ML18023A184
| ML18023A184 | |
| Person / Time | |
|---|---|
| Site: | Clinch River |
| Issue date: | 01/23/2018 |
| From: | Oak Ridge |
| To: | Office of New Reactors |
| Fetter A | |
| References | |
| Download: ML18023A184 (90) | |
Text
DOCUMENT AVAILABILITY Reports produced after January 1, 1996, are generally available free via the U.S. Department of Energy (DOE) Information Bridge.
Web site http://www.osti.gov/bridge Reports produced before January 1, 1996, may be purchased by members of the public from the following source.
National Technical Information Service 5285 Port Royal Road Springfield, VA 22161 Telephone 703-605-6000 (1-800-553-6847)
TDD 703-487-4639 Fax 703-605-6900 E-mail info@ntis.gov Web site http://www.ntis.gov/support/ordernowabout.htm Reports are available to DOE employees, DOE contractors, Energy Technology Data Exchange (ETDE) representatives, and International Nuclear Information System (INIS) representatives from the following source.
Office of Scientific and Technical Information P.O. Box 62 Oak Ridge, TN 37831 Telephone 865-576-8401 Fax 865-576-5728 E-mail reports@osti.gov Web site http://www.osti.gov/contact.html This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise, does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof.
Background photo of cave salamanders courtesy of Sarah Brown
ORNL/TM-2009/296 Environmental Survey Report for ORNL:
Reptile and Amphibian Abundance and Distribution Survey Oak Ridge National Environmental Research Park 2007-2009 Neil R. Giffen Environmental Sciences Division, Oak Ridge National Laboratory R. Scott Reasor ORISE Brittany L. Petersen ORISE Claire A. Campbell ORISE Date Published: December 2009 Prepared for OAK RIDGE NATIONAL LABORATORY Oak Ridge, Tennessee 37831-6283 managed by UT-BATTELLE, LLC for the U.S. DEPARTMENT OF ENERGY under contract DE-AC05-00OR22725
iii CONTENTS Page LIST OF FIGURES................................................................................................................................ v LIST OF TABLES............................................................................................................................... vii ACRONYMS........................................................................................................................................ ix ACKNOWLEDGMENTS..................................................................................................................... xi EXECUTIVE
SUMMARY
................................................................................................................. xiii ABSTRACT......................................................................................................................................... xv 1.
INTRODUCTION.......................................................................................................................... 1 2.
METHODS AND MATERIALS................................................................................................... 1 3.
SUPPLEMENTAL STUDIES........................................................................................................ 3 4.
RESULTS....................................................................................................................................... 3 5.
DISCUSSION................................................................................................................................. 4 6.
CONCLUSION.............................................................................................................................. 6 7.
REFERENCES............................................................................................................................... 7 Appendix A. Life Histories of the Reptiles and Amphibians of the Oak Ridge Reservation............. A-1 Appendix B. Description of Sampling Methods................................................................................. B-1 Appendix C. Acoustic Anuran Survey Data....................................................................................... C-1 Appendix D. Species Abundance Inventory Data.............................................................................. D-1 Appendix E Clinch River Environmental Studies Organization Results.......................................... E-1 Appendix F. Reptiles and Amphibians of the Oak Ridge Reservation.............................................. F-1
v LIST OF FIGURES Figure Page
- 1.
Map of sites on the Oak Ridge Reservation sampled during the 2007-2009 reptile and amphibian abundance and distribution survey............................................................................. 2
- 2.
Comparison of method effort and specimen occurrence. Left: 2008; right: 2009.......................... 4
- 3.
Significant survey locations. Top: Bearden Creek, middle: mesophytic forest, bottom: Amphibian Site 5............................................................................................................. 6
vii LIST OF TABLES Table Page
- 1.
Reptile and amphibian species recorded (2007-2009)................................................................... 5
ix ACRONYMS CRESO Clinch River Environmental Studies Organization ORNL Oak Ridge National Laboratory ORR Oak Ridge Reservation
xi ACKNOWLEDGMENTS The authors of this study would like to thank Patricia D. Parr, Facilities and Operations Directorate, for facultative and administrative support throughout the study. We would also like to extend special thank to David Page of the Department of Energy for his support during this project.
For mapping and graphics we appreciate the help of Harry Quarles, Oak Ridge National Laboratory Environmental Sciences Division, and Sherri Cotter, Facilities Development Division. Data collaboration on turtles in Solway Bend provided by John G. Byrd and his students, Clinch River Environmental Studies Organization, was a great contribution to the study. Jim Evans and Sam Young, Tennessee Wildlife Resources Agency, provided great technical support throughout the entire study. Also, thanks to Oak Ridge National Laboratory and the Department of Energy for allowing the study to be conducted on the Oak Ridge Reservation.
xiii EXECUTIVE
SUMMARY
This document summarizes the results of a 3 year Oak Ridge Reservation-wide reptile and amphibian survey. The survey was conducted in the spring and summer of 2007, 2008, and 2009. It was accomplished with the services of interns in the Oak Ridge Institute for Science and Education Higher Education Research Experiences Program. The survey was designed to sample locations that had been sampled in previous surveys as well as certain new locations of interest.
Two supplemental studies were carried out concurrently with the abundance survey. A ranavirus study was conducted in cooperation with the University of Tennessees Wetlands Diseases Laboratory. The project involved the collection of small samples clipped from the tails of a number of salamanders collected during the ongoing abundance and distribution survey. Supplemental studies were also conducted by the Clinch River Environmental Studies Organization during the 2007-2009 time frame. In a program funded by the Department of Energy, middle and high school students collected data from turtles trapped in hoop nets at the two Solway Bend ponds that were also sampled during the overall study.
Certain sampling sites in the study area are particularly notable for either high capture rates or suitability of habitat for target species. Of those, Amphibian Site 5, Bearden Creek, the mesophytic forest, and Hembree Marsh in particular, should be highlighted as significant locations for the management of reptile and amphibian populations.
xv ABSTRACT As a follow-up to a 1996 abundance and diversity study, we conducted reptile and amphibian abundance and diversity surveys during May through July in 2007, 2008, and 2009. The surveys were conducted in the Oak Ridge National Environmental Research Park, located on the U.S. Department of Energys Oak Ridge Reservation (ORR), in Tennessee. The area encompasses 33,654 acres. Our survey incorporated 20 separate sites on the ORR. The habitats covered during this study ranged from upland forested areas to low bottom wetland and stream areas. Several of the sites included native warm-season grass and old field locations. During the survey all captured reptiles and amphibians were released at the point of capture after identification and recording of measurements. The measurements were taken for future growth data analysis and included the specimens weight, total length, and snout-to-vent length; for turtles we recorded just the length of carapace (top of the shell),
the length of the plastron (bottom of the shell), and the depth of the shell. During the survey we used seven methods of capture: visual encounter surveys, artificial cover objects (wood and metal), pitfall traps with drift fence lines, minnow traps, dip nets, hoop nets, and acoustic surveys. In total, 360 specimens of 35 species were recorded during the survey. Two species of interest that we encountered were the northern cricket frog (Acris crepitans) and the four-toed salamander (Hemidactylium scutatum).
1
- 1. INTRODUCTION The 2007-2009 reptile and amphibian abundance and diversity survey project was undertaken to update information about reptiles and amphibians on the Oak Ridge Reservation (ORR). The project was managed by UT Battelle and Oak Ridge National Laboratory (ORNL) and was funded through the ORR natural resources budget. Surveys were conducted by interns from the University of North Carolina at Pembroke, the University of Tennessee, Knoxville who were participating in the Oak Ridge Institute for Science and Education Higher Education Research Experiences Program.
The survey was part of an ongoing effort to measure the abundance and diversity of reptiles and amphibians on the ORR. (Complete life histories of the reptiles and amphibians of the ORR are contained within Appendix A.) The surveys were designed to target all reptiles and amphibians that inhabit the ORR. Twenty-three separate sites were surveyed, including upland hardwood forests, bottomland flooded areas, creeks, farm ponds, and caves (Fig. 1). The study was conducted during the spring and summer (May through July) of 2007, 2008, and 2009. Seven inventory methods were used during the study: visual encounter surveys, artificial cover objects (wood and metal), pitfall traps with drift fence lines, minnow traps, dip nets, hoop nets, and acoustic surveys (Appendix B).
The objectives of this study were as follows:
characterize patterns in the distribution and abundance of reptiles and amphibians in various wetland and upland locations and record species and numbers of reptiles and amphibians frequenting the Reservation.
- 2. METHODS AND MATERIALS The ORR comprises 33,654 acres of mixed upland hardwoods, pine stands, native warm-season grasslands, maintained power line corridors, and bottomland wetlands. There are several active creeks and springs flowing within the ORR. The area has no silvicultural disturbances, and fire management is restricted to the native warm-season grassland fields (N. R. Giffen, J. W. Evans, and P. D. Parr, 2007. Wildlife Management Plan for the Oak Ridge Reservation, ORNL/TM-2006/155, Oak Ridge National Laboratory, Oak Ridge, Tennessee.).
Nine predetermined sites and 14 additional sites were surveyed (Fig. 1).The 2007 survey was limited to eight sites and methods were restricted to visual encounter surveys and dip-netting. In 2008, 8 to 13 wooden cover objects were placed at four sites and five to ten metal cover objects were placed at four additional sites. The type of cover object used was determined by habitat type. Metal cover objects were used in native warm-season grassland fields and old fields. The metal was corrugated roofing tin cut into 4 x 2 ft pieces. Wooden cover objects were used in upland hardwoods, wooded marshes, and wooded creek beds. All cover objects were checked for any activity three times per week throughout the study period.
Seven pitfall traps were installed along both sides of a drift fence line at the Hembree Marsh site, a bottomland wooded marsh. The pitfall buckets were 12 in. in diameter and 12 in. in height. Each bucket was set into the substrate so that the rim was flush with the ground surface. All of the pitfalls were placed along the drift fence, touching the bottom of the fence to ensure capture. Small holes were drilled in the bottom of each bucket to allow drainage. Wet sponges were placed in the buckets to provide moisture for any trapped amphibian species to guard against desiccation. The drift fence
2 Fig. 1. Map of sites on the Oak Ridge Reservation sampled during the 2007-2009 reptile and amphibian abundance and distribution survey.
was a 20 ft section of silt fencing. The bottom edge of the drift fence was staked with metal pins to prevent specimens from escaping under the fencing. Other passive trapping efforts included setting minnow traps in marshes and ephemeral pools and the use of hoop nets in ponds. A description of sampling methods is given in Appendix B.
Minnow traps were effective in trapping a variety of amphibians, especially tadpoles and larval salamanders. During the study minnow traps were set in trap lines of 15 to 20 traps per line. The number and placement of minnow traps were based on the size and on the water level of the trapping area. Hoop nets were used in ponds and wetland complexes to capture turtles. Number and placement of the traps were again based on the size of the trapping area and water levels. We used various baits (e.g., canned sausages or sardines) to make the hoop nets more attractive to turtles.
3 Active trapping was conducted through visual encounter surveys. Throughout all of the sites, visual encounter surveys were conducted on a weekly basis. Logs and rocks were randomly flipped to determine any presence or activity. Surveys were conducted extensively at creek and spring sites in the area. During the creek and spring surveys, both submerged and exposed rocks were randomly flipped, and substrate was sifted through dip nets. Reptiles and amphibians were also incidentally observed out in the open around the survey sites.
Acoustic monitoring for anuran (frog) vocalizations was also conducted during the survey. Ten fixed monitoring locations evenly distributed throughout the ORR were chosen for acoustic monitoring. All of the locations for acoustic monitoring were located near anuran habitat. Monitoring was begun 30 min after sunset. A period of 5 min was assigned to each of the ten fixed locations to listen to and to record any vocalizations heard. A call index scale (from 1, being the least intensive, to 3, being the most intensive) was used to measure the intensity of the vocalizations. A call index of 1 was assigned for vocalization from a specimen of a species. Overlapping vocalizations from the same species received a call index of 2. If calls were overlapping with three or more specimens to a whole chorus, a call index of 3 was recorded. Species recorded of anurans during the survey are represented in Appendix C. Individual anuran captures recorded during all other survey methods is given in Appendix D.
- 3. SUPPLEMENTAL STUDIES In 2008, the University of Tennessees Wetlands Diseases Laboratory requested ORNLs cooperation on a regional ranavirus study. After a review by the ORNL Animal Care and Use Committee and amendment of the Oak Ridge Reservation Reptile and Amphibian Survey Project Animal Care and Use Committee Protocol (#354), a cooperative effort was commenced. The project involved the collection of small samples clipped from the tails of a number of salamanders. The salamanders collected for tail clipping were those caught during the ongoing abundance and distribution survey. After collection, salamanders were placed in individual ziplock bags. Latex gloves were worn, and working surfaces and instruments were sterilized with chlorhexidine between the processing of each specimen to prevent risk of cross contamination. Each specimen was weighed and measured. A very small portion of its tail tip was clipped with standard nail clippers and was transferred into a sterile centrifuge tube. The tubes were placed into a sealed bag and were kept on dry ice until they could be transferred into a subzero freezer at the University of Tennessee.
Additional studies were also conducted by the Clinch River Environmental Studies Organization (CRESO) during the 2007-2009 time frame. This U.S. Department of Energy-funded outdoor studies program serves as an important educational opportunity for middle and high school students as they collect important biological information. The students collected data from turtles trapped in hoop nets at the two Solway Bend ponds that were also sampled during the overall ORR survey. The information collected by CRESO is contained in Appendix E.
- 4. RESULTS During the sampling period, we recorded 35 reptile and amphibian species (Table 1). The four-toed salamander, recorded in 2009, is listed by the state of Tennessee as being in need of management. During 2007, we identified 16 species and recorded between 40 and 100 specimens. In 2008, we identified 32 species and recorded 119 specimens. During 2009 we identified 33 species and recorded 187 specimens. A historical list of species found on ORR is given in Appendix F. A full record of all specimens captured during the study is given in Appendix D. For 2008 and 2009 we logged the sampling effort and time spent in the field. We compared the data with the occurrence of specimens and were able to produce a catch-per-effort analysis (Fig. 2). The visual encounter survey was the most effective sampling method.
4 MT VES PF CO HN DN
% occurence
% effort 0
5 10 15 20 25 30 35 40
% Effort / Occurence MT VES PF CO HN DN
% occurence
% effort 0
10 20 30 40 50 60
% Effort / Occurrence Fig. 2. Comparison of method effort and specimen occurrence. Left: 2008, right: 2009.
- 5. DISCUSSION Weather likely had an effect on capture rates, especially for amphibians. Reptile and amphibian encounters were lower than expected for the area during 2007 and 2008. It is believed that drought conditions, particularly in 2007, contributed significantly to the lack of encounters. Amphibian movements, reproduction, and other behaviors can be significantly affected by such conditions. This is particularly true because so many amphibian species depend on adequate water levels for breeding and larval development. Salamander mortality was noted in 2007 in certain streams where larvae were restricted to small stagnant pools of water where water would be flowing in normal conditions.
During 2009 the precipitation increased to nearly average levels, and the sampling yield increased over that period.
All of the sampling methods used in the study were standard methods that are commonly used in most presence and abundance studies. Some of the sampling methods were modified to better fit each of the sampling sites in the survey. All of the sites were observed and evaluated prior to the implementation of any sampling method. The type of sampling was determined by habitat type and location. Once each site was assigned a sampling method, that method was used throughout the entire survey.
Upon capture of a specimen, several measurements were collected for future population growth analysis. Subsequent to capture, all individuals were placed into a sampling bag. The individual was first identified to species, if possible. Measurements varied, depending on the group. We measured snout-to-vent lengths (the length from the tip of the snout to the cloaca) of salamanders, lizards, and snakes. We also measured their total length. The total length is measured from the tip of the snout to the tip of the tail.
The measurements were different for turtles. We recorded just the length of carapace (top of the shell), the length of the plastron (bottom of the shell), and the depth of the shell. A complete record of the measurements is given in Appendix D.
Certain sampling sites in the study area were particularly notable for either high capture rates or suitability of habitat for target species. Of those, Amphibian Site 5, Bearden Creek, Hembree Marsh, and the mesophytic forest (Fig. 3), in particular, should be highlighted as significant locations for the management of reptile and amphibian populations.
