ML18023A185
| ML18023A185 | |
| Person / Time | |
|---|---|
| Site: | Clinch River |
| Issue date: | 09/30/2015 |
| From: | Palmer S, Wisby J State of TN, Wildlife Resources Agency |
| To: | Office of New Reactors |
| Fetter A | |
| References | |
| Download: ML18023A185 (108) | |
Text
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Prepared by:
Patty Glick (National Wildlife Federation)
Sally Palmer and Joey Wisby (The Nature Conservancy - Tennessee)
For The Tennessee Wildlife Resources Agency Nashville, Tennessee September 2015
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Prepared by:
Patty Glick (National Wildlife Federation)
Sally Palmer and Joey Wisby (The Nature Conservancy - Tennessee)
For The Tennessee Wildlife Resources Agency, Nashville, Tennessee September 2015 Acknowledgements:
This report is the product of a collaborative effort between the Tennessee Wildlife Resources Agency (TWRA), The Nature Conservancy (TNC), and the National Wildlife Federation (NWF) to engage fish and wildlife species and habitat experts from across the state in a hands-on assessment of climate change vulnerability. Special thank you to Bill Reeves, Chief of Biodiversity at TWRA, for his tremendous leadership in confronting the challenge of climate change in fish and wildlife conservation. Thank you to the following individuals who, along with Bill, were actively involved in the application of the Climate Change Vulnerability Index (CCVI) for Tennessee species: Josh Campbell, Bart Carter, Rob Colvin, Pandy English, Terry Hopkins, Don Hubbs, David Sims, Scott Somershoe, and Carl Williams at TWRA; Andrea Biship, Todd Crabtree, David Lincicome, and Roger McCoy at the Tennessee Department of Environment and Conservation Natural Heritage Program; Taylor Hannah at Mississippi State University; Nicholas Hollingshead at Sewanee Environmental Institute; Charles Kwit, Alex Pfenningwerth, and Brian Watson at the University of Tennessee - Knoxville; and David Neely at the University of Tennessee -
Chattanooga. We also sincerely thank Linda Joyce and Curtis Flather of the U.S. Forest Service Rocky Mountain Research Station, who provided invaluable information and insights for the spatial analysis.
Lastly, thank you to Doug Inkley at NWF and Gregg Elliott at K. Gregg Consulting for offering insightful review comments. Funding for this project was provided by a State Wildlife Grant administered by the State of Tennessee.
Suggested citation:
Glick, P., S.R. Palmer, and J.P. Wisby. 2015. Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats. Report prepared by the National Wildlife Federation and The Nature Conservancy
- Tennessee for the Tennessee Wildlife Resources Agency, Nashville, TN.
Cover photos:
Counter clockwise from upper right: Lesser weasel (Mustela nivalis) - GrahamC57, Flickr Creative Commons; red-legged salamander (Plethodon shermani) - Squamatologis, Flickr Creative Commons; Tennessee pigtoe (Plueronaia barnensiana) - Tim Lane, Flickr Creative Commons; Great Smoky Mountains National Park - Matthew Paulson, Flickr Creative Commons; red-headed woodpecker (Melanerpes erythrocephalus) - BiteYourBum.Com Photography, Flickr Creative Commons; yellowbelly watersnake (Nerodia erythrogaster flavigaster) - Greg Schechter, Flickr Creative Commons.
CONTENTS 1
Executive Summary.............................................................................................................................. 1 2
Introduction........................................................................................................................................... 3 2.1 Climate Change Vulnerability Assessments in Brief.................................................................... 4 3
Elements of Exposure: Climate Change in Tennessee.......................................................................... 6 3.1 Historical Climate and Recent Trends........................................................................................... 6 3.2 Projected Future Climate Conditions............................................................................................ 7 4
Putting the Pieces Together: Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats....................................................................................................................................................... 12 4.1 Vulnerability of Tennessee Species............................................................................................ 14 4.1.1 Climate Change Vulnerability Index Assessment for Selected Species of Greatest Conservation Need.............................................................................................................................. 14 4.1.1.1 Brief Overview of the Climate Change Vulnerability Index (CCVI).............................. 14 4.1.1.2 Vulnerability and Conservation Rank............................................................................. 15 4.1.1.3 Approach Used by the Tennessee Team......................................................................... 16 4.1.2 CCVI Assessment Results for Selected Tennessee Species................................................ 17 4.1.2.1 Overall Comparison among Species and Taxonomic Groups......................................... 17 4.1.2.2 Vulnerability by Taxonomic Group................................................................................ 22 4.1.2.2.1 Mammals................................................................................................................... 22 4.1.2.2.2 Birds.......................................................................................................................... 24 4.1.2.2.3 Reptiles...................................................................................................................... 28 4.1.2.2.4 Amphibians............................................................................................................... 30 4.1.2.2.5 Fish............................................................................................................................ 33 4.1.2.2.6 Mussels and Crayfish................................................................................................ 35 4.1.2.2.7 Plants......................................................................................................................... 38 4.1.2.3 Some Cautions When Interpreting CCVI Results........................................................... 41 4.2 Vulnerability of Tennessee Habitats........................................................................................... 43 4.2.1 Terrestrial Habitats.............................................................................................................. 43 4.2.1.1 Shifts in Vegetation......................................................................................................... 43 4.2.1.2 Altered Disturbances....................................................................................................... 44 4.2.1.3 Altered Ecological Processes.......................................................................................... 45 4.2.1.4 Implications for Wildlife................................................................................................. 45 4.2.2 Aquatic Habitats.................................................................................................................. 46
4.2.2.1 Higher Water Temperatures and Altered Water Quality................................................. 46 4.2.2.2 Changes in Hydrology..................................................................................................... 47 4.2.2.3 Wetland Habitat Loss...................................................................................................... 48 4.2.2.4 Implications for Wildlife................................................................................................. 48 4.3 Key Vulnerabilities...................................................................................................................... 49 4.4 Spatial Vulnerability Analysis for Tennessee............................................................................. 50 4.4.1 Overview of Spatial Vulnerability Assessments................................................................. 50 4.4.2 Foundational Maps for Tennessee....................................................................................... 51 4.4.2.1 Terrestrial Habitat Priority Areas.................................................................................... 51 4.4.2.2 Vegetation Change Analysis using the MC2 Dynamic Vegetation Model..................... 52 4.4.2.3 The Terrestrial Climate Stress Index (TCSI)................................................................... 54 4.4.2.4 Resilient Sites for Terrestrial Conservation.................................................................... 56 4.4.3 Overlay Maps for Tennessee............................................................................................... 59 4.4.3.1 Overlay of Terrestrial Habitat Priority Areas and the Modified Terrestrial Climate Stress Index (TCSI)................................................................................................................................... 59 4.4.3.2 Overlay of Terrestrial Habitat Priority Areas and Resilient Sites for Terrestrial Conservation.................................................................................................................................... 60 4.4.3.3 Overlay of the Modified Terrestrial Climate Stress Index and Resilient Sites for Terrestrial Conservation.................................................................................................................. 62 4.4.3.4 Overlay of Terrestrial Habitat Priorities, the Modified Terrestrial Climate Stress Index, and Resilient Sites for Terrestrial Conservation.............................................................................. 64 5
Conclusion........................................................................................................................................... 67 References................................................................................................................................................... 68 Appendix A. Descriptive Tables for the Climate Change Vulnerability Index (CCVI)............................. 77 Appendix B. Direct Exposure Factors for Selected Tennessee Species...................................................... 81 Appendix C. Indirect Exposure and Sensitivity Factors for Selected Tennessee Species........................... 90
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 1 1 EXECUTIVE
SUMMARY
Tennessee is home to a tremendous diversity of ecological systems and native species, representing a rich natural heritage intimately connected to the quality of life for citizens statewide. This diversity, however, will be affected by a changing climate now and in coming decades in a multitude of ways as average temperatures rise and precipitation patterns become more variable and extreme across the state and the Southeast U.S. region. Furthermore, climate change does not occur in isolation but rather acts synergistically with other stressors, exacerbating many of the conservation challenges managers already face.
Developing meaningful strategies to protect the states valued natural resources requires an understanding of the regional and localized impacts of climate change within this broader context. Climate change vulnerability assessments are an important tool for providing natural resource managers with the type of information needed to make informed decisions in an increasingly complex management context.
Accordingly, the Tennessee Wildlife Resources Agency (TWRA) has engaged in a collaborative effort to assess the vulnerability of both species and habitats to help inform its State Wildlife Action Plan (SWAP) and other relevant conservation strategies. The Tennessee assessment focuses on three main areas: species vulnerability, potential vegetation change, and landscape feature resilience.
A significant part of Tennessees effort has been the application of the NatureServe Climate Change Vulnerability Index (CCVI) to a subset of the states species of Greatest Conservation Need (GCN).
Species were selected for the CCVI assessment based on factors such as the species role as an indicator of ecosystem health and the potential susceptibility of its habitat to climate change. State fish, plant, and wildlife experts assessed a total of 189 of its more than 1,400 GCN plant and animal species, including 15 mammals, 51 birds, 17 reptiles, 26 amphibians, 19 fish, 27 freshwater mussels, 8 crayfish, and 26 plants.
Overall, 119 (63%) of the species assessed scored as Presumed Stable or Increase Likely, while 70 (37%) were considered at least Moderately Vulnerable. Mammals, birds, and reptiles (e.g., Indiana bat [Myotis sodalis], American bittern [Botaurus lentiginosus], and Alligator snapping turtle
[Macrochelys temminckii]) comprise most of the species ranked as Presumed Stable or Increase Likely, due in part to their mobility and other factors that enhance their adaptive capacity. Fish, mussels, and plants (e.g., brook trout
[Salvelinus fontinalis], longsolid [Fusconaia subrotunda], and Ruths golden aster [Pityopsis ruthii])
comprised the greatest number of species that ranked as Moderately Vulnerable or above due to a variety of reasons, including existence of natural and anthropogenic barriers to dispersal, restricted habitat range, and high levels of physiological sensitivity to changing temperatures and moisture.
Hellbender (Cryptobrandhus alleganiensis) - Brian Gratwicke, Flickr Creative Commons
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 2 Some of the most-significant impacts of climate change on Tennessees fish and wildlife species will be associated with changes to their habitats. To supplement the CCVI analysis, this report provides a brief summary of the scientific literature highlighting recent and projected changes to terrestrial and aquatic habitats across the state and region. Notable impacts include:
Changes in the composition of associated plant species in both forest and grassland systems, particularly in the western portion of the state; An increase in the frequency and severity of disturbances such as wildfires and outbreaks of already-problematic species such as southern pine beetle (Dendroctonus frontalis Zimmermann) and hemlock wooly adelgid (Adelges tsugae);
Shifts in the location and extent of suitable habitat for fish and other aquatic species due to higher water temperatures and altered water quality, with areas of coldwater habitat likely to decline and warmwater habitat projected to expand; Changes in the timing and magnitude of streamflows and other hydrological conditions, resulting in changes to the physical structure of habitats in streams and increased drying of ephemeral pools important to amphibians and other wildlife.
Tennessees assessment also includes a spatial analysis of climate change vulnerability across terrestrial habitats to help inform land management efforts. The study includes comparisons between Terrestrial Habitat Priority areas identified in the 2015 State Wildlife Action Plan and several established indices of potential climate stress and resilience, including the Terrestrial Climate Stress Index (TCSI) developed by the U.S. Forest Service and areas identified as Resilient Sites for Terrestrial Conservation by The Nature Conservancy (TNC). By overlaying various maps indicating areas of current significance for terrestrial GCN species, potential changes in climatic variables and associated vegetation types, and features such as high geological and topographic diversity and habitat connectivity, managers will be able to identify lands that might be especially important for conservation in an era of climate change. While there is a fair amount of complexity in results across the state depending on the various factors considered, terrestrial habitat priority areas in certain regions, such as the Mississippi Alluvial Plain and parts of the Interior Low Plateau, appear especially vulnerable to climate change compared to other areas, such as the Cumberland Plateau and Mountains and portions of the Blue Ridge.
With a greater understanding of the vulnerability of its species and habitats to changing climate conditions, Tennessee has laid an important foundation to address the challenges of climate change as part of its ongoing efforts to conserve its valued fish and wildlife resources for current and future generations.
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 3 2 INTRODUCTION Recent and projected changes in climate conditions across the nation have galvanized state fish and wildlife agencies to develop strategies to prepare for and cope with associated impacts as part of their State Wildlife Action Plans (SWAP) (Joyce et al. 2008, AFWA 2009, National Fish, Wildlife and Plants Climate Adaptation Partnership 2012). There is growing recognition that, without consideration of climate change, it will become increasingly difficult to achieve the goals of protecting priority habitats and preventing wildlife species from declining to the point of endangerment.
The traditional practice of relying on historical conditions for factors such as average temperatures, precipitation, the timing of streamflows, habitat ranges, and species assemblages will no longer be sufficient as a benchmark or goal for conservation decisions (Stein et al. 2014). As diverse species respond to climate change in different ways, important inter-specific connections - such as between pollinators and the plants they fertilize, or breeding birds and the insects on which they feed - will be broken (Root and Schneider 2006). In addition, studies suggest that climate change will contribute to complete biome changes in some areas (Gonzalez et al. 2010, Staudinger et al. 2013). These and other impacts will pose key challenges for state fish and wildlife management. For example:
The suitable habitat range of target species of fish and wildlife may shift outside of the states borders or disappear altogether (Kelly and Goulden 2008, Loarie et al. 2009, Chen et al.
2011).
Changes in species assemblages and phenological events may alter ecological processes that are fundamental to achieving current conservation goals and objectives (Walther 2010, Blois et al. 2013).
More-intense storms and associated flooding may alter habitats and damage key infrastructure such as fish passage culverts and roads (Karetinov et al. 2008).
Threatened and endangered species may be at increased risk of population declines due to limited adaptive capacity and climate change effects on key habitats (Pearson et al. 2014, Urban 2015).
Impacts outside of the state and region could intensify threats to migratory birds and other migratory species (Small-Lorenz et al. 2013).
As Tennessee strives to conserve its highly-diverse ecosystems and associated fish and wildlife species, addressing the significant risks from climate change is essential.
Flooding after a heavy rainstorm - Lindsey Turner, Flickr Creative Commons
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 4 Tennessee is characterized by considerable variability in topography, climate regimes, and terrestrial vegetation types, which is one of the reasons it happens to be among the most biologically-diverse inland states in the United States (Stein et al. 2000, Dale et al. 2010). These factors alone will mean that the effects of climate change are likely to be complex. Adding to the challenge is the fact that the ecological impacts associated with climate change do not exist in isolation but combine with and exacerbate other stressors on the states and regions natural systems. Indeed, much of Tennessees habitats have already been altered over the last two centuries due to human activities, including urban, industrial, and agricultural development, construction of roads and rail lines, and forestry and water resource practices.
These activities have fragmented and destroyed habitats, restricted river flows, polluted the air and waterways, and contributed to exotic species invasions (TWRA 2005).
Addressing these stresses will become increasingly challenging in an era of climate change, particularly as the states human population continues to grow. Habitat fragmentation, for example, may make it difficult for some species to move to new areas in search of favorable climate conditions. Heavier rainfall events may contribute to greater erosion and polluted runoff from urban and agricultural areas into lakes and streams. Deforestation and grazing in riparian areas may increase exposure of stream systems to higher temperatures and siltation from erosion. As discussed further below, understanding the synergies and linkages among multiple stressors, including climate change, is necessary for the development of a successful fish and wildlife conservation strategy.
Based on projected climate change across the southeastern United States, including Tennessee, this report highlights recent efforts to assess the vulnerability of some of the states wildlife species and habitats. The information presented is intended to help inform the implementation of the Tennessee SWAP, TWRAs Strategic Plan 2014-2020 (TWRA 2014), the Southeast Conservation Adaptation Strategy (SECAS)
(https://griffingroups.com/groups/profile/1500/secas, accessed June 17, 2015), and other relevant conservation strategies.
2.1 CLIMATE CHANGE VULNERABILITY ASSESSMENTS IN BRIEF Climate change vulnerability assessments can provide two essential types of information needed for adaptation planning: 1) identification of which species or ecological systems are likely to be most strongly affected by projected changes, which can help in prioritizing species and habitats that will be the focus of relevant management actions; and 2) an understanding of the specific reasons why those species and habitats are vulnerable, which can inform the development of specific management strategies (Glick et al. 2011, Stein et al. 2014).
Vulnerability to climate change, as it is commonly defined, has three principle components:
- 1. Exposure, which is a measure of how much of a change in climate and associated impacts (e.g.,
changes in hydrology) the target species or system is likely to experience;
- 2. Sensitivity, which is the measure of whether and how a species or system is likely to be affected by or responsive to particular changes in climatic variables and/or related factors; and
- 3. Adaptive capacity, which refers to a species or systems ability to accommodate or cope with change, including both innate and extrinsic characteristics associated with the conservation target.
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 5 Recognizing these individual components is important in that it can help managers more clearly identify the specific factors that contribute to the vulnerability of the species or system being assessed and, in turn, help them to develop relevant adaptation strategies. Because climate change can both exacerbate and be exacerbated by many of the stressors that have long been of concern to fish and wildlife managers, many of these other factors can be brought into the vulnerability assessment process, both directly and indirectly.
It is important to recognize that climate change vulnerability assessments do not dictate which species or habitats to choose as targets for conservation. For example, while a vulnerability assessment can provide a factual underpinning for differentiating between species and systems likely to decline and those likely to thrive, the choice of whether to focus conservation efforts on the most vulnerable, the most viable, or a combination of the two, will of necessity be based on a range of variables. Nor do climate change vulnerability assessments dictate specific management actions to take. Rather, they provide additional information to inform such decisions within the context of broader conservation planning.
There are a variety of tools and methods for conducting climate change vulnerability assessments, including vulnerability indices, quantitative ecological models, spatial analyses of current and predicted distributions, multi-disciplinary models, and expert elicitation processes (Glick et al. 2011, Stein et al.
2014). The choice of which approach or approaches will depend on a range of factors, including the management questions of concern, the types of conservation targets (e.g., species, habitats, ecosystems, etc.), the geographic scope, available data, technical expertise, financial resources, and time constraints.
Often, a combination of approaches, as adopted by Tennessee, will be most effective in informing management decisions (Young et al. 2014).
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 6 3 ELEMENTS OF EXPOSURE: CLIMATE CHANGE IN TENNESSEE Understanding the potential range of species and habitat vulnerabilities to climate change begins with a review of key elements of exposure - specifically temperature and precipitation - and their historic and projected trends. This section highlights recent trends and climate change projections, drawing largely from Third National Climate Assessment for the United States (Kunkel et al. 2013) and data from the Tennessee Climatological Service (https://ag.tennessee.edu/climate/Pages/climatedataTN.aspx, accessed June 17, 2015).
3.1 HISTORICAL CLIMATE AND RECENT TRENDS Historically, the climate of the southeastern United States has been characterized by both interannual and interdecadal variability, and it is influenced by a range of factors, including latitude, topography, and proximity to the oceans (Ingram et al. 2013). Within the state of Tennessee, a diverse topography, in particular, contributes to considerable variation in average conditions, with the lower-lying plains and the Ridge and Valley ecoregion experiencing generally higher average temperatures than the higher-elevation Cumberland Plateau and Great Smoky Mountains (Tennessee Climatological Service 2014). Across the state, average annual temperature varies from 62° F in the extreme southwest to 45° F in the highest peaks to the east. Average temperatures in Tennessee and throughout the southeast region have risen since the early 1970s, although some of this increase is attributed to land use changes (e.g., increased urbanization).
The frequency of minimum temperatures exceeding 75° F also has been increasing across much of the region.
Topography also has an influence on precipitation, with average annual precipitation ranging from 46-55 inches (Tennessee Climatological Service 2014). Over the Cumberland Plateau, average precipitation ranges from 50-55 inches per year. Precipitation is generally highest in the mountainous eastern border with North Carolina, where average precipitation can reach up to 80 inches per year (see Figure 1).
Precipitation is lowest in the northern portion of the Ridge and Valley, which is shadowed by the Great Smoky Mountains to the southeast and Cumberland Plateau to the northwest. Most of the precipitation in Tennessee occurs during winter and early spring due to more frequent large-scale storms. Thunderstorms also contribute to significant precipitation in mid-summer, particularly in the mountains. Prolonged dry spells tend to occur in summer and fall. The Southeast U.S. region also experiences a range of extreme weather events, including heavy rainfall and droughts and extreme heat and cold spells. Severe snow and ice storms can occur as well, particularly across the northern tier, although historically the events have tended to be short-lived.
Variability in precipitation from year to year (e.g., an exceptionally wet summer followed by and exceptionally dry summer) has increased compared to the middle of the 20th century (Groisman and Knight 2008, Wang et al. 2010). In addition, the frequency of extreme precipitation events has risen across the southeastern United States, although the trend has been most pronounced in the lower Mississippi River Valley and the northern Gulf Coast (Kunkel et al. 2013). Average snowfall totals across the northern tier of the southeastern region have declined by 1% per year since the late 1930s, although the frequency of snowstorms has increased since the 1960s (Chagnon et al. 2006).
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 7 Figure 1. Annual average precipitation for the Southeast region using the Parameter-elevation Regressions on Independent Slopes Model (PRISM) (Kunkel et al. 2013).
3.2 PROJECTED FUTURE CLIMATE CONDITIONS Projections of change in climate conditions in Tennessee and across the Southeast in the coming decades vary, depending on the particular climate models and assumptions used, as well as the scenario or scenarios chosen for how much greenhouse gas emissions are expected to change over time. No projection can be considered right or wrong. Determining which projections to consider when planning for climate change depends on many factors, such as: the spatial and temporal scales at which associated management decisions will be made; the availability of regionally-specific data; the level of detail required; the degrees of uncertainty in model results and underlying data; and the level of risk managers are willing to accept in making decisions under uncertainty. For some decisions, more-generalized projections such as changes in average annual temperature and precipitation patterns across a relatively broad region will be sufficient. For other cases, more-detailed, downscaled information may be necessary. Often, observations and expert opinion can augment climate projections.
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 8 This section summarizes general projections for climate change across the Southeast, derived from information developed and compiled for the Third National Climate Assessment (Kunkel et al. 2013).
Primary changes include the following:
Mean annual temperatures are projected to increase across the Southeast through the 21st century.
By 2050, the largest increases (3°F to 5°F) are projected over the interior of the region. The greatest warming is projected to take place in summer months (see Figure 2).
The average annual number of days with maximum temperatures exceeding 95°F is expected to increase across the region.
Overall warming in the northern tier of the region is projected to increase the length of the freeze-free season by as much as 30 days in the mid-21st century, and the number of growing degree days (with a base of 50°F) is expected to increase by nearly 25%.
An increase in interannual precipitation variability is noted across the Southeast through the first half of the 21st century, with the greatest variability projected during the summer season (see Figure 3).
In general, projections for changes in precipitation are less certain than those for temperature. In the short range (i.e., by 2035), projected changes in annual precipitation across the region are smaller than typical year-to-year variations seen in the historical record. By the end of the 21st century, however, annual precipitation is projected to decrease by as much as 12% across Louisiana and Arkansas, with increases of up to 6% across the eastern part of the region, including Tennessee.
The annual number of days with extreme precipitation is expected to increase by the mid-21st century, particularly along the southern Appalachians as well as parts of Tennessee and Kentucky.
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 9 Figure 2. Simulated difference in annual and seasonal mean temperature (°F) for the Southeast region, for 2041-2070 with respect to the reference period of 1971-2000. Hatched areas indicate that the projected changes are significant and consistent among models (Kunkel et al. 2013).
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 10 Figure 3. Simulated difference in annual and seasonal mean precipitation (%) for the Southeast region, for 2041-2070 with respect to the reference period of 1971-2000. Hatched areas indicate that the projected changes are significant and consistent among models (Kunkel et al. 2013).
These changes will have associated impacts on ecological features that may be important for many fish and wildlife species, such as stream hydrology, wildfires, and plant and animal phenology. For example:
Higher temperatures are expected to contribute to an increase in the frequency and intensity of wildfires across the Southeast, including an increase in the total area burned and longer fire seasons. The potential increase in drought frequency also could increase fire risk in some areas.
Climate change affects hydrologic process and water resources directly (i.e., through changes in precipitation, evapotranspiration, groundwater recharge, timing and volume of streamflows, and
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 11 water yield) and indirectly (e.g., through changes in water quality and water use for irrigation and other human uses).
Although there is considerable uncertainty among models in projections for changes in hydrological conditions in the southeastern United States, annual water yield across the region is projected to decline in the first half of the 21st century (see Figure 4).
Figure 4. Mean trends predicted for 2010 to 2060 in mean annual water yield, normalized by the 2001 to 2010 mean annual water yield. Hatched area represents locations where the predicted trend in water yield is statistically significant (p<0.05) (Ingram et al.
2013).
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 12 4 PUTTING THE PIECES TOGETHER: CLIMATE CHANGE VULNERABILITY ASSESSMENT FOR TENNESSEE WILDLIFE AND HABITATS Tennessee has taken a multi-pronged approach to address climate change as part of the development and implementation of its updated State Wildlife Action Plan (SWAP). In 2009, the Tennessee Wildlife Resources Agency (TWRA) compiled the report Climate Change and Potential Impacts to Wildlife in Tennessee, which provides a summary of relevant scientific literature published up to the time on the effects of climate change on a range of habitats and species, including: forests; birds; caves, karst, and bats; nonvolant mammals; and aquatic environments and aquatic life (TWRA 2009). As part of the 2015 comprehensive revision of the SWAP, the agency also put together species and habitat expert teams from several state and federal agencies, academic institutions, and non-governmental organizations to identify and provide additional information needed to assess the vulnerability of relevant conservation targets.
A major emphasis of the species and habitat teams was the application of the NatureServe Climate Change Vulnerability Index (CCVI) (Young et al.
2011) to selected species of greatest conservation need (GCN), as highlighted in Section 4.1 and described in detail in the appendices. In addition, TWRA has worked with The Nature Conservancy (TNC), the National Wildlife Federation (NWF), and the U.S.
Forest Service (USFS) to develop spatial analyses that improve our understanding of where and what types of terrestrial habitats may be most vulnerable to change over time. This information includes maps of climate stress and vegetation change, measured by the USFS Terrestrial Climate Stress Index (TCSI),
and areas of relative landscape vulnerability (and, conversely, resilience), as identified by TNCs Resilient Sites for Terrestrial Conservation methodology (Joyce et al. 2008, USDA Forest Service 2012, USDA Forest Service in press, and Anderson et al. 2014). These different sets of spatial information were also examined along with the 2015 SWAP terrestrial priority areas to determine where in the state different habitats and species populations may be vulnerable to change (see Section 4.4).
As illustrated by Figure 5, these three elements - assessment of species vulnerability using the CCVI; assessment of terrestrial habitat vulnerability comparing the Tennessee Terrestrial Habitat Priority areas and the TCSI; and evaluation of relative vulnerability/resilience based on geophysical settings using the Resilient Sites framework - complete a so-called vulnerability triangle. The focus on these elements Indiana bat (Myotis sodalis) - Andrew King, FWS
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 13 together is intended to provide managers with a more-comprehensive picture of climate change vulnerability by incorporating factors relevant to both species and habitats.
Figure 5. Climate change vulnerability triangle. The three elements of the Tennessee assessment include a focus on species (i.e., the application of the Climate Change Vulnerability Index (CCVI)), terrestrial habitats (i.e., Terrestrial Habitat Priority Areas and projections for climate and vegetation change ranked with the Terrestrial Climate Stress Index (TCSI)), and elements of the states geophysical settings that are likely to be associated with climate resilience in support of biological diversity (i.e.,
areas identified as Resilient Sites for Terrestrial Conservation). Together, these elements provide managers with information on both species-and habitat-related vulnerabilities.
This report highlights the results of the CCVI assessment, briefly summarizes additional information about the vulnerability of associated terrestrial and aquatic habitats based on a review of the literature (as a supplement to the TWRA 2009 report and other sources), and provides an overview of the spatial vulnerability analyses conducted by the team to date.
SPECIES Climate Change Vulnerability Index (CCVI)
HABITATS Vegatation Change/
Terrestrial Climate Stress Index (TCSI) 3 Elements of the Tennessee Assessment GEOPHYSICAL STAGE Resilient Sites for Terrestrial Conservation
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 14 4.1 VULNERABILITY OF TENNESSEE SPECIES 4.1.1 Climate Change Vulnerability Index Assessment for Selected Species of Greatest Conservation Need 4.1.1.1 Brief Overview of the Climate Change Vulnerability Index (CCVI)
The CCVI is a worksheet-based tool designed to facilitate coarse-scale assessments of the potential vulnerability of plant and animal species to climate change within a defined geographic area (Young et al.
