REGULA INFORMATION DISTRIBUTIO YSTEM (RIDS) k ACCESSION NBR: 8802030018 DOC. DATE: 88/01/22 NOTARIZED:
YES FACIL: 50-400 Shearon Harv is Nuclear Poeer Planti Unit ii Carolina AUTH. NAME AUTHOR AFFILIATION EURYi L. W.
Carolina Pacer 5 Light Co.
REC IP. NAME REClPIENT AFFILIATION GRACEi J. N.
Region 2i Ofc of the Director DOCKET 05000400
SUBJECT:
Responds to 871106 NRC Compliance Bulletin 87-002'Fastener Testing to Determine Conf ov mance 4I/Applicable Natls Specs.
Thirty-six of 38 fasteners tested met applicable ASTM specs.
DISTRIBUTION CODE:
IE11D COPIES RECEIVED: LTR ~ ENCL SIZE:
TITLE: Bulletin Response (50 DKT)
NOTES: Applica ion fov pevmit renewal filed.
05000400 RECIPIENT ID Cynic ivhqE PD2-1 LA BUCKLEY B INTERNAL: AEOD/DOA AEOD/DSP/TPAB NRR/DEST/ADS NRR/DOEA/EAB NRR/
P/EPB
- ILE, 02 E
Oi EXTERNAL:
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 RECIPIENT ID CODE/NAME PD2-1 PD AEOD/DSP NRR/DEBT/ADE NRR/DEST/MEB NRR/DOEA/GCB NRR/PMAS/ ILRB RES/DE/EIB NRC PDR COPIES LTTR ENCL 1
1 1
1 1
1 1
1 1
1 1
1 1
1 TOTAL NUMBER OF COPIES REQUIRED:
LTTR 19 ENCL 18
COLl Carolina Power 4 Ught Company P. O. Box t55t
~ Raleigh, N. C. 27602 SERIAL: NLS-88-007 JhH 92 $88 LYNN W. EURY Senior Vice President Operations Support Dr. J. Nelson Grace, Regional Administrator United States Nuclear Regulatory Commission 101 Marietta Street, NW Atlanta, GA 30303 SHEARON HARRIS NUCLEAR POWER PLANT DOCKET NO. 50-000/LICENSE NO. NPF-63 RESPONSE TO COMPLIANCE BULLETINNO. 87-02
Dear Dr. Grace:
cP
~ ~
Carolina Power k Light Company (CPRL) hereby submits information requested by NRC Compliance BulletinWo. 87-02, Fastener Testing to Determine Conformance with Applicable Material Specifications," dated November 6, 1987.
The subject bulletin required that licensees review fastener receipt inspection requirements and internal controls, the testing of a sampling of fasteners to determine if required specifications are met, and a safety significance evaluation for those fasteners which did not meet applicable speci fications.
This letter provides the results of CPRLrs review and testing program and is submitted within the time frame as discussed with Mr. C. W. Hehl (NRC-Region II) on January 15, 1988.
The attached information is formatted such that the specific subheadings correspond to the bulletin item topics.
Thirty-six of the 38 fasteners tested met the applicable; ASTM specifications.
The 2 fasteners not in complete compliance with their specifications were evaluated and determined to be acceptable for their intended use.
Should you have any questions regarding this submittal, please contact Mr. Arnold Schmich of my staff at (919) 836-8759.
Yours very truly, LWE/AWS/mss (5362AWS)
Attachments L. W. Eur L. W. Eury, having been first duly sworn, did depose and say that the information contained herein is true and correct to the best of his information, knowledge and belief; and the sources of his information are officers, employees, contractors, and agents of Carolina Power R Light Company.
My commission expires: I//P 7/8'9 cc:
Mr. B. C. Buckley Mr. G. F. Maxwell NRC Document Control Desk 88020300i8 880f~2 PDR ADQCK 05000400 PDR ary ea tllsstss~<Ig~
NOTARY:
PU8LIC: (,
aaeasasea4a ~+
RESPONSE TO NRC COMPLIANCE BULLETINNO. 87-02 The following sections provide specific detail for each of the Bulletin 87-02 action items:
Action 1:
Describe a) the characteristics currently examined during receipt inspection of fasteners (i.e., head markings for grade and manufacturer symbols, review of certified material test report or certificate of conformance), and b) internal controls utilized during storage and issuance from stock to ensure the appropriate use of fasteners.
CPRL Res onse Inspections are performed in accordance with applicable receipt inspection procedures (OQA-002, Receipt Inspection, and OQA-003, Material Verification). Specific inspection characteristics include dimensions as specified by purchase order, head markings as required by material specification and tolerances as specified by ANSI B18.2.1 for square and hex screws and bolts and ANSI B18.2.2 for square and hex nuts.