5 Table 1. Reptile and amphibian species recorded (2007-2009)
Common name Genus and species Salamanders and newts Cave salamander Eurycea lucifuga Marbled salamander Ambystoma opacum Northern dusky salamander Desmognathus fuscus fuscus Two-lined salamander Eurycea bislineata Northern red salamander Pseudotriton ruber ruber Spotted dusky salamander Desmognathus fuscus conanti Spotted salamander Ambystoma maculatum Three-lined salamander Ambystoma maculatum Long tail salamander Eurycea longicauda Four toed salamander Hemidactylium scutatum Red-spotted newt Notophthalmus viridescens viridescens Lizards Five-lined skink Eumeces fasciatus Southeastern five lined skink Eumeces inexpectatus Broad head skink Eumeces laticeps Snakes Eastern king snake Lampropeltis getula getula Ring necked snake Diadophis punctatus edwardsii Northern brown snake Storeria dekayi dekayi Northern water snake Nerodia sipedon sipedon Smooth earth snake Virginia valerie Northern redbelly snake Storeria occipitomaculata Northern copperhead Agkistrododn contortrix Toads and frogs American toad Bufo americanus Eastern narrow-mouthed toad Gastrophryne carolinensis Southern leopard frog Rana utricularia Northern cricket frog Acris crepitans Green frog Rana clamitans Spring peeper Pseudacris crucifer Turtles Eastern spiny softshell Apalone spinifera spinifera Eastern box turtle Terrapene carolina Common musk turtle Stenotherus odoratus Painted turtle Chrysemys spp.
Snapping turtle Chelydra serpentina Yellow-bellied slider Trachemys scripta scripta Cumberland slider Trachymes scripta troostii
6
- 6. CONCLUSION During this study we were able to survey 23 sites distributed throughout the ORR. We evaluated the presence, abundance, and species diversity of aquatic and terrestrial reptiles and amphibians throughout all of the study sites. Out of the sites evaluated, 16 included wetland and other aquatic complexes. During the study we maintained collaboration with the Tennessee Wildlife Resources Agency, CRESO, and the University of Tennessee, Knoxville. Through this study we have been able to start characterizing patterns in the distribution and abundance of certain species on the ORR. An ongoing reptile and amphibian inventory is beneficial to land managers and wildlife biologists for future management considerations on the ORR.
Fig. 3. Significant survey locations. Top:
Bearden Creek, middle: mesophytic forest, bottom:
Amphibian Site 5.
7
- 7. REFERENCES Buhlmann, K., T. Tuberville, and W. Gibbons. 2008. Turtles of the Southeast. The University of Georgia Press, Athens, Georgia.
Conant, R., and J. T. Collins. 1998. Reptiles and AmphibiansEastern/Central North America.
Houghton Mifflin Company, New York, New York.
Corn, P. S., and R. B. Bury. 1990. Sampling Methods for Terrestrial Amphibians and Reptiles.
U.S. Department of Agriculture, Forest Service. General Technical Report PNW-GTR-256.
Giffen, N. R., J. W. Evans, and P. D. Parr. 2007. Wildlife Management Plan for the Oak Ridge Reservation. ORNL/ TM-2006/155. Oak Ridge National Laboratory, Oak Ridge, Tennessee.
Heyer, R. W., M. A. Donnelly, R. W. McDiarmid, L. C. Hayek, and M. S. Foster. 1994. Measuring and Monitoring Biological Diversity Standard Methods for Amphibians. Smithsonian Institution Press. Washington, D.C.
Jensen, J. B., C. D. Camp, W. Gibbons, and M. J. Elliott. 2008. Amphibians and Reptiles of Georgia.
The University of Georgia Press, Athens, Georgia.
Mitchell, J. M., E. R. Vail, J. W. Webb, J. W. Evans, A. L. King, and P. A. Hamlett. 1996. Survey of Protected Terrestrial Vertebrates on the Oak Ridge Reservation. ES/ER/TM-188/R1. Oak Ridge National Laboratory, Oak Ridge, Tennessee.
APPENDIX A.
LIFE HISTORIES OF THE REPTILES AND AMPHIBIANS OF THE OAK RIDGE RESERVATION
A-3 APPENDIX A. LIFE HISTORIES OF REPTILES AND AMPHIBIANS OF THE OAK RIDGE RESERVATION A.1 AMPHIBIANS A.1.1 Frogs and Toads American ToadBufo americanus The American toad ranges from as far south as northern Mississippi, west as far as eastern Oklahoma, and as far north as the Canadian border. The American toad is found throughout the Northeast and is considered quite common.
American toads thrive in several habitats, from dense forests to open disrupted areas. They rely on shallow bodies of water, moist cool cover, and an abundant prey base of insects. Young American toads need especially dense vegetation for prey availability and generally are found near and in permanent water sources. During colder months, American toads lie dormant in leaf litter. They will often disperse to a separate area from breeding pools to overwinter.
In the summer months, the toads are most likely found under logs and in other shaded areas. Considered nocturnal, they are most active around dusk, when they come out to forage for insects and worms. The toads remain solitary until breeding season, at which time they then move into large breeding pools.
American toads typically mate from March to April, but breeding has been known to extend until July in colder climates. Males usually arrive at breeding pools early to establish territories and then attract the females with vocalizations. As with most frogs and toads, fertilization is external; the female lays 2,000 to 20,000 eggs in long rows. They are then externally fertilized. Depending on temperature, the eggs hatch within 3 to 12 d. Tadpoles take 40 to 70 d to develop. Sexual maturity occurs at 2 to 3 years.
The lifespan of most American toads never normally exceeds 1 to 2 years. Since they are adaptable to their environment and can thrive in so many locations, they are not at risk of endangerment. The species is stable throughout the eastern United States.
Gray TreefrogHyla versicolor The gray treefrog ranges from northern Florida to southern Maine and as far west as central Texas. Large populations have been established in Tennessee and North Carolina. This species is similar to Copes gray treefrog (Hyla chrysoscelis) but can be distinguished by the call. It is possible that these two species have begun to hybridize in certain overlapping locations.
Gray treefrogs generally prefer riparian zones or thick woody stands with in 500 ft of wet areas. They generally remain in trees or taller vegetation, where they are free of most predators and are closer to their food sources. During mating season, they move closer to water sources to lay eggs, usually on trees and bushes that hang over water. During winter, the treefrogs are inactive and use coarse woody debris as cover.
Photo by Robert English, LEAPS Environmental Consulting
© 2009 Photo by Robert English, LEAPS Environmental Consulting © 2009
A-4 Gray treefrogs are territorial during breeding season, but they group during most of the summer months. Their prey consists of insects, smaller amphibians, and algae.
The gray treefrogs breeding season runs from April to May. The females are dominant during breeding seasons; they approach males by responding to male vocalizations. The frogs reproduce using external fertilization.
The gray treefrogs are relatively common and appear to be at no risk of extinction. While most individuals are subject to predator-related deaths, along with diseases and other incidents, the treefrogs are known to live up to 7 years (in captivity). This species is stable.
Copes Gray TreefrogHyla chrysoscelis Copes gray treefrogs are present throughout the eastern United States from central Texas to the Atlantic Ocean. Significant populations are missing in southern Florida and Maine. Copes gray treefrogs thrive in several habitats, including woodlands, swamps, and even residential areas. They prefer moist slopes in hardwood forests.
The Copes treefrog breeds from March to August, but breeding can be delayed during drought years. Females lay 20 to 40 eggs in masses and can produce up to 2,000 eggs. The eggs hatch within 2 to 5 d and develop to the tadpole stage after 30 to 60 d. They become sexually mature in 2 years.
Copes treefrogs feed on insects. Their skin tissue contains antifreeze components, and they are known to survive temperatures below freezing. The treefrogs have very cryptic skin markings, which enable them to avoid predators. The populations appear stable, and their lifespan is up to 7 years.
Upland Chorus frogPseudacris feriarum The upland chorus frog ranges from Floridas panhandle to northern New Jersey and as far west as central Texas.
Isolated populations have been found on the coastal plains of South Carolina and Georgia. These frogs usually occur at higher elevations.
The upland chorus frogs habitat varies based on location.
In the North, populations are found in moist woodlands and swamps; in the South, they are commonly found in lowlands near rivers and coastal plains.
During the summer, upland chorus frogs inhabit cool, dark areas and emerge at night to forage for small insects and spiders. On very humid days, they may be spotted in the open. Because of their small size, they are difficult to spot, even with their continuous calling throughout the day. Their small size enables them to disperse unnoticed into open meadows, where they have better access to water and food.
During breeding season, from February to May in the North and late winter to early spring in the South, their calls become prevalent both day and night. Males tend to stay at breeding pools throughout the season whereas females arrive to deposit eggs and leave immediately. The population is stable.
Photo by Scott Reasor Photo by Robert English, LEAPS Environmental Consulting © 2009
A-5 Eastern Narrow-Mouthed ToadGastrophryne carolinensis The eastern narrow-mouthed toad is known for its distinctive teardrop shape, which is accentuated by a narrow face that ends in a tip at its snout. Another distinctive characteristic is the fold of skin above the eyes.
Found throughout the Southeast, as far south as the Florida Keys and as far west as central Texas, these toads can thrive in almost any habitat. They require only cover, moisture, and a steady insect pray base. Known for their burrowing ability, they are often difficult to locate.
These toads are primarily nocturnal and are most active from March to September. Their diet consists of termites, ants, and beetles. As tadpoles, they rely on small floating organisms for nutrition.
During breeding, the males secrete sticky glue used to help remain on the female during amplexus.
Females usually lay 100 to 150 eggs. Males reach maturity in about 1 year; females mature in 1 to 2 years. Currently, the eastern narrow-mouthed toad has stable and growing populations throughout its range.
Green FrogRana clamitans melanota Green frogs range from Canada to parts of Florida and as far west as Oklahoma. They do not have established populations in Illinois or Indiana but seem prevalent in all other regions.
Found in permanent and temporary water sources, green frogs are abundant in streams, rivers, bogs, marshes, and ponds. They can sustain themselves wherever fresh, shallow water is available.
Green frogs are dormant in winter, usually burrowing into substrate. During summer, they are most active at night, although they can be heard calling during the day. They feed on insects, snails, slugs, and crayfish as well as smaller frogs and snakes.
During breeding season (from April to August), vocalizations are very distinct, similar to that of a loose banjo string being plucked. During breeding they are territorial, with males making domains approximately 1 to 6 m in diameter. Females choose males based primarily on location (on where their eggs are most likely to succeed). Female green frogs lay 3,000 to 5,000 eggs, which mature after 3 to 22 months.
Green frogs in captivity have lived up to 10 years, but their lifespan in the wild is unknown. Their populations are stable throughout their range.
Photo by Robert English, LEAPS Environmental Consulting
© 2009 Photo by Robert English, LEAPS Environmental Consulting © 2009
A-6 Pickerel FrogRana palustris Pickerel frogs are commonly found from southern Canada as far south as the Carolinas and as far west as eastern Texas and southeastern Minnesota. There are however, large populations missing from areas in the southern portions of Ohio, Illinois, and Indiana.
Pickerel frogs thrive in areas where they have access to cool, clean spring water. They are found near streams and lime-rich ponds and are often found in caves. During summer, they are usually found near water and are nocturnal. At the end of October they go dormant by burrowing into the sediment at the bottom of ponds or pools of water.
Pickerel frogs breeding pools are large, with as many as fifteen pairs in just a few square meters. The breeding period occurs from March to May; males attract females with vocalizations that can be recognized underwater. The frogs are larval for 3 months and become sexually mature after 2 years.
When pickerel frogs are attacked, they secrete a poison from specialized glands that makes them distasteful to predators. The secretion can irritate human skin and can be fatal to the pickerel frogs predators.
Populations are stable, but there is some concern that urbanization will have an impact on their natural habitat.
Southern Leopard FrogRana utricularia The southern leopard frog ranges from New Jersey to Florida and as far west as Kentucky and eastern Texas. The frogs breed in aquatic habitats but generally disperse to drier land when they are not breeding. They thrive in moist vegetation and can disperse extended distances (1 to 5 km) away from water.
The southern leopard frogs have a diet consisting of insects.
Some larger individuals feed on small invertebrates (this activity is very rare). Southern leopard frogs are primarily nocturnal; during the day, they shelter in vegetation near the waters edge. The frogs escape from predators by either diving below the waters surface or using their powerful hind limbs to distance themselves.
Southern leopard frogs breed throughout the year, primarily when heavy rainfall occurs. Breeding time frames are usually related to location. In the North, the frogs breed in the spring; in the South they breed during winter. Because they can breed throughout the year, some believe that they can breed more than once a year, especially in areas that receive heavy rainfall more than once a year. The eggs hatch in approximately 1 week. The tadpoles develop into frogs in 90 d, and the frogs reach sexual maturity in 1 to 2 years.
Migration patterns in this species have not been considerably studied, but they are believed to disperse long distances from their water sources. Their lifespan in the wild is thought to be 2 to 3 years.
The species is considered stable and has large populations where it is found.
Photo by Brittany Petersen Photo by Robert English, LEAPS Environmental Consulting © 2009
A-7 Northern Cricket FrogAcris crepitans Northern cricket frogs are found from New York and Pennsylvania to southern Louisiana and as far west as western Texas and Oklahoma. They are common around sunny ponds and can also be found in dense wetland vegetation. During high humidity, the frogs have been spotted much farther from their ponds, but they usually remain near water.
Northern cricket frogs can be spotted at any time of the day and are active at all hours during warm weather. In cold weather they remain inactive under shelter such as leaf litter or logs. The frogs prey on insects. They are preyed upon by snakes, such as northern watersnakes and garter snakes.
These frogs breed from March to August. The males emit a clicking vocalization to attract females, and, when in a large chorus, the males sound like a group of crickets. Females can produce more than one egg mass each season. The egg masses are laid in shallow pools. The frogs reach sexual maturity in 1 year.
The northern cricket frog was common until the 1970s but has seen continuing population declines since that time. Large populations once existed throughout the Northeast, but now the frog is common in the southern and western portions of its range. In Tennessee, the frogs are not considered as being of special concern, but they are in South Carolina.
A.1.2 Salamanders Spotted SalamanderAmbystoma maculatum Spotted salamanders are found throughout eastern North America. Some regions, including coastal regions, lack large populations of the species, and it is not found in eastern North Carolina. Spotted salamander habitats are abundant in bottomland floodplain with hardwood forests and can be common in upland hardwood forests if they find breeding sites. They breed in temporary pools, low spots in floodplains, ditches, and beaver ponds.
They are aggressive predators and primarily eat earthworms, insects, snails, slugs, millipedes, and some centipedes. As larva, they become cannibalistic when their habitats (vernal pools) dry up and overpopulation occurs.
To mate, males and females gather at breeding ponds and begin nudging each other so they become stimulated and ready to breed. The salamanders remain in their breeding ponds for 2 or 3 d. Males produce spermatophores and deposit them on foliage near the waters surface. Females then pick the spermatophores up using their cloacae and begin internal fertilization. Then females lay egg masses in a hard clear jelly to protect the eggs from predators. Once hatched, the larvae take approximately 6 months to develop.
Spotted salamanders have a long lifespan. However, most do not reach maturity due to predation. The spotted salamander is still a common species, but because it relies heavily on vernal pools for breeding, populations may be declining rapidly.
Photo by Robert English, LEAPS Environmental Consulting
© 2009 Photo by Scott Dykes ©
A-8 Marbled SalamanderAmbystoma opacum Marbled salamanders have ranges in most regions of the eastern United States. While most populations do not live in mountains, they are present in areas with substantial rainfall. Their habitats include wetlands, which are used during the breeding season, and floodplain bottomlands and mature forests, which are used during dispersal events.
Breeding occurs in vernal pools, such as fish-free ponds and floodplain pools.
Marbled salamanders feed on millipedes, centipedes, worms, spiders, snails, and various insects. They are known as aggressive predators. Larvae feed on zooplankton when they first hatch and subsequently feed on aquatic insects and other amphibians until they reach metamorphosis. They then change their foraging habits to a terrestrial prey base.
Marbled salamanders are unique because they practice parental care. After breeding occurs (from September to November), females lay eggs in areas that will flood in the coming months. Then, the females watch over the eggs to make sure that they do not dry out. Female marbled salamanders also tend to lay fewer eggs than other salamanders. Once the water rises, the eggs hatch into a larval stage.
The marbled salamander has a relatively long life cycle. In some locations, rainfall and temperature variations, primarily in the northern side of its range, are hurting the marbled salamanders population considerably. However, populations in the South remain stable.
Spotted Dusky SalamanderDesmognathus fuscus conanti Spotted dusky salamanders have a small range, which includes western Kentucky, eastern Mississippi, Alabama, northern Georgia and the Cumberland Plateau in Tennessee.
Spotted dusky salamanders are often found in the water or near the waters edge in swamps, springs, and temporary pools and streams. Spotted dusky salamanders require moisture, but do not rely heavily on it as do some other Desmognathus species.
Spotted dusky salamanders feed on a variety of earthworms, spiders, centipedes, millipedes, and insects. They are close in identification to northern dusky salamanders. The two species have overlapping ranges. Since the populations generally do not hybridize, they are recognized as separate species. Spotted dusky salamanders are lighter in color with silver or gray flecking on the sides; northern dusky salamanders are darker with clearer spots along the back.
Breeding occurs from late July to October. Females are known to brood over their small nests of 13 to 37 eggs. Hatching takes 5 to 7 weeks, and maturity occurs after 2 to 3 years after an approximately month long larval period.
