REGULA RY INFORMATION DISTRIBUTIO SYSTEM (RIDS)

SUBJECT:

Forwards info re SEH Outstanding Issue 67iuse of nonsafety grade equipment in shaft seizure accidents DISTRIBUTION CODE:

8001S COPIES RECEIVED:LTR ENCL TITLE: PSAH/FSAR AI4lDTS and Related Correspondence SIZE:

NOTES:Send ILE 3 copies FSAR 5 al 1

amends

~ 1 cy.'BWR LHG PM(L.RIB) 05000387 Send ILE 3 copies FSAR 8 al 1

amends 1

cy:BwR LHG PM(L,RIB) 05000388 ACCESSION NOR:8105190174 OOC ~ DATE: 81/05/15 NOTAR1ZED:

NO DOCKET' FACIL:50-387 Susquehanna Steam Electric Station< Unit 1< Pennsylva 05000387 50-380 Susquehanna Steam Electrtc Stationr Unit 2, Pennsylva 05~

AUTH FRAME AUTHOR AFFILIATION CURTIS'

~ W ~

Pennsylvania Power 5 Light Co ~

REC IP ~ NAME RECIP IhN I AFF ILIATION YOUNGBLOOOEB.J ~

Licensing Branch 1

HECIP IENT Il) CODE/NAME ACTION:

A/I) LICENSNG HUSHUROOKEM ~

INTERNAL: ACCID EVAL BR26 CHt.M ENG BH 05 COHE PEHF BR 10 EjUIc,RG PREP 2d GEUSCIENCES 14 HYU/GEO BR 15

I8h, 06 LIC QUAL BR ME('H EIVG BR lo NRC PDR 02 OP LIC HR PROC/TST HEV 20 R

~

'H22 01 STT~UCT ENG BR2b COPIES LTTR ENCL 1

0 1

0 1

1 1

1 1

1 1

0 1.,

1 2

3 3

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 RECIPIENT ID CODE. /NAME LIC BR

~2 BC

STARKER, 04 AUX SYS BH 07 CONT SYS BR 09 EFF TR SYS BR12 EQUIP QUAL BR13 HUM FACT ENG BR ILC SYS BR 16 LIC GUIO BR MATI ENG BR 17 MPA OELD POWER SYS BH 19 QA BR 21 REAC SYS BR 23 SIT ANAL BR 24 COPIES LTTR'NCL 1

0 1

1 1

1, 1

1 1

1 3

1 1

1 1

1 1

1 1

1 0

1 0

1 1

1 1

1 1

1 1

EXTERNAL: ACHS NSJC 27 0>

16 16 1

1 LPOR 03 1

1 gpss 8i]9M

~I T0TAL NUNUER QF coPIEs NEUUAREo:

LTTR Pf EiiicL

/el

TWO NORTH NINTH STREET, ALLENTOWN, PA.

18101 PHONE: (215) 821-5151 NORMAN W. CURTIS Vice President Engineering & Construction 821-5381 May 15, 1981

~ ~

Mr. B. J. Youngblood, Chief Licensing Branch No.

1 U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Docket Nos.

50-387 50-388 SUSQUEHANNA STEAM ELECTRIC STATION SER OUTSTANDING ISSUE 67 ER 100450 PILE 841-2 PLA-783

Dear Mr. Youngblood:

Attached is a discussion on the use of nonsafety-grade equipment in the shaft seizure accident.

This discussion completes our action on SER Outstanding Issue 67.

Very truly

ours, N.

W. Curtis Vice President-Engineering and Construction-Nuclear GTC/mks Attachment cc:

R.

M. Stark NRC

'goo/

Si/

8~08190(7q T

P ~ NNEYLYANIA POWER E

LIGHT COMPANY

SUS UEHANNA-RESPONSE TO SER OPEN ITEM 67 USE OF NONSAFETY-GRADE E UIPHENT IN THE SHAFT SEIZURE. ACCIDENT The recirculation pump seizure event is considered to be an extremely unlikely event and as such falls into the category generally classified as an accident.

The event is evaluated as a limiting fault.

The potential effects of the hypothetical pump seizur~ "accident" are very conservatively bounded by the effects of the DBA-LOCA.