2011, Young et al. 2012, Young et al. 2014). The CCVI is especially useful for assessing a large number of species, and it has been widely used by state and federal agencies, non-governmental organizations, and other fish and wildlife practitioners to assist in the development of relevant climate change adaptation strategies (e.g., Byers and Norris 2011, Dubois et al. 2011, Furedi et al. 2011, Schlesinger et al. 2011, Steel et al., 2011, Walk et al. 2011, Bruno et al. 2012, Szabo 2012, Hoving et al. 2013, Ring et al. 2013, Pocewicz et al 2014).
The CCVI (Release 2.1, which is the version used in this analysis) uses a scoring system that integrates projected direct exposure to climate change with three sensitivity factors: 1) indirect exposure to climate change; 2) species-specific sensitivity factors; and 3) documented responses to climate change. The relevance and degree of influence of indirect exposure and sensitivity factors on vulnerability for the species assessed are based on the particular landscape context and generalized natural history characteristics of the species. While more-detailed information about the CCVI is provided in the tables in Appendices A and B and relevant literature cited, key information is summarized in Figure 6 and in the following sections to assist readers in understanding and interpreting the results highlighted herein.
Figure 6. General schematic of the inputs and outputs of the CCVI (Young et al. 2011).
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 15 Sensitivity of a species to climate change is assessed by scoring species against the various indirect exposure and species-specific sensitivity factors, as noted in Tables 13 and 14, respectively, in Appendix A. For each factor, the species is given a numeric score based on a sliding scale from greatly increasing vulnerability (which receives a score of 3), to no effect on vulnerability (which receives a score of 0), to decreasing vulnerability (which receives a score of -2). The indirect exposure and sensitivity results are then combined with direct exposure factors (highlighted in Table 12 of Appendix A and specified for the Tennessee assessment in Appendix B). The numeric sum of these factors is converted into an overall score by comparing it to relevant threshold values. Final vulnerability categories are described below (and in Table 16 of Appendix A):
Extremely Vulnerable (EV): Species abundance and/or range extent within geographical area assessed is extremely likely to substantially decrease or disappear by 2050.
Highly Vulnerable (HV): Species abundance and/or range extent within the geographical area assessed is likely to decrease significantly by 2050.
Moderately Vulnerable (MV): Species abundance and/or range extent within the geographical area assessed is likely to decrease by 2050.
Not Vulnerable/Presumed Stable (PS): Available evidence does not suggest that the species abundance and/or range extent within the geographical area assessed will change (increase/decrease) substantially by 2050. Actual range boundaries may change.
Not Vulnerable/Increase Likely (IL): Available evidence suggests that the species abundance and/or range extent within the geographical area assessed is likely to increase by 2050.
4.1.1.2 Vulnerability and Conservation Rank The CCVI is intended to be used in conjunction with NatureServe conservation status ranks (e.g., Global Rank and State Rank, as defined in Table 1). Because population size, range size, and demographic factors may influence both conservation status and vulnerability to climate change, the CCVI does not explicitly include those factors in its variables for sensitivity. The Global Rank and State Rank thus are not necessarily an indication of climate change vulnerability, as one might have assumed.
Indeed, climate change may pose a new challenge for species that otherwise may be considered stable or common at the global and/or state level (e.g., a species may rank as Extremely Vulnerable but have a conservation ranking of S5). Conversely, it may be that climate change is not significant compared to other stressors that contribute to the species conservation rank. For example, some species may be considered rare or imperiled due to factors such as overharvest, habitat loss, or disease but may not be especially sensitive to changing climate conditions. That said, special attention might be warranted for species that are ranked as both vulnerable to climate change and otherwise imperiled (e.g., have lower S-and/or G-rank scores), as they are likely to have lower adaptive capacity and might be more vulnerable to extreme weather events or other disturbances (Young et al. 2011). Looking at both the vulnerability scores and conservation rank can provide a more-thorough understanding of species conservation status under changing climate conditions (Hoving et al. 2013).
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 16 Table 1. Global and state conservation ranking system for species (TWRA 2005)
Global (G) Rank G1 Critically imperiled globally; 5 or fewer occurrences worldwide G2 Imperiled globally; 6 to 20 occurrences worldwide G3 Very rare or restricted throughout range;21-100 occurrences worldwide G4 Apparently secure globally though locally rare sometimes; 100-1000 occurrences worldwide G5 Demonstrably secure globally; over 1000 occurrences worldwide G?
Uncertain global rank GH Historic global occurrence; possibly extinct GNR Not ranked currently at global level G#Q Questionable taxonomy G#G#
Mixed rank due to uncertainty G#T#
Rank of a subspecies or variety State (S) Rank S1 Critically imperiled in state; 5 or fewer occurrences statewide S2 Imperiled within state; 6-20 occurrences statewide S3 Rare and uncommon in state;20-100 occurrences statewide S4 Apparently secure globally, though locally rare sometimes; 100-1000 occurrences statewide S5 Demonstrably widespread and secure in the state S?
Uncertain state rank SH Historical occurrence in state SNR Not ranked currently at state level SP Potentially occurs in state SR Reported to occur in state SX Believed extirpated from state S#S#
Mixed rank due to uncertainty 4.1.1.3 Approach Used by the Tennessee Team After conducting an exploratory assessment using CCVI for 119 GCN species in western Tennessee to evaluate the potential value in using the tool (Colvin et al. 2013), the TWRA team selected 189 of its GCN species (approximately 12% of the total number) for a full assessment. The choice of which species to assess was based on a range of criteria established by the team. While specific criteria for selecting species varied among the taxonomic groups, the general criteria were comprised of one or more of the following conditions:
The species is limited to a certain region of the state; The species selected may represent other, similar species that could be excluded from the assessment; The species is an indicator of ecosystem health; The species has a measurable habitat distribution in the state; The species has a narrow distribution within its range; The species primary habitat may be sensitive to climate change effects; The species was previously common in the state, and taxonomic splits have made finer distinctions; The species is at the edge of its range in Tennessee; The species has restricted breeding habitat;
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 17 The species is representative of a particular habitat type (e.g., riparian forest, marsh).
4.1.2 CCVI Assessment Results for Selected Tennessee Species 4.1.2.1 Overall Comparison among Species and Taxonomic Groups One way to interpret the results of CCVI assessments is to compare relative vulnerability among the various species and taxonomic groups assessed. Table 2 indicates the final vulnerability scores for each of the species included in the Tennessee study, sorted by the CCVI score, taxonomic group, and species common name. Figure 7 illustrates how those scores compare across the associated taxonomic groups.
Overall, 119 (63%) of the 189 species assessed scored as Presumed Stable or Increase Likely, and 70 (37%) were considered at least Moderately Vulnerable. Mammals, birds, and reptiles comprise most of the species ranked as Presumed Stable or Increase Likely due, in part, to their mobility and other factors that enhance their adaptive capacity. Plants, fish, and mussels comprised the greatest number of species that ranked as Moderately Vulnerable or above for a variety of reasons, including the presence of natural and anthropogenic barriers to dispersal, restricted habitat range, and high levels of sensitivity to changes in temperature and moisture.
It is important to note that the comparison across taxonomic groups should be interpreted only generally, as the species assessed within each taxonomic group were chosen for varying reasons and represent a subset of all Tennessee species within those groups. Comparisons within the specific taxonomic groups and the specific results for the various factors contributing to vulnerability among individual species, as described below and in Appendix C, are likely to be especially useful in identifying potential management responses.
Table 2. CCVI scores for selected Tennessee GCN species Taxonomic Group Scientific Name Common Name CCVI Score Fish Salvelinus fontinalis Brook trout Extremely Vulnerable Fish Acipenser vulvescens Lake sturgeon Extremely Vulnerable Fish Etheostoma boschungi Slackwater darter Extremely Vulnerable Plant Asplenium scolopendrium var. americanum (syn.
Phyllitis scolopendrium var.
americana)
American harts-tongue Extremely Vulnerable Plant Astragalus bibullatus Pynes ground-plum Extremely Vulnerable Plant Hedyotis purpurea var.
montana (syn. Houstonia montana)
Roan Mountain bluet/Venus pride Extremely Vulnerable Plant Gymnoderma lineare Rock gnome lichen Extremely Vulnerable Plant Pityopsis ruthii Ruths golden aster Extremely Vulnerable Plant Paysonia perforate Spring Creek bladderpod Extremely Vulnerable Plant Xyris tennesseensis Tennessee yellow-eyed grass Extremely Vulnerable Plant Helianthus verticillatus Whorled sunflower Extremely Vulnerable Mammal Glaucomys sabrinus coloratus Carolina northern flying squirrel Highly Vulnerable Amphibian Cryptobranchus alleganiensis Hellbender Highly Vulnerable Fish Attractosteus spatula Alligator gar Highly Vulnerable Fish Etheostoma sagitta Arrow darter Highly Vulnerable
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 18 Table 2. CCVI scores for selected Tennessee GCN species Taxonomic Group Scientific Name Common Name CCVI Score Fish Noturus crypticus Chucky madtom Highly Vulnerable Fish Polyodon spathula Paddlefish Highly Vulnerable Mussel Fusconaia subrotunda Longsolid Highly Vulnerable Mussel Villosa vanuxemensis Mountain creekshell Highly Vulnerable Mussel Villosa taeniata Painted creekshell Highly Vulnerable Mussel Toxolasma lividus Purple lilliput Highly Vulnerable Mussel Obovaria subrotunda Round hickorynut Highly Vulnerable Mussel Pleurobema oviforme Tennessee clubshell Highly Vulnerable Plant Solidago spithamaea Blue Ridge goldenrod Highly Vulnerable Plant Boechera perstellata (syn.
Arabis perstellata)
Brauns rockcress Highly Vulnerable Plant Physaria globosa (syn.
Lesquerella globosa)
Shorts bladderpod Highly Vulnerable Plant Geum radiatum Spreading avens/Appalachian avens Highly Vulnerable Plant Spiraea virginiana Virginia spiraea/Virginia meadowsweet Highly Vulnerable Plant Platanthera integrilabia White fringeless orchid/monkey-face orchid Highly Vulnerable Mammal Microtus chrotorrhinus carolinensis Southern rock vole Moderately Vulnerable Bird Scolopax minor American woodcock Moderately Vulnerable Bird Aimophila aestivalis Bachman's sparrow Moderately Vulnerable Reptile Glyptemys muhlenbergii Bog turtle Moderately Vulnerable Amphibian Hyla gratiosa Barking treefrog Moderately Vulnerable Amphibian Gyrinophilius gulolineatus Berry Cave salamander Moderately Vulnerable Amphibian Lithobates areolatus Crawfish frog Moderately Vulnerable Amphibian Hemidactylium scutatum Four-toed salamander Moderately Vulnerable Amphibian Hyla versicolor Gray treefrog Moderately Vulnerable Amphibian Aneides aeneus Green salamander Moderately Vulnerable Amphibian Psedacris brachyphona Mountain chorus frog Moderately Vulnerable Amphibian Desmognathus aeneus Seepage salamander Moderately Vulnerable Amphibian Acris gryllus Southern cricket frog Moderately Vulnerable Amphibian Gyrinophilius palleucus Tennessee cave salamander Moderately Vulnerable Amphibian Plethodon welleri Wellers salamander Moderately Vulnerable Fish Cycleptis elongatus Blue sucker Moderately Vulnerable Fish Carpiodes velifer Highfin carpsucker Moderately Vulnerable Fish Chrosomus saylori Laurel dace Moderately Vulnerable Fish Etheostoma bellum Orangefin darter Moderately Vulnerable Fish Noturus fasciatus Saddled madtom Moderately Vulnerable Fish Clinostomus funduloides Smoky dace Moderately Vulnerable Fish Percina aurantiaca Tangerine darter Moderately Vulnerable Mussel Strophitis connasaugaensis Alabama creekmussel Moderately Vulnerable Mussel Villosa nebulosa Alabama rainbow Moderately Vulnerable Mussel Medionidus conradicus Cumberland moccasinshell Moderately Vulnerable Mussel Alasmidonta marginata Elktoe Moderately Vulnerable Mussel Pleurobema hanleyianum Georgia pigtoe Moderately Vulnerable Mussel Obovaria olivaria Hickorynut Moderately Vulnerable Mussel Villosa lienosa Little spectaclecase Moderately Vulnerable Mussel Pleurobema cordatum Ohio pigtoe Moderately Vulnerable
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 19 Table 2. CCVI scores for selected Tennessee GCN species Taxonomic Group Scientific Name Common Name CCVI Score Mussel Actinonaias pectorosa Pheasantshell Moderately Vulnerable Mussel Pleurobema rubrum Pyramid pigtoe Moderately Vulnerable Mussel Quadrula cylindrica Rabbitsfoot Moderately Vulnerable Mussel Pleuronaia dolabelloides Slabside pearlymussel Moderately Vulnerable Mussel Alasmidonta viridis Slippershell mussel Moderately Vulnerable Mussel Cumberlandia monodonta Spectaclecase Moderately Vulnerable Mussel Lasmigona holstonia Tennessee heelsplitter Moderately Vulnerable Mussel Pleuronaia barnesiana Tennessee pigtoe Moderately Vulnerable Plant Conradina verticillata Cumberland rosemary Moderately Vulnerable Plant Dalea foliosa Leafy prairie-clover Moderately Vulnerable Plant Echinacea tennesseensis Tennessee purple coneflower Moderately Vulnerable Mammal Neotoma magister Allegheny woodrat Presumed Stable Mammal Sorex palustris American water shrew Presumed Stable Mammal Myotis leibii Eastern small-footed bat Presumed Stable Mammal Myotis grisescens Gray bat Presumed Stable Mammal Parascalops breweri Hairy-tailed mole Presumed Stable Mammal Myotis sodalis Indiana bat Presumed Stable Mammal Mustela nivalis Least weasel Presumed Stable Mammal Myotis septentrionalis Northern myotis Presumed Stable Mammal Corynorhinus rafinesquii Rafinesque's big-eared bat Presumed Stable Mammal Tamiasciurus hudsonicus Red squirrel Presumed Stable Mammal Sorex fumeus Smoky shrew Presumed Stable Mammal Condylura cristata Star-nosed mole Presumed Stable Mammal Napaeozapus insignis Woodland jumping mouse Presumed Stable Bird Botaurus lentiginosus American bittern Presumed Stable Bird Pluvialis dominica American golden plover Presumed Stable Bird Anhinga anhinga Anhinga Presumed Stable Bird Riparia riparia Bank swallow Presumed Stable Bird Vireo bellii Bell's vireo Presumed Stable Bird Thryomanes bewickii Bewick's wren Presumed Stable Bird Vermiforma pinus Blue-winged warbler Presumed Stable Bird Sitta pusilla Brown-headed nuthatch Presumed Stable Bird Tryngites subruficollis Buff-breasted sandpiper Presumed Stable Bird Setophaga cerulea Cerulean warbler Presumed Stable Bird Caprimulgus carolinensis Chuck-will's-widow Presumed Stable Bird Ammodramus savannarum Grasshopper sparrow Presumed Stable Bird Wilsonia citrina Hooded warbler Presumed Stable Bird Oporornis formosus Kentucky warbler Presumed Stable Bird Rallus elegans King rail Presumed Stable Bird Chondestes grammacus Lark sparrow Presumed Stable Bird Ixobrychus exilis Least bittern Presumed Stable Bird Egretta caerulea Little blue heron Presumed Stable Bird Lanius ludovicianus Loggerhead shrike Presumed Stable Bird Limosa fedoa Marbled godwit Presumed Stable Bird Parula americana Northern parula Presumed Stable Bird Dendroica discolor Prairie warbler Presumed Stable Bird Protonotaria citrea Prothonotary warbler Presumed Stable Bird Calidris canutus Red knot Presumed Stable Bird Melanerpes erythrocephalus Red-headed woodpecker Presumed Stable Bird Tyrannus forficatus Scissor-tailed flycatcher Presumed Stable
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 20 Table 2. CCVI scores for selected Tennessee GCN species Taxonomic Group Scientific Name Common Name CCVI Score Bird Accipiter striatus Sharp-shinned hawk Presumed Stable Bird Calidris himantopus Stilt sandpiper Presumed Stable Bird Limnothlypis swainsonii Swainson's warbler Presumed Stable Bird Elanoides forficatus Swallow-tailed kite Presumed Stable Bird Bartramia longicauda Upland sandpiper Presumed Stable Bird Pooecetes gramineus Vesper sparrow Presumed Stable Bird Calidris mauri Western sandpiper Presumed Stable Bird Numenius phaeopus Whimbrel Presumed Stable Bird Caprimulgus vociferus Whip-poor-will Presumed Stable Bird Vireo griseus White-eyed vireo Presumed Stable Bird Charadrius wilsonia Wilson's plover Presumed Stable Bird Hylocichla mustelina Wood thrush Presumed Stable Bird Helmitheros vermivorum Worm-eating warbler Presumed Stable Bird Coccyzus americanus Yellow-billed cuckoo Presumed Stable Reptile Plestiodon anthracinus Coal skink Presumed Stable Reptile Terrapene carolina Eastern box turtle Presumed Stable Reptile Herterodon platirhinos Eastern hognose snake Presumed Stable Reptile Ophisaurus attenuatus longicaudus Eastern slender glass lizard Presumed Stable Reptile Clonophis kirtlandii Kirtland's snake Presumed Stable Reptile Nerodia cyclopion Mississippi green watersnake Presumed Stable Reptile Pituophis melanoleucus melanoleucus Northern pine snake Presumed Stable Reptile Virginia striatula Rough earthsnake Presumed Stable Reptile Apalone mutica Smooth softshell turtle Presumed Stable Reptile Crotalus horridus Timber rattlesnake Presumed Stable Reptile Sistrurus miliarius streckeri Western pygmy rattlesnake Presumed Stable Reptile Western Ribbonsnake Western ribbonsnake Presumed Stable Reptile Nerodia erythrogaser flavigaster Yellowbelly watersnake Presumed Stable Amphibian Desmognathus welteri Black Mountain dusky salamander Presumed Stable Amphibian Desmagnatus abditus Cumberland dusky salamander Presumed Stable Amphibian Desmognathus imitator Imitator salamander Presumed Stable Amphibian Plethodon jordani Jordan's red-cheeked salamander Presumed Stable Amphibian Pseudtriton montanus Mud salamander Presumed Stable Amphibian Plethodon montanus Northern gray-cheeked salamander Presumed Stable Amphibian Desmognathus organi Northern pygmy salamander Presumed Stable Amphibian Plethodon shermani Red-legged salamander Presumed Stable Amphibian Desmognathus wrighti Southern pygmy salamander Presumed Stable Amphibian Plethodon richmondi Southern ravine salamander Presumed Stable Amphibian Ambystoma barbouri Streamside salamander Presumed Stable Amphibian Plethodon aureolus Tellico salamander Presumed Stable Amphibian Plethodon wehrlei Wehrle's salamander Presumed Stable Amphibian Plethodon yonahlossee Yonahlossee salamander Presumed Stable Fish Cyprinella caerulea Blue shiner Presumed Stable Fish Etheostoma cervus Chickasaw darter Presumed Stable Fish Etheostoma pyrrhogaster Firebelly darter Presumed Stable
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 21 Table 2. CCVI scores for selected Tennessee GCN species Taxonomic Group Scientific Name Common Name CCVI Score Fish Typhlichthys subterraneus Southern cavefish Presumed Stable Fish Noturus flavipinnis Yellowfin madtom Presumed Stable Mussel Ligumia recta Black sandshell Presumed Stable Mussel Strophitus undulatus Creeper Presumed Stable Mussel Pleurobema sintoxia Round pigtoe Presumed Stable Mussel Villosa vibex Southern rainbow Presumed Stable Mussel Lasmigona complanata White heelsplitter Presumed Stable musse Orconectes pagei Big Sandy crayfish Presumed Stable Crayfish Cambarus bouchardi Big southfork crayfish Presumed Stable Crayfish Orconectes burri Blood River crayfish Presumed Stable Crayfish Barbicambarus cornutus Bottlebrush crayfish Presumed Stable Crustaction Orconectes wrighti Hardin County crayfish Presumed Stable Crayfish Fallicambarus hortoni Hatchie burrowing crayfish Presumed Stable Crayfish Orconectes alabamensis Stateline crayfish Presumed Stable Crayfish Orconectes incomptus Tennessee cave crayfish Presumed Stable Plant Hottonia inflata American featherfoil Presumed Stable Plant Minuartia cumberlandensis (syn. Arenaria cumberlandensis)
Cumberland sandwort/Cumberland stitchwort Presumed Stable Plant Scutellaria montana Large-flowered skullcap Presumed Stable Plant Clematis morefieldii Morefields leatherflower Presumed Stable Plant Buckleya distichophylla Pirate bush Presumed Stable Plant Apios priceana Prices potato bean Presumed Stable Plant Isotria medeoloides Small whorled pagonia/little five leaves Presumed Stable Bird Tyto alba Barn owl Increase Likely Bird Spiza americana Dickcissel Increase Likely Bird Ardea alba Great egret Increase Likely Bird Limosa haemastica Hudsonian godwit Increase Likely Bird Seiurus motacilla Louisiana waterthrush Increase Likely Bird Ictinia mississippiensis Mississippi kite Increase Likely Bird Icterus spurius Orchard oriole Increase Likely Bird Passerina ciris Painted bunting Increase Likely Bird Passerculus sandwichensis Savannah sparrow Increase Likely Reptile Macrochelys temminckii Alligator snapping turtle Increase Likely Reptile Masticophis flagellum Coachwhip Increase Likely Reptile Anolis carolinensis Green anole Increase Likely Plant Helianthus eggertii Eggerts sunflower Increase Likely Plant Panax quinquefolius Ginseng Increase Likely
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 22 Figure 7. Comparison of CCVI vulnerability scores across taxonomic groups.
4.1.2.2 Vulnerability by Taxonomic Group 4.1.2.2.1 Mammals The team included 15 GCN mammals in the state-wide CCVI assessment. As highlighted in Table 3 (sorted by CCVI score and species common name), 12 species were scored as Presumed Stable, which is primarily attributed to the relatively high mobility and few barriers to dispersal among those species (see Figure 8 and Table 18 in Appendix C). The Carolina northern flying squirrel (Glaucomys sabrinus coloratus) scored as Highly Vulnerable due to the existence of natural barriers to dispersal and the species relatively narrow physiological thermal niche within its Tennessee range. Two species, the southern rock vole (Microtus chrotorrhinus carolinensis) and the American water shrew (Sorex palustris), scored as Moderately Vulnerable. Both mammals prefer cool, higher-elevation forest habitats and are likely to be highly sensitive to increasing temperatures. They also face significant natural barriers (e.g.,
their habitats limited to high elevation areas, or sky islands) that limit their ability to move to other areas in search of more climatically-suitable habitat conditions (Laerm et al. 2007, Linzey and NatureServe 2008, USGS 2015).
The five bat species assessed, including Rafineques big-eared bat 0
10 20 30 40 50 60 Mammals Birds Reptiles Amphibians Fish Mollusks/Other Invert Plants Number of Species Included in Assessment Vulnerability Scores across Taxonomic Groups Extremely Vulnerable Highly Vulnerable Moderately Vulnerable Presumed Stable Increase Likely Carolina northern flying squirrel (Glaucomys sabrinus coloratus) - FWS
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 23 (Corynorhinus rafinesquii), gray bat (Myotis grisescens), eastern small-footed bat (Myotis leibii),
northern myotis (Myotis septentrionalis), and Indiana bat (Myotis sodalis), are assumed to have relatively lower sensitivity to climate change given their natural dispersal ability. The least weasel (Mustela nivalis),
which prefers early successional habitats, could benefit from an increase of these habitats after wildfires or other disturbances. Confidence in results was very high for all species assessed.
Table 3. Conservation status and CCVI score for selected Tennessee GCN mammals Scientific Name Common Name Relative Range Global Rank State Rank CCVI Score Glaucomys sabrinus coloratus Carolina northern flying squirrel East/west edge of range G5T2 S1S2 Highly Vulnerable Sorex palustris American water shrew Southern edge of range G5 S2 Moderately Vulnerable Microtus chrotorrhinus carolinensis Southern rock vole Southern edge of range G4T3 S2 Moderately Vulnerable Neotoma magister Allegheny woodrat Southern edge of range G3G4 S3 Presumed Stable Myotis leibii Eastern small-footed bat Southern edge of range G1G3 S2S3 Presumed Stable Myotis grisescens Gray bat Center of range G3 S2 Presumed Stable Parascalops breweri Hairy-tailed mole Southern edge of range G5 S3 Presumed Stable Myotis sodalis Indiana bat Southern edge of range G2 S1 Presumed Stable Mustela nivalis Least weasel Southern edge of range G5 S2 Presumed Stable Myotis septentrionalis Northern myotis Southern edge of range G2G3 S4 Presumed Stable Corynorhinus rafinesquii Rafinesque's big-eared bat Center of range G3G4 S3 Presumed Stable Tamiasciurus hudsonicus Red squirrel Southern edge of range G5 S4S5 Presumed Stable Sorex fumeus Smoky shrew Southern edge of range G5 S4 Presumed Stable Condylura cristata Star-nosed mole Southern edge of range G5 S2 Presumed Stable Napaeozapus insignis Woodland jumping mouse Southern edge of range G5 S4 Presumed Stable
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 24 Figure 8. Primary CCVI sensitivity factors for selected Tennessee mammals. The x-axis indicates the average CCVI score for relevant indirect exposure and sensitivity factors among all mammals assessed (see Tables 13 and 14 in Appendix A for detailed descriptions). Negative numbers indicate factors that decrease vulnerability, positive scores reflect increased vulnerability.
Factors with a 0 average score are not included in the chart, although it is important to recognize that these are average scores -
in some cases, individual factors that contribute to vulnerability might be offset by factors that decrease vulnerability.
Accordingly, this chart should be seen as supplemental to Table 18 in Appendix C.
4.1.2.2.2 Birds The majority (49) of the 51 GCN birds included in the CCVI study for Tennessee were assessed as Presumed Stable or Increase Likely (see Table 4). The primary reason for this is that the relatively high dispersal ability of birds are likely to provide them with greater capacity to adapt to changes in climate conditions at a broader landscape scale than less-mobile species (see Figure 9, below, and Table 19 in Appendix C). It is important to recognize, however, that the CCVI tool is generally used to assess species within a fixed geographic range. For highly-migratory species, such as many birds, habitat needs may well span beyond the local, state, or regional boundaries considered in the CCVI assessment. Accordingly, some birds may well be vulnerable to climate change and associate impacts in other parts of their broader habitat range (Small-Lorenz et al.
2013).
-0.8
-0.6
-0.4
-0.2 0
0.2 0.4 0.6 0.8 1
Natural Barriers Anthropogenic Barriers Dispersal and Movement Historical Thermal Niche Physiological Thermal Niche Physiological Hydrological Niche Restricted Habitat Features Dietary Versatility Other Interspecific Interaction AVERAGE SENSITIVITY SCORE Primary Sensitivity Factors for Selected Tennessee Mammals American woodcock (Scolopax minor) - FWS
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 25 Only two species, American woodcock (Scolopax minor) and Bachmans sparrow (Aimophila aestivalis),
ranked as Moderately Vulnerable. Both of these ground-nesting birds rely on early-successional habitat for breeding, nesting, and foraging (Meyer 2006, Innes 2010). For instance, Bachmans sparrow is a habitat specialist endemic to longleaf pine forests, and requires open pine stands with little to no midstory, and a dense, herbaceous understory dominated by grasses (Colvin et al. 2013). An increase in the frequency and extent of wildfires in Tennessee due to warmer, drier conditions could alter habitat conditions for foraging and nesting. On the other hand, the potential for climate change to contribute to an expansion of open shrub and grassland habitat in parts of the state, it could be favorable for the birds (Kelley and Williamson 2008). For those species ranked as Increase Likely, a number of factors may be at play. In particular, the barn owl (Tyto alba), scissor-tailed flycatcher (Tyrannus forficatus), and Louisiana waterthrush (Seiurus motacilla) may benefit from relatively high dispersal ability, heat tolerance, and dietary versatility. The barn owl, for instance, is known for its large home range and wide natal dispersion (Colvin et al. 2013). Confidence in index results was very high for all species except American woodcock, for which it was considered low.
