ML18019A907

From kanterella
Jump to navigation Jump to search
Currie-1993 - TN5306 - FWS1993 Recovery Plan for American Harts -Tongue
ML18019A907
Person / Time
Site: Clinch River
Issue date: 09/15/1993
From: Currie R
US Dept of Interior, Fish & Wildlife Service
To:
Office of New Reactors
Fetter A
References
Download: ML18019A907 (37)


Text

RE COVERY PLAN American ha&s-tongue (Asplenium scolopendrium var. americanum)

(Synonym: Phyllitis scoloyendrium var. americana Amencan hart s-tongue fern)

U.S. Fish and 1 Wildlife Service

RECOVERY PLAN for American harts-tongue (Asplenium scolopendrium L. var.

americanum [Ferna]d]

Kartesz and Gandhi [Synonym:

Phyllitis scolopendrium (L.) Newman var. americana Fernald])

Prepared by Robert R. Currie Asheville Field Office U.S. Fish and Wildlife Service Asheville, North Carolina for Southeast Region U.S. Fish and Wildlife Service Atlanta, Georgia Approved:

Date:

Jam s W Pulliam,Jr Director U.S. K hand Wildlife ServiceV 4.

Recovery plans delineate reasonable actions which are believed to be required to recover and/or protect listed species.

Plans are published by the U.S. Fish and Wildlife Service, sometimes prepared with the assistance of recovery teams, contractors, State agencies, and others.

Objectives will be attained and any necessary funds made available subject to budgetary and other constraints affecting the parties involved, as well as the need to address other priorities.

Recovery plans do not necessarily represent the views nor the official positions or approval of any individuals or agencies involved in the plan formulation, other than the U.S. Fish and Wildlife Service.

They represent the official position of the U.S. Fish and Wildlife Service only after they have been signed by the Regional Director or Director as approved.

Approved recovery plans are subject to modification as dictated by new findings, changes in species status, and the completion of recovery tasks.

Literature citations should read as follows:

U.S. Fish and Wildlife Service.

1993.

American Harts-tongue Recovery Plan.

U.S. Fish and Wildlife Service, Atlanta, Georgia.

33 pp.

NOTE:

Figure 1 and the cover drawing are reproduced with the permission of the Biological Survey, New York State Museum,

Albany, New York.

Additional copies may be purchased from:

Fish and Wildlife Reference Service 5430 Grosvenor Lane, Suite 110

Bethesda, Maryland 20814 Phone:

301/492-6403 or 1 -800/582-3421 Fees for recovery plans vary, depending upon the number of pages.

EXECUTIVE

SUMMARY

Current Status:

Asplenium scolopendrium var. americanum is federally listed as a threatened species.

It is currently known from 21 locations in the United States (2 in Alabama, 1 in Tennessee, 6 in Michigan, and 12 in New York).

The species also occurs in Ontario, Canada.

Habitat Requirements and Limitinci Factors:

This rare fern is typically found growing in close association with dolomitic limestone.

In the southern part of its range it is found only in entrances to pit caves.

The entrance areas to these caves provide the humidity and moisture levels that are associated with the populations found at more northern latitudes.

It is threatened throughout most of its range by trampling, logging, and development within and near its habitat.

Recovery Ob.iective:

To delist the species.

Recovery Criteria:

American harts-tongue will be considered for delisting when there are at least 15 self-sustaining populations in the United States that are protected to such a degree that the species no longer qualifies for protection under the Endangered Species Act.

Actions Needed:

(1) Protect known populations; (2) conduct needed biological studies:

(3) implement management, if needed:

(4) protect genetic material and reestablish populations, if necessary: and (5) conduct enforcement and education programs and monitor recovery progress.

Costs ($1.OOOs):

(Does not include cost estimates for land acquisition, implementation of needed management, or reestablishment of extirpated populations.)

Year Need 1 Need 2 Need 3 Need 4 Need 5 Total 1994 30.0 70.0 5.0 13.2 5.0 123.2 1995 35.0 55.0 5.0 5.0 100.0 1996 20.0 55.0 5.0 5.0 85.0 1997 45.0 5.0 5.0 55.0 1998 5.0 5.0 10.0 TOTAL:

85.0 225.0 25.0 13.2 25.0 373.2 Date of Recovery:

Recovery should be achieved in 1999.

provided the funds are available and needed recovery activities have been accompl i shed.

TABLE OF CONTENTS Page PART I:

INTRODUCTION Background and Description Current Status and Distribution Life History and Habitat Requirements Current Threats RECOVERY Recovery Objectives Narrative Outline Literature Cited PART II:

PART III:

IMPLEMENTATION SCHEDULE PART IV:

1 1

3 6

8 10 10 11 16 19 LIST OF REVIEWERS 22

PART I INTRODUCTION BackQround and DescriDtion On July 14, 1989, the U.S.

Fish and Wildlife Service officially listed American harts-tongue (Asplenium scolopendrium L. var.

americanum [Fernald]

Kartesz and Gandhi [Synonym:

Phyllitis scolopendrium (L.) Newman var. americana Fernald]) as a threatened species (U.S. Fish and Wildlife Service 1989).

American harts-tongue (Figure 1) has evergreen strap-shaped fronds that are 5 to 17 inches long (12 to 42 centimeters [cm]).0.75 to 1.75 inches wide (2 to 4.5 cm). and auriculate (lobed) at their base.

The green petiole is 1 to 5 inches long (3 to 12 cm) and has cinnamon-colored scales.

The son (groups of spore-producing reproductive structures called sporangia) are linear in shape and occur on the underside of the blade portion of the frond.

The fronds arise in a cluster from a short, creeping rhizome covered with cinnamon-colored scales (Evans 1981.

Lellinger 1985).

A detailed description of the species is provided by Lellinger (1985).

Ferns recognized as belonging to the species Asp lenium scolopendrium (then referred to as Scolopendrium vulgare Smith) were first discovered in the United States in 1807, when Pursh found the species growing in central New York (Maxon 1900).

Asp lenium scolopendrium. described by Linnaeus in 1753, is common in the British Isles and is rare to frequent in Europe (LOve 1954, Small 1938).

In 18494 Gattinger discovered the species in Roane County, Tennessee (Maxon 1900): in 1857. Hincks found it in Grey County, Ontario. Canada (Soper 1954).

In 1953, Hall and Hagenah discovered the species growing in Chippewa County, Michigan (Hagenah 1953).

Osterlund. Batchelder. and Short discovered it in Jackson County.

Alabama, in 1979 (Batchelder 1979. Short 1979).

Fernald described the taxon Asplenium (Phyllitis) scolopendrium var.

americanum in 1935.

He distinguished it from the European variety on the basis of several distinct morphological features.

These features include smaller fronds (3.5 to 23.5 inches [9to 60 cm]) versus 4.25 to 13.5 inches [11to 34 cm]). fewer and shorter indusia (coverings over the son), the presence of elongate tips on frond veinlets, and the distance of the veinlets from the edge of the frond (Fernald 1935).

Britton (1953) determined that, in addition to the morphological characters described by Fernald. the North American representatives of Asp lenium scolopendrium differed from European plants cytologically due to the fact that they have 144 rather than 72 chromosomes.