Vendor supplied documentation (i.e., certificates of compliance and certified material test reports) are reviewed for compliance to applicable purchase order and material specifications.
Additionally, nondestructive and destructive testing may be performed as described by OQA-003, Material Verification.
Procedures require that material control (stores) personnel receive, package, and store fasteners in accordance with the storage and maintenance sheet.
Storage levels are assigned by Engineering Technical Support personnel.
These storage levels are indicated on the storage and maintenance data sheets and the supply inventory system data base.
Prior to use of fasteners, procedures require that the equipment data base system (EDBS), technical manuals, supply inventory system (SIS),
consumables list, and procedures and drawings be reviewed for proper application of replacement parts. If the repair part or consumable (fastener) is not listed on the EDBS reference parts listing for that component, on the approved consumables list, on an approved procedure, or on the SIS screen for that application, an engineering evaluation must be performed on that part/consumable prior to its use.
Changes, including field revisions and equipment substitutions in safety-related systems, are subject to control measures commensurate with the constraints applied to the original design.
Changes are reviewed and approved by the organization that approved the original design or other responsible
,. organization.
In addition, the part used is identified by CPRL part number and the purchase order number for each installation package thus providing traceability to manufacturer's documents.
(5362AWS/bmc )
Select a minimum sample of ten (10) nonsafety related fasteners (studs, bolts, and/or cap screws) and ten (10) safety-related fasteners (studs, bolts, and/or cap screws) from current, in-use stock.
The sample is to be obtained by the licensee with the participation of an NRC inspector.
Fasteners procured to meet the following chemical and mechanical properties are of interest:
A-193 Grades B7, B8, and BV16; SAE J029 Grades 5 and 8; A-009; A-325 Types 1, 2, or 3; A-350 Grades BB, BC, BD; A-090; A-.320 LTM;A-307; A-563; or equivalent.
CPRL Res onse Refer to our response for Action 3.
For the selected sample of fasteners in Item 2, include a sample of typical nuts that would be used with each fastener (one-for-one).
In particular, nuts purchased to the chemical and mechanical specifications of A-190 are of interest.
CPRL Res onse A total of 38 nuts and bolts were sampled, 27 of which are safety-related.
The remaining 11 are "structural" nuts and bolts which are not used in plant systems.
Please note that SHNPP uses safety-related fasteners for any plant system and has no nonsafety classification for plant fasteners.
The sampling of the "structural" fasteners as SHNPP nonsafety related fasteners was concurred'with by the NRC inspector participating in the sampling activity.
Chemical testing shall be performed on all samples.
Mechanical testing shall be performed on each safety-related fastener.
Hardness testing shall be performed on each nut and nonsafety-related fastener.
Alltesting shall be performed by a laboratory which the licensee has qualified for this type of testing and appears on the licensee's approved vendor list.
Testing performed shall be done in accordance with the requirements of the fastener's specification, grade, and class, and the test shall evaluate the ultimate tensile strength, hardness, and chemical properties as required by the fastener's specification, grade, and class.
Each sample shall be tagged with the sample's ID number.
CPRL Res onse Mechanical testing of each safety-related fastener and hardness testing for each nut and nonsafety-related fastener samples was performed by CPRL's Metallurgy Laboratory which falls under CPRL's Corporate Quality Assurance Program and meets the qualifications necessary to perform the testing.
Per discussions with Mr. J. T. Conway (NRC) on November 18, 1987 and Mr. P. E. Fredrickson (NRC-Region II) on December 1, 1987, the NRC concurred with the use of the CPRL Metallurgy Laboratory.
Chemical testing of the samples was performed by National Spectrographic Laboratories which is on CPRL's approved vendor list.
(5362AWS/bmc)
The testing program was in accordance with ASTM-approved methods required by the fastener's specification, grade, and class.
Each sample was provided a unique identification number.
The results of all tests, together with supporting information, are to be reported to the NRC utilizing the format shown in Attachments 1 and 2 of this bulletin. Include the names and addresses of suppliers and manufacturers of safety-related fasteners and, to,the extent possible, of nonsafety related fasteners.
For any fastener found out of specification, provide an evaluation of the safety significance including consideration of the most limitingapplication.
CPRL Res onse Results of the CPRL Bulletin 87-02 testing are presented on Table 1, "SHNPP Fastener Testing Data Summary." Table 1 is formatted in the manner suggested by the bulletin. The fasteners are categorized by the applicable ASTM specification and are listed by their unique identification number assigned at the time of sampling.