Table 4. Conservation status and CCVI score for selected Tennessee GCN birds Scientific Name Common Name Relative Range Global Rank State Rank CCVI Score Scolopax minor American woodcock Entire range G5 S4B Moderately Vulnerable Aimophila aestivalis Bachman's sparrow Entire range G3 S2 Moderately Vulnerable Botaurus lentiginosus American bittern Northern edge of range G4 S1 Presumed Stable Pluvialis dominica American golden plover Entire range G5 S1 Presumed Stable Anhinga anhinga Anhinga Southern edge of range G5 S1B Presumed Stable Riparia riparia Bank swallow Entire range G5 S3 Presumed Stable Vireo bellii Bell's vireo East/west edge of range G5 SHB Presumed Stable Thryomanes bewickii Bewick's wren East/west edge of range G5 S1 Presumed Stable Vermiforma pinus Blue-winged warbler Entire range G5 S4 Presumed Stable Sitta pusilla Brown-headed nuthatch Entire range G5 S2B Presumed Stable Tryngites subruficollis Buff-breasted sandpiper Entire range G4 S3N Presumed Stable Setophaga cerulea Cerulean warbler Entire range G4 S3B Presumed Stable Caprimulgus carolinensis Chuck-will's-widow Entire range G5 S3S4 Presumed Stable Ammodramus savannarum Grasshopper sparrow Entire range G5 S4 Presumed Stable Wilsonia citrina Hooded warbler Entire range G5 S4 Presumed Stable Oporornis formosus Kentucky warbler Entire range G5 S4 Presumed Stable
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 26 Table 4. Conservation status and CCVI score for selected Tennessee GCN birds Scientific Name Common Name Relative Range Global Rank State Rank CCVI Score Rallus elegans King rail Entire range G4 S2 Presumed Stable Chondestes grammacus Lark sparrow Entire range G5 S1B Presumed Stable Ixobrychus exilis Least bittern Entire range G5 S2B Presumed Stable Egretta caerulea Little blue heron Entire range G5 S2B S3N Presumed Stable Lanius ludovicianus Loggerhead shrike Entire range G4 S3 Presumed Stable Limosa fedoa Marbled godwit Entire range G5 N2BN3N Presumed Stable Parula americana Northern parula Entire range G5 S5 Presumed Stable Dendroica discolor Prairie warbler Entire range G5 S3 S4 Presumed Stable Protonotaria citrea Prothonotary warbler Entire range G5 S4 Presumed Stable Calidris canutus Red knot Entire range G4 S2N Presumed Stable Melanerpes erythrocephalus Red-headed woodpecker Entire range G5 S4 Presumed Stable Tyrannus forficatus Scissor-tailed flycatcher Entire range G5 S1B Presumed Stable Accipiter striatus Sharp-shinned hawk Entire range G5 S3B Presumed Stable Calidris himantopus Stilt sandpiper Entire range G5 S3N Presumed Stable Limnothlypis swainsonii Swainson's warbler East/west edge of range G4 S3 Presumed Stable Elanoides forficatus Swallow-tailed kite Entire range G5 N2BN3N Presumed Stable Bartramia longicauda Upland sandpiper Entire range G5 SNA Presumed Stable Pooecetes gramineus Vesper sparrow Entire range G5 S1BS4N Presumed Stable Calidris mauri Western sandpiper Entire range G5 S4N Presumed Stable Numenius phaeopus Whimbrel Entire range G5 N2BN3N Presumed Stable Caprimulgus vociferus Whip-poor-will Entire range G5 S3S4 Presumed Stable Vireo griseus White-eyed vireo Entire range G5 S4 Presumed Stable Charadrius wilsonia Wilson's plover Entire range G5 N2B,N3I nc Presumed Stable Hylocichla mustelina Wood thrush Entire range G5 S4 Presumed Stable Helmitheros vermivorum Worm-eating warbler Entire range G5 S4 Presumed Stable
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 27 Table 4. Conservation status and CCVI score for selected Tennessee GCN birds Scientific Name Common Name Relative Range Global Rank State Rank CCVI Score Coccyzus americanus Yellow-billed cuckoo Entire range G5 S4S5 Presumed Stable Tyto alba Barn owl Entire range G5 S3 Increase Likely Spiza americana Dickcissel Entire range G5 S4 Increase Likely Ardea alba Great egret Entire range G5 S2BS3N Increase Likely Limosa haemastica Hudsonian godwit Entire range G4 N2BN3N Increase Likely Seiurus motacilla Louisiana waterthrush Entire range G5 S4 Increase Likely Ictinia mississippiensis Mississippi kite East/west edge of range G5 S2 S3 Increase Likely Icterus spurius Orchard oriole Entire range G5 S4 Increase Likely Passerina ciris Painted bunting East/west edge of range G5 S2 Increase Likely Passerculus sandwichensis Savannah sparrow Entire range G5 S1B S4N Increase Likely Figure 9. Primary CCVI sensitivity factors for selected Tennessee birds. The x-axis indicates the average CCVI score for relevant indirect exposure and sensitivity factors among all birds assessed (see Tables 13 and 14 in Appendix A for detailed descriptions).
Negative numbers indicate factors that decrease vulnerability, positive scores reflect increased vulnerability. Factors with a 0 average score are not included in the chart, although it is important to recognize that these are average scores - in some cases, individual factors that contribute to vulnerability might be offset by factors that decrease vulnerability. Accordingly, this chart should be seen as supplemental to Table 19 in Appendix C.
-2
-1.5
-1
-0.5 0
0.5 1
1.5 Dispersal/Movement Disturbance Ice and snow Rarity of Physical Habitat Dependence on Other Species for Habitat Diet Specialization Documented Phenological Response AVERAGE SENSITIVITY SCORE Primary Sensitivity Factors for Selected Tennessee Birds
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 28 4.1.2.2.3 Reptiles A total of 17 GCN reptile species were included in the state-wide CCVI assessment (see Table 5). Of those, 13 species were assessed as Presumed Stable. Three species, including coachwhip (Masticophis flagellum), green anole (Anolis carolinensis), and alligator snapping turtle (Macrochelys temminckii) were assessed as Increase Likely. The alligator snapping turtle is not considered vulnerable to climate change and could, in fact, benefit given its ability to burrow in deep aquatic holes within rivers and creeks or in deep, open water, all of which can serve as refugia from unfavorable environmental conditions (Howey and Dinkelacker 2009).
Green anole and coachwhip both seem to prefer warmer temperatures and have relatively-generalized habitat needs. The bog turtle (Glyptemys muhlenbergii) was the only species identified as Moderately Vulnerable to climate change, primarily due to its relatively-narrow habitat requirements (i.e., reliance on bogs and seeps) as well as its dependence on other species to generate habitat. The species has also been found to have relatively-low genetic diversity among its populations, which may limit its adaptive capacity over time (Rosenbaum et al. 2007).
Figure 10, below, and Table 20 in Appendix C highlight the primary factors contributing to vulnerability for the reptile group, based on average sensitivity scores. Limited dispersal capabilities and the existence of anthropogenic barriers were the primary factors increasing vulnerability. On the other hand, several species appear to favor temperatures at the higher end of their physiological niche, and historical exposure to variability in precipitation and moisture regimes may indicate a certain amount of adaptive capacity.
Confidence in results was very high for all species assessed.
Table 5. Conservation status and CCVI score for selected Tennessee GCN reptiles Scientific Name Common Name Relative Range Global Rank State Rank CCVI Score Glyptemys muhlenbergii Bog turtle Southern edge of range G3 S1 Moderately Vulnerable Plestiodon anthracinus Coal skink East/west edge of range G5 S1 Presumed Stable Terrapene carolina Eastern box turtle East/west edge of range G5 S4 Presumed Stable Heterodon platirhinos Eastern hognosed snake East/west edge of range G5 S4 Presumed Stable Ophisaurus attenuatus longicaudus Eastern slender glass lizard East/west edge of range G5T5 S3 Presumed Stable Clonophis kirtlandii Kirtland's snake Southern edge of range G2 S1 Presumed Stable Bog turtle (Glyptemys muhlenbergii) - FWS
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 29 Nerodia cyclopion Mississippi green watersnake East/west edge of range G5 S2 Presumed Stable Pituophis melanoleucus melanoleucus Northern pinesnake East/west edge of range G4T4 S3 Presumed Stable Virginia striatula Rough earth snake East/west edge of range G5 S2S3 Presumed Stable Apalone mutica Smooth softshell turtle East/west edge of range G5 S4 Presumed Stable Crotalus horridus Timber rattlesnake Center of range G4 S4 Presumed Stable Sistrurus miliarius streckeri Western pygmy rattlesnake East/west edge of range G5T5 S2S3 Presumed Stable Thamnophis proximus Western ribbonsnake East/west edge of range G5 S4 Presumed Stable Nerodia erythrogaster flavigaster Yellowbelly watersnake East/west edge of range G5T5 HYB Presumed Stable Macrochelys temminckii Alligator snapping turtle East/west edge of range G3G4 S2S3 Increase Likely Masticophis flagellum Coachwhip Northern edge of range G5 S2 Increase Likely Anolis carolinensis Green anole Northern edge of range G5 S3 Increase Likely Figure 10. Primary CCVI sensitivity factors for selected Tennessee reptiles. The x-axis indicates the average CCVI score for relevant indirect exposure and sensitivity factors among all reptiles assessed (see Tables 13 and 14 in Appendix A for detailed descriptions). Negative numbers indicate factors that decrease vulnerability, positive scores reflect increased vulnerability.
Factors with a 0 average score are not included in the chart, although it is important to recognize that these are average scores -
in some cases, individual factors that contribute to vulnerability might be offset by factors that decrease vulnerability.
Accordingly, this chart should be seen as supplemental Table 20 in Appendix C.
-0.8
-0.6
-0.4
-0.2 0
0.2 0.4 0.6 0.8 Natural Barriers Anthropogenic Barriers Dispersal/Movement Physiological Thermal Niche Historical Hydrological Niche Physiological Hydrological Niche Dependence on Other Species for habitat Documented Genetic Variation AVERAGE SENSITIVITY SCORE Primary Sensitivity Factors for Selected Tennessee Reptiles
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 30 4.1.2.2.4 Amphibians 26 of Tennessees GCN amphibians were included in the state-wide CCVI assessment (see Table 6). Of the total amphibians, 14 species were found to be in the Presumed Stable category. Eleven species, including Berry Cave salamander (Gyrinophilus gulolineatus), barking tree frog (Hyla gratiosa), crawfish frog (Lithobates areolatus), four-toed salamander (Hemidactylium scutatum), gray treefrog (Hyla versicolor), green salamander (Aneides aeneus),
mountain chorus frog (Psedacris brachyphona),
seepage salamander (Desmognathus aeneus),
southern cricket frog (Acris gryllus), Tennessee cave salamander (Gyrinophilus palleucus), and Wellers salamander (Plethodon welleri), were Moderately Vulnerable. One species, hellbender (Cryptobranchus alleganiensis), was found to be Highly Vulnerable.
Table 6. Conservation status and CCVI score for selected Tennessee GCN amphibians Scientific Name Common Name Relative Range Global Rank State Rank CCVI Score Cryptobranchus alleganiensis Hellbender Center of range G3G4 S3 Highly Vulnerable Hyla gratiosa Barking treefrog Center of range G5 S3 Moderately Vulnerable Gyrinophilus gulolineatus Berry Cave salamander Entire range G1Q S2 Moderately Vulnerable Lithobates areolatus Crawfish frog Center of range G5 S3 Moderately Vulnerable Hemidactylium scutatum Four-toed salamander East/west edge of range G5 S3 Moderately Vulnerable Hyla versicolor Gray treefrog East/west edge of range G5 S5 Moderately Vulnerable Aneides aeneus Green salamander Center of range G3G4 S3S4 Moderately Vulnerable Psedacris brachyphona Mountain chorus frog Center of range G5 s4 Moderately Vulnerable Desmognathus aeneus Seepage salamander Center of range G3G4 S1 Moderately Vulnerable Acris gryllus Southern cricket frog Northern edge of range G5 S4 Moderately Vulnerable Gyrinophilus palleucus Tennessee cave salamander Center of range G2G3 S2 Moderately Vulnerable Plethodon welleri Weller's salamander Center of range G3 S2 Moderately Vulnerable Desmognathus welteri Black Mountain dusky salamander Southern edge of range G4 S3 Presumed Stable Barking treefrog (Hyla gratiosa) - USGS
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 31 Table 6. Conservation status and CCVI score for selected Tennessee GCN amphibians Scientific Name Common Name Relative Range Global Rank State Rank CCVI Score Desmagnatus abditus Cumberland dusky salamander Entire range G2G3 S2S3 Presumed Stable Desmognathus imitator Imitator salamander Center of range G3G4 S3 Presumed Stable Plethodon jordani Jordan's red-cheeked salamander Center of range G4 S2S3 Presumed Stable Pseudtriton montanus Mud salamander Center of range G5 S5 Presumed Stable Plethodon montanus Northern gray-cheeked salamander Center of range G4 S3 Presumed Stable Desmognathus organi Northern pygmy salamander Center of range G3 SNR Presumed Stable Plethodon shermani Red-legged salamander Center of range G3 S2 Presumed Stable Desmognathus wrighti Southern pygmy salamander Center of range G3 S3S3 Presumed Stable Plethodon richmondi Southern ravine salamander Center of range G5 S3 Presumed Stable Ambystoma barbouri Streamside salamander Southern edge of range G4 S2 Presumed Stable Plethodon aureolus Tellico salamander Center of range G2G3 S2 Presumed Stable Plethodon wehrlei Wehrle's salamander Southern edge of range G4 S1 Presumed Stable Plethodon yonahlossee Yonahlossee salamander Center of range G4 S2 Presumed Stable Figure 11 shows average sensitivity scores for all of the amphibians included in the Tennessee CCVI analysis (see Table 21 in Appendix C for more detail). For amphibians as a group, the two factors most associated with increased vulnerability to climate change were species physiological dependence on a relatively narrow precipitation/hydrological regime and limited dispersal ability due to both natural and anthropogenic factors, a result supported by recent literature (e.g., Blaustein et al. 2010, Milanovich et al.
2010, Barrett et al. 2014).
One of the most significant factors in the vulnerability of some species is their reliance on ephemeral pools for reproduction. Both the timing and duration of a wetlands hydroperiod (i.e., the period during which a wetland is saturated) are highly correlated with the breeding behavior and reproductive success of many amphibians (Carey and Alexander 2003, Walls et al. 2013). If projected changes in precipitation and increased evaporation associated with higher temperatures contribute to a decline in the quality and/or availability of those pools, the reproductive success of some species (e.g., mountain chorus frog, barking treefrog, gray treefrog, southern cricket frog, and four-toed salamander), could decline. The hellbender is considered Highly Vulnerable due to sensitivity to elevated stream temperatures and reduced flows.
The one factor that reduced vulnerability for many of the species assessed was their exposure to past variations in precipitation, which may indicate that, despite their specific physiological hydrological needs, they might exhibit some adaptive capacity to deal with greater variability in precipitation.
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 32 However, the region is projected to experience greater extremes in temperatures and precipitation, which could exceed some species adaptive capacity. Moreover, summer months are likely to see the greatest increases in average temperatures (Figure 2, above) and declines in average precipitation (Figure 3),
which would lead to earlier drying of ephemeral pools, possibly before maturation into terrestrial forms.
For all species assessed, confidence in the information was considered very high.
Figure 11. Primary sensitivity factors for selected Tennessee amphibians. The x-axis indicates the average CCVI score for relevant indirect exposure and sensitivity factors among all amphibians assessed (see Tables 13 and 14 in Appendix A for detailed descriptions). Negative numbers indicate factors that decrease vulnerability, positive scores reflect increased vulnerability. Factors with a 0 average score are not included in the chart, although it is important to recognize that these are average scores - in some cases, individual factors that contribute to vulnerability might be offset by factors that decrease vulnerability. Accordingly, this chart should be seen as supplemental to Table 21 in Appendix C.
-1
-0.5 0
0.5 1
1.5 Natural Barriers Anthropogenic Barriers Dispersal/Movement Historical Thermal Niche Physiological Thermal Niche Historical Hydrological Niche Physiological Hydrological Niche Rarity of Physical Habitat Dependence on Other Species Diet Specialization AVERAGE SENSITIVITY SCORE Primary Sensitivity Factors for Selected Tennessee Amphibians
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 33 4.1.2.2.5 Fish Among all of the taxonomic groups included in the CCVI assessment for Tennessee, fish species were found to be the most vulnerable to climate change (see Table 7). Of the 19 species included in the state-wide assessment, three were found to be Extremely Vulnerable: brook trout (Salvelinus fontinalis), lake sturgeon (Acipenser fulvescens), and slackwater darter (Etheostoma boschungi). The primary reasons for their vulnerability varies (see Figure 12, below, and Table 22 in Appendix C). For brook trout, a major factor is the species narrow thermal niche and reliance on specific hydrologic conditions (e.g., timing and extent of streamflows) that could be altered with climate change (Clark et al.
2001). Tennessee is also at the southern edge of the species range, which likely means it is already close to its upper thermal tolerance level in the region. Anthropogenic barriers to dispersal and sensitivity to changes in the timing of hydrologic and temperature conditions required for successful spawning are major factors determining the vulnerability of both lake sturgeon and slackwater darter. Species that rely on headwater habitat, such as slackwater darter, are also vulnerable given limited ability to migrate farther upstream to find cooler temperatures (TWRA 2009).
Four species were found to be Highly Vulnerable to climate change: alligator gar (Attractosteus spatula),
arrow darter (Etheostoma sagitta), chucky madtom (Notorus crypticus), and paddlefish (Polyodon spathula). Common factors contributing to the vulnerability of these species include presence of natural and anthropogenic barriers and sensitivity due to limited physiological hydrological niche. The presence of dikes, for example, restrict access of the fish to floodplains for spawning. In addition, increasing coal and gas production activities are expected to lead to more roads and culverts, which also may reduce habitat connectivity.
Confidence for the CCVI results was considered low for blue sucker (Cycleptis elongates) and highfin carpsucker (Carpiodes velifer), moderate for laurel dace (Chrosomus saylori) and paddlefish, and high or very high for all other species assessed.
Table 7. Conservation status and CCVI score for selected Tennessee GCN fish Scientific Name Common Name Relative Range Global Rank State Rank CCVI Score Salvelinus fontinalis Brook trout Southern edge of range G5 S3 Extremely Vulnerable Acipenser fulvescens Lake sturgeon Southern edge of range G3G4 S1 Extremely Vulnerable Lake sturgeon (Acipenser fulvescens) - FWS
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 34 Table 7. Conservation status and CCVI score for selected Tennessee GCN fish Scientific Name Common Name Relative Range Global Rank State Rank CCVI Score Etheostoma boschungi Slackwater darter Northern edge of range G1 S1 Extremely Vulnerable Attractosteus spatula Alligator gar East/west edge of range G3 S1 Highly Vulnerable Etheostoma sagitta Arrow darter Southern edge of range G3G4 S2 Highly Vulnerable Noturus crypticus Chucky madtom Entire range G2 S2 Highly Vulnerable Polyodon spathula Paddlefish Center of range G4 S3 Highly Vulnerable Cycleptis elongatus Blue sucker East/west edge of range G3 S2 Moderately Vulnerable Carpiodes velifer Highfin carpsucker Center of range G4G5 S2S3 Moderately Vulnerable Chrosomus saylori Laurel dace Entire range G1G2 S1 Moderately Vulnerable Etheostoma bellum Orangefin darter Southern edge of range G4G5 S3 Moderately Vulnerable Noturus fasciatus Saddled madtom Entire range G2 S2 Moderately Vulnerable Clinostomus funduloides Smoky dace Northern edge of range G5 S1 Moderately Vulnerable Percina aurantiaca Tangerine darter Center of range G4 S3 Moderately Vulnerable Cyprinella caerulea Blue shiner Northern edge of range G2 S1 Presumed Stable Etheostoma cervus Chickasaw darter Entire range G2 S2 Presumed Stable Etheostoma pyrrhogaster Firebelly darter Southern edge of range G2 S2 Presumed Stable Typhlichthys subterraneus Southern cavefish Center of range G4 S3 Presumed Stable Noturus flavipinnis Yellowfin madtom Center of range G1 S1 Presumed Stable
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 35 Figure 12. Primary CCVI sensitivity factors for selected Tennessee fish. The x-axis indicates the average CCVI score for relevant indirect exposure and sensitivity factors among all fish assessed (see Tables 13 and 14 in Appendix A for detailed descriptions).
Negative numbers indicate factors that decrease vulnerability, positive scores reflect increased vulnerability. Factors with a 0 average score are not included in the chart, although it is important to recognize that these are average scores - in some cases, individual factors that contribute to vulnerability might be offset by factors that decrease vulnerability. Accordingly, this chart should be seen as supplemental to Table 22 in Appendix C.
4.1.2.2.6 Mussels and Crayfish The assessment team selected 27 of Tennessees freshwater mussels and eight crayfish species for inclusion in the CCVI analysis. Mussels in this taxonomic group show relatively high vulnerability to climate change. Among the mussels studied, 16 species ranked as Moderately Vulnerable, and six Highly Vulnerable (see Table 8). Just five species were Presumed Stable. For both Moderately and Highly Vulnerable species, the primary factors contributing to their vulnerability include anthropogenic barriers, implications from human response to climate change (e.g., dredging streams in response to drought conditions), limited dispersal ability given their sessile characteristic, and the dependence on other species (fish) for propagule dispersal, some species of which also may be vulnerable to climate change (see Figure 13, below, and Table 23 in Appendix C). For those species ranked as Presumed Stable, it appears that relative flexibility in terms of propagule dispersal is a primary factor.
Table 8. Conservation status and CCVI score for selected Tennessee GCN mussels Scientific Name Common Name Relative Range Global Rank State Rank CCVI Score Fusconaia subrotunda Longsolid Southern edge G3 S3 Highly Vulnerable Villosa vanuxemensis Mountain creekshell Center of range G4 S4 Highly Vulnerable Villosa taeniata Painted creekshell Center of range G3 S3S4 Highly Vulnerable Toxolasma lividus Purple lilliput Center of range G3 S1S2 Highly Vulnerable 0
0.2 0.4 0.6 0.8 1
1.2 1.4 Natural Barriers Anthropogenic Barriers Human Response to Climate Change Dispersal/Movement Physiological Thermal Niche Physiological Hydrological Niche Disturbance Rarity of Physical Habitat Diet Specialization Depencence on Other Species Interaction Past Genetic Bottleneck Documented Phenological Response AVERAGE SENSITIVITY SCORE Primary Sensitivity Factors for Selected Tennessee Fish
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 36 Table 8. Conservation status and CCVI score for selected Tennessee GCN mussels Scientific Name Common Name Relative Range Global Rank State Rank CCVI Score Obovaria subrotunda Round hickorynut Center of range G4 S2S3 Highly Vulnerable Pleurobema oviforme Tennessee clubshell Center of range G2G3 S2S3 Highly Vulnerable Strophitis connasaugaensis Alabama creekmussel Northern edge G3 S1 Moderately Vulnerable Villosa nebulosa Alabama rainbow Northern edge G3 S2 Moderately Vulnerable Medionidus conradicus Cumberland moccasinshell Center of range G3G4 S3 Moderately Vulnerable Alasmidonta marginata Elktoe Southern edge G4 S4 Moderately Vulnerable Pleurobema hanleyianum Georgia pigtoe Northern edge G1 S1 Moderately Vulnerable Obovaria olivaria Hickorynut Northern edge G4 S2 Moderately Vulnerable Villosa lienosa Little spectaclecase Entire range G5 S4 Moderately Vulnerable Pleurobema cordatum Ohio pigtoe Entire range G4 S3 Moderately Vulnerable Actinonaias pectorosa Pheasantshell Center of range G4 S4 Moderately Vulnerable Pleurobema rubrum Pyramid pigtoe Southern edge G2 S1 Moderately Vulnerable Quadrula cylindrica Rabbitsfoot East/west edge G3 S3 Moderately Vulnerable Pleuronaia dolabelloides Slabside pearlymussel Entire range G2 S2 Moderately Vulnerable Alasmidonta viridis Slippershell mussel Southern edge G4G5 S3S4 Moderately Vulnerable Cumberlandia monodonta Spectaclecase Center of range G3 S2 Moderately Vulnerable Lasmigona holstonia Tennessee heelsplitter Center of range G3 S2 Moderately Vulnerable Pleuronaia barnesiana Tennessee pigtoe Center of range G2G3 S2S3 Moderately Vulnerable Ligumia recta Black sandshell East/west edge G4 S5 Presumed Stable Strophitus undulatus Creeper Southern edge G5 S5 Presumed Stable Pleurobema sintoxia Round pigtoe Southern edge G4 S4 Presumed Stable Villosa vibex Southern rainbow Southern edge G5 S2 Presumed Stable Lasmigona complanata White heelsplitter Entire range G5 S?
Presumed Stable
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 37 Figure 13. Primary CCVI sensitivity factors for selected Tennessee mussels. The x-axis indicates the average CCVI score for relevant indirect exposure and sensitivity factors among all mussels assessed (see Tables 12 and 13 in Appendix A for detailed descriptions). Negative numbers indicate factors that decrease vulnerability, positive scores reflect increased vulnerability.
Factors with a 0 average score are not included in the chart, although it is important to recognize that these are average scores -
in some cases, individual factors that contribute to vulnerability might be offset by factors that decrease vulnerability.
Accordingly, this chart should be seen as supplemental to Table 23 in Appendix C.
The crayfish species assessed (Table 9) were all ranked Presumed Stable, although several species, including stateline crayfish (Orconectes alabamensis), Hardin County crayfish (Orconectes wrighti),
Hatchie burrowing crayfish (Fallicambarus hortoni), and Tennessee cave crayfish (Orconectes incomptus) are sensitive to changing hydrologic conditions, and species with relatively limited distributions are likely to be more vulnerable than those with broader latitudinal ranges (see Figure 14, below, and Table 23 in Appendix C). Confidence in index results for all species was very high for all species assessed in this category.
Table 9. Conservation status and CCVI score for selected Tennessee GCN crayfish Scientific Name Common Name Relative Range Global Rank State Rank CCVI Score Orconectes pagei Big Sandy crayfish Northern edge G2 S1 Presumed Stable Cambarus bouchardi Big southfork crayfish Southern edge G2G3 S1 Presumed Stable Orconectes burri Blood River crayfish Northern edge G2 S2 Presumed Stable Barbicambarus cornutus Bottlebrush crayfish Southern edge G4 S2 Presumed Stable Orconectes wrighti Hardin County crayfish Center of range G2 S1 Presumed Stable
-0.5 0
0.5 1
1.5 2
2.5 3
3.5 Anthropogenic Barriers Human Response to Climate Change Dispersal Physiological Thermal Niche Physiological Hydrological Niche Rarity of Physical Habitat Dependence on Other Species for Dispersal AVERAGE SENSITIVITY SCORE Primary Sensitivity Factors for Selected Tennesssee Mussels
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 38 Table 9. Conservation status and CCVI score for selected Tennessee GCN crayfish Scientific Name Common Name Relative Range Global Rank State Rank CCVI Score Fallicambarus hortoni Hatchie burrowing crayfish Center of range G1 S1 Presumed Stable Orconectes alabamensis Stateline crayfish Center of range G5 S2 Presumed Stable Orconectes incomptus Tennessee cave crayfish Center of range G2G2 S1 Presumed Stable Figure 14. Primary CCVI sensitivity factors for selected Tennessee crayfish. The x-axis indicates the average CCVI score for relevant indirect exposure and sensitivity factors among all crayfish assessed (see Tables 13 and 14 in Appendix A for detailed descriptions). Negative numbers indicate factors that decrease vulnerability, positive scores reflect increased vulnerability.
Factors with a 0 average score are not included in the chart, although it is important to recognize that these are average scores -
in some cases, individual factors that contribute to vulnerability might be offset by factors that decrease vulnerability.
Accordingly, this chart should be seen as supplemental to Table 23 in Appendix C.
4.1.2.2.7 Plants The team chose 26 of the states 552 GCN plant species for the CCVI assessment. More than half of the plants assessed ranked as Extremely Vulnerable or Highly Vulnerable (see Table 10). All eight of the plant species that ranked as Extremely Vulnerable, including American harts-tongue (Asplenium scolopendrium var. americanum), Pynes ground-plum (Astragalus bibullatus), rock gnome lichen (Gymnoderma lineare), Roan Mountain bluet/Venus pride (Hedyotis purpurea var. montana), whorled sunflower (Helianthus verticillatus), Spring Creek bladderpod (Paysonia perforata), Ruths golden aster
-0.2
-0.1 0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 Anthropogenic Barriers Human Response to Climate Change Physiological Thermal Niche Historical Hydrological Niche Physiological Hydrological Niche Rarity of Physical Habitat AVERAGE SENSITIVITY SCORE Primary Sensitivity Factors for Selected Tennessee Crayfish White fringeless orchid (Platanthera integrilabia) - FWS
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 39 (Pityopsis ruthii), and Tennessee yellow-eyed grass (Xyris tennesseensis) are also ranked in Tennessee as critically imperiled (S1), and all but American harts-tongue and Roan Mountain bluet ranked as either very rare or imperiled globally (G3, G2, G1).
The primary sensitivity factors for vulnerability of selected plants is their dependence on a narrowly-defined precipitation/hydrologic conditions, limited dispersal abilities, and the presence of natural and anthropogenic barriers to dispersal (see Figure 15, below, and Table 24 in Appendix C). For instance, species such as American harts tongue fern and rock gnome lichen, which depend on high humidity, are vulnerable to drier conditions. Conversely, two species that generally rank as rare (G3 and S3), Eggerts sunflower (Helianthus eggertii) and ginseng (Panax quinquefolius) scored as Increase Likely from a climate change perspective, as they are not considered sensitive to most of the CCVI risk factors. Confidence in CCVI scores was low for Shorts bladderpod (Physaria globose), moderate for spreading avens (Geum radiatum), and very high for all other species assessed.