Lellinger (1985) also notes that Phyllitis (Asplenium) scolopendrium var. scolopendrium is much more easily cultivated than is Phyllitis (Asplenium) scolopendrium var.

scolopendrium var. americana.

LOve and LOve (1973) included the

I Figure 1 American harts tongue.

Reprinted by permission of the Biological Survey, New York State Museum, Albany, New York.

Originally published in Ogden (1981).

2

American harts-tongue within their concept of Phyllitis japonica Kom. and designated it ssp. americana (Fern.) LOve and LOve.

Kartesz and Gandhi (1991) include the genus Phyllitis within Asplenium, and their treatment is followed here.

Current Status and Distribution In North America, Asplenium scolopendrium var. americanum is found growing on or at least in close association with dolomitic limestone (limestone high in magnesium).

This extremely rare fern is currently known from only seven counties in the Canadian Province of Ontario, two counties in New York. two counties in Michigan. two counties in Alabama. and one county in Tennessee.

In the northern part of its range it usually occurs on or adjacent to dolomitic limestone outcrops.

The southern populations are found only within limestone pits that trap cold air, have high humidity, and are well shaded.

At all known locations, American harts-tongue appears to require high

humidity, shaded conditions, a moist substrate, and the presence of dolomitic limestone.

In the 183 years that have elapsed since first being discovered in North America, American harts-tongue has remained an extremely rare taxon found in small, widely disjunct groups of populations.

Concern for the continued existence of this species has long been voiced by those interested in the preservation of the flora of the United States.

This concern is demonstrated in early articles by Benedict (1925)

Saving the Harts-tongue; House (1934)

Saving the Scolopendrium Fern: and Faust (1960)

Survival of Harts-tongue Fern in Central New York.

Asp lenium scolopendrium var. americanum remains vulnerable to extinction throughout most of its range.

A description of the species status in each North American State or Province in which it occurs is provided below:

Alabama.

There are two known populations of American harts-tongue in Alabama.

Both populations were discovered by cavers associated with the Huntsville Grotto of the National Speleological Society (Batchelder 1979.

Evans 1982).

One population occurs in a Jackson County sinkhole on lands managed as a national wildlife refuge by the U.S.

Fish and Wildlife Service.

Short (1979) observed 20 plants present when he first visited the site.

Evans (1981) found that the population had dwindled to nine plants by July 1981.

Evans further stated that this population appears, for undetermined reasons, to be in a static or declining condition.

In 1990. members of the Huntsville Grotto surveyed the site and found only four plants (Huntsville Grotto 1990).

In 1993 this site supported only two plants (Robert Currie, U.S. Fish and Wildlife Service, personal observation).

The other population is in Morgan County, in the privately owned pit entrance to a limestone cave.

This population is located about 25 miles (40 kilometers) southwest of the Jackson County population (Short 1980).

Evans (1981) reported that this site contained a vigorous, healthy, reproducing population, which in 1981 supported 97 plants (26 fertile adults. 13 subadults, and 3

58 juveniles).

Haynes Currie (in litt.) reports that this population had declined to about 50 plants by 1989.

Members of the Huntsville Grotto resurveyed the site in 1990 and reported that the population had further declined to 39 plants. 85 percent of which had fertile fronds (Huntsville Grotto 1990).

Alabama does not directly protect endangered and threatened plants.

However. American harts-tongue is protected as a form of cave life by the Alabama Cave Conservation Act of 1988.

Tennessee.

Tennessee has two records of American harts-tongue.

The first of these was discovered in the entrance to a Roane County cave byGattinger in 1849.

Despite repeated searches for the plant at this site since the early 1900s.

it has not been seen again and is considered to be extirpated from the area (Maxon 1900. Shaver 1954, Evans 1981).

The only extant Tennessee population is in Marion County and was discovered by Cheatham in 1879 (Williamson 1879. Evans 1981).

Originally supporting about 200 plants, this population contained only about 17 plants in 1980 (Evans 1981).

G.

Ramseur (University of the South. personal communication, 1993) reported that only one or two depauperate plants remained in 1991 and that the species may soon be extirpated from Tennessee.

Early concern about the decline of this population led Graves to scatter American harts-tongue spores at the site in 1929.

The spores were obtained from a plant collected in Ontario. Canada (McGilliard 1936).

There appear to be no morphological characters that distinguish Tennessees representatives of this taxon from the Canadian representatives; therefore, without electrophoretic or other genetic analysis, it will be impossible to know the origin of the few plants that survive.

From 1982 to the present time, the site has been leased by The Nature Conservancy for the express purpose of protecting this species.

This species is listed in Tennessee under the Rare Plant Protection and Conservation Act.

Taking without the permission of the landowner or land manager is prohibited by the Act.

MichiQan.

The Michigan Natural Features Inventory (MNFI)

(1990) recognizes six extant occurrences of American harts-tongue (M. Penskar. MNFI, personal communication.

1993).

Five of these sites are in Mackinac County. and one is in Chippewa County.

The Chippewa County site was thought to have been destroyed by collecting in 1975.

However.

Don Drife (in litt.)

reports that he has observed the site since 1976.

When he first visited the site there were no plants present.

In 1979. he observed two immature plants.

In 1988, one of these plants was found to have died.

In 1992. one fertile-leaved plant remained at the site.

Two of the Michigan sites are owned by the Michigan Nature Association (Association).

Both of the Associations occurrences are healthy and support several hundred plants each.

Two locations are on land managed by the U.S.

Forest Service (Hiawatha National Forest)

(Henson 1978 and Vande Kopple 1992).

One population contains approximately 64 plants.

To protect this occurrence, the Forest Service rerouted a trail that was proposed for the area (Voss in litt.).

This occurrence may now be threatened by logging close to the plants (Penskar and Weise.

in 4

litt.)

In 1991 Janet Schultz.

a Forest Service ecologist, discovered an additional population.

This site was inventoried by Vande Kopple in 1992 and was found to support 532 plants.

The last occurrence is on privately owned, unprotected land near the two occurrences owned by the Association.

The history and biology of this species in Michigan is provided by Nepstad (1981),

Futyma (1980). Hagenah (1953, 1956), and Vande Kopple (1992).

American harts-tongue is listed as endangered under Michigans Endangered Species Act.

This Act prohibits taking on all public and private lands without a permit.

New York.

The plight of Asp lenium scolopendrium var. americanum in New York has been carefully documented since the early 1900s (Hunter 1922. Faust 1960. Cinquemani et a!. 1989).

The delineation of individual occurrences provided here is that used by the New York Natural Heritage Program (Young in litt.).

Their identification of occurrences is based primarily upon Faust (1960), Hunter (1922). and Cinquemani-Kuehn et a!.

(1989).

The fern is known from a limited area within Madison and Onondaga Counties.

Seventeen occurrences are currently recognized by the program; three of these are in Madison County. and fourteen are or were in Onondaga County.

Five of the fourteen Onondaga County occurrences are believed to be extirpated.

Three of these were destroyed by quarrying operations between 1924 and 1935 and two by undetermined means, one soon after 1959 and one in the late 1980s.

