley to NRC concerning the "BFN Semiannual Radioactive Effluent Release Report January to June 1987."

This information was updated as to operability status in a Harch 1, 1988 letter from R. Gridley to NRC concerning the "BFN-Semiannual Radioactive Effluent Release Report July to December 1987."

The following list also includes the return to service dates as provided in the August 28, 1987 letter and our updated information on operability dates.

Instrument 1.

RHR service water monitor 1-90-133 Ori inal Date 3/31/88 Revised Date 8/31/88 2.

RHR service water monitor 1-90-134 3/31/88 8/31/88 3.

RHR service water monitor 2-90-133 3/31/88 8/31/88 4.

RHR service water monitor 2-90-134 3/31/88 8/31/88 5.

RHR service water monitor 3-90-133 3/31/88 8/31/88 6.

RHR service water monitor 3-90-134 3/31/88 8/31/88 7.

Raw cooling water monitor 1-90-132 3/31/88 8/31/88 8.

Raw cooling water monitor 2-90-132 3/31/88 8/31/88 9.

Raw cooling water monitor 3-90-132 3/31/88 8/31/88

10. Liquid radwaste discharge monitor 0-90-130 11/30/87 6/30/88 ll. Liquid radwaste discharge monitor flow rate loop 77-60 10/31/87 6/30/88
12. Stack effluent flow meter 90-271
13. Stack effluent monitor 90-147A 9/30/87 9/30/87 9/30/88 8/31/88

Instrument

14. Stack effluent monitor 90-147B Ori inal Date 9/30/87 Revised Date 8/31/88
15. Posttreatment noble gas monitor 1-90-265 9/30/87 5/5/88
16. Posttreatment noble gas monitor 1-90-266 9/30/87 5/5/88
17. Fosttreatment noble gas monitor 2-90-265 8/87 5/5/88
18. Posttreatment noble gas monitor 2-90-266 8/87 5/5/88
19. Posttreatment noble gas monitor 3-90-265 9/30/87 5/5/88
20. Posttreatment noble gas monitor 3-90-266 9/30/87 5/5/88

ENCLOSURE 2

1.

RHR service water monitors (1-90-133, 1-90-134, 2-90-133, 2-90-134, 3-90-133, 3-90-134) and raw cooling water monitors (1-90-132, 2-90-132, 3-90-132) will be operable by August 31, 1988.

2.

The liquid radwaste effluent monitor (0-90-130) shall be operable by June 30, 1988.

The flow rate loop,(77-60) will be fully calibrated and operable by June 30, 1988.

3.

The stack noble gas monitors (90-147A and 90-147B) will be operable by August 31, 1988, and the stack flow meter (90-271) will be operable by September 30, 1988.