Table 10. Conservation status and CCVI score for selected Tennessee GCN plants Scientific Name Common Name Relative Range Global Rank State Rank CCVI Score Asplenium scolopendrium var. americanum (syn.
Phyllitis scolopendrium var. americana)
American hart's-tongue Center of range G4T3 S1 Extremely Vulnerable Astragalus bibullatus Pyne's ground-plum Entire range G1 S1 Extremely Vulnerable Hedyotis purpurea var.
montana (syn. Houstonia montana)
Roan Mountain bluet/
Venus' pride Center of range G5T2 S1 Extremely Vulnerable Gymnoderma lineare Rock gnome lichen East/west edge of range G3 S1 Extremely Vulnerable Pityopsis ruthii Ruth's golden aster Entire range G1 S1 Extremely Vulnerable Paysonia perforata (syn.
Lesquerella perforata)
Spring Creek bladderpod Entire range G1 S1 Extremely Vulnerable Xyris tennesseensis Tennessee yellow-eyed grass Northern edge of range G2 S1 Extremely Vulnerable Helianthus verticillatus Whorled sunflower Northern edge of range G1Q S1 Extremely Vulnerable Solidago spithamaea Blue Ridge goldenrod Northern edge of range G2 S1 Highly Vulnerable
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 40 Table 10. Conservation status and CCVI score for selected Tennessee GCN plants Scientific Name Common Name Relative Range Global Rank State Rank CCVI Score Boechera perstellata (syn.
Arabis perstellata)
Braun's rockcress Southern edge of range G2 S1 Highly Vulnerable Physaria globosa (syn.
Lesquerella globosa)
Short's bladderpod Southern edge of range G2 S2 Highly Vulnerable Geum radiatum Spreading avens/
Appalachian avens East/west edge of range G2 S1 Highly Vulnerable Spiraea virginiana Virginia spiraea/
Virginia meadowsweet East/west edge of range G2 S2 Highly Vulnerable Platanthera integrilabia White fringeless Orchid/monkey-face orchid Center of range G2G3 S2S3 Highly Vulnerable Conradina verticillata Cumberland rosemary Center of range G3 S3 Moderately Vulnerable Dalea foliosa Leafy prairie-clover Center of range G2G3 S2S3 Moderately Vulnerable Echinacea tennesseensis Tennessee purple coneflower Entire range G2 S2 Moderately Vulnerable Hottonia inflate American featherfoil Center of range G4 S2 Presumed Stable Minuartia cumberlandensis (syn.
Arenaria cumberlandensis)
Cumberland sandwort/
Cumberland stitchwort Center of range G2G3 S2 Presumed Stable Scutellaria montana Large-flowered skullcap Northern edge of range G4 S4 Presumed Stable Clematis morefieldii Morefield's leatherflower Northern edge of range G2 S2 Presumed Stable Buckleya distichophylla Pirate bush Southern edge of range G3 S2 Presumed Stable Apios priceana Price's potato bean Center of range G3 S3 Presumed Stable Isotria medeoloides Small whorled pogonia/little five leaves Southern edge of range G2 S1 Presumed Stable Helianthus eggertii Eggert's sunflower Center of range G3 S3 Increase Likely Panax quinquefolius Ginseng Center of range G3G4 S3S4 Increase Likely
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 41 Figure 15. Primary CCVI sensitivity factors for selected Tennessee plants. The x-axis indicates the average CCVI score for relevant indirect exposure and sensitivity factors among all plants assessed (see Tables 13 and 14 in Appendix A for detailed descriptions). Negative numbers indicate factors that decrease vulnerability, positive scores reflect increased vulnerability.
Factors with a 0 average score are not included in the chart, although it is important to recognize that these are average scores -
in some cases, individual factors that contribute to vulnerability might be offset by factors that decrease vulnerability.
Accordingly, this chart should be seen as supplemental to Table 24 in Appendix C.
4.1.2.3 Some Cautions When Interpreting CCVI Results As with all vulnerability assessment approaches, users should exercise caution when interpreting results.
For instance, with tools such as the CCVI that provide rankings among a number of target species or systems, it is tempting to prioritize conservation efforts toward the species or systems that rise to the top as being among the most vulnerable. Yet, the results are likely to be most useful if managers consider the full range of climate change vulnerability rankings and not just focus on those species likely to be adversely affected. Certainly, identifying the most-vulnerable species and the factors underlying that vulnerability will help managers set priorities and identify strategies that might more effectively reduce the multitude of stressors, including climate change, to those species of concern. In some cases, however, managers may choose to focus actions on those species likely to persist or perhaps even thrive under climate change (i.e., those ranked as Presumed Stable or Increase Likely). For example, if an important keystone species is considered extremely vulnerable and likely to be extirpated from a region under climate change, managers may choose to place greater emphasis on a non-vulnerable species that could play a similar role in the ecosystem.
Another factor that warrants attention is the spatial scale at which the relevant species are assessed. The CCVI is designed to work best at a relatively small scale, such as a national park, wildlife refuge, or state (Young et al. 2011). At larger (e.g., regional or national) scales, variations in climatic variables, topographic diversity, and other factors can make assessments of both the direction and magnitude of species responses more difficult. Of course, this does not mean that vulnerability assessments across a
-0.5 0
0.5 1
1.5 2
2.5 Natural Barriers Anthropogenic Barrier Human Response to Climate Change Dispersal Historical Thermal Niche Physiological Thermal Niche Historical Hydrological Niche Physiological Hydrological Niche Disturbance Rarity of Physical Habitat Pollinators Specialization Dependence on Other Species Interaction Measured Genetic Variation Past Genetic Bottleneck AVERAGE SENSITIVITY SCORE Primary Sensitivity Factors for Selected Tennessee Plants
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 42 broader landscape are unimportant or unnecessary. Rather, climate change requires managers to consider a broader-landscape context to account for likely shifts in species distributions, to sustain ecological processes, and promote cross-institutional collaboration.
It is also important to recognize that there may be considerable complexities associated with species vulnerability to climate change that are not captured by the CCVI. For example, as noted in Young et al.
(2014), climate change can indirectly threaten species through factors (such as changes in disease transmission patterns and shifts in the population dynamics of natural enemies or invasive species) that can be difficult to predict and are not explicitly included as elements of indirect exposure or sensitivity in the CCVI. For some species, climate-related factors such as seasonal timing of maximum stream flows or greater swings in temperature extremes are more important than average annual temperature or annual moisture, which are the data points used in typical CCVI assessments. Supplemental information from additional modeling, expert input, and other sources may be warranted to provide a more-thorough analysis of potential vulnerability (Butler et al. 2014).
Finally, as noted previously, climate change does not occur in a vacuum but rather acts synergistically with many other factors that are of concern for conservation of Tennessees GCN species. In some cases, climate change may not pose a major risk for a species, but that does not necessarily mean that the species is not otherwise imperiled. For example, a species assessed as Presumed Stable under the CCVI may still be impacted by other stressors unrelated to climate change, such as overharvest. In other cases, climate change might benefit a species, reducing the need to address some other threats. An increase in wildfire, for example, may favor species that rely on early-successional habitat. Ultimately, managers will need to consider the broad context of conditions in which species and associated habitats exist, both now and in the future, in order to develop effective conservation strategies.
These cautions notwithstanding, the CCVI provides useful tool for managers to begin to look at their conservation targets through a climate change lens - a necessary step for effective climate change adaptation (Stein et al. 2014).
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 43 4.2 VULNERABILITY OF TENNESSEE HABITATS Some of the most-significant impacts of climate change on Tennessees fish and wildlife species will be associated with changes to their terrestrial and aquatic habitats. This section provides a brief summary of habitat vulnerabilities based on a review of the scientific literature. More in-depth assessments of regional scale habitat impacts are provided by the following sources: EPRI (2009), TWRA (2009), and McNulty et al. (2013).
4.2.1 Terrestrial Habitats 4.2.1.1 Shifts in Vegetation Climate change is projected to contribute to significant changes in the composition of associated plant species in both forest and grassland systems across Tennessee due to direct changes in suitable climate conditions (e.g., increasing temperatures and changes in precipitation patterns), indirect changes (e.g.,
altered disturbances such as wildfire and insect outbreaks), and an increase in the atmospheric concentration of carbon dioxide (CO2). Some impacts will occur in the near term, while others are likely to take decades. For example, although direct impacts of higher temperatures and changes in moisture on terrestrial habitats may be gradual, more-extreme disturbances such as wildfires could lead to dramatic changes in habitat within a relatively short period (Dale et al. 2000). In addition, changing CO2 levels put certain types of plants at either a relative growth advantage or disadvantage, depending on the type of photosynthetic pathway they have (Poorter and Navas 2003, McNulty et al. 2013). This will likely have an effect on both species competition and regeneration.
It is important to recognize that the projected changes in vegetation types differ depending on the particular climate and vegetation change models, greenhouse gas emissions scenarios, and the data and assumptions used for the respective analyses. Several studies project a decline in floodplain-associated species such as cottonwoods and ash and an increase in oak-hickory forest in the Mississippi Alluvial Plain by the end of this century (Prasad et al. 2007, EPRI 2009). Oak-hickory forest is expected to persist in the Interior Low Plateau and Cumberland Plateau regions, although Iverson and Prasad (2002) suggest that there is likely to be encroachment from loblolly and shortleaf pines under some scenarios. Other studies (e.g., Iverson and Prasad 2001, Iverson et al. 2008, TWRA 2009) project a decline in loblolly/shortleaf pine forests and maple/beech/birch forests in Tennessee by 2100. Trees and forest systems adapted to more-northern latitudes, including eastern hemlock, spruce-fir forest, and northern hardwood forest, could be eliminated entirely from higher-elevation areas of the Southern Blue Ridge by the end of the century (Prasad et al. 2007, EPRI 2009). Research also indicates the potential for significant savannafication across the Southeast, in which forests are converted into more-open woodlands due to a combination of hotter and drier conditions (Hansen et al. 2001, McNulty et al. 2013).
Prairie vegetation in Tennessee - TWRA
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 44 Bachelet et al. (2003) project that winter deciduous forest could be replaced by coniferous forest or grassland in the western part of Tennessee by 2030, with expansion of savanna throughout the state by 2095.
4.2.1.2 Altered Disturbances Forest and grassland systems in Tennessee are naturally exposed and adapted to a certain degree of disturbances such as wildfires, droughts, and insect and disease outbreaks. Changes in the frequency and severity of many these disturbances, however, are expected to contribute to shifts in habitat quality and composition (Dale et al. 2001). For example, higher air temperatures are projected to increase regional drying through increased forest water use via evapotranspiration, regardless of changes in precipitation.
This drying is likely to increase wildfire risk across southeastern forests (McNulty et al. 2013). Studies indicate that the Souths spring and fall wildfire seasons will be extended (Stanturf and Goodrick 2013) and that the area burned by wildfire will increase (Flannigan et al. 2000).
The implications of changes in wildfires for the region are likely to be complex. In principle, an increase in the frequency of wildfires could enhance some habitats, such as calcareous glades and barrens, which have historically relied on fire and grazing by megafauna but have declined in the region due in part to historical fire-suppression practices (NWF and NatureServe 2014). On the other hand, in areas with currently-high fuel loads, such as the southern Appalachian and Blue Ridge forests, drier conditions could lead to high-severity, stand-replacing fires and the potential conversion from one habitat type to another (Flannigan et al. 2000, Lenihan et al. 2008).
As conditions become more favorable for wildfires in the state, managers will increasingly need to weigh the potential ecological benefits of allowing some fires to burn, where and when prescribed burns will be appropriate to manage fuels or restore ecosystems, and the need to suppress fires for purposes such as improved air quality and protection of property (Stanturf and Goodrick, 2013, Mitchell et al. 2014).
Climate change is also expected to increase the extent and frequency in outbreaks of both native and non-native forest insects and disease pathogens across the southeastern United States (McNulty et al. 2013).
Not only does climate change affect the viability and spread of insects and pathogens directly, for instance by allowing greater winter survival, but it also can increase the susceptibility of host trees to outbreaks due to drought stress and other factors (Dale et al. 2001). Several insect species, including southern pine beetle (Dendroctonus frontalis) and hemlock wooly adelgid (Adelges tsugae), have already Prescribed burn, Great Smoky Mountains National Park - NPS
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 45 caused considerable forest damage in parts of Tennessee (Duerr and Mistretta 2013). Higher average temperatures are expected to enhance winter survival and exacerbate outbreaks of both species, as well as contribute to their expansion northward (Gan 2004, Paradis et al. 2008). Indeed, studies suggest that climate change could increase the risk of southern pine beetle infestations across the Southeast by 2.5-5 times and could result in 4-7.5 times the current annual mortality of pines (Gan 2004). Persistence of the hemlock wooly adelgid is projected to lead to a complete loss of eastern hemlock from the Cumberland Plateau and Mountains region by the end of the century (Paradis et al. 2008, Evans and Gregoire 2007, Dale et al. 2009).
4.2.1.3 Altered Ecological Processes The impacts of climate change on forest structure and functions could have a considerable impact on important ecological processes, such as regulation of water quality and quality, by altering key hydrologic fluxes (including precipitation and evapotranspiration) and biochemical processes. For example, under most climate scenarios analyzed, increasing temperatures and decreasing precipitation are projected to result in a greater uptake of soil water by forests and lead to reductions in streamflow, with associated impacts on aquatic fish and wildlife (Sun et al. 2011, McNulty et al. 2013). These changes are likely to be exacerbated by other stressors, such as ground-level ozone pollution, the concentration of which is expected to increase as temperatures rise given the relationship between heat and the chemical reactions between oxides of nitrogen and volatile organic compounds (Jacob and Winner 2009). A study modeling the effects of ozone exposure and climate change on tree transpiration in Tennessee suggests that ozone at near ambient concentrations can reduce stomatal control of leaf transpiration and increase water use (Sun et al. 2012). Increases in evapotranspiration and associated streamflow reductions in response to ambient ozone exposures are expected to episodically increase the frequency and severity of drought and affect flow-dependent aquatic biota in forested watersheds.
4.2.1.4 Implications for Wildlife The impacts of climate change on terrestrial habitats will have positive effects on some species and negative effects on others. For example, if climate change contributes to a widespread decline in the less-adapted trees that currently comprise the overstory, there will be an increase in canopy gaps of varying sizes (TWRA 2009). This would likely result in more understory vegetation and more early-successional wildlife habitat until better-adapted tree species become established. When overstory declines, however, invasive exotic vegetation, especially plants that benefit from higher temperatures and CO2 levels, may gain a foothold (Simberloff 2000). The predicted modest expansion of oak-hickory forest type in some areas could benefit species that rely on the cover and structure provided by forest interiors as well as those Drought-stressed vegetation along the Nolichucky River in 2007 - NOAA
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 46 that depend on hard mast for food. Where tree mortality is greatest, such as is projected for the elm-ash-cottonwood systems, the disappearance of areas of later-successional forest would adversely affect interior forest wildlife species.
Given the complexities and uncertainties in climate projections and associated impacts, the general challenge for managers is to consider how to define desired conservation outcomes and maintain Tennessees high biodiversity values in the context of overall terrestrial habitat changes (Joyce et al.
2008). The states upland forest systems, for instance, support a great diversity of wildlife due in part to the variety of different habitats and niches found within a structurally diverse forest system (TWRA 2014). Managing for a diversity of habitat types, even if the composition of associated vegetation changes, may still support desired conditions for valued fish and wildlife.
4.2.2 Aquatic Habitats Tennessees rivers, streams, lakes, and wetlands support a tremendous diversity of fish and wildlife species. Indeed, the states rivers and streams are home to more species of fish, mussels, and crayfish than any other state in the country (TWRA 2014). Climate change is expected to have a considerable impact on aquatic habitats in Tennessee and across the Southeast (Anderson et al. 2013, McNulty et al. 2013).
Higher temperatures and changes in precipitation patterns, in particular, will affect water temperatures and water quality and alter hydrological conditions to which many species of fish and wildlife have adapted.
4.2.2.1 Higher Water Temperatures and Altered Water Quality Higher average air temperatures are likely to have a direct effect on water temperatures, although the localized impacts will depend on factors such as groundwater inflow and riparian cover (Marion et al.
2014). In addition, human-related factors that affect water temperature may include runoff from impervious surfaces and releases of water from reservoirs. In some areas, higher water temperatures could put organisms closer to the threshold for their thermal tolerance and exacerbate low dissolved oxygen conditions (Hopkinson et al. 2013). In general, higher water temperatures are expected to have an adverse impact on coldwater fish habitat throughout the Appalachians (Sun et al. 2013), although the impacts will vary geographically. Streams and rivers generally transition to higher average temperatures as water travels downstream. For example, while the headwaters of the Tellico River have cold water that support trout populations, downstream it warms to become warmwater habitat that supports Brook trout (Salvelinus fontinalis) thrive in water temperatures of 65°F or lower - FWS
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 47 smallmouth bass (Micropterus dolomieu) (TWRA 2009). Between these reaches, there is a transition zone that is not well suited for either species due to temperature (TWRA 2009).
In a warming scenario, warmwater species are likely to migrate upstream as water temperatures in the transition zone become more favorable. Ultimately, there is likely to be a loss of coldwater habitat in the upper reaches. The ability for species to migrate upstream will also be affected by the existence of natural and/or anthropogenic barriers such as dams and culverts. Much of the riverine habitat in the Tennessee and Cumberland Rivers was converted to reservoirs in the early 20th century, and many dams and culverts continue to limit movement of species and reduce water quality (TWRA 2014).
Given that reservoirs also support some of Tennessees aquatic species, impacts of climate change on those systems are also likely to be a factor in their management. In large tributary reservoirs, for example, an increase in water temperatures will negatively affect cool-to coldwater fish habitat, while benefiting warmwater species (TWRA 2009). Some species may be able to retreat to deeper cool water associated with stratification, although excess nutrients may lead to hypoxic or anoxic conditions in those zones.
Warmer water may also make rivers and reservoirs more suitable to non-native species that already inhabit waters to the south (TWRA 2009). For example, warmer waters are projected to facilitate the spread of invasive zooplankton such as Daphnia lumholtzi in lakes and reservoirs, altering the aquatic food web (Lennon et al. 2001, Fey and Cottingham 2011).
4.2.2.2 Changes in Hydrology Coupled with other stressors such as water withdrawals and dams, climate change is expected to have a significant impact on the hydrology of Tennessees lakes, rivers, and streams. Although droughts are historically common in Tennessee and are an important part of interannual habitat variability in rivers, severe droughts could adversely affect already-stressed species by reducing invertebrate production, disrupting fish migrations, and exposing aquatic species to higher water temperatures and lower dissolved oxygen. (TWRA 2009). More-frequent droughts are likely to contribute to more-frequent stream drying events, even in those systems that are considered perennial (Hopkinson et al. 2013). This, in turn, may increase the frequency of local species extirpations. Alternately, changes in the intensity of rainfall events are expected to contribute to higher runoff, erosion, and excessive sedimentation in rivers and streams, particularly in areas where riparian vegetation is limited (Treasure et al. 2008, Sun et al. 2013). In addition, high flows can scour nests and reduce habitat for species such as brook trout (TWRA 2009).
Changes in the timing and magnitude of streamflows affect important and habitat for a number of aquatic species (TWRA 2009). For example, recent research in the Tennessee River basin has found that even small deviations in streamflow can significantly reduce the diversity of fish species within that system (Knight et al. 2014). Climate change is likely to exacerbate other anthropogenic factors, such as water withdrawals, that influence streamflows in Tennessee. The state will need to address significant tradeoffs among competing water uses as climate change contributes to greater variability and extremes in water resources and associated hydrological conditions across the region. If drought conditions become more persistent, as some studies suggest, there is likely to be increased demand for water for municipal, agricultural, and industrial consumption. These uses may increasingly be at odds with maintaining instream flows for navigation, recreation, habitat, and other purposes (EPRI 2009).
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 48 4.2.2.3 Wetland Habitat Loss More than 90% of Tennessees historic wetlands have been lost, largely due to draining for agriculture or development (TWRA 2014). This includes 80% of the bottomland hardwood wetland forests in the Mississippi Alluvial Plain in Tennessee and other southern states. Freshwater marshes and swamps are highly vulnerable to warming, changes in precipitation and severity of storms, and the frequency and severity of drought (Hopkinson et al. 2013). The combined effects of higher temperatures and changes in precipitation are expected to increase evapotranspiration and reduce stream base flows, which could lead to drying of isolated wetland systems that are important habitat for a variety of plants and animals.
Vernal pools are especially vulnerable to climate change since their hydrology is strongly dependent on precipitation and evaporation (Keely and Zedler 1998).
Climate change may affect the size of pools as well as the timing under which they fill and dry up, all of which are likely to affect species that rely on these systems for part or all of their life cycle (Graham 2013). Furthermore, because wetlands can play an important role in absorbing floodwaters, the loss of these habitats in some areas may also serve to exacerbate flooding events associated with an increase in the intensity of heavy downpours.
4.2.2.4 Implications for Wildlife As with terrestrial species, the impacts of climate change on Tennessees aquatic fish and wildlife will be considered favorable for some species but adverse for others. For example, as noted above, some cool-and warmwater fish could see an increase in suitable stream and reservoir habitat across parts of the state as average temperatures increase. Conversely, coldwater species are likely to face a loss of habitat.
With many of Tennessees highly-diverse aquatic species already considered at-risk for a variety of reasons, the additional threat from climate change is likely to exacerbate conservation concerns (TWRA 2009). Indeed, it is the combination of climate change and other stressors such as polluted runoff and barriers to stream connectivity that will have the greatest impact on aquatic habitats and the species that depend on them (Sun et al. 2013). An integrated approach to managing aquatic species and habitats that takes into account multiple stressors, including climate change, will be important to help the state meet is short-and long-term wildlife conservation goals.
Gum Swamp at Cades Cove when dry - USGS
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 49 4.3 KEY VULNERABILITIES Drawing from the vulnerabilities for species and habitats highlighted in this section, the Tennessee team undertook a process to winnow down the broad array of concerns to a set of key vulnerabilities (see Table 11). Essentially, the key vulnerabilities are those vulnerabilities considered to be the most critical for managers to address given the particular risk they pose to achieving Tennessees conservation goals and objectives (Stein et al. 2014). In the face of many possible targets for adaptation actions, identification of key vulnerabilities provides a structured means for setting priorities in the development, evaluation, and selection of adaptation strategies and measures.
Table 11. Key vulnerabilities of Tennessee species and habitats Climate Change Drivers Potential Impacts Key Vulnerabilities Changes in precipitation timing and duration Increased frequency, duration, and intensity of drought Changes to seasonal timing, frequency, and magnitude of moderate and extreme flood events Changes to habitat availability for different life history stages Interactions with water quality conditions Instream flow management response issues Low flow/extreme low flow and base flow alteration could result in reduced habitat quality and connectivity for aquatic species.
More-extreme flood events could lead to habitat destabilization (especially in headwater/smaller order streams), affect spawning cues for some species, and interrupt the availability of feeding and nursery grounds.
Increases in stormwater runoff are likely to exacerbate input of excess nutrients and toxicity loading and contribute to altered pH and dissolved oxygen levels.
Extreme droughts could alter habitat availability, including breeding habitat and food sources for birds, spawning habitat for mussels and fish, and vernal pools for amphibians.
Increasing temperatures Contributions to terrestrial habitat shifts Relationship to pest and pathogen spread Changes to freshwater and cave habitat suitability Interactions with water quality conditions Contributions to phenological mismatch Thermal habitat suitability is likely to be reduced for a number of aquatic species, especially brook trout, hellbender, and some mussel species.
Increased evaporation is expected to cause drying of vernal pool habitats.
Higher temperatures in caves could harm certain cave fish and bat hibernacula.
Significant shifts in forest habitat types are projected, particularly at higher elevations and in the western portion of the state.
Negative impacts are expected among high-elevation habitat-dependent species such as southern rock vole and Carolina northern flying squirrel.
Spread of pests and pathogens are likely to affect plant and animal species both directly and indirectly.
Phenological mismatch could lead to disruptions in species interactions and mutualisms (e.g., timing of insect emergence and other food sources for birds, fish, and other species).
Altered disturbances (i.e.,
fire, wind damage, ice storms)
Contributions to terrestrial habitat shifts Relationship to spread of invasive species Damage to habitat Increasingly extreme events could have adverse effects on habitat quantity and quality, especially in forest communities.
Altered fire regimes could pose significant challenges for fire management practices.
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 50 4.4 SPATIAL VULNERABILITY ANALYSIS FOR TENNESSEE 4.4.1 Overview of Spatial Vulnerability Assessments Spatial, or geographic, analyses can be useful tools to assess the vulnerability of relevant conservation targets to climate change and associated impacts. Such information can help managers identify priority areas for conservation and can help inform specific management actions based on the underlying factors that contribute to vulnerability (Steel et al. 2011).
There are many ways of assessing vulnerability to climate change across the landscape. Some of the more-common approaches use models to identify potential spatial distribution of species or habitat types based on specific biophysical attributes, ecological processes, and/or other factors that determine where suitable climatic conditions for those species or systems may exist in the future. These models range in complexity, from climate envelope models to dynamic ecological models (Hayhoe et al. 2011). Another approach is to use a spatial vulnerability index, a tool that is designed to calculate and display various indicators of vulnerability across a geographical area (Joyce et al. 2008, Anderson et al. 2014, USAID 2014). Often, a combination of approaches will be appropriate.
One way to visualize potential vulnerability of species and habitats of conservation concern is to develop geographic information system (GIS) overlay maps, or blueprints. A relatively straight-forward approach is to identify the exposure of existing priority conservation areas to various elements of climate change and associated impacts (e.g., exposure to increasing temperatures, changes in vegetation, or inundation from rising sea levels). For example, Kershner and Mielbrecht (2012) have developed a Climate-informed Conservation Blueprint for the Greater Puget Sound ecoregion in Washington State.
Their approach combines GIS maps showing areas of predicted future vegetation change (based on MC1 dynamic vegetation model from Bachelet et al. [2001]), areas of biodiversity significance (based on TNCs ecoregional assessments for Washington), core landscape integrity areas (based on the Washington Wildlife Habitat Connectivity Working Group [WHCWG] Connected Landscapes Project
[Washington WHCWG 2010]), and areas with concentrations of focal species (also based on the Washington WHCWG Connected Landscapes Project). With this information, the team was able to identify areas of land that they consider as providing the best opportunities for species and habitats to persist under changing climate conditions, and areas where habitat connectivity could be restored or maintained to facilitate species movements.
As with the CCVI, some caution is warranted when interpreting these types of overlay maps. For example, there often are inconsistencies in the spatial resolution used in the various maps being compared, so the degree to which focal areas across different maps overlap are likely to be inexact. In addition, uncertainties can exist in the underlying data, ranging from the various levels of accuracy and resolution of the maps to the complexity, assumptions, and uncertainties associated with climate and ecological response models. As such, these maps may be most appropriate for planning at a relatively-coarse scale (Kershner and Mielbrecht 2012).
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 51 The following is a preliminary analysis for Tennessee that draws from the approaches used by Joyce et al.
(2008), Kershner and Mielbrecht (2012), and Anderson et al. (2014), with a focus on terrestrial habitats and associated species. The assessment is based on several existing datasets and maps, including:
Terrestrial Habitat Priority areas in Tennessee (TWRA 2015);
Areas in Tennessee predicted to experience vegetation change using the MC2 dynamic vegetation model (Bachelet et al. 2014);
Areas rated using the Terrestrial Climate Stress Index (USDA Forest Service in press, Joyce and Flather personal communication); and Areas rated using the Resilient Sites for Terrestrial Conservation approach (Anderson et al.
2014).
4.4.2 Foundational Maps for Tennessee This section describes the spatial analyses created for understanding different attributes of Tennessees landscape. These separate analyses were then overlaid in a blueprint fashion to ascertain landscape-level patterns that provide important context for decision-making on desired conservation outcomes and potential climate adaptation strategies.
4.4.2.1 Terrestrial Habitat Priority Areas TWRA and TNC, with input from a variety of technical experts, developed a methodology for mapping priority habitat areas for all GCN species in the state (TWRA 2015). For terrestrial species, the methodology included the following basic steps:
- 1) Assignment of expert-derived habitat preference ratings for each GCN species to NatureServe ecological systems, as mapped by the 2008 Southeast Gap Analysis Project (http://www.basic.ncsu.edu/segap (accessed September 8, 2015);
- 2) Calculation of a priority score for each GCN species using data on how recently the species were recorded in each location combined with relevant rarity designations (e.g., G-and S-Rank and federal and state legal listing status); and
- 3) Modeling potential habitat occupancy based on species observation records and NatureServe information on relative dispersal abilities to calculate that species footprint.
To develop the habitat priority maps, the GCN prioritization scores were combined with the species footprint and their habitat preference scores. For more information on this methodology, see TWRA 2015 and Palmer and Wisby 2015.