Six occurrences are small and vulnerable; in 1988, they contained 39, 41. 49.

140, 271. and 371 individuals, respectively (Cinquemani in litt.).

The remaining three occurrences are the largest in New York and indeed are the largest occurrences in the United States.

These occurrences are located in a State park, and in 1988 they contained a combined total of 2.341 individuals (Cinquemani in litt.).

Madison County supports three occurrences.

Two of these, containing 48 and 54 plants, respectively, are on unprotected, privately owned lands.

The third, which contained 346 plants in 1988, is within a State park (Cinquemani in litt.).

About half of the plants that were originally in the park were destroyed before 1980 by trail construction and subsequent erosion.

Plants from one Madison County population were raised from spores and were transplanted to a site in Montgomery County in the 1940s, where 16 plants are still extant (Young in litt.).

In New York the species is protected under the Protected Native Plants Law.

This law prohibits the removal of the fern without landowner permission.

Violators are subject to a $25 fine.

Canada.

Asp lenium scolopendrium var. americanum is listed as a rare species in the Atlas of the Rare Vascular Plants of Ontario (Argus and Pryer 1990).

Although locally abundant in the center of its range in Grey County, it was included in the Atlas

.because most 5

of its world population occurs in the Province.

On a continental basis, this is a very small area and all of the peripheral populations in the United States are at risk (Dickson and White 1983).

Adjacent southern Bruce County also supports healthy populations of the taxon.

Much smaller and more isolated populations occur in Peel, Halton. Dufferin. and Simcoe Counties (Soper 1954.

Britton in litt.).

There is a historic occurrence located near Niagara Falls in Welland County.

Soper (1954) states that these plants may have been transplanted to the site in the late 1800s.

No plants have been observed there since 1925 (Dickson and White 1983).

Fernald (1970) includes New Brunswick in his description of the range of American harts-tongue.

However. Hinds (in litt.) states that the material collected in New Brunswick is the European variety and that the species is not believed to be native to the Province.

Life History and Habitat Requirements Ostlie (1990) provides the following discussion of this species life history and habitat needs (note that throughout this section the synonym Phyllitis is used for Asp!enium):

Phyllitis scolopendrium var. americana reproduces only via spores.

Sporelings apparently require the presence of cool.

moist. calcareous environments for development (Crispin and Penskar 1990).

Bryophytes appear crucial to the survival of P. scolopendrium var. americana sporelings (Cinquemani-Kuehn and Leopold.

in review).

Bryophyte beds apparently enhance seedling regeneration, providing a favorable site for fertilization, spore germination, and gametophyte growth.

Reduced temperature extremes and moisture maintenance likely protect P. scolopendrium from desiccation during its early stages of growth.

Over 80% of all sporelings observed at sites in New York occurred on bryophyte beds (Cinquemani-Kuehn and Leopold. in review).

As P. scolopendrium sporelings mature, they apparently out-compete bryophytes for available resources and replace them (Cinquemani-Kuehn and Leopold. in review).

An indirect correlation between percent bryophyte cover and life stage of Phyllitis was noted in New York; the older a given harts-tongue became, the less likely it would be found growing on bryophyte mats.

Distribution of P. scolopendrium is also apparently affected by herbaceous cover.

Cinquemani-Kuehn and Leopold (in review) found that most adult plants were found beneath 0-25 percent herbaceous cover, while most sporelings were found beneath a higher percentage (26-50 percent) of herb cover.

Few individuals of any life stage were found where herbaceous cover exceeded 75 percent.

A lack of herbaceous cover over sporeling microsites typically resulted in lower 6

sporeling vigor.

Herbs probably aid sporeling growth by maintaining humidity and preventing desiccation of sporelings and, as a result, function similarly to bryophytes.

Since sporelings have no effective root system, they do not readily compete with other herbaceous plants for resources.

Mature P. scolopendrium, however, likely compete with other herbs for resources.

When mature harts-tongue fully occupy a site, very few other herbs are present (Cinquemani-Kuehn and Leopold.

in review).

The presence of shrubs is directly associated with sporeling vigor, but only indirectly with overall vigor (Cinquemani-Kuehn and Leopold.

in review).

Although shrubs likely create ideal germination and early lifestage growth sites.

they eventually provide too much shade for maturing P.

scolopendrium.

Positive relationships between sporeling vigor and substrate crevice depth were observed at New York sites (Cinquemani-Kuehn and Leopold.

in review).

Although crevice depth is apparently important in preventing desiccation during summertime droughts, it is not a factor in preventing desiccation during periods of freezing temperatures and absent snow cover.

Winter snow cover is apparently necessary for the vigor and long-term survival of a population.

During periods of insufficient snow cover, P. scolopendrium may not be able to obtain adequate soil moisture and may be adversely affected by frost heaving (causing dislodged root system) and direct cold damage to individual plants (Cinquemani-Kuehn and Leopold 1992).

In fact, distribution of this taxon in North America is apparently strongly influenced by depth of snow cover.

Where populations are found in the northern United States and Canada. annual snowfalls range from 200-300 cm per year.

Annual snowfalls greater than this probably persist longer into the summer and prevent individuals from obtaining enough springtime sunlight.

Annual snowfall less than this amount likely leads to freeze damage (Cinquemani-Kuehn and Leopold 1992).

Slope position has been correlated with percent cover of P. scolopendrium at all life stages (Cinquemani-Kuehn and Leopold.

in review).

Individuals occur predominantly at upper and mid-slope positions, but are absent from the lower slope areas.

Although significantly more nutrients are available at the lower slopes. P. scolopendrium growth is apparently not limited at upper slope areas.

The absence of P. scolopendrium on lower slopes may be attributable to the lingering of winter snow during the spring at such sites (Cinquemani-Kuehn and Leopold 1992. Faust 1960).

7

The species appears to be able to colonize early successional habitats, as evidenced by a population found within a young Populus grove in Ontario (Futyma 1980).

In fact, most northern populations occur in forests of secondary growth.

where canopy openings are somewhat more abundant.

Cinquemani-Kuehn and Leopold (in review) found a direct correlation between sporeling vigor and openings in the tree canopy.

Gaps allow light and precipitation to reach sporelings during normal periods of precipitation.

During drought periods or deforestation events (leaf miners, gypsy moths), however, sporelings growing directly beneath the openings are likely injured by higher light intensities (Cinquemani-Kuehn and Leopold. in review: Crispin and Penskar 1980).

Sporelings growing under the edges of canopy openings receive adequate light and precipitation amounts and are also protected from desiccation during drought periods (Cinquemani-Kuehn and Leopold, in review).

Phyllitis scolopendrium rarely occur beneath conifers in New York (Cinquemani-Kuehn and Leopold.

in review) and Michigan (Futyma 1980).

When present, the most prominent conifer in New York was Tsuga canadensis (Cinquemani-Kuehn and Leopold.

in review).