Results which do not meet the applicable specification requirement are denoted by an asterisk (+).
Table 2 lists the fastener supplier and manufacturer names and addresses.
Two of the 38 SHNPP fasteners (Sample Nos. HNP-SA193-B8-25 and HNP-SA193-B8M-08) were deter mined to be out of compliance with their applicable ASTM specifications.
Sample No. HNP-SA193-B8-25%as procured as SA193, Grade B8 material without a class designation.
The material is a 1/2 inch by 13 thread threaded rod designated for use in a variety of safety-related system applications.
The CMTR received with this rod identified it as SA193, Grade B8, Class 1 material; however, testing done per the requirements of this bulletin identified it as Class 2 material.
Either class is acceptable for the CPRL applications of this rod since Class 2 is a higher strength material than Class I. This sample met the ASTM requirements for Class 2 except for hardness (a measured value of 37 Rockwell C scale versus a code allowable maximum of 35 Rockwell C). The difference between measured and allowable hardness is minimal and has no significant effect on the ability of the material to perform its safety-related function..This is supported by its higher strength Class 2 properties where Class 1 strength is acceptable.
Testing of sample No. HNP-SAI93-B8M-08 demonstrated that it meets its code requirements except for hardness.
The testing measured hardness as 20 Rockwell C scale versus the code allowable maximum of 96 Rockwell B scale.
(The ASTM standard indicates that a 96 Rockwell B scale is approximately equal to 17 Rockwell C scale although direct correlation is not recommended.)
This material is used in a variety of safety-related system applications; however, there are no applications where the increased hardness would significantly effect the ability of the material to perform its safety-related function. Therefore, it is CPRL's position that the fasteners are acceptable for use in safety-related applications, and no further actions are required regarding these fasteners.
(5362AWS/bmc)
Based on the results of the testing and review of current procedures, describe any further actions being taken to ensure that fasteners used in the plant meet the requisite specifications and requirements and that the operability of safety-related plant components is not affected.
CP&L Res onse Based on the results of CPRL's review and testing program, we believe that our receipt inspection and material handling programs are adequate and meet or exceed the applicable requirements.
No further actions are therefore considered to be necessary.
'(5362AWS/bmc)
NRC Compliance Bulletin No. 87-02 Table 1
SHNPP Fastener Testing Data Susssary MECHAHICAL ANALYSIS CHEMICAL ANALYSIS ID NUHBER HARDNESS RA Si Cr Ni Other ASTM A 193 Crl HNP-SA-193-B7-09 HNP-SA-193-Bl-12 HNP-SA-193-Bl-13 HNP-SA-193-87-14 HNP-SA-193"87-15 HNP-SA-193-87-16 HNP-SA-193-B7-17 N/R N/R N/R N/R N/R N/R N/R 146,000 136,500 143,250 144,000 135,400 157,200 141,800 132,500 124,000 132,500 132,000 119,000 105,000 125,000 50 00 60.00 60.00 60.00 60.00 60.00 60.00 32.00 21i00 39 F 00 42 F 00 22 F 00 16 F 00 17.00 0.440 0.420 0.380 0.410 0.390 0.400 0.420 0.88 0.75 0.90 0.87 0.97 0.90 0.82 0.018 0.012 0.012 0.008 0.020 0.015 0.019 Oi012 0.025 0.028 0.012 0.015 0.025 0.031 0.34 0.89 N/R 0.21 0,90 N/R 0.25 1.00 N/R