Figure 16 shows the Terrestrial Habitat Priority areas for Tennessee. The darker-green colors indicate higher habitat priority areas, while the yellow-green colors indicate the lower habitat priorities. Areas shaded dark gray denote developed/urbanized land. Identification of these habitat priorities was a key step in the selection of locations defined as Conservation Opportunity Areas (COAs), which has become a valuable step for many states as they revise and implement their SWAPs (AFWA 2012). Essentially, COAs are areas that represent the greatest potential for conservation of GCN species, as determined by the state. They are intended to help guide and improve the outcomes of species and habitat conservation efforts and facilitate outreach and coordination with relevant partners across the state. The concept for identification of COAs in Tennessee has been to find important intersections between habitat priority areas, the types and severity of stressors affecting those habitats, and key opportunities to act (TWRA
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 52 2015). As Tennessee continues to integrate climate change into its conservation efforts, the information presented in the report should serve as a useful tool to inform the COA management process.
4.4.2.2 Vegetation Change Analysis using the MC2 Dynamic Vegetation Model As discussed previously, climate change is expected to contribute to changes in the composition of major vegetation types across the state. One model used to assess such changes is MC2 dynamic global vegetation model, which simulates potential changes in the distribution of dominant vegetation types (i.e.,
deciduous-evergreen trees and C3-C4 grasses) across biogeographical regions based on projected changes Figure 16. Terrestrial Habitat Priorities for western (upper map) and eastern (lower map) Tennessee (TWRA 2015). The areas shaded in the darkest green scored as Very High habitat priorities, while the areas shaded in yellow-green scored as Very Low priorities. Areas in dark gray denote developed/urbanized land.
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 53 in climate and associated variables (Bachelet et al. 2001, Bachelet et al. 2014). Specifically, the model identifies areas in which certain vegetation types are likely to reach ecological thresholds that lead to shifts from one functional vegetation type (e.g., Temperate Deciduous Broadleaf Forest) to another (e.g.,
Temperate Warm Mixed Forest) by simulating biochemical processes associated with carbon and nutrient dynamics including plant production, solid organic matter decomposition, and water and nutrient cycling, and the occurrence, behavior, and impacts of severe fire. The model can be run with or without a fire suppression algorithm to identify potential changes under alternative fire management scenarios.
Researchers at the U.S. Forest Service Rocky Mountain Research Station have applied MC2 across the United States (Joyce and Flather personal communication, USDA Forest Service in press). For this assessment, the authors have parsed out data for the Tennessee (Joyce and Flather personal communication). MC2 was run using climate projections from three global climate models (UKMO HadCM3, CSIRO-MK3.0, and MIROC) from the Intergovernmental Panel on Climate Change Fourth Assessment Report (IPCC 2007) under three Special Report on Emissions Scenarios (SRES)1: A1B, A2, and B1. The specific projections for vegetation changes (e.g., areas where vegetation shifts from Temperate Deciduous Broadleaf Forest to Temperate Warm Mixed Forest or Temperate Evergreen Needleleaf Forest) vary across models and emissions scenarios due to differences in model projections for temperature and precipitation changes for the region.
Figure 17 shows results of the vegetation change projections for the period 2050-2099, compared to the baseline period 1950-1999, with an assumption of no fire suppression efforts (USDA Forest Service in press, Joyce and Flather personal communication). The scale here is an equal area hexagon grid with each cell approximating an area of approximately 69 km2. The map highlights the number of times the vegetation changes from the historical type across nine projections using the three climate models and three emissions scenarios. The warmer colors (reds) show areas where vegetation changes under most or all of the models and scenarios run (i.e., areas that more likely to undergo a shift in dominant vegetation type under climate change), while the cooler colors indicate areas where little or no change in vegetation occurs. From this, one may infer that vegetation types in the northeastern portion of Tennessee are generally less vulnerable to change under future climate conditions than those in the southern and southwestern portions of the state.
1 The suite of climate change scenarios on which many projections are based come from a set of scenarios developed by the IPCC SRES (Nakicenovic and Swart 2000). The scenarios span a range of possibilities for future greenhouse gas emissions based on estimates for things like population growth, economic activity, technological advances, and policy measures (with A1T, B1, and B2 suggesting a lower-range of emissions and A1B, A2, and A1FI suggesting higher emissions). Importantly, given current and near term emissions projections, the lowest emissions scenarios are looking to be less-plausible. In fact, recent emissions trajectories have been higher than those in the IPCCs highest emissions scenario, A1FI. Strong international emissions reductions initiatives would allow for more moderate trajectories such as the IPCCs A2 and A1B scenarios.
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 54 When interpreting the model results for management decisions, it is important to recognize some limitations. One is that the vegetation change analysis does not incorporate land use as a factor in determining availiability of habitat. In many areas, including Tennessee, land use for agriculture and development are likely to have a significant impact on the ability for both plants and animals to disperse across the landscape (USDA Forest Service 2012). Furthermore, the MC2 model does not simulate changes in wetland vegetation types, which are important habitat for a range of species and may be especially vulnerable under warmer, drier conditions. Supplementing analyses such as this with additional information, where available, will enhance relevant decisions-making processes.
4.4.2.3 The Terrestrial Climate Stress Index (TCSI)
The Terrestrial Climate Stress Index (TCSI) identifies areas of stress across target geographical areas based on a sum of separate terms that reflect projected changes in mean annual temperature and precipitation (the climate regime), associated changes in biomass production (an indicator of habitat quality), and climate-induced distribution shifts in broad vegetation types (an indicator of habitat area) across target geographical areas (Joyce et al. 2008, USDA Forest Service 2012, USDA Forest Service in press). The projected changes in biomass and vegetation were obtained from an application of the dynamic global vegetation model MC2, described above.
The TCSI is an indication of the degree of change in these key factors between recent history and the projected future (Joyce et al. 2008, USDA Forest Service 2012, USDA Forest Service in press). Mean scores are estimated for each grid cell in the target area across a set of various emissions scenarios, Vegetation Type Change from Historical (1950-1999) to Future (2050-2099) Conditions in Tennessee using the MC2 Dynamic Vegetation Model with No Fire Suppression Figure 17. Results of the analysis of vegetation type change in Tennessee using the MC2 model (Joyce and Flather personal communication). The colors indicate the number of times vegetation changed from the historical (1950-1999) type to the future (by 2050-2099) across nine projections (three GCMs and three emission scenarios: A2, A1B, and B1), with a model assumption of no suppression of fire. The dark blue (0) = future vegetation types remained unchanged from historical under all scenarios; brownish-red (9) = future vegetation always changed from historical.
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 55 climate models, and assumptions about the effects of CO2 on plant growth. The mean TCSI score represents the average result across the range of potential alternative futures.
In its applications to date, the index scores have been ranked using a percentile approach to indicate areas with the greatest change under future climate change (2050-2099) when compared to the baseline period (1950-1999). High stress is defined as the top 20 percent highest scoring grids in the TCSI over the study area, while low stress areas are the 20 percent grids with lowest scores. The areas are then mapped across the relevant study region according to the relative scores.
For this analysis (hereafter called the modified TCSI), the mapping methodology was revised from the percentile approach to a normalized approach that takes the average of: 1) percentile rank, and 2) normalized TCSI value. The resulting index is on a 0-100 scale, as both input scores and percentages. The TCSI scores were then categorized using ArcGISs Natural Breaks (i.e., Jenks Optimization) classification. This is the same approach used for the habitat priority stratification (highlighted above) and is closer to the approach used for the Resilient Sites analysis (described below), making the associated maps more comparable. Figure 18 shows the modified TCSI results for Tennessee under the A1B emissions scenario. Areas in green reflect the low stress scores, and areas in red high scores.
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 56 4.4.2.4 Resilient Sites for Terrestrial Conservation The Resilient Sites for Terrestrial Conservation was developed to facilitate the identification of terrestrial areas that are expected to continue to support high levels of biodiversity under changing climate conditions given a variety of ecologically-relevant physical landscape features (Anderson et al. 2014).
This approach is drawn from the strong correlation between species diversity and geographical diversity in the eastern United States (Anderson and Ferree 2010). In topographically-complex landscapes, for Figure 18. Results of the modified Terrestrial Climate Stress Index (TCSI) application for western (upper map) and eastern (lower map) Tennessee. Areas in green reflect low stress scores, and areas in red high stress scores (adapted from Joyce and Flather personal communication).
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 57 example, species may be able to take advantage of micro-climates that either remain or become suitable as ambient climate conditions change (Weiss et al. 1988). Species may also be able to physically move to adjust to climatic changes if the landscape features of an area are permeable and connected. Accordingly, ratings of resilience are based on factors associated with physical complexity of the area (i.e., landform variety, elevation range, and wetland density) and its permeability (local connectedness and regional flow patterns, based on existence and extent of both anthropogenic and natural barriers).
Under this framework, resilience to climate change and its converse, vulnerability, are relative concepts, not absolute thresholds. Relative vulnerability scores are stratified across the various geophysical settings within natural ecoregions. In its application of the Resilient Sites framework for the Southeast Region (Anderson et al. 2014), TNC used the ecoregions identified in Figure 19. This ecoregional stratification process is important because natural landscape features vary greatly ecoregion by ecoregion; therefore, the potential resilience of an area should be compared relative to similar areas within the same ecoregion.
Sites are considered more or less resilient as represented by standard deviations from the average overall resilience score for their ecoregion. More-resilient sites identified by this analysis are hypothesized to offer greater adaptive capacity by providing features such as more-diverse microclimates and greater overall habitat. Less-resilient sites are already highly fragmented or have a lower potential for providing a diversity of microhabitats over time.
Figure 19. Southeastern ecoregions (https://www.conservationgateway.org/ConservationByGeography/NorthAmerica/UnitedStates/edc/PublishingImages/ED_rotat or_Ecoregions.jpg, accessed June 18, 2015).
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 58 Figure 20 shows estimated resilience of sites for Tennessee stratified by ecoregion. For this analysis, the geophysical settings were assessed at 30-meter resolution and interpreted as 100-acre hexagons. Areas whose score is far below the average (shown in dark brown) are considered more vulnerable relative to the average for the ecoregion, and those far above average (in dark green) are more resilient relative to other sites containing that geophysical setting within the same ecoregion.
Figure 20. Resilient Sites for Terrestrial Conservation scores for western (upper map) and eastern (lower map) Tennessee, stratified by geophysical setting and ecoregion. Areas whose score is far below the average (shown in dark brown) are considered most vulnerable, and those far above average (in dark green) are most resilient (adapted from Anderson et al.
2014).
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 59 4.4.3 Overlay Maps for Tennessee The maps that follow are intended to provide landscape-scale information for managers as they define conservation outcomes and identify climate adaptation options within the SWAP and other resource management planning efforts. The maps identify where projected changes in major vegetation types coincide with areas currently providing high-priority terrestrial habitat for GCN species, as well as helping discern which regions provide more or less landscape resilience and potential adaptive capacity.
4.4.3.1 Overlay of Terrestrial Habitat Priority Areas and the Modified Terrestrial Climate Stress Index (TCSI)
Figure 21 presents an overlay of the state-level modified TCSI results and Tennessees Terrestrial Habitat Priority areas. Here, high priority habitats showing high TCSI risk are shown in darker red; medium priority habitats at moderate TCSI risk are darker yellow, and so forth (as indicated in the legend). Darker green areas are those considered to be high habitat priority but have lower TCSI risk.
In general, Southern Floodplain Hardwood Forest areas along the Mississippi River Alluvial Plain and parts of the Upper Gulf Coastal Plain, and areas of Southern Central Mixed Deciduous Evergreen Broadleaf Forest, Central Oak Hardwood and Pine Forest, and glade and barrens habitats in the Interior Low Plateau have the greatest concentration of high priority habitat areas overlapping with those scoring as high stress under TCSI. The forested areas of the Cumberland and Southern Ridge and Valley and Southern Blue Ridge ecoregions encompass most of the high habitat priority areas with lower TCSI scores.
This information may help inform a variety of different management choices. For example, those areas identified as high terrestrial habitat priorities projected to experience relatively low climate-induced stress (dark green on the map) could point to possible refugia, where terrestrial vegetation and other conditions may continue to provide favorable habitat for associated GCN species over time. In habitat priority areas that face higher relative climate stress, managers may need to tailor conservation actions to reduce factors associated with that climate stress, such as reducing vulnerability to fire or other disturbances that may accelerate changes in associated vegetation types, or placing greater emphasis on supporting desired ecological functions rather than specific species assemblages.
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 60 4.4.3.2 Overlay of Terrestrial Habitat Priority Areas and Resilient Sites for Terrestrial Conservation Figure 22 shows an overlay of the Resilient Sites for Terrestrial Conservation and the Terrestrial Habitat Priority areas for Tennessee. Here, areas highlighted in darker green are high habitat priorities that coincide with relatively-high (above-average) landscape resilience scores. Areas in yellow to light orange are medium-to high-priority habitats with average resilience scores. Areas in darker red indicate places of Figure 21. Overlay of the modified TCSI and Terrestrial Habitat Priorities for western (upper map) and eastern (lower map)
Tennessee. High priority habitats also ranked as high TCSI risk are shown in darker red; high priority habitats ranked as low TCSI risk are in darker green.
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 61 high habitat priority currently, but that have below-average landscape resilience and therefore may be more vulnerable to change over time.
As with the modified TCSI and Terrestrial Habitat Priorities comparison, these maps can provide insights as to how climate change might influence conservation priorities and actions. There are a number of areas that are identified as both high habitat priorities and resilient sites (the darkest green), which indicates that these sites may continue to be important areas to maintain for biodiversity moving forward. Implementing conservation efforts across a diverse portfolio of these sites is likely to increase the probability of their persistence over time (Anderson et al. 2014).
However, there also are a number of areas that have been identified as high habitat priorities but appear more vulnerable. In these cases, managers may need to investigate some of the underlying reasons for that vulnerability, such as low connectedness, for which specific conservation actions such as elimination of anthropogenic barriers or expansion of open space might be useful. Similarly, there are areas currently identified as very low habitat priorities but that score far above average on the resilience scale (light green). Ultimately, some of these areas may warrant reconsideration as a focus of conservation efforts depending on a variety of factors including (but not limited to) local site conservation objectives or regional connectivity goals (Anderson et al. 2014).
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 62 4.4.3.3 Overlay of the Modified Terrestrial Climate Stress Index and Resilient Sites for Terrestrial Conservation Figure 23 compares areas where relative changes in vegetation types and biomass production are expected under future climate conditions, as indicated by the modified TCSI, with their resilience scores calculated by the Resilient Sites for Terrestrial Conservation approach. Areas with low landscape resilience scores and high TCSI ranking are shown in dark red. The dark green areas indicate high landscape resilience and low TCSI scores.
Figure 22. Overlay of Resilient Sites for Terrestrial Conservation with Terrestrial Habitat Priority areas for western (upper map) and eastern (lower map) Tennessee. The darkest green areas are those identified as both high habitat priorities and resilient sites, while areas shaded in pink are low resilience and low habitat priority.
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 63 The Mississippi Alluvial Plain and central portions of the Interior Low Plateau surrounding Nashville show both low landscape resilience and high TCSI scores, indicating that vegetation types and biomass production are likely to change in these regions and the characteristics of the surrounding landscapes do not necessarily provide a high level of connectivity or geophysical diversity. On the other hand, areas with lower TCSI scores and higher resilience are found in the Blue Ridge Mountains, Cumberland Mountains, and sections of the Cumberland Plateau and northern Ridge and Valley. These regions of the state are generally forested landscapes with a high degree of landscape complexity and connectivity, and the TCSI results indicate they may be less at risk for major vegetation type changes in the coming decades.
Areas in yellow demonstrate interesting differences in the information provided by the TCSI and landscape resilience scores. For example, forested areas along the Western Highland Rim of the Interior Low Plateau ecoregion score relatively high on landscape resilience (for detailed reference, see Figure 20), but according to the TCSI are projected to experience a higher risk of major vegetation type change.
Further consideration of this information in conjunction with more local site and field monitoring data may help resource managers develop strategies to protect the current intactness of the landscape, but deploy management activities that help facilitate species and habitat transitions and utilization of potentially-available microhabitats.
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 64 4.4.3.4 Overlay of Terrestrial Habitat Priorities, the Modified Terrestrial Climate Stress Index, and Resilient Sites for Terrestrial Conservation Figure 24 compares the results of the modified TCSI and Terrestrial Habitat Priorities overlay analysis for Tennessee with the Resilient Sites and Terrestrial Habitat Priorities overlay. Dark red indicates high-priority terrestrial habitat in areas identified as having low potential landscape resilience and face high ratings of TCSI stress. These include habitats in far western Tennessee along the Mississippi Alluvial Figure 23. Overlay of the modified TCSI and Resilient Sites for western (upper map) and eastern (lower map) Tennessee. The darkest red areas are those identified as having low resilience and high TCSI scores, while areas shaded in dark green are areas with high resilience and low TCSI scores. The yellow areas indicate places where there are either contradictory scores (e.g., high TCSI and high resilience) or where both scores are in the mid-range of their respective values.
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 65 Plain and parts of central Tennessee in the Interior Low Plateau, but there are also several such areas in agriculturally-fragmented parts of eastern Tennessee. These results suggest that current areas of high-priority terrestrial habitat in some regions of the state may face greater degrees of stress and change. On the other hand, places that are identified as resilient and face relatively low TCSI stress (shaded in dark green), such as the forests of the Cumberland and Smoky Mountains, appear especially promising as refugia.
This type of information is significant, as managers must make informed choices about what conservation outcomes may be feasible in different locations and what types of management and monitoring activities are likely to be most useful for managing change given longer-term and larger-scale regional projections.
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 66 Figure 24. Overlay of Climate Change Resilience/Terrestrial Habitat Priority sites with modified TCSI/Terrestrial Habitat Priority areas for western (upper map) and eastern (lower map) Tennessee. The darkest green areas are those identified as high habitat priorities, resilient sites, and having low TCSI scores, while areas shaded in dark red are high habitat priorities and rank as having low resilience and high TCSI.
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 67 5 CONCLUSION Tennessees fish and wildlife are treasured by the millions of people who call the state home or visit each year. With the growing recognition that climate change is playing an increasingly-significant role in the fate of the regions ecological systems, the state has an important opportunity to build on its conservation successes to date as well as incorporate new information that might affect its conservation goals.
The results of the climate change vulnerability assessment highlighted in this report will play a crucial role in helping Tennessee shape meaningful strategies to address the additional conservation challenges posed by climate change in its ongoing efforts to protect the states rich biodiversity. Ultimately, addressing climate change will help improve the forecast for Tennessees species and habitats and ensure that the many benefits they provide for society will endure for generations to come.
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 68 REFERENCES AFWA (Association of Fish and Wildlife Agencies). 2009. Voluntary Guidance to States to Incorporate Climate Change into State Wildlife Action Plans and Other Management Plans. Climate Change and Wildlife Action Plan Workgroup, Association of Fish and Wildlife Agencies, Washington, D.C.
AFWA. 2012. Best Practices for State Wildlife Action Plans: Voluntary Guidance to States for Revision and Implementation. Association of Fish and Wildlife Agencies, Washington, D.C.
Anderson, M.G., and C. Ferree. 2010. Conserving the stage: Climate change and the geophysical underpinnings of species diversity. PLoS ONE 5: e11554.doi:10.1371/journal.pone.0011554.
Anderson, J.A., S.M. Baker, G.L. Graham, M.G. Haby, S.G. Hall, L. Swann, W.C. Walton, and C.A.
Wilson. 2013. Effects of climate change on fisheries and aquaculture in the Southeast USA. Chapter 9 in:
Ingram, K., K. Dow, L. Carter, and J. Anderson (eds.). Climate of the Southeast United States:
Variability, Change, Impacts, and Vulnerability. Island Press, Washington, D.C.: 190-209.
Anderson, M.G., A. Barnett, M. Clark, C. Ferree, A.O. Sheldon, and J. Prince. 2014. Resilient Sites for Terrestrial Conservation in the Southeast Region. The Nature Conservancy, Eastern Conservation Science.
Bachelet, D., J. Lenihan, C. Daly, R. Neilson, D. Ojima, and W. Parton. 2001. MC1: A Dynamic Vegetation Model for Estimating the Distribution of Vegetation and Associated Ecosystem Fluxes of Carbon, Nutrients, and Water. USDA Forest Service, Pacific Northwest Station General Technical Report PNW-GTR-508.
Bachelet, D., R.P. Neilson, T. Hickler, R.J. Drapek, J.M. Lenihan, M.T. Sykes, B. Smith, S. Sitch, and K.
Thonicke. 2003. Simulating past and future dynamics of natural systems in the United States. Global Biogeochemical Cycles 17: doi:
Bachelet, D., T. Sheehan, and K. Ferschweiler. 2014. MC2 Dynamics at the 10 km (0.083 degree) Spatial Scale using AR4 Climate Projections. Final Report 12-JV-11221636-151. Conservation Biology Institute, Corvallis, OR.
Barrett, K., N.P. Nibblelink, and J.C. Maerz. 2014. Identifying priority species and conservation opportunities under future climate scenarios: amphibians in a biodiversity hotspot. Journal of Fish and Wildlife Management. Doi: 10.3996/022014-JFWM-015.
Blaustein, A.R., S.C. Walls, B.A. Bancroft, J.J. Lawler, C.L. Searle, and S.S. Gervasi. 2010. Direct and indirect effects of climate change on amphibian populations. Diversity 2: 281-313.
Blois, J.L., P.L. Zarnetske, M.C. Fitzpatrick, and S. Finnegan. 2013. Climate change and past, present, and future of biotic interactions. Science 341: 499-505.
Bruno, C., P. Hartger, L. Mendenhall, and E. Myron. 2012. Assessing the Potential Effects of Climate Change on Species in the Cumberland Piedmont Network of the National Park Service. Masters project
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 69 submitted in partial fulfillment of the requirements for the Master of Environmental Management degree in the Nicholas School of the Environment of Duke University, Durham, N.C.
Butler, P., K. Barrett, R. Cooper, H. Galbraith, K. Hall, H. Hamilton, J. OLeary, L. Sneddon, and B.
Young. 2014. Alternatives for Climate Change Vulnerability Assessment: Report to the Appalachian Landscape Conservation Cooperative. Final Report. NatureServe, Arlington, VA.
Byers, E. and S. Norris. 2011. Climate Change Vulnerability Assessment of Species of Concern in West Virginia. West Virginia Division of Natural Resources, Elkins, WV.
Carey, C., and M.A. Alexander. 2003. Climate change and amphibian declines: Is there a link? Diversity and Distributions 9: 111-121.
Chagnon, S.A., D. Chagnon, and T.R. Karl. 2006. Temporal and spatial characteristics of snowstorms in the contiguous United States. Journal of Applied Meteorology and Climatology 45: 1141-1155.
Chen, I.-C., J.K. Hill, R. Ohlemüller, D.B. Roy, and C.D. Thomas. 2011. Rapid shifts of species associated with high levels of climate warming. Science 333: 1024-1026.
Clark, M.E., K.A. Rose, D.A. Levine, and W.W. Hargrove. 2001. Predicting climate change effects on Appalachain trout: combining GIS and individual-based modeling. Ecological Applications 11: 161-178.
Colvin, R., P. English, and T. Hannah. 2013. Climate Change Vulnerability Assessment Report for High Priority Wildlife Species in West Tennessee. Tennessee Wildlife Resources Association and Mississippi State University.
Dale, V.H., L.A. Joyce, S.G. McNulty, and R.P. Neilson 2000. The interplay between climate change, forests, and disturbances. Science of the Total Environment 262: 201-204.
Dale, V.H., L.A. Joyce, S. McNulty, R.P. Neilson, M.P. Ayres, M.D. Flannigan, P.J. Hanson, L.C. Irland, A.E. Lugo, C.J. Peterson, D. Simberloff, F.J. Swanson, B.J. Stocks, and B.M. Wotton. 2001. Climate change and forest disturbances. BioScience 51: 723-734.
Dale, V.H., K.O. Lannom, M.L. Tharp, D.G. Hofges, and J. Fogel. 2009. Effects of climate change, land-use change, and invasive species on the ecology of the Cumberland forests. Canadian Journal of Forest Resources 39: 467-480.
Dale, V.H., M.L. Tharp, K.O. Lannom, and D.G. Hodges. 2010. Modeling transient response of forests to climate change. Science of the Total Environment 408: 1888-1901.
Dubois, N., A. Caldas, J. Boshoven, and A. Delach. 2011. Integrating Climate Change Vulnerability Assessments into Adaptation Planning: A Case Study Using the NatureServe Climate Change Vulnerability Index to Inform Conservation Planning for Species in Florida. Defenders of Wildlife, Washington, D.C.
Duerr, D.A., and P.A. Mistretta. 2013. Invasive pests - insects and diseases. Chapter 16 in: D.N. Wear and J.G. Greis (eds.). The Southern Forest Futures Project. Technical Report. USDA Forest Service, Southern Research Station, Ashville, N.C.: 457-491.
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 70 EPRI (Electric Power Research Institute). 2009. Potential Impact of Climate Change on Natural Resources in the Tennessee Valley Authority Region. Palo Alto, CA.
Evans, A.M., and T.G. Gregoire. 2007. A geographically variable model of hemlock woolly adelgid spread. Biological Invasions 9: 369-382.
Fey, S.B., and K.L. Cottingham. 2011. Linking biotic interactions and climate change to the success of exotic Daphnia lumholtzi. Freshwater Biology 56: 2196-2209.
Flannigan, M.D., B.J. Stocks, and B.M. Wotton. 2000. Climate change and forest fires. Science of the Total Environment 262: 221-229.
Furedi, M., B. Leppo, M. Kowalski, T. Davis, and B. Eichelberger. 2011. Identifying Species in Pennsylvania Potentially Vulnerable to Climate Change. Pennsylvania Natural Heritage Program, Western Pennsylvania Conservancy, Pittsburgh, PA.
Gan, J.B. 2004. Risk and damage of southern pine beetle outbreaks under global climate change. Forest Ecology and Management 191: 61-71.
Girvetz, E.H., C. Zganjar, G.T. Raber, E.P. Maurer, P. Kareiva, and J.J. Lawler. 2009. Applied climate-change analysis: The ClimateWizard tool. PLoS ONE 4: r8320. Doi: 10.1371/journal.pone.0008320.
Glick, P., B.A. Stein, and N.A. Edelson (eds.). 2011. Scanning the Conservation Horizon: A Guide to Climate Change Vulnerability Assessment. National Wildlife Federation, Washington, D.C.
Gonzalez, P., R.P. Neilson, J.M. Lenihan, and R.J. Drapek. 2010. Global patterns in the vulnerability of ecosystems to vegetation shifts due to climate change. Global Ecology and Biogeography 19: 755-768.
Graham, T.B. 2013. Climate change and ephemeral pool ecosystems: Potholes and vernal pools as potential indicator systems. Impact of Climate Change and Land Use in the Southeastern United States.
http://geochange.er.usgs.gov/sw/impacts/biology/vernal/ (accessed March 3, 2015).
Groisman, P.Y. and R.W. Knight. 2008. Prolonged dry episodes over the conterminous United States:
new tendencies emerging during the last 40 years. Journal of Climate 21: 1850-1862.
Hansen, A.J., R.P. Nielson, V.H. Dale, C.H. Flather, L.R. Iverson, D.J. Currie, S. Shafer, R. Cook, and P.J. Bartlein. 2001. Global change in forests: Responses of species, communities, and biomes. BioScience 51: 765-779.
Hayhoe, K., B. Jones, and J. Gross. 2011. IV. Peering into the future: Climate and ecological models. In:
P. Glick, B.A. Stein, and N.A. Edelson (eds.). Scanning the Conservation Horizon: A Guide to Climate Change Vulnerability Assessment. National Wildlife Federation, Washington, D.C.
Hopkinson, C.S., A.P. Covich, C.B. Craft, K. DeLong, T.W. Doyle, N. Flanagan, M.C. Freeman, E.R.
Herbert, A. Mehring, J.E. Mohan, C.M. Pringle, and C.J. Richardson. 2013. The effects of climate change on natural ecosystems of the Southeast USA. Chapter 11 in: Ingram, K., K. Dow, L. Carter, and J.
Anderson (eds.). Climate of the Southeast United States: Variability, Change, Impacts, and Vulnerability.
Island Press, Washington, D.C.: 237-270.
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 71 Hoving, C.L., Y.M. Lee, P.J. Badra, and B.J. Klatt. 2013. Changing Climate, Changing Wildlife: A Vulnerability Assessment of 400 Species of Greatest Conservation Need and Game Species in Michigan.
Michigan Department of Natural Resources, Wildlife Division, Lansing, MI.
Howey, C.A.F., and S.A. Dinkelacker. 2009. Habitat selection of the alligator snapping turtle (Macrochelys temminckii) in Arkansas. Journal of Herpetology 43: 589-596.
Iverson, L.R., and A.M. Prasad. 2001. Potential changes in tree species richness and forest community types following climate change. Ecosystems 4: 186-199.