The harts-tongue is probably restricted from the areas of conifers by a number of factors:

(1) concentrations of magnesium, calcium, potassium. percent nitrogen and organic matter were lower under conifers, (2) reduction of light intensity reaching P. scolopendrium under Tsuga in comparison to hardwood sites during early spring, (3) lack of protective winter snow beneath conifers, and (4) lack of bryophytes for sporeling germination sites beneath conifers (Cinquemani-Kuehn and Leopold, in review).

Fronds of the harts-tongue remain green and functional throughout the winter and following growing season (Crispin and Penskar 1990).

New fronds are produced at the start of each growing season and likewise remain functional for two growing seasons.

In Michigan, new fronds typically emerge in mid-June.

Spores are produced on year-old fronds from May through August (MNFI 1990).

Current Threats American harts-tongue is threatened throughout most of its range by trampling, habitat alteration, destruction by timber removal, quarrying, and residential development (Evans 1981.

Nepstad 1981).

The southern populations are especially vulnerable to extirpation by inadvertent trampling because of their small size and the steep, precarious nature of their habitat.

Short (1979) reports that between October 21.

1978. and November 24, 1978, one of the 20 plants that occurred at the Jackson County, Alabama, site was destroyed by someone who had apparently slid off the main trail and onto the plant.

Evans (1981) reports that in July 1981 only nine plants 8

remained at this location.

Quarrying operations destroyed three of New Yorks populations, and quarrying remains a threat to at least one of the remaining New York sites and two of the southern sites (Clemants in litt.. Evans 1981).

Timber removal at most of the sites would be expected to raise light levels and lower humidity levels to the detriment of the species.

Alterations associated with residential or other development would, in most cases, either directly destroy the plants present or result in environmental changes that would make the sites unsuitable.

Britton (in litt.)

stated that lumbering, quarrying, or other types of development are the most significant threats to the Ontario populations of the species.

Commercial trade in Asp lenium scolopendrium var. americanum is limited.

The material currently in trade is believed to be of cultivated origin and not obtained from the wild.

The original source of this material was one of the New York populations destroyed in the early 1900s by quarry operations (S. Clemants, New York Natural Heritage Program, personal communication, 1988).

Most of the populations in New York. Michigan, Alabama, and Tennessee are much too small to support any collecting for scientific purposes, for fern enthusiasts, or for other reasons.

Inappropriate collecting of entire plants remains a threat to these populations (Nepstad 1981).

The larger Ontario populations have withstood, apparently without ill effects, low levels of collecting for some time (Pryer in litt.).

Because of climatic changes, the southern populations of the species are restricted to extremely rare sites with physical environments similar to conditions under which the northern plants grow.

During the Wisconsin Glacial Period, the species may have been more widespread in southern limestone areas, but as the climate has

warmed, it has become restricted to a few sites in or near caves (Evans 1982).

Crispin (personal communication, 1986) reports that in 1985 an infestation of leaf miners destroyed the leaves on the trees above one of the Michigan sites.

The loss of shade that resulted from this alteration of the canopy desiccated many of the ferns growing on the forest floor.

Insect infestations that temporarily remove the leaves of the canopy or result in long-term damage to the trees found there remain a potential threat to the species.

9

PART II RECOVERY A.

Recovery Ob.iectives American harts-tongue (Asplenium scolopendrium var. americanum) will be considered for delisting when there are at least 15 self-sustaining populations of the species in the United States (2 in Alabama, 2 in Tennessee. 4 in Michigan. and 7 in New York). which are protected to such a degree that the species no longer qualifies for protection under the Endangered Species Act.

A self-sustaining population is a reproducing population that is large enough to maintain sufficient genetic variation to enable it to survive and respond to natural habitat changes.

It must also occur within a sufficiently large area to ensure that, to the extent possible, natural processes within its habitat can continue without adversely affecting the population and that active management required to maintain suitable habitat is minimal.

The number of individuals necessary and the quantity and quality of habitat needed to meet these criteria will be determined as one of the recovery tasks.

These recovery objectives are considered an interim goal.

Because of the lack of specific data on genetic diversity.

biology, and management requirements of the species, the recovery objectives may be modified at a later date as additional information is acquired.

This information may permit refinement of the estimate of populations required to ensure the continued survival of American harts-tongue.

This objective will be reassessed at least annually in light of any new information that becomes available.

The first step toward recovery will be protection and management of all extant populations to ensure their continued survival.

Little is known about the specific biological and habitat requirements of this species.

Therefore, it will be necessary to conduct detailed genetic and demographic studies and ecological research for the purpose of gaining the understanding needed to develop appropriate protection and management strategies.

The ultimate effects of various kinds of habitat disruption must be determined and, if necessary, prevented.

Active management may be required to ensure continued survival and vigor.

Therefore, American hart~s-tongue shall be considered for removal from the Federal list when the following criteria are met:

1.

It has been documented that at least 15 populations in the United States (2 in Alabama.

2 in Tennessee. 4 in Michigan, and 7 in New York) are self-sustaining and occur on sufficiently large tracts to ensure their perpetuation with a minimal amount of active management.

10

2.

All of the populations and their habitat are protected from present and foreseeable human-related and natural threats that may interfere with the survival of any of the populations.

B.

Narrative Outline 1.

Protect existinQ DoDulations and essential habitat.

Only 21 populations of American harts-tongue are currently known to exist in the United States.

Until more is known about the species biology, genetic diversity, and specific habitat requirements, and the measures necessary to protect the integrity of occupied sites, all existing populations must be protected.

The long-term survival of 15 populations in four States is believed to be essential to the perpetuation of the species as a whole.

1.1 Develop interim research and detailed site-specific manaQement Dlans in coniunction with landowners 1.2 Search for additional DoDulations and characterize all known Dopulations.

Several intensive searches have been conducted within the known range of American harts-tongue.

However, a thorough, systematic effort to locate additional populations and to carefully describe the nature of the habitat occupied by the species is needed.

Searches should be preceded by an examination of soil, geologic and topographic maps, and aerial photographs to determine potential habitat and to develop a priority list of sites to search.

Quantitative and qualitative characterization of all sites must be made.

Methods used should follow Cinquemani et a!.

(1989) and Cinquemani-Kuehn and Leopold (in review.

1992).

1.3 Determine protection Driorities.

Because of the small number of existing populations and the pervasive threats to the habitat, it is essential to protect as many populations as possible.

However, efforts should be concentrated first on the sites in public ownership, or where current private landowners are cooperative, and where the largest and most vigorous populations occur.

1.4 Imolement habitat protection alternatives.

The greatest possible protection must be obtained for most existing populations since all may be critical to the recovery of the species.

Fee simple acquisition or conservation easements provide the greatest degree of protection.

However, it is unknown as yet how much buffer land around each population is necessary to protect the integrity of occupied sites.

Protection through management agreements or short-term leases may provide 11

adequate short-term protection but can only be considered as an intermediate step in the process of ultimately providing for permanent protection.

Short-term protection strategies may be necessary if private landowners are not agreeable to or monies are not available for acquisition of conservation easements or fee simple title.

Conservation agreements with adjacent landowners or owners of rights-of-way (power companies, highway departments, etc.) must be developed to prevent inadvertent adverse alterations of the habitat.