Within its range, the spotted dusky salamander has a healthy population, especially around optimal habitats. Its lifespan in the wild remains unknown.
Photo by Scott Reasor © Study photo
A-9 Northern Dusky SalamanderDesmognathus fuscus fuscus Northern dusky salamanders range from as far north as Quebec and south to North Carolina and Tennessee. The northern dusky salamander favors habitats with running or seeping water, including streams and waterfalls (where mist is available). They are normally found under rocks and logs along streambeds, and when disturbed they take shelter in the water.
During winter, northern dusky salamanders are known to burrow in substrate below the frost line; however, if it does not get too cold, northern dusky salamanders can remain active all year.
The northern dusky salamander feeds on a large variety of invertebrates, including beetles, spiders, earthworms, slugs, snails, centipedes, moths, mayflies, and ants.
The lifespan of this species remains unknown. They are believed to live up to a decade or more in the wild because similar species have thrived for that long. Northern dusky salamanders are threatened by habitat destruction but are stable in areas where habitats remain undisturbed.
Southern Two-Lined SalamanderEurycea cirrigera The southern two-lined salamander occurs throughout the southeast; however, they do not hybridize with the Blue Ridge two-lined salamander. The southern two-lined salamanders range extends as far north as Ohio, near the southernmost tip of Lake Michigan.
The southern two-lined salamanders like habitats such as small streams, springs, swamps, and hardwood forests surrounding those sites. When not breeding, adults will often burrow in areas far from water, but some salamanders are still found near running water year-round.
The salamanders use rocks and logs for protection but will use smaller vegetation when needed. Larvae thrive in a rocky substrate.
Southern two-lined salamanders feed on terrestrial invertebrates such as spiders and insects. Foraging activity decreases in the winter months, but the salamanders feed year-round.
Breeding is not documented well for this species. The salamanders migrate to breeding streams from the end of December to March and lay eggs under submerged rocks in shallow running water. Females usually lay approximately 50 eggs. Females stay with the nests until they hatch. Hatching occurs within a month, and the larval period lasts 1 to 3 years. The salamanders reach maturity after 2 to 4 years.
The southern two-lined salamander is common and stable throughout its range. Its lifespan remains unknown.
Study photo Photo by Brittany Petersen
A-10 Cave SalamanderEurycea lucifuga Cave salamanders are found in the karst regions of the eastern United States, including Tennessee, Kentucky, southern Ohio, and most of the surrounding states that touch that region.
Cave salamanders live in the twilight zones of caves, where there is still available light but plants can no longer grow. Cave salamanders have also been found up to 1 km away from cave entrances, especially on moist, temperate nights. The salamanders are also known to venture farther into caves, especially during hot, dry days.
The salamanders are primarily nocturnal and are most active on rainy nights. They feed on insects, mites, ticks, and earthworms. Those that feed in the twilight zone usually have a more diverse food base than those that live farther into the caves.
Cave salamanders lay eggs from September to February; the largest populations breed from October to January. Mating occurs during the summer, and eggs are then laid later. The larval period is 6 to 18 months. They reach sexual maturity in 2 years.
The cave salamanders lifespan has not been closely studied due to the environment it thrives in. Cave salamanders are threatened in Kansas and are vulnerable in other portions of their range because of their fragile habitats.
Long-Tailed SalamanderEurycea longicauda longicauda Long-tailed salamanders thrive in karst topography, including middle and eastern Tennessee, West Virginia, Kentucky, Pennsylvania, Ohio, Illinois, and regions of Missouri and Arkansas.
These salamanders thrive in caves but are also found near springs and in damp areas near ponds and streams. During rainy weather, they can disperse away from water. Larvae are often found in water-filled sinkholes, caves, and some surface streams.
Long-tailed salamanders breed from October to February, and females lay their eggs yearly. Females lay up to 100 eggs but spread them out in small groups. The female salamanders do not guard their eggs until hatching. Eggs hatch after 4 to 12 weeks, and the larvae transform in June and July. They reach sexual maturity after 2 years.
Long-tailed salamanders can be distinguished from cave salamanders primarily by the herringbone markings on the sides of their tails. The markings are absent on cave salamanders, which have spotting along the entire length of the tail.
Longevity of the long-tailed salamander has not been studied. The species is common within its range but is sensitive to disturbance, especially in caves. This makes the population somewhat vulnerable.
Photo by John Leeman, ORNL ESD Photo by Scott Dykes
A-11 Northern Slimy SalamanderPlethodon glutinosus complex Northern slimy salamanders range throughout most of the eastern United States with the exception of areas in the extreme northeast. Populations are also limited in Mississippi, where it is believed that rainfall is destroying some habitat.
Northern slimy salamanders thrive in hardwood forests that contain high moisture. They do not swim and avoid most water, so they usually reside on the higher ends of floodplains and slopes, where water can easily drain. Slimy salamanders spend most of their time underground, although individuals are often spotted aboveground. Once the slimy salamander establishes its habitat it rarely disperses range.
Breeding occurs at differing times of year from that depending on location. In the South, mating usually occurs throughout the spring and summer, and eggs are laid in early fall. Females lay approximately 15 eggs and guard the eggs for 2 to 4 months until hatching. The slimy salamanders have a minimal larval period, and often females will stay with the larvae until metamorphosis is complete. Slimy salamanders reach sexual maturity after 3 years.
Northern slimy salamanders are very territorial and will often fight other species or their own to keep their space. The salamanders prey on ants, earthworms, beetles, and other small insects. Their diet depends on their location and on the season. Northern slimy salamanders are most active on warm rainy nights and take shelter in caves and other underground locations in heat and during heavy rainfall. The slimy salamanders main defense mechanism is its tail, which secretes a gluey, noxious substance. Slimy salamanders are not threatened in their range.
Four-Toed SalamanderHemidactylium scutatum Four-toed salamanders are believed to range throughout the eastern United States although their populations appear spotty in areas.
Four-toed salamanders thrive in forested wetlands and are usually found in those regions. However, they are known to travel long distances from water as long as the ground is moist and conditions are favorable.
Four-toed salamanders are very secretive and tend to be most active during breeding season (cold weather months) but are sluggish. In warmer weather, they can move more quickly. These salamanders prey on small insects, spiders, and mites. When attacked or handled, they will voluntarily break off their tails, a characteristic not found in many salamanders.
Four-toed salamanders breed from January to March. Females lay eggs adjacent to water sources, and the eggs hatch 1 or 2 months later. The larval period is short, and the juveniles leave the water after 6 weeks. Sexual maturity is reached at 2 years.
Four-toed salamanders are believed to be rare because of their secretive nature and spotty populations. They are believed to be uncommon and are listed as a species in need of management in Tennessee.
Photo by Scott Dykes Photo by Claire Campbell
A-12 Northern Red SalamanderPseudotriton ruber ruber Northern red salamanders range throughout the southeastern United States and up the eastern seaboard to New York. They are most commonly found in slow-moving permanent streams, near springs, and in some bogs. They rely on heavy leaf litter, logs, and burrows as habitats and can sometimes live in streams that come out of caves.
Northern red salamanders are most active at night and feed on small insects. During rainy nights they will stray far from water.
They are known to give off toxic skin secretions when attacked.
Northern red salamanders mate during fall and summer, and eggs are laid in early fall. Females will often bunch nests together for safety. Once hatched, the larvae take 2 years to metamorphose. Sexual maturity is reached after 4 to 6 years. The northern red salamanders population is stable throughout its range.
Red Spotted NewtNotophthalmus viridescens viridescens Red spotted newts, also known as eastern newts, occur throughout the eastern United States from central Texas to the Atlantic coast. The red spotted newt thrives in a variety of standing freshwater habitats, such as shallow wetlands, beaver ponds, marshes, bays, and artificial ponds.
Red spotted newts have distinct life stages. After hatching, the larvae stay in water for approximately 2 /5 months. Then, the newts transform into their eft stage as juveniles and become terrestrial creatures. After up to 7 years, the efts return to the water as adults. Red spotted newts feed primarily on insects, worms, leeches, larvae, and eggs of amphibians.
Breeding takes place from fall to early summer. Females are attracted to males with their spots and with the chemicals they give off. Amplexus in newts can last several hours, ending when the males release spermatophores on the bottom of the pond. The spermatophores are then picked up by the females. Red spotted newts can live up to 15 years in captivity, but few make it past the larval stage in the wild. Their habitats are plentiful, and they are stable throughout their range.
Photo by Scott Reasor Study Photo
A-13 A.2 REPTILES A.2.1 Lizards Five-Lined SkinkEumeces fasciatus Five-lined skinks are found throughout the eastern United States and as far west as Central Texas. Their range does not extend into the northeast (i.e., most of New York, Maine, Vermont, New Hampshire, and Massachusetts). With such a large range, five-lined skinks rely on a diverse habitat. Most find habitat in wooded areas near the ground in logs, leaf piles, and rocks.
Five-lined skinks change in appearance with age. As juveniles, they show the signature five lines across their backs and have a bright blue tail. As they age, the tail changes to brown or gray, and the lines on the back fade and sometimes disappear.
Five-lined skinks are known to bask on woody debris and are most active on hot days. Adults are active in May; juveniles are active throughout the warm weather months. These lizards are quite skittish and will run from humans and predators. When attacked, they detach their tails, which distract the attacking predator so that the skink can escape.
Five-lined skinks breed in the spring and lay eggs during early summer. Each nest can have up to 14 eggs. Females are protective of their eggs until hatching.
The five-lined skink can live up to 6 years in the wild. The species is experiencing some extirpation because of habitat destruction. The populations are generally stable.
Southeastern Five-Lined SkinkEumeces inexpectatus The southeastern five-lined skink ranges throughout the southeast, especially Florida, Georgia, Alabama, Mississippi, Tennessee, the Carolinas, and regions in Virginia.
Like the common five-lined skink, its habitat includes a diverse range of wooded and disturbed areas. The species tends to bask on woody debris, but it is capable of climbing. It uses crevices and coarse woody debris for cover.
Southeastern five-lined skinks are skittish and are known to climb when they are approached. They also lose their tails when attacked. They are known to eat spiders and some insects, such as crickets and mealworms.
The species breeds in spring and early summer, and the females lay three to eight eggs, sometimes more. The females stay with their eggs until hatching. The species is common in its range. Its lifespan has not been closely studied.
Photo by Claire Campbell Source: The Florida Scrub
© 1997-2001.
A-14 A.2.2 Snakes Eastern Worm SnakeCarphophis amoenus amoenus Eastern worm snakes occur through most of the southeast.
Their habitat includes hardwood forests in high elevations, where they can be found under rocks, logs, and debris. While they have been found in forested wetlands, they are most prominent in dry uplands.
Eastern worm snakes spend most of their time underground or in burrows. They remain inactive on hot days, and their activity peaks during the fall. The snakes can remain dormant for up to 2 weeks at a time. Males travel from their home ranges much more than females. Their diet contains earthworms, invertebrates, and some insect larvae. The snakes are very secretive, and their habits are not well documented.
Breeding takes place in spring and fall, and females lay up to a dozen eggs in June and July. The young reach sexual maturity after 3 years.
Because of their secretive nature, little is known about their lifespan and status. The populations are believed to be dense where their habitats are favorable.
Northern Ringneck SnakeDiadophis punctatus edwardsii The northern ringneck snake occurs in most of the central and eastern parts of the United States, and its range continues along the western coast. Populations are missing in the northwestern United States but are found almost everywhere else.
Northern ringneck snakes rely on a huge variety of habitats, evident by their large range. They shelter under rocks, logs, and leaf cover. The snakes prefer moist conditions but are known to survive without permanent water sources.
Ringneck snakes are primarily nocturnal; however, individuals can be spotted at all times of day. The species rarely bites in defense against predators, and instead plays dead or flips over to reveal its brightly colored stomach and distract its predators. When attacked, the species gives off a strong-smelling musk. The species does not harm humans.
The ringneck snake breeds during spring and fall, and eggs are laid in June and July. Eggs can be laid in communal nests but only where colonies of the snakes are present. The females lay 3 to 10 eggs, and the eggs hatch in 7 to 8 weeks.
Ringneck snakes are common in their range. The species is believed to live up to 10 years in the wild.
Study photo Photo by Scott Dykes ©
A-15 Black KingsnakeLampropeltis getula nigra The range of black kingsnakes spans from the Atlantic coast to the Pacific coast across the United States. The species lives in the southern United States, reaching northern points in New Jersey in the east, in southern Iowa in the central United States, and southwestern Oregon in the west. Kingsnake habitat differs based on location. They are known to thrive in forests, grasslands, wetlands, farmland, deserts, and river bottoms. They are not usually found in dry areas such as sandy banks.
Kingsnakes are active during the day and spend most of their time underground. Their diet consists of small mammals, amphibians, turtles and their eggs, and other snakes.
Kingsnakes are constrictors and will often strike their prey and then curl their body up around it. The snakes are known to fold up longer snakes so that they can be eaten.
Kingsnake mating occurs from March to June. Females lay 3 to 30 eggs in moist substrate, and the eggs hatch after 45 to 60 d, depending on temperature of incubation.
The kingsnake is fairly common and is respected by most humans because it eats other snakes. Its lifespan in the wild remains unknown. It is a docile creature that does not harm humans, so generally it is left alone.
Northern WatersnakeNerodia sipedon sipedon Northern watersnakes range throughout the northeastern United States. Their range extends westward to western Kansas and south to the Gulf of Mexico in Mississippi and Alabama. The northern watersnakes habitat includes any aquatic habitat, especially one with still water, such as a small pond or a marsh where amphibians and fish are present. Northern watersnakes are active year-round but can hibernate in cold periods.
They are active day and night and hunt by ambushing or actively seeking out prey.
Northern watersnakes breed from March to May, and young are born from July to October. Males reach sexual maturity after 3 years; females reach maturity after 5 to 6 years.
The species is thriving throughout its range despite killings by humans when they are mistaken for venomous species.
Photo by Brittany Petersen Photo by Brittany Petersen
A-16 Northern Brown SnakeStoreria dekayi dekayi Northern brown snakes have a large range throughout the eastern United States and extending west to central Texas. Populations are notably missing from southwestern Virginia, West Virginia, eastern Kentucky, and the far northeastern corner of Tennessee.
With such a wide range, the species can live in a number of dry, wooded habitats where a fresh water source is present. Brown snakes even tolerate suburban neighborhoods and will seek refuge in woodpiles and gardens.
Northern brown snakes are active throughout day and night and spend most of their time under leaf cover and underground. The snakes are terrestrial. Their diet consists of worms, snails, insects, spiders, amphibians, and fish. They do not use constriction; instead, they swallow their prey whole. Brown snakes are not venomous and will try to flee when threatened. They release a strong smelling musk when handled.
Northern brown snakes breed from March to May. Before they are born, developing brown snakes gain nourishment from a placenta-like structure instead of a traditional embryonic sac. Females usually give birth to about fifteen young.
The species is stable throughout its large range because of its ability to adapt to habitats. There are no records of their lifespan in the wild.
Red-Bellied SnakeStoreria occipitomaculata The red-bellied snake ranges throughout the eastern United States with notably missing populations in Florida, Indiana, Missouri, and Iowa. Its range extends west to eastern Texas and north into Canada.
Red-bellied snakes live in several habitats, including hardwood and pine forests and land surrounding some swamps and wetlands. They are not likely to be found in open fields because they primarily seek shelter in leaf litter, logs, and rocks on the forest floor.
Red-bellied snakes are active during the day and most active in spring and fall. These snakes spend most of their time hiding but travel overland instead of spending time underground. They are very small and will often curl up their lips to show off their teeth to scare predators when they are threatened. These snakes are harmless to humans; their teeth cannot break through human skin.
The red-bellied snakes lifespan in the wild is not known, but in captivity it can live up to 4 years. It is very common in its range. Humans often kill them, fearing that they are venomous.
Photo by Dr. Paul Kosnik © Pkosnik@TissueGenesis.com Photo by Scott Reasor
A-17 Smooth Earth SnakeVirginia valeriae Smooth earth snakes have a spotty range throughout the southeastern United States. Their range extends through the Carolinas, Georgia, Alabama, Mississippi, Arkansas, Missouri, and parts of Oklahoma and Texas; a small population thrives throughout eastern Tennessee.
Smooth earth snakes find habitat in pine and hardwood forests and in fields near woodlands and are known to inhabit suburban areas.
Smooth earth snakes primarily eat earthworms but are known to eat snails and slugs as well. The snakes rarely bite humans and instead rely on releasing musk and hiding for defense.
Smooth earth snakes are fairly common in their range, but there is very limited information on this species because of its secretive nature.
Northern CopperheadAkistrodon contortrix mokasen The northern copperheads range extends from the Florida panhandle north to Massachusetts and west to central Oklahoma and Kansas. There are many species of copperheads, and the northern copperhead tends to stay in the upper portion of its range.