- n. 21 0 87 N/R 0.31 1.00 N/R 0.24 Oi96 N/R 0.24 0.96 N/R 0 ~ 17 0.19 0.20 0.18 0.21 0.20 0.21 HNP-SA-193-BS-06 HNP-SA-193-88-07 HNP-SA-193-BS-25 ASTM A 193 CRBS Rb 88 97,200 Rb 80 89~200
+Rc 37 142~000 53>000 84 F 00 54 F 000 80.00 102 '00 60.00 69,00 64 F 00 32 F 00 0.042 0.064 0.061 1.15 1.37 1.27 0.025 0.033 0.029 0.002 0.017 0.024 0.34 18.51 8.25 0.49 18i89 Bi65 0.50 19.45 Sill N/R N/R N/R HNP-SA-193-BBM-08 ASTM A 193
- Re 24 CrBSM 94~200 60 F 000 80.00 53,00 0.062 1.50 0.040 0'16 0.59 17.05 llew ll 2
12 ASTM A 194 Cr2H HNP-A-194-2H-01 HNP-SA-194-2H-02 HNP-A-194-2H-26 HNP-A-194-2H-27 HNP-SA-194-2H-28 HHP-SA-194-2H-29 HNP-SA-194-2H-30 HNP-A194-2H-36 Re 26 Rc'5 Rc 29 Re 27 Rc 34 Rc 27 Rc 25 Re 25 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 0.460 0.440 Oi440 0.430 0.480 0.440 0.450 0.440 N/R N/R N/R N/R N/R N/R N/R N/R 0.027 0,009 0.028 0.020 0.009 0.009 0.009 0.019 0,033 0.029 Oi010 0.016 0'26 0.026 0,030 0.017 N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R Page 1 of 3 (2456NEL/jm)
MRC Compliance Bulletin No. 87-02 Table 1
SHNPP Fastener Testing Data Summary MECHANICAL ANALYSIS CHEHICAL ANALYSIS ID NlMBER HARDNESS UTS ASTH A 194 Cr6 YS RA EL C
Hn P
S Si Cr Ni Ho Other HNP-SA-194-Cr6-04 HNP-SA-194-Cr6-31 HNP-SA-194-Cr6-32 HNP-SA-194-Cr6-33 Rc 23 Rc 24 Rc 25 Rc 23 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 (0+120 N/R2 N/R2 0.140 N/R2 N/R2 Oo150 N/R2 N/R2 Ool40 0.50 0.026 0.50 0.030 0+50 0.027 0'1 0.030 0.002 0.002 0.002 0.002 0.39 0,41 0.40 0.41 12.58 12.82 12.81 12.81 N/R N/R N/R N/R N/R N/R N/R N/R ASTH A 194 Crg HNP-Sh-194-Cr8-03 Rb 86 SAE J429 N/R2 N/R2 N/R2 N/R2 0+570 0.96 0.026 0 028 0 41 18.45 9.50 N/R HNP-SAE-J429-Cr5-10 HNP-SAE-J429<r5-11 HNP-SAE-J429-Cr5-34 HNP-SAE-J429-Cr5-35 HNP-SAE-J429<rS-37 HNP-SAE-J429Wr5"38 Rc 30 Rc 27 Rc 30 Rc 26 Rc 27 Rc 30 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 N/R2 0.310 0.400 0'10 0'60 0'50 0.350 N/R 0+015 N/R 0,018 N/R 0.014 N/R 0.025 N/R 0.024 N/R 0.026 0.011 0.013 0.012 0.011 0+012 0.024 N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R HNP-SA-453-Cr660-21 HNP-SA-453-Cr660-22 HNP-Sh-453-Cr660-23 HNP-Sh-453-Cr660-24 AS' 453 Cr660 HBN 313 156,000 112,500 40.00 25.00 0'46 0.13 0.007 0,004 0 12 14.56 24'7 I ~ 20 HBN 313 157,600 117>500 60.00 27.00 0.038 1 ~ 34 0.010
<0.001 HBN 331 162,000 121,000 60.00 25.00 0.048 0.09 0.007 0.003 0+58 14.13 24'8 I ~ 29 Ool2 14.56 24.47 1+22 HBN 322 162,600 116,500 40 F 00 25.00 0.020 1 ~ 18 0.010
<0,001 0.48 14'2 25.01
1 ~ 31 Ti 2.18 V
0.29 Ti 2.28 V
0.20 Ti 2.20 V
0.29 Ti 2.30 V
0.26 Al 0.16 8
0.006 Al 0.16 8
0.01 Al 0 ~ 17 B
0.007 Al 0.16 B
0 006 Page 2 of 3 (2456NEL/jm)
NRC Compliance Bulletin No. 87-02 Table 1
SHNPP Fastener Testing Data Summary MECHANICAL ANALYSIS CHEHICAL ANALYSIS ID NUMBER HARDNESS UTS ASTM A 564 Cr630 YS RA EL C
Mn P