This task should be initiated by formally contacting all landowners and notifying them of the presence of the species, its vulnerability, and the need to protect it from adverse activities.

2.

Determine and imDlement manaciement necessary for lonci-term reproduction. establishment, maintenance, and vicior Protection of the species habitat is the obvious first step in ensuring its long-term survival, but this alone may not be sufficient.

Habitat management may be necessary to allow the species to perpetuate itself over the long term.

However.

since relatively little is known about this species, information on its genetic diversity, population biology, and ecology is necessary before effective management guidelines can be formulated and implemented.

2.1 Determine Dopulation size and stacie-class distribution for all DoDulations.

Population size and stage-class (size) distribution data are essential to predicting what factors may be necessary for populations to become self-sustaining (Menges 1987).

Such data are needed for existing populations and for any newly discovered populations.

This task should be combined with the work described under Task 1.2.

This will ensure that funds are utilized in the most efficient manner.

2.2 Study abiotic and biotic features of the soecies

habitat.

An understanding of the nature of the habitat occupied by the species is essential to the long-term survival and recovery of American harts-tongue.

Required monitoring studies will include populations within a wide range of habitats, both altered and undisturbed.

Permanent plots will be selected and established to determine the relationship between abiotic factors (such as soil depth and type.

soil moisture content, and light intensity) and biotic factors (such as reproduction, germination, and degree of competition and predation).

This information is necessary to determine the appropriate timing and type of management needed to ensure the continued vigor of existing populations and to accurately select good potential sites for reintroduction if necessary.

12

Special emphasis will be placed on determining the nature of the biotic and abiotic factors that permit the continued presence of the species at the southern sites in Alabama and Tennessee.

Potential competition from other species, including exotics. will be examined.

2.3 Conduct lonci-term demographic studies and determine cienetic variability within and between poDulations Long-term demographic studies must be conducted in permanent plots located within each study site established for habitat analysis.

Plots should be visited annually, for at least 4 consecutive years.

The locations of individual plants of all stage-classes should be mapped; data collected should include overall plant size and the number and size of leaves.

Larger plots, surrounding each of the smaller, more intensively measured and mapped plots, should be monitored for sporeling establi shment.

Sporelings should be mapped and measured.

Any changes in the habitat within each plot (soil disturbance, increases or decreases in light intensity, moisture. etc.) should be noted at each visit.

Through isozyme analysis, the degree of genetic variability within and between populations should be determined.

This information will be essential to the determination of the location, distribution, and number of populations that need to be protected to ensure the long-term survival of the species.

All monitoring must be conducted in a manner that eliminates or significantly reduces adverse impacts on the populations being studied.

2.4 Determine the effects of Dast and oncioinci habitat disturbance.

Establishment and long-term monitoring of permanent plots may be the most effective means of assessing the effects of disturbance.

Appropriate methodology for this must be determined but will likely include measurement of many of the parameters specified in Tasks 2.2 and 2.3.

2.5 Define criteria for self-sustaininci populations and determine the size of the area needed to protect each population.

Currently, there is insufficient data to determine what this species requires in order for populations to be self-sustaining and how large an area is needed to allow natural processes to continue without adversely affecting the size and health of the species population as a whole.

Research as described under Tasks 2.2 through 2.4 should provide the information needed to protect and, if necessary, manage occupied habitat so that the continued survival of healthy populations is assured.

13

2.6 ImDlement appropriate manaciement techniques as they are develooed from previous tasks 2.7 Develop techniques and reestablish populations in suitable habitat within the species historic rancie Techniques for propagation and transplantation of this species must be summarized and disseminated to appropriate organizations and individuals.

Reintroduction efforts will have to be conducted in cooperation with knowledgeable personnel at private nurseries, botanical gardens, and the Center For Plant Conservation.

When established, transplant sites in suitable habitat must be closely monitored to determine success and to adjust methods of reestablishment.

3.

Maintain cultivated sources for the species and provide for lonci-term maintenance of selected populations in cultivation 4.

Enforce laws orotectinci the species and/or its habitat Ferns are collected from the wild and sold as ornamentals.

American harts-tongue is not currently known to be a significant part of this trade, but this could become a threat in the future.

The Endangered Species Act prohibits taking of the species from Federal lands without a permit and regulates trade.

Section 7 of the Act provides additional protection of the habitat from impacts related to federally funded or authorized projects.

In addition, for listed endangered plants, the 1988 amendments to the Act prohibit:

(1) their malicious damage or destruction on Federal lands and (2) their removal, cutting, digging, damaging, or destruction in knowing violation of any State law or regulation, including State criminal trespass law.

Asplenium scolopendrium var. americanum is listed as endangered under Michigans Endangered Species Act and Tennessees Rare Plant Protection and Conservation Act.

In Michigan, taking without a permit is prohibited on all public and private lands: in Tennessee, taking is only restricted when the permission of the landowner or manager has not been obtained.

In New York, the species is protected under the Protected Native Plants Law, which states that removal of the fern without the landowners permission is a violation of the law and subjects the violator to a $25 fine.

In Alabama.

harts-tongue is protected as a form of cave life by the Alabama Cave Conservation Act of 1988.

5.

Develoo materials to inform the public about the status of the species and the recovery olan ob.iectives.

Public support for the conservation of American harts-tongue could play an important part in encouraging landowner assistance and conservation efforts.

This is especially true for the populations that occur in areas being adversely affected by 14

development associated with expanding urban areas.

Information materials must not identify the plants locations so as not to increase the threat of taking.

Cooperative education efforts with groups such as the National Speleological Society and its member grottos. native plant societies, and the Garden Club of America should be initiated.

5.1 Prepare and distribute news releases and informational brochures.

News releases concerning the status and significance of the species and recovery efforts should be prepared and distributed to major newspapers in the range of the species, as well as to smaller newspapers in the vicinity of the species habitat.

5.2 Prepare articles for popular and scientific publications.

The need to protect the species in its native habitat and cooperation among local, State. and Federal organizations and individuals should be stressed.

Scientific publications should emphasize additional research that is needed and solicit research assistance from colleges and universities that have conducted studies on this or closely related species.

6.

Annually assess the success of recovery efforts for the species.

Review of new information, evaluation of ongoing actions, and redirection, if necessary, is essential for assuring that full recovery is achieved as quickly and efficiently as possible.

15

C.

Literature Cited

Argus, G. W., and K.

M. Pryer.

1990.

Rare Vascular Plants in Canada

- Our Natural Heritage.

National Museum of Natural Sciences. Ottawa.

191 pp.

+ maps.

Batchelder.

E.

1979.

The Harts-tongue Discovery.

Grotto News.

20(6):49-50.

Huntsville Benedict.

R.

C.

1925.

Saving the Harts-tongue.

Amer.

Fern Jour.

15(4) :124-125.

Britton, D. M.

1953.

Bot. 40:575-583.

Chromosome studies in ferns.

Amer.

Jour.

Cinquemani, D. M.,

M.

E.

Faust, and D. J.

Leopold.

Periodic censuses of Phyl!itis scolopendrium var.

americana Fernald since 1916 in central Amer. Fern Jour.

78(2):37-43.