This is <<asi ly verified by comparison of the two events.

In both accidents, the recirculation driving-loop flow decreases extremely rapidly.

In the case of seizure, stoppage of the pump occurs; for the DBA-LOCA, the severance of the line has a similar, but more rapid and severe influence.

Following a pump seizure event, water level is maintained, the core remains submerged, and this provides a continuous core cooling mechansim.

However, for the DBA-LOCA complete flow stoppage occurs and water level decreases due to loss of coolant, thus resulting in uncovery of the reactor core and-subsequent overheating of the fuel-rod cladding.

Also,

- complete depressurization occurs, with the DBA-LOCA, while reactor pressure does not significantly decrease for the pump seizure event.

Cleal ly, the increased temperature of the fuel cladding and the reduced reactor pressure for the DBA-LOCA both combine to yield a much more severe stress and potential for cladding perforation for the DBA-LOCA than for the pump seizure.

Therefore, it is concluded that the potential effects of the hypothetical pump seizure accident are very conservatively bounded by the effects of the DBA-LOCA and a specific core performance analysis or radiological evaluation is not considered necessary.

However, to be completely responsive to the NRC question, the following narrative is provided to show the impact of not taking credit for non-safety grade equipment to terminate this event.

)

L l~Tbi Ti The FSAR analysis of the pump seizure event'ssumes that the vessel water level swell due to pump seizure will cause high water level (Level 8) trips of the main turbine and the feedwater

pumps, and indirectly initiates a reactor scram as a result of the turbine trip.

The FSAR (Subsection 15.3. 1.2.3.2 referenced by Subsection 15.3.3.2.3) discusses the Level 8 trip function and shows that a.

turbine trip will eventually occur even in the event of failure of the non-single-failure proof turbine"trip-signal circuitry.

In the case of the pump seiz'ure without an L8 trip, the event is less severe than the analysis in the FSAR with the LB trip for the following reason:

A pump seizure, should it occur, would result in core flow reduction which reduces the core power and surface heat flux due to the effect of the negative void reactivity coefficient.

Hence, the surface heat flux existing when the turbine trip occurs is lower because the turbine trip occurs. later.

Therefore, a loss of Level 8 trip would result in a less severe event consequence fl.om a fuel'standpoint than that depicted in Subsection 15.3. 1.2.

Page 1 of 2

2)

Hain Turbine B

ass S stem As a result of the NRC'q concern respecting reactivity effects of pressure transients, GE and the NRC met on November 20 and 21, 1978

. for a comprehensive review of turbine trip and load reject transients without bypass.

The principal conclusion of that meeting was that the most limiting BMR transient event which takes credit for nonsafety grade equipment is the feedwater controller.failure.

Analysis indicates that a bCPR increase of approximately 0.08 applies to this transient without a functioning main turbine bypass system.

For recirculation pump seizure with a failure of turbine bypass

system, the increase of DCPR would be less than that for the feedwater controller failure for the following reason.

As this event occurs, the reactor power drops significantly within the first 2 seconds due to decreased core flow.

Therefore, by the time of turbine trip, the reactor power is at a low level.

The core power is the main parameter which relates to the fuel thermal limit.

The effect of failure. of the main turbine bypass system to stop the steam flow retains pressure on the core but contributes only a small positive reactivity feedback.

This is a secondary effect of much less significance than the reactivity decrease due to fluid flow decreasing through the core.

This increase of core power is more severe for.

feedwater controller failure (increasing) event than for a recircu-'ation pump fai lure because it occurs at a higher power level.

3)

Relief Function of Safet /Relief Valves The contribution of MCPR from taking credit for the relief function rather than the safety function of safety/relief valves is not significant because the MCPR always reaches its lowest value before opening of the relief valves.

O Analyses of recirculation p

mp seizure where coolant flow rate drops rapidly have shown that. MCPR does not increase significantly before fuel surface heat flux begins dropping enough to restore greater thermal margins as the plant 'intrinsically responds to the reduced flow rate.

The effect of not taking credit for non-safety grade equipment is a bCPR increase of 0 F 08.

Page 2 of 2