Copperheads live in forested habitats, especially on rocky hillsides. They have been known to live in some wetlands as well. They live in habitats with lots of cover, especially rocks, leaf litter, and logs. Copperheads are surprisingly common in suburban neighborhoods and can survive even with human development as long as their habitats remain mostly intact.
Copperheads are diurnal during spring and fall but remain nocturnal in the summer. They hibernate in colonies and are considered to be very social snakes. Their diet includes mice, small birds, lizards, amphibians, and some insects, especially cicadas. They will both ambush and forage for food. Juveniles have bright yellow tails, which are used as a lure for some insects.
Copperheads breed in spring and fall; fall-breeding females produce eggs in the springtime. They carry the embryos for 3 to 9 months and give live birth, usually to an average of seven young.
Copperheads are venomous, but their venom is mild compared with that of many other venomous snakes. Copperheads are quite common in their range. They are known to live for up to 18 years.
Photo by Brittany Petersen Photo by Scott Dykes ©
A-18 Black Rat SnakeElaphe obsoleta obsoleta Black rat snakes are common throughout the eastern United States, from central Texas to the Atlantic and from southern Michigan to the Gulf of Mexico. Black rat snakes are most common in wooded habitats but are also found near wetlands and residential regions. They are known for climbing into abandoned buildings and barns.
Rat snakes mate from April to June and sometimes in the fall. Rat snakes lay anywhere from 4 to 40 eggs, with an average of 15 eggs per breeding season. Females often show fidelity and return to the same breeding site year after year. Sexual maturity is reached in 4 years.
Black rat snakes feed on rodents and amphibians along with birds and their eggs. They will often climb high into trees to reach their prey. Eaten by several forms of predators, the black rat snake is known to kink up its body to give the appearance of a stick for protection. The snakes will bite if handled improperly. They are known to hibernate during the winter for 2 to 4 months. They are most active during the day. Black rat snakes are abundant in their range, but their lifespan has not been closely studied.
A.2.3 Turtles Common Snapping TurtleChelydra serpentina The common snapping turtle ranges from the Atlantic Ocean west to the Rocky Mountains and from the Gulf of Mexico north to Nova Scotia. Its huge range is due to its ability to adapt to habitats and to its simple need for fresh or brackish water. Females will even live on land during egg-laying seasons.
Snapping turtles are found in and out of water when dispersing between systems. They are omnivorous, eating almost anything they come across in their aquatic habitat. As their common name describes, snapping turtles are aggressive and will often snap at humans or other attackers. Adult snapping turtles have very few predators because of their thick shells and snapping gestures.
Snapping turtles mate from April to November, depending on warmth and location. Females dig nests in loose soil and lay up to 80 eggs. As is true for many turtle species, the sex of the offspring relies on the temperature of the eggs during their incubation. It takes snapping turtles 10 to 15 years to reach sexual maturity.
Common snapping turtles are common in their range. The species is known to live up to 40 years in the wild.
Photo by Claire Campbell Photo by Brittany Petersen
A-19 Painted TurtleChrysemys picta Painted turtles range throughout the northern United States and into much of the southeast, excluding Florida and southern Georgia. Painted turtles live in muddy-bottomed ponds with shallow water and thick aquatic vegetation. Ideal habitats include farm ponds, lakes, freshwater marshes, reservoirs, and some slow-moving rivers.
Painted turtles are diurnal and generally are most active in early morning or late afternoon. They bask on logs and rocks and are known to bask in large groups at favorable sites.
Painted turtles eat aquatic plants, including algae and duckweed, as well as animals such as aquatic insects, fish, and frogs.
The turtles mate during winter and spring, and females lay eggs from May to July. Females lay clutches of 2 to 14 eggs and are known to lay more than 2 clutches per year. Eggs hatch after 1.5 to 2.5 months. The hatchlings will often double in size over their first year. Males reach maturity at 2 years old; females reach maturity in 6 to 10 years.
Painted turtles are common throughout their range and may be the most common turtle in the United States. Their lifespan has not been closely studied.
Eastern Box TurtleTerrapene carolina carolina Eastern box turtles have an extensive range. Found from central Texas to the Atlantic Coast and from southern Florida to northern Pennsylvania, they are fairly common in most regions east of the Mississippi River.
Eastern box turtles make their habitats in hardwood forests, fields, and even some coastal plains. During warm weather, the turtles have been known to enter wetlands and shallow ponds to cool off.
During the summer, box turtles are active throughout the day. At night they find shallow pits and cover themselves in leaf litter for protection against predators. The eastern box turtle also practices the burying concept during its dormant months in the winter. Box turtles feed on plant material such as mushrooms, roots, flowers, grasses, and berries. They also feed on insects, worms, and small amphibians.
Box turtles mate during spring; mating can continue into late summer. Box turtles mate on land and usually nest from May to July. Females lay 5 to 10 eggs, depending on how many clutches of eggs they lay. Females can reject mating by closing off their shells and are known to store sperm for up to 4 years.
By storing sperm, they do not need to mate and can still lay eggs.
The eastern box turtle has a lifespan of more than 100 years. Many box turtles never live that long due to predation and being run over by vehicles. The turtles are very common, and most threats come from human beings.
Photo by Brittany Petersen Photo by Scott Reasor
A-20 Cumberland SliderTrachemys scripta troostii The Cumberland slider turtle is found along the Cumberland mountain range in Tennessee, in northern Alabama, and in the southwest corner of Virginia. Although slider turtles are found throughout the Southeast, this is the most common range for the Cumberland subspecies. The Cumberland slider lives in swamps, ponds, slow-moving rivers, and floodplains. The species thrives most in silt-bottomed water with heavy vegetation and log accumulation. They are known to travel overland and to colonize wetlands.
Sliders are active in warm weather, in both summer and winter. They bask on logs, rocks, and floating vegetation.
Sliders do not hibernate on land but move to a permanent water source for winter. Sliders as juveniles feed on insects, fish, small mammals, and amphibians. As adults, they become omnivorous and feed primarily on aquatic plants but still feed opportunistically on animals.
Cumberland sliders breed during winter and early spring. The females nest in open areas near wetlands. They can lay several clutches and can produce anywhere from 2 to 20 eggs per season. Males are sexually mature after 2 years; females mature after 8 years.
Slider turtles are known to live up to 40 years, but most do not live for longer than 30 years. The species has been largely affected by humans who move the turtles outside their range and release them.
The species is thought to be common in its range.
Common Musk TurtleSternotherus odoratus Common musk turtles thrive in a large range throughout the eastern United States. They are found from central Texas to the Atlantic coast. Populations are notably missing in Pennsylvania and New York, especially along mountainous regions.
The species lives in almost all freshwater habitats, from streams and rivers to reservoirs, anywhere vegetation is available. Their diverse habitats help to keep the species widespread throughout its range.
Common musk turtles are aquatic and will rarely exit water except when nesting. They do not bask in open sun as many other turtles do. Some adults grow algae on their carapaces. The turtles feed on carrion and snails along with many aquatic plants. The common name musk turtle comes from their ability to release musk when attacked or handled.
Their lifespan remains unknown, but they reach sexual maturity in approximately 3.5 years. The species is common and has no special conservation status in its range.
Photo by Scott Reasor, 2009 Photo by Brittany Petersen
A-21 Eastern Spiny Softshell TurtleApalone spinifera spinifera Eastern spiny softshell turtles range throughout Tennessee, north to New York, and as far west as the Mississippi River. There are several subspecies of the spiny softshell turtle, and the eastern spiny softshell may overlap with its fellow subspecies in their range.
The spiny softshell turtle finds its habitats in flowing water, preferably sandy-bottomed rivers that are clear and clean. They do not reside in seasonal wetlands. They are often found in farm ponds and reservoirs, and they will burrow in sandbars.
Spiny softshell turtles are aquatic and are strong swimmers. They bask on rocks and logs and will sometimes remain partly submerged in water while basking. The turtles are primarily carnivorous, eating insects, crayfish, and other aquatic animals.
The species breeds during early spring in deep water and nests from May to June. Females lay up to 18 eggs, and incubation takes up to 3 months. The sex of the hatchlings, unlike that of most turtles, is determined by genes from the parents rather than by egg temperature during incubation.
In captivity spiny softshells live up to 20 years, but in the wild their lifespan may be less. Spiny softshell turtles are abundant where they occur in their range.
A.2.3 References Conant, R., and J. T. Collins. 1998. Reptiles and AmphibiansEastern/Central North America. Houghton Mifflin Company, New York, New York.
Jensen, J. B., C. D. Camp, W. Gibbons, and M. J. Elliott. 2008. Amphibians and Reptiles of Georgia. The University of Georgia Press, Athens, Georgia.
Photo by Dr. Paul Kosnik © PKosnik@TissueGenesis.com
APPENDIX B.
DESCRIPTION OF SAMPLING METHODS
B-3 APPENDIX B. DESCRIPTION OF SAMPLING METHODS B.1 Artificial Cover Objects Cover objects are artificial material placed in a sampling location to detect any presence of reptiles or amphibians. These objects provide temporary cover for various species and, depending on the type of material, offer a microhabitat that is either moist and cool or dry and warm. The two most common types of cover objects are wooden and metal. Cover objects are set in uniform arrays. Wooden cover objects are generally arranged in a grid of 15 to 25 boards in parallel lines. This allows for a reliable index of population size and a condition of individual populations (Heyer et al. 1994).
Cover object design and placement depend on the goals and objectives of the study. Larger cover objects tend to attract a larger variety of species as well as more individuals (Heyer et al. 1994).
Average wooden cover objects are 12 x 12 x 2 in.
However, a large object may measure 48 x 48 x 2 in.
The material of wooden cover objects is typically treated plywood; however, some researchers use untreated wood to provide more moisture. This would be recommended for shorter study periods due to the relatively rapid decomposition of the cover object. Wooden cover objects are well suited for determining the presence of amphibians and anuran species. Some small mammals also use this type of cover object as nesting habitat, which provides a good prey opportunity for some snake species.
Corrugated tin is one other material commonly used for artificial cover objects. This material is used to target reptile species. Tin cover objects generally measure 48 x 24 in. They are usually arrayed in a straight line of 10 to 15 objects about 10 m apart. Placing the tin cover object along the edge between field and the forest edge will attract any individuals dispersing between the two habitats. These objects may be used through the middle sections of native warm-season grassland fields or old fields. The attraction offered by tin cover objects to reptiles is the warmth created due to their high retention of solar energy. Most reptiles can use the heat collected by the tin to regulate their own core body temperature.
This method may provide a good index of reptile populations in the study area.
Wooden cover object Tin cover object
B-4 B.2 Pitfall Traps and Drift Fence Lines Drift fence lines are designed to capture species that disperse in and out of breeding pools. There are two major methods used with drift fencing: encompassing drift fencing and straight line drift fencing. The design method of the encompassing drift fence is to completely encompass a breeding site to catch all individuals dispersing to or away from the site. The straight line drift fence is designed to be placed away from a breeding site and to capture individuals from the surrounding habitat. The method of capture used with both of these designs is pitfall traps.
Pitfall traps are buckets placed on both sides of the drift fencing 10 m apart. The buckets are placed into the ground along the edges of the drift fence. They are set in flush with the ground so that an individual easily falls into the trap. Many species will innately follow the perimeter of a barrier until they travel around the barrier, so when an individual runs into the drift fencing it will follow the edge until it is captured by a pitfall trap. This method is useful in a long-term study or in a short-term study if the trapping is carried out during the peak of the breeding season (Heyer et al. 1994).
The materials used for this method are relatively simple and inexpensive. The drift fencing is general contractor-grade silt fence. Usually the pitfall traps are made from 5 gal buckets. The drift fence may also be constructed from sheet metal. This material is much more durable in most conditions and usually can withstand a fire event. However, the sheet metal alternative is much more expensive.
B.3 Minnow Traps Minnow traps are exclusively used in aquatic environments. The target individuals are species that are fully aquatic or that use the water complex for long periods of time.
Some species have extended larval periods, or they may overwinter in water complexes. Minnow traps are designed to capture these individuals. Many of the minnow traps used are prefabricated at various companies and come ready to use. The general design of these traps is a medium or large basket made from either metal or plastic. The basket is usually 12 to 14 in.
long when fastened together and 6 to 10 in. in diameter. There are funnel-shaped openings at either end of the trap that will draw the individual into the trap. Once inside the trap, the individual cannot escape. The traps have two sides and can be separated in the middle to remove any individuals that are trapped. No bait is required with this method of trapping.
When using this method, complete coverage of an area is most effective (Heyer et al. 1994).
Pitfall trap and drift fence Minnow trap
B-5 B.4 Hoop Net Hoop nets are primarily aquatic traps, mainly used to capture turtles. Most of these nets come premanufactured. They have a very simple design. A hoop net is constructed of netting material that is stretched over three or more metal hoops that are 16 to 24 in. in diameter. These nets can be as small as 4 ft long and as large as 12 ft long. The larger traps are mainly used in lakes and larger bodies of water.
Smaller traps are set in smaller complexes such as ponds. When the trap is set, one end has a funneled opening and the other end tapers shut. This allows turtles to enter the trap but offers no escape. These traps are more effective when used with bait (usually canned meats or sardines).
B.5 Dip Net Dip-netting is an effective method for sampling the larval inhabitants of a body of water. This method uses a variety of net sizes. The smallest is typically an aquarium net 5 to 10 in. in diameter and the largest is a full size dip pole, generally 5 ft tall with a net diameter of greater than 20 in. The mesh size of the net is important. Smaller net mesh will allow for capture of very small hatchlings. The net also needs to have an effective depth so as to lessen the number of escapes (Heyer et al. 1994).
The amount of dips is variable, depending on the size of the body of water and on the vegetative cover. This method will produce a good index of population and species diversity in larval and hatchling individuals.
B.6 Visual Encounter Surveys The visual encounter survey (VES) is used to detect species presence and diversity in a certain area. The VES is measured in person-hours of search (Heyer et al. 1994).
This technique allows for an estimate of the relative abundance of species within an area. VES allows for coverage of a large area in a short time. This method is extremely effective in sampling individuals that are generally active or that use natural debris, rocks, or logs as shelter. VES is often used to survey clear-water streams with varying substrates. There are several methods in conducting VES. In forested areas with little to no ground cover, walking in a straight line and observing any ground movement, turning logs and rocks, and searching through leaf litter and other debris, can produce a good index of Hoop net Dip net Visual encounter survey
B-6 abundance. Walking in obscure patterns through the forest can also be effective. Using VES in stream surveys can be done by segmenting a stream into sections and randomly flipping submerged rocks and logs. There are some general assumptions with VES: all individuals in a given location have an equal chance of being discovered, each species has an equal chance of observation, during the study no individual is observed more than one time, and the results from two or more observers are equal (Heyer et al. 1994). The outcome of a VES is measured by comparing results with the time spent conducting it (Corn and Bury 1990). The number of personnel and time necessary depends on the size of the area.
B.7 Acoustic Monitoring Acoustic monitoring can be one of the most effective ways to sample for anuran species. It can provide an annual estimate of population size and species diversity in fixed locations. Call surveys are conducted from January to August. This time frame corresponds to the peak breeding season for most anuran species. Surveys can be conducted once a month during those months. The survey needs to be conducted at night, generally 30 min following sunset.
Acoustic surveys are best if set up in fixed locations that are part of a preselected route. The locations along the route should be representative of anuran habitat (i.e., wetland complexes, ponds, lakes, drainage areas). During the survey the observer stops at each fixed location and records any anuran vocalizations. A time frame of at least 5 min should be set at each fixed location. A method of measuring the calls can be expressed as a call index. There are three call indexes. A call index of 1 would be a single individual calling, a call index of 2 would be more than one individual calling, and a call index of 3 would be overlapping calls from one or more species. Reviewing an audio recording made during the survey can help to key out the vocalizations after the survey and catch any that were missed.
B.8 References Corn, P. S., and R. B. Bury. 1990. Sampling Methods for Terrestrial Amphibians and Reptiles.
U.S. Department of Agriculture, Forest Service. General Technical Report PNW-GTR-256.
Heyer, R. W., M. A. Donnelly, R. W. McDiarmid, L. C. Hayek, and M. S. Foster. 1994. Measuring and Monitoring Biological Diversity Standard Methods for Amphibians. Smithsonian Institution Press.
Washington, D.C.
Monitoring site
APPENDIX C.
ACOUSTIC ANURAN SURVEY DATA
C-3 APPENDIX C. ACOUSTIC ANURAN SURVEY DATA Run Information Start Finish Time (Military) 20:00 pm 6-05-08 21:20pm Wind (Beaufort Scale) 0 1
2 3
4 5
0 1
2 3
4 5
X Sky (See Code Explanations) 0 1
2 4
5 7
8 0
1 2
4 5
7 8
x
-optional-
- days since last rainfall:
3 PER STOP INFORMATION STOP #
1 2
3 4
5 6
7 8
9 10 START TIME (MILITARY)
-OPTIONAL-20:00 20:07 20:12 20:20 20:23 20:26 20:55 20:59 21:08 21:20 AIR TEMPERATURE SELECT SCALE C
F WAS NOISE A FACTOR?