Cinquemani-Kuehn. D. M.. and 0.

characteristics associated Newm.

var. americana Fern.

Torrey Bot. Club.

1989.

(L.) Newman New York State.

J.

Leopold.

In review.

Site with Phyllitis scolopendrium (L.)

in central New York.

Bull.

1992.

Long-term demography of Pyllitis scolopendrium (L.) Newm.

var. americana Fern.

in central New York state.

Bull. Torrey Bot. Club 119(1):65-76.

Crispin.

S.. and americana.

Inventory.

M. Penskar.

1990.

Phyllitis scolopendrium var.

Unpublished abstract. Michigan Natural Features Endangered Species Manual.

3 pp.

Dickson, H.

L..

and 0.

J. White.

1983.

Asp leniaceae

- Phy!litis scolopendrium (L.) Newman var. americana Fernald in G. W. Argus. and 0.

J. White (eds.).

1983.

Atlas of the Rare Plants of Ontario.

Nat. Mus. Nat. Sci.. Ottawa.

Evans. A.

M.

1981.

Status Report on (L.) Newm.

var. americana Fern.

USFWS. Southeast Region.

1982.

The harts-tongue cave entrances.

In National proceedings 1978 and 1980.

Oregon.

234 pp.

Phyllitis scolopendrium Unpublished report to fern--an endangered plant in Cave Management Symposia Pygmy Dwarf Press. Oregon City, Faust. M.

E.

1960.

Survival of Harts-tongue Fern in Central New York.

Amer.

Fern Jour. 50:55-62.

16

Fernald. M.

L.

1935.

Region of Ontario 238-262, 272-301.

Critical Plants of the Upper Great Lakes and Michigan.

Rhodora. 37(438):197-222.

324-341.

(Desc. on pages 220-221.)

1970.

Grays Manual of Botany.

D. Van Nostrand Co.. New York.

Futyma. R.

P.

1980.

scolopendrium in Eighth ed.

The Distribution and Ecology of Phyllitis Michigan.

Amer.

Fern Jour. 70(3):81-87.

Hagenah, D.

J.

1953.

Rare Harts-tongue Fern Found in Michigan.

Cranbrook Inst. Sci.

News Letter.

23(1):2-5.

1956.

More Harts-tongue in Michigan.

Jour. 46:70-74.

Amer.

Fern Henson. Don.

1978.

Survey and mapping of Harts-tongue fern in 1.000-acre area of Hiawatha National Forest.

Unpublished report.

USDA, Forest Service.

14 pp.

House. H.

D.

1934.

Saving the Scolopendrium Fern.

Jour. 24(3):65-71.

Amer. Fern Hunter.

M.

1922.

The Present Status of Scolopendrium in New York State.

Amer.

Jour.

Bot. 9(1):28-36.

Huntsville Grotto.

1990.

Unpub1 i shed report.

American harts-tongue fern notes.

3 pages.

Kartesz. John T.. and K.

N. Gandhi.

1991.

Nomenclatural Notes for the North American Flora V.

Phytologia 70:194-208.

Lellinger.

D.

B.

Fern-Allies Institution 1985.

of the Press.

A Field Manual of the Ferns and United States and Canada.

Smithsonian Washington.

D.C.

389 pp.

LOve, Askell.

1954.

Cytotaxonomical Remarks on Some American Species of Circumpolar Taxa.

Svensk. Bot.

Tidskr.

48(1) :211-232.

LOve. A., and D.

Phyllitis.

19: 201-206.

LOve.

1973.

Cytotaxonomy of the Boreal Taxa of Acta Botanica Academiae Scientarum Hungaricae.

Maxon.

W.

R.

1900.

On the Occurrence of the Harts-tongue in America.

Fernwort Papers.

Pp. 30-40.

McGilliard.

E.

1936.

The Harts-tongue in Tennessee 1878-1935.

Amer.

Fern Jour.

26(4):113-122.

17

Menges, E.

1987.

populations:

Areas Journal Predicting the future of rare plant demographic monitoring and modeling.

Natural 6(3) :13-25.

Michigan Natural Features Inventory.

1990.

Phyllitis sco!opendrium var. americana.

Nepstad, D.

L.

Fernald.

Region.

Database records for 2 pp.

1981.

Phyllitis scolopendrium var. americana Unpublished status report to USFWS, North central Ogden.

E.

C.

1981.

Field Guide to Northeastern Ferns.

Bull. 444. New York State Museum. Albany, New York.

Ostlie, Wayne.

1990.

sco lopendrium var.

Unpublished report.

Element Stewardship Abstract americana

- American Harts The Nature Conservancy.

for Phyllitis tongue.

18 pp.

Shaver. Jesse M.

1954.

Ferns of the Eastern Central States with Special Reference to Tennessee.

Dover Publications.

1970 reprint of the 1954 edition.

Short. J. W.

Alabama.

1979.

Phyl!itis scolopendrium Newly Discovered in Amer. Fern Jour. 69(2):47-48.

1980.

A Second Alabama Locality for the Harts-tongue.

Amer. Fern Jour. 70(4):137.

Small, J.

K.

1938.

Publishing Co..

Ferns of the Southeastern States.

Hafner New York (1964 Facsimile edition).

Soper.

J.

H.

1954.

The Harts-tongue Fern in Ontario.

Amer.

Fern Jour. 44(4):129-147.

U.S. Fish and Wildlife Service.

1989.

Endangered and threatened wildlife and plants: Threatened Status for Phyllitis scolopendrium var. americana (American harts tongue fern).

Federal Register 54(134) :29726-29730.

Vande Kopple, Robert J.

Fern.

Unpublished 8 pp.

1992.

report A New Colony of Harts-tongue to Hiawatha National Forest.

Williamson, John.

1879.

Scolopendrium vulgare discovered in Tennessee.

Bull. Torr.

Bot.

Club.

6(57):347-348.

122 pp.

18

PART III IMPLEMENTATION SCHEDULE Priorities in column one of the following implementation schedule are assigned as follows:

1.

Priority 1

- An action that must be taken to prevent extinction or to prevent the species from declining irreversibly in the foreseeable future.

2.

Priority 2

- An action that must be taken to prevent a significant decline in species population/habitat quality or some other significant negative impact short of extinction.

3.

Priority 3

- All other actions necessary to meet the recovery objecti ye.

Key to Acronyms Used in This Implementation Schedule FWS

- U.S. Fish and Wildlife Service TE

- Endangered Species Division of the U.S. Fish and Wildlife Service LE

- Law Enforcement Division of the U.S. Fish and Wildlife Service PA Public Affairs Office of the U.S. Fish and Wildlife Service RW

- Refuges and Wildlife Division of the U.S. Fish and Wildlife Service CPC

- Center for Plant Conservation FS

- U.S. Forest Service MNA

- Michigan Nature Association SCA

- State Conservation Agencies, including the following:

Alabama Natural Heritage Program, New York Department of Environmental Conservation, New York Office of Parks, Recreation and Historic Preservation, Michigan Natural Features Inventory, and Tennessee Department of Environment and Conservation TNC

- The Nature Conservancy 19

AMERICAN HARVS-TONGUE IMPLEMENTATION SCHEDULE

[Priority 1

Task Number 1.1 I

Tast Re~nsib1e A~CP~CY Cast Estiwates (~OOQ Task Description IAon Other FY1FY2FY Connents Develop research/management 2 years R3, 4, FS, MNA, 10.0 10.0 plans.

and 5/TE SCA, TNC and RU 1

1.3 Determine priorities.

1 year R3, 4, and 5/TE SCA 5.0 1

1.4 Implement protection.

3 years R3, 4, and 5/TE and RU FS,

MNA, SCA, TNC 20.0 20.0 20.0 Doesnt incLude acquisition costs.