Iverson, L.R., and A.M. Prasad. 2002. Potential tree species shifts with five climate change scenarios in the Eastern United States. Forest Ecology and Management 155: 205-222.
Iverson, L.R., A.M. Prasad, S.N. Matthews, and M. Peters. 2008. Estimating potential habitat for 134 eastern US tree species under six climate scenarios. Forest Ecology and Management 254: 390-406.
Ingram, K., K. Dow, L. Carter, and J. Anderson (eds.). 2013. Climate of the Southeast United States:
Variability, Change, Impacts, and Vulnerability. Island Press, Washington, D.C.
Innes, R.J. 2010. Scolopax minor. In: Fire Effects Information System [Online]. U.S. Department of Agricuture, Forest Service, Rocky Mountain Research Station, Fire Sciences Laboratory (Producer).
Available: http://www.fs.fed.us/database/feis/ (accessed February 5, 2015).
IPCC (Intergovernmental Panel on Climate Change). 2007. Climate Change 2007: Synthesis Report.
Contribution of Working Groups I, II, and III to the Fourth Assessment Report of the Intergovernmental Panel on Climate Change [Core Writing Team, Pachauri, R.K., and Reisinger, A. (eds.)]. Geneva, Switzerland, 104 pp.
Jacob, D.J., and D.A. Winner. 2009. Effects of climate change on air quality. Atmospheric Environment 43: 51-63.
Joyce, L.A., and C.H. Flather. 2015. Briefing paper (Analysis of Vegetation Type Changes in Tennessee Using the MC2 Model, A1B Scenario) and email exchanges on file at the U.S. Forest Service, Rocky Mountain Research Station, Fort Collins, CO; RMRS-4853 files.
Karetinov, D., J. Fisler, S. Williamson, B. Bell, M. Ruth, K. Ross, and D. Irani. 2008. Economic Impacts of Climate Change on Tennessee. Center for Integrative Environmental Research, University of Maryland, College Park, MD.
Keeley, J., and P. Zedler. 1998. Characterization and global distribution of vernal pools. Ecology, Conservation, and Management of Vernal Pool Ecosystems - Proceedings from a 1996 Conference.
California Native Plant Society, Sacramento, CA.
Kelley, J.R., Jr., and S.J. Williamson. 2008. American Woodcock Conservation Plan. Wildlife Management Institute, Washington, D.C.
Kelly, A.E., and M.L. Goulden. 2008. Rapid shifts in plant distribution with recent climate change.
Proceedings of the National Academy of Sciences 105: 11823-11826.
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 72 Kershner, J., and E. Mielbrecht. 2012. A Climate-Informed Conservation Blueprint for the Greater Puget Sound Ecoregion. EcoAdapt and Geos Institute.
Knight, R.R., J.C. Murphy, W.J. Wolfe, C.F. Saylor, and A.K. Wales. 2014. Ecological limit functions relating to fish community response to hydrologic departures of the ecological flow regime in the Tennessee River basin, United States. Ecohydrology 7: 1262-1280.
Kunkel, K.E., L.E. Stevens, S.E. Stevens, L. Sun, E. Janssen, D. Weubbles, C.E. Konrad, C.M.
Fuhrmann, B.D. Keim, M.C. Kruk, A. Billot, H. Needham, M. Shafer, and J.G. Dobson. 2013. Regional Climate Trends and Scenarios for the U.S. National Climate Assessment. Part 2: Climate of the Southeast United States. NOAA Technical Report NESDIS 142-2.
Laerm, J., W.M. Ford, and B.R. Chapman. 2007. American water shrew (Sorex palustris). In: M.K. Trani, W.M. Ford, and B.R. Chapman (eds.). The Land Managers Guide to Mammals of the South. U.S. Forest Service, Southern Region, Atlanta, GA, and The Nature Conservancy, Southeastern Region, Durham, N.C.: 109-112.
Lenihan, J.M., D. Bachelet, R.P. Neilson, and R.J. Drapek. 2008. Simulated response of conterminous United States ecosystems to climate change at different levels of fire suppression, CO2, and growth response to CO2. Global and Planetary Change 64: 16-25.
Lennon, J.T., V.H. Smith, and K. Williams. 2001. Influence of temperature on exotic Daphnia lumholtzi and implications for invasion success. Journal of Plankton Research 23: 425-433.
Linzey, A.V. & NatureServe (Hammerson, G., Whittaker, J.C. & Norris, S.J.) 2008. Microtus chrotorrhinus. The IUCN Red List of Threatened Species. Version 2014.3. www.iucnredlist.org (accessed March 18, 2015).
Loarie, S.R., P.B. Duffy, H. Hamilton, G.P. Asner, C.B. Field, and D.D. Ackerly. 2009. The velocity of climate change. Nature 462: 1052-1055.
Marion, D.A., G. Sun, P.V. Caldwell, C.M. Miniat, Y. Ouyang, D.M. Amatya, B.D. Clinton, P.A.
Conrads, S.G. Laird, Z. Dai, J.A. Clingenpeel, Y. Liu, E.A. Roehl, Jr., J.A. Moore Meyers, and C. Trettin.
2014. 9. Managing Forest Water Quantity and Quality under Climate Change. In: J.M. Vose and K.D.
Klepzig (eds.). Climate Change Adaptation and Mitigation Management Options: A Guide for Natural Resource Managers in Southern Forest Ecosystems. CRC Press, Boca Raton, FL: 249-305.
McNulty, S., P. Caldwell, T.W. Doyle, K. Johnsen, Y. Liu, J. Mohan, J. Prestemon, and G. Sun. 2013.
Forests and climate change in the Southeast USA. Chapter 8 in: Ingram, K., K. Dow, L. Carter, and J.
Anderson (eds.). Climate of the Southeast United States: Variability, Change, Impacts, and Vulnerability.
Island Press, Washington, D.C.: 165-189.
Meyer, R. 2006. Aimophila aestivalis. In: Fire Effects Information System, [Online]. U.S. Department of Agriculture, Forest Service, Rocky Mountain Research Station, Fire Sciences Laboratory (Producer).
Available: http://www.fs.fed.us/database/feis/ (accessed February 5, 2015).
Milanovich, J.R., W.E. Peterman, N.P. Nibblelink, and J.C. Maerz. 2010. Projected loss of a salamander diversity hotspot as a consequence of projected global climate change. PLoS ONE 5, e12189.
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 73 Mitchell, R.J., Y. Liu, J.J. OBrien, K.J. Elliott, G. Starr, C.F. Miniat, and J.K. Hiers. 2014. Future climate and fire interactions in the southeastern region of the United States. Forest Ecology and Management, http://dx.doi.org/10.1016/j.foreco.2013.12.003 (accessed May 13, 2015).
National Fish, Wildlife and Plants Climate Adaptation Partnership. 2012. National Fish, Wildlife and Plants Climate Adaptation Strategy. Association of Fish and Wildlife Agencies, Council on Environmental Quality, Great Lakes Indian Fish and Wildlife Commission, National Oceanic and Atmospheric Administration, and U.S. Fish and Wildlife Service, Washington, D.C.
Nakicenovic, N., and R. Swart. 2000. Special report on Emissions Scenarios: A Special Report of Working Group III of the Intergovernmental Panel on Climate Change. Cambridge University Press, Cambridge, U.K.
NWF (National Wildlife Federation) and NatureServe. 2014 (draft). Habitat Vulnerabilities to Climate Change in the Appalachian Landscape Conservation Cooperative. National Wildlife Federation and NatureServe, Washington, D.C.
Palmer, S.R., and J.P. Wisby. 2015. Database Development and Spatial Analyses in Support of Tennessees State Wildlife Action Plan. The Nature Conservancy, Nashville, TN.
Paradis, A., J. Elkinton, K. Hayhoe, and J. Buonaccorsi. 2006. Role of winter temperature and climate change on the survival and future range expansion of the hemlock woolly adelgid (Adelges tsugae) in eastern North America. Mitigation and Adaptation Strategies for Global Change: doi: 10.1007/s11027-007-9127-0.
Pearson, R.G., J.C. Stanton, K.T. Shoemaker, M.E. Aiello-Lammens, P.J. Ersts, N. Horning, D.A.
Fordham, C.J. Raxworthy, H.Y. Ryu, J. McNees, and R. Akçakaya. 2014. Life history and spatial traits predict extinction risk due to climate change. Nature Climate Change 4: 217-221.
Pocewicz, A., H.E. Copeland, M.B. Grenier, D.A. Keinath, and L.M. Waskoviak. 2014. Assessing the Future Vulnerability of Wyomings Terrestrial Wildlife Species and Habitats. Report prepared by The Nature Conservancy, Wyoming Game and Fish Department and Wyoming Natural Diversity Database.
Poorter, H.C., and M.L. Navas. 2003. Plant growth and competition at elevated CO2: On winners, losers, and functional groups. New Phytologist 157: 175-198.
Prasad, A.M., L.R. Iverson, S. Matthews, and M. Peters. 2007-ongoing. A Climate Change Atlas for 134 Forest Tree Species of the Eastern United States [database]. USDA Forest Service, Northern Research Station, Delaware, OH. http://www.nrs.fs.fed.us/atlas/tree (accessed June 18, 2015).
Ring, R.M., E.A. Spencer, and K.S. Walz. 2013. Vulnerability of 70 Plant Species of Greatest Conservation Need to Climate Change in New Jersey. NatureServe, Arlington, VA.
Root, T.L., and S.H. Schneider. 2006. Conservation and climate change: The challenges ahead.
Conservation Biology 20: 706-708.
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 74 Rosenbaum, P.A., J.M. Robertson, and K.R. Zamudio. 2007. Unexpectedly low genetic divergences among populations of the threatened bog turtle (Glyptemys muhlenbergii). Conservation Genetics 8: 331-342.
Schlesinger, M.D., J.D. Corser, K.A. Perkins, and E.L. White. 2011. Vulnerability of At-risk Species to Climate Change in New York. New York Natural Heritage Program, Albany, NY.
Simberloff, D. 2000. Global climate change and introduced species in United States forests. Science of the Total Environment 262: 253-261.
Small-Lorenz, S., L.A. Culp, T.B. Ryder, T.C. Will, and P.P. Marra. 2013. A blind spot in climate change vulnerability assessments. Nature Climate Change 3: 91-93.
Stanturf, J.A., and S.L. Goodrick. 2013. Chapter 17: Forests. In. D.N. Wear and J.G. Greis (eds.). The Southern Forest Futures Project. Technical Report. USDA Forest Service, Southern Research Station, Ashville, N.C.: 509-542.
Staudinger, M.D., S.L. Carter, M.S. Cross, N.S. Dubois, J.E. Duffy, C. Enquist, R. Griffis, J.J. Hellmann, J.J. Lawler, J. OLeary, S.A. Morrison, L. Sneddon, B.A. Stein, L.M. Thompson, and W. Turner. 2013.
Biodiversity in a changing climate: A synthesis of current and projected trends in the U.S. Frontiers in Ecology and the Environment 11: 465-473.
Steel, Z.L., M. Wilkerson, P. Grof-Tisza, and K. Sulzner. 2011. Assessing Species and Area Vulnerability to Climate Change for the Oregon Conservation Strategy: Willamette Valley Ecoregion. Conservation Management Program, University of California, Davis.
Stein, B.A., L.S. Kutner, and J.S. Adams (eds.). 2000. Precious Heritage: The Status of Biodiversity in the United States. Oxford University Press, New York.
Stein, B.A., P. Glick, N.Edelson, and A. Staudt (eds.). 2014. Climate-Smart Conservation: Putting Adaptation Principles into Practice. National Wildlife Federation, Washington, D.C.
Sun, G., P. Caldwell, A. Noormets, E. Cohen, S.G. McNulty, E. Treasure, J.C. Domec, Q. Mu, J. Xiao, R.
John, and J. Chen. 2011. Upscaling key ecosystem functions across the conterminous United States by a water-centric ecosystem model. Journal of Geophysical Research 116, G00J05; doi:
10.1029/2010JG001573.
Sun, G.E., S.B. McLaughlin, J.H. Porter, J. Uddling, P.J. Mullholland, M.B. Adams, and N. Pederson.
2012. Interactive influences of ozone and climate on streamflow of forested watersheds. Global Change Biology 18: 3395-3409.
Sun, G., S. Arumugam, P.V. Caldwell, P.A. Conrads, A.P. Covich, J. Cruise, J. Feldt, A.P. Georgakakos, R.T. McNider, S.G. McNulty, D.A. Marion, V. Misra, T.C. Rasmussen, L. Romolo, and A. Terando.
2013. Impacts of climate change and variability on water resources in the Southeast USA. Chapter 10 in:
Ingram, K., K. Dow, L. Carter, and J. Anderson (eds.). Climate of the Southeast United States:
Variability, Change, Impacts, and Vulnerability. Island Press, Washington, D.C.: 210-236.
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 75 Szabo, K. 2012. CCVI Results Sorted by Taxonomic Group/Scientific Name. Nevada Natural Heritage Program, Carson City, NV.
Tennessee Climatological Service. 2014. Climate of Tennessee. URL:
https://ag.tennessee.edu/climate/Pages/climatedataTN.aspx (accessed September 5, 2014).
Treasure, E.A., E. Cohen, S.G. McNulty, and J.A. Moore Myers. 2008. Vulnerability of the Southeastern United States to Climate Change. USDA Forest Service Southern Global Change Program.
TWRA (Tennessee Wildlife Resources Agency). 2005. Tennessees Comprehensive Wildlife Conservation Strategy. Tennessee Wildlife Resources Agency, Nashville, TN.
TWRA. 2009. Climate Change and Potential Impacts to Wildlife in Tennessee. An Update to Tennessees State Wildlife Action Plan. Tennessee Wildlife Resources Agency, Nashville, TN.
TWRA. 2014. Strategic Plan 2014-2020. The Tennessee Wildlife Resources Agency, Nashville, TN.
TWRA. 2015. Tennessee State Wildlife Action Plan 2015. The Tennessee Wildlife Resources Agency, Nashville, TN.
Urban, M.C. 2015. Accelerating extinction risk from climate change. Science 438: 571-573.
USAID (United States Agency for International Development). 2014. Spatial Climate Change Vulnerability Assessments: A Review of Data, Methods, and Issues. African and Latin American Resilience to Climate Change Project, USAID, Washington, D.C.
USDA (U.S. Department of Agriculture) Forest Service. 2012. Future of Americas Forests and Rangelands: Forest Service 2010 Resources Planning Act Assessment. Gen. Tech. Rep. WO-87. U.S.
Forest Service, U.S. Department of Agriculture, Washington, D.C.
USDA Forest Service. In press. Interim Update of the 2010 Renewable Resource Planning Act Assessment. Gen. Tech. Rep. WO-000. USDA Forest Service, Washington, D.C.
USGS (U.S. Geological Survey). 2015. Endangered Flying Squirrel Relegated to Living on Sky-Islands.
http:// http://www.usgs.gov/newsroom/article.asp?ID=4147#.VQmtfDbn_cs (accessed March 18, 2015).
Walk, J., S. Hagen, and A. Lange. 2011. Adapting Conservation to a Changing Climate: An Update to the Illinois Wildlife Action Plan. Report to the Illinois Department of Natural Resources. Prepared by the Illinois Chapter of The Nature Conservancy, Chicago, IL.
Walls, S.C., W.J. Barichivich, and M.E. Brown. 2013. Drought, deluge, and declines: the impact of precipitation extremes on amphibians in a changing climate. Biology 2: 399-418.
Walther, G.-R. 2010. Community and ecosystem responses to recent climate change. Philosophical Transactions of the Royal Society B 365: 2019-2024.
Wang, H., R. Fu, A. Kumar, and W. Li. 2010. Intensification of summer rainfall variability in the southeastern United States during recent decades. Journal of Hydrometeorology 11: 1007-1018.
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 76 Washington WHCWG (Wildlife Habitat Connectivity Working Group). 2010. Washington Connected Landscapes Project: Statewide Analysis. Washington Department of Fish and Wildlife and Washington Department of Transportation, Olympia, WA.
Weiss, S.B., D.D. Murphy, and R.R. White. 1988. Sun, slope, and butterflies: Topographic determinants of habitat quality for Euphydryas editha bayensis. Ecology 69: 1386.
Young, B., E. Byers, K. Gravuer, K. Hall, G. Hammerson, and A. Redder. 2011. Guidelines for using the NatureServe Climate Change Vulnerability Index, Release 2.1. NatureServe, Arlington, VA.
Young, B.E., K.R. Hall, E. Byers, K. Gravuer, G. Hammerson, A. Redder, and K. Szabo. 2012. Rapid assessment of plant and animal vulnerability to climate change. In: J. Brodie, E. Post, and D. Doak (eds.).
Wildlife Conservation in a Changing Climate. University of Chicago Press, Chicago, IL: 129-150.
Young, B.E., N.S. Dubois, and E.L. Rowland. 2014. Using the climate change vulnerability index to inform adaptation planning: Lessons, innovations, and next steps. Wildlife Society Bulletin. doi:
10.1002/wsb.478.
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 77 APPENDIX A. DESCRIPTIVE TABLES FOR THE CLIMATE CHANGE VULNERABILITY INDEX (CCVI)
The CCVI uses a scoring system that integrates projected direct exposure to climate change (Table 12) with three sensitivity factors: 1) indirect exposure to climate change (Table 13); 2) species-specific sensitivity factors (Table 14); and, where available, 3) documented responses to climate change (Table 15). A numeric sum of the scores for each component is then converted into a categorical score by comparing it to threshold values (Table 16).
Table 12. CCVI direct exposure factors This category allows for analysis of the percentage of a species range that is likely to be associated with specific changes in temperature or precipitation/moisture conditions under scenarios of modeled future climate change. Typically, this data is at a relatively-coarse scale using data from the tool ClimateWizard.
Temperature The percent of a species range in five categories of increasing temperature based on ClimateWizard projections for 2050.
Typically, assessments are based on the results of the Model Ensemble Average for the IPCC SRES A1B emissions scenario.
>5.5° F (3.1° C) warmer (compared to 1961-1990 baseline) 5.1-5.5° F (2.8-3.1° C) warmer 4.5-5.0° F (2.5-2.7° C) warmer 3.9-4.4° F (2.2-2.4° C) warmer
<3.9° F (2.2° C) warmer Moisture The percent of species range in six categories of changing moisture regime based on ClimateWizard projections for 2050.
These figures represent the predicted change in annual moisture based on the Hamon AET:PET Moisture Metric (the ratio of actual evapotranspiration, or AET, to potential evapotransporation, PET), rather than changes in precipitation. Negative values indicate net drying: no areas of the contiguous U.S. are predicted to increase in annual moisture.
<-0.119 (a significant change)
-0.097 - -0.119
-0.074 - -0.096
-0.051 - -0.073
-0.028 - -0.050
>-0.028 (an insignificant change)
Table 13. CCVI indirect exposure factors Within the CCVI framework, indirect exposure factors are those changes that are not directly associated with changing climate conditions (e.g., temperature and precipitation) but, rather, those that may result from such direct changes. This category also includes several factors that one might consider elements affecting the adaptive capacity of a particular species (e.g., physical barriers to dispersal). This is also where one might consider any ancillary effects that human response to climate change might create. These may be positive, such as protection of forests or other natural areas to enhance carbon sequestration, or negative, such as developing wind farms in important bird or bat migration corridors or damming rivers for new freshwater reservoirs.
Exposure to sea-level rise This factor comes into play only in the case that all or a portion of the range within the assessment area may be subject to the effects of a 0.5-1m sea-level rise and the consequent influence of storm surges.
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 78 Distribution relative to natural barriers This factor assesses the degree to which natural (e.g., topographic, geographic, ecological) barriers limit a species ability to shift its range in response to climate change. Species for which barriers would inhibit distributional shifts with climate change-caused shifts in climate envelopes likely are more vulnerable to climate change than are species whose movements are not affected by barriers.
Distribution relative to anthropogenic barriers This factor assesses the degree to which anthropogenic barriers (e.g., roads, urban areas or agricultural areas, seawalls, dams, and culverts) limit a species ability to shift its range in response to climate change. Species for which barriers would inhibit distributional shifts with climate change-caused shifts in climate envelopes likely are more vulnerable to climate change than are species whose movements are not affected by barriers.
NatureServe suggests assessing the intensity of landuse in the assessment area and in the direction of expected species movements using the Wildland-Urban Interface of the Silvis Lab. Users can also use the National Land Cover Dataset from the Multi-Resolution Land Characteristics Consortium.
Predicted impacts of land use changes due to human response to climate change Strategies designed to mitigate or adapt to climate change have the potential to affect very large areas of land, and the species that depend on these areas, in both positive and negative ways. This factor is not intended to capture habitat loss or destruction due to other on-going human activities, which are already considered in existing conservation status ranks.
Table 14. CCVI sensitivity factors CCVI sensitivity factors refer to characteristics of the particular species being assessed. Some of the factors may, in fact, be considered elements of adaptive capacity as described previously, but here they are relevant to more intrinsic elements of adaptive capacity. Extrinsic factors (e.g., anthropogenic or natural barriers to dispersal) are considered in the previous category of assessment variables.
Dispersal and movements This pertains to known or predicted dispersal or movement capabilities and characteristics and ability to shift location in the absence of barriers as conditions change over time as a result of climate change. In general, species with poor dispersal ability are likely to be more vulnerable to climate change than those that regularly disperse or move long distances. Specific barriers to dispersal (both natural and anthropogenic) are considered as elements of indirect exposure (above).
Sensitivity to changes in temperature This pertains to the breadth of temperature conditions within which a species is known to be capable of reproducing, feeding, growing, or otherwise existing.
Factors evaluated include the historical thermal niche (exposure to past variations in temperature, as approximated by mean annual precipitation variation across occupied cells in the assessment area) and the current physiological thermal niche.
Sensitivity to changes in precipitation, hydrology, and moisture regime This pertains to the breadth of moisture conditions within which a species is known to exist. Factors evaluated include the historical hydrologic niche (exposure to past variations in precipitation) and current hydrologic niche (which pertains to a species dependence on a narrowly-defined precipitation/hydrologic regime, including strongly seasonal precipitation patterns and/or specific aquatic/wetland habitats or localized moisture conditions that might be vulnerable to loss or reduction with climate change).
Dependence on a specific disturbance regime likely to be affected by climate change This pertains to a species response to specific disturbance regimes such as fires, floods, severe winds, pathogen outbreaks, or similar events. It includes disturbances that affect species directly as well as those that affect species via abiotic aspects of habitat quality.
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 79 Dependence on ice, ice-edge, or snow-cover habitats This pertains to a species dependence on habitats associated with ice or snow throughout the year or seasonally.
Restriction to uncommon geological features or derivatives This pertains to a species need for a particular soil/substrate, geology, water chemistry, or specific physical feature (e.g., caves, cliffs) for reproduction, feeding, growth, or otherwise existing for one or more portions of the life cycle. It focuses on the commonness of suitable conditions for the species on the landscape, as indicated by the commonness of the features themselves combined with the degree of the species restriction to them.
Dependence on other species to generate habitat Habitat here refers to any habitat (e.g., for reproduction, feeding, hibernation, seedling establishment, etc.) necessary for completion of the life cycle, including those only used on a seasonal basis.
Dietary versatility (animals only)
This pertains to the diversity of food types consumed by animal species. Dietary specialists are more likely to be negatively affected by climate change than species that readily switch among different food types.
Pollinator versatility (plants only)
This pertains to the degree to which plants are dependent on one or multiple species for pollination.
Dependence on other species for propagule dispersal This can be applied to plants or animals (e.g., fruit dispersal by animals). If the propagule-dispersing species is vulnerable to climate change, the dependent species is likely to be so as well.
Other interspecific interaction factors This may include factors other than habitat, seedling establishment, diet, pollination, or propagule dispersal, such as mutualism, parasitism, predator-prey relationships, etc.
Measured genetic variation Species with less standing genetic variation will be less able to adapt because the appearance of beneficial mutations is not expected to keep pace with the rate of 21st century climate change.
Occurrence of bottlenecks in recent evolutionary history In the absence of range wide genetic variation information, this factor can be used to infer whether reductions in species-level genetic variation that would potentially impede its adaptation to climate change may have occurred.
Phenological response to changing seasonal temperature or precipitation dynamics Recent research suggests that some phylogenetic groups are declining due to lack of response to changing annual temperature dynamics (e.g., earlier onset of spring, longer growing season).
Table 15. Documented or modeled response to climate change This category allows for inclusion of information from supplemental studies, if available.
Documented response to recent climate change This addresses the degree to which a species is known to have responded to recent climate change based on published accounts in peer-reviewed literature. For example, some species have shifted ranges or shown phenological changes. Species already experiencing change are important sentinels for future impacts.
Modeled future (2050) change in range or population size Models should be developed based on reasonably accurate locality data using algorithms that are supported by peer-reviewed literature. Relative vulnerability depends on the extent to which species distribution and/or population is projected to change relative to historic or current conditions.
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 80 Overlap of modeled future (2050) range with current range If the range disappears or declines >70% within the assessment area, such that the previous factor is coded as Greatly Increase Vulnerability, this factor should be skipped to avoid double-counting in the scoring.
Occurrence of protected areas in modeled future distribution Protected area refers to existing parks, refuges, wilderness areas, and other designated conservation areas that are relatively invulnerable to outright habitat destruction from human activities and that are likely to provide suitable conditions for the existence of viable populations.
Table 16. The CCVI final score ranking Vulnerability rankings are based on numeric scores calculated from a combination of exposure and the individual risk factors (i.e., indirect exposure, sensitivity, and documented response), as described in detail in Young et al. (2011). For the individual risk factors, numeric values are applied as follows:
Somewhat Increase (SI) = 1.0; Increase (Inc) = 2.0; Greatly Increase (GI) = 3.0; Somewhat Decrease (SD) = -1.0; and Decrease (Dec) = -2.0. Factors for which there are no data or that are scored as neutral receive a zero. If a factor is scored at multiple levels (e.g., both Somewhat Increase and Increase), the index uses an average of values for these levels. The value for each risk factor is then weighted by exposure to calculate a subscore for the factor. These subscores are then summed to determine a final score of relative vulnerability as follows:
Extremely Vulnerable (EV)
Abundance and/or range extent within geographical area assessed extremely likely to substantially decrease or disappear by 2050.
Highly Vulnerable (HV)
Abundance and/or range extent within geographical area assessed likely to decrease significantly by 2050.
Moderately Vulnerable (MV)
Abundance and/or range extent within geographical area assessed likely to decrease by 2050.
Not Vulnerable/Presumed Stable (PS)
Available evidence does not suggest that abundance and/or range extent within the geographical area assessed will change (increase/decrease) substantially by 2050. Actual range boundaries may change.
Not Vulnerable/Increase Likely (IL)
Available evidence suggests that abundance and/or range extent within the geographical area assessed is likely to increase by 2050.
Insufficient Evidence (IE)
Available information about a species vulnerability is inadequate to calculate an Index score.
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 81 APPENDIX B. DIRECT EXPOSURE FACTORS FOR SELECTED TENNESSEE SPECIES Projections for temperature and moisture changes across the state were derived from ClimateWizard (Girvetz et al. 2009, www.climatewizard.org) and are based on the IPCC Fourth Assessment Report (IPCC 2007) for a 16-model Ensemble Average under the IPCC medium emissions scenario A1B (the scenario recommended for use in the CCVI, Young et al. 2011). Projected temperatures calculated across Tennessee ranged from a 3.9 to 4.5°F increase by the 2050s, as shown in Figure 25. The predicted net change in moisture, which are derived from the Hamon AET:PET Moisture Metric (the ratio of actual evaporation, AET, to potential evapotranspiration, PET), showed net drying ranging from -0.119 to >-
0.028 across the state, with the majority of the area falling within the -0.096 to -0.073 range (see Figure 26).
Figure 25. Regional map showing projected change in annual temperature by the 2050s (relative to the 1960-1991 reference period) based on the Ensemble Average under the SRES A1B emissions scenario. Map is based on data and analyses from ClimateWizard (www.climatewizard.org).
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 82 Figure 26. Continental map showing projected net-drying conditions by mid-century (relative to the 1960-1991 reference period) based on the Ensemble Average under the SRES A1B emissions scenario. Map is based on data and analyses from ClimateWizard (www.climatewizard.org).
Table 17 highlights the percentage of the particular species range in Tennessee that is projected to be exposed to the various temperature and moisture changes, as calculated using ClimateWizard data. As reflected by the figures, there is greater variation in moisture changes across the state than temperature.
The table is sorted by taxonomic group and common name.