(CHECK IF YES)
DID YOU TAKE A TIMEOUT? (CHECK IF YES)
SPECIES STOP 1
2 3
4 5
6 7
8 9
10 GREEN FROG 1
1 1
Run Information Start Finish Time (Military) 17:33 5-15-08 19:15 Wind (Beaufort Scale) 0 1
2 3
4 5
0 1
2 3
4 5
x Sky (See Code Explanations) 0 1
2 4
5 7
8 0
1 2
4 5
7 8
x
-optional-
- days since last rainfall:
O
C-4 Run Information Start Finish Time (Military) 9:11 5-27-09 10:39 Wind (Beaufort Scale) 0 1
2 3
4 5
0 1
2 3
4 5
x Sky (See Code Explanations) 0 1
2 4
5 7
8 0
1 2
4 5
7 8
x
-optional-
- days since last rainfall:
Same Day Run Information Start Finish Time (Military) 20:00 pm 6-05-08 21:20pm Wind (Beaufort Scale) 0 1
2 3
4 5
0 1
2 3
4 5
X Sky (See Code Explanations) 0 1
2 4
5 7
8 0
1 2
4 5
7 8
x
-optional-
- days since last rainfall:
3 Run Information Start Finish Time (Military) 9:30 6-10-09 11:45 Wind (Beaufort Scale) 0 1
2 3
4 5
0 1
2 3
4 5
x Sky (See Code Explanations) 0 1
2 4
5 7
8 0
1 2
4 5
7 8
x
-optional-
- days since last rainfall:
2
C-5 PER STOP INFORMATION STOP #
1 2
3 4
5 6
7 8
9 10 START TIME (MILITARY)
-OPTIONAL-20:00 20:07 20:12 20:20 20:23 20:26 20:55 20:59 21:08 21:20 AIR TEMPERATURE SELECT SCALE C
F WAS NOISE A FACTOR?
(CHECK IF YES)
DID YOU TAKE A TIMEOUT? (CHECK IF YES)
SPECIES STOP 1
2 3
4 5
6 7
8 9
10 GREEN FROG 1
1 1
C-6 Run Information Start Finish Time (Military) 17:33 5-15-08 19:15 Wind (Beaufort Scale) 0 1
2 3
4 5
0 1
2 3
4 5
x Sky (See Code Explanations) 0 1
2 4
5 7
8 0
1 2
4 5
7 8
x
-optional-
- days since last rainfall:
O PER STOP INFORMATION STOP #
1 2
3 4
5 6
7 8
9 10 START TIME (MILITARY)
-OPTIONAL-17:33 17:40 17:50 18:00 18:05 18:10 18:35 18:40 19:01 19:15 AIR TEMPERATURE SELECT SCALE C
F WAS NOISE A FACTOR?
(CHECK IF YES)
DID YOU TAKE A TIMEOUT? (CHECK IF YES)
SPECIES STOP 1
2 3
4 5
6 7
8 9
10 EASTERN NARROW-MOUTHED TOAD 1
1 1
Green frog 1
1 Gray treefrog 1
1 1
1 1
American toad 1
C-7 Run Information Start Finish Time (Military) 9:11 5-27-09 10:39 Wind (Beaufort Scale) 0 1
2 3
4 5
0 1
2 3
4 5
x Sky (See Code Explanations) 0 1
2 4
5 7
8 0
1 2
4 5
7 8
x
-optional-
- days since last rainfall:
Same Day PER STOP INFORMATION STOP #
1 2
3 4
5 6
7 8
9 10 START TIME (MILITARY)
-OPTIONAL-9:11 9:19 9:27 9:39 9:47 9:57 10:23 10:39 AIR TEMPERATURE 68 68 68 67 67 66 66 66 SELECT SCALE C
F WAS NOISE A FACTOR?
(CHECK IF YES)
DID YOU TAKE A TIMEOUT?
(CHECK IF YES)
SPECIES STOP #
1 2
3 4
5 6
7 8
9 10 SPRING PEEPERS 1
1 1
1 Copes gray treefrog 1
2 1
1 1
1 1
American Bullfrog 1
1 1
1 Eastern Narrow Mouthed Toad 1
1 1
Green Frog 1
2 Gray Treefrog 2
Northern Cricket Frog
C-8 Run Information Start Finish Time (Military) 9:30 6-10-09 11:45 Wind (Beaufort Scale) 0 1
2 3
4 5
0 1
2 3
4 5
x Sky (See Code Explanations) 0 1
2 4
5 7
8 0
1 2
4 5
7 8
x
-optional-
- days since last rainfall:
2 PER STOP INFORMATION STOP #
1 2
3 4
5 6
7 8
9 10 START TIME (MILITARY)
-OPTIONAL-9:30 9:38 9:46 9:59 10:09 10:32 10:44 11:01 11:18 11:38 AIR TEMPERATURE 85-78 F SELECT SCALE C
F WAS NOISE A FACTOR?
(CHECK IF YES)
DID YOU TAKE A TIMEOUT?
(CHECK IF YES)
SPECIES STOP #
1 2
3 4
5 6
7 8
9 10 COPES GRAY TREEFROG 1
2 3
1 2
Green Frog 1
1 1
1 1
1 3
2 American Bullfrog 1
1 1
1 2
2 Gray treefrog 2
1 2
2 Pickerel 1
Eastern Narrow Mouth Toad 2
Northern Cricket Frog 1
APPENDIX D.
SPECIES ABUNDANCE INVENTORY DATA
D-3 Table D.1. 2007 species abundance inventory data Date Species Scientific name Methoda Lat/ long Area 5/30 Northern dusky salamander Desmognathus fuscus fuscus VES 35.9798/ -84.2794 Walker Branch 5/30 Southern two-lined salamander Eurycea cirrigera VES 35.9798/ -84.2794 Walker Branch 5/30 Cave salamander Eurycea lucifuga VES 35.8978/ -84.3167 Copper Ridge Cave 5/31 Red-spotted newt Notophthalmus viridescens viridescens VES/DN 35.9445/ -84.3456 Hembree Marsh 6/05 Northern dusky salamander Desmognathus fuscus fuscus VES 35.9510/ -84.3262 McNew Hollow/Gum Branch 6/05 Cave salamander Eurycea lucifuga VES 35.8978/ -84.3167 Copper Ridge Cave 6/06 Red-spotted newt Notophthalmus viridescens viridescens VES/DN 35.9445/ -84.3456 Hembree Marsh 6/06 Southern leopard frog Rana utricularia VES 35.9445/ -84.3456 Hembree Marsh 6/08 Eastern box turtle Terrapene carolina Carolina VES 35.9718/ -84.3014 Pine Ridge 6/08 Northern ringneck snake Diadophis punctatus edwardsii VES 35.9718/ -84.3014 Pine Ridge 6/08 Northern red salamander Pseudotriton ruber ruber VES 35.9718/ -84.3014 Pine Ridge 6/08 Northern dusky salamander Desmognathus fuscus fuscus VES 35.9718/ -84.3014 Pine Ridge 6/08 Southern two-lined salamander Eurycea cirrigera VES 35.9718/ -84.3014 Pine Ridge 6/12 Northern dusky salamander Desmognathus fuscus fuscus VES 35.9640/ -84.3490 Mesophytic Forest 6/13 Northern dusky salamander Desmognathus fuscus fuscus VES 35.9357/ -84.2847 Bearden Creek 6/13 Northern two-lined salamander Eurycea cirrigera VES 35.9357/ -84.2847 Bearden Creek 6/13 Southern leopard frog Rana utricularia VES 35.9357/ -84.2847 Bearden Creek 6/13 Green frog Rana clamitans melanota VES 35.9357/ -84.2847 Bearden Creek 6/14 Northern dusky salamander Desmognathus fuscus fuscus VES 35.9357/ -84.2847 Bearden Creek 6/14 Pickerel frog Rana palustris VES 35.9357/ -84.2847 Bearden Creek 6/14 Southern two-lined salamander Eurycea cirrigera VES 35.9357/ -84.2847 Bearden Creek 6/14 American toad Bufo americanus VES 35.9357/ -84.2847 Bearden Creek 6/14 Green frog Rana clamitans melanota VES 35.9357/ -84.2847 Bearden Creek 6/20 Eastern box turtle Terrapene carolina carolina VES 35.9510/ -84.3262 McNew Hollow/Gum Branch 6/20 Northern dusky salamander Desmognathus fuscus fuscus VES 35.9510/ -84.3262 McNew Hollow/Gum Branch 6/20 Northern red salamander Pseudotriton ruber ruber VES 35.9510/ -84.3262 McNew Hollow/Gum Branch 6/20 Northern dusky salamander Desmognathus fuscus fuscus VES 35.9357/ -84.2847 Bearden Creek 6/20 Long-tailed salamander Eurycea longicauda longicauda VES 35.9357/ -84.2847 Bearden Creek 6/26 Southern two-lined salamander Eurycea cirrigera VES 35.9415/ -84.2745 Near Shepards Cemetery
D-4 Table D.1 (continued)
Date Species Scientific name Methoda Lat/ long Area 7/02 Cave salamander Eurycea lucifuga VES 35.8978/ -84.3167 Copper Ridge Cave 7/02 Northern slimy salamander Plethodon glutinosis complex VES 35.8978/ -84.3167 Copper Ridge Cave 7/10 Northern watersnake Nerodia sipedon sipedon VES 35.9357/ -84.2847 Bearden Creek 7/10 Eastern worm snake Carphophis amoenus amoenus VES 35.9357/ -84.2847 Bearden Creek 7/10 Long-tailed salamander Eurycea longicauda longicauda VES 35.9357/ -84.2847 Bearden Creek 7/10 Southern two-lined salamander Eurycea cirrigera VES 35.9357/ -84.2847 Bearden Creek 7/10 Green frog Rana clamitans melanota VES 35.9357/ -84.2847 Bearden Creek 7/10 Northern ringneck snake Diadophis punctatus edwardsii VES 35.9357/ -84.2847 Bearden Creek 7/10 Northern dusky salamander Desmognathus fuscus fuscus VES 35.9357/ -84.2847 Bearden Creek 7/10 Eastern box turtle Terrapene carolina carolina VES 35.9357/ -84.2847 Bearden Creek 7/10 Northern red salamander Pseudotriton ruber ruber VES 35.9357/ -84.2847 Bearden Creek 7/12 Northern dusky salamander Desmognathus fuscus fuscus VES 35.9798/ -84.2794 Walker Branch 7/12 Eastern box turtle Terrapene carolina carolina VES 35.9798/ -84.2794 Walker Branch 7/27 Green frog Rana clamitans melanota VES 35.8978/ -84.3167 Copper Ridge Cave 7/27 Northern slimy salamander Plethodon glutinosis complex VES 35.8978/ -84.3167 Copper Ridge Cave 7/27 Cave salamander Eurycea lucifuga VES 35.8978/ -84.3167 Copper Ridge Cave 7/27 Northern red salamander Pseudotriton ruber ruber VES 35.8978/ -84.3167 Copper Ridge Cave aAbbreviations:
DN: dip net VES: visual encounter survey
D-5 Table D-2. 2008 species abundance inventory dataa Date Time Species Scientific Name Length Wt.
Methoda Lat./ Long Area Total SVL 5/22 10:00AM Red-spotted newt Notophthalmus viridescens viridescens 108.4 48.55 4.5 MT 35.9445/ -84.3456 Hembree Marsh 5/22 10:00AM Red-spotted newt Notophthalmus viridescens viridescens 106.4 54.78 5.9 MT 35.9445/ -84.3456 Hembree Marsh 5/22 10:00AM Red-spotted newt Notophthalmus viridescens viridescens 81.4 37.3 2.9 MT 35.9445/ -84.3456 Hembree Marsh 5/22 10:00AM Red-spotted newt Notophthalmus viridescens viridescens 109.999 52.35 5.9 MT 35.9445/ -84.3456 Hembree Marsh 5/22 10:00AM Red-spotted newt Notophthalmus viridescens viridescens 111.1 51.5 5.2 MT 35.9445/ -84.3456 Hembree Marsh 5/22 10:00AM Red-spotted newt Notophthalmus viridescens viridescens 93.9 47.1 1.85 MT 35.9445/ -84.3456 Hembree Marsh 5/22 10:00AM Red-spotted newt Notophthalmus viridescens viridescens 81.5 38.85 2.1 MT 35.9445/ -84.3456 Hembree Marsh 5/22 10:00AM Red-spotted newt Notophthalmus viridescens viridescens MT 35.9445/ -84.3456 Hembree Marsh 5/22 10:00AM N. dusky salamander Desmognathus fuscus fuscus 123.6 38.85 8.2 MT 35.9445/ -84.3456 Hembree Marsh 5/22 10:00AM Marbled salamander (larval)
Ambystoma opacum 51.1 25.8 1
MT 35.9445/ -84.3456 Hembree Marsh 5/22 10:00AM Marbled salamander (larval)
Ambystoma opacum 53.4 29.999 1.1 MT 35.9445/ -84.3456 Hembree Marsh 5/22 10:00AM Marbled salamander (larval)
Ambystoma opacum 51.8 26.7 1.1 MT 35.9445/ -84.3456 Hembree Marsh 5/22 10:00AM Marbled salamander (larval)
Ambystoma opacum 53.3 29.4 1
MT 35.9445/ -84.3456 Hembree Marsh 5/22 10:00AM Marbled salamander (larval)
Ambystoma opacum 70.21 42 2.9 MT 35.9445/ -84.3456 Hembree Marsh 5/22 10:00AM Marbled salamander (larval)
Ambystoma opacum 47.9 28.2 0.9 MT 35.9445/ -84.3456 Hembree Marsh 5/22 10:00AM Marbled salamander (larval)
Ambystoma opacum 52.8 25.1 0.9 MT 35.9445/ -84.3456 Hembree Marsh 5/22 10:00AM Marbled salamander (larval)
Ambystoma opacum 46.7 27.8 0.9 MT 35.9445/ -84.3456 Hembree Marsh 5/22 10:00AM Marbled salamander (larval)
Ambystoma opacum 57.2 29.3 1.2 MT 35.9445/ -84.3456 Hembree Marsh
D-6 Table D-2 (continued)
Date Time Species Scientific Name Length Wt.
Methoda Lat./ Long Area Total SVL 5/22 10:00AM Marbled salamander (larval)
Ambystoma opacum 35.9445/ -84.3456 Hembree Marsh 5/22 10:00AM Pickerel frog Rana palustris 35 VES 35.9445/ -84.3456 Hembree Marsh 5/22 2:14PM Southern leopard frog Rana utricularia 61.8 11.2 VES 35.9537/-84.2847 Bearden Creek 5/22 2:14PM Southern leopard frog Rana utricularia 39.4 4
VES 35.9537/-84.2847 Bearden Creek 5/22 2:25PM Northern dusky salamander Desmognathus fuscus fuscus 111.2 119 7.2 VES 35.9537/-84.2847 Bearden Creek 5/22 2:49PM Northern dusky salamander Desmognathus fuscus fuscus 65.2 39.6 3.5 VES 35.9537/-84.2847 Bearden Creek 5/22 2:53PM Northern dusky salamander Desmognathus fuscus fuscus 90.97 47.4 3.8 VES 35.9537/-84.2847 Bearden Creek 5/22 2:57PM Southern leopard frog Rana utricularia 45.2 7.2 VES 35.9537/-84.2847 Bearden Creek 5/22 2:57PM Southern two-lined salamander Eurycea cirrigera 90.5 43.9 1
VES 35.9537/-84.2847 Bearden Creek 5/22 2:57PM Northern dusky salamander Desmognathus fuscus fuscus 32.9 16.7 N/A VES 35.9537/-84.2847 Bearden Creek 5/22 4:44PM Eastern american toad Bufo americanus americanus 65.3 42 VES 35.954018 /
84.382447 Rainy Knob 5/22 4:44PM Cave salamander Eurycea lucifuga 145.2 62.5 4.8 VES 35.954018 /
84.382447 Rainy Knob 5/23 10:45AM Marbled salamander (larval)
Ambystoma opacum 51 27.1 1
MT 35.9445/ -84.3456 Hembree Marsh 5/23 10:45AM Marbled salamander (larval)
Ambystoma opacum 55.4 31.1 1
MT 35.9445/ -84.3456 Hembree Marsh 5/23 10:45AM Marbled salamander (larval)
Ambystoma opacum 54.99 30.3 1.1 MT 35.9445/ -84.3456 Hembree Marsh 5/23 10:45AM Marbled salamander (larval)
Ambystoma opacum 53.3 27.4 0.8 MT 35.9445/ -84.3456 Hembree Marsh 5/23 10:45AM Marbled salamander (larval)
Ambystoma opacum 48.7 28.2 0.8 MT 35.9445/ -84.3456 Hembree Marsh
D-7 Table D-2 (continued)
Date Time Species Scientific Name Length Wt.