1 2.2 Study habitat.

4 years R3, 4, and 5/TE FS, SCA 15.0 15.0 15.0 Expansion of work conducted in New York.

1 2.3 Demographic and genetic studies.

4 years R3, 4, and S/TE FS, ScA 30.0 15.0 15.0 Combine with Task 2.2.

1 2.5 Define self-sustaining and buffer areas.

1 year R3, 4, and 5/TE SCA 10.0 1

2.6 Implement management.

Ongoing R3, 4, and S/TE and RU FS,

MNA, SCA, TNC 7??

???

7??

1 3

Protect genetic material.

1 year R3, 4, and S/TE CPC, SCA 13.2 1

4 Enforce laws.

Ongoing R3, 4, and 5/

TE, LE, and RU FS, SCA No additional costs.

2 1.2 Search for new populations.

3 years R3, 4, and_5/TE R3, 4, and 5/TE SCA 15.0 15.0 15.0 acterize popuLations.

j:::

jchar Determine effects of disturbance.

2 years FS, SCA 10.0 10.0 Ongoing R3, 4, and 5/TE FS,

MNA, SCA, INC 50 5.0 5.0

)

)

)

c-s.,a

AMERICAN HARTS-TONGUE IMPLEMENTATION SCHEDULE (continued)

P PriorIty Task Number Task Description Task Duration Responsible Agency FWS Other Cost Estimates ($000 FYI Ff2 FY~

tonments 2

2.7 Reestablish populations, if necessary.

Unknown R3, 4, and SITE

CPC, SCA, TNC

??

7??

???

No additional costs.

2 6

Assess recovery success.

Ongoing R3, 4, and 5/TE SCA No additional costs.

3 5.1 News releases/brochures.

3 years R3, 4, and 5/TE, PA FS, SCA 5.0 5.0 5.0 3

5.1 Prepare articles.

Ongoing R3, 4, and 5/TE, PA SCA No additional costs.

9--

PART IV LIST OF REVIEWERS The Alabama Conservancy 2717 7th Avenue, Suite 201 Birmingham, Alabama 35233 Alabama Forestry Commission 513 Madison Avenue Montgomery, Alabama 36130 Alabama Natural Heritage Program State Lands Division 64 North Union Street, Room 752 Montgomery, Alabama 35205 Alabama Wildlife Federation 46 Commerce Street P.O. Box 2102 Montgomery, Alabama 36102 Mr. Milo Anderson Environmental Protection Agency Planning and Assessment Branch (5ME-19J) 77 West Jackson Boulevard

Chicago, Illinois 60604 Dr. John Beaman Department of Botany Michigan State University East Lansing, Michigan 48824 Mr. Michael Bean Chairman, Wildlife Program Environmental Defense Fund 1875 Connecticut Avenue, NW.

Washington, DC 20009 Mr. David S.

Beck Director of Governmental Affairs Kentucky Farm Bureau Federation P.O.

Box 20700 Louisville, Kentucky 40250-0700 Mr. Michael Birmingham, Director Division of Land and Forest Resources New York State Department of Envi ronmental Conservati on 50 Wolf Road, Room 406

Albany, New York 12233 22

Dr. Joseph Bitel New York Botanical Garden Bronx, New York 10458 Dr. Donald M.

Britton Department of Molecular Biology and Genetics University of Guelph Guelph, Ontario Canada N1G2W1 Mr. Dave Browlee Hiawatha National Forest U.S. Forest Service Escanaba, Michigan 49829 Mr. Larry Brown Significant Habitats Unit New York State Department of Envi ronmental Conservation Wildlife Resources Center

Delmar, New York 12054 Manager Chittenango Falls State Park Central Region Office of Parks, Recreation, and Historic Preservation Clark Reservation Jamesville. New York 13078 Dr. Anne B. Clark University Center at Binghamton State University of New York Binghamton, New York 13901 Manager Clark Reservation Central Region Office of Parks. Recreation, and Historic Preservation Jamesville, New York 13078 Dr. Leo Collins Forestry, Fisheries, and Wildlife Division Tennessee Valley Authority Norris, Tennessee 37828 23

Dr.

Bob Cook Arnold Arboretum 125 Arborway Jamaica Plain, Massachusetts 02130 Ms. Susan Crispin Michigan Natural Features Inventory Department of Natural Resources Box 30028, Stevens T. Mason Building Lansing, Michigan 48909 Ms. Bertha Daubenbiek Michigan Nature Association P.O. Box 102 Avoca, Michigan 48006 Mr. Donald Drife 1813 Beech Lane Troy, Michigan 48083 Dr. John Dunckelman Florida Sugar Cane League P.O. Box 1208 Clewiston, Florida 33440 Environmental Protection Agency Hazard Evaluation Division

- EEB (T5769C) 401 M Street, SW.

Washington, DC 20460 Dr. Murray A. Evans Botany Department University of Tennessee Knoxville, Tennessee 37916 Dr. Mildred Faust 1216 Westcott Street

Syracuse, New York 13210 Fish and Wildlife Reference Service 5430 Grosvenor Lane. Suite 110 Bethesda, Maryland 20814 Dr. John Freeman Botany and Microbiology Department Auburn University 129 Funchess Hall Auburn, Alabama 36849 24

Dr. Richard Futyma Biological Survey New York State Museum Albany, New York 12230 The Garden Club of America 598 Madison Avenue New York, New York 10022 Mr. Brad Garland P.O. Box 9101 Marshall Space Flight Center Huntsville, Alabama 35812 Dr. Erich Haber Botany Department Canadian Museum of Nature P.O.

Box 3443, Station D Ottawa, Canada K1P6P4 Mr.

Ben Hafer 2117 Andy Holt Avenue. #1527 Knoxville, Tennessee 37916 Ms.

Ethelba Hagenah 164 West Chester Way Birmingham, Michigan 48009 Mr. David Hales Department of Natural Resources Steven T. Mason Building P.O. Box 30028 Lansing, Michigan 48909 Mr. Don Henson Tamarack Studios P.O. Box 453 Manistique, Michigan 49854 Dr.

Harold Hinds Connel Memorial Herbarium University of New Brunswick Fredericton, New Brunswick Canada E3B6E1 Huntsville Grotto National Speleological Society P.O. Box 1702, West Station Huntsville, Alabama 35807 25

Dr. Roger Jenkins Sierra Club 1817 Chestnut Grove Road Knoxville, Tennessee 37932 Mr. Julius T. Johnson Director of Public Affairs Tennessee Farm Bureau Federation P.O. Box 313 Columbia, Tennessee 38401 Dr. Peter B.