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 83 Table 17. Direct CCVI exposure factors for selected Tennessee CGN species Exposure to Temperature Variables Exposure to Moisture Variables Scientific Name Common Name A >5.5F A 5.1F A 4.5F A 3.9F A <3.9F
< -0.119
-0.119
-0.096
-0.073
-0.05
>-0.028 Mammals Neotoma magister Allegheny woodrat 0
0 0
100 0
0 0
0 100 0
0 Sorex palustris American water shrew 0
0 0
100 0
0 0
0 100 0
0 Glaucomys sabrinus coloratus Carolina northern flying squirrel 0
0 0
100 0
0 0
0 0
70 30 Myotis leibii Eastern small-footed bat 0
0 0
100 0
0 0
60 40 0
0 Myotis grisescens Gray bat 0
0 0
100 0
0 0
45 55 0
0 Parascalops breweri Hairy-tailed mole 0
0 0
100 0
0 0
0 100 0
0 Myotis sodalis Indiana bat 0
0 0
100 0
0 0
40 60 0
0 Mustela nivalis Least weasel 0
0 0
100 0
0 0
0 100 0
0 Myotis septentrionalis Northern myotis 0
0 0
100 0
0 0
50 50 0
0 Corynorhinus rafinesquii Rafinesque's big-eared bat 0
0 0
100 0
0 0
60 40 0
0 Tamiasciurus hudsonicus Red squirrel 0
0 0
100 0
0 0
0 0
70 30 Sorex fumeus Smoky shrew 0
0 0
100 0
0 0
0 100 0
0 Microtus chrotorrhinus carolinensis Southern rock vole 0
0 0
100 0
0 0
0 0
90 10 Condylura cristata Star-nosed mole 0
0 0
100 0
0 0
0 95 5
0 Napaeozapus insignis Woodland jumping mouse 0
0 0
100 0
0 0
0 100 0
0 Birds Botaurus lentiginosus American bittern 0
0 100 0
0 0
0 100 0
0 0
Pluvialis dominica American golden plover 0
0 100 0
0 0
0 80 20 0
0 Scolopax minor American woodcock 0
0 100 0
0 0
0 80 20 0
0 Anhinga anhinga Anhinga 0
0 100 0
0 0
0 100 0
0 0
Aimophila aestivalis Bachman's sparrow 0
0 100 0
0 0
0 80 20 0
0 Riparia riparia Bank swallow 0
0 100 0
0 0
0 80 20 0
0 Tyto alba Barn owl 0
0 100 0
0 0
0 80 20 0
0 Vireo bellii Bell's vireo 0
0 100 0
0 0
0 100 0
0 0
Thryomanes bewickii Bewick's wren 0
0 100 0
0 0
0 100 0
0 0
Vermiforma pinus Blue-winged warbler 0
0 100 0
0 0
0 80 20 0
0 Sitta pusilla Brown-headed nuthatch 0
0 100 0
0 0
0 80 20 0
0 Tryngites subruficollis Buff-breasted sandpiper 0
0 100 0
0 0
0 80 20 0
0 Setophaga cerulea Cerulean warbler 0
0 100 0
0 0
0 80 20 0
0 Caprimulgus carolinensis Chuck-will's-widow 0
0 100 0
0 0
0 80 20 0
0
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 84 Table 17. Direct CCVI exposure factors for selected Tennessee CGN species Exposure to Temperature Variables Exposure to Moisture Variables Scientific Name Common Name A >5.5F A 5.1F A 4.5F A 3.9F A <3.9F
< -0.119
-0.119
-0.096
-0.073
-0.05
>-0.028 Spiza americana Dickcissel 0
0 100 0
0 0
0 80 20 0
0 Ammodramus savannarum Grasshopper sparrow 0
0 100 0
0 0
0 80 20 0
0 Ardea alba Great egret 0
0 100 0
0 0
0 80 20 0
0 Wilsonia citrina Hooded warbler 0
0 100 0
0 0
0 80 20 0
0 Limosa haemastica Hudsonian godwit 0
0 100 0
0 0
0 80 20 0
0 Oporornis formosus Kentucky warbler 0
0 100 0
0 0
0 80 20 0
0 Rallus elegans King rail 0
0 100 0
0 0
0 80 20 0
0 Chondestes grammacus Lark sparrow 0
0 100 0
0 0
0 80 20 0
0 Ixobrychus exilis Least bittern 0
0 100 0
0 0
0 80 20 0
0 Egretta caerulea Little blue heron 0
0 100 0
0 0
0 80 20 0
0 Lanius ludovicianus Loggerhead shrike 0
0 100 0
0 0
0 80 20 0
0 Seiurus motacilla Louisiana waterthrush 0
0 100 0
0 0
0 80 20 0
0 Limosa fedoa Marbled godwit 0
0 100 0
0 0
0 80 20 0
0 Ictinia mississippiensis Mississippi kite 0
0 100 0
0 0
0 100 0
0 0
Parula americana Northern parula 0
0 100 0
0 0
0 80 20 0
0 Icterus spurius Orchard oriole 0
0 100 0
0 0
0 80 20 0
0 Passerina ciris Painted bunting 0
0 100 0
0 0
0 100 0
0 0
Dendroica discolor Prairie warbler 0
0 100 0
0 0
0 80 20 0
0 Protonotaria citrea Prothonotary warbler 0
0 100 0
0 0
0 80 20 0
0 Calidris canutus Red knot 0
0 100 0
0 0
0 80 20 0
0 Melanerpes erythrocephalus Red-headed woodpecker 0
0 100 0
0 0
0 80 20 0
0 Passerculus sandwichensis Savannah sparrow 0
0 100 0
0 0
0 80 20 0
0 Tyrannus forficatus Scissor-tailed flycatcher 0
0 100 0
0 0
0 80 20 0
0 Accipiter striatus Sharp-shinned hawk 0
0 100 0
0 0
0 80 20 0
0 Calidris himantopus Stilt sandpiper 0
0 100 0
0 0
0 80 20 0
0 Limnothlypis swainsonii Swainson's warbler 0
0 100 0
0 0
0 80 20 0
0 Elanoides forficatus Swallow-tailed kite 0
0 100 0
0 0
0 80 20 0
0 Bartramia longicauda Upland sandpiper 0
0 100 0
0 0
0 80 20 0
0 Pooecetes gramineus Vesper sparrow 0
0 100 0
0 0
0 80 20 0
0 Calidris mauri Western sandpiper 0
0 100 0
0 0
0 80 20 0
0 Numenius phaeopus Whimbrel 0
0 100 0
0 0
0 80 20 0
0 Caprimulgus vociferus Whip-poor-will 0
0 100 0
0 0
0 80 20 0
0 Vireo griseus White-eyed vireo 0
0 100 0
0 0
0 80 20 0
0 Charadrius wilsonia Wilson's plover 0
0 100 0
0 0
0 80 20 0
0
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 85 Table 17. Direct CCVI exposure factors for selected Tennessee CGN species Exposure to Temperature Variables Exposure to Moisture Variables Scientific Name Common Name A >5.5F A 5.1F A 4.5F A 3.9F A <3.9F
< -0.119
-0.119
-0.096
-0.073
-0.05
>-0.028 Hylocichla mustelina Wood thrush 0
0 100 0
0 0
0 80 20 0
0 Helmitheros vermivorum Worm-eating warbler 0
0 100 0
0 0
0 80 20 0
0 Coccyzus americanus Yellow-billed cuckoo 0
0 100 0
0 0
0 80 20 0
0 Reptiles Macrochelys temminckii Alligator snapping turtle 0
0 100 0
0 0
0 100 0
0 0
Glyptemys muhlenbergii Bog turtle 0
0 100 0
0 0
0 0
100 0
0 Masticophis flagellum Coachwhip 0
0 100 0
0 0
0 100 0
0 0
Plestiodon anthracinus Coal skink 0
0 100 0
0 0
0 100 0
0 0
Terrapene carolina Eastern box turtle 0
0 100 0
0 0
0 100 0
0 0
Herterodon platirhinos Eastern hognose snake 0
0 100 0
0 0
0 100 0
0 0
Ophisaurus attenuatus longicaudus Eastern slender glass lizard 0
0 100 0
0 0
0 100 0
0 0
Anolis carolinensis Green anole 0
0 80 20 0
0 70 30 0
0 0
Clonophis kirtlandii Kirtland's snake 0
0 100 0
0 0
0 100 0
0 0
Nerodia cyclopion Mississippi green watersnake 0
0 100 0
0 0
0 100 0
0 0
Pituophis melanoleucus melanoleucus Northern pine snake 0
0 100 0
0 0
0 100 0
0 0
Virginia striatula Rough earthsnake 0
0 100 0
0 0
0 100 0
0 0
Apalone mutica Smooth softshell turtle 0
0 100 0
0 0
0 100 0
0 0
Crotalus horridus Timber rattlesnake 0
0 90 10 0
0 5
65 30 0
0 Sistrurus miliarius streckeri Western pygmy rattlesnake 0
0 100 0
0 0
0 100 0
0 0
Thamnophis proximus Western ribbonsnake 0
0 100 0
0 0
0 100 0
0 0
Nerodia erythrogaser flavigaster Yellowbelly watersnake 0
0 100 0
0 0
0 100 0
0 0
Amphibians Hyla gratiosa Barking treefrog 0
0 100 0
0 0
0 100 0
0 0
Gyrinophilus gulolineatus Berry Cave salamander 0
0 0
100 0
0 0
50 50 0
0 Desmognathus welteri Black Mountain dusky salamander 0
0 90 10 0
0 0
60 40 0
0 Lithobates areolatus Crawfish frog 0
0 90 10 0
0 0
60 40 0
0 Desmagnatus abditus Cumberland dusky salamander 0
0 90 10 0
0 0
60 40 0
0 Hemidactylium scutatum Four-toed salamander 0
0 100 0
0 0
0 100 0
0 0
Hyla versicolor Gray treefrog 0
0 100 0
0 0
0 100 0
0 0
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 86 Table 17. Direct CCVI exposure factors for selected Tennessee CGN species Exposure to Temperature Variables Exposure to Moisture Variables Scientific Name Common Name A >5.5F A 5.1F A 4.5F A 3.9F A <3.9F
< -0.119
-0.119
-0.096
-0.073
-0.05
>-0.028 Aneides aeneus Green salamander 0
0 100 0
0 0
100 0
0 0
0 Cryptobranchus alleganiensis Hellbender 0
0 100 0
0 0
95 5
0 0
0 Desmognathus imitator Imitator salamander 0
0 90 10 0
0 0
60 40 0
0 Plethodon jordani Jordan's red-cheeked salamander 0
0 90 10 0
0 0
60 40 0
0 Psedacris brachyphona Mountain chorus frog 0
0 90 10 0
0 0
60 40 0
0 Pseudtriton montanus Mud salamander 0
0 100 0
0 0
0 100 0
0 0
Plethodon montanus Northern gray-cheeked salamander 0
0 90 10 0
0 0
60 40 0
0 Desmognathus organi Northern pygmy salamander 0
0 90 10 0
0 0
60 40 0
0 Plethodon shermani Red-legged salamander 0
0 90 10 0
0 0
60 40 0
0 Desmognathus aeneus Seepage salamander 0
0 90 10 0
0 0
60 40 0
0 Acris gryllus Southern cricket frog 0
0 100 0
0 0
0 100 0
0 0
Desmognathus wrighti Southern pygmy salamander 0
0 90 10 0
0 0
60 40 0
0 Plethodon richmondi Southern ravine salamander 0
0 90 10 0
0 0
60 40 0
0 Ambystoma barbouri Streamside salamander 0
0 90 10 0
0 0
60 40 0
0 Plethodon aureolus Tellico salamander 0
0 90 10 0
0 0
60 40 0
0 Gyrinophilus palleucus Tennessee cave salamander 0
0 0
100 0
0 0
50 50 0
0 Plethodon wehrlei Wehrle's salamander 0
0 90 10 0
0 0
60 40 0
0 Plethodon welleri Weller's salamander 0
0 90 10 0
0 0
60 40 0
0 Plethodon yonahlossee Yonahlossee salamander 0
0 90 10 0
0 0
60 40 0
0 Fish Attractosteus spatula Alligator gar 0
0 100 0
0 0
0 100 0
0 0
Etheostoma sagitta Arrow darter 0
0 100 0
0 0
0 0
100 0
0 Cyprinella caerulea Blue shiner 0
0 100 0
0 0
0 0
100 0
0 Cycleptis elongatus Blue sucker 0
0 100 0
0 0
0 70 30 0
0 Salvelinus fontinalis Brook trout 0
0 100 0
0 0
0 60 20 20 0
Etheostoma cervus Chickasaw darter 0
0 100 0
0 0
0 100 0
0 0
Noturus crypticus Chucky madtom 0
0 100 0
0 0
0 0
100 0
0 Etheostoma pyrrhogaster Firebelly darter 0
0 100 0
0 0
0 100 0
0 0
Carpiodes velifer Highfin carpsucker 0
0 100 0
0 0
0 50 50 0
0 Acipenser fulvescens Lake sturgeon 0
0 100 0
0 0
0 50 50 0
0
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 87 Table 17. Direct CCVI exposure factors for selected Tennessee CGN species Exposure to Temperature Variables Exposure to Moisture Variables Scientific Name Common Name A >5.5F A 5.1F A 4.5F A 3.9F A <3.9F
< -0.119
-0.119
-0.096
-0.073
-0.05
>-0.028 Chrosomus saylori Laurel dace 0
0 100 0
0 0
0 0
100 0
0 Etheostoma bellum Orangefin darter 0
0 100 0
0 0
0 100 0
0 0
Polyodon spathula Paddlefish 0
0 100 0
0 0
0 60 40 0
0 Noturus fasciatus Saddled madtom 0
0 100 0
0 0
0 100 0
0 0
Etheostoma boschungi Slackwater darter 0
0 100 0
0 0
0 100 0
0 0
Clinostomus funduloides Smoky dace 0
0 100 0
0 0
0 60 20 20 0
Typhlichthys subterraneus Southern cavefish 0
0 100 0
0 0
0 100 0
0 0
Percina aurantiaca Tangerine darter 0
0 90 10 0
0 0
0 100 0
0 Noturus flavipinnis Yellowfin madtom 0
0 100 0
0 0
0 0
95 5
0 Mussels and Crayfish Strophitis connasaugaensis Alabama creekmussel 0
0 100 0
0 0
0 0
100 0
0 Villosa nebulosa Alabama rainbow 0
0 100 0
0 0
0 0
100 0
0 Orconectes pagei Big Sandy crayfish 0
0 100 0
0 0
0 100 0
0 0
Cambarus bouchardi Big southfork crayfish 0
0 100 0
0 0
0 0
100 0
0 Ligumia recta Black sandshell 0
0 100 0
0 0
0 25 75 0
0 Orconectes burri Blood River crayfish 0
0 100 0
0 0
0 100 0
0 0
Barbicambarus cornutus Bottlebrush crayfish 0
0 100 0
0 0
0 100 0
0 0
Strophitus undulatus Creeper 0
0 100 0
0 0
0 50 50 0
0 Medionidus conradicus Cumberland moccasinshell 0
0 100 0
0 0
0 40 60 0
0 Alasmidonta marginata Elktoe 0
0 100 0
0 0
0 10 90 0
0 Pleurobema hanleyianum Georgia pigtoe 0
0 100 0
0 0
0 0
100 0
0 Orconectes wrighti Hardin County crayfish 0
0 100 0
0 0
0 100 0
0 0
Fallicambarus hortoni Hatchie burrowing crayfish 0
0 100 0
0 0
0 100 0
0 0
Obovaria olivaria Hickorynut 0
0 100 0
0 0
0 100 0
0 0
Villosa lienosa Little spectaclecase 0
0 100 0
0 0
0 100 0
0 0
Fusconaia subrotunda Longsolid 0
0 100 0
0 0
0 60 40 0
0 Villosa vanuxemensis Mountain creekshell 0
0 100 0
0 0
0 60 40 0
0 Pleurobema cordatum Ohio pigtoe 0
0 100 0
0 0
0 50 50 0
0 Villosa taeniata Painted creekshell 0
0 100 0
0 0
0 60 40 0
0 Actinonaias pectorosa Pheasantshell 0
0 100 0
0 0
0 70 30 0
0 Toxolasma lividus Purple lilliput 0
0 100 0
0 0
0 70 30 0
0 Pleurobema rubrum Pyramid pigtoe 0
0 100 0
0 0
0 40 60 0
0 Quadrula cylindrica Rabbitsfoot 0
0 100 0
0 0
0 25 75 0
0 Obovaria subrotunda Round hickorynut 0
0 100 0
0 0
0 60 40 0
0 Pleurobema sintoxia Round pigtoe 0
0 100 0
0 0
0 50 50 0
0
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 88 Table 17. Direct CCVI exposure factors for selected Tennessee CGN species Exposure to Temperature Variables Exposure to Moisture Variables Scientific Name Common Name A >5.5F A 5.1F A 4.5F A 3.9F A <3.9F
< -0.119
-0.119
-0.096
-0.073
-0.05
>-0.028 Pleuronaia dolabelloides Slabside pearlymussel 0
0 100 0
0 0
0 25 75 0
0 Alasmidonta viridis Slippershell mussel 0
0 100 0
0 0
0 40 60 0
0 Villosa vibex Southern rainbow 0
0 100 0
0 0
0 95 5
0 0
Cumberlandia monodonta Spectaclecase 0
0 100 0
0 0
0 100 0
0 0
Orconectes alabamensis Stateline crayfish 0
0 100 0
0 0
0 100 0
0 0
Orconectes incomptus Tennessee cave crayfish 0
0 100 0
0 0
0 100 0
0 0
Pleurobema oviforme Tennessee clubshell 0
0 100 0
0 0
0 50 50 0
0 Lasmigona holstonia Tennessee heelsplitter 0
0 100 0
0 0
0 0
100 0
0 Pleuronaia barnesiana Tennessee pigtoe 0
0 100 0
0 0
0 40 60 0
0 Lasmigona complanata White heelsplitter 0
0 100 0
0 0
0 50 50 0
0 Plants Hottonia inflata American featherfoil 0
0 100 0
0 0
0 0
100 0
0 Asplenium scolopendrium var. americanum (syn.
Phyllitis scolopendrium var.
americana)
American hart's-tongue 0
0 100 0
0 0
0 0
0 100 0
Solidago spithamaea Blue Ridge goldenrod 0
0 100 0
0 0
0 71 29 0
0 Boechera perstellata (syn.
Arabis perstellata)
Braun's rockcress 0
0 100 0
0 0
0 100 0
0 0
Conradina verticillata Cumberland rosemary 0
0 100 0
0 0
0 7
86 7
0 Minuartia cumberlandensis (syn. Arenaria cumberlandensis)
Cumberland sandwort/
Cumberland stitchwort 0
0 100 0
0 0
0 86 14 0
0 Helianthus eggertii Eggert's sunflower 0
0 100 0
0 0
0 0
100 0
0 Panax quinquefolius Ginseng 0
0 100 0
0 0
0 25 75 0
0 Scutellaria montana Large-flowered skullcap 0
0 100 0
0 0
0 88 12 0
0 Dalea foliosa Leafy prairie-clover 0
0 100 0
0 0
0 100 0
0 0
Clematis morefieldii Morefield's leatherflower 0
0 100 0
0 0
0 0
0 100 0
Buckleya distichophylla Pirate bush 0
0 100 0
0 0
0 0
100 0
0 Apios priceana Price's potato bean 0
0 100 0
0 0
0 100 0
0 0
Astragalus bibullatus Pyne's ground-plum 0
0 100 0
0 0
0 0
0 100 0
Hedyotis purpurea var.
montana (syn. Houstonia montana)
Roan Mountain bluet/Venus' pride 0
0 100 0
0 0
0 100 0
0 0
Gymnoderma lineare Rock gnome lichen 0
0 100 0
0 0
0 0
0 100 0
Pityopsis ruthii Ruth's golden aster 0
0 100 0
0 0
0 100 0
0 0
Physaria globosa (syn.
Lesquerella globosa)
Short's bladderpod 0
0 100 0
0 0
0 86 14 0
0
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 89 Table 17. Direct CCVI exposure factors for selected Tennessee CGN species Exposure to Temperature Variables Exposure to Moisture Variables Scientific Name Common Name A >5.5F A 5.1F A 4.5F A 3.9F A <3.9F
< -0.119
-0.119
-0.096
-0.073
-0.05
>-0.028 Isotria medeoloides Small whorled pogonia/little five leaves 0
0 100 0
0 0
0 46 48 6
0 Geum radiatum Spreading avens/
Appalachian avens 0
0 100 0
0 0
0 100 0
0 0
Paysonia perforata (syn.
Lesquerella perforata)
Spring Creek bladderpod 0
0 100 0
0 0
0 100 0
0 0
Echinacea tennesseensis Tennessee purple coneflower 0
0 100 0
0 0
0 0
100 0
0 Xyris tennesseensis Tennessee yellow-eyed grass 0
0 100 0
0 0
0 100 0
0 0
Spiraea virginiana Virginia spiraea/
Virginia meadowsweet 0
0 100 0
0 0
0 13 87 0
0 Platanthera integrilabia White fringeless orchid/monkey-face orchid 0
0 100 0
0 0
0 29 71 0
0 Helianthus verticillatus Whorled sunflower 0
0 100 0
0 0
0 100 0
0 0
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 90 APPENDIX C. INDIRECT EXPOSURE AND SENSITIVITY FACTORS FOR SELECTED TENNESSEE SPECIES Tables 18-24 identify the findings for individual risk factors (i.e., indirect exposure and sensitivity) for the various Tennessee GCN species included in this assessment, as determined by the assessment team experts. None of the teams included Documented or Modeled Response to Climate Change in their analyses, so those categories are omitted here. The tables here are sorted by the species common name to facilitate identification of findings for particular species of interest. The codes in these tables are defined as follows:
Individual Risk Factors GI = Greatly Increase Vulnerability Inc = Increase Vulnerability SI = Somewhat Increase Vulnerability N = Neutral SD = Somewhat Decrease Vulnerability Dec = Decrease Vulnerability U = Unknown NA = Not Applicable CCVI Index Score EV = Extremely Vulnerable HV = Highly Vulnerable MV = Moderately Vulnerable PS = Presumed Stable IL = Increase Likely IE = Insufficient Evidence
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 91 Table 18. Indirect exposure and sensitivity factors for selected Tennessee mammals Scientific Name Common Name Indirect Exposure Factors Sensitivity Factors Sea-level rise Natural barriers Anthropogenic barriers Human response to climate Dispersal and movements Historical thermal niche Physiological thermal niche Historical hydrological niche Physiological hydro niche Dependence on disturbance Dependence on ice, snow Restricted habitat features Depend on spp for habitat Dietary versatility (animals)
Pollinator versatility (plants)
Propagule dispersal Other interspecific interaction Measured genetic variation Evolutionary Bottlenecks Phenological response Index Score Neotoma magister Allegheny woodrat N
N N
U S
D N
N N
N N
N S
I N
N N
A N
N U
U U
P S
Sorex palustris American water shrew N
S I
N U
N S
I S
I N
S I
N N
N N
N N
A N
N U
U U
M V
Glaucomys sabrinus coloratus Carolina northern flying squirrel N
G I
S I
U S
D S
I G
I N
N S
I N
S D
N S
D N
A N
S I
U U
U H
V Myotis leibii Eastern small-footed bat N
N N
U S
D N
N N
N N
N S
I N
N N
A N
N U
U U
P S
Myotis grisescens Gray bat N
N N
U S
D N
N N
N N
N I
n c
N N
N A
N N
U U
U P
S Parascalops breweri Hairy-tailed mole N
S I
N U
N N
N N
N N
N N
N N
N A
N N
U U
U P
S Myotis sodalis Indiana bat N
N N
U D
e c
N N
N N
N N
I n
c N
N N
A N
N U
U U
P S
Mustela nivalis Least weasel N
N N
U N
N N
N N
S D
N U
N N
N A
N N
U U
U P
S Myotis septentrionalis Northern myotis N
N N
U D
e c
N N
N N
N N
S I
N N
N A
N N
U U
U P
S Corynorhinus rafinesquii Rafinesque's big-eared bat N
N N
U S
D N
N N
N S
I N
N N
N N
A N
N U
U U
P S
Tamiasciurus hudsonicus Red squirrel N
N U
U N
S I
S I
N N
N N
S D
N N
N A
N N
U U
U P
S Sorex fumeus Smoky shrew N
S I
N U
S I
N N
N S
I N
N N
N N
N A
N N
U U
U P
S Microtus chrotorrhinus carolinensis Southern rock vole N
I n
c N
U N
S I
G I
N N
S D
N S
I N
N N
A N
N U
U U
M V
Condylura cristata Star-nosed mole N
S I
N U
N N
N N
N N
N S
I N
N N
A N
N U
U U
P S
Napaeozapus insignis Woodland jumping mouse N
N N
U N
N S
I N
S I
N N
N N
N N
A N
N U
U U
P S
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 92 Table 19. Indirect exposure and sensitivity factors for selected Tennessee birds Scientific Name Common Name Indirect Exposure Factors Sensitivity Factors Sea-level rise Natural barriers Anthropogenic barriers Human response to climate Dispersal and movements Historical thermal niche Physiological thermal niche Historical hydrological niche Physiological hydro niche Dependence on disturbance Dependence on ice, snow Restricted habitat features Depend on spp for habitat Dietary versatility (animals)
Pollinator versatility (plants)
Propagule dispersal Other interspecific Measured genetic variation Evolutionary Bottlenecks Phenological response Index Score Botaurus lentiginosus American bittern N
N N
N S
D N
N N
N N
N S
I N
N N
A N
N U
U U
P S
Pluvialis dominica American golden plover N
N N
N S
D N
N N
N N
I n
c S
I N
S I
N A
N N
U U
U P
S Scolopax minor American woodcock N
N N
S I
N S
I N
N N
N I
n c
N S
I N
S I
N A
N U
U U
U M
V Anhinga anhinga Anhinga N
N N
N D
e c
N N
N N
N N
S I
N S
I N
A N
U U
U S
I P
S Aimophila aestivalis Bachman's sparrow N
N N
N S
I N
N N
N I
n c
N I
n c
S I
N N
N A
N U
U U
U M
V Riparia riparia Bank swallow N
N N
N S
I N
N N
N N
N S
I N
S I
N A
N U
U U
U P
S Tyto alba Barn owl S
D N
N N
D e
c N
N N
N N
N N
N N
N A
U U
U U
N I
L Vireo bellii Bell's vireo N
N N
N D
e c
N N
N N
N N
S I
N S
I N
A U
U U
U S
I P
S Thryomanes bewickii Bewick's wren N
N N
N D
e c
N N
N N
N N
N N
I n
c N
A U
U U
U S
I P
S Vermiforma pinus Blue-winged warbler N
N N
N D
e c
N N
N N
N N
S I
N S
I N
A U
U U
U S
I P
S Sitta pusilla Brown-headed nuthatch N
N N
S I
N D
e c
N N
N N
I n
c N
S I
N N
N A
U U
U U
S I
P S
Tryngites subruficollis Buff-breasted sandpiper N
N N
N S
D N
N N
N N
S I
S I
N S
I N
A U
U U
U S
I P
S Setophaga cerulea Cerulean warbler N
N N
N D
e c
N N
N N
N N
I n
c N
S I
N A
U U
U U
I n
c P
S Caprimulgus carolinensis Chuck-will's-widow N
N N
N D
e c
N N
N N
N N
S I
N S
I N
A U
U U
U S
I P
S Spiza americana Dickcissel N
N N
N D
e c
N N
N N
N N
N N
S D
N A
U U
U U
S I
I L
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 93 Table 19. Indirect exposure and sensitivity factors for selected Tennessee birds Scientific Name Common Name Indirect Exposure Factors Sensitivity Factors Sea-level rise Natural barriers Anthropogenic barriers Human response to climate Dispersal and movements Historical thermal niche Physiological thermal niche Historical hydrological niche Physiological hydro niche Dependence on disturbance Dependence on ice, snow Restricted habitat features Depend on spp for habitat Dietary versatility (animals)
Pollinator versatility (plants)
Propagule dispersal Other interspecific Measured genetic variation Evolutionary Bottlenecks Phenological response Index Score Ammodramus savannarum Grasshopper sparrow N
N N
N D
e c
N N
N N
S I
N N
S I
N N
N A
U U
U U
S I
P S
Ardea alba Great egret N
N N
N D
e c
N N
N N
N N
N N
S D
N A
U U
U U
S I
I L
Wilsonia citrina Hooded warbler N
N N
N D
e c
N N
N N
N N
N N
N N
A U
U U
U S
I P
S Limosa haemastica Hudsonian godwit N
N N
N D
e c
N N
N N
N N
N N
S D
N A
U U
U U
S I
I L
Oporornis formosus Kentucky warbler N
N N
N D
e c
N N
N N
N N
N N
S I
N A
U U
U U
S I
P S
Rallus elegans King rail N
N N
N D
e c
N N
N N
N N
S I
N N
N A
U U
U U
S I
P S
Chondestes grammacus Lark sparrow N
N N
N D
e c
N N
N N
S I
N S
I N
N N
A U
U U
U S
I P
S Ixobrychus exilis Least bittern N
N N
N D
e c
N N
N N
N N
I n
c N
S D
N A
U U
U U
S I
P S
Egretta caerulea Little blue heron S
I N
N N
D e
c N
N N
N N
N S
I N
S D
N A
U U
U U
S I
P S
Lanius ludovicianus Loggerhead shrike N
N N
N D
e c
N N
N N
N N
S I
N N
N A
U U
U U
S I
P S
Seiurus motacilla Louisiana waterthrush N
N N
N D
e c
N N
N N
N N
N N
S D
N A
U U
U U
S I
I L
Limosa fedoa Marbled godwit N
N N
N D
e c
N N
N N
N N
S I
N N
N A
U U
U U
S I
P S
Ictinia mississippiensis Mississippi kite N
N N
S D
D e
c N
N N
N N
N N
N S
D N
A U
U U
U S
I I
L Parula americana Northern parula N
N N
N D
e c
N N
N N
N N
S I
N S
I N
A U
U U
U S
I P
S Icterus spurius Orchard oriole N
N N
N D
e c
N N
N N
N N
N N
S D
N A
U U
U U
S I
I L
Passerina ciris Painted bunting N
N N
N D
e c