S Si Cr Ni Ho Other HNP-SA-564-Cr630-18 HNP-SA-564-Cr630-19 HNP-SA-564-Cr630-20 Rc 34 Rc 37 Rc 37 155,800 153,000 165,600 165,000 159,800 159,800 60.00 20.00 60 F 00 19.00 60.00 17.00 0.044 0.46 0+033 0.41 0.039 0.47 0.019 0.017 0.61 15.96 4.34 0.014 0.024 0'5 16.18 4.35 0.036 0.024 0.54 16.03 4.41 N/R Cu 3.19 Cb+Ta 0.26 N/R Cu 3.48 Cb+Ta 0.26 N/R Cu 3.29 Cb+Ta 0.29 HNP-SAE-Cr5-05 SPECIFICATION UNKNOW-Rb 91 N/R2 N/R2 N/R2 N/R2 Oe094 0+39 0.005 0.050 N/D N/D N/D N/D OUT OF SPECIFICATION N/R:
NOT REQUIRED BY SPECIFICATION N/R2:
TESTINC NOT REQUIRED BY NRC BULLETIN 87-02 N/D:
NOT DETERMINED NOTEI UTS-ULTIMATE TENSIL STRENCTH, PSI) YS<<YIELD STRENGTH, PSI)
RA-Z REDUCTION OF AREA; EL-Z ELONGATION) C-CARBON, Mn-MANGANESE) P-PHOSPHOROUSI 8-SULFUR) Si-SILICON; Mo-MOLYBDENUM'rCHROMIUM'i-NICKEL)Ti-TITANIUH; Al-ALUMINUM;V VANADIUM; B-BORON) N-NITROCENI Cb-COLUMBIUM; Ta-TANTALUH Page 3 oE 3 (2456NEL/jm)
Table 2 SHNPP Fastener Supplier and Manufacturer Names and Addresses Fastener ID No.:
HNP-SA-190-2H-02 HNP-SA-190-GR8-03 HNP-SA-193-B8-06 HNP-SA-193-B7-09 HNP-SA-193-B7-16 HNP-SA-193-B7-17 HNP-SA-560-GR630-18 HNP-SA-560-GR630-19 HNP-SA-560-GR630-20 HNP-SA-193-B8-25 HNP-SA-190-2H-28 HNP-SA-190-2H-29 HNP-SA-190-2H-30 Supplier - Texas Bolt, P. O. Box 1211, Houston, Texas 77251 Manufacturer - Texas Bolt, P. O. Box 1211, Houston, Texas 77251 Fastener ID No.:
HNP-SA-190-GR6-00 HNP-SAE-GR5-05 HNP-SA-190-GR6-31 HNP-SA-190-GR6-32 HNP-SA-190-GR6-33 Supplier - Siemens Allis, Inc., 3203 Womans Club Drive, Raleigh, North Carolina 27612 Manufacturer - Cannot be determined Fastener ID No:
HNP-SA-193-B8-07 HNP-SA-193-B7-12 HNP-SA-193-B7-13 Supplier - Ronson Mfg. Inc., 1091E. 363rd St., Eastlake, Ohio 00090 Manufacturer - 3osyln Stainless Steels, P. O. Box 630, Fort Wayne, Indiana 06801 Fastener ID No.:
HNP-SA-193-B8M-08 Supplier - Ronson Mfg. Inc., 1091E. 363rd St., Eastlake, Ohio 00090 Manufacturer - Ronson Mfg. Co., 9933 Chillicothe Rd., Kirkland, Ohio 00090 Manufacturer - Al Tech Speciality Steel Corp., Willowbrook Ave., Dunkirk, NY 10008.--
Stock Mfg.
Fastener ID No.
HNP-SA-193-B7-10 Supplier - Ronson Mfg. Inc., 1091E. 363rd St., Eastlake, Ohio 00090 Manufacturer Ronson Mfg. Inc., 1091 E. 363rd StEastlake, Ohio 00090 (5362AWS/mss)
Fastener ID No.
HNP-SA-193-B7-15 HNP-SA-053-GR660-21 HNP-SA-053-GR660-22 HNP-SA-053-GR660-23 HNP-SA-053-GR660-20 Supplier - ARG Engineering Co., Inc., 0600 E. La Palma Avenue, Anaheim, CA 92906 Manufacturer ARG Engineering Co., Inc., 0600 E. La Palma Ave., Anaheim, CA 92906 Fastener ID No.
HNP-A-190-2H-01 HNP-SAE-3029-GR5-10 HNP-SAE-3029-GR5-11 HNP-A-190-2H-26 HNP-A-190-2H-27 HNP-3029-GR5-30 HNP-SAE-3029-GR5-35 HNP-A-190-2H-36 HNP-SAE-3029-GR5-37 HNP-SAE-J029-GR5-38 Supplier - Bowman Distribution, 31 Misty Morning Drive, Hilton Head Island, SC 29928 Manufacturer - Cannot be determined Original Bar Stock - Republic Steel - Cannot determine address Manufacturer - Earle M. 3orgensen Co., 1900 MitcheIl Blvd., Schaumburg, Illinois 60190 Original Bar Stock - Bliss dc Laughlin Steel, 281 East 155th St., Harvey, Illinois 60026 Manufacturer - Earle M. 3orgensen Co., P. O. Box 1900, Schaumburg, Illinois 60090 (5362Aws/mss )