Kaufman. President Michigan Botanical Club 8040 West Huron River Drive Dexter, Michigan 48130 Dr. Bob Kral Biology Department Vanderbilt University P.O. Box 1705, Station B Nashville, Tennessee 37235 Ms. Diane Kuehn 1001 South First Street, Apt. E-135 Fulton, New York 13069 Dr. Susan H. Lathrop, Executive Director American Association of Botanical Gardens and Arboreta, Inc.

786 Church Road Wayne, Pennsylvania 19087 Mr. Orin Lehman, Commissioner New York State Office of Parks, Recreation, and Historic Preservation Agency Building 1,

Empire State Plaza

Albany, New York 12238 Dr. David B. Lellinger Department of Botany National Museum of Natural History Smithsonian Institution Washington, DC 20560 Dr. Donald Leopold State University of New York College of Environmental Science and Forestry 5 Moon Library
Syracuse, New York 13210 26

Ms. Amy Lester The Nature Conservancy 1736 Western Avenue Albany, New York 12203 Mr. Robert McCartney Wood1 anders 1128 Colleton Avenue Aiken, South Carolina Mr. Peter D. McKone Freese and Nichols, 811 Lamar Street Fort Worth, Texas 29801 Inc.

76102 Dr. John Mickel New York Botanical Garden

Bronx, New York 10458 Dr. Richard S. Mitchell New York State Botanist Biological Survey of the New York State Museum Room 3132, Cultura Albany. New York 1 Education Center 12230 Hi story Department of Botany National Museum of Natural Smithsonian Institution Washington, DC 20560 Botany Division National Museum Ottawa, Ontario Canada K1A0M8 of Natural Sciences National Speleological Society Cave Avenue Huntsville, Alabama 35818 Natural Resources Defense 40 West 20th Street New York, New York 10011
Council, Inc.

The Nature Conservancy Southeast Regional Office P.O.

Box 2267 Chapel Hill, North Carolina 27515-2267 27

Di rector The Nature Conservancy P.O. Box 3017 Nashville, Tennessee 37219 The Nature Conservancy 1815 N. Lynn Street Arlington, Virginia 22209 New England Wildflower Society, Inc.

Garden in the Woods Hemenway Road Framington, Massachusetts 01701 Curator North Carolina Botanical Garden University of North Carolina Chapel Hill Totten Center 457-A Chapel Hill, North Carolina 27514 Mr. Peter Nye Endangered Species Unit New York State Department of Envi ronmental Conservation Wildlife Resources Center

Delmar, New York 12054 Ms. Peggy Olwell Center for Plant Conservation Missouri Botanical Garden P.O. Box 299 St. Louis, Missouri 63166-0299 Mr Wayne Ostlie The Nature Conservancy Mid-West Regional Office 1313 5th Street, SE.

Minneapolis, Minnesota 55414 Ms. Debra Owen Wool pert Consul tants 8731 Red Oak Boulevard Charlotte, North Carolina 28217-3958 Mr. Rich Owings North Carolina Arboretum P.O. Box 6617 Asheville, North Carolina 28816 28

Mr. Alan Parolini FB&D Technologies, Inc.

10497 Town & Country Way Houston, Texas 77024 Mr. Brian Parsons The Holden Arboretum 9500 Sperry Road Mentor, Ohio 44060 Dr. Mike Michigan P.O. Box

Lansing, Penskar Natural Features 30028 Michigan 48909 Inventory Mr. William H. Redmond Regional Natural Heritage Project Tennessee Valley Authority Norris, Tennessee 37828 Mr. Reginald Reeves, Tennessee Department and Conservation 401 Church Street 8th Floor, L&C Tower Nashvi 11 e, Tennessee Di rector of Environment 37243-0447 Dr. James L. Reveal, Chairman Conservati on Committee American Society of Plant University of Maryland Department of Botany College Park, Maryland 20742 Taxonomists Dr. Anton Reznicek University of Michigan Herbarium North University Building Ann Arbor, Michigan 48109-1057 Mr.

Ed Schell 2514 Browns Mill Road Johnson City, Tennessee 37601 Ms.

Ruth M. Scherer c/o Michigan Masonic Home 1200 Wright Avenue

Alma, Michigan 48801 29

Dr.

Fred C. Schmidt Head, Documents Department

- KS The Libraries Colorado State University Fort Collins, Colorado 80523 Mr. John Sherman Tennessee Environmental Council 1700 Hayes Street, Suite 101 Nashville, Tennessee 37203 Mr. Alan Smith P.O.

Box 887 Mars Hill. North Carolina 28754 Ms. Louise Smith 3221 Pine Ridge Road Birmingham, Alabama 35213 Mr. David C. Star Envi ronmental Scientist Pesticides & Toxic Substances Branch U.S. Environmental Protection Agency 77 West Jackson Boulevard

Chicago, Illinois 60604-3590 Mr. Gary Sullivan National Park Service Midwest Regional Office 1709 Jackson Street Omaha, Nebraska 68102 Tennessee Native Plant Society Department of Botany University of Tennessee Knoxville, Tennessee 37916 Dr.

George Win. Thomson 5066 Elmhurst Avenue Royal Oak, Michigan 48073-1102 Mr. Mike Turner U.S. Army Corps of Engineers Louisville District P.O.

Box 59 Louisville, Kentucky 40202 U.S. Forest Service Wildlife, Fisheries, and Range 1720 Peachtree Road, NW.

Atlanta, Georgia 30367 30

Regional Forester, Region 9 U.S.

Forest Service 310 W. Wisconsin Avenue Milwaukee, Wisconsin 53203 Dr. Bob Vande Kopple Resident Biologist University of Michigan Biological Stati on Pellston, Michigan 49769 Dr. Edward G. Voss University of Michigan Herbarium North University Building Ann Arbor, Michigan 48109-1057 Dr. Warren H. Wagner, Jr.

Botani cal Department Natural Science Building University of Michigan Ann Arbor, Michigan 48104 Dr.

Kerry S. Walter World Conservation Monitoring Centre 219c Huntingdon Road Cambridge CB3 ODL United Kingdom Ms. Susan Weber 1623 Monte Santo Boulevard Huntsville, Alabama 35801 Dr.

Eugene Wofford Curator of Herbarium Department of Botany University of Tennessee Knoxville, Tennessee 37916 Mr. Tom Woiwode, Director The Nature Conservancy 2840 East Grand River Avenue, Suite 5 East Lansing, Michigan 48823 Mr. Thomas A. Wojtalik Envi ronmental Engineer SP 4C-C Tennessee Valley Authority 1101 Market Street Chattanooga, Tennessee 37402 31

Traffic U.S.A.

World Wildlife Fund 1250 24th Street, NW.. Suite 500 Washington, DC 20037 Dr. Richard Zander Clinton Herbarium Buffalo Museum of Science Humboldt Parkway Buffalo. New York 14211 Dr. Peter Zika, Botanist New York Natural Heritage Program 700 Tray-Schenectady Road Latham. New York 12110-2400 32