Methoda Lat./ Long Area Total SVL 5/23 10:45AM Marbled salamander (larval)
Ambystoma opacum 47.1 26.3 1
MT 35.9445/ -84.3456 Hembree Marsh 5/23 10:45AM Red-spotted newt Notophthalmus viridescens viridescens 103.2 48 5.1 MT 35.9445/ -84.3456 Hembree Marsh 5/23 10:45AM Red-spotted newt Notophthalmus viridescens viridescens 84.2 32.5 2.9 MT 35.9445/ -84.3456 Hembree Marsh 5/23 10:00AM Five-lined skink Eumeces fasciatus 75.9 45.9 1.2 PF 35.9445/ -84.3456 Hembree Marsh 5/23 3:30PM Southeastern five-lined skink Eumeces inexpectatus
> 153.0 65.2 9.8 CO 35.983360 /
84.199164 Solway Bend 5/23 3:30PM Northern brown snake Storeria dekayi dekayi
> 153.0 153.0 10 CO 35.983360 /
84.199164 Solway Bend 5/23 3:30PM Northern brown snake Storeria dekayi dekayi
> 153.0 153.0 5.2 CO 35.983360 /
84.199164 Solway Bend 5/27 10:00AM Smooth earth snake Virginia valerie
> 153.0 153.0 4
CO 35.983360 /
84.199164 Solway Bend 5/27 10:00AM Smooth earth snake Virginia valerie
> 153.0 153.0 110.
3 CO 35.983360 /
84.199164 Solway Bend 5/27 10:00AM Northern brown snake Storeria dekayi dekayi
> 153.0 153.0 5
CO 35.983360 /
84.199164 Solway Bend 5/27 10:00AM Northern brown snake Storeria dekayi dekayi
> 153.0 153.0 5.2 CO 35.983360 /
84.199164 Solway Bend 5/28 4:57PM Cumberland slider Trachemys scripta troostii 280 240 0
HN 35.922398 /
84.321439 Carp Pond 1
5/29 11:00AM Painted turtle Chrysemys picta 135 260 HN 35.543073 /
84.231976 Thigh High Pond 5/29 11:00AM Painted turtle Chrysemys picta 145 275 HN 35.543073 /
84.231976 Thigh High Pond 5/29 11:00AM Cumberland slider Trachemys scripta troostii 220 920 HN 35.543073 /
84.231976 Thigh High Pond 5/29 11:00AM Cumberland slider Trachemys scripta troostii 240 150 0
HN 35.543073 /
84.231976 Thigh High Pond 5/29 11:30AM Marbled salamander Ambystoma opacum 51.4 27.9 3
PF 35.9445/ -84.3463 Hembree Marsh 5/30 12:00PM Eastern box turtle Terrapene carolina 68.5 70 VES Rte. 95 North
D-8 Table D-2 (continued)
Date Time Species Scientific Name Length Wt.
Methoda Lat./ Long Area Total SVL 5/30 1:00PM Eastern box turtle Terrapene carolina 124.9 415 VES 35.9510 / -84.3262 McNew Hollow Road 5/30 2:20PM Northern watersnake Nerodia sipedon sipedon 640 630 85 VES 35.9640/ -84.3490 Mesophytic Forest 5/30 2:20PM Northern ringneck snake Diadophis punctatus edwardsii 122 107.7 1.2 VES 35.9640/ -84.3490 Mesophytic Forest 5/30 2:20PM Northern dusky salamander Desmognathus fuscus fuscus 32.9 16.6 0.2 VES 35.9640/ -84.3490 Mesophytic Forest 5/30 2:20PM Northern dusky salamander Desmognathus fuscus fuscus 37.7 19.5 0.2 VES 35.9640/ -84.3490 Mesophytic Forest 5/30 2:20PM Northern dusky salamander Desmognathus fuscus fuscus 33.6 16.6 0.2 VES 35.9640/ -84.3490 Mesophytic Forest 5/30 2:20PM Spotted salamander (larval)
Ambystoma maculatum 34.7 20.5 0.6 VES 35.9640/ -84.3490 Mesophytic Forest 5/30 2:20PM Spotted salamander (larval)
Ambystoma maculatum 34.1 23.3 0.2 VES 35.9640/ -84.3490 Mesophytic Forest 5/30 2:20PM Spotted salamander (larval)
Ambystoma maculatum 29.2 17.5 0.2 VES 35.9640/ -84.3490 Mesophytic Forest 5/30 2:20PM Spotted salamander (larval)
Ambystoma maculatum 36.1 21.6 0.2 VES 35.9640/ -84.3490 Mesophytic Forest 6/3 10:30AM Northern dusky salamander Desmognathus fuscus fuscus 76.1 30.3 1.2 VES 35.9537/-84.2847 Bearden Creek 6/3 10:30AM Northern dusky salamander Desmognathus fuscus fuscus 92.35 43.8 2.8 VES 35.9537/-84.2847 Bearden Creek 6/3 10:30AM Northern dusky salamander Desmognathus fuscus fuscus 50.08 24.4 0.8 VES 35.9537/-84.2847 Bearden Creek 6/3 2:30PM Snapping turtle Chelydra serpentina 304.8 3628 HN 35.980686 /
84.211110 Solway Bend Ponds 6/3 2:30PM Painted turtle Chrysemys picta 170 360 HN 35.980686 /
84.211110 Solway Bend Ponds 6/3 2:30PM Cumberland slider Trachemys scripta troostii 210 650 HN 35.980686 /
84.211110 Solway Bend Ponds
D-9 Table D-2 (continued)
Date Time Species Scientific Name Length Wt.
Methoda Lat./ Long Area Total SVL 6/3 2:30PM Painted turtle Chrysemys picta 125 165 HN 35.980686 /
84.211110 Solway Bend Ponds 6/3 2:30PM Painted turtle Chrysemys picta 125 370 HN 35.980686 /
84.211110 Solway Bend Ponds 6/3 2:30PM Common musk turtle Sternotherus odoratus 135 175 HN 35.980686 /
84.211110 Solway Bend Ponds 6/3 2:30PM Painted turtle Chrysemys picta 175 410 HN 35.980686 /
84.211110 Solway Bend Ponds 6/3 2:30PM Painted turtle Chrysemys picta 175 380 HN 35.980686 /
84.211110 Solway Bend Ponds 6/3 2:30PM Cumberland slider Trachemys scripta troostii 230 1220 HN 35.980686 /
84.211110 Solway Bend Ponds 6/4 4:35PM Northern red salamander Pseudotriton ruber ruber 93.7 55.2 3
DN 35.954018 /
84.382447 Black Oak/
Amphibian Site 5 6/4 4:35PM Southern two-lined salamander Eurycea cirrigera 52.8 27.4 0.8 DN 35.954018 /
84.382447 Black Oak/
Amphibian Site 5 6/4 4:35PM Southern two-lined salamander Eurycea cirrigera 44.9 22.8 0.4 DN 35.954018 /
84.382447 Black Oak/
Amphibian Site 5 6/4 4:35PM Southern two-lined salamander Eurycea cirrigera 38.9 22.6 0.6 35.954018 /
84.382447 Black Oak/
Amphibian Site 5 6/5 7:49 PM Black kingsnake Lampropeltis getula nigra 80 73 150 CO 35.983360 /
84.199164 Solway Bend 6/6 2:39PM Eastern spiny softshell Apalone spinifera spinifera VES Clark Center Park 6/6 2:00PM Eastern narrow-mouthed toad Gastrophryne carolinensis VES 35.983360 /
84.199164 Solway Bend
D-10 Table D-2 (continued)
Date Time Species Scientific Name Length Wt.
Methoda Lat./ Long Area Total SVL 6/9 10:00AM Eastern box turtle Terrapene carolina 123.6 407 VES 35.980686 /
84.211110 Freels Bend 6/9 5:33PM Cumberland slider Trachemys scripta troostii 191 630 HN 35.954018 /
84.382447 Black Oak/
Amphibian Site 5 6/17 11:00AM Pickerel frog Rana palustris 26.41 1.2 MT 35.961221 /
84.256830 NWSG site 2
6/17 11:00AM Pickerel frog Rana palustris 29.65 1.5 MT 35.961221 /
84.256830 NWSG site 3
6/17 12:00PM Southern two-lined salamander Eurycea cirrigera 81.15 36.41 1
CO 35.9537/-84.2847 Bearden Creek 6/17 12:00PM Northern red salamander Pseudotriton ruber ruber 65.05 37.4 0.09 VES 35.9537/-84.2847 Bearden Creek 6/17 12:00PM Spotted dusky salamander Desmognathus fuscus conanti 129.11 63.1 8
VES 35.9537/-84.2847 Bearden Creek 6/18 10:30AM Pickerel frog Rana palustris 27.3 0.85 MT 35.961221 /
84.256830 NWSG site 2
6/18 10:30AM Pickerel frog Rana palustris 25.2 0.6 MT 35.961221 /
84.256831 NWSG site 3
6/30 2:16PM Northern brown snake Storeria dekayi dekayi 180 140 2.6 CO 35.983360 /
84.199164 Solway Bend 6/30 2:16PM Northern brown snake Storeria dekayi dekayi 225 174 4
CO 35.983360 /
84.199164 Solway Bend 6/30 2:16PM Northern brown snake Storeria dekayi dekayi 240 200 6.2 CO 35.983360 /
84.199164 Solway Bend 6/30 2:16PM Smooth earth snake Virginia valerie 190 154.6 4.4 CO 35.983360 /
84.199164 Solway Bend 7/1 3:30PM Southern two-lined salamander Eurycea cirrigera 84.1 45.8 1.4 VES 35.9640/ -84.3490 Mesophytic Forest 7/1 3:30PM Southern two-lined salamander Eurycea cirrigera 40.1 23.4 0.4 VES 35.9640/ -84.3490 Mesophytic Forest 7/1 3:30PM Spotted dusky salamander Desmognathus conanti 108 51.5 4.4 VES 35.9640/ -84.3490 Mesophytic Forest 7/1 3:30PM Spotted dusky salamander Desmognathus conanti 75.6 36.9 1.2 VES 35.9640/ -84.3490 Mesophytic Forest 7/1 3:30PM Spotted dusky salamander Desmognathus conanti 102.2 55.3 4.1 VES 35.9640/ -84.3490 Mesophytic Forest
D-11 Table D-2 (continued)
Date Time Species Scientific Name Length Wt.
Methoda Lat./ Long Area Total SVL 7/2 11:30AM Northern brown snake Storeria dekayi dekayi 260 220 7.1 CO 35.983360/84.199164 Solway Bend 7/2 11:30AM Northern brown snake Storeria dekayi dekayi 220 169 3.9 CO 35.983360/84.199164 Solway Bend 7/2 11:30AM Southeastern five-lined skink Eumeces inexpectatus 121.1 61.75 6.1 CO 35.983360/84.199164 Solway Bend 7/2 3:06PM Spotted dusky salamander Desmognathus conanti 128.2 65.4 7.4 VES 35.9537/-84.2847 Bearden Creek 7/2 3:23PM Spotted dusky salamander Desmognathus conanti 95.1 52.5 5
VES 35.9537/-84.2847 Bearden Creek 7/2 3:23PM Spotted dusky salamander Desmognathus conanti 85 38.6 2.2 VES 35.9537/-84.2847 Bearden Creek 7/2 3:30PM Southern two-lined salamander Eurycea cirrigera 51.3 23 0.2 VES 35.9537/-84.2847 Bearden Creek 7/3 11:30AM Red-bellied snake Storeria occipitomaculata 295 230 2.8 PF 35.9445/-84.3456 Hembree Marsh 7/7 10:30AM Northern copperhead Agkistrodon contortrix mokasen Freels Bend 7/14 10:00AM Spotted dusky salamander Desmognathus conanti 39.3 19.4 1.1 VES 35.9537/-84.2847 Bearden Creek 7/14 10:00AM Spotted dusky salamander Desmognathus conanti 27.3 13.5 0.8 VES 35.9537/-84.2847 Bearden Creek 7/14 10:00AM Spotted dusky salamander Desmognathus conanti 85.9 41.3 4.1 VES 35.9537/-84.2847 Bearden Creek 7/14 10:00AM Spotted dusky salamander Desmognathus conanti 28.1 19.9 0.5 VES 35.9537/-84.2847 Bearden Creek 7/14 10:00AM Northern dusky salamander Desmognathus fuscus fuscus 98.1 54.3 4
VES 35.9537/-84.2847 Bearden Creek
D-12 Table D-2 (continued)
Date Time Species Scientific Name Length Wt.
Methoda Lat./ Long Area Total SVL 7/14 10:00AM Northern dusky salamander Desmognathus fuscus fuscus 91.8 54.3 4
VES 35.9537/-84.2847 Bearden Creek 7/14 10:00AM Northern dusky salamander Desmognathus fuscus fuscus 89.8 44.8 3.8 VES 35.9537/-84.2847 Bearden Creek 7/14 10:00AM Northern dusky salamander Desmognathus fuscus fuscus 41.7 20.8 2.1 VES 35.9537/-84.2847 Bearden Creek aAbbrevations:
CO: cover object DN: dip net HN: hoop net MT minnow trap PF: pitfall trap SVL: snout-to-vent length VES: visual encounter survey
D-13 Table D-3. 2009 species abundance inventory data Date Time Species Scientific name Total SVL Wt.
Methoda Lat./Long.
Area 5/11/2009 9:00AM Northern water snake Nerodia sipedon sipedon
>153
>153 VES 35.9798/-84.2794 Walker Branch 5/14/2009 2:30PM Two lined salamander Eurycea cirrigera 81.7 35.2 1.15 VES 35.9537/-84.2847 Bearden Creek 5/14/2009 2:30PM Two lined salamander Eurycea cirrigera 77.2 35.7 1.99 VES 35.9537/-84.2847 Bearden Creek 5/14/2009 3:00PM Spotted dusky D. fuscus conanti 46.4 22.1 1.2 VES 35.9537/-84.2847 Bearden Creek 5/15/2009 11:00AM Spotted dusky D. fuscus conanti 75 32.2 1.5 VES Clear Spring Road 5/15/2009 11:30AM Spotted dusky D. fuscus conanti 25.3 15.5 0.85 VES Clear Spring Road 5/20/2009 9:30AM Five-lined skink Eumeces fasciatus 93.4 40.2 1.8 CB 35.980686 / 84.211110 Solway/ Lynard Skynard pond 5/20/2009 9:30AM N. brown snake Storeria dekayi dekayi
>153
>153 7.4 CB 35.980686 / 84.211110 Solway/ Lynard Skynard pond 5/20/2009 10:00AM Black rat snake Elaphe obsoleta
>153
>153 90 TIN 35.983360 / 84.199164 Solway Bend 5/20/2009 10:00AM Ringneck snake Diadophis punctatus edwardsii
>153
>153 11 CB 35.983360 / 84.199164 Solway Bend 5/20/2009 10:00AM Five-lined skink Eumeces fasciatus 124.2 64.5 7.2 VES 35.983360 / 84.199164 Solway Bend 5/21/2009 10:30AM Northern water snake Nerodia sipedon sipedon 1346.2 1066.8 845 VES Bethel Valley Road 5/22/2009 11:00AM Desmognathus VES 35.954018 / 84.382447 Amphibian Site 5 5/26/2009 12:30PM Spiny softshell turtle Apalone spinifera spinifera VES Fishing Area near Solway 5/26/2009 3:00PM Northern water snake Nerodia sipedon sipedon VES Fishing Area near Solway 6/3/2009 1:00PM Spotted dusky D. fuscus conanti 91.8 46.3 4.3 VES 35.9640/ -84.3490 Mesophytic Forest 6/3/2009 1:00PM Two lined salamander Eurycea cirrigera 47.8 19.2 1
VES 35.9640/ -84.3490 Mesophytic Forest 6/3/2009 1:00PM Spotted dusky D. fuscus conanti 31.5 19.2 1.5 VES 35.9640/ -84.3490 Mesophytic Forest 6/3/2009 1:00PM Spotted dusky D. fuscus conanti 37.5 17.7 1.7 VES 35.9640/ -84.3490 Mesophytic Forest 6/3/2009 1:00PM Spotted dusky D. fuscus conanti 36.3 18.3 1.9 VES 35.9640/ -84.3490 Mesophytic Forest 6/4/2009 2:30PM Northern red salamander Pseudotriton ruber ruber 72.3 37.8 1.1 VES 35.9640/ -84.3490 North HW Cove/Natural Area 6/4/2009 2:30PM Northern dusky D. fuscus fuscus 62.3 31.3 1.2 VES 35.9640/ -84.3490 North HW Cove/Natural Area 6/4/2009 2:30PM Northern dusky D. fuscus fuscus 50.5 27.4 1
VES 35.9640/ -84.3490 North HW Cove/Natural Area 6/4/2009 2:30PM Eurycea 36.6 20.7 0.2 VES 35.9640/ -84.3490 North HW Cove/Natural Area 6/4/2009 3:40PM Black racer Coluber constrictor 1066.8 888.6 220 VES Bear Creek Road 6/5/2009 3:00PM Cumberland slider Trachemys scripta troostii VES Generator Ponds 6/5/2009 3:15PM Ringneck snake Diadophis punctatus edwardsii 153.9 137.8 1.3 CB 35.983360 / 84.199164 Solway Bend 6/5/2009 3:30PM Eastern box turtle Terrapene carolina 122.3 355 VES 36.042956/-84.238514 Bethel Valley Road 6/8/2009 12:30PM Black rat snake Elaphe obsoleta 628.6 520.7 80 TIN 35.961221 / 84.256830 NWSG site 6/17/2009 12:00PM Red-spotted newt N. viridescens viridescens 93.8 48.8 3.8 MT 35.9445/ -84.3456 Hembree Marsh 6/17/2009 12:00PM Marbled/ larval Ambystoma opacum 43.5 25.2 1
MT 35.9445/ -84.3456 Hembree Marsh 6/17/2009 12:00PM Marbled/ larval Ambystoma opacum 44.2 22.9 0.9 MT 35.9445/ -84.3456 Hembree Marsh 6/17/2009 12:00PM Marbled/ larval Ambystoma opacum 43.2 22.7 1
MT 35.9445/ -84.3456 Hembree Marsh 6/17/2009 12:00PM Marbled/ larval Ambystoma opacum 52.6 27.2 1.2 MT 35.9445/ -84.3456 Hembree Marsh 6/17/2009 12:00PM Marbled/ larval Ambystoma opacum 47.1 27.2 1.1 MT 35.9445/ -84.3456 Hembree Marsh 6/17/2009 12:00PM Marbled/ larval Ambystoma opacum 41.4 20.2 1.1 MT 35.9445/ -84.3456 Hembree Marsh 6/17/2009 12:00PM Marbled/ larval Ambystoma opacum 39.1 24.1 1
MT 35.9445/ -84.3456 Hembree Marsh 6/17/2009 12:00PM Marbled/ larval Ambystoma opacum 46 25.2 1.1 MT 35.9445/ -84.3456 Hembree Marsh 6/17/2009 3:00PM Spotted dusky D. fuscus conanti 101 49.1 3.9 VES 35.9640/ -84.3490 North HW Cove/Natural Area 6/17/2009 3:00PM Spotted dusky D. fuscus conanti 73.6 32 1.2 VES 35.9640/ -84.3490 North HW Cove/Natural Area 6/17/2009 3:00PM Spotted dusky D. fuscus conanti 32.4 17.1 0.1 VES 35.9640/ -84.3490 North HW Cove/Natural Area 6/17/2009 3:00PM Northern dusky D. fuscus fuscus 32 17.6 1.2 VES 35.9640/ -84.3490 North HW Cove/Natural Area
D-14 Table D-3 (continued)
Date Time Species Scientific name Total SVL Wt.