N N
N N
N N
N N
S D
N A
U U
U U
S I
I L
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 94 Table 19. Indirect exposure and sensitivity factors for selected Tennessee birds Scientific Name Common Name Indirect Exposure Factors Sensitivity Factors Sea-level rise Natural barriers Anthropogenic barriers Human response to climate Dispersal and movements Historical thermal niche Physiological thermal niche Historical hydrological niche Physiological hydro niche Dependence on disturbance Dependence on ice, snow Restricted habitat features Depend on spp for habitat Dietary versatility (animals)
Pollinator versatility (plants)
Propagule dispersal Other interspecific Measured genetic variation Evolutionary Bottlenecks Phenological response Index Score Dendroica discolor Prairie warbler N
N N
N D
e c
N N
N N
S I
N S
I N
S I
N A
U U
U U
S I
P S
Protonotaria citrea Prothonotary warbler N
N N
N D
e c
N N
N N
N N
S I
S I
S I
N A
U U
U U
S I
P S
Calidris canutus Red knot S
I N
N N
D e
c N
N N
N N
N S
I N
I n
c N
A U
U U
U S
I P
S Melanerpes erythrocephalus Red-headed woodpecker N
N N
N D
e c
N N
N N
N N
S I
N N
N A
U U
U U
S I
P S
Passerculus sandwichensis Savannah sparrow N
N N
N D
e c
N N
N N
N N
N N
S D
N A
U U
U U
S I
I L
Tyrannus forficatus Scissor-tailed flycatcher N
N N
N D
e c
N N
N N
N N
N N
S I
N A
U U
U U
S I
P S
Accipiter striatus Sharp-shinned hawk N
N N
N D
e c
N N
N N
N N
S I
N N
N N
A U
U U
U S
I P
S Calidris himantopus Stilt sandpiper N
N N
N D
e c
N N
N N
N S
I S
I N
N N
A U
U U
U S
I P
S Limnothlypis swainsonii Swainson's warbler N
N N
N D
e c
N N
N N
N N
S I
N S
I N
A U
U U
U S
I P
S Elanoides forficatus Swallow-tailed kite N
N N
N D
e c
N N
N N
N N
S I
N N
N A
U U
U U
S I
P S
Bartramia longicauda Upland sandpiper N
N N
N D
e c
N N
N N
U N
I n
c N
S I
N A
U U
U U
S I
P S
Pooecetes gramineus Vesper sparrow N
N N
N D
e c
N N
N N
N N
S I
N S
D N
A U
U U
U S
I P
S Calidris mauri Western sandpiper N
N N
N D
e c
N N
N N
N N
S I
N S
I N
A U
U U
U S
I P
S Numenius phaeopus Whimbrel N
N N
N D
e c
N N
N N
N N
S I
N S
D N
A U
U U
U S
I P
S Caprimulgus vociferus Whip-poor-will N
N N
N D
e c
N N
N N
N N
S I
N S
I N
A U
U U
U S
I P
S Vireo griseus White-eyed vireo N
N N
N D
e c
N N
N N
S I
N N
N S
D N
A U
U U
U S
I P
S
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 95 Table 19. Indirect exposure and sensitivity factors for selected Tennessee birds Scientific Name Common Name Indirect Exposure Factors Sensitivity Factors Sea-level rise Natural barriers Anthropogenic barriers Human response to climate Dispersal and movements Historical thermal niche Physiological thermal niche Historical hydrological niche Physiological hydro niche Dependence on disturbance Dependence on ice, snow Restricted habitat features Depend on spp for habitat Dietary versatility (animals)
Pollinator versatility (plants)
Propagule dispersal Other interspecific Measured genetic variation Evolutionary Bottlenecks Phenological response Index Score Charadrius wilsonia Wilson's plover I
n c
N N
N D
e c
N N
N N
N N
S I
N S
I N
A U
U U
U S
I P
S Hylocichla mustelina Wood thrush N
N N
N D
e c
N N
N N
N N
S I
N S
D N
A U
U U
U S
I P
S Helmitheros vermivorum Worm-eating warbler N
N N
N D
e c
N N
N N
N N
I n
c N
S I
N A
U U
U U
S I
P S
Coccyzus americanus Yellow-billed cuckoo N
N N
N D
e c
N N
N N
N N
S I
N S
I N
A U
U U
U S
I P
S
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 96 Table 20. Indirect exposure and sensitivity factors for selected Tennessee reptiles Scientific Name Common Name Indirect Exposure Factors Sensitivity Factors Sea-level rise Natural barriers Anthropogenic barriers Human response to climate Dispersal and movements Historical thermal niche Physiological thermal niche Historical hydrological niche Physiological hydro niche Dependence on disturbance Dependence on ice, snow Restricted habitat features Depend on spp for habitat Dietary versatility (animals)
Pollinator versatility (plants)
Propagule dispersal Other interspecific interaction Measured genetic variation Evolutionary Bottlenecks Phenological response Index Score Macrochelys temminckii Alligator snapping turtle N
N N
N S
D N
N S
D N
N N
N N
N N
A N
N U
U U
I L
Glyptemys muhlenbergii Bog turtle U
S I
S I
N N
N N
N N
N U
I n
c S
I S
D N
A N
U S
I U
U M
V Masticophis flagellum Coachwhip U
N N
N N
N S
D N
N N
U S
D N
N N
A N
U U
U U
I L
Plestiodon anthracinus Coal skink N
N N
N I
n c
N N
S D
S I
N N
N N
N N
A N
N U
U U
P S
Terrapene carolina Eastern box turtle N
N I
n c
N S
I N
N S
D N
N N
N N
N N
A N
N U
U U
P S
Herterodon platirhinos Eastern hognose snake N
N I
n c
N I
n c
N N
S D
N N
N N
N N
N A
N N
U U
U P
S Ophisaurus attenuatus longicaudus Eastern slender glass lizard N
N S
I N
S I
N N
S D
N N
N N
N N
N A
N N
U U
U P
S Anolis carolinensis Green anole U
N N
N N
N S
D N
N N
U S
D N
N N
A N
U U
U U
I L
Clonophis kirtlandii Kirtland's snake U
N N
N S
I N
N N
N N
U N
S I
S I
N A
N U
U U
U P
S Nerodia cyclopion Mississippi green watersnake N
N N
N I
n c
N N
S D
I n
c N
N N
N N
N A
N N
U U
U P
S Pituophis melanoleucus melanoleucus Northern pine snake N
N S
I N
N N
N S
D N
N N
N N
N N
A N
N U
U U
P S
Virginia striatula Rough earthsnake N
N N
N N
N N
S D
N N
N N
N N
N A
N N
U U
U P
S Apalone mutica Smooth softshell turtle N
N N
N N
N N
S D
N N
N N
N N
N A
N N
U U
U P
S Crotalus horridus Timber rattlesnake N
N S
I N
N N
N S
D N
N N
N N
N N
A N
N U
U U
P S
Sistrurus miliarius streckeri Western pygmy rattlesnake N
N S
I N
N N
N S
D N
N N
N N
N N
A N
N U
U U
P S
Thamnophis proximus Western ribbonsnake U
N N
N N
N N
N N
N U
N N
N N
A N
U U
U U
P S
Nerodia erythrogaser flavigaster Yellowbelly watersnake N
N N
N N
N N
S D
N N
N N
N N
N A
N N
U U
U P
S
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 97 Table 21. Indirect exposure and sensitivity factors for selected Tennessee amphibians Scientific Name Common Name Indirect Exposure Factors Sensitivity Factors Sea-level rise Natural barriers Anthropogenic barriers Human response to climate Dispersal and movements Historical thermal niche Physiological thermal niche Historical hydrological niche Physiological hydro niche Dependence on disturbance Dependence on ice, snow Restricted habitat features Depend on spp for habitat Dietary versatility (animals)
Pollinator versatility (plants)
Propagule dispersal Other interspecific Measured genetic variation Evolutionary Bottlenecks Phenological response Index Score Hyla gratiosa Barking treefrog N
N S
I N
N N
N S
D G
I N
N S
I N
N N
A N
N U
U U
M V
Gyrinophilus gulolineatus Berry Cave salamander N
S I
N U
S I
S I
S I
S D
N N
N I
n c
N N
N A
N N
U U
U M
V Desmognathus welteri Black Mountain dusky salamander N
I n
c N
N S
I N
N S
D S
I N
N N
N N
N A
N U
U U
U P
S Lithobates areolatus Crawfish frog N
N S
I U
S I
N N
N S
I N
N N
S I
N N
A N
N U
U U
M V
Desmognathus abditus Cumberland dusky salamander N
N S
I N
S I
N N
S D
S I
N N
N N
N N
A N
N U
U U
P S
Hemidactylium scutatum Four-toed salamander N
N S
I U
S I
N N
S D
G I
N N
S I
N N
N A
U N
U U
U M
V Hyla versicolor Gray treefrog N
N N
U S
I N
N N
G I
N N
N N
N N
A N
N U
U U
M V
Aneides aeneus Green salamander N
S I
S I
U S
I N
S I
S D
N N
N S
I N
N N
A U
U U
U U
M V
Cryptobranchus alleganensis Hellbender N
N I
n c
N N
N I
n c
S D
S I
N U
S I
N S
I N
A N
N U
U U
H V
Desmognathus imitator Imitator salamander N
N N
N S
I S
I S
I S
D S
I N
N N
N N
N A
N U
U U
U P
S Plethodon jordani Jordan's red-cheeked salamander N
N N
N S
I S
I S
I S
D N
N N
N N
N N
A N
U U
U U
P S
Pseudacris brachyphona Mountain chorus frog N
N S
I N
N N
N S
D G
I N
N S
I N
N N
A N
N U
U U
M V
Pseudotriton montanus Mud salamander N
N S
I U
S I
N N
S D
S I
N N
S I
N N
N A
N N
U U
U P
S Plethodon montanus Northern gray-cheeked salamander N
N N
N S
I S
I S
I S
D N
N N
N N
N N
A N
U U
U U
P S
Desmognathus organi Northern pygmy salamander N
N N
N S
I S
I S
I S
D N
N N
N N
N N
A N
U U
U U
P S
Plethodon shermani Red-legged salamander N
N N
N S
I S
I S
I S
D N
N N
N N
N N
A N
U U
U U
P S
Desmognathus aeneus Seepage salamander N
N S
I N
S I
N N
S D
G I
N N
S I
N N
N A
N N
U U
U M
V Acris gryllus Southern cricket frog N
N S
I U
S I
N N
S D
G I
N N
N N
N N
A N
N U
U U
M V
Desmognathus wrighti Southern pygmy salamander N
I n
c N
U S
I S
I S
I S
D N
N N
N N
N N
A N
U U
U U
P S
Plethodon richmondi Southern ravine salamander N
N N
N S
I S
I N
S D
N N
N S
I N
N N
A N
N U
U U
P S
Ambystoma barbouri Streamside salamander N
N S
I N
S I
N N
S D
I n
c N
N N
N N
N A
N U
U U
U P
S
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 98 Table 21. Indirect exposure and sensitivity factors for selected Tennessee amphibians Scientific Name Common Name Indirect Exposure Factors Sensitivity Factors Sea-level rise Natural barriers Anthropogenic barriers Human response to climate Dispersal and movements Historical thermal niche Physiological thermal niche Historical hydrological niche Physiological hydro niche Dependence on disturbance Dependence on ice, snow Restricted habitat features Depend on spp for habitat Dietary versatility (animals)
Pollinator versatility (plants)
Propagule dispersal Other interspecific Measured genetic variation Evolutionary Bottlenecks Phenological response Index Score Plethodon aureolus Tellico salamander N
N N
N S
I S
I N
S D
N N
N N
N N
N A
N N
U U
U P
S Gyrinophilus palleucus Tennessee cave salamander N
S I
N U
S I
S I
S I
S D
N N
N I
n c
N N
N A
N N
U U
U M
V Plethodon wehrlei Wehrle's salamander N
N N
N S
I N
N N
N N
N N
N N
N A
N N
U U
U P
S Plethodon welleri Weller's salamander N
N N
N S
I S
I S
I S
D N
N N
S I
N N
N A
N U
U U
U P
S Plethodon yonahlossee Yonahlossee salamander N
N N
N S
I S
I N
S D
N N
N S
I N
N N
A N
N U
U U
P S
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 99 Table 22. Indirect exposure and sensitivity factors for selected Tennessee fish Scientific Name Common Name Indirect Exposure Factors Sensitivity Factors Sea-level rise Natural barriers Anthropogenic barriers Human response to climate Dispersal and movements Historical thermal niche Physiological thermal niche Historical hydrological niche Physiological hydro niche Dependence on disturbance Dependence on ice, snow Restricted habitat features Depend on spp for habitat Dietary versatility (animals)
Pollinator versatility (plants)
Propagule dispersal Other interspecific interaction Measured genetic variation Evolutionary Bottlenecks Phenological response Index Score Attractosteus spatula Alligator gar N
N I
n c
I n
c N
N N
N S
I S
I N
N N
N N
A N
N U
U S
I H
V Etheostoma sagitta Arrow darter N
N I
n c
I n
c S
I N
N N
I n
c S
I N
N N
N N
N A
N I
n c
U U
U H
V Cyprinella caerulea Blue shiner N
N N
N N
N N
N I
n c
N N
N N
N N
A N
N U
U U
P S
Cycleptis elongatus Blue sucker N
N I
n c
S I
N N
N N
I n
c S
I N
N N
N N
N A
N N
U U
S I
M V
Salvelinus fontinalis Brook trout N
I n
c N
N N
N G
I I
n c
N I
n c
S I
N N
I n
c S
I N
N N
A N
S I
U S
I U
E V
Etheostoma cervus Chickasaw darter N
N N
S I
N N
N N
S I
N N
N N
N N
A N
N U
U U
P S
Noturus crypticus Chucky madtom S
I N
I n
c I
n c
N N
S I
N S
I N
N N
N N
N A
N N
U U
U H
V Etheostoma pyrrhogaster Firebelly darter N
N N
I n
c N
N N
N S
I N
N N
N N
N A
N N
U U
N P
S Carpiodes velifer Highfin carpsucker N
N I
n c
S I
N N
N N
I n
c S
I N
N N
N N
N A
N N
U U
S I
M V
Acipenser fulvescens Lake sturgeon N
N G
I I
n c
S I
N N
I n
c S
I N
I n
c N
N N
N N
N A
N N
N N
A I
n c
E V
Chrosomus saylori Laurel dace N
N S
I U
N N
S I
N I
n c
S I
N N
S I
N N
N N
A N
N U
U U
M V
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 100 Table 22. Indirect exposure and sensitivity factors for selected Tennessee fish Scientific Name Common Name Indirect Exposure Factors Sensitivity Factors Sea-level rise Natural barriers Anthropogenic barriers Human response to climate Dispersal and movements Historical thermal niche Physiological thermal niche Historical hydrological niche Physiological hydro niche Dependence on disturbance Dependence on ice, snow Restricted habitat features Depend on spp for habitat Dietary versatility (animals)
Pollinator versatility (plants)
Propagule dispersal Other interspecific interaction Measured genetic variation Evolutionary Bottlenecks Phenological response Index Score Etheostoma bellum Orangefin darter N
N S
I N
N N
N N
I n
c N
N N
N N
N A
N N
U U
S I
M V
Polyodon spathula Paddlefish N
N G
I I
n c
I n
c S
I N
N N
N S
I N
N N
N S
I N
N A
N S
I U
U U
H V
Noturus fasciatus Saddled madtom N
N N
I n
c N
N N
N I
n c
N N
N N
N N
A N
N U
U U
M V
Etheostoma boschungi Slackwater darter N
N I
n c
I n
c N
N N
N I
n c
N N
N N
N N
A N
N U
U I
n c
E V
Clinostomus funduloides Smoky dace N
S I
S I
N N
N S
I N
S I
N N
N S
I N
N N
A N
N U
U N
M V
Typhlichthys subterraneus Southern cavefish N
S I
N N
I n
c N
N N
N S
I N
N S
I N
N N
A N
N U
U U
P S
Percina aurantiaca Tangerine darter N
N I
n c
I n
c N
N N
N S
I N
N N
N N
N A
N N
U U
U M
V Noturus flavipinnis Yellowfin madtom N
N N
I n
c N
N S
I N
N N
N N
N N
N A
N N
U U
U P
S
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 101 Table 23. Indirect exposure and sensitivity factors for selected Tennessee mussels and crayfish Scientific Name Common Name Indirect Exposure Factors Sensitivity Factors Sea-level rise Natural barriers Anthropogenic barriers Human response to climate Dispersal and movements Historical thermal niche Physiological thermal niche Historical hydrological niche Physiological hydro niche Dependence on disturbance Dependence on ice, snow Restricted habitat features Depend on spp for habitat Dietary versatility (animals)
Pollinator versatility (plants)
Propagule dispersal Other interspecific interaction Measured genetic variation Evolutionary Bottlenecks Phenological response Index Score Strophitis connasaugaensis Alabama creekmussel N
N I
n c
S I
I n
c N
N N
N N
N N
N N
N A
S I
U U
U N
M V
Villosa nebulosa Alabama rainbow N
N I
n c
S I
I n
c N
N N
N N
N N
N N
N A
S I
U U
U N
M V
Orconectes pagei Big Sandy crayfish U
N N
N N
N N
N N
N N
N N
N N
A N
N U
U U
P S
Cambarus bouchardi Big southfork crayfish N
N N
I n
c N
N N
N N
N N
N N
N N
A N
N U
U U
P S
Ligumia recta Black sandshell N
N I
n c
S I
N N
N N
N N
N N
N N
N A
N U
U U
U P
S Orconectes burri Blood River crayfish N
N I
n c
S I
N N
N N
N N
N N
N N
N A
N N
U U
U P
S Barbicambarus cornutus Bottlebrush crayfish N
N S
I S
I N
N N
N N
N N
S I
N N
N A
N N
U U
U P
S Strophitus undulates Creeper N
N S
I U
N N
N N
N N
N N
N N
N A
N U
U U
U P
S Medionidus conradicus Cumberland moccasinshell N
N I
n c
S I
I n
c N
N N
N N
N N
N N
N A
S I
U U
U N
M V
Alasmidonta marginata Elktoe N
N I
n c
S I
I n
c N
N N
N N
N N
N N
N A
S I
U U
U N
M V
Pleurobema hanleyianum Georgia pigtoe N
N I
n c
S I
I n
c N
N N
N N
N N
N N
N A
S I
U U
U N
M V
Orconectes wright Hardin County crayfish N
N N
U N
N S
I S
D S
I N
N N
N N
N A
N N
U U
U P
S Fallicambarus hortoni Hatchie burrowing crayfish N
N N
S I
N N
S D
N S
I N
N N
N N
N A
N U
U U
U P
S Obovaria olivaria Hickorynut N
N N
I n
c N
N N
N N
N N
N N
N N
A I
n c
N U
U U
M V
Villosa lienosa Little spectaclecase N
N S
I U
U N
N N
I n
c N
N N
N N
N A
S I
N U
U U
M V
Fusconaia subrotunda Longsolid N
N I
n c
S I
I n
c N
N N
N N
N N
N N
N A
S I
U U
U N
H V
Villosa vanuxemensis Mountain creekshell N
N I
n c
S I
I n
c N
N N
N N
N N
N N
N A
S I
U U
U N
H V
Pleurobema cordatum Ohio pigtoe N
N I
n c
U S
I N
N N
N N
N N
N N
N A
S I
U U
U U
M V
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 102 Table 23. Indirect exposure and sensitivity factors for selected Tennessee mussels and crayfish Scientific Name Common Name Indirect Exposure Factors Sensitivity Factors Sea-level rise Natural barriers Anthropogenic barriers Human response to climate Dispersal and movements Historical thermal niche Physiological thermal niche Historical hydrological niche Physiological hydro niche Dependence on disturbance Dependence on ice, snow Restricted habitat features Depend on spp for habitat Dietary versatility (animals)
Pollinator versatility (plants)
Propagule dispersal Other interspecific interaction Measured genetic variation Evolutionary Bottlenecks Phenological response Index Score Villosa taeniata Painted creekshell N
N I
n c
S I
I n
c N
N N
N N
N N
N N
N A
S I
U U
U N
H V
Actinonaias pectorosa Pheasantshell N
N S
I S
I I
n c
N N
N N
N N
N N
N N
A S
I N
U U
N M
V Toxolasma lividus Purple lilliput N
N I
n c
S I
I n
c N
N N
N N
N N
N N
N A
S I
U U
U N
H V
Pleurobema rubrum Pyramid pigtoe N
N I
n c
N S
I N
N N
N N
N N
N N
N A
I n
c N
U U
U M
V Quadrula cylindrical Rabbitsfoot N
N I
n c
S I
S I
N N
N N
N N
N N
N N
A S
I U
U U
U M
V Obovaria subrotunda Round hickorynut N
N I
n c
S I
I n
c N
N N
N N
N N
N N
N A
S I
U U
U N
H V
Pleurobema sintoxia Round pigtoe N
N I
n c
N N
N N
N N
N N
N N
N N
A N
U U
U U
P S
Pleuronaia dolabelloides Slabside pearlymussel N
N I
n c
S I
I n
c N
N N
N N
N N
N N
N A
N U
U U
U M
V Alasmidonta viridis Slippershell mussel N
N I
n c
S I
I n
c N
N N
N N
N N
N N
N A
S I
U U
U N
M V
Villosa vibex Southern rainbow N
N N
I n
c N
N N
N S
I N
N N
N N
N A
N N
U U
U P
S Cumberlandia monodonta Spectaclecase N
N S
I S
I I
n c
N N
N N
N N
N N
N N
A S
I U
U U
U M
V Orcontectes alabamensis Stateline crayfish N
N N
U N
N N
N S
I N
N N
N N
N A
N U
U U
U p
s Pleurobema oviforme Tennessee clubshell N
N I
n c
S I
I n
c N
N N
N N
N N
N N
N A
S I
U U
U N
H V
Lasmigona holstonia Tennessee heelsplitter N
N I
n c
S I
I n
c N
N N
N N
N N
N N
N A
S I
U U
U N
M V
Pleuronaia barnesiana Tennessee pigtoe N
N I
n c
S I
I n
c N
N N
N N
N N
N N
N A
S I
U U
U N
M V
Lasmigona complanata White heelsplitter N
N S
I U
N N
N N
N N
N N
N N
N A
N U
U U
U P
S
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 103 Table 24. Indirect exposure and sensitivity factors for selected Tennessee plants Scientific Name Common Name Indirect Exposure Factors Sensitivity Factors Sea-level rise Natural barriers Anthropogenic barriers Human response to climate Dispersal and movements Historical thermal niche Physiological thermal niche Historical hydrological niche Physiological hydro niche Dependence on disturbance Dependence on ice, snow Restricted habitat features Depend on spp for habitat Dietary versatility (animals)
Pollinator versatility (plants)
Propagule dispersal Other interspecific interaction Measured genetic variation Evolutionary Bottlenecks Phenological response Index Score Hottonia inflata American featherfoil N
N N
U D
e c
S D
N I
n c
N N
N N
N N
A N
N N
U U
U P
S Asplenium scolopendrium var. americanum (syn. Phyllitis scolopendrium var. americana)
American hart's-tongue N
G I
N U
S I
N G
I G
I N
N N
I n
c N
N A
U N
N U
I n
c U
E V
Solidago spithamaea Blue Ridge goldenrod N
G I
N U
N S
I G
I G
I N
N N
N N
N A
N N
U U
U U
H V
Boechera perstellata (syn.
Arabis perstellata)
Braun's rockcress N
S I
S I
N I
n c
N N
I n
c N
N N
N N
N A
N N
N S
I N
A U
H V
Conradina verticillata Cumberland Rosemary N
G I
N U
S I
N N
I n
c N
N N
N N
N A
N N
N S
D N
A U
M V
Minuartia cumberlandensis (syn. Arenaria cumberlandensis)
Cumberland sandwort/
Cumberland stitchwort N
I n
c N
U S
I N
I n
c G
I I
n c
N N
S I
N N
A N
N U
S D
N A
U P
S Helianthus eggertii Eggert's sunflower N
N N
U S
I N
S D
S I
S D
S D
N S
D N
N A
N N
N S
D N
A U
I L
Panax quinquefolius Ginseng N
N N
U N
S D
N N
N N
N S
D N
N A
N U
U S
D N
A U
I L
Scutellaria montana Large-flowered skullcap N
N S
I U
S I
N N
S I
N N
N S
D N
N A
N N
N S
D N
A U
P S
Dalea foliosa Leafy prairie-clover N
N S
I U
S I
N N
N I
n c
G I
S D
N N
N N
A N
N N
S I
N A
U M
V Clematis morefieldii Morefield's leatherflower N
N N
U S
I N
N I
n c
N N
N N
U N
A N
N N
U N
U P
S Buckleya distichophylla Pirate bush N
N N
U I
n c
S D
N I
n c
N N
N N
N N
A N
U N
U U
U P
S Apios priceana Price's potato bean N
N S
I U
S I
N N
S I
N N
N S
D N
N A
N N
N U
N U
P S
Astragalus bibullatus Pyne's ground-plum N
I n
c G
I U
I n
c N
N S
D I
n c
N N
S D
N I
n c
N N
A N
N U
I n
c N
A U
E V
Hedyotis purpurea var. montana (syn.
Houstonia montana)
Roan Mountain bluet/Venus' pride N
S I
N U
I n
c G
I G
I G
I N
N N
N N
N A
N N
U U
U U
E V
Gymnoderma lineare Rock gnome lichen N
I n
c I
n c
N I
n c
S I
I n
c G
I I
n c
N N
N N
N A
N N
N U
U U
E V
Climate Change Vulnerability Assessment for Tennessee Wildlife and Habitats Page 104 Table 24. Indirect exposure and sensitivity factors for selected Tennessee plants Scientific Name Common Name Indirect Exposure Factors Sensitivity Factors Sea-level rise Natural barriers Anthropogenic barriers Human response to climate Dispersal and movements Historical thermal niche Physiological thermal niche Historical hydrological niche Physiological hydro niche Dependence on disturbance Dependence on ice, snow Restricted habitat features Depend on spp for habitat Dietary versatility (animals)
Pollinator versatility (plants)
Propagule dispersal Other interspecific interaction Measured genetic variation Evolutionary Bottlenecks Phenological response Index Score S
I Pityopsis ruthii Ruth's golden aster N
G I
N U
S I
N N
G I
N N
N S
I N
N A
N N
N I
n c
N A
U E
V Physaria globosa (syn. Lesquerella globosa)
Short's bladderpod N
S I
I n
c U
S I
N N
S D
I n
c N
S D
N N
N N
A N
N U
U S
I U
H V
Isotria medeoloides Small whorled pogonia/little five leaves N
N N
U N
N N
I n
c N
N N
D e
c N
N A
N N
N S
I N
A U
P S
Geum radiatum Spreading avens/
Appalachian avens N
G I
I n
c N
N N
S I
I n
c S
I N
N S
D N
N N
N A
N N
N S
I N
A U
H V
Paysonia perforata (syn.
Lesquerella perforata)
Spring Creek bladderpod N
I n
c G
I I
n c
S I
N N
G I
S I
N N
N N
N A
N N
N N
N A
U E
V Echinacea tennesseensis Tennessee purple coneflower N
N I
n c
U S
I N
S D
G I
N S
D N
N N
N A
N N
N N
N A
U M
V Xyris tennesseensis Tennessee yellow-eyed grass N
I n
c N
U U
N N
G I
G I
N N
N N
N A
N U
U I
n c
N A
U E
V Spiraea virginiana Virginia spiraea/
Virginia meadowsweet N
I n
c N
U I
n c
N N
S I
I n
c N
N N
N N
A N
N N
S I
N A
U H
V Platanthera integrilabia White fringeless orchid/
monkey-face orchid N
S I
S I
U N
N N
I n
c G
I N
N N
N N
A S
I U
S I
U U
U H
V Helianthus verticillatus Whorled sunflower N
N I
n c
U S
I N
N G
I G
I N
N S
I N
N A
N N
N S
D N
A U
E V