Text

COL Carolina Power &Light Company R O. Box 1551

~ Raleigh, N. C. 27602 ggN 1 2 1989 R. B. RICHEY, Manager Nuclear Sewices Department SVQi240599 8'at'Qi i2 PDR ADOCK 05000400 9

PDR SERIAL:

NLS-89-008 10CFR50.55a United States Nuclear Regulatory Commission ATTENTION: Document Control Desk Washington, DC 20555 SHEARON HARRIS NUCLEAR POWER PLANT DOCKET NO. 50-400/LICENSE NO. NPF-63 IN-SERVICE INSPECTION REPORT Gentlemen:

In accordance with the reporting requirements of the ASME Boiler and Pressure Vessel

Code,Section XI, Article IWA-6220(b), Carolina Power Light Company (CP&L) hereby submits Shearon Harris Nuclear Power Plant (SHNPP), In-Service Inspection results.

The enclosed report covers the inspections performed during the first of two scheduled plant refueling outages in the first period of the first inspection interval.

Please refer any questions regarding this submittal to Mr. Steven D.

Chaplin at (919) 836-6623.

Yours very truly, R. B. Richey RBR/lmr(gcorgisi)

Enclosure cc:

Mr. R. A. Becker Mr. W. H. Bradford Mr. M. L. Ernst

,4 pp I'

w n

E E