Methoda Lat./Long.
Area 6/17/2009 3:00PM Spotted dusky D. fuscus conanti 40.8 21 0.4 VES 35.9640/ -84.3490 North HW Cove/Natural Area 6/17/2009 3:00PM Spotted dusky D. fuscus conanti 38.7 19.4 0.4 VES 35.9640/ -84.3490 North HW Cove/Natural Area 6/17/2009 3:00PM Northern red salamander Pseudotriton ruber ruber 85.6 48.6 2.25 VES 35.9640/ -84.3490 North HW Cove/Natural Area 6/17/2009 12:00PM Red-spotted newt N. viridescens viridescens 89.4 43.1 3.1 MT 35.9445/ -84.3456 Hembree Marsh 6/17/2009 12:00PM Red-spotted newt N. viridescens viridescens 97.35 45.9 3.2 MT 35.9445/ -84.3456 Hembree Marsh 6/17/2009 12:00PM Red-spotted newt N. viridescens viridescens 82.99 43 3.1 MT 35.9445/ -84.3456 Hembree Marsh 6/17/2009 12:00PM Red-spotted newt N. viridescens viridescens 101.2 49.5 4.1 MT 35.9445/ -84.3456 Hembree Marsh 6/17/2009 3:00PM Northern dusky D. fuscus fuscus 34.9 17.6 0.1 VES 35.9640/ -84.3490 North HW Cove/Natural Area 6/17/2009 3:00PM Northern dusky D. fuscus fuscus 38.5 18.7 0.8 VES 35.9640/ -84.3490 North HW Cove/Natural Area 6/17/2009 3:00PM Northern dusky D. fuscus fuscus 33.9 14.8 0.15 VES 35.9640/ -84.3490 North HW Cove/Natural Area 6/17/2009 3:00PM Desmognathus 38.6 20.9 0.1 VES 35.9640/ -84.3490 North HW Cove/Natural Area 6/17/2009 3:00PM Spotted dusky D. fuscus conanti 37 15.4 0.5 VES 35.9640/ -84.3490 North HW Cove/Natural Area 6/17/2009 3:00PM Desmognathus 31.5 18.2 0.2 VES 35.9640/ -84.3490 North HW Cove/Natural Area 6/17/2009 4:00PM Northern water snake Nerodia sipedon sipedon 1371.6 VES Bethel Valley Road 6/19/2009 11:30 AM Ringneck snake Diadophis punctatus edwardsii 177.8 152.4 2.4 CB 35.983360 / 84.199164 Solway Bend 6/19/2009 2:00 PM Northern dusky D. fuscus fuscus 22.6 12.8 0.15 VES 35.981746/ 84.275870 ESD Stream 6/19/2009 2:00 PM Northern dusky D. fuscus fuscus 25 14.7 0.4 VES 35.981746/ 84.275870 ESD Stream 6/19/2009 2:00 PM Desmognathus 15.9 9.7 0.2 VES 35.981746/ 84.275870 ESD Stream 6/19/2009 2:00 PM Desmognathus 32.5 15.8 0.1 VES 35.981746/ 84.275870 ESD Stream 6/19/2009 2:00 PM Desmognathus 37.9 20.3 0.6 VES 35.981746/ 84.275870 ESD Stream 6/19/2009 2:00 PM Desmognathus 30 13.4 0.2 VES 35.981746/ 84.275870 ESD Stream 6/19/2009 4:00 PM Eurycea 36.3 17.5 0.1 VES 35.954018 / 84.382447 Amphibian Site 5 6/19/2009 4:00 PM Desmognathus 38 20.3 0.2 VES 35.954018 / 84.382447 Amphibian Site 5 6/19/2009 4:00 PM Eurycea 42.1 18.8 0.8 VES 35.954018 / 84.382447 Amphibian Site 5 6/19/2009 4:00 PM Eurycea 35.2 16.9 0.6 VES 35.954018 / 84.382447 Amphibian Site 5 6/19/2009 4:00 PM Northern two lined salamander Eurycea cirrigera 42.2 18.4 0.8 VES 35.954018 / 84.382447 Amphibian Site 5 6/23/2009 12:00 PM Marbled/ larval Ambystoma opacum 46.2 27.3 0.8 MT 35.9445/ -84.3456 Hembree Marsh 6/23/2009 12:00 PM Marbled/ larval Ambystoma opacum 47.4 28.2 0.6 MT 35.9445/ -84.3456 Hembree Marsh 6/23/2009 12:00 PM Marbled/ larval Ambystoma opacum 53.5 29.4 0.8 MT 35.9445/ -84.3456 Hembree Marsh 6/23/2009 12:00 PM Marbled/ larval Ambystoma opacum 43.3 25.8 0.6 MT 35.9445/ -84.3456 Hembree Marsh 6/23/2009 12:00 PM Marbled/ larval Ambystoma opacum 43.6 23.4 0.7 MT 35.9445/ -84.3456 Hembree Marsh 6/23/2009 12:00 PM Marbled/ larval Ambystoma opacum 47.1 23.2 1
MT 35.9445/ -84.3456 Hembree Marsh 6/23/2009 12:00 PM Marbled/ larval Ambystoma opacum 45.1 25.1 0.9 MT 35.9445/ -84.3456 Hembree Marsh 6/23/2009 12:00 PM Marbled/ larval Ambystoma opacum 45.2 24.9 1
MT 35.9445/ -84.3456 Hembree Marsh 6/23/2009 12:00 PM Marbled/ larval Ambystoma opacum 50.03 26.8 0.7 MT 35.9445/ -84.3456 Hembree Marsh 6/23/2009 12:00 PM Marbled/ larval Ambystoma opacum 40.04 26.4 1.1 MT 35.9445/ -84.3456 Hembree Marsh 6/23/2009 12:00 PM Marbled/ larval Ambystoma opacum 39.9 20.08 1
MT 35.9445/ -84.3456 Hembree Marsh 6/23/2009 12:00 PM Marbled/ larval Ambystoma opacum 50.01 25.6 1.1 MT 35.9445/ -84.3456 Hembree Marsh 6/23/2009 12:00 PM Marbled/ larval Ambystoma opacum 50 27.6 1.2 MT 35.9445/ -84.3456 Hembree Marsh 6/23/2009 12:00 PM Marbled/ larval Ambystoma opacum 45.7 22.6 1.2 MT 35.9445/ -84.3456 Hembree Marsh 6/23/2009 12:00 PM Marbled/ larval Ambystoma opacum 51.6 22.7 1.3 MT 35.9445/ -84.3456 Hembree Marsh 6/23/2009 12:00 PM Marbled/ larval Ambystoma opacum 48.2 24.1 1.4 MT 35.9445/ -84.3456 Hembree Marsh 6/23/2009 12:00 PM Red-spotted newt N. viridescens viridescens 103.5 45.6 5.2 MT 35.9445/ -84.3456 Hembree Marsh 6/23/2009 12:00 PM Red-spotted newt N. viridescens viridescens 86.2 40.8 3.4 MT 35.9445/ -84.3456 Hembree Marsh 6/23/2009 12:00 PM Red-spotted newt N. viridescens viridescens 103.3 53.6 7.6 MT 35.9445/ -84.3456 Hembree Marsh
D-15 Table D-3 (continued)
Date Time Species Scientific name Total SVL Wt.
Methoda Lat./Long.
Area 6/23/2009 12:00 PM Red-spotted newt N. viridescens viridescens 88.6 48.8 5.6 MT 35.9445/ -84.3456 Hembree Marsh 6/23/2009 12:00 PM Red-spotted newt N. viridescens viridescens 95.9 51.1 6.2 MT 35.9445/ -84.3456 Hembree Marsh 6/23/2009 12:00 PM Red-spotted newt N. viridescens viridescens 102.9 47.3 5
MT 35.9445/ -84.3456 Hembree Marsh 6/23/2009 12:00 PM Red-spotted newt N. viridescens viridescens 87.9 51.3 3.4 MT 35.9445/ -84.3456 Hembree Marsh 6/23/2009 12:00 PM Northern water snake Nerodia sipedon sipedon 50 MT 35.9445/ -84.3456 Hembree Marsh 6/25/2009 2:00 PM Pickerel frog Rana palustris 60.09 18 VES 35.954018 / 84.382447 Rainy Knob 6/25/2009 2:00 PM Cave salamander Eurycea lucifuga 63.8 30.03 0.9 VES 35.954018 / 84.382447 Rainy Knob 6/25/2009 2:00 PM Green frog Rana clamitans melanota 36.3 5.7 VES 35.954018 / 84.382447 Rainy Knob 6/26/2009 12:30 PM Marbled/ larval Ambystoma opacum 45.9 24.7 0.08 MT 35.9445/ -84.3456 Hembree Marsh 6/26/2009 12:30 PM Marbled/ larval Ambystoma opacum 51.3 25.7 1.2 MT 35.9445/ -84.3456 Hembree Marsh 6/26/2009 12:30 Marbled/ larval Ambystoma opacum 50.07 27.3 1.2 MT 35.9445/ -84.3456 Hembree Marsh 6/26/2009 12:30 PM Marbled/ larval Ambystoma opacum 41.6 23.7 0.09 MT 35.9445/ -84.3456 Hembree Marsh 6/26/2009 12:30 PM Marbled/ larval Ambystoma opacum 54.3 30.04 1.6 MT 35.9445/ -84.3456 Hembree Marsh 6/26/2009 12:30 PM Marbled/ larval Ambystoma opacum 51.1 26.4 1.4 MT 35.9445/ -84.3456 Hembree Marsh 6/26/2009 12:30 PM Marbled/ larval Ambystoma opacum 39.4 23 1
MT 35.9445/ -84.3456 Hembree Marsh 6/26/2009 12:30 PM Marbled/ larval Ambystoma opacum 46.6 25.7 1.2 MT 35.9445/ -84.3456 Hembree Marsh 6/26/2009 12:30 PM Marbled/ larval Ambystoma opacum 43.9 24.8 0.9 MT 35.9445/ -84.3456 Hembree Marsh 6/26/2009 12:30 PM Marbled/ larval Ambystoma opacum 50.6 28.2 1.4 MT 35.9445/ -84.3456 Hembree Marsh 6/26/2009 12:30 PM Red-spotted newt N. viridescens viridescens 94.3 41.5 4.2 MT 35.9445/ -84.3456 Hembree Marsh 6/26/2009 2:00 PM Pseudacris 27.2 1.1 MT 35.915208/ 84.399810 Freels Bend Pond 1 6/26/2009 2:00 PM Rana 87.2 30.08 4.9 MT 35.915208/ 84.399810 Freels Bend Pond 1 6/26/2009 2:00 PM Rana 75.6 29 5.1 MT 35.915208/ 84.399810 Freels Bend Pond 1 6/26/2009 2:00 PM Green frog Rana clamitans melanota 35.4 5.1 MT 35.915208/ 84.399810 Freels Bend Pond 1 6/26/2009 2:00 PM Green frog Rana clamitans melanota 36.1 3.4 MT 35.915208/ 84.399810 Freels Bend Pond 1 6/30/2009 1:30 PM Spotted dusky D. fuscus conanti 85.2 42.7 3.6 VES 35.9798/-84.2794 Walker Branch 6/30/2009 1:30 PM Spotted dusky D. fuscus conanti 32 17.8 0.3 VES 35.9798/-84.2794 Walker Branch 6/30/2009 1:30 PM Two lined salamander Eurycea cirrigera 44.9 23 0.4 VES 35.9798/-84.2794 Walker Branch 6/30/2009 1:30 PM Spotted dusky D. fuscus conanti 99.2 48.7 4
VES 35.9798/-84.2794 Walker Branch 6/30/2009 1:30 PM Northern dusky D. fuscus fuscus 66.1 30.4 0.9 VES 35.9798/-84.2794 Walker Branch 7/1/2009 2:00 PM Marbled salamander Ambystoma opacum 48.4 24.8 0.8 PF 35.9445/ -84.3456 Hembree Marsh 7/1/2009 2:00 PM Marbled salamander Ambystoma opacum 46.4 25.1 0.6 PF 35.9445/ -84.3456 Hembree Marsh 7/1/2009 2:00 PM Marbled salamander Ambystoma opacum 49.5 26.3 0.9 PF 35.9445/ -84.3456 Hembree Marsh 7/2/2009 1:30 PM Marbled/ larval Ambystoma opacum 50.4 27.5 1.1 MT 35.9445/ -84.3456 Hembree Marsh 7/2/2009 1:30 PM Marbled/ larval Ambystoma opacum 54.9 28.8 1.4 MT 35.9445/ -84.3456 Hembree Marsh 7/2/2009 1:30 PM Marbled/ larval Ambystoma opacum 45.6 24 1.1 MT 35.9445/ -84.3456 Hembree Marsh 7/2/2009 1:30 PM Marbled/ larval Ambystoma opacum 49.8 25 1
MT 35.9445/ -84.3456 Hembree Marsh 7/2/2009 1:30 PM Marbled/ larval Ambystoma opacum 52.5 29.6 1.2 MT 35.9445/ -84.3456 Hembree Marsh 7/2/2009 1:30 PM Marbled/ larval Ambystoma opacum 49.3 27.4 1.1 MT 35.9445/ -84.3456 Hembree Marsh 7/2/2009 1:30 PM Marbled/ larval Ambystoma opacum 50.03 29.4 0.9 MT 35.9445/ -84.3456 Hembree Marsh 7/2/2009 1:30 PM Marbled/ larval Ambystoma opacum 51.4 26.6 1.4 MT 35.9445/ -84.3456 Hembree Marsh 7/2/2009 1:30 PM Red-spotted newt N. viridescens viridescens MT 35.9445/ -84.3456 Hembree Marsh 7/6/2009 9:30 AM Northern brown snake Storeria dekayi dekayi 228.6 177.8 4.6 TIN 35.980686 / 84.211110 Solway/ Lynard Skynard pond 7/6/2009 12:30 PM Ringneck snake Diadophis punctatus edwardsii 285.75 215.9 4.6 CB 35.9537/-84.2847 Bearden Creek 7/6/2009 1:30PM Pickerel frog Rana palustris 51.5 15.6 VES 35.9537/-84.2847 Bearden Creek 7/6/2009 1:30 PM Northern dusky D. fuscus fuscus 45.8 24.5 0.4 VES 35.9537/-84.2847 Bearden Creek 7/6/2009 1:30 PM Two lined salamander Eurycea cirrigera 58.6 30.5 0.8 VES 35.9537/-84.2847 Bearden Creek 7/7/2009 3:15 PM Ringneck snake Diadophis punctatus edwardsii 304.8 234.95 6.9 CB 35.9445/ -84.3456 Hembree Marsh 7/8/2009 10:30 AM Spotted dusky D. conanti 75.55 34.05 0.09 VES 35.9640/ -84.3490 North HW Cove/Natural Area
D-16 Table D-3 (continued)
Date Time Species Scientific name Total SVL Wt.
