ML18019A535

From kanterella
Jump to navigation Jump to search
Forwards SER & Eg&G Technical Evaluation Rept Re Conformance to Reg Guide 1.97.Instrumentation Provided for Meeting Recommendation Acceptable,Except for Accumulator Tank Level & Pressure Instrumentation
ML18019A535
Person / Time
Site: Harris  Duke Energy icon.png
Issue date: 01/21/1986
From: Buckley B
Office of Nuclear Reactor Regulation
To: Utley E
CAROLINA POWER & LIGHT CO.
Shared Package
ML18019A536 List:
References
RTR-REGGD-01.097, RTR-REGGD-1.097 NUDOCS 8601270398
Download: ML18019A535 (4)


Text

(

~

~ January 21, 1986 Docket No. 50-400

Subject:

Emergency

Response

Capability - Conformance to R.G. 1.97, Rev.

2 We are transmitting herewith our subject safety evaluation with its attach-

ment, EG&G Idaho, Inc., Technical Evaluation Report (TER) dated September 1985.

We find the instrumentation provided by Carolina Power and Light Company (CP&L) for meeting the recommendations of Regulatory Guide 1.97 acceptable except for the accumulator tank level and pressure instrumenta-tion.

The above cited safety evaluation will be included in a future supplemental report.

Sincerely, DISTRIBUTION:

'ocket No. 50-2613 ILee Local PDR ACRS (10)

Mr. E.

E. Utley, Senior Executive NRC PDR Tech.

Branch Vice President

'-'i2 R/F Gray File

,Power Supply and Engineering

& Construction TNovak Carolina Power and Light Company OELD Post Office Box 1551 EJordan

Raleigh, North Carolina 27602 BGrimes JPartlow

Dear Mr. Utley:

BBuckley

Enclosure:

As stated cc:

See attached list

<0+glnal SJgj~qd ~qy Bart C. Buckley, Project Manager PWR Project Directorate P2 Division of PWR Licensing-A Office of Nuclear Reactor Regulation FC

L NAME DATE:1/ I D
PM:P Q
D'P D-2
BCBuckley;bg L

/86

1/

/86

1/~

86 OFFICIAL RECORD COPY

~

~

~

~

~

~

860i270398 860i2il PDR ADOCK 05000400 F

PDRI

1 P

h I

P" a

Mr. E.

E. Utley Carolina Power 8 Light Company CC:

George F. Trowbridge, Esq.

Shaw, Pittman, Potts 5 Trowbridge 1800 M Street, NW Washington, DC 20036 Richard E. Jones, Esq.

Associate General Counsel Carolina Power 5 Light Company 411 Fayetteville Street Mall

Raleigh, North Carolina 27602 Jo Anne Sanford, Esq.

Special Deputy Attorney General State of North Carolina Post Office Box 629

Raleigh, North Carolina 27602 Thomas S. Erwin, Esq.

115 W. Morgan Street

Raleigh, North Carolina 27602 Resident Inspector/Harris NPS c/o U.S. Nuclear Regulatory Commission Route 1,

Box 315B New Hill, North Carolina 27562 Charles D. Barham, Jr.,

Esq.

Vice President 8 Senior Counsel Carolina Power 5 Light Company Post Office Box 1551

Raleigh, North Carolina 27602 Mr. John Runkle, Executive Coordinator Conservation Council of North Carolina 307 Granville Road Chapel Hill, North Carolina 27514 Mr. Wells Eddleman 806 Parker Street Durham, North Carolina 27701 Mr. George Jackson, Secretary Environmental Law Project School of Law, 064-A University of North Carolina Chapel Hill, North Carolina 27514 Shearon Harris Mr. Tt avis Payne, Esq.

723 W. Johnson Street Post Office Box 12643 Raleigh, North Carolina 27605 Mr. Daniel F.

Read CHANGE Post Office Box 2151

Raleigh, North Carolina 27602 Bradley W. Jones, Esq.

U.S. Nuclear Regulatory Commission Region II 101 Marietta Street Atlanta, Georgia 30303 Richard D. Wilson, M.D.

725 Hunter Street Apex, North Carolina 27502 Regional Administrator, Region II U.S. Nuclear Regulatory Commission 101 Marietta Street Suite 2900 Atlanta, Georgia 30303 Mr. Robert P. Gruber Executive Director Public Staff -

NCUC Post Office Box 991

Raleigh, North Carolina 27602 Dr. Linda Little Governor's Waste Management Board 513 Albemarle Building 325 North Salisbury Street
Raleigh, North Carolina 27611