Methoda Lat./Long.
Area 7/8/2009 10:30 AM Spotted dusky D. conanti 79.2 35.1 1.6 VES 35.9640/ -84.3490 North HW Cove/Natural Area 7/8/2009 10:30 AM Spotted dusky D. conanti 72.9 33 1.2 VES 35.9640/ -84.3490 North HW Cove/Natural Area 7/8/2009 10:30 AM Spotted dusky D. conanti 57.4 29.5 1.25 VES 35.9640/ -84.3490 North HW Cove/Natural Area 7/8/2009 10:30 AM Spotted dusky D. conanti 33.2 18.6 0.2 VES 35.9640/ -84.3490 North HW Cove/Natural Area 7/8/2009 10:30 AM Spotted dusky D. conanti 30.4 15.3 0.2 VES 35.9640/ -84.3490 North HW Cove/Natural Area 7/8/2009 10:30 AM Spotted dusky D. conanti 28.2 19.7 0.2 VES 35.9640/ -84.3490 North HW Cove/Natural Area 7/8/2009 10:30 AM Spotted dusky D. conanti 39.05 20.2 0.4 VES 35.9640/ -84.3490 North HW Cove/Natural Area 7/8/2009 10:30 AM Spotted dusky D. conanti 28.9 17.2 0.3 VES 35.9640/ -84.3490 North HW Cove/Natural Area 7/8/2009 10:30 AM Desmognathus Desmognathus 38.5 19.3 0.3 VES 35.9640/ -84.3490 North HW Cove/Natural Area 7/8/2009 10:30 AM Spotted dusky D. conanti 78.7 39.1 1.7 VES 35.9640/ -84.3490 North HW Cove/Natural Area 7/8/2009 10:30 AM Spotted dusky D. conanti 90.4 43.9 3.8 VES 35.9640/ -84.3490 North HW Cove/Natural Area 7/8/2009 10:30 AM Spotted dusky D. conanti 108.1 50.4 3.6 VES 35.9640/ -84.3490 North HW Cove/Natural Area 7/8/2009 12:00 PM Spotted salamander Ambystoma maculatum 40.5 22.4 0.6 VES 35.954018 / 84.382447 Amphibian Site 5 7/8/2009 12:00 PM Eurycea 39.9 20.7 0.5 VES 35.954018 / 84.382447 Amphibian Site 5 7/9/2009 10:30 AM Desmognathus spp.
46.7 23.4 0.1 VES 35.9537/-84.2847 Bearden Creek 7/9/2009 10:30 AM Desmognathus spp.
35.8 21.5 0.2 VES 35.9537/-84.2847 Bearden Creek 7/9/2009 10:30 AM Spotted dusky D. conanti 45.2 22.7 0.1 VES 35.9537/-84.2847 Bearden Creek 7/9/2009 10:3 AM Spotted dusky D. conanti 59.4 26.1 1.1 VES 35.9537/-84.2847 Bearden Creek 7/9/2009 10:30 AM Spotted dusky D. conanti 89.9 45.4 3.2 VES 35.9537/-84.2847 Bearden Creek 7/9/2009 10:30 AM Spotted dusky D. conanti 74.6 40.02 2.2 VES 35.9537/-84.2847 Bearden Creek 7/9/2009 10:30 AM Northern dusky D. fuscus 110.2 49.2 4.1 VES 35.9537/-84.2847 Bearden Creek 7/9/2009 10:30 AM Spotted dusky D. conanti 77.5 34.9 1
VES 35.9537/-84.2847 Bearden Creek 7/9/2009 10:30 AM Spotted dusky Desmognathus spp.
27.9 13.3 0.1 VES 35.9537/-84.2847 Bearden Creek 7/9/2009 2:00 PM Spotted dusky D. conanti 43.9 18.8 0.2 VES 35.9640/ -84.3490 Mesophytic Forest 7/9/2009 2:00 PM Spotted dusky D. conanti 31 16.9 0.2 VES 35.9640/ -84.3490 Mesophytic Forest 7/9/2009 2:00 PM Spotted dusky D. conanti 41.8 20.5 0.1 VES 35.9640/ -84.3490 Mesophytic Forest 7/9/2009 2:00 PM Spotted dusky D. conanti 38.2 29.3 0.2 VES 35.9640/ -84.3490 Mesophytic Forest 7/9/2009 2:00 PM Northern dusky D. fuscus 37.8 27.6 1
VES 35.9640/ -84.3490 Mesophytic Forest 7/9/2009 2:00 PM Spotted dusky D. conanti 90.01 38.4 2.2 VES 35.9640/ -84.3490 Mesophytic Forest 7/9/2009 2:00 PM Spotted dusky D. conanti 76.1 32.6 1.2 VES 35.9640/ -84.3490 Mesophytic Forest 7/9/2009 3:00 PM Spotted dusky D. conanti 30.01 17.3 0.2 VES 35.9640/ -84.3490 Mesophytic Forest 7/9/2009 3:00 PM Spotted dusky D. conanti 41 21.3 0.1 VES 35.9640/ -84.3490 Mesophytic Forest 7/9/2009 3:00 PM Northern dusky D. fuscus 99.1 35.6 2.6 VES 35.9640/ -84.3490 Mesophytic Forest 7/9/2009 3:00 PM Spotted dusky D. conanti 37.1 19.2 0.1 VES 35.9640/ -84.3490 Mesophytic Forest 7/9/2009 3:00 PM Spotted dusky D. conanti 37.3 17.05 0.2 VES 35.9640/ -84.3490 Mesophytic Forest 7/9/2009 3:00 PM Spotted dusky D. conanti 36.6 18.9 0.2 VES 35.9640/ -84.3490 Mesophytic Forest 7/9/2009 3:00 PM Northern red P. ruber 49.5 29.3 1.2 VES 35.9640/ -84.3490 Mesophytic Forest 7/9/2009 3:00 PM Northern dusky D. fuscus 60.05 31.6 1
VES 35.9640/ -84.3490 Mesophytic Forest 7/9/2009 3:00 PM Spotted dusky D. conanti 30.05 16.7 0.4 VES 35.9640/ -84.3490 Mesophytic Forest 7/9/2009 3:00 PM Spotted dusky D. conanti 36.4 21.8 0.2 VES 35.9640/ -84.3490 Mesophytic Forest 7/9/2009 3:00 PM Northern dusky D. fuscus 76.1 31.9 1
VES 35.9640/ -84.3490 Mesophytic Forest 7/9/2009 3:00 PM Northern dusky D. fuscus 58.7 29.2 1
VES 35.9640/ -84.3490 Mesophytic Forest 7/9/2009 3:00 PM Spotted dusky D. conanti 63.5 32.1 1.2 VES 35.9640/ -84.3490 Mesophytic Forest 7/9/2009 3:00 PM Spotted dusky D. conanti 67.4 30.05 1.2 VES 35.9640/ -84.3490 Mesophytic Forest 7/14/2009 10:00 AM Four toed salamander Hemidactylium scutatum 78.2 30.06 1.4 VES 35.954181/84.302790 SNS 7/17/2009 10:00 AM Cope's gray treefrog VES 35.954181/84.302790 SNS 7/17/2009 11:00 AM Cumberland slider Trachemys scripta troostii 1620 HN 35.9160/84.40067 Beaver Ponds ETTP 7/17/2009 11:30 AM Snapping turtle Chelydra serpentina 22680 HN 35.9160/84.40067 Beaver Ponds ETTP
D-17 Table D-3 (continued)
Date Time Species Scientific name Total SVL Wt.
Methoda Lat./Long.
Area 7/17/2009 11:30 AM Snapping turtle Chelydra serpentina 9071.
8 HN 35.9160/84.40067 Beaver Ponds ETTP 7/17/2009 11:30 AM Painted turtle Chrysemys picta HN 35.9160/84.40067 Beaver Ponds ETTP 7/17/2009 11:30 AM Cumberland slider Trachemys scripta troostii HN 35.9160/84.40067 Beaver Ponds ETTP aAbbrevations:
CO: cover object DN: dip net HN: hoop net MT: minnow trap PF: pitfall trap VES: visual encounter survey
APPENDIX E.
CLINCH RIVER ENVIRONMENTAL STUDIES ORGANIZATION (CRESO) RESULTS
E-3 Table E.1 Solway and Freels Bend turtle inventory/monitoring summary, 2007-2008 Captures n
Length (cm)
Weight (g)
Total Individual Male Female Mean Range Mean Range Total Male Female Total Male Female Total Male Female Male Female Painted turtlea 72 22 12 10 12.1 11.2 13.2 9.6-14.6 369.3 234.2 369.3 158-381 300-430 Cumberland slidera 50 21 10 10 18.57 16.7 20.5 14-22 1,080 940 1,468 501-1,417 1,097-1,800 Common snapping turtleb 31 12 7
5 31.3 35 26.8 24-38 32-38 24-29 7,929 10,079 4,920 6,790-12,200 3,530-5,990 Common musk turtleb 12 10 9
3 10.7 10 11 9.9-11.5 169 175 155 135-195 147-166 aPlastron length.
bCarapace length.
Table E.2 Solway and Freels Bend turtle inventory/monitoring summary, 2009 Captures n
Length (cm)
Weight (g)
Total Individual Male Female Mean Range Mean Range Total Male Female Total Male Female Total Male Female Male Female Painted turtlea 99 44 50 12.19 11.41 13.03 9.6-14.6 309.37 246.73 371.48 158-392 287-600 Cumberland slidera 65 26 38 18.27 15.71 20.38 5.2-22.4 1,199.92 790.81 1,506.75 34-1,417 375-1.955 Common snapping turtleb 46 33 4
30.41 30.99 26.7 24.2-37.5 24.2-37.4 24.2-29.1 6,749.3 7,399.6 3,680.99 3.96-12,900 3.96-5,990 Common musk turtleb 14 10 4
10.2 10.1 6.97 7.4-11.5 152.6 148.7 162.5 64-195.1 147-185 aPlastron length.
bCarapace length.
APPENDIX F.
REPTILES AND AMPHIBIANS OF THE OAK RIDGE RESERVATION
F-3 APPENDIX F.
REPTILES AND AMPHIBIANS OF THE OAK RIDGE RESERVATION Amphibians and Reptiles of the Oak Ridge Reservation a,b Family Scientific Name Common Name AMPHIBIANS: ORDER Caudata Ambystomatidae Ambystoma maculatum Spotted salamander Ambystoma opacum Marbled salamander Ambystoma tigrinum tigrinum Eastern tiger salamander Cryptobranchidae Cryptobranchus alleganiensis Hellbender Plethodontidae Aneides aeneus Green salamander Desmognathus fuscus Dusky salamander, Northern dusky salamander Desmognathus conanti Spotted dusky salamander Eurycea cirrigera Southern two-lined salamander, Two-lined salamander Eurycea longicauda Long-tailed salamander Eurycea lucifuga Cave salamander Gyrinophilus porphyriticus Spring salamander Hemidactylium scutatum Four-toed salamander Plethodon cinereus Eastern red-backed salamander, Red-backed salamander, Redback salamander Plethodon glutinosus Northern slimy salamander, Slimy salamander Pseudotriton montanus Mud salamander Pseudotriton ruber ruber Northern red salamander Salamandridae Notophthalmus viridescens viridescens Red-spotted newt AMPHIBIANS: ORDER Anura Bufonidae Bufo americanus americanus Eastern American toad Bufo fowleri Fowler's toad Hylidae Acris crepitans crepitans Eastern cricket frog, Northern cricket frog Hyla versicolor Gray treefrog Pseudacris crucifer crucifer Northern spring peeper Pseudacris feriarum feriarum Upland chorus frog Microhylidae Gastrophryne carolinensis Eastern narrow-mouthed toad Ranidae Rana catesbeiana American bullfrog, Bullfrog Rana clamitans melanota Green frog, Northern green frog Rana palustris Pickerel frog Rana pipiens Northern leopard frog Rana sphenocephala Southern leopard frog Rana sylvatica Wood frog Scaphiopodidae Scaphiopus holbrookii Eastern spadefoot
F-4 Amphibians and Reptiles of the Oak Ridge Reservation 1, 2 (Continued)
Family Scientific Name Common Name REPTILES: ORDER Testudines Chelydridae Chelydra serpentina serpentina Common snapping turtle Emydidae Chrysemys picta Painted turtle Graptemys geographica Common map turtle Graptemys ouachitensis Ouachita map turtle Graptemys pseudogeographica False map turtle Pseudemys concinna concinna Eastern river cooter Terrapene carolina carolina Eastern box turtle Trachemys scripta elegans Red-eared slider Trachemys scripta troostii Cumberland slider Kinosternidae Sternotherus minor Loggerhead musk turtle Sternotherus odoratus Common musk turtle Trionychidae Apalone spinifera spinifera Eastern spiny softshell turtle REPTILES: ORDER Squamata Colubridae Carphophis amoenus amoenus Eastern worm snake Cemophora coccinea Scarlet snake Coluber constrictor Black Racer, Racer Diadophis punctatus edwardsii Northern ringneck snake Elaphe guttata guttata Corn snake Elaphe obsoleta Rat snake, Texas rat snake Heterodon platirhinos Eastern hog-nosed snake Lampropeltis calligaster rhombomaculata Mole kingsnake Lampropeltis getula nigra Black kingsnake Lampropeltis triangulum triangulum Eastern milk snake Nerodia sipedon Northern watersnake Opheodrys aestivus Rough green snake, Rough greensnake Regina septemvittata Queen snake, Queensnake Storeria dekayi Brown snake, Dekay's brown snake, Dekay's brownsnake Storeria occipitomaculata occipitomaculata Northern red-bellied snake Thamnophis sirtalis sirtalis Common garter snake Virginia valeriae valeriae Eastern earth snake Phrynosomatidae Sceloporus undulatus hyacinthinus Northern fence lizard Scincidae Eumeces fasciatus Five-lined skink Eumeces inexpectatus Southeastern five-lined skink Eumeces laticeps Broad-headed skink Scincella lateralis Ground skink, Little brown skink Teiidae Cnemidophorus sexlineatus Six-lined racerunner Viperidae Agkistrodon contortrix mokasen Northern copperhead a Updated October 2008 b Taxonomic source: Integrated Taxonomic Information System, http://www.itis.gov
ORNL/TM-2009/296 INTERNAL DISTRIBUTION
- 1. Greg Byrd 50.
Harry Quarles
- 2. Jim Evans 51.
Scott Reasor 3-27. Neil Giffen 52.
Kelly Roy
- 28. Gary Jacobs 53.
Ernest Ryan, Jr.
- 29. Jerry Klein 54.
Mike Ryon 30-39. Pat Parr 55.
ORNL Office of Technical Information and Classification 40-49. Mark Peterson EXTERNAL DISTRIBUTION
- 56. Mary Blevins, Bechtel Jacobs, PO Box 4699, K-1580, MS 7169. Oak Ridge, TN 37830
- 57. John Byrd, Clinch River Environmental Studies Organization, 230 Speas Lane, Clinton, TN 37716
- 58. Claire Campbell, Furman University, P.O. Box 27734 3300 Poinsett Highway Greenville, SC 29613
- 59. Scott Dykes, Tennessee Wildlife Resources Agency, 3030 Wildlife Way Morristown, TN 37814
- 60. Bob English, Leaps Environmental Consulting, 6228 Les Waggoner Rd. Franklin, TN.
37067
- 61. Dr. Matthew Gray, University of Tennessee, 274 Ellington Plant Sciences Building, Knoxville, TN 37996-4563
- 62. Terri Killeffer, NBII, 105 Commerce Park Dr., Suite 10, Oak Ridge, TN 37831
- 63. Dr. Paul Kosnik, Tissue Genesis, Inc., 677 Ala Moana Boulevard Suite 1100 Honolulu, HI 96813 64-68. David Page, U.S. Department of Energy, P.O. Box 2001, MS-SE-32, Oak Ridge, TN 37831
- 69. Brittany Petersen, U.S. Fish and Wildlife, 2511 N 12th St, Monroe, La 71203
- 70. J. Warren Webb, 214 Park Lane Oliver Springs, TN 37840